Broken RAID 1 Mirror

I have uncovered today that my RAID 1 10.4.11 G5 server has had the mirror break sometime before or when I did the the upgrade from 10.4.10 to 10.4.11. I've been looking around, and I can't seem to find direction on how to properly 'break' the mirror.
I'd like to 'break' the mirror so I have 1 good drive, then clone the drive, and re-establish the mirror. Can someone point me in the direction of some documentation or guide me through that process?
At the moment I'm scarfing up a copy of the data so if 'really bad things' happen, we'll not be waiting too long to restore and repair things. It's always good to have an 'extra' copy of your backup!
Thanks for the help!

Hi
The way I would do this would be to remove the internal RAID 1 Set (both drives). I'm guessing the current RAID set contains everything? OS and Data? Install one of them in an external drive case. They're cheap enough and besides are a useful thing to have.
Install the replacement drives. Connect the external drive case (should be firewire). Boot from any installer disk that will boot the hardware being used. Launch Disk Utility from the appropriate Menu. Partition the two new drives. Create a RAID 1 Mirror Set. Make sure you select the 'Automatically rebuild RAID' option. Leave everything else at their defaults. Use Disk Utility to restore the external drive (as the source) to the newly created RAID Set (as the destination). This will take some time as data is written to both drives. When done set the internal RAID set as the Startup Disk. Restart and disconnect the external drive. Remove the drive from the external drive case and place it with the other drive. Put these away and keep them safe for a short while just in case.
Out of curiosity does the hardware/OS support booting from 1.5TB drives? I'm guessing it does otherwise you would not have bought them?
Tony

Similar Messages

  • Install Solaris 11 on a RAID-1 mirror ZFS pool?

    Hi all,
    Sorry if this question has been asked here before.
    I've searched docs.oracle.com about Solaris 11 and didn't see any related info.
    I am installing the new Solaris 11 on my Dell Tower desktop workstation with two 3TB SATA hard drives.
    I am planning to construct one RAID-1 mirror with ZFS just like previous Solaris 10 x86 installation.
    After using lots of installation media of Solaris 11, I didn't find the options to create RAID-1 mirror on ZFS root partition / pool.
    Could someone give me a hint or I must roll back to Solaris 10 again?
    Thanks in advance.

    Yes, it looks like this on a SPARC system:
    ok boot net:dhcp
    Boot device: /pci@780/pci@0/pci@1/network@0:dhcp  File and args:
    1000 Mbps full duplex  Link up
    Timed out waiting for BOOTP/DHCP reply
    <time unavailable> wanboot info: WAN boot messages->console
    <time unavailable> wanboot info: configuring /pci@780/pci@0/pci@1/network@0:dhcp
    1000 Mbps full duplex  Link up
    <time unavailable> wanboot info: Starting DHCP configuration
    <time unavailable> wanboot info: DHCP configuration succeeded
    <time unavailable> wanboot progress: wanbootfs: Read 368 of 368 kB (100%)
    <time unavailable> wanboot info: wanbootfs: Download complete
    Mon Jul  1 14:28:03 wanboot progress: miniroot: Read 249370 of 249370 kB (100%)
    Mon Jul  1 14:28:03 wanboot info: miniroot: Download complete
    SunOS Release 5.11 Version 11.1 64-bit
    Copyright (c) 1983, 2012, Oracle and/or its affiliates. All rights reserved.
    Remounting root read/write
    Welcome to the Oracle Solaris installation menu
            1  Install Oracle Solaris
            2  Install Additional Drivers
            3  Shell
            4  Terminal type (currently xterm)
            5  Reboot

  • What is the best technique to resize a clip and overlay it on a difficult shape, like a broken piece or mirror?

    What is the best technique to resize a clip and overlay it on a difficult shape, like a broken piece or mirror?

    Best would be cutting a matte in Photoshop, or as Mr. Grenadier suggests, using Motion or After Effects - but here is a way to do it staying within FCP - see if this helps:
    http://vimeo.com/34973575
    MtD

  • Raid 1 Mirror Storage Spaces

    Hello,
    I create a Storage Spaces RAID 1 mirroring pool with two identical SATA Hard Disks. If I pull only ONE of the disks and connect it to another computer SATA connector with Windows 8 or Server 2012 installed OS, is the data readable on this computer?
    If I put this disk on a hard disk enclosure (USB enclosure) am I be able to see the files on this disk, because doing mirroring in Windows 7 creates a dynamic disk that can't be connected afterwards on a USB enclosure in order to see the data on it. Has
    this limitation been overcomed from Windows Server 2012.
    Thank you

    Hi, 
    I did that on my test machine. I can read database on the PhysicalDisk when attach it to another Windows Server 2012 computer. 
    Firstly, create a storage pool with two PhysicalDisks on a Windows Server 2012 computer. Then create a mirror virtual disk and new a volume save soma files on the volume.
    After that, remove a PhysicalDisk from the first server and connect it to another Windows Server 2012 computer. System recognize the PhysicalDisk as a storage pool. The storage pool need to be set to read-write then attach virtual disk. In disk management,
    set the virtual disk to online, then we could read the file on the saved on the PhysicalDisk.
    As I did my test on my virtual machine and the PhysicalDisk is a virtual hard disk, you may need to do a test on your machine.
    Regards,
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • Degraded RAID set (mirror)

    I am running a pair of 2 GB external drives in RAID 1  (mirroring) using the OSX Disk Utility.  Recently I noticed that the set shows it's RAID status as Degraded and one of the two drives is indicated as "Missing," which keeps the "rebuild raid set" button grey.  However, I can verify each of them separately and they appear to be okay.  Only one of the drives appears to be partitioned correctly; the "missing" drive simply shows a RAID slice for the entire 2 GB.  
    I would recreate the mirror set, except that I don't have anywhere to store the 1.3 GB still on the good drive, and I believe I cannot create the set again without erasing the contents.  (I back up to the RAID set as well as use it for un-backed up storage, which I think is safe as long as the RAID set is working.)
    Any ideas how to get the "missing drive" to reappear, so the system can rebuild the set?  Or any other ideas to get out of this problem?  Thanks.

    It doesn't change the problem, but obviously I meant TB (not GB)

  • 3rd-party software to make RAID 1 (mirror) on a drive that already has data

    Is there software which lets you simply add a 2nd drive to an already working Mac and make a RAID 1 mirror without waiting for the following:
    - clone the internal drive to an external for backup
    - add the 2nd internal drive
    - erase both internal drives
    - make the RAID 1 set out of both drives
    - clone the data back to the RAID 1 from the external
    This works just fine. It just takes a long time and requires extra external drives to boot from and do the cloning.
    What I'm looking for is a utility that will reduce the process to:
    - clone to external for just-in-case backup
    - add the 2nd internal drive
    - use the utility to mirror the 2nd (new) drive to the pre-existing data on the 1st drive and make a RAID 1 mirror set out of them (without erasing them)
    - there is no step 4. there is no step 4! (ha ha ha)
    in short: to make an OS X RAID 1 without having to erase a drive that already has customer data with the Disk Utility or some other software
    I checked Made4Mac already - none of the listed partitioning tools seem to be able to make a RAID "in place". I'm assuming this is not easy or Disk Utility would already be able to do it.
    It's too bad the Disk Utility can only make a RAID 1 using blank, virgin drives. Maybe they'll fix it in Leopard. Can anyone from Apple comment?
    I know about SoftRAID - but it's $149 per seat. I'm looking for something I can use on customer machines over and over again, without having to sell them a software license - like Partition Magick or DiskWarrior.
    Thanks!
        RAID 1

    IKE-D-
    Why not use the CLI and do it that way? i don't know it AppleScript hooks into the terminal and/or can run terminal commands but that may be worth looking into as well.
    I would think that it would be a good idea to erase all your drives in the RAID at once and start fresh. Why not back up the internal to a pair of RAIDED external FW800 drives, add the second drive in the Mac, make the internal RAID by formatting both drives and then copy the external RAID back to the internal RAID? Oops, I know, now we have a step 4.
    Nobody from Apple ever comments here. We are all users, just like yourself, that just want to help.
    Luck-
    -DaddyPaycheck

  • External RAID 1 (mirrored) advice

    Sorry if this question is in the wrong place.
    I need an external RAID 1 (mirrored) for work.
    We need more shared storage space on our G4 Mac server. I'm a graphic designer not an IT person but the job has fallen to me. Needs to be external RAID drive (with firewire 400, 800 or USB 2) as our internal hard drives that are also mirrored are in use and maxed out. Here are some products I was looking at and each has pros and cons. Need something that is more reliable than fast as well as easy to use. What do you think? Thanks for your insight. Chris
    http://www.lacie.com/us/products/product.htm?pid=10969
    http://www.drobo.com/Products/drobo.html
    http://www.g-technology.com/Products/G-SAFE.cfm
    http://www.newertech.com/products/gmax.php
    http://www.istarusa.com/storage/mini_trayless/v7age220uf.aspx

    More info
    We have 8 macs on ethernet and one g4 server. Looking for something in the 1TB plus range. Easy enough for the non IT person to manage.

  • Can I install Snow Leopard and boot from software RAID 1 (mirror)?

    I have a Mac Pro (quad core 2.66 GHz) on order for my office workstation. Yeah, I know new ones are probably coming out early next year but due to budget and upcoming projects I need one now. What I'd like to do is replace the pre-installed 640GB drive with two 1 TB drives and mirror them. The 640GB drive will be redeployed to another machine in the office. Can I boot from the Snow Leopard install DVD, go to Disk Utility, setup a RAID 1 with the two drives, install Snow Leopard to the mirror and then boot off the mirror set?
    I've searched and found offhand comments to the effect that installing to and booting from a software mirror is OK, but I'd like to know for sure that it's OK. Any experience that you have with such a configuration would be nice to hear.

    Yes. But before you do read the following:
    RAID Basics
    For basic definitions and discussion of what a RAID is and the different types of RAIDs see RAIDs. Additional discussions plus advantages and disadvantages of RAIDs and different RAID arrays see:
    RAID Tutorial;
    RAID Array and Server: Hardware and Service Comparison>.
    Hardware or Software RAID?
    RAID Hardware Vs RAID Software - What is your best option?
    RAID is a method of combining multiple disk drives into a single entity in order to improve the overall performance and reliability of your system. The different options for combining the disks are referred to as RAID levels. There are several different levels of RAID available depending on the needs of your system. One of the options available to you is whether you should use a Hardware RAID solution or a Software RAID solution.
    RAID Hardware is always a disk controller to which you can cable up the disk drives. RAID Software is a set of kernel modules coupled together with management utilities that implement RAID in Software and require no additional hardware.
    Pros and cons
    Software RAID is more flexible than Hardware RAID. Software RAID is also considerably less expensive. On the other hand, a Software RAID system requires more CPU cycles and power to run well than a comparable Hardware RAID System. Also, because Software RAID operates on a partition by partition basis where a number of individual disk partitions are grouped together as opposed to Hardware RAID systems which generally group together entire disk drives, Software RAID tends be slightly more complicated to run. This is because it has more available configurations and options. An added benefit to the slightly more expensive Hardware RAID solution is that many Hardware RAID systems incorporate features that are specialized for optimizing the performance of your system.
    For more detailed information on the differences between Software RAID and Hardware RAID you may want to read: Hardware RAID vs. Software RAID: Which Implementation is Best for my Application?

  • RAID degraded - mirrored striped volumes - how to see if mirroring is working

    I've set up a mirrored raid drive. It keeps showing it as 'degraded', even though I've tested each disk separately and they come up OK.
    What does it mean in this report by 'rebuilding'?
    How do I sort out this 'degraded' status?
    How can I tell if mirroring is working correctly?
    The set up is:
    ===============================================================================
    Name:                 Saturn
    Unique ID:            CF319F64-987B-42FC-8C14-751766B37A49
    Type:                 Mirror
    Status:               Degraded
    Size:                 8.0 TB (8000084869120 Bytes)
    Rebuild:              manual
    Device Node:          disk15
    #  DevNode   UUID                                  Status     Size
    0  -none-    384CF206-BCD5-4804-BDB8-FF1C956EEF64  Online     8000084869120
    1  -none-    F886018B-EEE1-4875-853E-BCD4298683F8  0% (Rebuilding)8000084869120
    ===============================================================================
    Name:                 RAID0.1
    Unique ID:            384CF206-BCD5-4804-BDB8-FF1C956EEF64
    Type:                 Stripe
    Status:               Online
    Size:                 8.0 TB (8000219643904 Bytes)
    Rebuild:              manual
    Device Node:          -
    #  DevNode   UUID                                  Status     Size
    0  disk14s2  78CEBE17-8AFA-4849-A5B2-B73D9906FFE2  Online     2000054910976
    1  disk10s2  5D06DB08-6A3E-4041-A3F8-7E195D5B80DD  Online     2000054910976
    2  disk9s2   E430EC4F-AE2C-4B78-B2CC-04ED88315D3A  Online     2000054910976
    3  disk8s2   46EED2A6-BA53-4D54-8B69-FF5D650B97A0  Online     2000054910976
    ===============================================================================
    Name:                 RAID0.0
    Unique ID:            F886018B-EEE1-4875-853E-BCD4298683F8
    Type:                 Stripe
    Status:               Online
    Size:                 8.0 TB (8000084901888 Bytes)
    Rebuild:              manual
    Device Node:          -
    #  DevNode   UUID                                  Status     Size
    0  disk16s2  0B5223E9-2750-493B-A08E-01DD30E65065  Online     2000021225472
    1  disk5s2   F473AEC5-34A0-444E-AE62-DE755ECCE8A5  Online     2000021225472
    2  disk13s2  BDCBFE64-5771-4F3A-AECA-959B20844CD6  Online     2000021225472
    3  disk11s2  63AF3296-C427-4805-9FB5-B496205F49E8  Online     2000021225472
    ===============================================================================

    Hi,
    As I known, RAID1, or mirroring, is the technique of writing the same data to more than one disk drive. Mirrors are usually used to guard against data loss due to drive failure. Each drive in a mirror contains
    an identical copy of the data. No need to compare.
    If the drive is bootable, You should have got a warning when you booted the machine saying that either drive 0 or drive 1 was corrupt/non-bootable/missing and then be given a choice to boot from the second drive.
    Kate Li
    TechNet Community Support

  • RAID 1 (mirroring), cloning and booting...

    After recently buying a new dual quad-core, I wanted to expand the hard drive space a bit, and enhance the security of a part of the data. Having a 500G disk in bay 1, I planned on putting one additional 500G to create a mirror with the original one, and two more disks simply for space (500G and 1T). I soon encountered some problems..
    As I don't have a RAID card installed, I would have to use Apple's software RAID from within Disk Util; but I soon discovered I would need to initialize both disks that were to be in the RAID (is there a reason for this? I expected I could create a clone drive, so a mirror with one in the RAID already present...). Well, this would mean I have to backup all my data first, then boot from another disk (like the Leopard install disk), create the RAID and replace all my data... So here are my current problems:
    - my Mac Pro won't boot from the Leopard install disk (it's an original Universal disk, so that shouldn't be it); it won't boot from other external disks either, but I believe that's caused by the partition tables being in APM, not GUID, as they were created on a G4...
    - I need to make a complete clone of the boot disk, but all I can do with Disk Util (or CCC) is make a clone of the Mac partition (or loose partitions at all). I have a BootCamp partition as well, which I would like to clone too, so what I'd want is a possibility to clone the whole drive, instead of independent partitions. It seems there is a terminal command able to do something like that, but I'm not familiar with using it.
    - I read about the software RAID solutions causing problems in Leopard (corruption of RAID headers). Does anyone know more about this, and whether it has been solved?
    I'm sorry for putting three things together, but I thought it might make it easier to understand if the connection between the problems was clear. Any help would be greatly appreciated.
    Piotr / iBear

    Hmm.. This does explain a few things, especially the part about having X.5.2 as a minimum.. The slight problem with the the disk that was packaged with the machine is that my dad (for whom I'm setting it up) has been "cleaning up" his disks - I've had a hard time finding the Leopard disk for that matter... - and is now on a trip for the next two weeks. I'm now configuring a new external install - entirely fresh and updated to X.5.4 - to try booting from that.
    I thought both AppleRAID and SoftRAID had that problem, that's what I understood from the post you left in another topic, but I guess I don't have to worry about that anymore. happy
    The purchases have actually already been made, and as there were no 640G disks available, I had taken the 500G's. So, the machine is already set up with 3x500G (2xWD, 1xSeagate) and 1x1T (Seagate as well). As the original system is on one of the WD's, I wanted to create the RAID with two identical disks; will it make any difference if they are not? (I know it will work, but would it have any impact?)
    And just a last small question: as I noticed before, CCC doesn't do entire drives. Should I partition the RAID drive like the original and then use CCC to copy the BootCamp partition? (found SD after a small search) > I think the same questions go for that as well...
    Many thanks for the very fast reply!

  • Tryng to format Raid 1 (Mirror) array on Promise controller

    Ok, I installed the two brand-new, indentical hard drives, booted up the computer, the promise utility noticed that I had two drives plugged in with the promise controller set to RAID mode, so it ran the thing and I set the array to security (aka: Raid 1) so then it does it, and says I can reboot. Now, the manual said that the only step I have to complete now to finish it is to run FDISk or whatever to format the "drive" (Since the array is treated as one drive). I do have to do this, but hwo do I do it? I run Win 2000 Pro if that helps at all. I am trying to make it an NTFS filesystem however, so would FDISk even work? I thought FDISk only makes FAT32 file systems... Anyway, what do I do to finish setting up my RAID 1 array and get to finally use it?
    Doggonit

    I use Win 2000 Pro and there is no Maintenance or Performance in the Control Panel. I tried reinstalling the drivers and even uninstalling the drive as it showed up in the Device Manager under drisk drives. It simply came back the same way as before, as some 1x2 Promise RAID1 SCSI drive that was functional etc, but I dont know hot to format it and I can't see it in Windows Explorer, or in the BIOS, altough during bootup it shows the Array every time and if I check out the Promise array manager (Ctrl+F) I can see it and it is functional and all that.
    Ok, this is it:
    In the device manager (Control Panel->System->Hardware->Device Manager) under the disk drives menu I see my working 80Gb drive that the OS is on, and has its "Location" as: " Location 0 (0) " and then there is the:
    Promise 1X2 Mirror/RAID1 SCSI Disk Drive Device
    In the properties of this it says: Bus Number 0, Target ID 0, LUN 0
    Also, for the Write cache, the box is unchecked, as in not enabled, and it is grayed over, so I can't even change it. I guess this is beacuse the drive is not yet formatted and cannot be written to yet, right?
    Is there a conflict between the 80GB drive and the RAID1 Array on the BIOS level that I should fix somehow? Is the Location of the 80GB one be 1 or do those numbers for the array have to be 1 ?
    I think I really wont be able to get this to work without some major help.  Now I see why IDE drives still rule. They are more accesible from the BIOS.
    Doggonit

  • Recover server from Raid 1 mirror

    I have a Sunfire V210 with 2 hard drives using Raid 1 to mirror the drives. After a power outage the primary hard drive has become corrupted - I have booted from cdrom -s and tried to do an fsck on the root corrupted partition but it has a bad superblock and none of the alternatives will work so I do not know if I can recover the drive.
    What I have been able to do though is mount the second mirrored hard drive from the cdrom and it all looks to be in tact. Is there anyway I can use this hard drive to restore the corrupted drive or make this drive the primary drive, boot from it, swap the corrupted drive and make it the mirrored drive or is there a better solution?
    Thanks.

    At the ok prompt try: 'boot disk1' (you've probably replaced the disk by this
    but it would be good keep in mind for the next go-round)
    Dean

  • Using RAID 1 mirror for backups

    I am considering setting up a RAID 1 volume (1 primary and 1 secondary disk) and using the secondary mirror as the source for archive to a file-server. This should give me a perfect snapshot in time of my volume and the read access from the volume would not affect system performance too much. The strategy I have in mind is to remove the mirror from the RAID 1 volume, mount it as a normal volume and make a backup from it (using EMC Retrospect) to a file server over our network. Once the backup is done, I would unmount the mirror and reconnect it to the primary disk to recreate the RAID volume.
    My questions are:
    1) Is this possible with OS X's built-in RAID functionality?
    2) Am I better off with using SoftRAID 3?
    3) Will the rebuild of the RAID volume be as if it was from scratch (that is, would it take too long for a 150GB volume)?
    4) If I have two 150GB disks (SATA), can I make the entire disk one RAID volume and still boot from it?
    5) If the answer to Q4 is "no", with OS X's built-in RAID, can I make a RAID volume out of partitions from two disks? In other words, am I forced to use whole disks for a RAID members in OS X?
    Your help in this would be very much appreciated.
    Mac Pro   Mac OS X (10.4.7)  

    Using mirrored RAID is NOT my sole backup method. It is part of it. The idea is to backup a secondary mirror to an tape or disk based backup system on our file server using EMC Retrospect. This would provide recovery from deleted or modified files.
    The need to unmount a mirror from backup comes from my desire to have perfect snaphots-in-time for backup. Backing up a live filesystem can lead to inconsistent states in the backup. For example, backing up 50G over a network can take several hours. If, for example, you are writing an article that contists of several files, and you had a draft of file #1 that was copied to the backup. A little later, while editing file #2, you decided to move some text from it to file #1. After moving this, file #2 is backed up, with the moved text removed from it. The end-result in the backup is that the text is in neither file #1 or file #2.
    Backing up live file-systems has this inherent danger. One way of avoiding it is to create an instant snapshot of the entire file system to a second drive and backup from that drive. The mirrored secondary drive in the RAID system would have this snapshot, continually updated. It would have to be disconneted from the RAID set before the backup from it is started in order to preserve the snapshot's consistency.

  • Can I create RAID 1 mirror without ERASE ing drive?

    Hi!
    Simple enough, I have a nearly new 1TB (call it HD2) and decided to add an identical one (call it HD3) and create a mirrored RAID in the MacPro (everything is backed up externally).
    Drive HD2 is half full with client photographs and stuff, and I would like to drag it into a RAID set with the new drive HD3.
    When I do that I'm prompted to erase the drive. Is there a way to create a RAID without the erase?
    By the way, would using a RAID0 be a better option perhaps? I really like the ability to just unplug a duff drive and swap for a good blank one and let the computer do its stuff. That's already come in handy once this year with a failed ext drive!
    Cheers

    Good backups (2 per volume) are more useful.
    Creating a RAID destroys the data on the drives.
    A mirror for 24/7 uptime and where live recording is essential. In which case, 3, not 2, drives in a mirror are your best bet, and using $149 program SoftRAID.

  • Setting up RAID-1 mirror as aliased boot device on V240

    Hi Guys,
    I've successfully mirrored 4 slices from the original disk
    to the second one in our v240, the raid as such works,
    and is consistent. I then did the following:
    <div class="pre"><pre>installboot /usr/platform/`uname -i`/lib/fs/ufs/bootblk /dev/rdsk/c1t1d0s0init 0devalias disk_mirror /pci@1c,600000/scsi@2/sd@1,0:aboot disk_mirror</pre></div>
    But on reboot the machine complained that it couldn't
    find the kernel ...
    What did I do wrong?
    Cheers,
    Andrej

    <table border="0" align="center" width="90%" cellpadding="3" cellspacing="1"><tr><td class="SmallText"><b>m-lennon wrote on Fri, 02 December 2005 07:45</b></td></tr><tr><td class="quote">
    Very amusing comment Michael!
    </td></tr></table>
    Actually I think he just didn't believe me when I said
    that I have SUCCESSFULLY mirrored 4 slices (/, /var swap
    and /adv). Yes, I did use metastat to check on the
    process, and yes, after a couple of hours even the
    largest slice (/adv) was successfully mirrored.
    <table border="0" align="center" width="90%" cellpadding="3" cellspacing="1"><tr><td class="SmallText"><b>m-lennon wrote on Fri, 02 December 2005 07:45</b></td></tr><tr><td class="quote">
    One of the things that can be confusing when moving from Linux on PC to Solaris on SPARC systems is the obp, far more robust than BIOS! I have found that this puts Linux administrators off using SPARC systems, but these systems aren't that complicated if you understand how to use them ( entry level systems at least ). A good place to start is http://docs.sun.com/ and BigAdmin. As Michael suggested the man pages are an excellent source for quick information. Any time I work on a Linux system I use the man pages all the time because the GNU commands can be different. In fact during exams like the RHCE you are allowed to use the man pages to help you answer the problems/questions. Can you tell us if you have followed a procedure or guide when you set up your root mirror?
    </td></tr></table>
    I followed the general outline as it was given to me
    in the course SA-299 ...
    <table border="0" align="center" width="90%" cellpadding="3" cellspacing="1"><tr><td class="SmallText"><b>m-lennon wrote on Fri, 02 December 2005 07:45</b></td></tr><tr><td class="quote">
    Have you searched the forum for any references, I have posted to a thread outlining the steps to take to configure a root mirror some time ago:
    http://supportforum.sun.com/hardware/index.php?t=msg&got o=17942&rid=3131&SQ=c7d34a55da48e884a4ea26ddaf162731
    I think it is difficult to try and provide this information through the forum, as you can see in this thread it was far from straight forward! If you want to outline more about your current configuration, I can try to give you some pointers.
    </td></tr></table>
    The mirroring wasn't the problem. I suppose I didn't quite
    understand Michaels question; I assumed that he wants me
    to check if the files are present on the mirror, which is what
    I have no clue how to do; as in looking at it as if it were a
    stand-alone HDD.
    However: The mirroring wasn't the problem, the attempt to
    boot (to verify that I'll have a working system if disk 1 dies)
    of the secondary side of the mirror was ...
    Cheers,
    Andrej