Hi experts,
Can we manage the life cycle of an Adapter, i mean are there administrative interfaces for Adapter-Framework-compliant adapter?
Plz help.
Regards,
Sushama

Hi Jose
> Currently we have interfaces with connection problems that causes the number of threads of the adapters is at maximum
The problem is not clear in your message. be clear in following things.
1. In what kind of adapters you have this problem?
2.how frequent is this connection problem?
3.Try analyzing why this problem is coming.
    there can be many reasons for this connectivity loss issue!
               1. Data transfer over thirdparty network.
               2. Prioritize of the data packets in the third party network (if in the 3rd party network prioritize is not done on it, by default our messages/threads will be assigned to lowest priority - so when data load is high in the network lowest priority messages gets canceled.) - this is one of major cause of data loss issue when we deal with 3rd party network.
4. If you are facing this connectivity issue File adapter please configure below properties in the adapter and do the test again.
      -> Set Connection mode -->per file transfer
      --> in advanced mode set "ftp.timeout" with value around 300ms.
     above two will ensure that the connection thread is released after each processing. else the thread wont be released.
PS: Connection is getting terminated because earlier messages are not releasing the threads after the message processing.
please give us more input what is the scenario/adapter used, what connection error u r getting what network is it connecting to (same network or 3ed party network).
Regards,
Senthilprakash

Similar Messages

  • Creating LabVIEW Executable for sub-20 Multi Interface USB Adapter

    Hi
    I'm using Sub-20 Multi Interface USB Adapter (www.xdimax.com) for GPIO and SPI. The code is based on .NET constructor Node. I can access the device and perform all the tasks but I'm unable to generate executable.
    The application comes up with this error (on any machine including the development machine)
    "This VI is not executable. The Full development version of LabVIEW is required to fix errors"
    I'm using labVIEW 8.2 and .NET Framework 4 is also installed.
    Thanks

    Hi AA76,
    That is good to know, at least we know the cause of the error.  The KB - How LabVIEW Locates .NET Assemblies shows the LabVIEW search directories.  I suspect what is probably happening in this case is the relative path.  If the system is looking for the same relative path this is probably different. You say that even on the development machine the .exe does not load the library.  Is this when you have just created the .exe or after running the installer?  If it is after running the installer what about before you build the installer?
    Finally where is the assembly located?
    Regards,
    James
    James Mc
    ========
    CLA and cRIO Fanatic
    wiresmithtech.com/blog

  • Adaptation of LIFA (LabVIEW Interface For Arduino) to other Arduino compatible boards

    Hello evryone,
     I am trying to use a ''Sakura board", which is an Arduino compatible board, having similar programming as Arduino. This board is manufactured by Renesas; more specifications on it can be found on the following link: http://sakuraboard.net/gr-sakura_en.html
    What I would like to know, is if the firmware used for LIFA to interface Arduino with labview, or the ChipKit firmaware, can be used to this kind of Arduino compatible boards.
    My aim, is to use the Sakura Board for acquiring signals from various pins(Be it digital or analog), and setting other pins (Digital) parralelly, using labVIEW, as this is done using LIFA, or LabVIEW interface for ChiKit!!
    Thanks in advance for your support.

    I haven't had any experience with the Sakura board, so can only go on the information on the website.
    I've used the Arduino LabVIEW interface previously, and it basically uses serial communications between the PC and the Arduino. This serial interface is provided by the on-board USB-serial converter (an ATMega8u2 running custom firmware).
    From what I can tell about the Sakura, it appears as a storage device when plugging into a PC, and doesn't seem to have a USB to serial converter. If this is the case, then the LIFA toolkit won't work. That said, my understanding of the Sakura board may be incorrect (for example I'm unsure what operation modes the slide switch changes between). If you can confirm it has a USB-serial port then LIFA may work. I guess the key thing is that the serial port is required.
    You may be able to use a software serial port (http://arduino.cc/en/Reference/SoftwareSerial) on the Sakura to communicate with a PC, though that would require a PC with a serial port, or an external USB-serial converter. This approach would also require you to modify the LIFA arduino code (located in vi.lib\LabVIEW Interface for Arduino\Firmware\LIFA_Base) to reference the software serial port. It's probably a long shot that this will work, as the software serial library has been written for AVR chips, making use of their specific internal timers.

  • User interface for updating/adding attributes in OID

    Hello,
    I have not done the develop work in OAS10g (web, oid, +) though I have years experiences as DBA in OAS and Oracle database servers.
    I need to develop a user interface for users to add or update the user's attributes such as sn, manager etc.
    The IDM system is working in prod: OAS 10g r2, installed (upgraded to) with infrastructure and oid 10.1.4.3.
    OID: user attributes have been loaded with: CN, UID, mail and etc.
    The requirement
    User interface: an app based Ohttp web 10g
    I'd like the interface works like:
    The user accessing the web interface, is prompted with UID and mail. if the user correctly fills the fields, then will be prompted with the attributes which user can add or update.
    Because I have Not done any development in OAS (web, oid), I need know what skills I need to aquire. ANd how should I proceed?
    I may know the skills would be Ohttp development and OID API (LDAP), but I need these be specific as much as possible.
    Can any point the direction with examples and docs?
    TIA
    GA

    ajaybabu007 wrote:
    For managing the user related activities (create,update,lock,unlock,delete and so on) through an Web UI interface can be administrated with the Oracle Identity Management Self Service Console (http://infra_host_name:7777/oiddas) which is an inbuild component of OID/OSSO. Please provide orcladmin/<password> credentials for accessing this Web UI.
    ---ABP thanks.
    1) the app for user to add/update the attributes. we cannot give orcladmin to them
    2) though the users as their own can access the oiddas, there are only limit of user info could be updated, which cannot serve the attributes we customized and loaded in OID.

  • What is the interface for MDD connected to monitor?

    I got an used MDD 1 GHz for child, which does come with any cord or accessories. The most surprise to me is its port for connecting itself to a monitor. I cannot find an interface for connecting it to the cord of the monitor. What is the part number or where can I find the interface?
    I would appreciate any help. Thank you very much.
    Robert

    It has 3 possible connectors for a Monitor...
    ADC Apple Display Connector...
    DVI...
    VGA...
    ADC to DVI adapter...
    http://www.eworldsale.com/belkin-adc30m-to-dvi24f-cube-adapter855630844.html

  • Dynamic destinations for adaptive web service in webdynpro for java

    Hi,
    Please advice me on how to create dynamic destination for adaptive web service model in webdynpro for java.
    Regards,
    Patana

    Hi,
    If this is the case, then use the HTTP destination for this.
    What you need to do is:
    1. Create one HTTP destination in visual administrator at services-> Destinations. Provide HTTP url of the your web service and the security options.
    2. Specify this HTTP destination in the code before executing web service model.
    Write following code for that:
    wdContext.current<node name>Element().modelobject()._setHTTPDestination(<Specify HTTP destination name>);
    Then execute your web service model.
    Now, whenever you want to change the server on which your web service is running, make change in the HTTP Destination in visual administrator.
    Refer this link,
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/b2bc0932-0d01-0010-6d8e-cff1b2f22bc7
    Regards,
    Sunaina Reddy T

  • How do I set up the port interface for the WAN side of my RVS4000 to 100T Full Duplex?

    How do I set up the port interface for the WAN side of my RVS4000? The ISP says I need to set it to 100T Full Duplex, but where would I do that? In the Router's administration GUI I can't find any options to make such settings for the WAN side.

    The setup of the folders in Finder is entirely up to you. Whatever suits your needs is what you should do. Lightroom will be fine no matter how you set it up.
    So I'm not really sure what your question is.

  • WEB Interface for Visual Admin

    Hi,
    I'm told there is a web interface for the visial admin tool which can be launched from the examples section of the j2ee home page.
    In order to do this you must first deploy the tool.
    I've search the net and marketplace for the tool to download and am unable to find it.
    Has anyone else come across this before??
    Thanks
    Jim
    Message was edited by: Jim OShea

    Hi Jim,
    Are you looking for the Netweaver Administrator?
    Links:
    http://service.sap.com/nwa ( you will need a SAP Service Marketplace user ID for this)
    Introducing SAP NetWeaver Administrator -NWA
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/fc03a2a2-0a01-0010-b497-87518550e132
    Blog : SAP Developer Network Blog: XI: NetWeaver Administrator - first look - Logs & Traces (by Michal Krawczyk)
    /people/michal.krawczyk2/blog/2005/05/27/xi-netweaver-administrator--first-look--logs-traces
    Cheers
    Manish

  • Ruby interface for 2.5

    Is there some Ruby interface for DBXML 2.5? I'm using http://raa.ruby-lang.org/project/bdb/ but it does not work with 2.5.16

    Wow - I'm really sorry to hear that. My knowledge of Ruby is non-existent, but if you wanted to take a look at adapting the existing Ruby bindings for DB XML 2.5 I'll give you any help I can. You can email me on first dot last at the obvious domain.
    John

  • I am having trouble sending an audio signal from my computer (mac pro early 2009) to my TV.  Is there some interface or adapter that allows /enables the audio input from my computer to be sent to the TV (R,L signal?) any suggestions

    I am having trouble sending an audio signal from my computer (mac pro early 2009) to my TV.  Is there some interface or adapter that allows /enables the audio input from my computer to be sent to the TV (R,L signal?) any suggestions

    just  the audio, eh?. If you were using DVI or DisplayPort that might be different, but for audio alone, it shouldn't be that hard.  Just grab a 3.5 mm stereo plug to 2 rca cables adapter. Plug the smaller end into the back of your Mac Pro (or the Front), where you see either the headphone or speaker icon). Alt-click on the speaker icon at the top of your screen to show all audio inputs and outputs. Make sure it's set to Line Out.  Plug the red and white end into the audio in jacks on the back of your tv and set it to the correct input. I don't know if your tv will allow just the audio to play. Usually one has to connect up something else, but hopefully I'm wrong.  If you were using DVI, or DisplayPort, you'd need an active DVI--HDMI adapter or a DisplayPort to HDMI adapter, but
    I don't know for sure
    J  B  

  • Interface and adapter??

    could anyone tell me how to choose between using an interface and adapter for an event handler??

    > could anyone tell me how to choose between using an
    interface and adapter for an event handler??
    Example from the KeyAdapter API:
    "Extend this class to create a KeyEvent listener and override the methods for the events of interest. (If you implement the KeyListener interface, you have to define all of the methods in it. This abstract class defines null methods for them all, so you can only have to define methods for events you care about.) "
    It's an extremely important skill to learn to read the API and become familiar with the tools you will use to program Java. Java has an extensive set of documentation that you can even download for your convenience. These "javadocs" are indexed and categorized so you can quickly look up any class or method. Take the time to consult this resource whenever you have a question - you'll find they typically contain very detailed descriptions and possibly some code examples.
    Java� API Specifications
    Java� 1.5 JDK Javadocs

  • Administrative Groups- for MPLS TE

    Do the Cisco 7600's have an equivalent to Juniper (and Riverstone's) Administrative-Groups feature? I would like to do MPLS-Traffic Engineering based on the Administrative groups? I have tried searching this feature, but haven't found anything. There might be a different name for this feature which I might not be aware of. I would appreciate if somebody could help me with this.

    Thanks Jon.
    I am not sure if Affinity bits is the same feature as administrative groups(color)
    Below is the description of Administrative groups that Juniper implements:
    Administrative groups, also known as link coloring or resource class, are manually assigned attributes that describe the "color" of links, such that links with the same color conceptually belong to the same class. You can use administrative groups to implement a variety of policy-based LSP setups.
    Administrative groups are meaningful only when constrained-path LSP computation
    is enabled.
    Administrative groups require three levels of configuration. First, configure a table of group names at the [edit protocols mpls] hierarchy level:
    [edit protocols mpls]
    admin-groups {
    group-name group-value ;
    You can assign up to 32 names and values (in the range 0 through 31), which define a series of names and their corresponding values. The administrative names and values must be identical across all routers within a single domain.
    To configure administrative groups, follow these steps:
    Define multiple levels of service quality:
    [edit]
    protocols {
    mpls {
    admin-groups {
    best-effort 1;
    copper 2;
    silver 3;
    gold 4;
    violet 5;
    Define administrative groups for an interface. These groups identify the administrative groups to which an interface belongs. You can assign multiple groups to an interface.
    [edit]
    protocols {
    mpls {
    interface interface name {
    admin-group [ group-name group-name...];
    If you do not include the admin-group statement, an interface does not belong to any group.
    IGPs use the group information to build link-state packets, which are then flooded throughout the network, providing information to all nodes in the network. At any router, the IGP topology, as well as administrative groups of all the links, are available.
    Changing the interface's administrative group affects only new LSPs. Existing LSPs on the interface are not preempted or recomputed to keep the network stable. If LSPs need to be removed because of a group change, issue the clear rsvp session command.
    Configure an administrative group constraint for each LSP or for each primary or secondary LSP path, at the [edit protocols mpls label-switched-path lsp-path-name ] or [edit protocols mpls label-switched-path lsp-path-name (primary | secondary)] hierarchy level:

  • Unlocking administrator password for hp pavilion dc7

    Need help unlocking administrator password for hp pavilion the disabled key code is 51124125 please can anyone help me
    This question was solved.
    View Solution.

    Steps to be followed:
    1. Use the unlock code posted above to enter the BIOS
    2. Disable all passwords that are enabled
    3. If asked for current password - type the unlock code
    4. For new password, just press ENTER key
    5. Repeat the same for verify password column.
    6. Then leave the BIOS by saving & exit option to save the changes.
    Troubleshooting:
    Incase if the Password doesn’t work please try a Hard Reset as follows.
    1. Shut down the notebook
    2. Unplug the AC Adapter and then remove the battery
    3. Hold down the Power button for 30 seconds
    4. Plug in the Power/AC Adapter (Leave the battery out for the moment) & Start the Notebook
    5. If you now see a password box, Please type the same Password I shared before and press enter
    Hope this helps, for any further queries reply to the post and feel free to join us again
    **Click the KUDOS star on left to say Thanks**
    Make it easier for other people to find solutions by marking a Reply 'Accept as Solution' if it solves your problem.
    Thank You,
    K N R K
    Although I am an HP employee, I am speaking for myself and not for HP

  • I forgot the administrator password for my mac and cant set a new one without it how can i set a new one

    i forgot the administrator password for my mac and cant set a new one without it how can i set a new one

    Reset Password 10.7, 10.8...
    http://reviews.cnet.com/8301-13727_7-20087723-263/how-to-run-the-password-reset- utility-in-os-x-10.7-lion/

  • Problem to deploy to a WebService interface for ADF Business Components to Weblogic Server

    Hi,
      I'm trying to deploy a custom application ,in which i have exposed ADF Business Components through a WebService interface, to a standalone weblogic server.
    Application Module is configured with a Service Interface for ordinary ViewObjects.
    Now I want to create a EAR file of this application to deploy it on the weblogic server.
    But I got an error while deploying it.The error i am getting is shown below.
    ERROR: No Java EE modules detected in EAR archive. Deployment aborted. == (oracle.jdevimpl.deploy.ear.WeblogicAssembler)
    I have followed the steps mention in the below link :
    http://technology.amis.nl/2010/12/29/quickly-creating-reploying-and-testing-a-webservice-interface-for-adf-business-components/
    I'm using Jdeveloper 11.1.2.4 on windows.
    Please suggest what i could be doing wrong.
    Regards,
    Himanshu

    Does the deployment profile include Java EE modules?
    Refer
    Java EE Developer: ERROR: No j2ee modules detected in EAR archive. Deployment aborted. == (oracle.jdeveloper.deploy.Veto…

Maybe you are looking for

  • Firefox process starts but window doesn't open.

    All the suddenly when I start Firefox 11 the window doesn't appear but the process will start in task manager. Yesterday morning everything worked well, but when I came home at evening Microsoft Security Essentials wasn't starting it's protection. I

  • Message id in auto-reply

    Dear All, Can we remove the message-id from the auto-reply? in an auto-reply the message bounces back to the user including in the body part the following: Message-id: <[email protected]> Date: Thu, 31 Jul 2008 21:36:08 +0300 From: [email protected]

  • IBook G4 Won't Start -- iSight magnet at fault?

    Someone in the family put the iSight magnet down near the touchpad and now the computer won't start up. I tried restarting with the install disk but all I get is the start up sound and then a blank gray screen. Any advice? iMac G4   Mac OS X (10.4.1)

  • Multiple EOIO queues

    hi I have about 100 file to JDBC interfaces and I need to have EOIO sequencing on the sender file adapter.. because 2nd file should not be processed if the 1st file goes in error.  Will I need 100 seperate Queue names in the 100 sender channels that

  • Business Role Assignment to User by Organizational Model

    We have created the organizational model in our system where we have the levels that are tied to a specific business role. We have been manually assigning all of our users to these organizational model levels in order to have the business role assign