Audigy 4 Pro Hub Analog inputs problem

&Analog inputs in Audigy 4 Pro external hub seem to be unsupported in Windows 7. Am I wrong?
I installed latest drivers, set mixer to monitor sound from line in, also tryed win ASIO, but I am unable to get any sound from Line in/Mic in.
Please help me clarify this issue, I?ve been trying to find an answer through different forums for hours! Thanks

Issue solved... line in /Mic is now working. Audigy 4 pro analog input is supported using latest windows 7 drivers.

Similar Messages

  • LM3S8962 Analog Input problem

    hi everyone,
    i am using a custom made electronic board using LM3S8962. In labview 2012 embedded after creating the new project and selecting the processor type, I add new elemental io, choose the analog input and get an error.
    With digital input, I have error too:
    "An internal software error has occurred. Contact National Instruments technical support at ni.com/support. Error details:
    1003 : Open VI Reference in EIONode_CommonScripter.vi:1->EIONodeCodeGen.vi:3->EIONode.xnode:EIONode_GenerateCode.vi:1->EIONode.xnode:EIONode_GenerateCode.vi.ProxyCaller<APPEND>
    VI Path: <b>C:\National Instruments\LabVIEW 2012\Targets\Keil\Embedded\RealView\EK-LM3S8962\eio\EK-LM3S8962_EIOScriptNode_0.vi</b>"
    What does this mean???

    Error 1003 means a VI being called is not executable or one of its subVIs is unable to be found.  Try checking the file path in the error message and seeing if you can find the VIs it lists. You may have had some kind of installation issue and a dependent VI for LabVIEW Embedded may not have been installed in the correct place.  You could try a reinstall or a force reinstall to make sure the files are all in the correct place.  
    Regards,
    Eric L.
    Applications Engineer
    National Instruments

  • Analog inputs no longer working on Audigy 2 ZS Platinum Pro's external dr

    I have an Audigy 2 ZS Platinum Pro. After two years of use without problems, the analog inputs on the external dri've have stopped working. I get no signal from them, not even noise. All 3 inputs are silent, Line in / Mic and Line 2 in the front, and Line 3 in the back. Otherwise the dri've appears to function normally - I get output from the headphone jack, and the volume control knob works. I have not tested digital inputs or outputs, as I currently have no digital devices to connect to them.
    I had made no major changes to my computer - software or hardware - when the problems began. I recently added a new SATA hard dri've, but the Audigy dri've did work after that.
    I've taken steps suggested in another thread on this forum and uninstalled all Creative software and drivers, used the latest driver package's uninstall program as well as Driver Cleaner, and finally manually deleted everything related to Creative and Audigy from the system registry (and rebooted quite a few times in between). I then installed the original drivers from the CD that came with the sound card (a setup that has worked before), but still the problem persists.
    Any ideas on where to even begin looking for a solution? I find it hard to believe that it's a hardware problem, since three inputs suddenly went silent at the same time, and no other connections were affected. Yet I've done as clean a reinstall as possible, and that hasn't solved the problem.
    My current computer configuration:
    OS: Windows XP Pro (SP2 and all latest updates)
    CPU: Athlon XP 500+
    RAM: 2x 52 MB
    Motherboard: Abit AN7 (integrated sound chip disabled)
    Video card: Sapphire Radeon 9800 Pro
    Network card: D-Link DFE-530TX
    Hard dri've : Seagate ST320026A, 20 GB IDE
    Hard dri've 2: Maxtor 6L080J4, 80 GB IDE
    Hard dri've 3: Seagate ST330083, 300 GB SATA-II

    I don't have a Platinum Pro or the dri've, but a general hardware troubleshooting step I would take would be to remove the soundcard and either move it to another slot or re-seat it. Also, I'd disconnnect and reconnect all cables to and from the card and the dri've. If I had another machine I could try the card or dri've in, I'd do that. If I could borrow another dri've or even another card, I'd test those too. (Swapping parts is often the simplest diagnostic.) Yeah, maybe it's not a hardware problem, but I'd take these steps just to rule out some possibilities.
    Edit: And if you can remove or disconnect the SATA dri've and restore the system to the condition before you installed it, that's another good test.Message Edited by Katman on 2-8-2005 2:56 AM

  • Mac Pro no analog audio input

    The analog audio input on my Mac Pro has stopped working.  Audio output still OK; USB audio input works fine but nothing from analog audio input.
    I know it's getting a signal as I can send the mixer output to a Zoom H4n and it records fine, but I need it to go directly into the computer for tutorial voiceovers.  I've tried recording in Quicktime Player, Soundtrack Pro, Camtasia and Screenflow.
    I get no volume indication in the System Preferences>Sound panel.
    I opened Apple Midi Setup>analog input and I can adjust volume on the two channels but "Master" is stuck at zero.  Could this be the problem?

    See if a smc reset shakes it loose.
    Just to be clear here.  Are you inputting into a program and expect to hear it as well? If so, then unless the program itself has some kind of audio playthru to the speakers you need a app like LineIn to handle that function.

  • Problem with the analog input acquisition in labview fpga 8.5.1 and CRIO

     Hello all,
       I am using NI CRIO 9104 RT controller with 9014 FPGA chassis.I am using an Analog input module 9205.My problem is with the acquisition.I am using a
    function generator which generates some sine wave of -1 to 1 ,5hz to125khz sine signal and i have connected to 9205 in rse mode.In FPGA vi i had placed the I/O node and placed an indicator(data type FXP).If i connect the i/o node to a chart or graph,i am not able to see the output.?How this problem can bbe solved
    Next i had placed a FIFO in DMA transfer mode of depth 1023 which will accept the U32 datatype,so i did some manipulation as mentioned in a tutorial.
    Now in RT VI i am reading the same data from the buffer in U32 and doing the reverse manipulation i am able to view the data.Now the problem is ..if i am
    increasing the frequency of the input signal,the data is completly lost ?How can i overcome this problem...
    thanks in advance,
    srikrishna.J
    Analysis Engineer,
    Neurofocus

    Difficult to see where is the problem ....
    Be sure you are doing a good RT system by grabing reference design examples
    Don't forget to specify the DMA FIFO size in the RT code
    Doesn't matter the size of the DMA size under the FPGA project explorer.
    Upload your code, You will get answers...
    Mathieu

  • 7831R Analog Input Noise Problems

    Hi,
    I am running a data logging application which samples the analog inputs of my 7831R FPGA card with a sample rate of 10KHz. I am interested in how noisy the PXI system itself is, so I shorten AI0+ and AI0- together, hook both of them up to A0GND through a 10K resistor (all done in the SCB-68 breakout box which is connected to the FPGA card through a SH68-C68-S cable) and log data from the analog input.
    The data log shows about 12 counts of noise in the system. That's about 3.5 bit. Is there any way I can reduce the noise?
    Thanks,
    Chris

    Hi Pete,
    You are right in saying that the 7831R boards should acquire data much faster than 10KHz. Infact you can take a look at the actual specs from the data sheet http://sine.ni.com/nips/cds/view/p/lang/en/nid/14757 as well as the product manual. However, I am concerned that you may be measuring the rate of acquisition on the RT VI (or any host vi) you are running as opposed measuring it in the FPGA VI.
    Your time critical loop may be running at 228 ticks of the 40 MHz clock but the data is buffered (at that rate) and has to be then transferred to the communication loop which then sends the data to the host vi (which may be your RT vi). Hence, the rate at which host VI receives the data will be much slower than the FPGA VI is acquiring data.
    Hope this helps!
    Prashanth

  • Joe Meek Twin Q Pre-Amp and Elite Pro SPDIF/Digital input probs

    Hi. I'm wondering if anyone can help. I've just purchased a Joe Meek Twin Q Pre-Amp and I specifically bought it for a new Rode mic I've just got and it needed phantom power. I also paid a little extra for the digital 'outs', thinking I could take an optic or SPDIF out into the Elite Pro breakout box. The problem is, is that digital is not recognised at all - in Audio Codes it states it's an invalid signal. However, SPDIF is recognised saying it's a stereo signal at 48,000hz, but is only being 'heard' in my right channel.
    I have tried the line out into Line In 3, and there's no problem there. Joe Meek representative said it should be working as long as the bit match is the same in both units, which as far as I know is. Am I missing something here? I'm awaiting Creative to get back as it seems to me to be a breakout-box hardware problem, but I could be missing something?
    Does anyone have any experience and/or advice/info?
    Thanks in advance

    Well, since you're not getting response, let me see what I can do.
    I think you're saying the optical connection isn't working, but the coax (SPDIF) one is working, and then you're only getting the mic signal on one channel. The second part is easy to explain, but I never remember the solution suggestions. TOSLink/SPDIF, essentially, are stereo signals, and your preamp is simply putting its channel 1 signal on one side and its channel 2 signal on the other. If you had a second mic connected to the other connector, you'd have one mic on the left channel and the other on the right channel. Basically, you need to treat it as a mono signal and then either pan it into the stereo field, or just duplicate (convert) it to stereo. I'm sure there are ways, but someone else needs to join in with some experience. I'm not sure, but it seems to me if, say, you've put the mic in the channel 1 connector, you could take the channel 1 (analog) output and patch it into the channel 2 line input, and your digital outputs would probably get you the mic signal on both sides.
    On both devices, the TOSLink/SPDIF signals are, to the best of my understanding, basically the same thing in two forms. If one is working, than the other should be working too. That suggests to me either hardware brokenness in the preamp's optical out, or the Elite Pro's optical in. or a problem with the optical cable. CL's optical outs can be checked to see if they are putting out red light: if they aren't, there's a problem. That probably applies to the preamp, in this case. You can simply connect the Elite Pro's optical output to its optical input and record something from the digital input device. If that works, the cable and the digital input are probably OK, and it most likely the preamp's digital output is broken (although it could be a strange compatibility issue). If it fails, then it's most likely either a bad cable, or the Elite Pro's optical input is broken. Trying another cable, or some other piece of gear you have that outputs optical, ought to sort out which it is.
    -Dave
    [email protected]

  • Synchroniz​ing two counter frequency inputs with multiple analog inputs

    Hello all,
    I'm fairly new to LabVIEW and I'm trying to collec​t data from multiple sources with synchronized tim​ing on the acquisition but I'm having trouble figu​ring it out. My problem is that I've got two count​er frequency inputs, one optical tachometer readin​g one pulse per revolution, and a max machinery fl​ow meter with a k factor of 12000. I can't seem to​ figure out how to sync the timing with my multiple analog inputs. I've be​en attempting to get the tachometer  to sync with ​the analog inputs first by following the example l​inked here. (https://decibel.ni.com/content/docs/DOC-10785) So far each time I run it I either get a timeout e​rror on the DAQmx read or a "Multiple sample clock​ pulses were detected" error (see attached image).  It seems if I slow the sampling rate way down to ​say 10 hz and ensure that the tachometer signal is​ over 800-1000 RPM (13-17 Hz) before starting the VI then the program will run without errors until ​the RPM drops below that threshold then the "Multi​ple sample clock pulses" error occurs.  The code is attached below.
    Does anyone know of a more effective way of syncin​g counter frequency inputs with analog inputs?  I'd like to have a VI that can show 0 RPM (and ev​entually 0 flow as well, but I think I need to fig​ure out the timing of one counter before I add ano​ther as it seems I can't have two counters in the ​same task). Any help on this would be greatly appr​eciated.
    LabVIEW version 13.0
    cDAQ-9178 Chassis with NI 9401 for the two counter inputs and NI 9205 for the analog inputs.
    Thanks!
    Richard
    Solved!
    Go to Solution.
    Attachments:
    SimpleDAQ.vi ‏44 KB
    LV_Error.JPG ‏31 KB

    Maybe third times the charm? 
    So I've finally got a good handle on why the VI is having problems at low RPM though I'm somewhat embarassed how long it took me to do that
    Because I have the counter time synced to my Analog input task if it doesn't see at least two pulses between the two clock pulses set by the analog input task I get the -201314 "Multiple sample clock pulses" error. This seems fine at first as it just sets a minimum RPM that I can measure and it's well below the area I'm interested in so no problems there.  I tried a simple error handler that would clear the error when it happend assuming the loop would keep iterating until the RPM went above that minimum at which point I would get a signal again. This is not the case, the read function just continues to spit out the -201314 error even after the RPM is back in the readable range. So then I tried adding two case structures so that when the error occured it would stop the task, clear the error, and then start the task again on the next loop iteration (Code Attached). This also doesn't work as the error shows up again on the stop task and then AGAIN on the start task on the next loop iteration. It seems this error is not actually being cleared and once it happens it stays with the task regardless of what the error cluster is carrying. 
    Anyone have any ideas?  The only solution I can think of is to just clear all tasks and recreate them each loop iteration until the RPM is readable again but that strikes me as a horribly clunky solution.
    Richard 
    Attachments:
    SimpleDAQ_1_Start Stop.vi ‏48 KB

  • The device PCI 6036E: Analog Input error:"the device is not responding to the base address",Output :No signal

    I am using PCI 6036E DAQ card, DAQ 6.9.2. , I have not connected to any external device.
    When I tested card(in Test Panel of MAX2.2,DAQ 6.9.2) an error appearing �the device is not responding to the base address� � then I pressed Yes, Then TestPanel window appearing�
    In analog Input Tag, there is an error �-10805�. This error also appearing when I run the standard analog input samples (use Delphi 6.0).
    I tested analog output functions in TestPanel, Delphi Examples, LabView 6.1. There are not error appearing but there is not output signal (using Oscilloscope to see).
    Output, Input digital functions are working correctly.
    Next I try to foll
    ow all the instruntions as recommended:
    -Changing TO another slots PCI
    -Reinstall Os WinXP,98SE�
    -Use another Computer�
    But all of the cases are still not working.(the above error still appeared, no output signal)

    Nvd,
    I'm sorry to hear about the problems that you are running into with your DAQCard. I can understand your frustration with the errors that you are seeing. You mention that you have tried to do some troubleshooting, I was wondering if you have tried all the troubleshooting techniques listed in this KnowledgeBase:
    http://digital.ni.com/public.nsf/websearch/DCFCDB240788F8D486256D6A00834D80?OpenDocument
    If you have tried all of those things, I would suggest one additional thing to try. I would suggest updating your NI-DAQ drivers to version 7.0. These drivers are the newest versions of our Data Acquisition Drivers, and can be downloaded from our website here:
    http://digital.ni.com/softlib.nsf/webcategories/85256410006C055586256BBB002C128D?OpenDocument&
    node=132060_US
    If you have tried all of the above troubleshooting options, please post a detailed description of what you have tried. This may help to clarify what is going wrong.
    Jed R.
    Applications Engineer
    National Instruments

  • PID Control - analog input, digital outputs

    Hello everyone,
    I am trying to use the PID toolkit to convert my existing feedback control system to one using PID or just PI whatever works best. Problem is that the tutorials out there discuss in detail about obtaining Analog inputs and using the PID output to control an analog output. Are there any tutorials that show how I can control my process variable which is an analog input by using the PID output to generate digital outputs?
    Basically, what I am doing is controlling the incline of my device with two digital outputs that control two solenoid valves. The angle is calculated from a calibration curve that plots distance sensor voltage with Angle. Any help would be immensely apprecitated. I want to try this out on my own before I post some vi's. Thanks!
    V
    I may not be perfect, but I'm all I got!

    That is exactly what I am doing currently. I have error bands specified around the target to make sure that it doesn't oscillate. But, under load conditions such as pulsed load conditions, the device goes out of bounds and the values trigger to correct for it. But, what I need is seemless or atleast seemless correction. Currently what I see is sudden adjustments to the incline. Please find attached what I am currently using. I am trying to get a more finer solution if at all possible.
    Note: Within 5% of the target = NO action
              Between 5% and 15% = Pulsed ACtion ( DO On for Pulse width time)
              Greater than 15% = continuous action until it reaches Pulse band
    I may not be perfect, but I'm all I got!
    Attachments:
    TDML_subElevationControl.vi ‏41 KB
    TDML_subPulsedValveFuntion.vi ‏16 KB

  • Different Sampling rates for different channels in Analog Input

    Hi,
    I would like to acquire data at different sampling rates on different channels say ACH 0, ACH 1 and so on. I have a PCI 6052E board and NI DAQ 6.9.2. Also is it possible to simultaneously perform Analog output on two different channels along with the Analog input? What will be the problems/consequences as far as the system resources are concerned. I am a beginner in this area and would greatly appreciate any help/pointers for my queries.
    Thanking you in advance
    Deepak

    Search the eaxamples that ship with LV.
    Theer is one called simultaneous input and output or something like that.
    It will get you started.
    re: multiple scan rates. This is acoomplished by sampling all channels at the highest rate and throw away the expttra samples you do not need.
    Ben
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction

  • How to use counter output pulses to trigger analog input?

    Hello all,
    I hope the kind people using this forum can help me, a lowly beginner LV programmer! I have been attempting to create a VI that produces a user defined number of TTL pulses, separated by every n seconds. Each TTL would be outputted to a stimulator, which in turn generates its own TTL. Using the stimulator-generated TTL, I would like to trigger finite analog data acquisition (e.g. for every TTL, trigger the collection of a data sweep that contains 4000 samples (collected at 4000 Hz), with 1000 samples collected pre-trigger. I would like to also be able to see each data sweep as it is triggered on a chart. As I understand things (lots of online/book/forum reading), I should be using the counter output to generate my TTL pulses, and syncing each counter produced TTL with analog input, as well as using a reference trigger. Also, the AI part should be started first, so that I don' t miss any counter outputs. If it matters, I also need to use one of the AI channels to acquire the TTL, so I can see my stimulator-induced responses to the stimulator in time.
    I am able to generate the TTL pulses from the counter output, but I am having a problem with the AI part. I am unsure how to sync the counter output with AI. Also, since I need to acquire pre-trigger samples, I would be needing to acquire samples continuously, but when I set 'continuous samples' on daqmx timing, the VI doesn't work (hence why's its set to 'finite samples').
     I hope someone out there can help, as I have been at this for what seems ages, with limited success. I am using a USB-6259 and LabView v8.2. Thanks!
    Attachments:
    RC001 v_1.vi ‏49 KB

    Hello,
    Due to the fact that analog tasks themselves are not retriggerable, a
    pulse train produced by a counter is always used as the sample clock
    for the analog input task in order to recreate a retriggerable effect
    for analog input. This can be done by creating a finite pulse train set
    to retriggerable using the DAQmx Trigger Property Node, or the pulse
    train could be continuous and just be gated by another signal. Neither
    of these methods can be properly applied in hardware to create a
    retriggerable reference trigger. You can however implement something
    similar in software by just stopping and restarting your reference
    triggered analog input task within a loop. There will be some delay
    between when the task is stopped and restarted, as these events require
    software intervention, but if there is enough time between when each
    trigger signal is generated, there should not be any noticeable delay
    or missed samples.
    I have attached an example of this!
    Mark B
    ===If this fixes your problem, mark as solution!===
    Attachments:
    RC001 v_1mod.vi ‏25 KB

  • Programming Analog Input Registers for MSeries NI-6221

    I am trying to understand the Preliminary M Series Register Map in order to correctly setup and acquire data from the Analog Input channels of my PCX-6221 card. I have been able to figure out the DIO locations and use them but I am having trouble understanding what I have to do to configure and acquire data using the Analog Input registers of the card. I need to program at this level for an RTX application using Microsoft Visual Studio Net 2003 and have had great success doing so with other NI Cards. I have tried looking at the examples provided by the MDDK but I haven't been able to create a environment that allows me to compile them with Chipobjects and it appears like alot of the work is hidden by the subroutines.
    I wonder if someone had a high level algorithum using the Register Map it would help out alot.
    Questions:
    How would I create a multiple channel Scan List and load it into the card setting gain etc...
    How would I configure the card to acquire continously at a specified freq (ex 1000 samples a sec)
    How would I start/stop acquisition
    I would guess getting the status of the FIFO and accessing the FIFO is a matter of reading the AI_STATUS_1 and AI_FIFO_DATA locations
    Would looking at the Register Programming Manual for the "E" Series help me or just get me more confused?
    Thanks in advance for any light you can shed on the subject.
    Floyd

    Hi Floyd-
    Let me address your questions individually:
    How would I create a multiple channel Scan List and load it into the card setting gain etc...
    A multi-channel scanlist can be created as shown in the method aiConfigureChannel() from ai.cpp in the M Series MHDDK \Examples folder.  Note that the other operations leading up that point (notably, aiClearConfigurationMemory() must be performed in the order shown in the various AI examples.  aiex3.cpp is the most useful starting point for investigation, in my opinion.
    How would I configure the card to acquire continously at a specified freq (ex 1000 samples a sec)
    aiex3.cpp shows how to setup the device and its DMA controller (aka the "MITE") for DMA operation.  In order to configure for continuous operation you set the "continous" flag in that example to kTrue.  The effect of that setting is to program the STC-II to generate either a finite or continuous AI sample clock.  This programming is performed in the function aiNumberOfSamples() from ai.cpp and has the effect of setting the appropriate bitfield for continuous operation in the AI_Mode_1 register. 
    Earlier in your post you asked if the STC Technical Reference Manual ( http://digital.ni.com/manuals.nsf/websearch/E929838D7D0EE50986256728007FEADF ) would be a good reference.  In fact, it's a great reference from the perspective of understanding the bitfield/register names and understanding the basics of how the timing hardware works (for example BC, UC and other sample counters are all functionally equivalent in the STC and STC-II).  From the perspective of actual register writes and reads, the functionality is different between E Series and M Series.  The biggest difference, as another forum user alluded, is that we map and write directly to the registers on M Series so Windowed_Mode reads and writes are no longer necessary.
    Another difference between STC and STC-II is that the STC-II uses NI TIO-style counter/timers.  For that reason, the NI 660x RLP manual ( http://digital.ni.com/manuals.nsf/websearch/4CE1C778F442B01386256C870060F9F3  ) would be a good reference for M Series counter/timer operations.
    How would I start/stop acquisition
    Assuming you don't need an external start trigger, you only need to write to the strobe bit AI_Command_2->AI_START1_Pulse.  This will create a single start trigger pulse internally.  The differences between AI_START1 and AI_START are described in the STC Technical Reference Manual.
    A finite acquisition would be stopped automatically by the AI timing engine based on the number of samples you program via the method shown in aiNumberOfSamples().  Continuous AI would be stopped by first stopping the DMA operation and then calling aiReset().
     I would guess getting the status of the FIFO and accessing the FIFO is a matter of reading the AI_STATUS_1 and AI_FIFO_DATA locations
    Yes, this would work but I would strongly suggest using DMA as shown in aiex3.cpp.  If you want to use "programmed I/O" to read the FIFO data directly, that method is shown in aiex2.cpp
     Would looking at the Register Programming Manual for the "E" Series help me or just get me more confused?
    In many cases it would be very helpful.  See my comments, above.
    I have inherited code that works on 65xx cards which I am pretty sure uses windowed mode that I am using in this 6221 driver. I have found that I can set the PLL registers to act as DIO and I can read the Discrete inputs just fine. Makes me curious, if Windowed mode is not used doesn't that mean the addresses are relative to the BAR1 address? Why then am I able to read the DIO?
    I'm not sure why this would work- it's possible that some legacy functionality is still working due to the way you access the hardware in your code.  For full functionality with M Series you must use mapped memory I/O to write and read from the device's registers.
    Also starting with Clock_and_FOUT according to the example I set it for Slow_Internal_Timebase. But when I read back that Address it is always zero. According to the register map it is a "write". Does that mean I can't read it's contents? Or do I seem to have a problem because I am trying to use windowed mode with this card.
    Yes, the "write" registers are write-only and the "read" registers are read-only.  The effect of data read from or written to "write" or "read" registers, respectively, is undefined.
    Hopefully this helps-
    Tom W
    National Instruments

  • NI-MyRIO Analog Inputs

    Greetings,
    I'm just getting the myRIO up and running, and I'm sort of disappointed that the +/- analog inputs are differential only. Is there any low level way to use these channels differently, or at least each as single-ended? Pseudo-differential, perhaps? I'm going to have to resort to using the line-level audio inputs to measure single ended inputs and make sure the input level is lower than whatever the max voltage is for that (1.7 volts or something).
    Any users out there care to comment?
    I know the other inputs are single ended, but only 0-5V. Bummer.
    Thanks in advance.
    TR
    ><><><><><><
    Tommy R.
    ><><><><><><

    I grounded the 0- and 1- inputs of the two differential channels and had no problem measuring  single ended voltages going into 0+ and 1+. I was just expecting to be able to configure the four inputs to be four single-ended inputs like I normally can do on all other NI DAQ analog hardware. The project I'm working on needs four measurments (all +/- voltages), so I was hoping the two +/- 10 channels were reconfigurable to four, like I'm used to. I'm just going to have to be creative and use the audio inputs as well.
    ><><><><><><
    Tommy R.
    ><><><><><><

  • Labview performance suffering with analog input

    Hello,
    I am using a PCI-6036E and a cDAQ-9172 with LabView 8.0. I have created a VI that systematically writes four different digital outputs, three to the PCI-6036E and one to the cDAQ-9172.
    Just recently I added a thermocouple to the mix, using an analog input on the PCI-6036E to monitor temperature. Since doing so, I have noticed that the entire VI runs extremely slowly.
    Before installing the thermocouple, the VI slowed down a bit if left to run continuously (for days at a time). Now, however, the VI slows down a great deal if left to run for more than a few minutes. It is so bad that the "Elapsed Time" display will not properly display the elapsed time.
    Because this application will be run for days, even weeks at a time without being stopped, this gradual decrease in performance is a huge problem. The application needs to run very accurately and precisely. I have attached my VI below. Is there any way to fix this issue? Any help is greatly appreciated, as I am new to LabView.
    Thanks,
    Nick

    I didn't look at the code (yet), but do you have a slow analog samplerate?
    Look here
    And here (a KB aticle)
    Ton
    Free Code Capture Tool! Version 2.1.3 with comments, web-upload, back-save and snippets!
    Nederlandse LabVIEW user groep www.lvug.nl
    My LabVIEW Ideas
    LabVIEW, programming like it should be!

Maybe you are looking for

  • Remote installation of Adobe AIR on Apple OS X 10.6.8

    Hello all, I'm attempting to remotely install Adobe AIR via SSH on an Apple OS X machine running 10.6.8 (64-bit) when no users are logged in locally. Let's say I remotely mount the latest dmg released for Adobe AIR using the hdiutil command on the de

  • Wrong Accounting entries in Import Procurement

    Hi SAP Experts, I m facing 2 issues of wrong accounting entries in Import procurement. 1) Vendor field is not showing while making PO in item Condition details for Additional duty condition type. 2) Secondly the accounting entries may be coming wrong

  • Xcelsius Engage 2008 installation error - office xp required

    I'm install a new machine, moving my applications from Vista to 7. On the new system i've already installed Office 2010.. I am trying to install Xcelsius Engage 2008 and recieve the following error msg's: 1. Office XP application: Excel, Word, Outloo

  • Error- PPDS Planning board -Heuristic 'Adjust and Reschedule Block Limits'

    Hi, I have created a sales order in ERP and overload (within tolerance) a block of a block planning enbaled resource in APO. The block is overloaded. Then I've run the "Heuristic 'Adjust and Reschedule Block Limits'" under Functions-->Heuristics. Now

  • Downloading table file

    Hi Friends, How to download fields, field type, datatype, length, check table, short text from a table to a text or excel file. Regards, Line