Cascading Prompt in User Exit.

Hi Gurus,
I have an enhancement requirement for user exit, but not sure if it could be possibly done. I'll try to make this as explicit as possible. Basically, now I have 2 prompts:
Prompt A - List of Cars
Prompt B - Cars Model
I have been given a requirement to actually filter my selection list of cars based on the cars model. For example, by default List of Cars has 10 Cars before I input anything on the Cars Model. Once I inputted something on Cars Model, my List of Cars should be lesser than 10 Cars (maybe 8 Cars) now due to the unavailability of the Cars based on the Cars Model.
From my understanding, the user exit only will be kick start once the execute button is triggered in RSRT t-code and not on the selection list. So, is it possible to do something like this in user exit?  Let me know if this is still unclear.
Regards,
Kiloh

Hi Bala,
As of I know your requirement is not possible.
If you have city object then it is possible
or
Apply prompt for both country and state with "and"
Regards
Riaz

Similar Messages

  • One Webi Report with multiple Cascade Prompts

    HI
             I have a requirement to create Cascading prompts on WebI reports. I have two questions.
    1) Can one Webi report have two or more sets of Cascading prompts.
    2) The universe is used by several groups of business useres. But only one group needs to have a Cascade prompts. Therefore, if i create Cascading prompts on Universe what is the impact to other business users who dont want the prompts as cascading prompts.
    Please provide me this information.
    Thanks in advance.

    Hi
              Thanks for the repoly. Can you please provide me more information.
    I understand that I need to do following steps.
    1. copy existing universe as universe II.
    2. link Universe II to Universe 1.
    3. Create cascade prompts on Universe II.
    4. Provide access to Business group with the requirement of cascade prompts to Universe II and rest of the groups to Universe I.
    Please let me know if my understanding is right.

  • Best practice on integration message augmentation via user exit or rfc call

    I am looking for documentation that would provide best practices on whether to use user exits to augment the data on an IDOC or to forward the standard SAP produced IDOC to PI where rfc calls are made to augment the data as required for the specific target system.
    I am sure there are pros and cons for both solutions, but I am hesitant to use user exits since we now have moved the knowledge of what a target system wants from the integration layer to the source layer.  If a second target system comes along in the future, the user exit becomes more complicated with additional target specific requirements. 
    Any links to best practice documentation on this subject is greatly appreciated.
    Edited by: Sean Sweeney on Oct 15, 2009 6:59 PM

    Hi Steve,
    Might be trying for solution for a long time, If i understood your question clear let me clarify you few points.
    You are trying to access the bex query which is designed with the exit's in the background based on the logic and trying to call the entire dimensions and key-figures in a single connection. Then you are trying to map those data in the charts.
    Steve, try to make more connections based upon the logic and split them. use the same query but split them by sales per customer group, sales per day, sales per week by making three different connections and try. You can merge the prompts from all connections.
    Hope this Helps!!!
    Sorry if i misunderstood your question.
    --SumanT

  • 0FI_AR_4 Extractor Enhancement without user exit code Question

    Hi
    I have a requirement to enhance 0FI_AR_4 Extractor with below Fields from BSID:
    Field     DataElement
    PRCTR       PRCTR
    VPOS2       NUM06
    VBUND       RASSC
    As per SAP Note: 410799, I am assuming I don't need to write any ABAP code to populate these fields.
    In the extract structure DTFIAR_3 of extractor 0FI_AR_4 Double clicked on the Include CI_BSID.
    It prompted "Structure CI_BSID not available. Create the structure?"
    After entering Access key it created new Structure "CI_BSID".
    I have entered the Component and Component Type values as below:
    Component   Component Type
    YYPRCTR     PRCTR
    YYVPOS2     NUM06
    YYVBUND     RASSC
    1. Please let me know Component and Component Type values and the steps I followed are correct or not?
    2. And I hope I don't need to write the code in the User exit to populate these fields?
    Thanks
    Sree

    Hi,
    For any FI datasource enhancement there are two scenarios :-
    1. All the fields of the customer enhancement in the customer include are available in the read structure BSID
    Then no additional action is required. The fields of the customer enhancement are filled automatically by the datasource from the assigned read structure via "move-corresponding".
    2. Fields of the customer enhancement in the customer include are not contained in the read structure BSID
    In this case you have to program a function module to fill the field of the customer enhancement. To do this, there is a Business Transaction Event available (open FI interface for process 00005021). Create any function module you like and use function module SAMPLE_PROCESS_00005021 as a template for the interface (input parameter, changing parameter).
    Hope this helps.
    Reg,
    Rahul

  • User-Exit/Badi For Vendor Down Payment Request

    hi All,
    Is there any user-exit or badi available for vendor down payment request?
    tcode:f-47.
    please let me know.
    Thanks & Regards,
    Raj

    I want to trigger an event for workflow when
    a vendor down payment request is created in
    *tcode f-47.*
    Well if you are not able to find the correct enhamcement spot then you can approach as below
    When ever you create a New Item In the Tcode F-47 the  if you succesfully saves the data then it prompts you a message like below
    *Document 1700000000 was posted in company code 2100*
    So instead of searching for Exits or BAdi's try to Start workflow by using the message
    for this all you need to bind the message and the Workflow , for this you have use the transaction SWUY it is a wizard where you need to specify the Message class and the message number

  • Problem in transporting the text elements for user exit EXIT_SAPLV09A_002

    Hi  All,
    I am facing a problem in transporting the text element (text symbol) for the exit EXIT_SAPLV09A_002. It is implemented and transported but the text elements are not transported and even if I try to delete them and then create them again, on activation it doesn't prompts for TO and it version its shows it as local object. I have tried to manually assign the TO by using limu as id of program and rept as type and SAPLXV09 as the name of the object but still it doesn't allows as an error message comes prompting local object cannot be assigned to TO. Kindly suggest solution this problem.
    Regards,
    Sachin
    Edited by: Sachin Dangayach on Nov 15, 2010 4:21 PM

    Hello ,
               In the Quality after you run the report check in the layout option>display text elements> variables and check what value is displayed for the use exit variable , if it is correct then problem may be in the selection you gave when you run the report if the user exit variable value is wrong , then set a break point in the code and run the report from rsrt and check where the error is.
    hope it is clear
    assign points if useful

  • How to find user exits for a specific field

    hi,
        How can we find a user exit for a specific fields .
    as i know Three ways to search user-exits
    1. SE80 look includes in a packages with name user-exits
    2.  by zreport which will fetch user-exit in a T-CODE
    3. SMOD
    but what if we have to find a user-exit for particular field for e.g bupla(bussiness place) in MIRO.
    Please suggest me.
    Thanks and  Regards ,
    Rahul Singh.

    Hi Rahul,
    Here is the procedure to create field exits.
    Step by step procedure for creating Field Exits
    There are eight steps to creating a field exit:
    Step 1: Determine Data Element
    Step 2: Go To Field Exit Transaction
    Step 3: Create Field Exit
    Step 4: Create Function Module
    Step 5: Code Function Module
    Step 6: Activate Function Module
    Step 7: Assign Program/Screen
    Step 8: Activate Field Exit
    Step 1: Determine Data Element
    u2022     Before you can begin adding the functionality for a field exit, you must know the corresponding data element.
    Step 2: Go To Field Exit Transaction
    u2022     The transaction to create field exits is CMOD.
    u2022     You can use the menu path Tools -> ABAP/4 Workbench -> Utilities -> Enhancements -> Project management.
    u2022     From the initial screen of transaction CMOD, choose the Text enhancements -> Field exits menu path.
    u2022     After choosing this menu path, you will be taken to the field exits screen. From here, you can create a field exit.
    NOTE : Even though you use transaction CMOD to maintain field exits, you do not need to create a project to activate field exits.
    Step 3: Create Field Exit
    u2022     From the field exit screen of transaction CMOD, choose the Field exit -> Create menu path.
    u2022     After choosing this menu path, a dialog box will prompt you for the appropriate data element .
    u2022     Enter the data element name and click the u2018Continueu2019 pushbutton.
    u2022     Now, you will be able to create the function module associated to the data elementu2019s field exit.
    Step 4: Create Function Module
    u2022     You will automatically be taken to the Function Library (SE37) after entering a data element name and clicking the u2018Continueu2019 pushbutton.
    u2022     In the u2018Function moduleu2019 field, a function module name will be defaulted by the system based on the data element specified. This name will have the following convention:
    FIELD_EXIT_<data element>
    u2022     You can add an identifier (an underscore followed by a single character ).
    u2022     The first function module for a data elementu2019s field exit must be created without an identifier.
    u2022     To create the function module, click on the u2018Createu2019 pushbutton, choose menu path Function module -> Create, or press u2018F5u2019.
    u2022     After choosing to create the function module, you will get the warning: "Function module name is reserved for SAP". This message is just a warning so a developer does not accidentally create a function module in the field exit name range. By pressing u2018Enteru2019, you will be able to go ahead and create the function module.
    u2022     Before coding the function module, you will have to specify the function modules attributes -- function group, application, and short text.
    Step 5: Code Function Module
    u2022     From the function moduleu2019s attributes screen, click on the u2018Source codeu2019 pushbutton or choose the Goto -> Function module menu path to the code of the function module.
    u2022     Here you will add your desired functionality for the field exit.
    u2022     Remember that field exitu2019s function module will have two parameters -- one importing parameter called "INPUT" and one exporting parameter called "OUTPUT". These parameters will be set up automatically by the system.
    u2022     You must remember to assign a value to the OUTPUT field. Even if the value does not change, it must be moved from the INPUT field to the OUTPUT field.
    Step 6: Activate Function Module
    u2022     After coding the function module, you must remember to activate it.
    u2022     Use the Function module -> Activate menu path to activate the function module.
    u2022     At this point, you can return to the field exit transaction.
    u2022     You should be able to 'green arrow' back to this transaction.
    u2022     When you return to the field exit transaction, you will see an entry for the newly created field exit.
    u2022     At this point, the field exit is global. That is, it applies to all screens that use a particular data element. On any screen that uses the data element, the corresponding field exit function module will be triggered, once it is active.
    u2022     Also, the field exit will not be triggered yet because it is inactive.
    Step 7: Assign Program/Screen
    u2022     This step is only needed if you want to make a field exit local.
    u2022     To make a field exit local, select the field exit and click on the u2018Assign prog./screenu2019 pushbutton.
    u2022     In the dialog box , indicate the appropriate program name and screen number.
    This information indicates that the field exit is local to the specified screen in the specified program.
    u2022     In the dialog box, you determine which function module gets executed for the field exit by specifying the identifier in the u2018Fld. Exitu2019 field.
    u2022     If this field is left blank, the function module triggered will be 'FIELD_EXIT_<data element>'.
    u2022     If a single-character identifier is entered into the field, the function module triggered will be 'FIELD_EXIT_<data element>_<identifier>'.
    Step 8: Activate Field Exit
    u2022     The field exit must be active for it to be triggered by the system.
    u2022     Activate the field exit by choosing the Field exit -> Activate menu path.
    u2022     After assigning the field exit to a change request, its status will change to u2018Activeu2019 and it will be triggered automatically on the appropriate screen(s).
    NOTE : In order to activate the field exit the profile parameter abap/fieldexit = YES must be set on all application servers
    Execute the transaction SE38 with PROGRAM NAME - RSMODPRF
    Then give the Data Element Name for which field you want to create the exit(Just cross check with your field data element) and execute.
    then it takes you to SE37 with the function module name FIELD_EXIT_<DATA ELEMENT NAME> and then create the same function module.
    and in the coding part, You can write your logic to display the output of that field. and activate it.
    once you complete the above,
    Again execute SE38 transaction with program RSMODPRF and again click on Execute button without any Data Element Name. Now you select the data element which you have created and click on Assign prog/ Screen button and assign the program name and screen number of the filed and click on the menu Field Exit and Activate.
    Hope it helps.
    Regards
    Radhika
    Edited by: Radhika Pande on Nov 26, 2009 7:58 AM

  • Need help for user exit mereq001

    Hi,
    I need help for user exit mereq001. I think I messed up with include table CI_EBANDB and CI_EBANMEM. And When I tried to check the syntax . It gives me error like : <b>Class IF_PURCHASE_REQUISITION. Inconsistency in the dictionary for the structure mereq_item_s_cust_data.</b> Anyone had experience for this exit? I just need to extract costcenter information of the each item from the requisition and block the requisiton if the costcenter are differents from each other before the requisition is saved. Any one has idea about it?
    Thanks.

    biao,
    Have you checked this struture consistency from SE11. Also check the activation log.
    If there are any errors and you are not able to rectify the same use RSDDCHECK program, give your table name and run the report.
    This will list down the error structures releated this table and also prompts for you to activate it.
    Regds
    Manohar

  • Dynamic Cascading prompt in Webi

    Is there a way either at Webi/Universe level to create dynamic cascading prompt in webi based on selection from first filter object.
    e.g. two objects, Region and Office.
    In webi, Region is the first filter, Office is the second.
    After user selects a Region, I want the second Office prompt values to display only the offices for the region that user's selected.
    Is there is a way to do? or a work round?
    If I just create cascading LOV, it will just display all regions and it's offices together.
    Thanks

    You try the below
    Go to the Office Property.
    Edit the List of Values for the Office object.
    Check the Automatic Refresh Before Use option.
    Click Edit.
    Bring Region into the Conditions and set it to: in list Prompt('What Region?')
    Click Save and Close
    Click Apply and edit the next LOV object.
    Save this Universe and let's generate a report.
    Now in the report you create the Prompt on Region. Prompt('What Region?')
    Have a look in to
    http://homepage.mac.com/rmetzk/PDF_Files/Cascading_Prompts.pdf
    Hope this may help you out.
    Edited by: srrachna on Apr 19, 2011 7:26 AM

  • CR XI Cascading Prompt on Dynamic Parameter Value

    Hi friends need a help related to Cascading prompt parameter in CR XI.
    I need to modify an existing report wherein Stored Procedure having a parameter is used as a datasource. Now in Report when I go in edit mode for that parameter under the value section of it a query (&select col1,col2 from tbl where userid='value coming from front end app') is written which populates the value to select the particluar value to pass as a parameter. First of all what this functionality is termed as I am not aware of it please help me with it if somebody knows it. Also in the select list its mention 2 columns but when we run the report at that time the col2 data is only being displayed in dropdown and col1 which is a id field is passed in record selection formula.
    Now as per our requirement we need to introduce 1 more parameter for record filtering i.e. based on the above parameter value. This can be achieve through Dynamic Cascading Prompt. But the challenge is to use Cascading Prompt funcionality its necessary that both the parent & child field should be populate from db but here the parent value is populate using a query as I stated so in that case how to achieve this.
    Sorry if I am not able to explain the scenario properly.
    Please friends help as soon as possible.

    Looking at the Prompt text you have mentioned, it looks like you guys might have a front end SDK solution which passes the prompt values to the 'Report'. The cascading 'imitation if you will' might be happening on the front end page and not really using the report(s) cascading prompts. To help better i think you should answer following.
    1. where are users viewing this report.
    2. In your CR designer, do you see cascading prompt on existing prompts?
    3. what version of Crystal reports are you using and where is it hosted ?

  • ME31L/ME32L, ME31K/ME32K badi/user exits at item level

    hi all,
    i need to check tax jurisdiction code per item of scheduling agreement and contract.
    coz i need to prompt an error message "tax jurisidation code at line XX is blank" if no tax jurisdiction code is specified.
    can you help me what badi or userexit to use?
    tnx!

    Hi. I'm not aware of any specific user exits or BADI's for contracts, there are lots for purchase orders, and 1 for creating release POs from a contract, but I can't see any spefically for checking contract items.
    However, you could try the custom field exit MM06E005. This would be a bit of a cheat, but it does get called by all purchasing documents including contracts, and all fields are available to check against so you could try and use it just to check the standard fields.
    You can definitly issue errors into the contact from this exit.
    Regards,
    Dave.

  • Cascading Prompts in Crystal from a Universe

    Hi There,
    How can I create a cascading prompt on the Universe to be used in crystal?
    I have created a Cascading prompt in the Universe and it work in Webi but for some reason you do not see the cascading LOV
    Versions BOE XI 3.1 SP2 FP2.4 Crystal Reports 2008 v1 SP2.
    Regards,

    Hi Abhilash,
    Thanks for replying ...
    The same report is working fine on windows server 2008 R2 and IE 8.0.7601 . Can you pleasde guide through which pack should i install on BO server to overcome this issue . As all my users are using IE 9 version only .
    Thanks,
    Sahana

  • BEX User exit variables in WEBI

    Hi Experts,
    Need your help please.
    I have a report in BEX with a user exit variable wich depends on other manual input variable.
    In BEX it works properly but in WEBI it doesn't recognize the user exit variable.
    It displays the error message: Not possible to determine the value for ZPD_YEAR_DAY variable
    Error in DB.​ ​Error message is​:​ ​failure to execute the query ​M​D​X​ ​S​E​L​E​C​T​ ​ ​{​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​C​S​1​W​7​F​A​8​F​E​O​H​J​3​T​3​2​H​4​Q​D​Z​4​]​,​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​D​H​9​K​1​N​I​T​C​Z​E​4​U​Y​3​J​4​U​A​E​T​Z​4​]​,​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​D​H​9​K​1​N​I​T​D​R​2​R​6​P​F​2​K​G​C​U​8​8​W​]​,​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​C​S​1​W​7​F​A​8​E​M​Z​V​7​C​H​J​M​V​2​A​Z​P​C​]​,​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​C​S​1​W​7​F​A​8​K​0​S​7​H​N​Q​B​O​5​J​A​R​L​S​]​,​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​C​S​1​W​7​F​A​8​G​6​D​3​U​V​4​M​I​3​7​5​S​8​W​]​,​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​C​S​1​W​7​F​A​8​H​P​Q​C​I​D​R​P​D​B​C​0​K​S​G​]​,​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​C​S​1​W​7​F​A​8​I​H​E​Y​U​5​3​8​S​X​E​F​Z​2​8​]​,​ ​[​M​e​a​s​u​r​e​s​]​.​[​D​9​D​H​2​8​D​W​V​F​6​7​4​2​E​6​4​Z​O​L​8​F​X​3​4​]​ ​}​ ​ ​O​N​ ​C​O​L​U​M​N​S​ ​,​ ​N​O​N​ ​E​M​P​T​Y​ ​C​R​O​S​S​J​O​I​N​(​ ​C​R​O​S​S​J​O​I​N​(​ ​C​R​O​S​S​J​O​I​N​(​ ​C​R​O​S​S​J​O​I​N​(​ ​C​R​O​S​S​J​O​I​N​(​ ​C​R​O​S​S​J​O​I​N​(​ ​C​R​O​S​S​J​O​I​N​(​ ​C​R​O​S​S​J​O​I​N​(​ ​C​R​O​S​S​J​O​I​N​(​ ​ ​{​ ​[​0​C​A​L​Y​E​A​R​]​.​[​2​0​1​0​]​ ​}​ ​,​ ​ ​{​ ​[​0​H​A​P​_​D​O​C​_​I​D​_​_​Z​A​P​_​S​U​B​S​T​]​.​[​5​0​]​,​ ​[​0​H​A​P​_​D​O​C​_​I​D​_​_​Z​A​P​_​S​U​B​S​T​]​.​[​7​0​]​ ​}​ ​ ​)​,​ ​[​0​I​N​F​O​P​R​O​V​]​.​[​L​E​V​E​L​0​1​]​.​M​E​M​B​E​R​S​ ​)​,​ ​[​Z​D​A​T​E​_​A​T​]​.​[​L​E​V​E​L​0​1​]​.​M​E​M​B​E​R​S​ ​)​,​ ​ ​{​ ​[​Z​C​P​M​]​.​[​X​]​ ​}​ ​ ​)​,​ ​[​Z​P​R​O​M​O​C​A​O​]​.​[​L​E​V​E​L​0​1​]​.​M​E​M​B​E​R​S​ ​)​,​ ​[​Z​R​E​S​P​_​A​V​L​_​_​Z​N​I​V​_​C​A​R​R​]​.​[​L​E​V​E​L​0​1​]​.​M​E​M​B​E​R​S​ ​)​,​ ​[​Z​R​E​S​P​_​A​V​L​]​.​[​L​E​V​E​L​0​1​]​.​M​E​M​B​E​R​S​ ​)​,​ ​[​Z​N​I​V​_​C​A​R​R​]​.​[​L​E​V​E​L​0​1​]​.​M​E​M​B​E​R​S​ ​)​,​ ​[​0​E​M​P​L​O​Y​E​E​]​.​[​L​E​V​E​L​0​1​]​.​M​E​M​B​E​R​S​ ​)​ ​D​I​M​E​N​S​I​O​N​ ​P​R​O​P​E​R​T​I​E​S​ ​M​E​M​B​E​R​_​N​A​M​E​,​ ​M​E​M​B​E​R​_​C​A​P​T​I​O​N​,​ ​[​0​E​M​P​L​O​Y​E​E​]​.​[​2​0​E​M​P​L​O​Y​E​E​]​,​ ​[​0​E​M​P​L​O​Y​E​E​]​.​[​4​0​E​M​P​L​O​Y​E​E​]​,​ ​[​0​H​A​P​_​D​O​C​_​I​D​_​_​Z​A​P​_​S​U​B​S​T​]​.​[​2​0​H​A​P​_​D​O​C​_​I​D​_​_​Z​A​P​_​S​U​B​S​T​]​,​ ​[​Z​R​E​S​P​_​A​V​L​]​.​[​2​Z​R​E​S​P​_​A​V​L​]​ ​O​N​ ​R​O​W​S​ ​F​R​O​M​ ​[​Z​A​V​D​P​_​M​0​1​/​Z​P​D​_​G​P​S​_​V​A​R​I​A​V​E​L​_​0​0​2​]​ ​ ​with error:​ Not possible to determine the value for ZPD_YEAR_DAY variable​.​ ​(​W​I​S​ ​1​0​9​0​1​)
    This ZPD_YEAR_DAY variable​ is the user exit variable.
    Thanks in advance,
    José Simões

    Hi!
    I am following up to this post to see if there is something I am missing.
    We have bex query with user exit variable and webi bi4sp04.4
    In bex the user exit variable works correctly, in webi, it is ignored  (the webi results are not filtered as they are in bex web results)
    I have tried moving the variable to the char restrictions and removed ready for input - so there are now no prompts in bex query.
    I have reviewed note 1611185 as well as other info on restrictions of BICS and webi, but cannot find a clear answer if bex user exit variables are supported in BI4 clients or not.
    Lee Lewis

  • Dynamic Cascading Prompt based on Universe

    Hi,
    I am attempting to build a universe-query-based report which allows the user to select inputs based on a dynamic cascading prompt. I have created the cascading LOVs in the Universe design. However, when the user is asked to select inputs, the prompts do not appear to cascade. They show all possible values independent of each input(there are 3 inputs). When I try to manually create the dynamic cascading prompt on the actual report, I select dynamic parameter but it does not show any values under the Choose Data Source option. All it shows is "(None)". Any suggestions on how I can get this cascading prompt to work? I am using CR 2008 also.
    Thanks for you help!
    David

    Hey David,
    Steps to create connection in Business View Manager:
    1) Go to Start -> Program files > Business objects xir2> business objects enterprise > businessview manager.
    2) Click on New >
    3) Steps to create is Create a Data connection > Select Data Connection > Data sources > Save the data foundation.
    4) Second is to create a data foundation.
    Click New > Data foundation > Select the Data Connection and Select the Table.
    5) Third is to create a data element.
    Click New >Data Element > Select the Data Foundation Select the required fields for Lov from the table.
    6) Is to create a business view > New > Business View >select the data element > save the business view.
    7) Is to create a Lov> New > LOV > Select the business view > Select the fields for dynamic cascading parameter fields and save the LOV
    8) Open the crystal report designer > connect to the repository > create a new parameter > select dynamic> Select Existing > Select the LOV created through the business view manager.
    Note : Should Save all the Connection, data Foundation, business elements, business view and LOV separately and instantly.
    Let me know if any.
    Regards,
    Naveen.

  • Web Intelligence Cascading Prompts

    Hi all,
    I have a question about Web Intelligence, I am building a webi query over the top of a Bex query, so using a BICS connection. The customer wants to user cascading Query prompts, so basically if the user selects Italy as a country only the products sold in Italy will be displayed as possible selections in a product query prompt. Does anyone know how to do this? I have looked at the ‘Result from another Query’ option where we could have chained two queries together, however this option is not available in a BICS connection.
    Any help is gratefully appreciated.
    Thanks
    Dave

    Getting data from another query is not an option with the BICS based webi.Also unfortunately there is no good way to have a custom cascading prompt if the hierarchies are not available in Bex. Here is a link to the idea place to have this functionality in a future release https://ideas.sap.com/ct/ct_a_view_idea.bix?c=7732DE74-E9A6-4736-AEE0-6181E5BB5F5E&idea_id=EE6432C0-BC6C-47E6-BB04-C095B3C398B8 However if performance is not an issue and you need this functionality you might also want to look at MDX based OLAP universe using the old UDT tool which is still available with BI 4.0 . That will allow the custom cascading prompt  to be created on the universe.

Maybe you are looking for

  • How to change the JCO reference of an existing model  in CE 7.1

    Hi All I have read an article which explains the method to change the JCO reference of model but when I tried to follow the same steps in CE 7.1 i am not able to find the category "Model Settings" (on clicking model edit option) containing the proper

  • IWEB help for a newbie

    I have a few questions, I recently switched to apple and I love it I am use to front page so I am learning.........I have made a site and I got it to upload to an appache server at 1st host web......I needed to make a few changes and i opened iweb an

  • Shipping in shipping point from plant and storage location is not possible

    Dear Experts, i am trying to configure STO with delivery scenario in my company after creating PO (sto UB) and delivery through vl10b when i try to do picking in vl02n and when i enter storage location its giving error "shipping in shipping pointxx f

  • Tcode to find all Tcode access by user

    What is TCODE to find all the Tcode executed by perticular user in last 24 hrs I try ST03 but i didnt get desired result Plz help

  • Need Information for transporting a file as IDOC through File Port!!!

    Hi, All configurations are present in the system to transfer a file as IDOC using File Port. Now we are creating a custom program to transfer the same. Now i have all the data in an internal table which has to be send to Non SAP system. So can i know