 Hello all,
   I am using NI CRIO 9104 RT controller with 9014 FPGA chassis.I am using an Analog input module 9205.My problem is with the acquisition.I am using a
function generator which generates some sine wave of -1 to 1 ,5hz to125khz sine signal and i have connected to 9205 in rse mode.In FPGA vi i had placed the I/O node and placed an indicator(data type FXP).If i connect the i/o node to a chart or graph,i am not able to see the output.?How this problem can bbe solved
Next i had placed a FIFO in DMA transfer mode of depth 1023 which will accept the U32 datatype,so i did some manipulation as mentioned in a tutorial.
Now in RT VI i am reading the same data from the buffer in U32 and doing the reverse manipulation i am able to view the data.Now the problem is ..if i am
increasing the frequency of the input signal,the data is completly lost ?How can i overcome this problem...
thanks in advance,
srikrishna.J
Analysis Engineer,
Neurofocus

Difficult to see where is the problem ....
Be sure you are doing a good RT system by grabing reference design examples
Don't forget to specify the DMA FIFO size in the RT code
Doesn't matter the size of the DMA size under the FPGA project explorer.
Upload your code, You will get answers...
Mathieu

Similar Messages

  • I have problem with the mic....sometimes others can hear me and other times not at all

    i have problem with the mic....sometimes others can hear me and other times not at all

    can anybody provide me with the solution

  • Upgrade to version 10.5.x, error - "There is a problem with the Windows Installer Package". I'm installing as Administrator, and have done an uninstall of the earlier version. Any ideas??

    Hi; Attempting to upgrade to version 10.5.x, but I keep on getting an error - "There is a problem with the Windows Installer Package". I'm installing as Administrator, and have done an uninstall of the earlier version. Any ideas??
    Needing to upgrade to allow connection of a 4S iPhone to the Laptop.
    Thanks!! - Tim.

    Repair your Apple Software Update.
    Go to START/ALL PROGRAMS/Apple Software Update. If it offers you a newer version of Apple Software Update, do it but Deselect any other software offered at the same time. Once done, try another iTunes install
    If you can't find ASU in all program, you can do it in CONTROL PANEL, ADD N REMOVE PROGRAMS.

  • After a successful home button repair, I've got a buzzing sound when I make or receive calls. No problem with the speaker as I can listen to online radio stations and my music.

    After a successful home button repair on my iPhone 4, I've got a buzzing sound when I make or receive calls. No problem with the speaker as I can listen to online radio stations and my music.

    I guess your definition of a "successful repair" is different from most people's.
    If you got it serviced by Apple, take it back to them.
    If you had it serviced by a 3rd party, Apple won't touch it. Take it back to whoeever fixed it for you.

  • X Fi - Problems with the Analog Jac

    Hi i recently upgraded to the X Fi XtremeGamer and my microphone is not working. the sound is working perfectly fine, amazing actually.
    I've reinstalled drivers, changed PCI slots, asked around for tips, nothing.
    Is it common to have a red light coming out of the analog slot in the sound card? That doesn't seem right.
    I've also checked all the window settings for my microphone, and still no luck.
    Wish i could just call some tech support, argh!
    Please help, thanks.

    hmm, i checked the /support on the CD. It didn't come with a telephone number, it just gave me a message saying it provides telephone service for the first 60 days. where can i find this #? I just purchased my product a couple days ago, and if i can't seem to fix it, i'm gonna have to send it back in =(

  • Probleme with the caller input in CUC 8.5

    Hi, guys,
    I have an issue on CUC 8.5, knowing that I'm working on CUCM 8.5 as well.
    I'm trying to configure the caller input for a user in a way that when someone call this user and reach voicemail, he will press 1 to reach the extension XXXX, in case of no answer from XXXX extension, the call will be forwarded to YYYY.
    I really appreciate your help, guys,
    thanks in advance.

    Configure a CH with transfer settings to XXXX, set that as caller input 1, attempt transfer to.
    On phone XXXX set the call forward options to YYYY.

  • Having a problem with the curser on MacBook Pro in Mavericks. Erratic activation and control.

    I have little or no control of the curser. It cuts in and out without any command or direction from the pad or trackpad.

    i meant the bar from where i can go to file , options, edit. it depends on the program am using for example for itune
    Follow these steps to burn a high-quality audio CD using iTunes:
    From the Edit menu (Windows) or the iTunes menu (Mac OS X), choose Preferences.
    i cannot find the edit menu in the top of my program

  • Problems with the canon xf plugin for fcp 7 Can't log and transfer mxf files.

    Hi 
    I can't log & transfer mxf files from a c300 camera in FCP 7 even though I installed the xf plugin.
    When I looked at canon's website this link comes up but it doesn't work.
    http://usa.canon.com/nw3s/CanonUSA/DownloadContents/English/0200206002EN.htm
    Any suggestions?
    Or other plugins that might work?
    Thanks,
    James

    Hello jameskendi,
    The most obvious reason we can tell as to why this may not work properly is the version of FCP you are using.  You mention using FCP 7, although the plugin is specifically for FCP X.  This is why you're having such difficulty.  If possible, we'd recommend using an updated computer and or software to process these files. 
    Did this answer your question? Please click the Accept as Solution button so that others may find the answer as well.

  • Synchroniz​ing two counter frequency inputs with multiple analog inputs

    Hello all,
    I'm fairly new to LabVIEW and I'm trying to collec​t data from multiple sources with synchronized tim​ing on the acquisition but I'm having trouble figu​ring it out. My problem is that I've got two count​er frequency inputs, one optical tachometer readin​g one pulse per revolution, and a max machinery fl​ow meter with a k factor of 12000. I can't seem to​ figure out how to sync the timing with my multiple analog inputs. I've be​en attempting to get the tachometer  to sync with ​the analog inputs first by following the example l​inked here. (https://decibel.ni.com/content/docs/DOC-10785) So far each time I run it I either get a timeout e​rror on the DAQmx read or a "Multiple sample clock​ pulses were detected" error (see attached image).  It seems if I slow the sampling rate way down to ​say 10 hz and ensure that the tachometer signal is​ over 800-1000 RPM (13-17 Hz) before starting the VI then the program will run without errors until ​the RPM drops below that threshold then the "Multi​ple sample clock pulses" error occurs.  The code is attached below.
    Does anyone know of a more effective way of syncin​g counter frequency inputs with analog inputs?  I'd like to have a VI that can show 0 RPM (and ev​entually 0 flow as well, but I think I need to fig​ure out the timing of one counter before I add ano​ther as it seems I can't have two counters in the ​same task). Any help on this would be greatly appr​eciated.
    LabVIEW version 13.0
    cDAQ-9178 Chassis with NI 9401 for the two counter inputs and NI 9205 for the analog inputs.
    Thanks!
    Richard
    Solved!
    Go to Solution.
    Attachments:
    SimpleDAQ.vi ‏44 KB
    LV_Error.JPG ‏31 KB

    Maybe third times the charm? 
    So I've finally got a good handle on why the VI is having problems at low RPM though I'm somewhat embarassed how long it took me to do that
    Because I have the counter time synced to my Analog input task if it doesn't see at least two pulses between the two clock pulses set by the analog input task I get the -201314 "Multiple sample clock pulses" error. This seems fine at first as it just sets a minimum RPM that I can measure and it's well below the area I'm interested in so no problems there.  I tried a simple error handler that would clear the error when it happend assuming the loop would keep iterating until the RPM went above that minimum at which point I would get a signal again. This is not the case, the read function just continues to spit out the -201314 error even after the RPM is back in the readable range. So then I tried adding two case structures so that when the error occured it would stop the task, clear the error, and then start the task again on the next loop iteration (Code Attached). This also doesn't work as the error shows up again on the stop task and then AGAIN on the start task on the next loop iteration. It seems this error is not actually being cleared and once it happens it stays with the task regardless of what the error cluster is carrying. 
    Anyone have any ideas?  The only solution I can think of is to just clear all tasks and recreate them each loop iteration until the RPM is readable again but that strikes me as a horribly clunky solution.
    Richard 
    Attachments:
    SimpleDAQ_1_Start Stop.vi ‏48 KB

  • I need advise and help with this problem . First , I have been with Mac for many years ( 14 to be exact ) I do have some knowledge and understanding of Apple product . At the present time I'm having lots of problems with the router so I was looking in to

    I need advise and help with this problem .
    First , I have been with Mac for many years ( 14 to be exact ) I do have some knowledge and understanding of Apple product .
    At the present time I'm having lots of problems with the router so I was looking in to some info , and come across one web site regarding : port forwarding , IP addresses .
    In my frustration , amongst lots of open web pages tutorials and other useless information , I come across innocent looking link and software to installed called Genieo , which suppose to help with any router .
    Software ask for permission to install , and about 30 % in , my instinct was telling me , there is something not right . I stop installation . Delete everything , look for any
    trace in Spotlight , Library . Nothing could be find .
    Now , every time I open Safari , Firefox or Chrome , it will open in my home page , but when I start looking for something in steed of Google page , there is
    ''search.genieo.com'' page acting like a Google . I try again to get raid of this but I can not find solution .
    With more research , again using genieo.com search eng. there is lots of articles and warnings . From that I learn do not use uninstall software , because doing this will install more things where it come from.
    I do have AppleCare support but its to late to phone them , so maybe there some people with knowledge , how to get this of my computer
    Any help is welcome , English is my learned language , you may notice this , so I'm not that quick with the respond

    Genieo definitely doesn't help with your router. It's just adware, and has no benefit to you at all. They scammed you so that they could display their ads on your computer.
    To remove it, see:
    http://www.thesafemac.com/arg-genieo/
    Do not use the Genieo uninstaller!

  • WIndows 8.1 printer error: windows cannot print due to a problem with the current printer set up

    My HP OFFICEJET 8500 PRO was working just fine wirelessly until I installed the Windows 8.1 update from the Microsoft.  Now I cannot print at all.  I get an error that says,  "windows cannot print due to a problem with the current printer set up".  I have tried reinstalling and a ton of other solutions to no avail.  Can someone PLEASE Help!

    Hello there, @jesseangelique ,
    Welcome to the Community!
    I would love to help you with the printing issue you're having, since the Windows 8.1 that was done.
    Please run the Print and Scan Doctor. Write me back with the results or post a screen shot of the results and I will have a look at them.
    This diagnostic tool will check for any conflicts that could be causing the issue. The tool will show you a report at the end. If there was a problem that the tool could not fix, you will notice it in the results.
    Also, let me know which Officejet 8500 Model you have:
     HP Officejet Pro 8500 All-in-One Printer - A909a
     HP Officejet Pro 8500 All-in-One Printer - A909b
     HP Officejet Pro 8500 Premier All-in-One Printer - A909n
     HP Officejet Pro 8500 Wireless All-in-One Printer - A909g
    Hope to hear from you!
    R a i n b o w 7000I work on behalf of HP
    Click the “Kudos Thumbs Up" at the bottom of this post to say
    “Thanks” for helping!
    Click “Accept as Solution” if you feel my post solved your issue, it will help others find the solution!

  • Problems with the posting period....

    Hi guys,
    every once in a while the old problem with the posting periods occurs. This morning it hit me and I went out to repair it.
    Starting out from MMRV I checked the open period and it said 062009.
    Using MMPV, by mistake, I opened 112009, so that I'm able to post to 112009 PLUS the previous period 102009 (which is ok so far). Later on I checked OB52 to see, if finance is not the problem. The opened period lasts from 012009 to 122009.
    Long story short: everything seems perfectly alright, however it still doesn't work. It says: Posting only possible in periods 2009/11 and 2009/10 in company code 1000
    I don't see where there could be a problem now...
    Any help is greatly appreciated!
    Thx & regards,
    Bobby

    Hi,
    It is possible to re-open a previously closed period. However, it is NOT advisable to do so because the valuation data of the previous period could be affected.
    In general, it is only safe to reopen a previously closed period when no material postings have been done after the period shifting to the new period.
    If there has already been postings after the period shifting to the new period, reverting the period back will cause database inconsistencies in the history tables.
    If you decide to proceed with this process, you can use the program RMMMINIT, but, please review the documentation of this program first!! and the check the SAP notes 487381 (for the error message that you are receiving) and the 369637 (for an explanation about the inconsistencies that will be generated.
    Steps are as below;
    Go to Transaction Code SE38
    Enter program name RMMMINIT
    Execute or press F8 function button
    Enter your company code (From and To)
    Enter relevant date: Say 01/10/2009 for Oct. 2009 month to be opened as of now
    That means, user can post for the month of sept 2009 as well as Oct. 2009
    Refer SAP Note No. 487381 for more details.
    As per SAP Notes 487381 ( If the periods are opened in advance in mmpv to again change it to current period the following process should be follow ), Go to Tcode MMPI, then go to menu bar and select system -> user profile->owndata.In that screen , under the parameters tab enter MMPI_READ_NOTE in Parameter ID field and enter, then under short description you will get Initialise period. Next Save.
    Again go to MMPI enter company code, period and year and execute.
    Other way of doing it is follow these steps: ( *TRY in Sandbox But do not try in PRODUCTION SYSTEM*)
    1. Use t.code: OX18, and delete the plants assigned to your CO.Cd and save.
    2. Use t.code: OMSY and change the posting period to the one u want and save.
    3.Go to OX18 and assign the plants you have deleted in step 1.and save.
    Regards,
    Biju K

  • Problems with the order

    once more I have problems with the order in iTunes:
    Titel number 8 is on top and the first one is on place 10. The only difference in the information is
    Titel number 8 has titel number 8 and the titel on place 10 has the titelnumber 1, all the other informations are eqaul..
    See the screenshots:

    applewoi wrote:
    the album has got 17 files in 2 CDs. Shall I write therefore
    Titelnummer
    1 von 17
    2 von 17
    and so on?
    all in 1 CD
    I suggest you set
    CD-Nummer
    1 von 2
    2 von 2
    Then the tracks
    CD-Nummer 1
    Titelnummer
    1 von 9 (or however many tracks there are per CD)
    2 von 9
    CD-Nummer 2
    Titelnummer
    1 von 8
    2 von 8

  • I had a problem with the hard disk on a 2010 macbook pro. Replaced the hard disk with an Hitachi 1TB and when I tried to erase and format It fails with input/output error. Any help much appreciated!

    I had a problem with the hard disk on a 13" 2010 macbook pro. Replaced the hard disk with an Hitachi 1TB disk but when I tried to erase and format, it fails with input/output error and at other times saying unable to allocate memory. Any help much appreciated!

    Zap the PRAM and Reset the SMC, then try again.

  • Problem with the input file format to be stored in database

    Hi,
    I am facing some problem with the input format. I am using the table name as data.employee. But i could not able to process the message forward. I am getting this error,
    com.ibm.db2.jcc.c.SqlException: java.sql.Connection.close() requested while a transaction is in progress on the connection.The transaction remains active, and the connection cannot be closed.
    Can you please help me prposing a solution for this format.
    Thanks,
    SOorya

    I think you are missing out the COMMIT operation.
    At the DB2 end before closing the connection if you do a 'COMMIT' then this may remove your error.
    i.e. after you close the Resultset>close the statement object> perform 'COMMIT' operation--> then close the connection.
    Also refer :-
    http://www.dbforums.com/archive/index.php/t-976407.html
    http://www.dbforums.com/showthread.php?t=1628183
    I hope this will help you.
    Thanks,
    Vijaya

Maybe you are looking for