ACE Module
Basically we have a running ACE context which works however we are using natting and we have some applications complaining that they can't see the source address of things. So I created a whole new context with the following config but I have the problem of when the client is on the server side network the traffic never makes it there.
ACE1/10.0.0.0_Network# sho run
Generating configuration....
access-list ALL line 8 extended permit ip any any
rserver host CE-565-1
ip address 10.0.2.83
inservice
serverfarm host Content_Engine_SF
rserver CE-565-1
inservice
class-map match-all Content_Engine_VIP
2 match virtual-address 10.0.18.101 any
class-map type management match-any Remote_Management
2 match protocol http any
3 match protocol icmp any
4 match protocol telnet any
5 match protocol ssh any
policy-map type management first-match rmt_mgt_policy
class Remote_Management
permit
policy-map type loadbalance first-match Content_Engine_VIP-l7slb
class class-default
serverfarm Content_Engine_SF
policy-map multi-match int18
class Content_Engine_VIP
loadbalance vip inservice
loadbalance policy Content_Engine_VIP-l7slb
loadbalance vip icmp-reply active
access-group input ALL
interface vlan 3
description Server_Side
ip address 10.0.3.240 255.255.254.0
mac-sticky enable
no shutdown
interface vlan 18
description Client Side Network
ip address 10.0.18.251 255.255.255.0
mac-sticky enable
service-policy input int18
no shutdown
ip route 0.0.0.0 0.0.0.0 10.0.18.1
if I telnet to the vip from my machine 172.16.6.222 it works fine. If I telnet from 10.0.18.30 it works fine. However when I telnet from a machine on the vlan 3 10.0.2.188 it does not work. I would have thought the mac-sticky option would work but it seems to be doing nothing. Any ideas with out using a NAT pool would be great so we can see the originating IP Address.
If you are initiating traffic from serverA to a vip that load balances to serverB in that same vlan you will have an asymmetric flow. ServerA is on the same vlan as serverB. Since both servers are in the same subnet, ServerB will ARP for serverA address and send the response directly to serverA. The traffic will never make it back to the ACE. There are a few things you can do:
1. Use NAT to ensure the return traffice makes it back to ACE.
2. Insert HTTP header with client IP address. This only works for HTTP traffic and your application must be able to recognize this header for logging.
http://www.cisco.com/en/US/docs/interfaces_modules/services_modules/ace/v3.00_A1/configuration/slb/guide/classlb.html#wp1040008
3. Use Direct Server Return (DSR). This feature has been committed to ACE 2.0. This will require the servers to be L2 adjacent to the ACE module and you will need to configure the VIP address as a loopback address on the server. Here is CSM documentation that lists some of the limitations with DSR:
http://www.cisco.com/en/US/docs/interfaces_modules/services_modules/csm/4.2.x/configuration/guide/netwcsm.html#wp1065827
Similar Messages
-
A problem with ACL in the class-map on the ACE module
Hi all,
I configured the following on the ACE module:
object-group network test
host 192.168.1.21
host 192.168.1.22
host 192.168.1.23
object-group service port
tcp eq www
tcp eq 8080
access-list T line 8 extended permit object-group port object-group test any
I tried to configure a class-map for matching this ACL:
ACE-4710-2/Lab-OPT-11(config)# class-map match-any TEST_C
ACE-4710-2/Lab-OPT-11(config-cmap)# match access-list T
Error: Cannot associate acl having object-group ACEs in class-map.
So couldn't I configure the class-map by using ACL with object-groups involved? Is it the bug or the normal behaviour? Because the customer uses object-groups in ACLs and he has to configure ACL without object-groups for the traffic classification. It is horrible.
Thank you
RomanHi Roman,
I'm afraid it's the expected behavior. You cannot use an ACL with object-groups inside a class-map.
Regards
Daniel -
How to Virtual IP configuration in ACE module?
Hi,
I am in the process of configuring load balancing on ACE module but struggling to configure virtual IP address for ACE module.
I'm working on ACE30 module and using software version A5 (1.2). ACE module is in slot of Catalyst 6504 switch.
Can anybody please post the steps/commands to perform this activity? An early response would be appreciated.
Regards,
Rachit.Hi Rachit,
Here is a basic configuration example:
access-list Allow_Access line 10 extended permit ip any any
rserver host test
ip address 10.198.16.98
inservice
rserver host test2
ip address 10.198.16.93
inservice
serverfarm host test
rserver test 80
inservice
rserver test2 80
inservice
sticky http-cookie test group2
cookie insert
serverfarm test
class-map match-all VIP
2 match virtual-address 10.198.16.122 tcp eq www
policy-map type loadbalance first-match test
class class-default
sticky-serverfarm group1
policy-map multi-match clients
class VIP
loadbalance vip inservice
loadbalance policy test
loadbalance vip icmp-reply active
nat dynamic 1 vlan 112
interface vlan 112
ip address 10.198.16.91 255.255.255.192
access-group input Allow_Access
nat-pool 1 10.198.16.122 10.198.16.122 netmask 255.255.255.192 pat
service-policy input NSS_MGMT
service-policy input clients
no shutdown
ip route 0.0.0.0 0.0.0.0 10.198.16.65
Here is the configuration guide:
http://tools.cisco.com/squish/101AD
Cesar R -
hi,
Is it possible to load balance VIP hits on two ACE Modules in an active/active configuration. Or is it that only per FT group only single context could be active.
Regards.You can have 1 context active on one ACE and the other context active on the other ACE.
If you have 2 Vip, you can have 1 vip belonging to one context and the other vip belonging to the other context.
Like this, you split the traffic between the 2 devices which allows you to handle more traffic than what 1 device could normally do.
If one device can handle all your traffic, I prefer to only have 1 active unit and 1 standby.
Easier to implement and troubleshoot.
Gilles. -
Reuse of context in ACE module
Hi all, just have a question about som reuse of resources in a ACE module context. I don't want to make a new context, and can reuse most of the existing configuration in one of my context. The config is not complex and difficult, but I'm not sure if I can do this.
The primary goal is to loadbalance 2 webservers with a new vip, new serverfarm, stickygroup, policy-map and different nat-pool.
Since I haven't decided the ip addresses to be used, they are just xx in the config below.
The changes I want to implement are in bold. Will this work for me?
probe http WEBGUI_D2
description Probe for http mot webgui
interval 10
passdetect interval 10
passdetect count 1
request method get url /D2/auth/login.aspx
expect status 200 302
header User-Agent header-value "IDENTITY"
rserver host cwi003
description content server logon
ip address 10.163.22.27
inservice
rserver host cwi004
description content server logon
ip address 10.163.22.28
inservice
rserver host cwi503
description content server logon 2
ip address 10.163.22.23
inservice
rserver host cwi504
description content server logon 2
ip address 10.163.22.24
inservice
serverfarm host SF_LOGON_D2
probe WEBGUI_D2
rserver cwi003 80
inservice
rserver cwi004 80
inservice
serverfarm host SF_LOGON2_D2
probe WEBGUI_D2
rserver cwi503 80
inservice
rserver cwi504 80
inservice
sticky ip-netmask 255.255.255.255 address source STICKYGROUP1
timeout 20
replicate sticky
serverfarm SF_LOGON_D2
serverfarm SF_LOGON2_D2
class-map match-all VS_LOGON_D2
3 match virtual-address 10.163.22.13 any
class-map match-all VS_LOGON2_D2
3 match virtual-address 10.163.22.xx any
policy-map type loadbalance first-match PM_ONE_ARM_LB
class class-default
sticky-serverfarm STICKYGROUP1
policy-map multi-match PM_ONE_ARM_MULTI_MATCH
class VS_LOGON_D2
loadbalance vip inservice
loadbalance policy PM_ONE_ARM_LB
nat dynamic 5 vlan 1240
class VS_LOGON2_D2
loadbalance vip inservice
loadbalance policy PM_ONE_ARM_LB
nat dynamic 6 vlan 1240
interface vlan 1240
description Client_server
ip address 10.163.22.11 255.255.255.0
peer ip address 10.163.22.12 255.255.255.0
access-group input INBOUND
nat-pool 5 10.163.22.14 10.163.22.17 netmask 255.255.255.192 pat
nat-pool 6 10.163.22.xx 10.163.22.xx netmask 255.255.255.192 pat
service-policy input PM_ONE_ARM_MULTI_MATCH
no shutdown
ip route 0.0.0.0 0.0.0.0 10.163.22.1
BR
GeirThanks for your reply.
Hope I understand you correct. This sould be the config I need to paste into the existing context.
rserver host cwi503
description content server logon 2
ip address 10.163.22.23
inservice
rserver host cwi504
description content server logon 2
ip address 10.163.22.24
inservice
serverfarm host SF_LOGON2_D2
probe WEBGUI_D2
rserver cwi503 80
inservice
rserver cwi504 80
inservice
sticky ip-netmask 255.255.255.255 address source STICKYGROUP2
timeout 20
replicate sticky
serverfarm SF_LOGON2_D2
class-map match-all VS_LOGON2_D2
3 match virtual-address 10.163.22.xx any
policy-map type loadbalance first-match PM_ONE_ARM_LB2
class class-default
sticky-serverfarm STICKYGROUP2
policy-map multi-match PM_ONE_ARM_MULTI_MATCH
class VS_LOGON2_D2
loadbalance vip inservice
loadbalance policy PM_ONE_ARM_LB2
nat dynamic 6 vlan 1240
interface vlan 1240
nat-pool 6 10.163.22.xx 10.163.22.xx netmask 255.255.255.192 pat
Br
Geir -
ACE module - Qos - set ip tos #
All,
Trying to mark traffic to/from L4 rules in the ACE.
Documentation (like always) says it's really easy. Mark traffic by using the "set ip tos <value>" command in Policy/Class configuration. Ok, so I do this, set ip tos 24.
Enable qos globally on the 6500 host, but don't see the traffic being marked.
sh mls qos says that packets are being modified by module 5 (ACE)
But I never see the tos value in any of my captures either via netflow from the host 6500, or at the firewall one hop away.
sh mls qos:
QoS is enabled globally
Policy marking depends on port_trust
QoS ip packet dscp rewrite enabled globally
Input mode for GRE Tunnel is Pipe mode
Input mode for MPLS is Pipe mode
QoS Trust state is CoS on the following interface:
Te3/1
QoS Trust state is DSCP on the following interface:
Gi2/3
Vlan or Portchannel(Multi-Earl) policies supported: Yes
Egress policies supported: Yes
----- Module [5] -----
QoS global counters:
Total packets: 207147888661
IP shortcut packets: 0
Packets dropped by policing: 0
IP packets with TOS changed by policing: 2663386
IP packets with COS changed by policing: 4889352
Non-IP packets with COS changed by policing: 0
MPLS packets with EXP changed by policing: 0
Can someone explain to me what I've got wrong here? Is the ACE simply marking traffic destined for the servers behind it and not the return traffic? Am I missunderstanding something?Well... hopefully someone knows how to classify traffic coming from the ACE.
I've given up on using the ACE to mark traffic as I'm fairly certain it won't do it. At least not the way I want.
However, now I've taken to marking ingress on the rserver switch ports... which has resulted in a partially sucessful solution. Problem is, "partially" successful.
You'll have a bunch of little conversations like this with no tos value full of push-acks:
10:29:53.527526 207.161.222.68.2828 > 205.200.114.228.http: P 2954:3455(501) ack 203152 win 65535 (DF)
10:29:53.527698 205.200.114.228.http > 207.161.222.68.2828: . ack 3455 win 32267
10:29:53.555271 207.161.222.68.2828 > 205.200.114.228.http: P 3455:3686(231) ack 203152 win 65535 (DF)
10:29:53.562676 205.200.114.228.http > 207.161.222.68.2828: P 203152:203784(632) ack 3686 win 32768
10:29:53.674758 207.161.222.68.2828 > 205.200.114.228.http: P 3686:4036(350) ack 203784 win 64903 (DF)
10:29:53.690853 205.200.114.228.http > 207.161.222.68.2828: P 203784:205244(1460) ack 4036 win 32768
10:29:53.690863 205.200.114.228.http > 207.161.222.68.2828: P 205244:206704(1460) ack 4036 win 32768
10:29:53.690871 205.200.114.228.http > 207.161.222.68.2828: P 206704:208164(1460) ack 4036 win 32768
10:29:53.690879 205.200.114.228.http > 207.161.222.68.2828: P 208164:209624(1460) ack 4036 win 32768
10:29:53.690887 205.200.114.228.http > 207.161.222.68.2828: P 209624:211084(1460) ack 4036 win 32768
10:29:53.690895 205.200.114.228.http > 207.161.222.68.2828: P 211084:212544(1460) ack 4036 win 32768
But then you'll see another conversation pop up with the correct markings
10:31:53.845287 205.200.114.228.http > 207.161.222.68.2828: . 32753:34213(1460) ack 1082 win 62808 (DF) [tos 0x48]
10:31:53.845298 205.200.114.228.http > 207.161.222.68.2828: . 34213:35673(1460) ack 1082 win 62808 (DF) [tos 0x48]
10:31:53.845306 205.200.114.228.http > 207.161.222.68.2828: . 35673:37133(1460) ack 1082 win 62808 (DF) [tos 0x48]
10:31:53.845313 205.200.114.228.http > 207.161.222.68.2828: . 37133:38593(1460) ack 1082 win 62808 (DF) [tos 0x48]
10:31:53.845321 205.200.114.228.http > 207.161.222.68.2828: . 38593:40053(1460) ack 1082 win 62808 (DF) [tos 0x48]
10:31:53.845328 205.200.114.228.http > 207.161.222.68.2828: . 40053:41513(1460) ack 1082 win 62808 (DF) [tos 0x48]
10:31:53.845335 205.200.114.228.http > 207.161.222.68.2828: . 41513:42973(1460) ack 1082 win 62808 (DF) [tos 0x48]
10:31:53.845343 205.200.114.228.http > 207.161.222.68.2828: . 42973:44433(1460) ack 1082 win 62808 (DF) [tos 0x48]
I think what's happening, is that the conversations full of the P-acks is the load balancer communicating directly with the client (i.e. LB pretending to be the server), whereas the marked traffic is "data only" which the load balancer isn't mangling (like it might/probably is doing with the p-acks) on it's way back to the client.
I also can't modify the configuration of the "virtual ten gig" interface that the 6500 uses as a connection to the ACE module, so can't mark traffic there either. And though I still have a couple of things to try, I don't believe I can do egress marking on a trunk from the 6500 either (connection to the firewalls).
So.... PLEASE... Anyone??? Ideas??? -
[UDP fast age support for ACE Module]
Hello,
I'm testing 2 ACE modules running A3.0.0 for DNS load balancing (UDP). We're testing this by using a DNS query generator that (always) seems to use the same UDP source port when originating these queries. At the moment, the ACE module is hardly doing any load-balancing.
It looks to me like, that because of this, the ACE believes it's the same session (connection) and doesn't really load-balance, so I started looking for a solution and found the fast-age udp feature. But, it seems this is not supported on my ACE modules. Can any one offer another solution and/or look at my config and see if there is another way to achieve load balancing in a testing environment when using a tool like the one I described?
(I put it that way because i believe in real life since queries come from different IP addresses and randomized udp ports, the ACE module will be just fine).
Thanks in advance!
c.Hi Carlos,
Correct. The 3.0(0) is really misleading. You need to start with the "A" - so you really have 1.6.3a installed.
The "show version" for V2 is slightly better -
system: Version A2(1.2) [build 3.0(0)A2(1.2)
Cathy -
Ace module dropping assymetric layer 2 connections
Hi we had a situation in where the ACE would randomly drop certain tcp connections, and all ICMP packets from a certain windows server. The server in question was using Transmit Load Balancing with Fault Tolerance.
The server has one Nic connected to Access switch1, and the other nic connected to Access switch2. Each access switch connects up to a pair of 6509's, which is active on Core1 on both switches.
I am guessing If the server sends on Nic 2, core1 knows it came in on the downstream trunk port to Switch2, it must reply to these packets based on the teamed mac of the layer 3 address(no idea who is arping for the destination - the ace?), and send them back out the downstream trunk port to switch1. The ace module is in transparent mode. When contacting a server on the other side of the ace, the ace drop packets that came from the second nic - and I am wondering how it "knows" that the return path is out of different downstream port. Does it share some kind of layer 2 RPF check with the 6500 ?
Please note there is no routing involved here. The destination server is just on another vlan on the same subnet, on the other side of the ace.Bryan,
As long as the server replies back to the ACE the client should only be commmunicating with the VIP address in either of your two examples.
In your first example the flow will look like this.
client > VIP after the ACE client > rserver
the reply would be
rserver > client after the ACE VIP > rserver
In your second example using client nat it will look like this
Client > VIP After ACE Natpool > rserver.
the reply would be
rserver > Nat-pool after ACE VIP > client.
The ACE by default will always nat the vip to the server ip unless you use the command "transparent" under the serverfarm. When using this command we send the packet to the MAC address of the server leaving the destination IP of the VIP. The server would need to have the VIP address configured under the loopback interface.
Regards
Jim -
Ace module in bridged mode with client nat
Could someone confirm whatever a NAT is supported for ACE-20 module, please?
Let me to explain technical details.
I do need to convert working CSM(SLB) config to ACE configuration and I am not quite sure
if the configuration below is correct. ACE module should be configured in bridge mode with two
vlans - vlan 36 (client) and vlan 436 (server) - bridged with interface bvi 36.
NAT on ACE configurad as "nat dynamic 1025 vlan 436" into corresponding
"policy-map type loadbalance"
Could you check two parts of configs and advise me if the ACE config is
properly converted from CSM and will be working in the same way (especialy for NAT).
Thank you in advance.
CSM config
=======
vlan 36 client
ip address 10.36.3.3 255.255.255.0 alt 10.36.3.4 255.255.255.0
gateway 10.36.3.1
vlan 436 server
ip address 10.36.3.3 255.255.255.0 alt 10.36.3.4 255.255.255.0
natpool WEB-MAIL 10.36.3.100 10.36.3.100 netmask 255.255.255.0
sticky 30 netmask 255.255.255.255 address source timeout 60
probe SHAREPOINT tcp
interval 30
failed 120
open 3
port 80
probe WEBMAIL-443 tcp
interval 5
failed 60
open 2
port 443
serverfarm WEBMAIL-443
nat server
nat client WEB-MAIL
predictor leastconns
real 10.36.3.101 443
inservice
real 10.36.3.102 443
inservice
probe WEBMAIL-443
serverfarm WEBMAIL-80
nat server
nat client WEB-MAIL
predictor leastconns
real 10.36.3.101 80
inservice
real 10.36.3.102 80
inservice
probe SHAREPOINT
vserver WEBMAIL-443
virtual 10.36.3.100 tcp https
serverfarm WEBMAIL-443
sticky 60 group 30
replicate csrp sticky
replicate csrp connection
persistent rebalance
inservice
vserver WEBMAIL-80
virtual 10.36.3.100 tcp www
serverfarm WEBMAIL-80
replicate csrp connection
persistent rebalance
inservice
ACE config
=======
probe tcp WEBMAIL-443
interval 5
open 2
passdetect interval 60
port 443
probe tcp SHAREPOINT
interval 30
open 3
passdetect interval 120
port 80
serverfarm host WEBMAIL-443
predictor leastconns
probe WEBMAIL-443
rserver 10-36-3-101 443
inservice
rserver 10-36-3-102 443
inservice
serverfarm host WEBMAIL-80
predictor leastconns
probe SHAREPOINT
rserver 10-36-3-101 80
inservice
rserver 10-36-3-102 80
inservice
class-map match-all WEBMAIL-80
match virtual-address 10.36.3.100 tcp eq www
class-map match-all WEBMAIL-443
match virtual-address 10.36.3.100 tcp eq https
sticky ip-netmask 255.255.255.255 address source 30
serverfarm WEBMAIL-443
replicate sticky
timeout 60
policy-map type loadbalance first-match WEBMAIL-80
class class-default
serverfarm WEBMAIL-80
nat dynamic 1025 vlan 436 serverfarm primary
policy-map type loadbalance first-match WEBMAIL-443
class class-default
sticky-serverfarm 30
nat dynamic 1025 vlan 436 serverfarm primary
parameter-map type http HTTP_ADV_OPT
persistence-rebalance
policy-map multi-match IFVLAN36-POLICY
class WEBMAIL-80
appl-parameter http advanced-options HTTP_ADV_OPT
loadbalance policy WEBMAIL-80
loadbalance vip inservice
loadbalance vip icmp-reply active
class WEBMAIL-443
appl-parameter http advanced-options HTTP_ADV_OPT
loadbalance policy WEBMAIL-443
loadbalance vip inservice
loadbalance vip icmp-reply active
interface vlan 36
bridge-group 36
service-policy input IFVLAN36-POLICY
mac-sticky enable
no shutdown
interface vlan 436
bridge-group 36
nat-pool 1025 10.36.3.100 10.36.3.100 netmask 255.255.255.0
no shutdown
interface bvi 36
ip address 10.36.3.3 255.255.255.0
peer ip address 10.36.3.4 255.255.255.0
no shutdownHello F.Makarenko-
You will want to use PAT while you do nat, so change the natpool configuration to this:
nat-pool 1025 10.36.3.100 10.36.3.100 netmask 255.255.255.0 pat
You also need to apply the nat like this:
policy-map multi-match IFVLAN36-POLICY
class WEBMAIL-80
appl-parameter http advanced-options HTTP_ADV_OPT
loadbalance policy WEBMAIL-80
loadbalance vip inservice
loadbalance vip icmp-reply active
nat dynamic 1025 vlan 436
class WEBMAIL-443
appl-parameter http advanced-options HTTP_ADV_OPT
loadbalance policy WEBMAIL-443
loadbalance vip inservice
loadbalance vip icmp-reply active
nat dynamic 1025 vlan 436
If you are going to build out a lot of classes, you can instead do source nat like this:
policy-map multi-match IFVLAN36-POLICY
class WEBMAIL-80
appl-parameter http advanced-options HTTP_ADV_OPT
loadbalance policy WEBMAIL-80
loadbalance vip inservice
loadbalance vip icmp-reply active
class WEBMAIL-443
appl-parameter http advanced-options HTTP_ADV_OPT
loadbalance policy WEBMAIL-443
loadbalance vip inservice
loadbalance vip icmp-reply active
class class-default
nat dynamic 1025 vlan 436
Regards,
Chris Higgins -
Hi,
I am trying to configure FT on ACE modules, with the following commands
ft interface vlan 20
ip address 172.16.20.1 255.255.255.252
peer ip address 172.16.20.2 255.255.255.252
no shutdown
ft peer 1
heartbeat interval 300
heartbeat count 10
ft-interface vlan 20
ft group 1
peer 1
priority 150
associate-context Admin
inservice
The moment I enter the command 'ft interface vlan 20', it gives a prompt that 'interface vlan20 is not associated with ft', how do I resolve this ? Do I need to enable something ?Hi have the following config which seems to be working fine for me... check your vlan20 interface is up
ft interface vlan 212
ip address 172.31.1.221 255.255.255.252
peer ip address 172.31.1.222 255.255.255.252
no shutdown
ft peer 1
heartbeat interval 300
heartbeat count 20
ft-interface vlan 212
ft group 2
peer 1
priority 50
peer priority 150
associate-context Admin
inservice
HQ-ACE1/Admin# sh int
vlan212 is up, administratively up
Hardware type is VLAN
MAC address is 00:23:5e:25:72:f1
Mode : routed
IP address is 172.31.1.221 netmask is 255.255.255.252
FT status is standby
Description:not set
MTU: 1500 bytes
Last cleared: never
Last Changed: Tue Sep 6 12:46:06 2011
No of transitions: 1
Alias IP address not set
Peer IP address is 172.31.1.222 Peer IP netmask is 255.255.255.252
Assigned from the Supervisor, up on Supervisor
8654909 unicast packets input, 735611030 bytes
1151150 multicast, 161 broadcast
0 input errors, 0 unknown, 0 ignored, 0 unicast RPF drops
13020418 unicast packets output, 1672055521 bytes
0 multicast, 163 broadcast
0 output errors, 0 ignored -
Simple SLB with the ACE Module
Hello,
i have some problems with a ACE module i am currently tesing.
I have a simple Serverfarm with two Servers.
But there seems to be some Problems with the Loadbalancing i not understand:
1) I use Round Robin, but the ACE seems to put me serval times to the same server. I notice this, because i have different content on both servers, also different URLs.
2) withz the show serverfarm statement the total connects do not increment.
switch/slb-c1# show serverfarm webfarm
serverfarm : webfarm, type: HOST
total rservers : 2
----------connections-----------
real weight state current total
---+---------------------+------+------------+----------+--------------------
rserver: web1
10.0.33.201:0 8 OPERATIONAL 0 0
rserver: web2
10.0.33.200:0 8 OPERATIONAL 0 0
switch/slb-c1# show service-policy L4_LB_VIP
Status : ACTIVE
Interface: vlan 300
service-policy: L4_LB_VIP
class: L4_VIP_CLASS
loadbalance:
L7 loadbalance policy: L7_SLB_POLICY
VIP Route Metric : 77
VIP Route Advertise : DISABLED
VIP ICMP Reply : ENABLED
VIP State: INSERVICE
curr conns : 0 , hit count : 15
dropped conns : 0
client pkt count : 10198 , client byte count: 420991
server pkt count : 23367 , server byte count: 34915173
I have attatched the Config.
Any Idea what is going on?what version do you have ?
I would recommend to run the very recent A1.4.
This is something that really should work.
Gilles. -
ACE Module Radius with ACS 4.2
Hi,
I am able to authenticate to my ACE modules via Radius, but when I login it does not give my Admin rights. Does anyone have a fix for this? My ACS admin has been working with TAC since last week to no avail.
John...You have to use a custom AV pair on TACACS server under user setup to make it work. ACE uses RBAC (role based Access Control) and for that you have to pass the context and User Role from Tacacs server to ACE to make it work.If there is no RBAC info is pushed from Tacacs server and user just get authenticated then the default role assigned by ACE is Network-Monitor.
Following steps (On tacacs server) will make it work
1. Select your user
2. goto tacas+ settings
3. Select " shell (exec)" checkbox
4. Select "custom attributes" checkbox
5. Type your context and role information in custom attrib box, using following format
shell:*
for e.g (if context name is Admin, domain is default-domain and you want to assign role "Admin" to this user )
shell:Admin*Admin default-domain
Hope it helps
Syed -
Inventory collection fails for ACE module (RME 4.3.1)
I am trying to collect the inventory and ultimately the configurations for my ace modules. When i try to do an inventory collection I get the error
Device sensed, but collection failed
Anybody have any ideas?
ChrisPost your IC_Server.log.
Please support CSC Helps Haiti
https://supportforums.cisco.com/docs/DOC-8895
https://supportforums.cisco.com -
ACE MODULE IN BRIDGE MODE NOT LOADBALANCING
Hi,
I setup an ace module in bridge mode as follows:
mfsc(vla80) > (vla80)outside fwsm, fwsm inside(vla40) > (vla40)ace-clientside, aceserverside(vla41)
and the servers have the fwsm svi(vla40) as their gateway. But, the ace is not loadbalancing.
The config script is attached. Is their anything I am missing?
AttachCheck my troubleshooting guide on this forum.
There are few things to do to narrow down the issue.
Gilles. -
Certificates vanished - ACE Module. Strange!
ACE modules are configured in Active/Standby context mode on two distinct Cat6500's. The feature license is 10,000 SSL tps, 8Gbps throughput.
We ran the application performance tests with 1000 users with https transactions and I noticed that the all the root certificates under the chaingroup disappeared. Only the website certificate remained. When I accessed the website, it gave 'error with the security certificate' i.e. the root was not identifiable due to missing certificates. Eventually, the CPU went 100% on Cat6500 and the ACE module was shutdown by the chassis. It got reenabled automatically in 5 minutes.
I re-added the root certs, removed/added the service policy and after sometime I noticed the root certs disappeared again. STRANGE !
show version output is
Cisco Application Control Software (ACSW)
TAC support: http://www.cisco.com/tac
Copyright (c) 2002-2006, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained herein are owned by
other third parties and are used and distributed under license.
Some parts of this software are covered under the GNU Public
License. A copy of the license is available at
http://www.gnu.org/licenses/gpl.html.
Software
loader: Version 12.2[121]
system: Version 3.0(0)A1(6.3a) [build 3.0(0)A1(6.3a) adbuild_02:16:25-2008/02/02_/auto/adbu-rel3/ws/rel_3_0_0_a1_6.3-thr
ottle/REL_3_0_0_A]
system image file: [LCP] disk0:c6ace-t1k9-mz.3.0.0_A1_6_3a.bin
installed license: ACE-08G-LIC ACE-VIRT-020 ACE-SSL-10K-K9
Hardware
Cisco ACE (slot: 2)
cpu info:
number of cpu(s): 2
cpu type: SiByte
cpu: 0, model: SiByte SB1 V0.2, speed: 700 MHz
cpu: 1, model: SiByte SB1 V0.2, speed: 700 MHz
memory info:
total: 957640 kB, free: 347924 kB
shared: 0 kB, buffers: 1588 kB, cached 0 kB
cf info:
filesystem: /dev/cf
total: 1014624 kB, used: 360960 kB, available: 653664 kB
last boot reason: NP 0 Failed : NP ME Hung
configuration register: 0x1
Could you please advise whether there is any bug in the above software version i.e. it removes the root certs due to heavy transaction load.
Thanks.I wanted to look for more details regarding this bug id. But I got the below message in Bug Toolkit. Please advise...
CSCsl96203 Bug Details
Information contained within bug ID CSCsl96203 is only available to Cisco employees. It is our policy to make all externally-facing bugs available in Bug Toolkit so the system administrators have been automatically alerted to the problem. By choosing to save this bug, you may be notified when the decision to make this bug available to you has been made. Note: Some product enhancement requests and documentation error bugs may not be available in Bug Toolkit. -
How can I configure ssh management access to the ACE module configured in bridged mode.
do not mix "domain" name and user "domain".
The domain name is something like cisco.com or yourcompany.net ...
But the user domain is what objects is a user allowed to modify/configure/access inside ACE.
I don't think you need to specify a domain-name to generate the key.
Here is what I did :
switch/Admin(config)# ssh key rsa 768
generating rsa key(768 bits).....
generated rsa key
switch/Admin(config)#
gdufour-cat6k1#ssh -l admin 10.86.213.40
Password:
Cisco Application Control Software (ACSW)
TAC support: http://www.cisco.com/tac
Copyright (c) 2002-2008, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained herein are owned by
other third parties and are used and distributed under license.
Some parts of this software are covered under the GNU Public
License. A copy of the license is available at
http://www.gnu.org/licenses/gpl.html.
User 'www' is disabled.Please change the password to enable the user.
switch/Admin#
Just make sure you allow SSH traffic with your management policy.
Gilles.
Maybe you are looking for
-
Dear All I am using Java mapping to change the filename dynamically. I am getting follwoing error in my receiver file communication channel. Message processing failed. Cause: com.sap.engine.interfaces.messaging.api.exception.MessagingException: com.s
-
Never used microphone input before, sound recorder window okay, no sound output.
Sound from sound recorder input goes nowhere, a sound window is supposed to open, it does not. There is some software missing in my pavilion g7 laptop. Media player sound is fine, internet sound is fine, only sound missing is from the microphone inp
-
OS 9 No Finder On Dual Boot with OS 10 FYI
Going down the long rabbit hole again. Time Slipping Away, Away. Love/Hate Computers/Software I recently tried to back up an older Power Computer running OS 9 only with my little used Dual Boot G4 which I have done for years. This time when I tried b
-
i have an i book g3 (500 mhz) running os 10.3.9. i bought this in 2001. the firewire has never worked. is there an update i can upload to get the firewire to work. mp
-
I use .Mac for mail on my phone. Is there anyway to reply to a message without including the original message in the reply? On my computers I don't have that option selected but I can't find anywhere on the phone to select or deselect that option. Jo