BPC 7 MS. SPRUNCONVERSION ERROR..

Hi Dear Experts,
     We have created a new Application (consolidation type) from the appshell, its from the LegalApp apllication, but we have added new dimensions to it (USERDEFINED) . And we need to changed the name of the dimension so we copy the other dimension (Category, AcctDetail, IntCoL  ) rename it and modify the application. We have made all the requirements of a consolidation application including the Rate and Ownership Applications.
     Then were trying to make a currency conversion package, using the sprunconversion. but when try to run it the error says that:
SPRunConversion Version 7.0.112
Warning : Application without Flow Dimension
     But our application has already a subtable dimension.we have copied the acctdetail and rename it to AccountFlow and added it to our application.
Thanks,
Bennie Jay

Hi Garrett,
we are also working with Currency Conversion (CC) (in planning appset; not consolidation), also we are using no flow, but only posting results into an 'Destination Account' selected in the Business Rule Table. - so far translation runs well, and END - AVG is posted in the destination account.   (if that helps, let me know and i get into more detail)
As you are also working on the Business Rule Table. I was wondering if you mayhelp me out with some entry explanation. First of all I was hoping to get more detailed info on what the Fomula and other Entries in the Business Rule table may be, and what function they hold. (The obvious i know, but looking for answer to:
- Formula Field: What fomula's may be used to what extend; CC / CT in mind!
- Entity FX Type: What is this?
- Force Closing: I didn't see a change when selecting this.
- Periodic: What is the function for this, off and on.
- Destination Account (is there an option to clear this account, every time before every CC or CT ?
- Source & Destination Flow fields.
We are using Currency Translation (CT) to calculate the adjustment (btwn currency translated accounts). The difference is posted in the 'Destination Account'. - However when running CC / CT again the adjustment amount is added to the amount already caclualted. --- This does not seem right!
When running CC / CT a 100 times a day. 100 times the CT Adjustment amount will be posted on top of the amount already posted. - That still does not seem right!
Guys,
Any thoughts, solutions, understanding to the topic above. --- Your answer is apreciated. Thanks, Max

Similar Messages

  • BPC NW 7.0 error when accessing appset

    after installation, first time I go to admin console with user name administrator, password, I was able to get in admin console.
    however when I click "manage appset"  to change appset or copy appset "appshell" to my own appset, I got problem.
    I was asked to login again with user name and password.
    the error message I go is,
    Admin Load Failed.
    Public Member "'language" on type "XMLCreator" not found.
    I don't even know where this XMLCREATOR is.
    the error log is
    ==============[BPC Logging]==============
    [Message Type] : ERROR
    [Job Name]     : LogOn
    [DateTime]     : 10/27/2009 2:29:49 PM
    [UserId]       : SAP5\administrator
    [Message]       : ERROR:
    ManageAdminAppInfo response:
    <QUERY><RESULT><memberlookup><![CDATA[]]></memberlookup><srv_version><![CDATA[CATEGORY-1.012;C_ACCT-1.010;C_CATEGORY-1.011;C_DATASRC-1.007;ENTITY-1.008;FLOW-1.008;GROUPS-1.006;INPUTCURRENCY-1.008;INTCO-1.005;O_ACCT-1.004;P_ACCT-1.020;P_ACTIVITY-1.006;P_DATASRC-1.006;RPTCURRENCY-1.007;R_ACCT-1.007;R_ENTITY-1.006;TIME-1.020]]></srv_version></RESULT><ERRMSG><![CDATA[]]></ERRMSG></QUERY>
    ==============[BPC Logging End ]==============
    any idea?
    George

    Hi George,
    did you find any solution for the problem? I get a similar Error: "Public member 'ClearParameterNodes' on type 'XMLCreator' not found" when I try to start the Admin Client on a Windows XP system. It works perfect when I start the Admin Client on the windows server with the BPC 7.0 installation.
    Thanks,
    Peter

  • SPRUNCONVERSION ERROR - SAP BPC 10 MS

    Hi experts,
    I have a problem when execute SPRunConversion Version 10.0.7.0 PACKAGE.
    The process is executed 12 times (Twelve iterations). The result is correct, the rate is OK but the result is multiplied by 12.
    The log is show above:
    Executing stored procedure SPRUNCONVERSION [MODEL_NVA], [REAL],  [<NULL>],[GLOBAL], [SPSCOPE_338036],[SPLOG_686475]
    SPRunConversion Version 10.0.7.0
    Warning : Model without Flow Dimension
    10000170 - 8 Rows Calculated
    10000170 -  - 8 Rows Updated
    10000170 - 8 Rows Calculated
    10000170 - 8 Rows Calculated
    10000170 - 8 Rows Calculated
    10000170 - 8 Rows Calculated
    10000170 - 8 Rows Calculated
    10000170 - 8 Rows Calculated
    10000170 - 8 Rows Calculated
    10000170 - 8 Rows Calculated
    10000170 - 8 Rows Calculated
    10000170 - 8 Rows Calculated
    Any ideas? Any suggestions?
    Thanks
    Regards
    Eng. Martín D. Novachig

    Hi,
    why is it executed 12 times? What do you select when you run it, assuming you run it as a package from the datamanager.
    BR,
    Arnold

  • BPC MS 10 SPRunConversion at Group level

    Dear BPC Experts,
    We are implementing SAP BPC MS 10. SPRunConversion is running for each currency defined but its not running at Group level. I am getting errors FX-140 No Currency Available, sometimes i get FX-300 Timeid=20140700 - Nothing to extract from Fact - CLCFXTRANS... I have run FX conversion for the same timeid. Different errors if I change some parameter.
    FX rates are maintained. My SP is below:
    *RUN_STORED_PROCEDURE =
    SPRUNCONVERSION([Conso_FX],[ACTUAL],[INR],[GLOBAL],[%SCOPETABLE%],[%LOGTABLE%])
    *COMMIT
    Figures are getting converted into INR. Ownership and Scopes are maintained. I am unable to figure out the reason why N_SCOPE is not getting updated with Group so that i can proceed with IC Elimination.
    Can you please help with some pointers based on experience.
    Regards,
    Rajat Gupta

    Hi Arnold,
    I ran:
    *RUN_STORED_PROCEDURE =
    SPRUNCONVERSION([Conso_FX],[ACTUAL],[INR],[GLOBAL],[%SCOPETABLE%],[%LOGTABLE%])
    The system converted USD to INR.
    Then i ran:
    *RUN_STORED_PROCEDURE =
    SPRUNCONVERSION([Conso_FX],[ACTUAL],[S_CGM01],[GLOBAL],[%SCOPETABLE%],[%LOGTABLE%])
    *COMMIT
    S_CGM01 is a member from Scope dimension. I get "*ERROR* FX-300 Timeid=20110200 - Nothing Extract from Fact - CLCFXTRANS
    I checked the data is correctly maintained.
    Regards,
    Rajat Gupta

  • SAP BPC 7.5 Installation Error

    Hello All,
    We got a requirement to install the SAP BPC 7.5 on top of fresh machines with SAP BI 7.02 for our customer. As a part of installation and configuration process i have downloaded the SAP BPC Patches and installed on top of BI 7.02 with enhancement pack 2. created a new apshell Apshell whcih is default. the server was included in a DOmain XX. I also craeted the Dot Net server with domain user and which was included in admin group successfuklly. i was able to see the dot server manager diagnoistic green and successful. Now the real confusion starts.
    1. After installation of BPC DOT NET server on Windows 2003 server wich was already included in the domain now when i ca access the server http://localhost/osoft which is taking me to the screen sap bpc console and givig me a couple of options like
    1.Interfact to word
    2.interface to powerpoint
    3. Interface to excel
    4.Interface to web
    5.Administration
    when i click on administration it is taking me to second screen where it is askig me to select Appset in a small popup windows. There i dont have any popup to select where as it is leading to empty screen where there is no popup. when i click on ok then it will lead to again the main screen it have all the options interface to word,powerpoit etc..,
    I am really confused where i am missing ad whether i need to do anything else more for the same.
    I also see lot more in the installatio guide like select apshell.db9 etc where i am unable to see that option. i no where saw the file with name apset. I also saw in the some blogs and installation guide saying that to select the option install on top of mssql2005 where as i didnt see such an option anywhere.
    Can any one guide me o this where and what i am really missing.
    Edited by: Hemanth Kumar on Dec 25, 2010 5:18 PM

    Hi,
    This is one of the most common error I encountered during my recent BPC Project . This can be solved by the following ways.
    1.Please check the authorizations ( make sure to have full admin authorizations for the Apshell) .
    2.Make sure to Re- install both admin &  client tools (check the Diagnostics and uninstall  re-install both admin &  client tools once.)
    Regards
    CSM Reddy

  • BPC 4.2 Optimization error (object variable or with block variable not set)

    Hi All,
    I am getting the following error when I try to optimize application from the front end:
    Run-time error '91':
    Object variable or With block variable not set
    From the back end the optimization works just fine. This is the new application I created from the AppShell. As soon as I created this new application set, I tried to run optimization and I am getting this error. Optimization in the AppShell works just fine. I wonder what the problem is since this is a brand new application set. I tried a few things all day yesterday and day before but in vain.
    We are using BPC 4.2 (OutlookSoft CPM). Any help is greatly appreciated, the sooner the better.
    Thanks in advance!

    Depending on your version of 4.2, here are two possible issues and remedys.
    Possible issue #1
    Do you only have 1 application in the appset? - Add another application.
    Possible issue #2
    This problem will occur if you have copied 4.2 SP2 Apshell or copied an existing appset.
    This happens when a table named tblAdminTaskMessage exists and a stored procedure named INPUTMESSAGE does not exist.
    The table and stored procedure are created when you run optimize for the first time and when you make copy of Apshell that has been optimized once, it can copy the table but it cannot copy the stored procedures.
    The workaround is to delete the tblAdmintaskMesssage table in SQL Enterprise Manager within the problem appset.
    Hope this helps.

  • BPC 7.5 NW - Error Object variable or With block variable not set ?

    Hi, we have BPC 7.5 NW SP07.
    I am getting an error "object variable or with block variable not set" while trying to submit data through an Input schedule
    I went to the Excel Options --> Add-Ins --> COM Add-ins, disable and enable but not working.
    I look in ST22 some errors:
    TSV_TNEW_BLOCKS_NO_ROLL_MEMORY
    TSV_TNEW_PAGE_ALLOC_FAILED
    Error was initial in last days.
    Any idea ?

    Hi Vitoto,
    The problem is not with BPC Excel, but with Memory. I think there is no sufficient memory available in your system.
    Please check SAP Notes 20527 & 369726 for the dump that you are getting in ST22.
    Regards,
    Raghu

  • BPC standard Appshell copy error to another appset

    Hi,
    We have installed the BI and BPC 7.5 sps 05 for netweaver, Now we are going to copy the default appshell to another
    getting the abap dump and job was cancelled in BI.
    Could any one help us on resolving this issue.
    COPY_APPSET                                    BPC_ADMIN    Canceled
    01.04.2011 07:29:52 Copied dimension P_ACCT successfully                                                      UJA_EXCEPTION     209          S
    01.04.2011 07:29:52 Copied dimension P_ACTIVITY successfully                                                  UJA_EXCEPTION     209          S
    01.04.2011 07:29:52 Copied dimension P_CC successfully                                                        UJA_EXCEPTION     209          S
    01.04.2011 07:29:52 Copied dimension P_DATASRC successfully                                                   UJA_EXCEPTION     209          S
    01.04.2011 07:29:52 Copied dimension RPTCURRENCY successfully                                                 UJA_EXCEPTION     209          S
    01.04.2011 07:29:52 Copied dimension R_ACCT successfully                                                      UJA_EXCEPTION     209          S
    01.04.2011 07:29:52 Copied dimension R_ENTITY successfully                                                    UJA_EXCEPTION     209          S
    01.04.2011 07:29:52 Copied dimension TIME successfully                                                        UJA_EXCEPTION     209          S
    01.04.2011 07:29:52 Created Infocube /CPMB/LMIZA6K successfully                                               UJA_EXCEPTION     155          S
    01.04.2011 07:29:52 Created audit table successfully                                                          UJA_EXCEPTION     164          S
    01.04.2011 07:29:52 Created comment table successfully                                                        UJA_EXCEPTION     162          S
    01.04.2011 07:29:52 Created journal table successfully                                                        UJA_EXCEPTION     163          S
    01.04.2011 07:29:52 Created workstatus table successfully                                                     UJA_EXCEPTION     165          S
    01.04.2011 07:29:52 Copied Application PLANNING successfully                                                  UJA_EXCEPTION     210          S
    01.04.2011 07:29:52 Created Infocube /CPMB/LMIX0AO successfully                                               UJA_EXCEPTION     155          S
    01.04.2011 07:29:52 Created audit table successfully                                                          UJA_EXCEPTION     164          S
    01.04.2011 07:29:52 Created comment table successfully                                                        UJA_EXCEPTION     162          S
    01.04.2011 07:29:52 Created journal table successfully                                                        UJA_EXCEPTION     163          S
    01.04.2011 07:29:52 Created workstatus table successfully                                                     UJA_EXCEPTION     165          S
    01.04.2011 07:29:52 Copied Application RATE successfully                                                      UJA_EXCEPTION     210          S
    01.04.2011 07:29:53 Internal session terminated with a runtime error (see ST22)                                    00           671          A
    01.04.2011 07:29:53 Job cancelled                                                                                00           518          A
    Regards
    Kotesh

    Hi,
    Thanks for your reply, Please find the st22 dump below:
    Category               ABAP Programming Error
    Runtime Errors         MESSAGE_TYPE_UNKNOWN
    ABAP Program           UJA_COPY_APPSET_OPT
    Application Component  CPM-BPC-ADM
    Date and Time          01.04.2011 08:10:10
    Short text
         Message type " " is unknown.
    What happened?
         Error in the ABAP Application Program
         The current ABAP program "UJA_COPY_APPSET_OPT" had to be terminated because it
          has
         come across a statement that unfortunately cannot be executed.
    What can you do?
         Note down which actions and inputs caused the error.
         To process the problem further, contact you SAP system
         administrator.
         Using Transaction ST22 for ABAP Dump Analysis, you can look
         at and manage termination messages, and you can also
         keep them for a long time.
    Error analysis
         Only message types A, E, I, W, S, and X are allowed.
    How to correct the error
        Probably the only way to eliminate the error is to correct the program.
        If the error occures in a non-modified SAP program, you may be able to
        find an interim solution in an SAP Note.
        If you have access to SAP Notes, carry out a search with the following
        keywords:
        "MESSAGE_TYPE_UNKNOWN" " "
        "UJA_COPY_APPSET_OPT" or "UJA_COPY_APPSET_OPT"
        "START-OF-SELECTION"
        If you cannot solve the problem yourself and want to send an error
        notification to SAP, include the following information:
        1. The description of the current problem (short dump)
           To save the description, choose "System->List->Save->Local File
        (Unconverted)".
        2. Corresponding system log
           Display the system log by calling transaction SM21.
           Restrict the time interval to 10 minutes before and five minutes
        after the short dump. Then choose "System->List->Save->Local File
        (Unconverted)".
        3. If the problem occurs in a problem of your own or a modified SAP
        program: The source code of the program
           In the editor, choose "Utilities->More
        Utilities->Upload/Download->Download".
    Category               ABAP Programming Error
    Runtime Errors         MESSAGE_TYPE_UNKNOWN
    ABAP Program           UJA_COPY_APPSET_OPT
    Application Component  CPM-BPC-ADM
    Date and Time          01.04.2011 08:10:10
         Screen Line......... 6
         Debugger Active..... "none"
    Information on where terminated
         Termination occurred in the ABAP program "UJA_COPY_APPSET_OPT" - in
          "START-OF-SELECTION".
         The main program was "UJA_COPY_APPSET_OPT ".
         In the source code you have the termination point in line 69
         of the (Include) program "UJA_COPY_APPSET_OPT".
         The program "UJA_COPY_APPSET_OPT" was started as a background job.
         Job Name....... "COPY_APPSET"
         Job Initiator.. "BPC_ADMIN"
         Job Number..... 08080600
    Source Code Extract
    Line  SourceCde
        39       exporting
        40         i_module_name = uj00_cs_module-uja
        41       changing
        42         c_appset_id   = as_src
        43         cs_user       = ls_user.
        44
        45     create object lo_admin_mgr
        46       exporting
        47         i_appset_id = as_src.
        48     call method lo_admin_mgr->copy_appset
    Regards
    Kotesh

  • Uninstalling BPC  fails - Reporting server error

    Hi,
    I am uninstalling BPC 75 SP06,  as recommended I deleted all folders related to the tool such as:
    Control Panel - Uninstall clients  and Server
    C: - PC_MS folder
    desktop shortcuts
    C:> docs and settings > administrator > my documents >PC_MS
    C:> SAP Business Objects
    After this, I installed again the tool but the error "Cannot COnnect to reporting services server, check your server information".
    I havent changed anything !!
    Also trying to access to Reporting services inside SQL shows this:
    ===================================
    Cannot connect to BPCDEMO.
    ===================================
    The underlying connection was closed: The connection was closed unexpectedly. (Microsoft.SqlServer.Management.UI.RSClient)
    Program Location:
       at Microsoft.SqlServer.ReportingServices2005.RSConnection.GetSecureMethods()
       at Microsoft.SqlServer.ReportingServices2005.RSConnection.IsSecureMethod(String methodname)
       at Microsoft.SqlServer.ReportingServices2005.RSConnection.ValidateConnection()
       at Microsoft.SqlServer.Management.UI.RSClient.RSClientConnection.CreateConnection(String connectionString)
       at Microsoft.SqlServer.Management.UI.RSClient.RSConnectionInfo.CreateConnectionObject()
       at Microsoft.SqlServer.Management.UI.RSClient.RSConnectionInfo.RSTypeImpl.GetConnectionObject(UIConnectionInfo ci)
       at Microsoft.SqlServer.Management.UI.ConnectionDlg.RSType.GetConnectionObject(UIConnectionInfo ci)
       at Microsoft.SqlServer.Management.UI.VSIntegration.ObjectExplorer.ObjectExplorer.ValidateConnection(UIConnectionInfo ci, IServerType server)
       at Microsoft.SqlServer.Management.UI.ConnectionDlg.Connector.ConnectionThreadUser()
    What can I do?
    Please i need help ASAP
    Velázquez

    Hi Nilanjan,
    Thanx for the response.
    The Reporting Service is running, I installed it as "default installation" and everything seems to be ok, the Configure Report Server console shows everything green even Database Setup. Im using just 1 user (default and administrator) because it is a local  machine however I rtied to performs a test in the Database Setup tab and I selected "credentials type - windows , account name - administrator , password - xxx"   and it shows "there was a failure applying your change" it seems that the user is not appropiate and I have no idea why.
    I tried to reinstall Reporting Services but it doesnt seem to work, I have no idea what to do, please help.
    Velázquez

  • BPC 75M - Modify Application error "Cannot connect to the Reporting Server"

    I have trouble with Modify Application, also in ApShell. Maybe you have a clue what it can be the problem.
    Configuration: single server BPC 7.5M SP3, Windows Server 2008 SP2, SQL Server 2008 SP2
    Installation user is a domain user.
    No errors during installation, no error in Server Manager diagnostics.
    But when I try to modify an Application from BPC Admin it gives an error for step "Make OLAP database and Journal/Audit reports. / Validate dimension formulas.".
    In tblLogs I see the error message:
    ==============[System Error Tracing]============== [System Name] :
    AdminServerHandler [Message Type] : ErrorMessage [Job Name] :  
    AdminApplicationHandler : ExecuteModIfyApplication [DateTime] :
    10/19/2010 1:19:13 PM [UserId] : MYDOMAIN\MYUSER
    [Exception] DetailMsg : {System.Exception: Cannot connect to the Reporting Server at
    OSoft.Services.Application.AdminMainServer.AdminApplicationHandler.SetChangeDimensionForAudit(String strAppset, String strApp, String  strUserID, Boolean blnIsChangedDimension, String& strErrMsg) at
    OSoft.Services.Application.AdminMainServer.AdminApplicationHandler.ExecuteModIfyApplication(String strAppSet, String strApplicationName, String strApplicationDescription, String strSourceApplicationType, String 
    strNewApplicationType, String strRateApplicationName, String
    strOwnerShipApplicationName, String strCurrencyConversionsCalculation, 
    String strCalculation, String strIntercompanyBookings, String  
    strUSEliminations, String strOpeningBalance, String strValidations,
    String strIntercompanyEliminations, DataTable dtDimensionList, Boolean 
    bReassignSQLIndex, Boolean bProcessApplication, Boolean bDeleteFact,
    String strChangeAppType, String strUserID, String strReportBackID)}
    ==============[System Error Tracing End ]==============
    Edited by: Alexandru Berindei on Oct 26, 2010 7:57 PM
    Edited by: Alexandru Berindei on Oct 26, 2010 7:58 PM

    There were problems accessing the web page   HTTP://server/reports
    Error message:   "Reporting services 2008 user does not have required permissions"
    It was possible to open the page  HTTP://server/reports with local administrator user and  I fixed this problem by performin following:
    - add Content Manager right to bpc installation user
    - disable UAC from Windows Control Panel  > User Accounts
    Still Modify Application gives the same "Cannot connect to Reporting Services".
    I tried:
    - check that BPC Installation User is part of Local Administrators
    - reboot server
    - reinstall BPC after disabling UAC
    - reinstall everything except the Windows Server 2008
    - I installed another computer with the same exact configuration but with a local BPC Installation User and it works.
    Have anyone installed BPC 7.5M SP3 on single Windows Server 2008 SP2 , with SQL Server 2008 SP2 and with BPC Installation user a domain user?
    Maybe you have an idea of what I should check next.
    Thank you,
    Alex

  • BPC 7.0 installation error during creation Apshell db

    Dear all,
    I've tried to installed SAP BPC 7.1 on multi server environment (OLAP Server, Microsoft SQL Server, Microsoft SQL Reporting Services, Insight OLAP server in a windows 2003 64 bit server and Application server, File Share, Web Server in a w2003 32 bit server).
    When installation start it goes fine until steps : "Create sample appset database".
    Datbase AppServer has been created without errors (access to database server seems to be right with domain user used during installation).
    The error is:
    "Error (A file activation error occured. The physical file name 'Cannot open database "Master" requested  by the login. The login failed .\DATA\ApShell.mdf' may be incorrect. Diagnose and correct additional errors, and retry the operation.).
    I've checked sql server log file and I've found this error:
    2009-07-16 16:55:16.40 Logon       Error: 18456, Severity: 14, State: 16.
    2009-07-16 16:55:16.40 Logon       Login failed for user 'SABAF\icms'. [CLIENT: 172.25.20.37]
    2009-07-16 17:29:51.05 Logon       Error: 18456, Severity: 14, State: 16.
    2009-07-16 17:29:51.05 Logon       Login failed for user 'SABAF\icms'. [CLIENT: 172.25.20.37]
    2009-07-16 17:29:51.14 Logon       Error: 18456, Severity: 14, State: 16.
    2009-07-16 17:29:51.14 Logon       Login failed for user 'SABAF\icms'. [CLIENT: 172.25.20.37]
    2009-07-16 17:29:51.23 spid79      Error: 5105, Severity: 16, State: 2.
    2009-07-16 17:29:51.23 spid79      A file activation error occurred. The physical file name 'Cannot open database "Master" requested by the login. The login failed.\DATA\ApShell.mdf' may be incorrect. Diagnose and correct additional errors, and retry the operation.
    2009-07-16 17:29:51.23 spid79      Error: 5105, Severity: 16, State: 2.
    2009-07-16 17:29:51.23 spid79      A file activation error occurred. The physical file name 'Cannot open database "Master" requested by the login. The login failed.\DATA\ApShell_Log.ldf' may be incorrect. Diagnose and correct additional errors, and retry the operation.
    It seems there was an error during login.
    The installation log file is reported below:
    Installation Date: 7-16-2009, 17:26:35
    User Information: SABAF\icms
    Server Information:
         BPC Version: 7.0.113
         SQL Version for BPC: 2005
         SQL Server: ERPSAKPPR01
         OLAP Server: ERPSAKPPR01
         Insight OLAP Server: ERPSAKPPR01
         Reporting Services Server: ERPSAKPPR01
         Application Server: ERPSABPC01
         Web Server: ERPSABPC01
         Data Path: E:\BPC\Data
    Installation Status
         Diagnostics: Done
         File copy: Done
         Crypto-file[AmyuniPDF.exe] information: E:\CD_INST_BPC_7.0\AmyuniPDF.exe
         Crypto-file[XceedZip.dll] information: E:\CD_INST_BPC_7.0\XceedZip.dll
         Starting WWW Services: Done
         Configuring Internet Information Server: Done
         Install .Net assemblies in the Global Assembly Cache: Done
         Assigning COM+ Components: Done
         Create AppServer Database: Done
         Create Sample Database: Error
         Create Sample OLAP Database: Error
         Setup Management console: Error [There is already an object named 'sp_ActivePages' in the database.]
         Starting BPC Send Governor Service: Done
         Starting BPC Insight Service: SKIP
    If I try to connect with SQL Server Management Studio with windows authentication (same user of installation) and permissions are ok.
    Any idea ?
    Thanks
    Maurizio Manera

    Hi Steven,
    If this is the case, I think you would need to configure the access rights in your db security for BPC admin user. Hope this help you.Good luck

  • BPC 7.0 Install error - Cannot connect to SQL server

    Hi,
    I am in the process of installing BPC 7.0 and encountered the following error after filling the "Advanced settings" details on the server info screen:
    *Cannot connect SQL server.
    Please check the SQL server connection or check System Admin ID to access the sql server.*
    I know that the System Admin ID I provided in the previous (service type accounts) screen is correct. What am I missings? Appreciate the help asap!

    BPC installation user has to be SysAdmin into SQl Server.
    Also make sure that SQL Server was installed having Windows authentication enable otherwise the connection to SQL Server can not be establish.
    Into Application Server (the server where you are trying to install BPC) open Management Studio and see if you can connect to SQL Server.
    Are you using special ports or instances fro SQL Server?
    Please make sure you are providing all these information into BPC setup.
    Regards
    Sorin Radulescu

  • Install BPC for Office memory error

    Hi, I have a Windows 7 workstation with 8Gb of RAM.  When I try to install BPC for Office, I get the following error:  'Not enough memory.  A minimum of 64 MB of memory is require."  How do I get around it?

    Hi
    As per Sorinu2019s response, until 7.5 there is no official support for Windows 7 or 64-bit operating system.
    However, with that said, if you still wish to progress at your own risk, then you can do so.
    You will first need to get Microsoft .Net 1.1 (32-Bit) installed and configured.
    Then you can install BPC client. However, you cannot install the client from the OSOFT WebPage, else you will receive 'Not enough memoryu2019 error.
    You will need to copy the two executables for the client installation (EverestAdmin and EverestClient) to the client PC and install by running these executables. You must be logged onto the client PC as an account with full local Administrator privileges, and you must also be logged in as an account with full local Administrator privileges for first logon to BPC Admin and BPC Office client.
    Be aware that certain functionality may not work as expected, for example PDF Publishing.
    Regards
    Shaam

  • BPC 7.5NW consolidation error

    Hi,
    We are using BPC 7.5 NW version (7.50.04). We changed standard dimension 'GROUPS' to dimension type 'R' and included it in our legal applications.
    We are using below logic to run both currency conversion and legal consolidation.
    *RUN_PROGRAM CURR_CONVERSION
          CATEGORY = %C_CATEGORY_SET% 
          GROUP = %GROUPS_SET%
          TID_RA = %TIME_SET%
          RATEENTITY = GLOBAL
    *ENDRUN_PROGRAM
    *RUN_PROGRAM CONSOLIDATION
        CATEGORY = %C_CATEGORY_SET%
        GROUP = %GROUPS_SET%
        TID_RA = %TIME_SET%
    *ENDRUN_PROGRAM
    The standard data manager package with process chain 'LEGAL_CONSOLIDATION' fails with error message 'Member "G_CG2" not exist'. G_CG2 is a member of GROUP dimension. When we executed the below logic (with hardcoded variables) in BW transaction UJKT, it worked fine and posted values correctly.
    *RUN_PROGRAM CURR_CONVERSION
          CATEGORY = C_100
          GROUP = G_CG2
          TID_RA = 2008.DEC
          RATEENTITY = GLOBAL
    *ENDRUN_PROGRAM
    *RUN_PROGRAM CONSOLIDATION
        CATEGORY = C_100
        GROUP = G_CG2
        TID_RA = 2008.DEC
    *ENDRUN_PROGRAM
    Any idea, why system is not able to recognize 'G_CG2' when we use data manager package? In BPC 7.5NW, is it mandatory to use both 'R' and 'G' type dimensions? SAP Help has different contradictory views !!!

    Hi Nilanjan,
    We are using 'GROUPS' dimension of type 'R'.
    The above dimension has members of both GROUPS and CURRENCY (ex: G_CG1, G_CG2, LC, USD etc).
    1) Run currency translation for 'USD'. The logic works fine if i change it as follows:
    *RUN_PROGRAM CURR_CONVERSION
    CATEGORY = %C_CATEGORY_SET%
    CURRENCY = %GROUPS_SET%
    TID_RA = %TIME_SET%
    RATEENTITY = GLOBAL
    *ENDRUN_PROGRAM
    2) Run currency translation for 'G_CG2'. The logic works if i change it as follows:
    *RUN_PROGRAM CURR_CONVERSION
    CATEGORY = %C_CATEGORY_SET%
    GROUP = %GROUPS_SET%
    TID_RA = %TIME_SET%
    RATEENTITY = GLOBAL
    *ENDRUN_PROGRAM
    3) Run COI for 'G_CG2'. The logic works if i change it as follows:
    *RUN_PROGRAM CURR_CONVERSION
    CATEGORY = %C_CATEGORY_SET%
    GROUP = %GROUPS_SET%
    TID_RA = %TIME_SET%
    RATEENTITY = GLOBAL
    *ENDRUN_PROGRAM
    4) The logic is executed successfully from BW UJKT if i hardcode the values for 'GROUPS' dimension.

  • BPC 7.0NW installation error

    Hi,
    In BPC server diagnosis, we are getting an error 'Current User Name does not have permission for Administrators group. - Incorrect' when we try to install BPC 7.0NW. We get this error when we try to install BPC. The user has full admin rights. Still we are getting this error. We uninstalled and tried couple of times. But we are not able to move ahead. Please suggest.
    regards,
    Lokesh Nandula

    Hi
    Please make sure that the account that is used for the installation is a member of Local Admins in Windows on the .Net server. It should be explicitely listed in that group (as opposed to a nested group membership)
    best regards,
    Bruno Ranchy

Maybe you are looking for

  • Viewing 16:9 on an ntsc montor

    I was given a last-minute video piece to construct from a series of stills. The C.D. gave me the sequence and stills already thrown together. I opened it up and played it and the stills are being squashed on my NTSC monitor because somehow they are n

  • Think you need a rant section

    I would just like to say that I believe this board would be awesome if it had a section for Verizon customers to give Verizon input on what they would like to see in the future. I mean come on I have been a Verizon customer for as long as I can remem

  • Generating DME format by executing F110

    Hi As per the bank requested, we have an developed and Data Medium Engine format using DMEE. After executing the payment run, I had downloaded the output of the file using Environment --> Payment Medium  --> DME Administration When i go into Environm

  • InDesign spell check and apostrophes

    I'm trying to spell check a long document, and the most frustrating thing is that the spellchecker stops at words or names with apostrophes but doesn't add them to the dictionary. Can anyone out there advise me how to do this? Thanks in advance. Pete

  • Macbookpro noise issue on right side with heat