Cannot download LabVIEW NI SoftMotion Module 2011 SP1
LabVIEW NI SoftMotion Module 2011 SP1
http://joule.ni.com/nidu/cds/view/p/id/2776/lang/en/rating/1
All link in this page you can download is a downloader, and the downloader can only download it self.
A CLA from China
Solved!
Go to Solution.
Hi,
I'm not sure what is going on. For now, please download the NI SoftMotion Module from the following link: https://lumen.ni.com/nicif/us/EVALTLKTINDCTRL/content.xhtml
I have verified that this works.
Thanks,
Paul B.
Motion Control R&D
Similar Messages
-
Hi,
i got this problem when i want to deploy the project with softmotion
https://www.dropbox.com/s/at9r9w667i00qja/qqqqqq.png
NI SoftMotion: The version of the LabVIEW NI SoftMotion Module installed on the host differs from the version installed on the RT target.Hi Eng.Tareq
It would be better if you can give more information
1. What is the software version are you using?
2. What is your target hardware?
You can check the above information by open MAX -> under software tab of both computer and you target
I suspect that the software version of your host computer and the target is difference as state in the picture attached.
TuiTui -
Cannot activate Labview after update to 2012 SP1
Hello
I just updated from Labview 2012 Spring edition to Labview 2012 SP1 as suggested by the NI Uodate Service, and when it came to activate the product, the activation wizard tells me that the serial number does not match the software. I don't have any other serial. It is an academic license.
Thank you in advnace for your help
Regards
HelderCnyc wrote:
SSP = Standar Service Program http://www.ni.com/services/software_benefits.htm
Here is NI's webpage about LabVIEW 2012SP1 http://www.ni.com/labview/release-details/
LabVIEW 2012 Service Pack 1 is an exclusive update to LabVIEW 2012 for NI Standard Service Program (SSP) customers. There are no new product features introduced in service pack releases; instead, these releases provide bug fixes and improved stability for LabVIEW 2012.
In my opinion, bug fixes for a specific release such as LabVIEW 2012 should be FREE; NI has chosen to be yet another greedy company.
I have to agree. Your words were more opinionated than mine, but yes, I agree with you.
Bill
(Mid-Level minion.)
My support system ensures that I don't look totally incompetent.
Proud to say that I've progressed beyond knowing just enough to be dangerous. I now know enough to know that I have no clue about anything at all. -
LabVIEW SoftMotion Module version for CompactRIO 13.1
Dear all,
I'm trying to use deploy a C-module 9512, which is installed in a cRIO 9024 and NI 9114 chassis.
I would like to get access to the interactive test panel, but whenever i try to do this it won't let me deploy the unit.
I get an error message as follows:
"LabVIEW: (Hex 0x80DF001E) The deployment plug-in for this item cannot be found. Verify the proper software is installed. Deployment completed with errors",
which leaves me unable to access the test panel.
I have LabView 2013 SP1 (13.0.1), NI CompactRIO 13.1 [NI-RIO 13.1], and LabVIEW Real-Time 13.0.1, installed. I also download Softmotion Module 2013 SP1 on the host, but it cannot be installed on the cRIO (see attached: SoftMotion_version_for_cRIO-RT.jpg).
To see the software installed on the cRIO, see the attached image (see attached: cRIO_installed_software.jpg)
Any idea of what i'm doing wrong? Thanks a lot!
Best Regards,
Michael
Attachments:
SoftMotion_version_for_cRIO-RT.JPG 75 KB
cRIO_installed_software.JPG 153 KBYou've posted to the wrong board. This is for conversion between different versions of LabVIEW.
-
Hello all
i am using labview 2010 32 bit, windows 7 64bit, ni softmotion module 2010 f1, and solidworks 2011
after installing ni softmotion module I tried open one example and deploy the axis. After pressing deploy option it shows one error and after cliking ok in that error it terminates all programs associated with labview. How can overcome this problem.?
Can anyone help me in this regards?
Thank you
Attachments:
error.jpg 272 KBHi,
I'm not sure what is going on. For now, please download the NI SoftMotion Module from the following link: https://lumen.ni.com/nicif/us/EVALTLKTINDCTRL/content.xhtml
I have verified that this works.
Thanks,
Paul B.
Motion Control R&D -
Velocity profiling with SoftMotion Module
Hi Folk,
I need to move a stepper motor following a velocity profile, i.e. I need to change continuously the velocity while motion is in progress.
I intend to perform the move with a cRIO platform equipped with a NI 9512 module.
By using the property & invoke nodes, introduced first in NI SoftMotion Module 2009 SP1, I have created a small test routine to perform my task.
I have used the property & invoke nodes, instead of the function blocks, because I want to update the velocity profile as fast as possible.
For the test routine I have used a simulated axis (a servo motor) and the routine is developed by using the scan interface.
In the main loop, a sinusoidal wave (point by point) generates a sample velocity profile, the velocity is passed to the "velocity" Straigth-Line Move property node and it is applied to the axis by the "Start" Straigth-Line Move invoke node.
The test routine runs circa correctly until the velocity profile cross the zero, at that time the routine stops with the following Error -77070.
I have added an offset to the generated sinusoidal profile. The test routine runs correctly if the offset sets the sinusoidal profile all positive or all negative, i.e. the offset is greater than sinusoidal amplitude.
Question (1)
I beleave that this behavior is due to a bug in the Straigth-Line Move node. I am right?
Question (2)
I have written that the routine runs "circa" correctly because furthermore the previous bug there is a timing issue.
I have set the Scan Period = 5 ms as it is requested for 951x modules.
If the timed loop (Synchronize to Scan Engine) is set to 5 scans or more the timing of the timed loop seems to be correct (the sinusoidal wave shows the period that has been configured).
If the timed loop is set to 4 scans or less the timing of the timed loop becomes longer (the sinusoidal wave shows a longer period as that has been configured).
Any idea about this timing issue?
Question (3)
Any suggestion how to write a faster velocity profiling with the SoftMotion Module?
Thanks for your help,
Asper
P.S.
Error -77070 occurred at Invoke Node in Axis_Velocity_profiling.vi
Possible reason(s):
NI SoftMotion: A Start operation is pending. Please add a delay between consecutive preemptive Start Motion calls.
Attachments:
velocity_profile_exemple.zip 77 KBHi Reid,
I am developing a system for low-force tests of very thin tissues in tension and fatigue.
The force is measured with a load cell and is applied by pulling the sample with a linear translation stage and the elongation is measured with a linear encoder.
The linear stage is motorized with a 2-phase-stepper motor, and with two limit switches. The stepper is designed for applications with very limited space conditions and the motor is hollow.
The linear encoder has a 20 nm resolution and a 1 um accuracy, and includes an electronic for signal conditioning that is compliant with the encoder input of the NI 9512 module.
The load cell is a full bridge with an accuracy better than 0.01 %. For acquiring and conditioning the full bridge, the system uses a NI 9237.
The system will provide tests that are controlled both in force and in elongation.
For the tests controlled in force, the loop is closed with the signal measured by the load cell and the translation stage is driven in velocity.
For the tests controlled in elongation, the loop is closed with the encoder signal and the translation stage is driven in position.
For both type of tests, the user can select different test profiles, for example: a linear increasing, a sinusoidal profile for fatigue test, etc.
The user can pause the test at any time, and the system must take the condition, until the next proceed command.
My previous post: question (1)
Your reply:
I ran the code Axis Override Test 1 on my machine on a simulated Axis and this was the performance I observed:
Our versions maybe differing did you see the same behavior on a simulated axis?
Concerning the velocity that is read from the Read (Data) function block, I observe the following:
With a simulated axis (both in My computer and in cRIO-9073) the values are positive for forward move and they are negative for backward move (as you also have observed).
With the real axis (NI 9512) the values are positive both for forward move and backward move.
Please see the next images.
With simulated axis
With real axis (NI 9512)
My system is as follows:
LabVIEW: 9.0f3
SoftMotion: 9.0.1
NI-Motion: 8.1.0.3037
NI-RIO: 3.3.1
NI-RT: 9.0.0
I want to point out that the simulated-axis is a servo drive while the real axis is a stepper drive (NI 9512).
With my software release, I believe that this behavior is due to a bug, probably in the stepper drive interface. I am right?
I suggest that you try on a real stepper axis (NI 9512).
My previous post: question (2)
Your reply:
These two questions I feel share the same root cause. It takes a little bit longer to calculate the a preemptive move in the opposite direction.
Considering the observation on the Read (Data) function block issue, now I note that my second question arises from the sum of two different behaviors. In case the Read (Data) function block issue is solved, as for simulated axis, the sentence can be rewritten as:
The velocity plot shows some computation troubles as the velocity is approaching the zero, with the derivative both positive and negative.
Furthermore I have discovered that this computation troubles gives a blocking error if the velocity is approaching the zero with a zero derivative.
Once the velocity reaches the zero with a zero derivative, the "Velocity Override" Write is no any more able to change the velocity!
No errors or warnings comes out in this situation!
This behavior is true with an axis both real and simulated, and is still true both with an all function blocks code and a mixed function blocks/invoke nodes code.
From this point of view, the velocity troubles with the approaching to zero are very very bad!
Please consider that in the previous posted example you can find an all function blocks code, Axis Velocity Override_test_0.vi, and a mixed function blocks/invoke nodes code, Axis Velocity Override_test_1.vi.
You can easily test the velocity blocking error by putting the parameter offset = amplitude in the previous posted example.
My previous post: question (3)
Your reply:
I am curious if you are observing that around zero % the override function performs poorly, was this present on the function block example? I think the problem here is the preemptive move being called from the straightline move function. Basically, the trajectory generator is still calculating points when send the command to it. Since we are updating the velocity at a very fast interval we notice some of this breakup due to the longer latancy times. Even with this
Error -70216 occurred at an unidentified location
Possible reason(s):
Motion: A required resource is busy and unable to accept further commands at this time.
To get around this error you will need to call into the trajectory generator at a slower period of time to allow it to finish the operation in progress. Keep in mind the control loop we are calling into in RT is the command loop to the trajectory generator and the position control loop is performed on the FPGA of the module itself.
I want to underline that the computation troubles as the velocity is approaching the zero has not apparent connection with the Error -70216.
I have tested the posted routines with Scan Period = 5 ms and the Number of Scans = 5 or more (25 ms for cycle or more) and the computation trouble is still there every time that the velocity is approaching the zero.
The Error -70216 come out randomly and increases as the cycle time decreases.
I did not observe any decay in the time to perform the Velocity Override around zero %, but you have to consider that I did not make any test to investigate this issue.
I agree with you, the Error -70216 can arise from some commands that try to access the same resource a the same time.
In my opinion the Velocity Override has to be predominant, i.e. no matter what the routine is actually doing, the routine should start immediately to correct the actual velocity to reach the new value.
Suggestion: for the future release of the Velocity Override, please consider to leave the opportunity to select from percentage velocity (as it is now) an absolute velocity.
Regards,
Asper -
Need link to LabVIEW 2011 SP1 Windows 32-bit download
I have been looking for the link to LabVIEW 2011 SP1 Windows 32-bit download for an hour. I thought it might be incorporated into the SP1f2 version. Nope. SP1f1 version. Nope. The ni.com search can't find it, Google can't find it, I am stuck.
Certified LabVIEW Developer
NI-VLM Administrator
Solved!
Go to Solution.That I did not know. I guess the other question is even if you do have a right to the older version, would they not show up if you are not logged into NI.com at the time?
I would've figured that if you didn't have rights to a version, then you wouldn't be able to activate that version once you installed it. That you'd be left in evaluation mode. I didn't think that the website would block an attempt to download it.
EDIT:
I see that if you are not logged in, it says:
"Need previous versions? Access your SSP benefits by logging in." -
Only have LabVIEW 2012. Why am I asked to download LabVIEW 2011 SP1 f2 RTE Patch?
Hello,
I recently got a new machine (clean install of Windows 8), and installed LabVIEW 2012, with no other previous versions. However, when I ran the NI Update Service, it listed "LabVIEW 2011 SP1 f2 R(32-bit) Run-Time Engine Patch" as a critical update.
I'm confused; did I accidentally install LV 2011 too?
Thanks
Solved!
Go to Solution.Also, some addons use older RunTime Engines. It is not suprising that you need the 2011 RTE patch.
There are only two ways to tell somebody thanks: Kudos and Marked Solutions
Unofficial Forum Rules and Guidelines -
Cannot download updates in SCCM after SP1 Updrade
Hi all,
I have upgraded my SCCM 2012 RTM to SP1 last week and since then I cannot download updates.
It gives the error message "Error: Failed to download content id 16779439. Error: Access is denied
I have tried reinstalling WSUS onto the server which seems to be working fine, but I still cannot download the updates in SCCM.
I am a full administrator of SCCM and a domain admin on the Server itself.
Any help would be appreciated.
Thanks
RichardIm not sure what permissions I should be looking for, Everyone has read access to the foler, there is a Network Service account with full access, and other than that WSUS Administrators and Administrators groups have full access also.
Here is a sample of the logs:
Trying to connect to the root\SMS namespace on the AS024.smd.swanseamet.ac.uk machine. $$<Software Updates Patch Downloader><02-13-2013 11:04:48.236+00><thread=4648 (0x1228)>
Connected to \\AS024.smd.swanseamet.ac.uk\root\SMS $$<Software Updates Patch Downloader><02-13-2013 11:04:48.237+00><thread=4648 (0x1228)>
Trying to connect to the \\AS024.smd.swanseamet.ac.uk\root\sms\site_MP1 namespace on the AS024.smd.swanseamet.ac.uk machine. $$<Software Updates Patch Downloader><02-13-2013 11:04:48.240+00><thread=4648 (0x1228)>
Connected to \\AS024.smd.swanseamet.ac.uk\root\sms\site_MP1 $$<Software Updates Patch Downloader><02-13-2013 11:04:48.241+00><thread=4648 (0x1228)>
Download destination = \\as024\UpdateServicesPackages\6357efc3-8d00-4981-95ba-367b12372437.1\accessrtmuisp1-en-us.cab . $$<Software Updates Patch Downloader><02-13-2013 11:04:48.451+00><thread=4648 (0x1228)>
Contentsource = http://wsus.ds.download.windowsupdate.com/msdownload/update/software/svpk/2011/06/accessrtmuisp1-en-us_5e0a1bb39f2f7ac9a969410c26cc7d6ddf62c696.cab . $$<Software Updates Patch Downloader><02-13-2013 11:04:48.451+00><thread=4648
(0x1228)>
Downloading content for ContentID = 16779439, FileName = accessrtmuisp1-en-us.cab. $$<Software Updates Patch Downloader><02-13-2013 11:04:48.459+00><thread=4648 (0x1228)>
Failed to create directory \\as024\UpdateServicesPackages\6357efc3-8d00-4981-95ba-367b12372437.1\, error 5 $$<Software Updates Patch Downloader><02-13-2013 11:04:48.465+00><thread=4596 (0x11F4)>
ERROR: DownloadContentFiles() failed with hr=0x80070005 $$<Software Updates Patch Downloader><02-13-2013 11:04:48.466+00><thread=4648 (0x1228)>
I hope this is of some use.
Thanks
Richard -
Softmotion module only runs on labview 32 bit and not labview 64 bit
Good day everyone,
I downloaded the softmotion module for my Labview 2013 64 bit however when i try to create a new solidworks assembly there is no option for that.
But when I installed the 32 bit version of Labview 2013 I was able to see the option to create a new solidworks assembly.
Why can't I see the option for the Labview 2013 64 bit ?
P.S I am using Solidworks 2014 64 bit Premium .
Thanks
Below is the 64 bit
Below is the 32 bit
Solved!
Go to Solution.The softmotion module is not supported for 64-bit LabVIEW. You can see what we support in the link below.
http://www.ni.com/white-paper/10383/en/
Matt J
Professional Googler and Kudo Addict
National Instruments -
Error -1074397038 occurred at IMAQ Start.vi for 64bit Labview 2011 SP1, Win7
Hello,
I am using a MC1362 camera from Mikrotron with a PCIe1433 framegrabber. I was using it with windows XP, 32 bit, labview 2010 SP1 32 bit, it was working perfectly fine. I just switch to windows 7 with labview 2011 SP1 64bit, and it is not working anymore with my custom routine in labview, though it works with MAX and camera file generator and I use the same camera file.
When I run my routine, I have this error message:
Error -1074397038 occurred at IMAQ Start.vi
Possible reason(s):
NI-IMAQ: The requested serial termination string was not found in the returned buffer.
Then, If I try to run the camera with MAX, it doesn't work anymore, I have to reboot the camera, and put it in the right mode with the Mikrotron control tool to obtain an image.
I have seen similar issue on a Basler camera on the forum, and it has been solved by using a camera file to set the different parameters. There is no camera file complete to set all the parameters of the camera, so I had to program them in serial to drive the camera with my Labview routine.
Could you help me to solve this issue please?
Thanks
Bests
David DulinThis forum post is already handled --> SR 1154262.
Kind regards,
Corné Westeneng
Applications Engineer
NI-Netherlands -
Bug report: on LabVIEW 2011 SP1 and Windows 8 'Open URL in default browser.vi'
Dear colleagues,
Here is a bug report.
Culprit: 'Open URL in default browser.vi'.
System: Windows 8, Professional. LabVIEW 2011 SP1.
Abnormal behaviour and steps to reproduce:
Above mentioned VI doesn't work when LabVIEW was started with administrator privilegies. And it works as expected when LabVIEW running in normal (non-administrator) mode.
Looking forward to see this fixed.
Best regards,
Igor Titov.
CLD.
=========================
Igor Titov, CLA
WebPager - put LabVIEW front panels into the web page
Labicom.netHi Igor,
Unfortunately LabVIEW 2011 SP1 does not support Windows 8. I tested this behavior with LabVIEW 2012 SP1 on Windows 8 and everything worked correctly.
Regards,
Jeff Peacock
Product Support Engineer | LabVIEW R&D | National Instruments -
Cannot download the Exchange Server 2013 SP1 ISO file from Microsoft Website.
Hello Guys,
I cannot download the Exchange 2013 or Exch 2013 SP1 ISO file from the Microsoft Website.
Before downloading i have register on the Site.
Purpose of downloading the ISO is to upgrade the Active Directory Schema before installing exch server.
We get .exe file instead of ISO.
I am searching it for 2 days now no help.
Suggestion and recommendations highly appreciated.Hi David,
Thanks for the reply...
If we extract .exe file we get .data , .rsrc , .text , .Certificate files by which we cannot upgrade the schema.
As CU7 is available could you please share the link.
So now schema can be update at the time of post installation.
Thanks...!! -
Bug (LabVIEW 2011 sp1 crash)
Bug (LabVIEW 2011 sp1 crash)
1) Open LabVIEW
2) Blank VI
3) Front Panel / View / Class Browser
follow exactly this :
Class Browser / Object library ---> select "LabVIEW Classes" ---> and then clic "Search"
result : The window "Class Browser Search" opens ----> do nothing ... just "Cancel"
back to the window Class Browser ...
Class Browser / Object library ----> now select "DAQmx"
result : in the window Class Browser : Objet library = DAQmx
Class = DAQmx buffer
don't touch anything else (!)
and now clic "Search" ... LV CRASHWhen you meet your colleagues, could you ask them, of course when they have time, to create this number.
This will make me happy, and this would be a small reward for this bug report.
Thank you very much in advance ThiCop -
NI LabVIEW 2013 FPGA Module Xilinx Tools 10.1 Download Troubles
I am trying to download the Xilinx Tools 10.1 to use with a 9113 chassis in LV2011. Based on this white paper the compiler below should work just fine. The problem is I can't get it to download all the way.
I can't seem to get past ~336MB using the standard or NI downloader. Any ideas? Anybody else having this problem?
http://www.ni.com/download/labview-fpga-module-2013/4249/en/
thanks,
-PBD
Solved!
Go to Solution.Well... on the bright side, you don't want 10.1 anyway!
Virtex-5 LX50 <- REQUIRES Xilinx 14.4.
10.1 is only for Virtex-II devices! (...after LabVIEW 2009 that is, just so everyone reading this knows).
soo.... try this link: http://www.ni.com/download/labview-fpga-module-2013/4248/en/
Cheers!
TJ G
Maybe you are looking for
-
Set up Trip Number by Company Code, not Personnel Area
Hi Gurus, I'm implementing Travel Management Module and I am totally new. There are more than 400 Personnel Areas in the system so I'm just wondering whether it is possible to set up trip number rage by Company Code rather than Personnel Areas. Anyon
-
HOW TO KNOW THE TCODE FOR CREATING A NEW ENTRY IN A PARTICULAR TABLE
HI, CAN YOU PLEASE LET ME KNOW THE PROCEDURE TO GET THE TCODE FOR CREATING A NEW ENTITY IN A TABLE . EG: IS THERE ANY PROCEDURE TO KNOW THAT IF I CREATE A NEW ENTITY IN MM01 IT WILL BE STORED IN TABLE MARA. THANKING YOU.
-
Time Capsule vs Seagate for professional video and music
Hi there, I don´t know what to purchase, I want an external hard drive to storage my music and videos as well my photos work, and keep my computer free in space. But if all my documents are in my hard drive, so I wouldn´t backup my documents but only
-
Align to pixel grid frustration
Hello Illustrators. This feature in illustrator I cannot simply turn off/ uncheck you name it, Im even setting a new workspace incase its not checked on again. Im also looking into the preference incase there is a check mark to turn this feature off.
-
Finder not working, when click the infinity sigh comes, can't open any file
finder not working, when click the infinity sigh comes, can't open any file?