Catalyst 6500 IPv6 scalability

Hi,
There is an issue on Cat6500 (SUP720-3B) with a lot of IPv6 SVIs: %FM-4-TCAM_LABEL: Hardware TCAM label capacity exceeded.
#sh tcam counts ipv6
           Used        Free        Reserved
Labels:(in) 512           0
Labels:(eg) 59         453
Each IPv6 SVI consumes one label.
#show platform software ipv6-multicast capability | include entries
Directly-connected entries for IPv6 is supported using ACL-TCAM.
#show platform software ipv6-multicast connected
IPv6 Multicast Subnet entries
Flags : H - Installed in ACL-TCAM
        X - Not installed in ACL-TCAM due to
            label-full exception
Interface: Vlan3733 [ H ]
  S:0:2001:4860:241:B100::1 G:FF00::
  S:2001:4860:241:B100::1 G:FF00::
Interface: Vlan3732 [ H ]
<output omitted>
Is it possible to increase amount of this labels or solve the problem somehow else?

The IDSM-2 module is capable of both IDS (promiscuous mode) AND IPS (inline mode).
So if you need IPS (inline mode) you still just buy the same IDSM-2 but configure it for InLine Interface Pair or InLine Vlan Pair mode instead of configuring for Promiscuous mode.

Similar Messages

  • Cisco Catalyst 6500 version 12.2(33)SXI13 configured as DHCP server for a VLAN responds to Windows 7 client with status code NOA

    Can anyone help figure out why the Catalyst 6509 is not able to assign an IPv6 address? Thank you.
    Cisco Catalyst 6500 version 12.2(33)SXI13 configured as DHCP server for a VLAN responds to Windows 7 client with status code NOADDRS-AVAIL(2). My configuration on the 6500 for the DHCPv6 server is:
    ipv6 dhcp database disk0://DHCPV6-DB
    ipv6 dhcp pool VLAN206IPV6
     prefix-delegation pool VLAN206IPV6-POOL
     dns-server 2620:B700:0:1001::53
     domain-name global.bio.com
    ipv6 local pool VLAN206IPV6-POOL 2620:B700:0:12C7::/65 65
    interface Vlan206
     description *** IPv6 Subnet ***  
     ip address 10.2.104.2 255.255.255.0
     ipv6 address 2620:B700:0:12C7::2/64
     ipv6 nd prefix 2620:B700:0:12C7::/64 14400 14400 no-autoconfig
     ipv6 nd managed-config-flag
     ipv6 dhcp server VLAN206IPV6
     standby version 2
     standby 0 ip 10.2.104.1
     standby 0 preempt
     standby 6 ipv6 2620:B700:0:12C7::1/64
     standby 6 preempt
    I'm getting a result from my debug as follows:
    Apr 10 16:28:02.873 PDT: %LINK-3-UPDOWN: Interface GigabitEthernet2/2, changed state to up
    Apr 10 16:28:02.873 PDT: %LINK-SP-3-UPDOWN: Interface GigabitEthernet2/2, changed state to up
    Apr 10 16:28:02.877 PDT: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/2, changed state to up
    Apr 10 16:28:03.861 PDT: IPv6 DHCP: Received SOLICIT from FE80::5D5E:7EBD:CDBF:2519 on Vlan206
    Apr 10 16:28:03.861 PDT: IPv6 DHCP: detailed packet contents
    Apr 10 16:28:03.861 PDT:   src FE80::5D5E:7EBD:CDBF:2519 (Vlan206)
    Apr 10 16:28:03.861 PDT:   dst FF02::1:2
    Apr 10 16:28:03.861 PDT:   type SOLICIT(1), xid 8277025
    Apr 10 16:28:03.861 PDT:   option ELAPSED-TIME(8), len 2
    Apr 10 16:28:03.861 PDT:     elapsed-time 101
    Apr 10 16:28:03.861 PDT:   option CLIENTID(1), len 14
    Apr 10 16:28:03.861 PDT:     00010001195FD895F01FAF10689E
    Apr 10 16:28:03.861 PDT:   option IA-NA(3), len 12
    Apr 10 16:28:03.861 PDT:     IAID 0x0FF01FAF, T1 0, T2 0
    Apr 10 16:28:03.861 PDT:   option UNKNOWN(39), len 32
    Apr 10 16:28:03.861 PDT:   option VENDOR-CLASS(16), len 14
    Apr 10 16:28:03.861 PDT:   option ORO(6), len 8
    Apr 10 16:28:03.861 PDT:     DOMAIN-LIST,DNS-SERVERS,VENDOR-OPTS,UNKNOWN
    Apr 10 16:28:03.861 PDT: IPv6 DHCP: Option IA-NA(3) is not supported yet
    Apr 10 16:28:03.861 PDT: IPv6 DHCP: Sending ADVERTISE to FE80::5D5E:7EBD:CDBF:2519 on Vlan206
    Apr 10 16:28:03.861 PDT: IPv6 DHCP: detailed packet contents
    Apr 10 16:28:03.861 PDT:   src FE80::21D:E6FF:FEE4:4400
    Apr 10 16:28:03.861 PDT:   dst FE80::5D5E:7EBD:CDBF:2519 (Vlan206)
    Apr 10 16:28:03.861 PDT:   type ADVERTISE(2), xid 8277025
    Apr 10 16:28:03.861 PDT:   option SERVERID(2), len 10
    Apr 10 16:28:03.865 PDT:     00030001001DE6E44400
    Apr 10 16:28:03.865 PDT:   option CLIENTID(1), len 14
    Apr 10 16:28:03.865 PDT:     00010001195FD895F01FAF10689E
    Apr 10 16:28:03.865 PDT:   option STATUS-CODE(13), len 15
    Apr 10 16:28:03.865 PDT:     status code NOADDRS-AVAIL(2)
    Apr 10 16:28:03.865 PDT:     status message: NOADDRS-AVAIL

    Hello,
    maybe hitting the following bug.
    Pv6 Address Assignment Support for IPv6 DHCP Server
    CSCse81385
    Hope this helps

  • How to remove the WiSM2 from the Catalyst 6500 series switch?

    Hello, can you explain to me how to safely remove the WiSM2 from the Catalyst 6500 series switch?
    According to the documentation "Catalyst 6500 Series Wireless Services Module 2 Installation and Verification Note":
    To remove the WiSM2, perform these steps:
    Step1     Shut down the module by one of these methods:
    In privileged mode from the router prompt, enter the hw-mod module mod shutdown command. NoteIf you enter this command to shut down the module, you must enter the following commands in global configuration mode to restart (power down, and then power up) the module:
    Router# no power enable module modRouter# power enable module mod
    If the module does not respond to any commands, press the SHUTDOWN button located on the front panel of the module.
    Step2     Verify that the WiSM2 shuts down. Do not remove the module from the switch until the POWER LEDis off.
    But, in the case of Step1 (1st methods) I do not see a option "shutdown"  in the command "hw-mod module 3"...
    All I prompted to enter is:
    c6500#hw-module module 3 ?
    boot           Specify boot options for the module through Power Management Bus control register
    reset          Reset specified component
    simulate  Simulate options for the module
    Is it hidden options? IOS version of c6500 is 12.2(33)SXJ1
    In the case of Step2 (2nd methods) there is not any button on the front panel of the module?
    And yet, it is better to remove the module configuration manually or use the command module clear-config prior to removing the module?

    Good catch.
    Which one is true, will get back to you on this if i've something soon.
    http://www.cisco.com/en/US/docs/wireless/module/wism2/installation/note/WiSM_2.html#wp34727
    The above link is procedure to remove wism2. This procedure doesn’t look like wism2 is hot swapable.
    http://www.cisco.com/en/US/docs/wireless/module/wism2/installation/note/WiSM_2.html#wp34621
    All modules, including the supervisor engine (if you have redundant supervisor engines), support hot swapping. You can add, replace, or remove modules without interrupting the system power or causing other software or interfaces to shut down. For more information about hot-swapping modules, see the Catalyst 6500 Series Switch Module Installation Guide.

  • Connection of LC/APC fiber patch cords to Cisco Catalyst 6500 $ Cisco Access 3750 Switches

    I have an LC/APC fiber patch cord infrastructure and I want to connect it to Cisco Catalyst 6500 & Cisco Access 3750 Switches. what type of transceiver should be used?
    I read a note on Cisco website stating the following for Cisco SFP+ transceivers:
    Note: "Only connections with patch cords with PC or UPC connectors are supported. Patch cords with APC connectors are not supported. All cables and cable assemblies used must be compliant with the standards specified in the standards section"

    Thank you,  but my question is that I have a single mode fiber patch cord with LC/APC connector while cisco stating a note that only use LC/PC or LC/UPC type of connectors with SFP+ transceiver.  
    So what type of transceiver should I use to connect LC/APC patch cord to cisco switches?  Is there another type or SFP+ still can be used? 

  • Configuring the Catalyst 6500 Switch for IPS Inline Operation of the IDSM

    I understand how to configure the Catalyst 6500 switch so that the monitoring ports are access ports in two separate VLAN's for inline operation.
    However, I don't see any documentation that describes how the desired VLAN traffic gets forced through the IPS.
    In promiscuous mode, you can use VACL's to copy/capture and forward the desired traffic to the IDSM for analysis. I'm not seeing how to get the desired traffic through the IPS.
    Note that the host 6500 is running native IOS 12.2(18)SXE.
    Thanks for any assistance.

    A tranparent firewall is a fairly good comparison.
    Let's say you have vlan 10 with 100 PCs and 1 Router for the network.
    If you want to apply a transparent firewall on that vlan you can not simply put one interface of the firewall on vlan 10. Nothing would go through the firewall.
    Instead you have to create a new vlan, let's say 1010. Now you place one interface of the firewall on vlan 10 and the other on vlan 1010. Still nothing is going through the firewall. So now you move that Router from vlan 10 to vlan 1010. All you do is change the vlan, the IP Address and netmask of the router stay the same.
    The transparent firewall bridges vlan 10 and vlan 1010. The PCs on vlan 10 ae still able to communicate to and through the router, but must go through the transparent firewall to do so.
    The firewall is transparent because it does not IP Route between 2 vlans, instead the same IP subnet exists on both vlans and the firewall transparently beidges traffic between the 2 vlans.
    The transparent firewall can do firewalling between the PCs on vlan 10 and the Router on vlan 1010. But is PC A on vlan 10 talks to PC B on vlan 10, then the transparent firewall does not see and can not block that traffic.
    An InLine sensor is very similar to the transparent firewall and will bridge between the 2 vlans. And similarly an InLine sensor is able to InLine monitor traffic between PCs on vlan 10 and the Router on vlan 1010, but will not be able to monitor traffic between 2 PCs on vlan 10.
    Now the router on one vlan and the PCs on the other vlan is a typical deployment for inline sensors, but your vlans do not Have to be divided that way. You could choose to place some servers in one vlan, and desktop PCs in the other vlan. You subdivide the vlans in what ever method makes sense for your deployment.
    Now for monitoring multiple vlans the same principle still applies. You can't monitor traffic between machines on the same vlan. So for each of the vlans you want to monitor you will need to create a new vlan and split the machines between the 2 vlans.
    In your case with Native IOS you are limited to only 1 pair of vlans for InLine monitoring, but your desired deployment would require 20 vlan pairs.
    The 5.1 IPS software has now the capability to handle the 20 pairs, but the Native IOS software does not have the capability to send the 40 vlans (20 pairs) to the IDSM-2.
    The Native IOS changes are in testing right now, but I have not heard a release date for those changes.
    Now Cat OS has already made these changes. So here is a basic breakdown of what you could do in Cat OS and you can use in preparation for a Native IOS deployment when it gets released.
    For vlans 10-20, and 300-310 that you want monitored you will need to break each of those vlans in to 2 vlans.
    Let's say we make it simple and add 500 to each vlan in order to create the new vlan for each pair.
    So you have the following pairs:
    10/510, 11/511, 12/512, etc...
    300/800, 301/801, 302/802, etc....
    You set up the sensor port to trunk all 40 vlans:
    set trunk 5/7 10-20,300-310,510-520,800-810
    (Then clear all other vlans off that trunk to keep things clean)
    In the IDSM-2 configuration create the 20 inline vlan pairs on interface GigabitEthernet0/7
    Nw on each of the 20 original vlans move the default router for each vlan from the original vlan to the 500+ vlan.
    At this point you should ordinarily be good to go. The IDSM-2 won't be monitoring traffic that stays within each of the original 20 vlans, but Would monitor traffic getting routed in and out of each of the 20 vlans.
    Because of a switch bug you may have to have an additional PC moved to the same vlan as the router if the switch/MSFC is being used as the router and you are deploying with an IDSM-2.

  • Hi, I have a Catalyst 6500 with X6K-SUP2-2ge, the IOS and bootlader image been wiped out, it starts in ROMmon SP mod end can't switch to RP to start download the IOS using Xmodem, though it shouldn't work in ROMmon SP omde but the xmodem is not gving the

    Hi, I have a Catalyst 6500 with X6K-SUP2-2ge, the IOS and bootlader image been wiped out, it starts in ROMmon SP modw and I can't switch to RP to start download the IOS using Xmodem, though Xmodem shouldn't work in ROMmon SP mode but the it's not gving the
    not executable message, the slot0: and disk0: are not accessable can't see the files inside, when I try the dir slot0: or dir disk0: it says it can't be opened and when I try to boot from them there's noting as well, what can I do to load an IOS image to the booflash: or slot0: ,each time I load the image using Xmodem at the end it gives me *** System received a Software forced crash ***
    signal=0x17, code=0x5, context=0x0
    When I run the command:
    rommom1> boot bootflash:
    boot: cannot determine first file name on deice "bootflash:"
    rommon2> boot slot0:
    boot: cannot open "slot0:"
    boot: cannot dtermine first file name on device "slot0:"
    BTW  System Bootstrap, version 7.1
    I''m looking to format the PCMCIA using a PC and format it to FAT16 and copy the boot image into it and then try to load from the PCMCIA afterward if it works I'll format it using the Supervisor engine 2.
    Any one have another new idea I can use, thanks in advance

    This is a potentially complex issue.
    Is this SUP configured to run as IOS native or CatOS Hybrid?
    While in ROMMON can you do the 'dev' command and see whad drives are recognized. Then 'dir' the drives that the SUP recognizes.
    Can you provide the screen captures as it boots?
    You would be bette served by hacing a TAC case.

  • Installing New network card on a Cisco Catalyst 6500 VSS mode

    Hi All.
    I need to install a new network card on Cisco Catalyst 6500 VSS mode, I need to follow any special procedures or is it only insert the new card and the Catalyst automatically recognizes the card?
    Thank you So mucho. 

    Hi,
    Just insert the blade and the switch should recognize it. For the 6500 series the blades are hot swap able.
    HTH

  • Modules Gbic Catalyst 6500

    I have a peculiar problem with two gbic modules of Catalyst 6500.
    First problem, I have a gbic port in module 7, which was a trunkport to Catalyst 2950, that does not allow conection to switch Catalyst 2950, and besides it harmed the yield of Catalyst 6500. I have to disconnect the optical fiber cable so that everything returned to normality.
    Second problem. A port gbic in module 8, I let work and I disconnect of the network to one of the servants, by such reason I had to connect the fiber cable in another one gbic of he himself I module.
    My question is: is necessary to change I modulate 7 and 8 not to have network problems on watch? or single to change gbic affected in each one of the modules?
    Thank you,

    Failure to get GBIC up during installation could be as a result of system requirements not met, incorrect cable installed, lack of power to the device, configuration errors or hardware failure. Verify that the GBIC cable is connected to another active network device and that the port is not shut down. Replace cable with a known good cable. Make sure GBICs are matched on either side of the connection. Make sure the flow control and port negotiation settings are consistent on both sides of the link. There may be incompatibilities in the implementation of these features if the switches being connected are from different vendors. If in doubt, turn these features off on both switches. Swap GBIC to a different slot. Also, try using a spare GBIC to see if it works. For more information, refer to Troubleshooting link :
    http://www.cisco.com/en/US/products/hw/switches/ps628/products_installation_guide_chapter09186a00800d7681.html

  • IDSM on catalyst 6500 to provide IOS Inline mode support

    I am currently evaluating what kind of method to apply in my 6500. I would like to ask if IOS Version 12.2(33)SXI2a  support inline mode and inline vlan pair mode with IDSM-2???what configuration should be done with the switch in order for the multiple vlan traffic to flow with an inline interface of the IDSM2??? In my case I have 16 user vlans and 1 server vlan on catalyst 6500...The task is to protect the servers from users....The requirement is to configure inline mode to monitor the traffic from these 16 vlans when they access the servers...But as we know the IDSM-2 has only two logical sensing ports...So my question is how will you configure the switch to forward the traffic from these 16 vlans to the IDSM-2 module via only ONE sensing port, since the other sensing port will be configured in the server vlan???  Because as far as i know, when you configure inline mode on IOS,you will have to configure the sensing ports in access mode( While in CatOS, you configure these as TRUNK ports)...But this will work when you have only two vlans...But in my case, I have 16 vlans to monitor in inline mode..Please suggest any solution.
    Any urgent reply will be much grateful...
    Many Thanks in advance

    Hi Mubin,
       If you're looking to monitor all the traffic from the user VLANs to the server VLANs then the simplest way to configure the IDSM-2 would be inline on the server VLAN segment.  All traffic destined to the servers (from the users or anywhere else) has to traverse that VLAN.  Assuming you have something like this to start:
    VLAN 100-120 (users) ====== Switch ------ VLAN 200 (servers)
    you'd drop the IDSM-2 inline on VLAN 200 by using a helper VLAN:
    VLAN 100-120 (users) ====== Switch ----- VLAN 201 (server gateway) ----- IDSM-2 (bridging 201 to 200) ----- VLAN 200 (servers)
    To do this you'll need to perform the following steps:
    1.  Designate a new VLAN to use as a helper VLAN for your current server VLAN.  I'll use 201 for this example and assume your current server VLAN is 200.
    Create the helper VLAN on the switch:
    switch# conf t
    switch(config)# vlan 201
    2.  Configure the IDSM-2 to bridge the helper VLAN and the server VLAN (200-201)
    sensor# conf t
    sensor(config)# service interface
    sensor(config-int)# phsyical-interface GigabitEthernet0/7
    sensor(config-int-phy)# admin-state enabled
    sensor(config-int-phy)# subinterface-type inline-vlan-pair
    sensor(config-int-phy-inl)# subinterface 1
    sensor(config-int-phy-inl-sub)# vlan1 200
    sensor(config-int-phy-inl-sub)# vlan2 201
    sensor(config-int-phy-inl-sub)# description Server-Helper pair
    sensor(config-int-phy-inl-sub)# exit
    sensor(config-int-phy-inl)# exit
    sensor(config-int-phy)# exit
    sensor(config-int)# exit
    Apply Changes:?[yes]:
    3.  Configure the switch to trunk the helper and server VLANs to the IDSM-2 module.  I assume the module is in slot 5 in the example.  Replace the 5 with the correct slot for your deployment:
    switch# conf t
    switch(config)# intrusion-detection module 5 data-port 1 trunk allowed-vlan 200,201
    switch(config)# intrusion-detection module 5 data-port 1 autostate include
    *Warning! This next step may cause an outage if everything is configured correctly.  You'll probably want to schedule a window to do this.*
    4.  Finally, force the traffic from the server VLAN through the IDSM-2 by moving the server VLAN gateway from VLAN 200 (where it is currently) to the helper VLAN you created.  To do this, remove the SVI from VLAN 200 and apply the same IP address to VLAN 201.  I assume the current server gateway is 192.168.1.1/24
    switch# conf t
    switch(config)#int vlan 200
    switch(config-int)#no ip addr
    switch(config-int)#int vlan 201
    switch(config-int)#ip addr 192.168.1.1 255.255.255.0
    switch(config-int)#exit
    switch(config)#exit
    switch# wr mem
    Now, when the servers try to contact 192.168.1.1 (their gateway) they'll have to be bridged through the IDSM-2 to reach VLAN 201 and in the process all traffic destined to them or sourced from them will be inspected.  Do not put any hosts or servers in the helper VLAN (201) or they will not be inspected.
    Best Regards,
    Justin

  • Firewalling vlans on Catalyst 6500 by using Cisco ASA Firewalls

    Hello,
    How to secure vlans on Catalyst 6500 by using Cisco ASA Firewalls?
    There are no free modules on Catalyst 6500 to install a FWSM module.
    What is the best configuration to secure vlans (~80 vlans) by using cisco ASA firewalls (context, hairpining...)?
    Thanks

    Hi Bro
    Just to understand your question once again, you don't have anymore available slots in your present Cat6K, but you want to know how to secure your VLANs or SVIs that has been configured in your Cat6K?
    If you were to ask me, I would not apply a bunch of ACLs in the Cat6K, for starters. You might wanna look into COPP (Control Plane Policing) instead. Furthermore you could also refer to this Cisco document http://www.cisco.com/en/US/products/hw/switches/ps708/products_white_paper09186a00801b49a4.shtml
    However, if you do have Cisco ASA FW appliance (not module, I presume from your question), you could enable ACLs, threat-detection feature, IP Audit features, reverse-path policing, capping of the embryonic values etc.
    P/S: If you think this comment is useful, please do rate them nicely :-)

  • Replacement catalyst 6500 switches under redundancy environment

    Hi everyone,
    I plan to replace old core catalyst 6500 switches with new ones for the purpose of reinforcement.
    Now two core catalyst 6500 switches are working under redundancy environment.
    There are many catalyst 6500 switches as distribution switch connect to each core catalyst
    6500 switches as attached.
    I think there are two ways to replace core catalyst 6500 switches.
    [One]
    Replacing one core catalyst 6500 switches first, then one week later, replacing another core
    catalyst 6500 switch. And all traffic will be handled another core catalyst 6500 switch automatically
    by EIGRP routing during replacement.
    Advantage:
    One another core catalyst 6500 switch continues operating even if the replacement fail.
    Disadvantage:
    Two core catalyst 6500 switches will operate in a different version (CatOS, MSFC IOS) for one week.
    Any problem might be happened due to this issue.
    [Two]
    Replacing both core catalyst 6500 switches at the same time.
    Advantage:
    Replacement will be finished at one time
    Disadvantage:
    If the replacement fail, whole network goes to down and it cause critical situation.
    I have to replace successfully so I would like know good information about this, such as
    best practice, case study and so on.
    Your information would be greatly appreciated.
    Best regards,

    Hi,
    If I were you, I will go for option 1.
    This option will give us the time to observe the traffic pattern, time to get the network and EIGRP to stabilize and even to check for any issues on the IOS part.
    This will give you time frame to work out for any issue if it happens in between the weeks time.This will gibe you tha time to see for any imcompatibilty issues as such.
    HTH, Please rate if it does.
    -amit singh

  • 15.1(2)SY1 on Catalyst 6500

    Hi,
    We are planning to upgrade two of our Catalyst 6500 switches to version 15.1(2)SY1 Advanced IP Services.
    The switches have dual supervisors and are currently running version 12.2(33)SXI11, but we have faced some issues and also would also like to enable some new features (e.g. BFD). The switches are running a fairly simple configuration with OSPF, MPLS and MP-BGP with about 30 VRFs.
    Are you aware of any major issues with 15.1(2)SY1 and would discourage the planned upgrade? I am aware that the version was only released in December, but since there are many bug fixes I thought this version might be better than e.g. 15.1(2)SY.
    Thanks in advance for your help!
    Best regards,
    Harry

    We replaced all (~ x20) our Sup720 (SXI4a) with Sup2T during late 2012 & running with Advance Enterprise 15.0(1)SY image. We did not have any issues with that code & still many of our distribution switches running on that code.
    Then we upgraded two core switches with 15.1(1)SY mid last year another two core switches to 15.1(2)SY late last year to accomodate WS-X6904-40G. With both of these new code we had couple of bugs still not proper fix
    CSCue58955: sup2t: LC file systems are not destroyed in Active upon reset"%SNMP-3-INPUT_QFULL_ERR: Packet dropped
    There is workaround for this, but that will impact netflow data if you are using that.
    For me 15.0(1)SY, is much better for Enterprise environment (based on my experience) compare to the two latest. But due to certain limitation we have to go for this newer codes whether you like it or not.
    These bugs may be not related to you if you are not runing Sup2T, anyway just thought to share this experience
    HTH
    Rasika
    **** Pls rate all useful responses ****

  • Catalyst 6500 with CatOS ISCSI

    Hi, I'm configuring a Catalyst 6500 with for ISCSI.
    Following the recommendations I have to configure: portfast, jumbo frames, flow control and disable unicast storm control
    - Portfast: on the server and ISCSI SAN ports
        >
    /* Style Definitions */
    table.MsoNormalTable
    {mso-style-name:"Tabla normal";
    mso-tstyle-rowband-size:0;
    mso-tstyle-colband-size:0;
    mso-style-noshow:yes;
    mso-style-priority:99;
    mso-style-qformat:yes;
    mso-style-parent:"";
    mso-padding-alt:0cm 5.4pt 0cm 5.4pt;
    mso-para-margin-top:0cm;
    mso-para-margin-right:0cm;
    mso-para-margin-bottom:10.0pt;
    mso-para-margin-left:0cm;
    line-height:115%;
    mso-pagination:widow-orphan;
    font-size:11.0pt;
    font-family:"Calibri","sans-serif";
    mso-ascii-font-family:Calibri;
    mso-ascii-theme-font:minor-latin;
    mso-fareast-font-family:"Times New Roman";
    mso-fareast-theme-font:minor-fareast;
    mso-hansi-font-family:Calibri;
    mso-hansi-theme-font:minor-latin;}
    set spantree portfast
    - Jumbo frames: Set port jumbo
    - Flow Control:
         > set port flow control receive desired
    Questions:
    1. Where I have to configure flow control? only on the SAN ports and NIC servers? or server ports too?
    2. Unicast Storm control: how can i configure this option?
    Thanks

    We are having the same exact problem. We've done what you've tried with no luck also. Strange thing is that in another building we have the same setup but only with a 6148V blade and that Tandberg has no issues. We're using a 6148AF with the one we're having problems with. We've tried with a 6348 blade and it works fine. I'm thinking it's something with the 6148AF firmware (ver. 8.2(2)).
    Were you able to solve your problem?

  • Connecting Nexus 5548 to Catalyst 6500 VS S720 - 10 G

    good day,
    Could anyone out-there please assit me with basic connectivity/configuration of the 2 devices for the 2 devcies communicate e.g be able to ping each other managemnet interfaces.
    Nexus Configuration:
    vrf context management
      ip route 0.0.0.0/0 10.200.1.4
    vlan 1
    interface mgmt0
      ip address 10.200.1.2/16
    Catalyst 6500:
    interface Vlan1
    description Nexus
    ip address 10.200.1.4 255.255.0.0
    interface TenGigabitEthernet5/4
    switchport
    Note: I am able to get all the devices throught SH CDP NEIG command. assist please.

    Nexus# sh ip int mgmt0
    IP Interface Status for VRF "management"(2)
    mgmt0, Interface status: protocol-up/link-up/admin-up, iod: 2,
    IP address: 10.13.37.201, IP subnet: 10.13.37.128/25
    IP broadcast address: 255.255.255.255
    IP multicast groups locally joined: none
    IP MTU: 1500 bytes (using link MTU)
    IP primary address route-preference: 0, tag: 0
    IP proxy ARP : disabled
    IP Local Proxy ARP : disabled
    IP multicast routing: disabled
    IP icmp redirects: enabled
    IP directed-broadcast: disabled
    IP icmp unreachables (except port): disabled
    IP icmp port-unreachable: enabled
    IP unicast reverse path forwarding: none
    IP load sharing: none
    IP interface statistics last reset: never
    IP interface software stats: (sent/received/forwarded/originated/consumed)
    Unicast packets : 0/83401/0/20/20
    Unicast bytes : 0/8083606/0/1680/1680
    Multicast packets : 0/18518/0/0/0
    Multicast bytes : 0/3120875/0/0/0
    Broadcast packets : 0/285/0/0/0
    Broadcast bytes : 0/98090/0/0/0
    Labeled packets : 0/0/0/0/0
    Labeled bytes : 0/0/0/0/0
    Nexus# sh cdp nei
    Capability Codes: R - Router, T - Trans-Bridge, B - Source-Route-Bridge
    S - Switch, H - Host, I - IGMP, r - Repeater,
    V - VoIP-Phone, D - Remotely-Managed-Device,
    s - Supports-STP-Dispute
    Device-ID Local Intrfce Hldtme Capability Platform Port ID
    3560 mgmt0 178 S I WS-C3560-24PS Fas0/23
    6500 Eth1/32 135 R S I WS-C6509-E Ten5/4
    Nexus# ping 10.13.37.201 vrf management
    PING 10.13.37.201 (10.13.37.201): 56 data bytes
    64 bytes from 10.13.37.201: icmp_seq=0 ttl=255 time=0.278 ms
    64 bytes from 10.13.37.201: icmp_seq=1 ttl=255 time=0.174 ms
    64 bytes from 10.13.37.201: icmp_seq=2 ttl=255 time=0.169 ms
    64 bytes from 10.13.37.201: icmp_seq=3 ttl=255 time=0.165 ms
    64 bytes from 10.13.37.201: icmp_seq=4 ttl=255 time=0.165 ms
    --- 10.13.37.201 ping statistics ---
    5 packets transmitted, 5 packets received, 0.00% packet loss
    round-trip min/avg/max = 0.165/0.19/0.278 ms
    Nexus# ping 10.13.37.202
    PING 10.13.37.202 (10.13.37.202): 56 data bytes
    ping: sendto 10.13.37.202 64 chars, No route to host
    Request 0 timed out
    ping: sendto 10.13.37.202 64 chars, No route to host
    Request 1 timed out
    ping: sendto 10.13.37.202 64 chars, No route to host
    Request 2 timed out
    ping: sendto 10.13.37.202 64 chars, No route to host
    Request 3 timed out
    ping: sendto 10.13.37.202 64 chars, No route to host
    Request 4 timed out
    --- 10.13.37.202 ping statistics ---
    5 packets transmitted, 0 packets received, 100.00% packet loss
    Nexus# ping 10.13.37.203
    PING 10.13.37.203 (10.13.37.203): 56 data bytes
    ping: sendto 10.13.37.203 64 chars, No route to host
    Request 0 timed out
    ping: sendto 10.13.37.203 64 chars, No route to host
    Request 1 timed out
    ping: sendto 10.13.37.203 64 chars, No route to host
    Request 2 timed out
    ping: sendto 10.13.37.203 64 chars, No route to host
    Request 3 timed out
    ping: sendto 10.13.37.203 64 chars, No route to host
    Request 4 timed out
    --- 10.13.37.203 ping statistics ---
    5 packets transmitted, 0 packets received, 100.00% packet loss
    3560#ping 10.13.37.201
    Type escape sequence to abort.
    Sending 5, 100-byte ICMP Echos to 10.13.37.201, timeout is 2 seconds:
    Success rate is 100 percent (5/5), round-trip min/avg/max = 1/1/1 ms
    Note: Now I want to be able to ping Nexus (10.13.37.201) from the 6509 (10.13.37.203), and again be able to ping both the 3560 (10.13.37.202) and 6509 (10.13.37.203) from the Nexus please. How can I do that. I can ping nexus from 3560 as shown above.

  • Span Port Session in Catalyst 6500 & 4500 series

    Hi,
    May I know the maximum monitor session for latest Catalyst 6500 & 4500 series?
    Thanks

    Hi,
    See the below links wich provide all details about the SPAN sessions:
    6500
    http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/ios/12.2SX/configuration/guide/span.html#wp1036881
    4500
    http://www.cisco.com/en/US/docs/switches/lan/catalyst4500/12.2/31sg/configuration/guide/span.html#wp1020415
    Regards,

Maybe you are looking for

  • Field T_STCD1 does not exist in form this erroe msg coming in smartform

    hi, in my smartform, if i give one set of input like, 1st qtr of 2008, vendor and compcode, its displaying the value. but if i give the input like 1st qtr of 2007, vendor and some other compcode its giving some error like field T_STCD1 does not exist

  • Data Source is in Inactive state while replicate datasource in BI 7.0

    Hello, When I replicate the datasource ZW_MAT_PLANT(My own data source which is combination of MARA and MARC) in RSA1-Datasources it is coming by default in inactive mode. In this inactive mode i can not delete this data source assignment adn i can n

  • VGA Splitter

    I just bought a VGA splitter and i hooked it up to my computer it displays both screens. I have a windows 8 HP Pavilion and when i go to devices it says that its a "Generic Non-PNP Monitor". It also doesnt turn up as a projected source. Please help..

  • Service MSS Personnel Developent= Employee Search

    Dear Experts. I have the following issue: In the Manager Self Service =>Team=>Personnel Developent=>Employee Search The portal not update(display) the information of the employee Direct Reports.? I have two user with the same roles. When I assig the

  • RH8 repaint issue. Snippets?

    A bug? in Windows XP? RH 8.01? Snippets? Unable to get RH to open/activate any pods (TOC, glossary, etc) in current project. RH HTML project goes into "not responding" state and does not repaint (part of the pod is visble, but unable to activate it w