BPEL Pick and Wait activity for Synchronous Process

Hi everyone,
Is it possible to use the pick and wait activity in bpel for recieving the synchronous webservices response .I need to invoke a synchronous webservice and want to use the pick activity onmessage branch to recieve the response of the synchronous webservice. I have tried the pick activity to recieve the response of asynchronous bpel process it is working fine.Now if i want to use the pick activity to recieve synchronous webservice response is it possible ?
If someone can help me in this regard it would be great.
Thanks in Advance.
Regards,
Senthil Kumar.A

that's the thing , you can't
You must create another bpel (sincr ) in front of your asincr(bpel)
the sincr bpel will have a pick activity on the onResult(or onError) message from the asinc bpel. You pass the payload from OnResult to output and voila.
The asincr bpel will have at least 3 operations .
1. operation -
2.onMessage
3.OnResult
(4.OnError )
Be carefull how you put the roles and port types in the wsdl file. The callback must be first.
<portType name="xCallback">
<operation name="OnResult">
<input message="ns1:xResponseMessage"/>
</operation>
<operation name="OnError">
<input message="ns1:xFaultMessage"/>
</operation>
</portType>
<portType name="x">
<operation name="process">
<input message="ns1:xRequestMessage"/>
</operation>
<operation name="OnMessage">
<input message="ns1:xResponseMessage"/>
</operation>
</portType>
<plnk:partnerLinkType name="x">
<plnk:role name="xProvider">
<plnk:portType name="client:xCallback"/>
</plnk:role>
<plnk:role name="xRequester">
<plnk:portType name="client:x"/>
</plnk:role>
</plnk:partnerLinkType>

Similar Messages

  • How to implement wait activity in OWB process flows?

    Hi,
    I am using OWB 10G R1.
    There is no wait activity in process flows.
    My scenario is, whenver a trigger file is created, I want to proceed with the process flow. If the trigger file doesnot exist, then I want to put the process flow in a wait state, until the trigger file is created.
    Here I used File_Exists activity. But it is checking for the file only once. And it returns warning.
    After that, I want to add an wait activity for certain period of time. How can I do this? Is there is any package,procedure or function to do that?
    Any help is appreciated.
    Thank you,
    Regards,
    Gowtham Sen.

    Gowtham,
    Well the following hint is provided by oracle warehouse builder help.........
    The time-out setting for the workflow engine determines how long the File Exist activity waits for a file. If the file does not arrive before the time-out setting expires, the File Exists activity terminates with errors.
    well someone with deep workflow knowledge can answer this one...
    If you get the answer please share with us.....
    Regards,
    Suraj.

  • Err:Internal Job Queue full for synchronous processing of print requests

    Hi,
    We are getting a lot of errors in system log with the
    error :
    Internal Job Queue full for synchronous processing of print requests.
    User :SAPSYS
    MNO:FBU.
    When we check the document in syslog it states it can be solved by reducing the print load or increasing performance or if there is a connection problem to host spooler , by improving the transfer of data to host spooler..
    But not by increasing the no of spool workprocess..
    I think any of the one stated cannot be implemented ..
    Pls provide your valuable answers and if any of the above can be implemented from your end..
    Regds,
    Satyanarayana N

    Hi Vamshi,
             Thanks for your response but would also like to confirm how we can say that spool queue is full and what may be the Max size of spool queue..
    When we say Internal queue is full does it mean spool queue...
    And also when I run the TEmse consistency check it is giving some errors..
    When I check Spool requests there are some waiting process,but when I check Output requests there are only 1 or 2..
    Please provide  me your valuable solution regd this..
    Regds,
    Satyanarayana N.
    Regds,
    Satyanarayana N.

  • FBU Internal Job Queue Full for Synchronous Processing of Print Requests

    Hello All,
    We are getting a lot of errors in system log (SM21) with the
    Error : FBU Internal Job Queue Full for Synchronous Processing of Print Requests
    User :SAPSYS
    MNO:FBU
    =============================================================
    Documentation for system log message FB U :
    If a spool server is to process output requests in the order they were
    created using multiple work processes, the processing of requests for a
    particular device can only run on one work process. To do this an
    internal queue (limited size) is used.
    If too many requests are created for this device too quickly, the work
    process may get overloaded. This is recognized when, as in this case,
    the internal queue is exhausted.
    This can only be solved by reducing the print load or increasing
    processor performance or, if there is a connection problem to the host
    spooler, by improving the transfer of data to the host spooler.
    Increasing the number of spool work processes will not help, as
    requests for one device can only be processed by one work process. If
    processing in order of creation is not required, sequential request
    processing can be deactivated (second page of device configuration in
    Transaction SPAD). This allows several work processes to process
    requests from the same device thus alleviating the bottleneck.
    Enlarging the internal queue will only help if the overload is
    temporary. If the overload is constant, a larger queue will eventually
    also be overloaded.
    ===========================================================
    Can you please tell me how to proceed.
    Best Regards,
    Pratyusha

    Solution is here:
    412065 - Incorrect output sequence of output requests
    Reason and Prerequisites
    The following messages appear in the developer trace (dev_trc) of the SPO processes or in the syslog:
    S  *** ERROR => overflow of internal job queue [rspowunx.c   788]
    Syslog Message FBU:
    Internal job queue for synchronous request processing of output requests full
    The "request processing sequence compliance" on a spool server with several SPO processes only works provided the server-internal job queue (see Note 118057) does not overflow. The size of this request queue is prepared using the rspo/global_shm/job_list profile parameter. The default value is 50 requests. However, if more output requests arrive for the spool server than can be processed (and the internal request queue is full as a result), more SPO processes are used to process the requests (in parallel), and the output sequence of the requests is no longer guaranteed.
    Solution
    Increase the rspo/global_shm/job_list profile parameter to a much larger value. Unfortunately, the value actually required cannot be found by "trial and error" because this queue contains all the incoming output requests on a spool server, not just the "sequence compliant" requests. A practical lower limit for this value represents the maximum sequence-compliant output requests for the above generated output device. If, for example, 1000 documents that should be output in sequence are issued from an application program to an output device, the queue must be able to hold 1000 entries so that it does not overflow if the SPO process processes the requests at a maximum low-speed.

  • What is diff b/w pick and switch activity in bpel?

    what is the difference between pick activity and switch activity in BPEL? example Please

    1)The switch activity is an IfElse with two different flows, based on a conditional expression, derived out of existing message(s) in your process.
    Eg. i) Whether the salary is greater than 10,000 or not.
    ii) Whether the age is greater than 60 or not.
    iii) whether the department is finance or not.
    2)The pick activity is an IfElse with two different flows, based on two different messages/signals, that you can expect to receive(when you are waiting for a message) from outside of your process.
    Eg. i) whether you received a reply message or a timeout signal.
    ii) whether you received a AddNewEmployee message or UpdateEmployee message.
    The (decision for which route to be taken for) pick activity is based on the MessageType, while the switch is based on the contents in a message. The pick activity implies that you are waiting for a message, this can occur, at the start of your process or in the mid of your process. However, switch activity doesnot wait for any message, hence can only occur in the mid of the process and can not be the start of a process.
    Mark the posting appropriately as "helpful" or "correct answer", if your issue is solved.

  • Workflow activation for HCM process

    Hi Guys,
    I have gone through few threads regarding this but couldn't solve the problem...my requirement is to activiate wf for HCM process(we are on ECC.6) ..in process config i have assigned standared wf and then activited that but the problem is i can not see any event triggered(in SWEL) once we save and send the form..any specific config to be done for triggering event.
    Thanks,
    Atul

    Please check whether the Event Trace is activated from SWELS transaction Code. After that also check whether any restriction has been imposed in this transaction.
    You can just create a event from SWUE and check whether entries are getting registered in SWEL tcode
    Thanks
    Arghadip

  • Message Wait Activity Or Notification Wait Activity for Web Service Wait

    Hi,
    I have a Message Wait Activity Or Notification Wait Activity which waits for a message from my Web-Service. But this Activity keeps on waitinf for the message even if the web-service is down. How do I make it invoke a System Exception if the web-service is down or the web-service cannot be connected?

    Hi,
    I suspect you've put a lot of thought into this and decided to take this approach, but could you describe why you're thinking your web service might be down frequently enough to do this?
    Here's one approach to having the Message Wait activity discover when something outside its control occurs. Put the Message Wait activity inside of one of two transitions going through a Split/Join. For the other transition going through the Split/Join, add a Timer activity (if you are using Oracle BPM 10g). Set the Timer activity to some period that you want to use to periodically hit the web service to ensure it is up (e.g. '5m' to test to see if the web service is up every 5 minutes). Don't have this occur every few seconds or your Engine's performance will be degraded.
    From the Timer activity there would be one transition. This transition leaving the Timer activity would be an unconditional transition going to an Automatic activity. This Automatic activity would have an unconditional transition going back to the Timer activity, and a conditional transition going to the Join activity. The logic in the conditional transition leaving the Automatic activity could be just a single boolean instance variable (e.g. "wsDown"). When the Automatic activity discovers that the web service is down, this copy of the work item instance will flow to the Join activity.
    The logic in the Automatic activity will invoke a dummy web service running on the same machine you're worried about. If an exception is thrown and caught inside the Automatic activity indicating the web service is down, you'd set a boolean flag "wsDown = true".
    The Join activity would have the logic:
    this = copy
    action = RELEASE If the "wsDown" instance variable is set to true when it leaves the Join activity, then the web service was down and the Message Wait activity was never notified from the outside web service.
    Hope this helps,
    Dan

  • How to check actual allocated and used memory for java process in solaris?

    Hi,
    I'm testing performance for java application on solaris 10. And I would like to know how to measure actual memory allocated and used for java process.
    I'm setting -Xms512m -Xmx512m for my java process and I use prstat command to monitor it's memory. But I found that when I run prstat to check, in SIZE column is more than I setting (found 644).
    So I'm don't know the actual memory that java process used. (In this case,is it mean the process use memory (644) more than setting (512)?)
    Thank you.

    With Xms/Xmx you specify the Java heap size. On top of that comes the permanent generation (default max size 64m) and the C part of the process (the JVM itself with all its libraries and data).
    With "ps -e -o pid,vsz,rss,args" you get the virtual and set resident size of your processes.
    Nick.

  • Data filtering not activated for ALE processing of Outbound Deliveries

    Dear all,
    we're currently upgrading from 4.6c to ERP 6.0 and are facing a serious problem with our IDoc interfaces:
    In 4.6c, data filtering for Message Type SHP_OBDLV_SAVE_REPLICA was activated and use to extract some segments from the IDoc sent to our logistics provider.
    In ERP 6.0 data filtering is not activated for SHP_OBDLV_SAVE_REPLICA and we do not know how to activate it. For some reason, we can still see the data filtering setting when we switch to "system view" in BD64 but we're not able to change it.
    Checking filter settings in the old system using transactions BD60, ... we do not see any clue how data filtering or filter objects have been defined for SHP_OBDLV_SAVE_REPLICA.or in it's context
    Help please - thank you very much in advance,
    Martin Pluntke

    Dear all,
    thank you for your help. I've just realized that the former project team made a modification to object LIKP, method SAVEREPLICA in transaction BDBG and set it to "Data filtering allowed".
    This setting was lost during upgrade.
    Last question: When redoing this modification (I hate to do this but that's the only way to keep the interface running) and save it I get an error/warning message during generation that the definition is inconsistent. I can continue the generation or cancel it. However, the switch is activated and my filter settings suddenly appear again in BD64 (they've been there all the time, but not displayed or active).
    Is there anything I've to keep in mind? Can I generate, should I ignore?
    Thank you all for your help,
    Martin
    Edited by: Martin Pluntke on Feb 8, 2008 4:37 PM

  • Steps to Configure Port and Partner Profile for Outbound process

    Hi,
    I want to Configure the partner profile and Port definition for outbound Message type REMADV ( for Vendor). 
    Could anyone please tell me the steps to configure.
    Thank you,
    Renu

    Hi Renu,
    In partner profile we define the system which are going to communicate between themself and send data, here we give some logical name for the system which are going to be partners in data communication.we set it using WE20
    Port is a medium through which we send the data it connect one system with the system in other end its unique, depend on the scenario we use diff ports like file port(EDI) transactoional port(ALE) internet port(for internet apl), like this i dont remember all the name, so according to our application type we select the ports we set port using WE21 usally tport name start with A*** something like this. withour defining a port we cant communicate with other system its the linker b/w the 2 system.
    <b><u>For more information please refer the following links:</u></b>
    http://help.sap.com/saphelp_nw04/helpdata/en/3b/beb13b00ae793be10000000a11402f/content.htm
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/4943f2b7-0a01-0010-37af-faff35b2f08c
    Regards,
    Moqeeth

  • IMessage and FaceTime are waiting activation for two days

    Hi, two days ago I changed my ‘self-cut’ sim-card to nano-sim art my carrier office.
    For 20 days before that iMessage and Facetime worked perfectly fine with two different carriers, they activated normally.
    But after the moment I put new sim-card into iPhone it just quit working. It's always ‘waiting for activation’ on my phone number (works normally with e-mails though).
    It's mostly iMessage I'm worried about.
    I've tried:
    1. Turn off iMessage, reset network settings, turn off the phone, turn on the phone, turn on iMessage;
    2. Turn off iMessage, check that ‘My Info’ in Mail, Contacts and Calendars is correct, turn on iMessage;
    3. Reset to the factory settings, after that — I've tried to activate it on ‘clear’ device, same result, so I recovered all my info from the backup.
    4. Went to my carrier office, changed three sim-cards (1 — nano-sim, 2 — micro-sim, which I cut, 3 — nano-sim again), no result.
    5. Put my latest sim-card into other iPhone 5 — no activation in 5 minutes.
    6. Put another sim-card of this carrier into my iPhone — no activation in 5 minutes.
    I'm already desperate here, my carrier says ‘you have to ask Apple Support’, Apple Support is on answermachine that says ‘ask your carrier’, I just need my iMessage working normally

    Hello, I can understand how frustrating this is.
    I spoke to Apple just now, and they're aware. There's no solution, except to wait it out. Because of the 5s launch and iOS 7, Apple's servers are supposedly being hammered. A more senior Apple rep thought there will be delay up to 48 hours.
    I have a 5s, and so does my friend. We both have the same issue as you.
    This article may be helpful, just in case:
    http://www.igeeksblog.com/fix-imessage-waiting-for-activation/
    Fingers crossed.

  • Can schema validation be activated for a process instance?

    Is there some configuration property that can be added to the bpel.xml that will turn on schema validation for a single process (as opposed to turning this on for the entire engine)?
    Cheers,
    -Dustin

    Hi Dustin ,
    You can also use the same property in bpel deployment descriptor's partnerLinkBinding, to enable/disable xml validation for a particular partner. "validateXML" property in bpel dd will override the domain.xml's "validateXML" property.
    For example in LoanFlow/bpel.xml, enable validation for only StarLoanService partner:
    <partnerLinkBinding name="StarLoanService">
    <property name="wsdlLocation"> http://<hostname>:9700/orabpel/default/StarLoan/StarLoan?wsdl
    </property>
    <property name="validateXML">true</property>
    </partnerLinkBinding>
    HTH.
    Thanks,
    Rakesh

  • Need Urgent Help : Using VIVADO Design Suite for PCI Express 3.0, 8 lane, and AXI Interfaces for Video Processing

    My scenario is as follows :-
    1) I am building a Image Processing Application and using VIVADO HLS for that.
    2) I have synthesized my design using VIVADO HLS, and export it as IP-XACT format.
    3) I have imported it in VIVADO Design Suite, and added to the IP catalog, in a new project created.
    4) Since I am building an image processing pipeline, I am using AXI Stream interfaces, 1 input stream, and 1 output stream, and mentioned that in the HLS tool itself..
    5) I have a Virtex 7 690T FPGA, and have accordingly chosen the board throughout the HLS process, and the project.
    6) We want to use a PCI Express 3.0, through DMA access to the CPU.
    7) Now I am stuck here regarding how to proceed forward, I have gone through most of the Xilinx documentation, but am still not clear about what to do from here on.
    8) There are these 3 variables for me, AXI Stream Interface, DMA, PCI Express 3.0, all I have right now is the IP of the Image Processing pipeline that I generated through VIVADO HLS.
    9) Also at a later stage we would like to stream in Video, and process it through our image processing pipeline.
    Please help me with an overview of steps that I need to follow to get my design together and working on a real FPGA hardware with my Computer(windows OS), as in what Xilinx IP blocks do I need to use, how will I be able to exploit the maximum bandwidth from the PCI Express Interface in my specific case of send image through a stream, what tools will I need to use at every stage.
    I would be highly grateful if you guys can help me, we have a dealine to meet.
    Please let me know if we need any extra information.
     

    School project?

  • Download and store file for later processing

    Hi
    Is this possible without using the FileConnection API:
    1. Download an archive (XML-File with images) from a webserver and store it into RMS
    2. Read the archive later and open it
    3. Store the contents of the archive into RMS and delete the archive
    4. Process the XML with a parser
    5. I am lucky
    Kind regards
    Mic.

    Hi
    I must confess that I don't see the utility of the FileConnection API in your situation. When you speak of RMS then the JSR 75 has no use at all. Using RMS you provide a 'universal' solution to storing data in any Java enabled mobile phone.
    So, you would need knowledge of: HTTP communication (http://java.sun.com/developer/J2METechTips/2001/tt0820.html), RMS (http://developers.sun.com/techtopics/mobility/midp/articles/persist/) and XML parsing (http://developers.sun.com/techtopics/mobility/midp/articles/parsingxml/)
    Mihai

  • Find disk and network IO for each process

    Hi,
    In WMI, i seek the way to get informations we can see in disk and network tab in the resource monitor.
    in find PerfFormattedData_PerfPro_Process but we can only have all IO access not for each type of IO.
    I have to do that in C++ not managed.
    Thanks by advance for all informations you can give to me.
    Regards.

    Hi Ice02 - I believe this question would be better posted in the following MSDN forum:
    https://social.msdn.microsoft.com/Forums/en-US/home?forum=wptkv5&filter=alltypes&sort=lastpostdesc

Maybe you are looking for

  • Photoshop CC 2014 incompatible with Wacom tablets?

    Hey everyone, so I'm having a lot of issues with my Wacom tablets and PS CC 2014. So, I have two tablets hooked up to my computer (and before you ask, no, the issues don't stem from two tablets being connected to the computer. I already tested that.)

  • Partially Dead Computer for a Hard Drive Dump

    So my friend's computer died (kinda) and he was told he needs to dump the hard drive and re-install the OS. However, he would obviously like to save all the things that are on his hard drive, but we haven't been able to boot up onto anything that has

  • DISPLAY UNDEFINE TABLES IN SQL PLUS

    i am using Oracle 10g for last 1 week i seen unrecognized table names in my user while i issue following command SQL > select * from tab; table name like ......BIN$ and many other characters after it... i cannot drop that table also from DBA studio a

  • JMF- Problem in inbuilt Webcam using JMStudio

    Hi All, I am using Java Media Framework 2.1.1e and I am currently facing issues while accessing my inbuilt webcam using JMStudio I have tried to access my in-built Web-Camera from JMStudio app(of JMF..File->Capture->check 'Use video device'-> Press '

  • Parallels; Installing Windows XP

    You may find that, after installing the Parallels Desktop and following the directions to create a Virtual Machine and install Windows XP from a CD, the Parallels installer (console window) keeps generating error messages, referring to various corrup