Error Message not displaying full error msg in screen

Hi Frds,
Need to display the error message as my specified words.... . I have created a message class also... even though its not displaying mesage properly
My Message i passed here . R&D Material already exists.........

Hello Kabil,
If you use '&' then your message will be truncate in Status bar message. Best option would be use 'and' instead of '&' the your problem will be resolved.
Cheers,
Vadamalai A

Similar Messages

  • Error message not displayed in a pop up

    Hi ,
    I have a pop up screen in my web dynpro  with a input field and two buttons.
    i have a error message written in the WDDOBEFOREACTION method of my pop up window. But the message is not displayed on the window. But If the same is written in the event handler of the button click it is triggered.
    Please help me to display the message with the code in WDDOBEFOREACTION method  .
    The code is as below
    lo_nd_bp_data = wd_context->get_child_node( name = wd_this->wdctx_bp_data ).
    * get element via lead selection
      lo_el_bp_data = lo_nd_bp_data->get_element( ).
    * get single attribute
      lo_el_bp_data->get_attribute(
        EXPORTING
          name =  `BP_NUMBER`
        IMPORTING
          value = lv_bp_number ).
      CHECK lv_bp_number IS NOT INITIAL.
      IF zcl_rms_webdynpro_texts=>check_for_victim_bp( i_bp_number = lv_bp_number ) = abap_true.
    * get message manager
        DATA lo_api_controller     TYPE REF TO if_wd_controller.
        DATA lo_message_manager    TYPE REF TO if_wd_message_manager.
        DATA: lv_p1 LIKE syst-msgv1.
        lo_api_controller ?= wd_this->wd_get_api( ).
        CALL METHOD lo_api_controller->get_message_manager
          RECEIVING
            message_manager = lo_message_manager.
        lv_p1 = lv_bp_number.
    * report message
        CALL METHOD lo_message_manager->report_t100_message
          EXPORTING
            msgid                     = ZMSG_CLS
            msgno                     = '222'
            msgty                     = 'E'
            p1                        = lv_p1
            cancel_navigation         = abap_true
            enable_message_navigation = abap_true.
      ENDIF.
    Edited by: SAP LEARNER on Jan 5, 2012 1:37 PM

    have a error message written in the WDDOBEFOREACTION method of my pop up window. But the message is not displayed on the window. But If the same is written in the event handler of the button click it is triggered.
    strange..
    wddobeforeaction will trigger then event handler wil trigger then wddoafteraction will trigger.
    Did you put a break point in wddobeforeaction?
    Regards
    Srinivas

  • Error message not displayed - Downloading files in a table

    Hi!!!
    I'm following the guide to download files onDemand in a table, you can find that guide at:
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/b0e10426-77ca-2910-7eb5-d7d8982cb83f
    If found a problem with the guide: What would happen if there's an error while downloading or somenthing else? There the author doesn't explain how to show an error in the view.
    What I'd like to do is to show a error message in the view where the table is.
    I tried to add some code, but it doesn't finally show the error message.
    I have a method that generates the file and returns the path of the file in the context, so I can read it. It return boolean (true if the file was generated, false on the contray). That method is called executeZgav_Sf_Formulario_Sv_Input(nroEmpleado, nroViaje, morei, datosEspejo); and is working fine.
    I also have a static class that reads a file and returns the byte[] called: ManejoArchivos.getByteArrayFromResourcePath(wdContext.currentOutput_FormularioSVElement().getP_Path(), true);
    But if for example, the parameters are incorrect and the file cannot be generated, the method is supposed to show an error but is not displayed on the screen.
    I have some code after that which validates if the file could be read or not and returns the bytes of a prewritten PDF file with an error message.
    Added code:
              byte[] r = null;
              boolean continuar =
                   this.executeZgav_Sf_Formulario_Sv_Input(nroEmpleado, nroViaje, morei, datosEspejo);
              if (continuar)
                   try {
                        r =
                             ManejoArchivos.getByteArrayFromResourcePath(
                                  wdContext.currentOutput_FormularioSVElement().getP_Path(),
                                  true);
                   } catch (FileNotFoundException e) {
                        wdComponentAPI.getMessageManager().reportMessage(
                             IMessageData.ARCHIVO_NO_ENCONTRADO,
                             null,
                             true);
                   } catch (IOException e) {
                        wdComponentAPI.getMessageManager().reportMessage(IMessageData.PROBLEMA_IO, null, true);

    Hi Alejandro,
    Try This.
    try
    catch (FileNotFoundException e) {
    wdComponentAPI.getMessageManager().reportException("Given FileNotFoundException : "+e.getMessage(),true);
    catch (IOException ex) {
    wdComponentAPI.getMessageManager().reportException("Given IOException : "+ex.getMessage(),true);
    Re: How to display which exception Is Raised?
    Regards,
    Mithu

  • Why error messages not displaying in installed AIR app?

    Hi!
    Help me please understand how AIR handle errors. When I run air application from the Flex Builder and have some code that
    generates an error, a window appears with the error description, such this:
    TypeError: Error #1009: Cannot access a property or method of a null object reference.
        at MyApp/genError()[C:\FlexProjects\MyApp\src\MyApp.mxml:10876]
        at MyApp/___MyApp_Button92_click()[C:\FlexProjects\MyApp\src\MyAppmxml:10880]
    So I can see where error is occur and handle it. But when I release build the same app, run it, click the button that generate error, nothing happens, no error messages etc. So users can not catch bug even if it happens and can't reported it ...

    Thanks Ted!
    I will make every effort to debug errors at development time, but can not be 100% sure that they can all be found immediately. Can I set in the compiler option some parameter to 'true' for displaying error messages or something like that?

  • Error message not displaying when stock is zero

    Hi friends
    pls guide me how to solve , when ther is zero stock in the system for the particular item is not showing any error message , instead it is creating the delivery doc without any error message .
    pls tel me where would be the problem .....
    awaiting for the reply sooon ....
    Thanks in advance
    Mahi.

    Check Material Master, it it allows Negitive Stock. If yes then it will allow to process the Delivery Document.
    It is also possible that Availability Check is not maintained in Material Master ot settings of Availability Check.
    Regards,
    Rajesh Banka
    Reward points if helpful.

  • Imqadmin: No. of messages not displayed correctly in durable subs screen

    This question applies to the standalone platform edition of Message Queue v3.5 SP2 running on solaris.
    I have a number of durable subscribers connecting to a topic. Each & all subscriber have a selector set to filter the data.
    From imqadmin I can select the topic and bring up the broker destination properties. If I happen to have messages that have not been consumed (I halt my consumer code to test this), the count on the "basic" screen shows the current and correct number of messages waiting.
    If I drill down and go to the Durable Subscriptions screen, the number of messages for the durable subscriber with the relevant selector is always 0... and doesn't seem to reflect that there are messages that haven't been consumed. (Even though my code does see the data come in when I reconnect the consumer).
    Is this a bug in the imqadmin display or is there a reason why it can't display the message count correctly at the durable sub screen for consumers with a selector set?

    I don't think I'm seeing the same bug... in my app the producer and consumer are both active.
    Relevant information for this test:
    1) My producer and consumer are both active at the same time.
    2) My consumer is using a transacted session and it is also consuming messages synchronously
    3) I produce 250 messages and send them to my destination (a topic)
    4) For this test I force the consumer to fail on its handling of the data. Say it was trying to handle 50 messages - it rollsback the session and tries again. Therefore leaving 250 messages still in the topic.
    The result is that when I display the destination properties screen using imqadmin:
    1) The current number of messages count is displayed correctly as 250.
    2) However, the count for the durable subscriber with the correct selector is still showing 0.
    Once I allow the consumer to resume its work, all 250 messages are handled correctly by that consumer only and the count (in 1) is shown as 0.
    So the producer, consumer process works fine but the imqadmin gui seems a little confused.

  • JSF Error Message not displaying/popping up in clickToEdit table

    I have an entity object validation rule which displays a message when the validation fails. I have set the Validation Failure Severity as an Informational Warning. I do want to user to continue if he is happy to do so. Everything works fine when testing in the model project.
    Now, in the ViewController project when I add the View Object to a page as a af:table component the Warning message only comes up if the tables Behavior/EditingMode property is equal to editAll AND if the inputText Behavior/AutoSubmit property is false. It actually seems like this is the only time the validation is performed…
    If I change the tables Behavior/EditingMode property to be clickToEdit the warning message does not come up anymore?
    If I change the inputText Behavior/AutoSubmit property equal to true, then the warning messagewill not come up in ether of the editAll or clickToEdit table. A orange border will be displayed in the editAll table, but no message?
    What is the difference, and how can I get the warning message to be displayed when the table is clickToEdit table?
    I am using JDeveloper 11.1.1.3 PS2
    Thanks

    Hi
    Just to mention. It seems this issue was a bug in 11.1.1.3, and it is fixed in 11.1.1.4...
    I still don't know how to get around the problem in 11.1.1.3, but atleast it is working in the latest version.

  • [Solved] Grub not displaying menu, error messages from grub-mkconfig

    Hi I'm new
    I have (or rather, am trying to setup) a dual boot with Windows 8.1 and Arch, with each OS on separate SSDs.
    Windows 8.1 already installed, Arch installation (seems to have) has gone smoothly. However, when I remove the installation usb, and try to boot, I get a command line prompt:
    grub >_
    ...instead of a menu. I tried typing 'boot', but got 'you need to load the kernel first'. So I cannot access my arch installation without chrooting (or knowing how to compile the kernel in the command line, which I could not find after a lot of searching)
    I followed the documentation in the Beginner's Guide and the GRUB page for installing and configuring GRUB. This is UEFI (grub2), not BIOS (grub legacy).
    pacman -S grub efibootmgr
    grub-install --target=x86S64-efi --efi-directory=/boot --bootloader-id=arch_grub --recheck
    No error messages. I also installed os-prober for kicks. When I went to generate the config file (as recommended for beginners), I got a torrent of what I interpreted to be error messages, not just copacetic output:
    grub-mkconfig -o /boot/grub/grub.cfg
    resulted in:
    click this link for error messages
    (sorry about the image. I had to shutdown and reboot into my windows partition, since I still can't arch it up. If any/all of you have a better way to reproduce output and feel it pertinent, I'm all ears)
    so upon exiting chroot and rebooting, grub boots up to the above effect; no menu is displayed. And I am sad panda.
    Background Information:
    Partition scheme:
    /dev/sda1 - BIOS boot partition (I didn't read carefully, lol)
    /dev/sda2 - EFI System Partition - mounted to /mnt/boot when chrooting in
    /dev/sda3 - Root partition - mounted to /mnt/ when chrooting in
    /dev/sda4 - Home partition - mounted to /mnt/home when chrooting in
    The installation and configuration described above was done in chroot with the above partition scheme
    I originally had issues booting into UEFI mode with the arch iso (written to a usb stick for the initial install). The boot would hang at 'triggering uevents'. I ultimately fixed this by pressing 'e' in the bootloader menu (also grub, I believe) and prepended
    linux /boot/vmlinux-linux root=UUID=978e3e81-8048-4ae1-8a06-aa727458e8ff nomodeset nouveau.modeset=0
    It then (successfully triggered uevents? and) booted normally
    ALSO:
    This is a custom built pc.
    Hardware:
    intel i7 4930K
    ASUS Sabertooth X79 mobo
    ASUS GTX 780 Ti gpu
    ballistix sport DDR3 RAM (4 x 8 GB)
    3 x 128 GB SSD (ADATA P900)
    1 x 2 TB HDD (Toshiba, 7200 rpm)
    Hey, if you made it to the bottom of this post, I really appreciate you taking the time out of your day. Thank you!
    Last edited by Otsdarva (2014-06-09 03:22:25)

    I realized that since I was not using EFISTUB, I could not mount the ESP to /boot; it had to be /boot/efi. A quick remount-reinstall of grub, then rerunning grub-mkconfig solved the issue.
    Also, regarding WonderWoofy's suggestion: I learned by trying gummiboot that for whatever reason the kernel hadn't compiled properly when I ran
    pacstrap /mnt base base-devel
    Fixed via
    pacman -S linux
    Thanks for your help, everybody!

  • How to not display the error message ?

    hi everybody,
    I would like to know if it is possible to not display the error message in BO XI R2 when I try to refresh my reports ?
    (like "the query bla bla does not fetch any data...")
    Thanks for your help,
    Mario

    I've found this method to not display this error message but  the problem is that the prompt message when you refresh the report are not displayed:
    Has someone an idea ?
    Private Sub Document_BeforeRefresh(Cancel As Boolean)
    Application.Interactive = False
    End Sub
    Private Sub Document_AfterRefresh()
    Application.Interactive = True
    End Sub
    Edited by: Pascolo Mario on Oct 22, 2008 4:35 PM

  • UI error message when displaying Account Factsheet.

    When I view the factsheet in the UI I get the following error message:
    Cannot display view BSP_DLC_FS/factsheet of UI Component BSP_DLC_FS
    An exception has occurred
    Exception Class     CX_BSP_WD_INCORRECT_IMPLEMENT - Window 'SalesOrgSelectorWindow' is not defined in the component 'BP_FACTSHEET'
    Method:     CL_BSP_WD_COMPONENT_USAGE=>GET_INTERFACE_VIEW_CONTR
    Source Text Row:     28
    Cannot display view BSP_DLC_FS/factsheet of UI Component BSP_DLC_FS
    An exception has occurred
    Exception Class     CX_BSP_WD_RUNTIME_ERROR - View BP_FACTSHEET0002.SalesOrgSelectorWindow in component BSP_DLC_FS could not be bound
    Method:     CL_BSP_WD_VIEW_CONTROLLER=>BIND_VIEW
    Source Text Row:     165
    If I look at the BP_FACTSHEET component and the the window ''SalesOrgSelectorWindow' is defined and is active though.
    Can anyone make any suggestions as to the cause, or maybe things to check.
    Jason

    CRM 7.
    I was planning on performing a restore of the CRM dev system from the previous day, but then discovered that the Repository.xml was missing, or almost empty. This was the SAP standard .xml file, so I copied/pasted from our Sandpit CRM system, then everything worked. That may not have fixed the problem completely though, I'm just trying to see if there are any more issues. One of the symptoms was that when I entered the BSP component workbench there was no BOL Model Browser tab, but the Component structure browser and Runtime Repository editor was there.
    I'll check everything now and will ensure that all is okay, but on the plus side we can now display the factsheet in full within the UI with no errors. I'm beginning to think that perhaps CRM 7 is not as stable as I first thought. What action would blitz the Repository in this way and leave you with a non-working system I wonder. Also, at what point does the repository.xml get updated when changes are made, like when new viewsets added etc.
    Regards
    Jason

  • Error message while displaying a Workbook in Portal

    Hello,
    We have a Workbook with 5 Queries in ech sheet. When we open the Query from Portal it displays the error message that
    1. Query was changed! Characterisitc no longer exists
    2. Invalid filter on CUST_SD: Filter changed
    I opned the Workbook directly from Analyzer and it did not display the error message.
    Thus it seems to be a change required in Portal side or may be some property of the Workbook.
    Please let me know your opinion to fix the error.
    Regards,
    Nitin S.

    Can you define "sometimes" a bit more?
    Is it after a number of runs of a report?
    Is it on a particular report?
    Is it after you do certain operations on the report (paging, zooming, dill down, print, etc., etc.)?
    Can you duplicate the issue if you isolate the report to a new test app?
    Did you happen to notice if the issue existed prior to FP 3.5?
    Is this on your dev computer or a client computer?
    OS?
    Ludek
    Follow us on Twitter http://twitter.com/SAPCRNetSup
    Got Enhancement ideas? Try the [SAP Idea Place|https://ideas.sap.com/community/products_and_solutions/crystalreports]

  • No error message is displayed while deleting an attendee from a course.

    Hi Experts,
    Mu customer is facing problem while trying to delete an attendee from a course under Training and event management. The path he is following is right:
    1) In PSV1(Dynamic Attendance Menu)the employee is seen firmly booked in
    a course.
    2)Right-click on his name and select cancel
    3)Click the dustbin to remove
    But nothing is happening, neither the employee is getting moved from the course nor any error message is displaying giving us any indication of what can go wrong. Can you please suggest what can be the possible problem?
    Strangest thing is, this problem is occuring only for one employee.
    Thanks and Regards,
    Toa

    Hi Manoj,
    Thanks for your reply.
    That is the problem, no error message is showing. When the delete button is pressed, neither the attendee is getting deleted nor any error message is displaying as of why the deletion is not occuring.
    FYI: The employee is not locked.
    Thanks,
    Toa

  • Photoshop Elements 10 will not open.  I get Error message that says "Runtime Error!" and closes.  What do I do?

    Help.  Photoshop Elements 10 will not open.  I get Error message that says "Runtime Error!" and closes. What do I do?  What does it mean?  I bought Elements 10 at a retail store.  It did work for a while.

    Hi,
    Can you post back with the following.
    1.  The full Model No. and Product No. of the notebook ( from the service tag underneath your notebook ) - see Here for a further explanation.
    2.  The full version of the operating system you are using ( ie Windows 7 32bit ).
    Regards,
    DP-K
    ****Click the White thumb to say thanks****
    ****Please mark Accept As Solution if it solves your problem****
    ****I don't work for HP****
    Microsoft MVP - Windows Experience

  • Error messages are displayed when opening the RTV form.

    Hi All,
    While doing a return to vendor the following error messages are displayed.
    1.Go to the Inventory Management --> Return to Vendor screen.
    2. In Action Drop down select ‘New’ and click on OK
    3. A series of errors are encountered.
    4. A warning message as [640+49> 688] and then click ‘OK’.
    5. Notice the error message”Multi view internal error: B_RTV_DETAIL.QTY_RETURNED:current_col_pos exceeds parameter defined maximum right position” and then click’ OK’.
    Can any one help me out in these?
    Thanks,
    Sushanth.D

    This is a coding issue in the form, maybe the number is too big for the box on the canvas.
    It looks also like a business issue is kicking off the error, the message [640+49> 688] looks like some units of stock etc. check, e.g. the returned quantity is larger than the stock on hand.
    File an SR with OracleSupport and/or open the UI's Form fmb code in Forms Developer.
    Multi View relates to an (quite old) OracleRetail (Retek) Forms pll library that enhances the Forms features, if my memory is not letting me down.
    Best regards,
    Erik

  • Error message "not digitally signed or not signed in the appropriate manner

    My computer keeps crashing and I discovered that it is not recognizing a hardware device.  The device is the printer.  When I check further, it asks for driver updates and when I try to do that, I get an error message "not digitally signed or not signed in the appropriate manner.  
    I have no idea how to fix this since I am the administrator and I have an HP laptop too.  Any help is great.
    Thanks,
    Sonja

    Welcome to the community, Sonja! Aka @sonipsl 
    I have personally ran into the error message you are receiving before that states "not digitally signed or not signed in the appropriate manner", and I had posted a solution to it as well. I would like for you to see the steps that had fixed the problem in my first link below. You will notice that you will have to download the correct drivers for your printer, the Photosmart B210a model, and that link is also below.
    Click this link and try the steps in my post: Solution! Re: Getting Error when updating Driver for D110a
    This is link to get your drivers for your printer model: HP Photosmart Full Feature Software and Drivers
    I hope this does the trick! Please write me back to let me know the outcome
    Enjoy the rest of your Tuesday
    R a i n b o w 7000I work on behalf of HP
    Click the “Kudos Thumbs Up" at the bottom of this post to say
    “Thanks” for helping!
    Click “Accept as Solution” if you feel my post solved your issue, it will help others find the solution!

Maybe you are looking for