Build usuccessful in LV8.0.1 and Report generation toolkit 1.1.1

I am trying to build an executable. I had included _wordsub.llb and _exclsub.llb as dynamic VIs.
This message is all what I get and no executable is created.
The file already exists in the destination.
C:\Program Files\National Instruments\LabVIEW 8.0\vi.lib\addons\_office\_wordsub.llb
Any ideas?
Scientia est potentia!

This appears to be a duplicate post.  Check out my response to the other thread here.
-D
Darren Nattinger, CLA
LabVIEW Artisan and Nugget Penman

Similar Messages

  • Error 10 when building an application in LV8 and Report generation toolkit 1.1.1

    I am trying to build an application using LV8.0.1 and Report generation toolkit 1.1.1 and i get this error.
    Error 10 occurred at ABAPI Dist Copy Non-VI Files.vi -> ABAPI Dist Build LLB Image.vi -> ABAPI Copy Files and Apply Settings.vi -> EBEP_Invoke_Build_Engine.vi -> EBUIP_Build_Invoke.vi -> EBUIP_Build_Invoke.vi.ProxyCaller
    Any ideas?
    Scientia est potentia!

    Did you attempt to add the _wordsub.llb and _excelsub.llb files to the application as support files?  I believe in LabVIEW 8.0 instead of adding the entire LLBs you should just add the _Word Dynamic VIs.vi and _Excel Dynamic VIs.vi as dynamic VIs.  I think I've seen a similar post on the discussion forums in the past that recommended this.
    If this suggestion doesn't help, please reply, and attach a simple VI and .lvproj file demonstrating the problem so I can investigate further.
    Good luck,
    -D
    Darren Nattinger, CLA
    LabVIEW Artisan and Nugget Penman

  • File Dialog and Report Generation Toolkit

    Hi,
    I designed a VI for an electrometer calibration and it works quite well The only problem I have is the following:
    I used the Report Generation Toolkit to put the measurement data in an Excel file. When I run the VI I'd like a window to pop up to define the location and name of the Excel report file. If these two things are done LabVIEW should create the specified Excel file and run the rest of the code.
    So i tried this with the "File Dialog" Vi and all the needed low-level File I/O VIs and it worked.
    But when i connect the "File Dialog" VI with the "New Report" VI of the Report Generation Toolkit I get an error message.
    Is there any solution to get this file dialog pop up window with the Report Generation VIs?
    thx for any help...!
    Message Edited by Flea on 12-15-2005 03:58 AM

    Wow, thanks for your fast and very helpful reply devchander!
    I already tried this and it works fine
    thx!

  • LabVIEW 8.6 and report generation toolkit

    I was wanting to upgrade to 8.6 but noticed that my rep gen toolkit(1.1.1) is not compatible.
    Will NI be offering a free upgrade? or do I have to go to management and ask to purchase rep gen toolkit 1.1.3 for 500 US dollars?  Purchasing the same toolkit every few years when you have an SSP for a full development system is getting kind of old.
    Brian

    Unfortunately there is some delay in us Aussies getting the original DVDs sent to us, so at this stage my NI rep has burned me a copy of the main LabVIEW install but I can't find the Report Toolkit on it.
    I am an SSP customer but when I go to the Services Resource Centre I get this message:
    Important Message
    Access to the Services Resource Center could not be verified.
    The email address is not subscribed and/or activated with the appropriate level of service. If this is the incorrect email address, please login here
    Please confirm that your correct country information is specified, please select here
    If you have just subscribed you may need to wait up to 48 hours for your subscription to be processed
    If access is urgent, or to subscribe, please contact a NI Representative at (800) 206-2179. Outside of the US and Canada please contact your local NI branch office

  • Report Generation Toolkit and Office 10 - build errors

    Using LabView 2011 and Report Generation Toolkit 2011.
    After installing Office 10, I would get build error for Excel-Print.Vi and Excel-SetCell.vi and build is then aborted.
    2011/vi.lib/addons/_office/_excelsub.llb/Excel-Print.vi.
    Says it is unable to save a vi without a block diagram.
    Uninstalled Office 10 and reinstalled Office 2003 and build went thru just fine.
    I can program using Excel 2003 and the compiled executable will work on another computer with Excel 2011 but once I install Office 10 on my LabVIEW computer I cannot build.
    Can't believe I could be the only one to experience this. Any workarounds?

    Duplicate Post

  • Report Generation Toolkit and Applicatio​n Builder

    I am going insane trying to work this out.
    I am trying to build an EXE program using Application Builder. The program uses the Office Report Generation Toolkit.
    I have tried including the dynamic VIs into the project, both from the Development machine and from the CD. I still have the same problem : the application does not start Excel. It is like the commands go into a black hole. There isn't even an error message.
    I have attached my report VI for you to peruse. Any help is appreciated.
    Brian Rose
    Solved!
    Go to Solution.
    Attachments:
    TestReport.vi ‏122 KB

    Yes, Labview 8.2
    Office Toolkit = 1.1.1
    I have tried many combinations of what files are included, from just the top level VI, to every VI in the heirarchy tree (a major pain). I am now trying to rebuild the project from scratch and see if that does anything.
    Brian Rose

  • Application builder-Office report generation toolkit

    Hi,
    I remember there was a trick to get the executable work with different
    versions of Microsoft office but I cannot find it now. The problem it to get
    the exe work with some other office version that it was made. I use LabVIEW
    7.0 - 7.1 and Report generation toolkit 1.01 for Microsoft office. Was that
    possible?
    Thanks Eki

    Eki,
    When you use the Report Generation Toolkit to build a stand-alone application with the Application Builder, you must add _Word Dynamic VIs.vi from _wordsub.llb and _Excel Dynamic VIs.vi from _exclsub.llb as dynamic VIs. These two VIs contain subVIs that are called dynamically by the high-level Report Generation VIs. I believe that if you grab these VIs from the (desired office version part of the) installation CD instead of from the development machine, then everything should work.
    Zvezdana S.

  • Report Generation Toolkit Excel Vi's do not run after creating an executable​. What am I missing?

    I have labview 8.5 and Report Generation Toolkit version 1.1.2.   My vi works fine during development. When I make an executable or an installer the excel vi's do not work. I have seen this question posted before but it has always been for earlier revisions and the answers do not seem to apply with 8.5 and 1.1.2. 

    Hello ajh,
    You will have to include Dynamic VIs in the executable you build. The following link has more information:
    http://digital.ni.com/public.nsf/allkb/C38CE3F3054​2D65B86256F0E00740DD8
    Prashant.

  • Problem with report generation toolkit when installed new office 2010

    Dear all, I had  LabView 8.6.1 and report generation toolkit for MSoffice 2003 perfectly working in my laptop.
    Now I have added MSoffice 2010 and report generation toolkit does not work anymore since it is linked to new office.
    How can I inform Labview to link report generation toolkit to the old  MSoffice 2003?
    regards
    Max

    The Report Generation Toolkit is ActiveX based.  When you install the newest version of Office it registers the ActiveX server for that software, which the toolkit adapts to and uses.
    Uninstalling Office 2010 would solve the issue, otherwise you will need to look at unregistering the 2010 component of Office ActiveX - but I'm not sure if that's possible.
    Regards,
    Peter D

  • 800706BA RPC server unavailable in Report Generation toolkit

    Hi all,
    I've got a problem with LabVIEW 7.1.1 and Report Generation Toolkit (RGTK).RGTK is used to connect to MS-Word, create a new document from template and report test results. Works like a charme when stying local on the respective test machine.
    LabVIEWs 'Automation Open' node as wella as other parts of the RGTK have an control 'machine name' so I suspected I could bring a report server into game. Tried it and get an error "0x800706BA - The RPC server is unavailable in myTestVI" (translated from German Windows error).
    All the required subVIs to create a document have been put into a small test app. This one runs fine when running on the desired report server, but fail when opened and run on the devellopment machine.
    I have searched extensively for that error code and have changed some port settings in the firewalls and some services settings with no success. Can anyone help me out?
    BTW, on the remote machine a new process named WINWORD is started, but nothing more.
    TIA!

    Hi Lul,
    The error 0x800706BA is, as you said, a windows error (and, btw, your translation was correct as the original title is "The RPC server is unavailable").
    You can try to fix it with MicrosoftFixit :
    http://go.microsoft.com/?linkid=9666880
    Beside, more links that could be of some use :
    Windows Update error 800706BA:
    http://windows.microsoft.com/en-US/windows7/Windows-Update-error-800706BA
    Microsoft answer about error 800706BA:
    http://answers.microsoft.com/en-us/windows/forum/windows_other-windows_update/microsoft-updates-fail...
    In addition, a KB which is also related to this "RPC Server unavailable" in our IT database:
    How to fix MSI software update registration corruption issues:
    http://support.microsoft.com/kb/971187
    Regards
    Florian Abry
    Application Engineer Group Leader
    NI Germany

  • Hide Excel Chart Legend Using LabVIEW Report Generation Toolkit or Active

    Hello Eveyone:
    I work on the report generation toolkit in labview and creat the report in excle. I create the chart into report but I can't hide the chart legend or change the font size using report generation toolkit.
    I appriciate you guys time.
    Thanks
    Solved!
    Go to Solution.

    Howdy!
    What is the version of LabVIEW and Report Generation Toolkit you are using? Have you taken a look at the LabVIEW Example Column Graph (Excel).vi
    and looked at the help for Excel Insert Graph VI and Excel Set Graph Font?
    Joshua B.
    National Instruments
    NI Services
    NI Support Resources
    NI Training Resources

  • Report Generation Toolkit and App Builder question..

    Hello,
    I am in process of modifying my test code for writing my data to Excel. When I first developed the tests I did not have the Report Toolkit of Excel so I built the ActiveX VIs I needed. Now since I have upgraded to 7.1.1 with the MSOffice Toolkit I am rewriting my test code to use the toolkit VIs as it seems to work much better and faster then what I had done.
    My question is this. Since I have my testcode distributed to multiple machines when I build my App, do I need to add every Dynamic VI within the toolkit to my App? if so is there and simple way to find exactly which dynamically called VIs are used within the toolkit VIs?
    Thanks
    Jeff
    Jeff D.
    OS: Win 7 Ultimate
    LabVIEW Version: 2011,2010,2009 installed
    Certified LabVIEW Architect

    Greetings jdebuhr ,
    I'm using LabView 7 and have the report generation toolkit, In the "Report Generation Toolkit User Guide.pdf" manual under the title Cearating stand alone applications you 'll find the names and the path of the required dynamic VIs to be included in your EXE file (using appliocation builder)
    Check this manual.
    Ayman Mohammad Metwally
    Automation Engineer
    Egypt - Cairo

  • Exe build with database conn and report generation vi's?

    I tried to build an .exe and learned the hard way that there are many things needed to be included for this to work.  As is now my program is not working.
    I wanted to get a list of necessary steps to make a successful build.  Please correct me if I am wrong or missing anything:
    1.  For the report generation toolkit I must include a few support files (_exclsub.llb and _wordsub.llb)
    2.  For the database connectivity:  I must follow NI's User guide by implementing the toolset build script function?  Is there an easier way?
    If there are any simpler ways to get this working please let me know.
    Dev machine=vista LV2010 office 2007
    Target machine=XP office 2007
    Solved!
    Go to Solution.

    Thanks for the response,
    Yes I have the runtime installed.  I also got the program working correctly by doing the following:
    LV 8.6 and greater-->
    1.  added two folders to the project from the project explorer menu.
          a.  Utilities folder
          b.  LVClass folder
    2.  during the .exe build I had to:
          a.  add LVClass folder to always include in source file settings
          b.  browse in the Utilities folder to NIReportLLB folder and add that to always include as mentioned above (note:  if you add the whole utilities folder you will get a broken vi error when building it, even if you fix the vi it still didn't work properly for me so I just included the folder I needed for word/excel)
    took about a day to troubleshoot and fix but the program is working as expected.  Hope this helps someone else in the future.
    Bernie

  • Application doesn't work after build (database toolkit and report gen toolkit).

    I wrote an application using database toolkit and report gen toolkit to retrieve some data from a database,  put into a Word doc, save the Word doc and print it.  It works fine when I run the vi, but when I build and run it, it does nothing.   I have tried all of the settings in Projec Manager that I think might help but it still won't work right.  Labview 8.2.1, XP.
    Thanks,
    Charlie
    Solved!
    Go to Solution.

    Thanks for the help.  I finally abondened the Word append table and used the regular report gen append table and got it to work fine.  The error was 214682314.  That led me to the thread about column numbers must vbe between 1 and 63, but like I said, my coulumn number is 7 so don't know what is going on.  Anyway I got the vi to work and do what I want so I guess now the problem is solved (moot).
    Charlie

  • Report generation toolkit and signal express user step : problem of closing reference in "Stop" event

    Hi all,
    I'm trying to make a package of Vis to easily make Excel reports with Signal Express. I'm working on LabVIEW 8.2.1.
    I'm using the report generation toolkit, so I build a .llb from my project which contains all the hierarchy of my steps, but also the hierarchy of dynamic VIs called.
    I have made some steps, like "Open Workbook", "Write Data", etc.
    My steps run well, excepts one step : "Close Workbook".
    If my "Close Workbook" step is firing on "Run" Signal Express event, I have no error, so my reference is properly closed.
    But if my "Close Workbook" step is firing on "Stop" Signal Express event, I have an error "1", from "Generate Report Objectrepository.vi".
    I feel that I'm trying to use a reference which has been killed in the "Stop" step...
    I would like to know what exactly do Signal Express on "Stop" event and why my close function does'nt run well.
    Thanks,
    Callahan

    Hi Callahan,
    SignalExpress (SE for short) does the following on the Stop event:
    1. Takes the list of parameters that SE found on your VI's connector pane, and sets the values that the user set from the "Run LabVIEW VI" configuration page, if any.
    2. Then tells the VI that SE is running the Stop event by setting the Enum found on your VI's front panel. This in turn should produce some boolean values telling your VI to execute the Stop case.
    3. The VI is then run, with those values and states.
    4. SE checks to see if any errors where returned.
    5. Since this is the Stop event, SE releases the reference to the VI which it possesses.
    Questions for you would be, is the reference to your Workbook linked to a control on your connector pane, or held in a uninitialized Shift Register. If it's held in a Shift Register, SE would not be aware of it, and would not be able to affect that reference.
    Hope that helps. Feel free to post your LLB if it doesn't.
    Phil

Maybe you are looking for

  • Will I be able to transfer movies from a windows pc to my iPad?

    And how would I do that? And what does iTunes have to do with it? Do i have to install another app from the store to make that video work on my iPad? Sorry I'm really new to this Been an android user and was just used to dragging and dropping files.

  • Product master in CRM and R/3

    Hi Gurus, can anybody make my understanding clear regarding  the difference of product master in CRM and R/3. any links to know more on it will also help. Thank you in advance. Regards, sasmita

  • Clarifications in External Reconciliations

    Hi experts, Need your valuable suggestions for the below raised situation in Banking reconciliations. One of our client is doing bank external reconciliation through Manual Reconciliation. Last time when he is doing the reconciliation, he selected th

  • Account Manager Question

    If I am the account manager can anyone make changes from their phone?  I have recently noticed that my other lines phone calls are not showing up.  They are there and it tells me how long they were on the phone but there is no phone number. help...th

  • Abap proxy with attachments in enhanced interface determination/mapping

    Hi guys. We were receiving a abap proxy from ECC with a pdf attached in the header. This was the scenario PROXY ---> FILE We used the PayloadSwapBean Module in a Receiver File Adapter to get this document and put it in a FTP Server. Now we have to ma