Broker switchover from single ins to 2nodesRAC problem
hello,
i installed and configured 11Gr2 2 node rac primary. and single instance grid + single instance database 11gr2 standby side.
but there is a problem. primary database name is the same for all rac nodes of me (kkrac). there are 2 instances; kkrac1 and kkrac2.
when i tried to switchover to 'kkrac' back from standby side(kkguard).. broker is looking for dr1kkrac.dat and dr2kkrac.dat files. but they dont exist. and they are wrong file names. it should be instance names; like dr1kkrac1.dat dr2kkrac2.dat.
and so i copied and renamed .dat files from guard to primary nodes (node1, node2); but it didnt work:)
DRCX: DRC Unique ID mismatch...
question)
i want to swichover "from single instance" db TO "2 nodes RAC db" with broker;
if i use the same db name for rac nodes (kkrac), it fails because, brooker dr1kkrac.dat dr2kkrac.dat files dont exist.
how can i do it correctly?
best regards;
CREATE CONFIGURATION 'KKGUARDCONF' AS PRIMARY DATABASE IS 'kkrac' CONNECT IDENTIFIER IS 'kkrac';
ADD DATABASE 'kkguard' AS CONNECT IDENTIFIER IS 'kkguard';
DGMGRL> show configuration
Configuration - KKGUARDCONF
Protection Mode: MaxPerformance
Databases:
kkrac - Primary database
kkguard - Physical standby database
Fast-Start Failover: DISABLED
Configuration Status:
SUCCESS
DGMGRL> switchover to 'kkguard'
Performing switchover NOW, please wait...
New primary database "kkguard" is opening...
Operation requires shutdown of instance "kkrac1" on database "kkrac"
Shutting down instance "kkrac1"...
ORA-01031: insufficient privileges
Warning: You are no longer connected to ORACLE.
Please complete the following steps to finish switchover:
shut down instance "kkrac1" of database "kkrac"
start up instance "kkrac1" of database "kkrac"
DGMGRL> show configuration
Error:
ORA-03114: not connected to ORACLE
Configuration details cannot be determined by DGMGRL
DGMGRL> connect /
Connected.
DGMGRL> show configuration
Configuration - KKGUARDCONF
Protection Mode: MaxPerformance
Databases:
kkguard - Primary database
kkrac - Physical standby database
Fast-Start Failover: DISABLED
Configuration Status:
SUCCESS
Edited by: donniedarko on 23-Dec-2010 07:01
It is lool like the new standby database is started from old home:
alert log:
Starting up:
Oracle Database 11g Enterprise Edition Release 11.2.0.1.0 - 64bit Production
With the Partitioning, OLAP, Data Mining and Real Application Testing options.
Using parameter settings in server-side spfile /u01/app/oracle/product/11.2.0/db_1/dbs/spfileDB1.ora
System parameters with non-default values:
My old home (11.2.0.1) u01/app/oracle/product/11.2.0/db_1
My new home (11.2.0.2) u01/app/oracle/product/11.2.0/db_2
previous start this database:
alert log:
Starting up:
Oracle Database 11g Enterprise Edition Release 11.2.0.2.0 - 64bit Production
With the Partitioning, OLAP, Data Mining and Real Application Testing options.
Using parameter settings in server-side spfile /u01/app/oracle/product/11.2.0/db_2/dbs/spfileDB1.ora
System parameters with non-default values:
Why database is starting from old home?
I Changed directories in .bash_profile oracle OS user.
Similar Messages
-
Interactive report: Can I exclude a particular column from single row view?
Hi -- I posted on this yesterday (Possible to exclude interactive report column from single row display?
a bit anxious for suggestions, I guess!
I've added a column with edit-link functionality to my interactive report query (that is, the link
is not attached to the database data... it's an additional column and shows an icon). It's also
in addition to the default single row view link. (We need both.)
Unfortunately, the Edit link column shows up in the single row view. I've pared it down as much
as I can: the label is empty, and the null value shows as "-". But an extra row with "-" is pretty
ugly. Is there a way to always, completely exclude this column from the single row view?
I know I could put the edit link on a data column, but:
1) I want the link to always be to the left of the data (and the user can re-order columns)
2) when the user doesn't have edit privileges, the link will need to be disabled or just not
be displayed, and I think that would be a problem if the link were on the data. (true?)
Thanks,
CarolPlease disregard this thread, and the one it refers back to. I see a flaw in the design of what I was attempting to do! Creating the link for Editing as a column means the user could inadvertently not display it, or move it, or... any number of problematic scenarios.
Thanks,
Carol -
IMac G5 won't boot in normal and safe mode, but will from single-user mode
Hello everyone,
I'm quite new here, so I try to do my best if you have a question.
Yesterday, someone nearby me had a iMac G5 (Powermac8,1), and he sayd, that the computer sometimes will boot, sometimes not.
I did test it, I thought it was running fine, but when I played some music in iTunes, it was stuck on 9 seconds, and crashed (with a kernel panic). The guy also sayd, that there was nothing important on the computer, so a clean install was fine.
Now, the problem is, that it will not boot in normal mode (without anything pressed on boot), also it won't in safe mode (shift-boot), but it will, when I enter single-user mode, mount the hard drive and exit from single-user mode so it will go futher on booting. Sometimes it will not, and immediately gives you a kernel panic in single-user mode, but it will 90 percent of the time.
Then you've got another problem: when it's running in the normal desktop from single-user mode, it'll be stuck after some time again. If I look into the Kernel Panic file created, most times it's because of Spotlight indexing, so I disabled that.
He also gave me the disks (Apple Hardware Test and Extra Applications, and iMac G5 Mac OS X Install Disks 1-3) that came with the Mac. He sayd that I could use them, but I think he didn't test out the SuperDrive, because when I insert a disk, it will try to read, but it will make 2 same sounds, and quits after 10 tries, when it will spit the cd out. Also normal (audio) disks.
Also, I must hurry with the commands for mounting and exiting in single-user mode, or it will just not boot.
In all cases, after 30-45 seconds from pressing the power button, the fan will start blowing at full speed, and it will stop after the exit command in Single-user mode. That's weird.
I can't do anything with the SuperDrive, I can't normally boot in Mac OS X except for Single-user mode (but I don't think he would like to do that every time the computer boots up), and I have very limited time when Mac OS X arrived on the desktop.
When booting in Verbose mode, it will be stuck on this:
AppleSMU::PMU vers = 0x000d004c, SPU vers = 0x15, SDB vers = 0x01,
(and sometimes ends with a kernel crash by fsck_hfs)
Things I've tried (without any success):
- /sbin/fsck -fy (in single-user mode)
- Disabling Spotlight and mds
If you want some more information, feel free to ask!
Greetings
-MrYoranimo
PS: My main language is Dutch, so my English can be bad at some points.Thank you for your support! This reply is a little bit late, because I was to the camping this weekend.
The only thing I sure do know, is that the iMac has a bad SuperDrive. That's one problem, but I don't really wanna use it, and you fix everything by Single-user mode and when I get to the desktop to test things and change stuff in the Preference Panes.
What also came to my mind was that there also is a problem with the videocard (driver), because sometimes when I boot into Single-user mode, I can see some white pixels which aren't supposed to be there. And when booting from SUM you can see that some of the colors are different and there are weird patterns on the screen.
I also tried to setup a NetBoot server on this computer (MacBook Mid 2010) with just Lion 10.7.4 on it, but I'm not that expert and I didn't really find the good posts on the Internet, although I tried it with the Server applications and both Server applications and DeployStudio. But I didn't succeed.
I don't really like buying a new FireWire hard disk or external FireWire dvd reader/writer, except if it has USB support, because my MacBook doesn't support FireWire, and I really wanna make use of it then.
If I know more or have fixed it, I will surely post again here with what I did to fix it (if no one else has posted here already ). -
Changing controlling area from single company code to cross company code
Hi,
Due to my client requirement, in the middle of the year, we need to change the controlling area from being same as company code to cross company code controlling area. Although the currency is same. We are going to create a new company code. Is the changing controlling area settings possible to do? what are the precautions and changes need to be taken?
One more question, we need to change the company code when the new company code is created in the system in Cost Center Masters in the middle of the year. Is this possible after changing controlling area from single company code to cross company code. Right now company code is not appearing in the cost center master.
Thanks & Regards,
SaidaraoHi,
If both companies having transaction data its not possible,Normally before defining Organisational Strucutre only we have to deside both companies is assigning same controlling are or have to maitain separately for this we have to compare the Fiscal year,Operating chart of accounts ,if both having same then we will assign both the company codes to one controlling area if these two companies having different currencies also its not a problem.When we creating Controlling Area we have to choose option of controlling area as same company code (if one company code one controlling Area) for example if you assigning two companies then we have to use cross company code cost accounting.If u need any further information let me know.
Regards,
Satya -
RE: Accessing multiple Env from single Client-PC
Look in the "System Management Guide" under connected environments page
72. This will allow services in your primary environment to find
services in your connected environment. However, there is a bug
reported on this feature which is fixed in 2F4 for the HP and H1 for all
other servers. The following is from Forte:
The connected environments bug that was fixed in 2F4 is #24282. The
problem
was in the nodemgr/name server source code and caused the following to
occur:
Service1 is in connected envs A and B.
Client has env A as primary, B as secondary.
Envmgr A dies before the client has ever made a call to Service1.
Afer env A is gone, client makes a call to Service1 which causes Envmgr
B to
seg fault.
You should upgrade your node manager/env manager nodes to 2F4. The 2F2
development and runtime clients are fully compatible with 2F4 servers.
Kal Inman
Andersen Windows
From: Inho Choi[SMTP:[email protected]]
Sent: Monday, April 21, 1997 2:04 AM
To: [email protected]
Subject: Accessing multiple Env from single Client-PC
Hi, All!
Is there anybody has any idea to access multiple environments from
single client-PC? I have to have multiple environments because each
environment resides geographically remote node and network bandwidth,
reliability are not good enough to include all the systems into single
environment.
Using Control Panel for doing this is not easy for those who are not
familiar with Windows. The end-user tend to use just single application
to access all necessary services.
I could consider two option to doing this:
1. Make some DOS batch command file to switch different environment
like, copying back/forward between environment repositories and
set up forte.ini for changing FORTE_NS_ADDRESS. After then, invoke
proper client partition(ftexec).
2. Duplicate necessary services among each environment.
But, these two options have many drawbacks in terms of system
management(option 1), performance(option 2) and others.
Has anybody good idea to implement this? Any suggestion would be
appreciated.
Inho Choi, Daou Tech., Inc.
email: [email protected]
phone: +82-2-3450-4696Look in the "System Management Guide" under connected environments page
72. This will allow services in your primary environment to find
services in your connected environment. However, there is a bug
reported on this feature which is fixed in 2F4 for the HP and H1 for all
other servers. The following is from Forte:
The connected environments bug that was fixed in 2F4 is #24282. The
problem
was in the nodemgr/name server source code and caused the following to
occur:
Service1 is in connected envs A and B.
Client has env A as primary, B as secondary.
Envmgr A dies before the client has ever made a call to Service1.
Afer env A is gone, client makes a call to Service1 which causes Envmgr
B to
seg fault.
You should upgrade your node manager/env manager nodes to 2F4. The 2F2
development and runtime clients are fully compatible with 2F4 servers.
Kal Inman
Andersen Windows
From: Inho Choi[SMTP:[email protected]]
Sent: Monday, April 21, 1997 2:04 AM
To: [email protected]
Subject: Accessing multiple Env from single Client-PC
Hi, All!
Is there anybody has any idea to access multiple environments from
single client-PC? I have to have multiple environments because each
environment resides geographically remote node and network bandwidth,
reliability are not good enough to include all the systems into single
environment.
Using Control Panel for doing this is not easy for those who are not
familiar with Windows. The end-user tend to use just single application
to access all necessary services.
I could consider two option to doing this:
1. Make some DOS batch command file to switch different environment
like, copying back/forward between environment repositories and
set up forte.ini for changing FORTE_NS_ADDRESS. After then, invoke
proper client partition(ftexec).
2. Duplicate necessary services among each environment.
But, these two options have many drawbacks in terms of system
management(option 1), performance(option 2) and others.
Has anybody good idea to implement this? Any suggestion would be
appreciated.
Inho Choi, Daou Tech., Inc.
email: [email protected]
phone: +82-2-3450-4696 -
How to migrate DB from single node 10gR2 to RAC 11gR2 on diff platform?
How to migrate DB from single node 10gR2 to RAC 11gR2 on different platform with possible minimum downtime? We have a situation of upgrade/migrate oracle 10gR2 single instance DB to 2-node RAC 11gR. The source OS is Solaris 10 on SPARC and the target OS is Linux (the target servers could be changed to Solaris 11 x86 if needed). What is the best solution on that?
Thanks,Technically, can do the following for upgrading and migration?
1. Create 11gR2 oracle home on the same server and upgrade the database from 10gR2 to 11gR2 by running conversion (2 hour down time?)
2. Set up Heterogeneous Primary and Physical Standbys by RMAN. The standby is the RAC with ASM. No need down time. (from Solaris Space to Linux - this may be a problem)
3. At the cutoff time, activate the standby DB from the RAC ASM.
If feasible, do we have some detail guild line for each step? -
Converting from single episodes to seasons
What happened to episodes already purchased when you convert from single downloads to buy a whole season? Dop you get credits for the episodes you purchased before iTunes offeres up the series as a single purchase?
It's not a true conversion problem that you have but more a space problem. Tables columns are created by default with the init. parameter NLS_LENGTH_SEMANTICS character semantics:
If NLS_LENGTH_SEMANTICS = BYTE
then 1 character = 1 byte whatever the db character set
If NLS_LENGTH_SEMANTICS = CHAR
then 1 character = 1 character size for the db character set.
If this parameter is changed it is only taken into account for newly created tables or columns: existing columns are not changed.
See http://download-uk.oracle.com/docs/cd/B10501_01/server.920/a96529/ch2.htm#104327
The only solution I see is to enlarge your VARCHAR2 columns before running the import...
Message was edited by:
Pierre Forstmann -
On Excel 2013 (64 bit), I can't use the Analysis ToolPack add-ins without a problem and plot the residuals. It went crash.
Hi,
In regarding of the issue, please provide us more information to assist you better.
Do you mind telling us the Excel version number? Like 15.0.XXXX.1000
Would you like to collect the Event Log and App Crash dump file to do further troubleshooting?
As far as I know, if Excel crashes when using Analysis ToolPack add-ins, it usually causes by the >>Faulting module name: mso.dll<<, Please try the following method and check if it is helpful:
1.Copy/paste the Mso.dll from another PC.
2.Click "Start" and "Computer."
3.Double-click "C: Drive," "Windows" and "System32." The System32 folder opens.
4.Drag the Mso.dll file on your desktop into the System32 folder.
5.Click "Start," type "cmd" into the search field and press "Enter" to open the Command Prompt.
6.Type "regsvr32 mso.dll" (without the quotation marks) into the Command Prompt and press "Enter."
7.Close the Command Prompt and restart your computer.
Then, if the Faulting module name is not MSO.Dll, you also can upload(Or send to us via email
[email protected]) the Event Log/App Crash dump file. We'd like to do further troubleshooting.
Regards,
George Zhao
TechNet Community Support
It's recommended to download and install
Configuration Analyzer Tool (OffCAT), which is developed by Microsoft Support teams. Once the tool is installed, you can run it at any time to scan for hundreds of known issues in Office
programs. -
Partial Delivery to Several Ship to from Single SO
Dear all,
We have a case to create partial Delivery to several ship to from single Sales Order ,
case like this :
Sales Order #12345
Sold to : ABC, Ship to : ABC (default)
Item XYZ, Quantity 50 Pcs
Sales Order Date : 3/1/09
When creating SO, we do not know the ship to, so we make it default to ABC.
Ship to known until the truck/Customer come to take their goods.
let say 4 Partial Delivery Order created from Sales Order #12345
Delivery Order Date : 3/2/09
Delivery Order #1001
Ship to : ABC
Item XYZ, Quantity 20 Pcs
Delivery Order Date : 3/3/09
Delivery Order #1002
Ship to : DEF
Item XYZ, Quantity 15 Pcs
Delivery Order Date : 3/4/09
Delivery Order #1003
Ship to : GHI
Item XYZ, Quantity 10 Pcs
Delivery Order Date : 3/5/09
Delivery Order #1004
Ship to : ABC
Item XYZ, Quantity 5 Pcs
The problem is Ship to in TCODE VL01N disable to edit/choose ship to, it always point to "ABC" (from Sales Order).
Anyone know how to make ship to in TCODE VL01N enable for input /choose ?
or any other solution for this case ?
Thanks for response.
Iwan BudimanDear Budiman,
If you want do the partial deliveries to different ship to parties from single sales order you need to maintain seperate line item for each partial delivery and you need to assign 4 different ship to parties for each line item at Item data-->partners tab .
In your case you want to 4 partial deliveries so you need enter material XYZ as 4 items in the sales order.
Item 10 >XYZ>20 pc
Item 20 >XYZ>15 pc
Item 30 >XYZ>10 pc
Item 40 >XYZ> 5 pc
Now you go to Item data-->Partners tab of each item them maintain the 4 different ship to parties to each item..
Item 10 >20 pc>Ship to ABC
Item 20 >15 pc>Ship to DEF
Item 30 >10 pc>Ship to GHI
Item 40 >5 pc> Ship to ABC
Complete the sales order with all data now you can create 4 partial deliveries for 4 line items with diferent ship to party.
Note:- Make sure that all ship to parties are have master data.
I hope this will help you,
Regards,
Murali. -
Video graphics adapter broke apart from motherboard
i have a compaq sr 5421F , my video graphics adapter broke apart from the motherboard, how do i replace it, buy a new motherboard or can i just plug a graphics adapter somewhere else on the same motherboard?
You would need a PCIEx16 v2 graphic card. That also means a new power (PSU) supply, as your present system has a meager 250W PSU. How are you using this unit? Just the onboard games, internet.
I am a volunteer. I am not an HP employee.
To say THANK YOU, press the "thumbs up symbol" to render a KUDO. Please click Accept as Solution, if your problem is solved. You can render both Solution and KUDO.
The Law of Effect states that positive reinforcement increases the probability of a behavior being repeated. (B.F.Skinner). You toss me KUDO and/or Solution, and I perform better.
(2) HP DV7t i7 3160QM 2.3Ghz 8GB
HP m9200t E8400,Win7 Pro 32 bit. 4GB RAM, ASUS 550Ti 2GB, Rosewill 630W. 1T HD SATA 3Gb/s
Custom Asus P8P67, I7-2600k, 16GB RAM, WIN7 Pro 64bit, EVGA GTX660 2GB, 750W OCZ, 1T HD SATA 6Gb/s
Custom Asus P8Z77, I7-3770k, 16GB RAM, WIN7 Pro 64bit, EVGA GTX670 2GB, 750W OCZ, 1T HD SATA 6Gb/s
Both Customs use Rosewill Blackhawk case.
Printer -- HP OfficeJet Pro 8600 Plus -
Single record insert performance problems
Hi,
we have on production environment a Java based application that makes aprox 40.000 single record Inserts per hour into a table.
We ha traced the performance of this Insert and the medium time is 3ms, that is ok. Our Java architecture is based in Websphere Application Server and we access to Oracle 10g through a WAS datasource.
But we have detected that 3 or 4 times a day, during aprox 30 seconds, the Java service is not able to make any insertion in that table. And suddenly it makes all the "queued inserts" in only 1 second. That "pause" in the insertion cause problems of navigation because is the top layer there is a web application.
We are sure that is not a problem with the WAS or the Java code. We are sure that is a problem with the Oracle configuration, or some tunning action for this kind of applications that we don´t know. We first thought it could be a problem with a sequence field in the table. Also, a problem when occurs the change of the redo log. But we've checked it with our DBA and this is not the problem.
Has anybody any idea of what could be the origin of this extrange behaviour?
Thanks a lot in advance.
Jose.There are a couple of things you'd need to look at to diagnose this - As Joe says it's not really a JDBC issue from what we know.
I've seen issues with Oracle's automatic SGA resizing causing sporadic latency in OLTP systems. Another suspect would be log file sync wait events, which are associated with commits. Don't discount the impact of well meaning people using tools like TOAD to query the DB - they can sometimes cause more harm than good.
Right now I'd suggest you run AWR at 10 minute intervals and compare reports from when you had your problem with a time when you didn't. -
Upgrade from Single Edition to Professional
We have just upgraded to Professional from Single Edition. When we submit our folio (for iPhone) to the App Builder we are asked for a Title ID and password. We put our Adobe ID and password and only got: “Bundle account has no publication“
This is now the standard message we get, even if we are only updating older Single edition apps!!
We need an answer to this problem a.s.a.p
... Help please.
thank you,
YngviYes, you need a different Adobe ID for each app you create. That's how you determine which folios you publish appear in which apps. You might want to read the getting started guide for pro publishers.
http://www.adobe.com/content/dam/Adobe/en/products/digital-publishing-suite-family/pdfs/dp s-getting-started-guide.pdf -
Have any one attended Peoplesoft Integration Broker training from Oracle?
Hi,
Have any one attended Peoplesoft Integration Broker training from Oracle?
If yes please contact me on my mail id [email protected] i have some queries.
Thanks in Advance,
AmitYes, I could ping both machines from each other.
Here is the host file contents from Windows 7:
127.0.0.1 localhost
::1 localhost
127.0.0.1 activate.adobe.com
192.168.1.106 RAJ-PC
Here is from Window 2003 server:
127.0.0.1 localhost
192.168.1.100 saroja
Both nodes are listed under PeopleTools>Security Objects> Single Signon
Both nodes are secured with userid/pwd on Node page.
One of my machine had fire wall on, so I swtiched the fire wall off. Now machine A can ping both nodes but machine B can ping only local node. Pinging remote node displays "User name not defined in database".
Raj
Edited by: Raj on Jun 13, 2011 11:37 PM -
Hi, since installing mountain lion on my macbook, it wont download pdf files from internet sites, the same problem does not exist on my mac mini, i am using firefox on both macs, please help!
Back up all data.
Quit Safari. In the Finder, select Go ▹ Go to Folder... from the menu bar, or press the key combination shift-command-G. Copy the line of text below into the box that opens, and press return:
/Library/Internet Plug-ins
From the folder that opens, remove any items that have the letters “PDF” in the name. You may be prompted for your login password. Then launch Safari and test.
If you still have the issue, repeat with this line:
~/Library/Internet Plug-ins
If you don’t like the results of this procedure, restore the items from the backup you made before you started. Relaunch Safari again. -
Could anyone help me on switchover from Oem
Hello All,
I have been trying to explore if I can switchover my Primary to standby using OEM 12c. We are using OEM 12c for monitoring the databases. But standby dbs are seen as down/unkown state due to normal setup. I tried with giving the credentials of sys under "Monitoring Configuration" but din't help.
My intention is to see the proper state of standby rather than unkown state/ Down and perform a switchover from oem.
I tried finding any document for it but din't find my search lucky enough to get helped on this.
So could you please help me in this??
Regards,
J_DBAplease see attachment: I think there is some problem while uploading...
<?xml version="1.0" encoding="utf-8"?>
<mx:Application xmlns:mx="http://www.adobe.com/2006/mxml" layout="absolute">
<mx:TextInput x="185" y="50" id="txtInp1" width="79"/>
<mx:TextInput x="185" y="115" id="txtInp2" width="79"/>
<mx:TextInput x="349" y="85" id="txtInp3"/>
<mx:VRule x="295" y="59" width="1" height="71"/>
<mx:VRule x="295" y="59" width="1" height="71" strokeColor="#191B1B"/>
<mx:HRule x="264" y="59" strokeColor="#101111" width="32" height="2"/>
<mx:HRule x="264" y="59" strokeColor="#101111" width="32" height="2"/>
<mx:HRule x="295" y="94" strokeColor="#101111" width="55" height="2"/>
<mx:HRule x="264" y="127" strokeColor="#101111" width="32" height="3"/>
<mx:Button label="Concat" click="txtInp3.text = (txtInp1.text + txtInp2.text);" x="185" y="162"/>
<mx:Label x="125" y="52" text="Label 1"/>
<mx:Label x="125" y="117" text="Label 2"/>
</mx:Application>
Maybe you are looking for
-
Why is the community filtering/search so broken
Why is filtering/search in the Visual Studio community so broken? If I try to limit the scope of my question ("task board") to one forum ("Visual Studio Online") - it seems to be impossible to do: If I enter "task board" in the right hand search
-
The right headset for mac and skype
hello there are problems with line in on g4 macs which are well known so here is the answer buy a plantronics 45 headset BUT NOT FROM APPLE BECAUSE THEY CHARGE 79 POUNDS WHEN EBAY OR AMAZON CHARGE ONLY 29 POUNDS IT WORKS GREAT PLUS YOU GET 120 MINS F
-
Error in evaluating correlation query
Hi, I am using 10.1.3.3.1 MLR#14 Patch (upgrade from 10.1.3.1). I have created a process where in I've created correlation sets. Basically, I am placing an Order XML on JMS queue (invoking JMS adapter) and the next activity is 'Receive' activity whic
-
Hi All, I've upgraded a 3750 integrated controller and a 4402 to 5.0.148.0 (s/w and bootloader image) but the sh sysinfo ouput still reports the previous bootloader version: Product Version........... 5.0.148.0 RTOS Version..... Linux-2.6.10_mvl401 B
-
for our project, our teacher assigned us to make a java rpg game. this is not a very advanced game, the map is only stationary, and you know, the hero moves around it, and stuff bottom line is: i do not know how to begin. could you please give me som