Can we pass data-parameter in host

Can we pass a data-parameter to a report using host command in the form.
urgent please
vishal

Your answer is quite correct, but it is stupid behavior - how do you build backwards compatibility into a function if you have to specify the keyword 'default'?
For example, I have an existing function that takes one parameter, but I need to alter it to take two parameters.   I work for a large bank that has a rigorous change management process, and this function resides in the data warehouse, so many
people can use this function in their code, and I need to ensure that any changes I make are backwards compatible, and don't break any existing code that I don't know about.
If this was a stored proc, I could call it without the optional parameter, and the default value would be applied, but a function needs me to specify the keyword 'default' or to provide a value.
My only option seems to be to create a wrapper function that calls either the old function (if only one parameter is provided) or the new function (if both parameters are provided).   Sort of defeats the purpose of having default or optional values.

Similar Messages

  • How can i pass a parameter to the query to filter the result of this lookup

    Hello,
    i'm developping a web application with JDeveloper 10.1.2 and JHeadStart.
    i realy need to know how can i filter the lookup (LOV) query result.
    in other word, when i click on the lookup, it show all the row that exist in may data base table.
    what i want is how can i pass a parameter to the query to filter the result of this lookup ?
    Thank you

    Hi,
    have a look if this helps
    http://oracle.com/technology/products/jdev/tips/fnimphius/restrictlovlist/restrictlov.html
    Frank

  • Passing data parameter between SWF files

    Hello Xcelsius Gurus,
    Is it possible to pass data parameter between SWF files?
    If possible, how to achieve it?
    Thank you.
    Justine

    Hi,
    Thank you for the reference.  Little bit confused, please let me clarify. 
    I do not understand how the receiver SWF receieved the data parameter and process.
    For example, I have a parent dashboard and a child dashboard.  In the parent dashboard, I have set up combo box to filter the data.  And I want the data that I have selected in combo box to the child dashboard.
    To do this, first I need to setup the flash variable at the parent dashboard to fetch the data I selected.
    After this, how to link this data to the child dashboard?
    Furthermore, after the child dashboard received the data parameter, I need this data to insert into the spreadsheet so I can filter the data.  Is this possible?
    Thanks.
    Edited by: Justine Liu on Jan 19, 2010 3:11 PM

  • How to pass date parameter from one page to other in BSP application

    Hello gurus,
    In my BSP application i have taken an input field and made its type "date" and its value also of type date and have set showhelp .
    Now once a particular date is given as an input i want to pass its value to next page. And in next page i have to fire a query based on the date entered in previous page...
    Now my prb is that my date value is not getting passed to the next page.
    I have used
    navigation->set_parameter( name = 'BEGDA' value = BEGDA ).
    to pass date parameter.....still parameter is not getting passed.
    plz help me with this.....
    thankx.....

    Hi Eddy,
    By truncation i mean the entire date becomes 10 char including the ' . ' eg(06.12.2006).
    so with begda being 8chars it takes my date as 06.12.200
    as a result my query is not getting executed.
    now i have tried to use a FM  'CONVERT_DATE_TO_INTERN_FORMAT'.
    in my 1st page but still in 2nd page its giving me following error.
    <b>The data that was read could not be written to the specified target field during a SELECT access. Either the conversion is not supported for the type of the target field, or the target field is too short to accept the value, or the data is not in the appropriateformat for the target field.
    </b>
    Regards
    Swati

  • Error: can't fetch data for this host - too few bytes supplied by RPC

    Hi,
    In our internal Lab we have:
    One Admin, Media,Client Server (we can make backups for himself) - Solaris 10 with DDS4 tape drive (lab)
    One Windows Client (we can make backups) - Windows XP
    One Linux Client - CentOS 5.1
    When we add the linux client with the command:
    mkhost -a ob --inservice -r client -k 1024 linux
    We receive this message in the linux (host) /usr/tmp/observiced.log
    Error: can't fetch data for this host - too few bytes supplied by RPC partner (OB cached object manager)
    And in the obtool we receive (forever looping)
    Info: waiting for host to update certification status...
    Can you help us with this linux client error ? (iptables and selinux disabled!!)
    Thanks in Advance
    Serpins

    [SOLVED]
    Selinux not well removed....
    Thanks in Advance
    Serpins

  • How can i pass the  parameter for strored procedure from java

    dear all,
    I am very new for stored procedure
    1. I want to write the strored procedure for insert.
    2. How can i pass the parameter for that procedure from java.
    if any material available in internet create procedure and call procedure from java , and passing parameter to procedure from java

    Hi Ram,
    To call the callable statement use the below sample.
    stmt = conn.prepareCall("{call <procedure name>(?,?)}");
    stmt.setString(1,value);//Input parameter
    stmt.registerOutParameter(2,Types.BIGINT);//Output parameter
    stmt.execute();
    seq = (int)stmt.getLong(2);//Getting the result from the procedure.

  • Can I pass a parameter to a mapping without using a process flow?

    I have to load data from multiple countries at different times. Rather than creating an individual mapping for each country, I want to create 1 mapping and pass the country code as a parameter to the mapping. I tried to use an input parameter in the mapping and add a custom parameter to the sqlplus_exec_template hoping the custom parameter would pass to the mapping input parameter but it's not working. No data loads.
    When I add a default value to the input parameter, the data loads but this isn't the solution I need. The value of the parameter will vary depending on the country so I can't use defaults. Since the mappings load automatically, I need the script to be able to pass the parameter in.
    I'm trying to avoid going through a process flow because that just seems like overkill for what I need to do. I just want to load all the data where country code = 'X'. Is this even possible?

    o.k. I tried everything to see which would be the best scenario.
    Zeppo - I can't use your solution because ".main", I believe, applies to an older version of OWB. We have 10g. I know in 3.1 ".main" applies because I still have mappings from that version. Doesn't apply to 10g.
    Sutirtha - I set the property for the prompt but it still didn't work.
    MccM - Yes, the premapping process works perfectly. Only thing is that I have to come up with so many different scenarios in the If then else logic. Giving me a migraine ...
    .... so ....
    I punked out and created a table that stores all of the load times by country code. In the joiner, I linked the table's country code to the country code in my view and only retrieved data where the table's load hour equals the sysdate hour. Now all I have to do is change an entry in the working table if I need to reschedule a load.
    It's cluggy but it works ... and I met me goal of only using 1 mapping.
    Thanks to all of you for providing your input. Much appreciated.

  • How to pass date parameter in URL in system date format

    Hi All,
    I am working on a requirement where I need to pass the date parameter in URL. Where date format needs to be system default date format. How can we format date without providing specific date format.
    Also, I got some post which had below example. Can you let me know what this format does.
    '/analysis/report?queryGroupName=Custom-ProjectInfo&TimePeriodBeginning=', <%+%> FCI_CHARFMT(TIME_PERIOD_START_DATE),' <%+%>
    '&TimePeriodBeginning_format=17&link_crumb=true'
    Waiting for response.
    Thanks,
    Saloni

    Hi,
    If you're running this in SQL*Plus, you can use substitution variables.
    If you have a file called my_query.sql, like this
    select    A.agent_no,
              (a.first_name || A.agent_name)     as agent_Name,
              P.Policy_No,
              D.Driver_No,
              D.mvr_predict_score,
           D.mvr_received
    from        policy  P,
           agent   A,
           Driver  D
    where       D.request_mvr_hit   = 'M'
    AND       D.mvr_predict_Score > 540
    And       D.request_mvr          = 'D'
    AND        p.fullkey           = d.fullkey
    AND       p.agent_no          = a.agent_no
    AND       d.mvr_received     >= TO_DATE ('&1', 'DD-Mon-YYYY')          -- New
    AND       d.mvr_received     <  TO_DATE ('&2', 'DD-Mon-YYYY') + 1     -- New
    order by  a.agent_no,
                 CASE  a.producer_type
               when  'S'  then 1
               when  'C'  then 2
               when  'R'  then 3
           end
    ;Then you can run it from SQL*Plus by saying something like:
    @my_query  1-Jan-2009  31-Dec-2009&1 in the script will be replace by the 1st argument (1-Jan-2009) and &2 will be replaced by the 2nd argument (31-Dec-2009).
    Notice that the last condition adds 1 to the argument
    AND       d.mvr_received     <  TO_DATE ('&2', 'DD-Mon-YYYY') + 1     -- Newbut uses the < operator (not <=). The result is that if mvr_received is any time on the last day (e.g. 31-Dec-2009 11:59 pm) will be included.

  • To pass date parameter to thew SQ:L of a reprt file through form

    I want a layman user to enter a date parameter in a Form and the parameter to be passed on to the SQL of a report file, so that a new report is created. How to do that?

    Let the user enter the date as Varchar2 or as Date itself. You create the parameter list to pass this value as Text parameter to the report.
    Now, use this text parameter as the input to your WHERE clause of the report SQL. You can compare it with the date field by converting it as a date using TO_DATE() function or vise-versa.
    Eg:
    SELECT * FROM emp WHERE join_dt=TO_CHAR(:mdate,'DD-MON-YYY');
    or
    SELECT * FROM emp WHERE TO_CHAR(join_dt,'<date format used>')=:mdate;
    Hope this works
    Regards,
    APK

  • Pass data parameter from URL to Forms

    Hi
    Is it possible to pass a data parameter from asp to Forms?.
    In my asp I have a url to call a form (eg. http://servername:port/forms90/f90servlet/form=testform.fmx). In my testform.fmx I accept 'account no' as a parameter for querying the records. Since I am calling this form from asp, I already have the account no in my asp. I would like to pass this account no to the form automatically.
    Is it possible to pass this data parameter from url to forms?.
    If possible, what changes to be made in the form. Please help.
    sreekumar

    Create a parameter in your form, there's a node for it in the Navigator window. Imagine it is called myParam.
    Pass it on the URL like this:
    http://host/forms90/f90servlet?config=myApp&otherParams=myParam=somevalue
    Regards,
    Robin Zimmermann
    Forms Product Management

  • How to auto login and pass data (parameter) to ApEx at the same time

    Does anybody know how to automatically login to apex (e.g. from JSP page) and pass a parameter value at the same time? I can use wwv_flow_custom_auth_std to login, I can even choose a page but I cannot pass any data (at least I do not know how). If I use f?p URL syntax I can pass data but there is no way to pass login/password information.
    Any idea? Thanks Jaros

    Jaros -
    You could copy your login page and make the new page "public". On the new page, add a process before the login process that sets the value of application item FSP_AFTER_LOGIN_URL to the report page URL (with the arguments), e.g.,   :FSP_AFTER_LOGIN_URL := 'f?p=&APP_ID.:100:&SESSION.::NO::P100_X,P100_Y:&RPT_VALUE1.,&RPT_VALUE2.';Create application-level items RPT_VALUE1 and RPT_VALUE2 in the application.
    From your external page, POST to this new "login" page, passing values for the username, password, rpt_value1, and rpt_value2 items.
    Let us know if it works.
    Scott

  • RT - How can I make data transfer to host faster?

    Hi 
    I have created a program that acquires data on FPGA then transfers them to RT so RT can send them up to the windows host once UI is connected.
    The program is based on message type structure as in NI's examples.
    However, I have one problem the data to windows host is not transferred fast enough.
    Pic1 shows the offending bit of code and FPGA.png what's hiding in the subVi.
    FPGA is meant to acquire to cycles of a sine wave. In this case it approximately 40 ms of data at 25us sampling rate (40kS/s 8 channels). Later the data is sent to the host. As you can see I have a dedicated stream for data only and a different one for message passing.
    If I disable the code in the case structure this loop executes in 39-40 ms, however when I start sending the data to the host the rate drops to 57-60 ms per iteration and that sooner or later leads to buffer overflow.
    I have experimented with passing the acquired data to a different loop using a queue but that wasn't faster. I have also tried pipelining but that did not speed it up either. Would you have any suggestions how I could improve my transfer rates?
    Thank you.
    Bartosz
    Attachments:
    Pic1.png ‏100 KB
    FPGA.png ‏75 KB

    Hi barteklul,
    There are 2 main methods of achieving fast data transfer between RT and Host PC:
    1. Using the "Shared Variables", they allow you to transfer data deterministically from
    RT to Host PC, usually are used to monitor data.
    Please have a look at this article:
    http://zone.ni.com/reference/en-XX/help/370622J-01/lvrtconcepts/rt_projectvariable/
    This is the example code:
    https://decibel.ni.com/content/docs/DOC-15928
    The only disadvantage of such method is that if for example RT gets data really fast
    your Host PC can miss some samples.
    2. In order to receive all data from RT
    (guaranteed 100% data transfer without missing any samples) "Network Streams" should be used.
    It is a little bit more complex to implement, but if you want to store data to the file "Network Streams"
    are strongly suggested. In addition "Network Streams" are not deterministic.
    For more details about network streams please read this article:
    http://www.ni.com/white-paper/12267/en/
    At the moment I see that you are using "Network Streams" to transfer data and also I can see that you have some timing on RT
    which can slow down the data transfer rate. I suggest you to transfer data to Host PC as soon as it comes into the FIFO.
    Also if you transfer data just to monitor it, I suggest you to try Shared Variables method.
    I hope that you will this information useful!
    Kind Regards,
    Max
    Applications Engineer
    National Instruments

  • Can not pass data after while loop

    Hello.
    I have created a VI for my experiment and am having problem passing data outside a while loop to save on an excel file. The VI needs to first move a probe radially, take data at 1mm increment, then move axially, take data radially at 1mm increment, then move to the next axial position and repeat. It would then export these data to an excel file. The VI is a little complicated but it's the only way I know how to make it for our experiment. I have tested it and all the motion works correctly, however I can not get it to pass the data after the last while loop on the far right of the VI where I have put the arrows (Please see the attached VI ). Is it because I'm using too many sequence, case, and while loops?  If so, what other ways can I use to make it export data to the excel file?
    Any help would be appreciated. 
    Thank you,
    Max
    Attachments:
    B.Dot.Probe.Exp.vi ‏66 KB

    Ummmm .... gee, I'm not even sure where to begin with this one. Your VI is well .... ummmm... You have straight wires! That's always nice to see. As for everything else. Well... Your fundamental problem is lack of understanding of dataflow programming. What you've created is a text program. It would look fantastic in C. In LabVIEW it makes my heart break. For a direct answer to your question: Data will not show up outside a while loop until the while loop has completed. This means your most likely problem is that the conditions to stop that specific loop are not being met. As for what the problem is, I don't even want to start debugging this code. Of course, one way to pass data outside of loops is with local variables, and hey, you seem to be having so much fun with those, what's one more?
    This may sound harsh, and perhaps be somewhat insulting, but the brutal truth is that what I would personally do is to throw it out and to start using a good architecture like a state machine. This kind of framework is easy to code, easy to modify, and easy to debug. All qualities that your code seems to lack.
    Message Edited by smercurio_fc on 08-17-2009 10:00 PM

  • Passing date parameter from prompt

    Hi experts
    I am getting some problem while passing date from a dashboard prompt.
    In RPD i have changed the date column properties as DATE only so that i will get the DATE part of the data not the time stamp.
    Now in the dashboard prompt i added a prompt for the date column.
    I initialized the date prompt with a server variable of sysdate
    when i am running the dashboard i am getting default value in the prompt(04/15/2011)
    when i am changing the date it is selected as(04/15/2011)
    but when i am clicking the 'Go' button the date is converting to 2011-04-15 00:00:00 due to which my report is not running and i am getting error as
    View Display Error
    A date value was expected (received "2011-04-15 00:00:00").
    Error Details
    Error Codes: QABPH2PO
    can anyone help me to pass only date part
    thanks in advance
    regards
    Gourisankar

    Hi J / Srikanth
    Sorry to restart the thread again.
    As we discussed i have downloaded the patch and applied to my windows 32 bit machine.
    But now when i run the report the report is running only for the default value(Server Variable) which is specified to the prompt. when i change the date there is no effect to the report.
    When i drill down to the report i found that the date column(is prompted) is changed to teh server variable name which is might be the cause.
    any input on this???
    regards
    Gourisankar

  • Passing date parameter from forms to report

    Hi,
    I'm using forms and reports 6i.
    I want to pass one date parameter from forms to reports.
    Using
    Add_Parameter(pl_id,'P_FROM_DATE',TEXT_PARAMETER,:FROM_DT);
    giving me error REP-0091- Invalid value for parameter 'P_FROM_DATE'
    This i think is because report expects date and here it is converted as varchar.
    Please help

    Hi Divya,
    Even I use this kind of statement
    Add_Parameter(pl_id,'P_FROM_DATE',TEXT_PARAMETER,:FROM_DT);and works fine for me.
    This i think is because report expects date and here it is converted as varchar
    Correct.
    Open the report in the builder and under Data Model -> User Parameters, Go to the Property Inspector of P_FROM_DATE. Under Parameter, set Datatype as Character instead of Date.
    Hope this should work. and tell me if it works(coz it wokred for me).