Clusters as dynamic events being registered

I am trying to define each of these controls as changevalue events programmatically where I register andd unregister each of the controls that are part of the cluster objects as evenets to the same structure.  I can wire the clusters as references into the register events object fine, but when I try to wire them in direct, I get a conflict error.
Can someone explain to me why this is?
Attachments:
twoclustersasevents.vi ‏49 KB

I am not able to open your vi as it is lacking at least one of the clusters. Try savinging it "Save with Options", "Development distribution", to include all the missing parts.
P.M.
Putnam
Certified LabVIEW Developer
Senior Test Engineer
Currently using LV 6.1-LabVIEW 2012, RT8.5
LabVIEW Champion

Similar Messages

  • Peculiar problem in dynamic event, which is registering randomly

    Hello,
    I am using a dynamic event to pass a data (variant) to a vi which i call dynamically. reference of the event is stored in LV2G.
    so both main and called vi can access. data when written to the generate user event vi is triggering event at random time when executed.
    I am attaching snapshot of the vi which i used to register event.
    One interesting thing i noticed is if i put a probe in the error out of the generate user event vi then event will start triggering.
    Need help. I am struggling to get a solution.
    Regards,
    Vibin
    Attachments:
    Capture.PNG ‏21 KB

    Post any code you have on the issue.  There may be something simple that will fix the problem.  It sounds a lot like a race condition.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • Dynamic event with global variable (vi)

    I have registered a dynamic event to fire when a control in a global vi value changes. All works fine when I open the global vi and change the value of the control manually. When I have another vi modify the value of the global, the dynamic event does not fire.
    I have tried leaving the front panel of the global vi open and observed the value being changed...
    Any help appreciated...

    Hi,
    Please refer to the following document that explains why programmatic changes to the global doesn't get detected.
    Event Structure Does Not Capture the Value Changed Event...
    I hope this helps.
    Sincerely,
    Feroz
    National Instruments

  • Resetting a variable in an event structure (dynamic event)

    I'm working on moving an event structure into a sub VI. This means I have to register dynamic events. 
    The event structure is handling some button clicks. The state of the button (mechanical action = latch when released) resets itself automatically as long as the variable is placed within the value change case.  Leaving the button in this case is not possible when the event structure is put in a sub VI and the variable is located in the parent VI.  How do I make sure the button unlatches after clicking on it?  I have attached an example where all the code is in one VI (the local variable must be moved outside the event structure in order for it to be moved into a sub VI).  Any ideas?
    If you open the VI and run it, you can click Start which will cause the counter to start incrementing.  The button only unlatches as long as the variable is located in the value change case.
    (Btw, how do you put images inline in a post?)
    Rob
    LV2011,LV2012,LV2013
    Attachments:
    img.png ‏18 KB
    main.vi ‏17 KB

    Race conditions are the primary reason not to do that. But since your treating your variable as a latch, I doubt your using the value you read from it anywhere, and in that case it can't create a race condition. There's also the possibility that the control's reference could become invalid. But since this is a sub VI of the control's VI that can't happen (even if it could you can check the error out of the value property node to see when it happens and deal with it).
    I'm not sure about the flickering, Since I can't seem to duplicate it with a simple test case on my machine. It might related to whatever else you're doing in the event apart from reseting the value to false.

  • 2012 Dynamic Event Registration Array of Controls

    In upgrading to LV2012, I have discoverd what may be a bug, or at least an incompatability between 2011 and 2012 with respect dynamic event registration of an array of controls as opposed to individual control references.
    This bit of code worked in 2011 but doesn't in 2012, with error 1 generated at the reg events block when run in 2012. I have been in contact with technical support, but haven't yet heard their take on this.
    Any thoughts.
    Solved!
    Go to Solution.
    Attachments:
    Top Application.png ‏13 KB
    SubVI.png ‏23 KB

    I've got the bug too -- it appears this bug is present when arrays of control refs are connected to the ConPane. Link to cross-post on LAVA about the original problem. As Patrick@Vision mentions above, one workaround is to ensure that the array of control refs is no longer on the ConPane by collapsing the Register for Events node onto the caller.
    a.lia-user-name-link[href="/t5/user/viewprofilepage/user-id/88938"] {color: black;} a.lia-user-name-link[href="/t5/user/viewprofilepage/user-id/88938"]:after {content: '';} .jrd-sig {height: 80px; overflow: visible;} .jrd-sig-deploy {float:left; opacity:0.2;} .jrd-sig-img {float:right; opacity:0.2;} .jrd-sig-img:hover {opacity:0.8;} .jrd-sig-deploy:hover {opacity:0.8;}

  • Are you ever required to wire the dynamic event terminals through an event case?

    I remember some time ago, I ran into an issue while using an event case where my program was not functioning properly until, on a whim, I wired the dynamic event through that event case... now the reason I'm asking this in a general sense is because I don't remember what particular code I had this issue with and I could have been failing to update a shift register or something.
    In code I'm currently writing, I'm simply passing the dynamic event wire in a shift reg.  I was just wondering if there's any difference between wiring it through the event cases or simply passing it to the output shift register (without passing through the event cases)...
    any info appreciated!
    Thx
    -pat

    You do not have to wire it through. You don't need a shift register for references since the value will be the same for each iteration. In fact using a shift register is probably what caused issues. You probably updated it with the default value somewhere.
    =====================
    LabVIEW 2012

  • Tag engine dynamic events

    Does anyone have an example using dynamic events with tag values from the DSC engine?? I use 7.0 format.

    hi there
    you can combine DataSocket Read - function with timeout and a registered user event (see attachment)
    Best regards
    chris
    CL(A)Dly bending G-Force with LabVIEW
    famous last words: "oh my god, it is full of stars!"
    Attachments:
    Wait for Tag to change ist value_7.1.vi ‏74 KB

  • Dynamic Event Registration Error

    Hi,
    I'm getting to grips with Dynamic events in LabVIEW. However, I've encountered an issue i'm not sure on. When I try to register a cluster of control refs to the Register for Events function I get an error.. See Dynamic Event Registration.vi for small vi highlighting the issue.
    Thoughts?
    Strokes 
    Attachments:
    Dyanmic Event Registration Error.vi ‏9 KB

    Steve Chandler wrote:
    You can wire a reference or an array of references to register for events. Of course you probably already know that you have to wire the output of register for events to the dynamic registration terminal of the event structure.
    Steve Chandler wrote:
    You can wire a reference or an array of references to register for events. Of course you probably already know that you have to wire the output of register for events to the dynamic registration terminal of the event structure.
    That helped me somewhat, however, I'm still experiencing problems. My events seem to be registering correctly but don't seem to generate when I trigger them. I've configured the event structure to execute should one of the controls in my cluster change value. However, the only event case that get's executed is the timeout case.
    I've attached a vi highlighting my problem named Dynamic Event Problem.vi. My real vi is much larger and contains many sub vis so hopefully what I've attached suffices..
    Attachments:
    Process Data Control Refs Edit.ctl ‏14 KB
    Dynamic Event Problem.vi ‏22 KB

  • Dynamic Events Problem

    I am fairly new to LabVIEW and I am trying to make a GUI that uses
    events to pass messages between three separate event loops, GUI,
    Messaging and Logging. GUI controls the state of the other two event
    loops by generating control events and using semaphores. While the
    messaging semaphore is released by the GUI, Messaging generates
    messages and raises them as events. Some message events are handled by
    the GUI event loop and others by the Logging event loop. Logging, once
    it receives a 'logging ON' control event dynamically registers for
    certain message events and logs the message events it handles to file.
    When Logging receives a 'logging OFF' control event, it dynamically
    unregisters the message events. The logging control events are
    registered for the life of the Logging event loop.
    I have created a cut-down version of my GUI that exhibits the same
    problem. The problem is that after I have turned Logging on and off
    once, it no longer responds to logging control events from the GUI.
    Even though the GUI is still generating the events. I have looked at
    the dynamic logging example in LabVIEW and thought I did the same sort
    of thing but I just can't get it to work that way. The only way I got
    it working was by creating a clean event registration with all events
    each time I want to change the event registration. This is how I have
    done it in the example file and it works. But I don't want to use this
    method, I don't want to have to re-register the control events each
    time I unregister/register message events.
    If anyone knows what I'm doing wrong please edit the example vis and post them back.
    Notes for the example:
    Files are LabVIEW 7.1.1
    Just open the front panels for all the vis before running the GUI vi.
    The Display vi just does the same thing as the logging vi.
    Run the GUI vi and turn on Messaging then turn Logging on and off a few times.
    The example works, but if you wire the event registration refnum
    input when doing dynamic event registration, Logging will only turn on
    and off once, then no longer respond to log control events... what's
    going on?

    I can't tell you how to solve you problems - without code this is always quite tricky.
    But in case you want to log messages to a log file, have a look at this thread
    http://forums.ni.com/ni/board/message?board.id=170&message.id=172117&view=by_date_ascending&page=1
     where I posted a logging-library.
    Maybe it is a useful help for you.
    Thomas
    Using LV8.0
    Don't be afraid to rate a good answer...

  • Generate dynamic event of producer loop in multiple consumer loop

    I have one producer loop which used event case to interface with FP controls and 5 consumer loops
    If I have to use the fifth consumer loop to generate dynamic event which send to event case in produer loop. 
    I have to wire register event with dynamic event terminal in producer loop . Also I need to wire user event to consumer loop (at the bottom of screen window) which is far away from producer loop. It is hard to wire them. 
    Is there any other method to let many consumer loop to communicate with one producer loop through dynamic event (the same user event)?

    I like to use an Action Engine to hold control my Event Reference.  Then anybody can send the event commands.
    You may also want to look at the VIs I recently submitted for OpenG here.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • Extending EventDispatcher with dynamic event types

    I'm currently trying to write my own class to extend the
    EventDispatcher class. My goal is to create a Service class which
    acts as a switchboard for incoming socket data. Incoming socket
    data is parsed to create an Event which is Dispatched to the
    appropriate Service object which dispatches the event to any
    registered listeners.
    The problem I'm having is that I'm confused about how to
    handle the event types -- the string parameter which is always
    supplied as the first argument to the addEventListener() function.
    In all the examples I've seen, the value supplied is a class
    constant like MouseEvent.CLICK or VideoEvent.READY. In the case of
    my application, I want the developer to define their own Event
    types without having to go and edit my class files. In other words,
    I'd like to use dynamic event types with my class--maybe something
    like the code I've attached.
    I'm not new to Actionscript but am very new to the
    EventDispatcher class. I'm wondering a bit what that first
    parameter really does in a strict programming sense -- i haven't
    seen it explained all that well in the piles of documentation I've
    read on the Adobe site so I don't really know if I need to define
    my own Event class or what and whether I have to define all those
    possible event type constants/strings in advance or what.
    Any help/advice would be much appreciated.

    I have looked it up here:
    Actionscript
    3.0 Language Reference
    and it just says that the first arg to 'addEventListener' is
    "The type of event" with no further explanation at all.
    I have read this:
    Flash
    Quick Starts: Programming With Actionscript 3.0: Event handling
    It doesn't help much either. It tells me I need the
    appropriate event object which makes me wonder DO I NEED MY OWN
    CLASS? For that first ard to addEventListener, it merely says
    "Substitute the appropriate constant". Given that I want to use
    dynamic types (i think so anyway) that is not helpful information
    either. Every single example on that page uses a class constant for
    event type.
    It links to
    this
    which says "First, the name of the specific event you want to
    respond to. Once again, each event is affiliated with a specific
    class, and that class will have a special value predefined for each
    event--sort of like the event's own unique name, which you should
    use for the first parameter." Still no useful detail about what
    that arg does and the insistence on constants.
    The quick start page also has a link title "Handling Events"
    in Programming ActionScript 3.0 but it links to some documentation
    titled "Working with XML". The only discussion of events in that 10
    or so pages is because some user posted a comment.
    I have read this
    entire
    article which is more helpful than anything in the flash docs
    but still doesn't answer all my questions which (AGAIN) are:
    1) What is the real function of the first argument to
    addEventListener? I have not seen a clear explanation anywhere.
    2) Do I need to write my own Event class?
    3) What about dynamic event types that are defined at
    runtime? Are there any pitfalls or risks that arise from using a
    string instead of a predefined constant as the first param to
    addEventListener() ?
    Please stop telling me to read the documentation. I've been
    reading it for days.

  • Dynamic Event (Notifier) Missed

    In my application, I have a notifier registered as a "user event". There are three event structures, each within a while loop; in each event structure this notifier event is registered as "dynamic event". In two structures, the timeout is set to "-1" (infinite). In the third stcructure, the timeout is set to 5 ms; the timeout case takes 500 ms to complete (e.g. using "Wait ms"). An additional event structure fires this notifier event.
    What happens is that the two structures with infinite timeout catch this event (I think), but the structure with a short timeout and long-executing timeout case misses it. If I make the timeout long and the timeout case execute fast, this structure also catches the event. It looks like during the execution of the timeout case the event is unregistered.
    An example VI is attached.
    Is it a bug or am I doing something wrong?
    Thanks,
    Sergey Liberman
    Message Edited by Cepera on 02-12-2010 10:29 PM
    Solved!
    Go to Solution.
    Attachments:
    NotifierTest.vi ‏17 KB

    You are right of course. I forgot that events do not broadcast. A corrected VI is attached. It works fine now. Thanks!
    Attachments:
    NotifierTest2.vi ‏19 KB

  • Dynamic event registrati​on wont work with Tab control

    In LTR volume 11 No1 we find the "Dynamic Event Handling.vi".
    I had placed the controls on a Tab control and now this example wont work.
    Is there a solution to this problem?
    Scientia est potentia!
    Attachments:
    Dynamic_Event_Registration.vi ‏51 KB
    Dynamic_Event_Registration(controls_on_Tab).vi ‏64 KB

    Yes. The first stage of the code registers mouse down events for all the controls. When you added a tab control that meant that a mouse down event was registered for the tab as well. So now when you click on an object on the tab LabVIEW must decide whether to fire the mouse down on the tab-event, or the mouse down on the object on the tab event...It goes for the first but since there is no description for the tab no dialog will be displayed. If you add a description for the tab you'll see that it fires the event with the tab and you get a dialog with the tab description.
    So - how to fix. Well, it's not that simple, one might think that to exclude the reference to the tab when you register the events would do the trick, but it rather seems that LV will always t
    hink mouse clicks are on the tab and not on the objects on the tab.
    The solution though is to get the references to the objects by reading the controls on page property of the tab control. So instead of reading the controls array from the front panel read the pages references of the tab and then the controls on page array from that and then register mouse down events on that array.
    MTO

  • Dynamic event registrati​on - FP not in memory ?

    Hello,
    I have problem that I don't understand tith dynamic event registration.
    In my app I have many threads that are initialised when app starts and I switch between them using subpanel.
    In one of this modules I want to register some dynamic events to find whitch controll in cluster was pressed.
    Why I get error 1001?
    I have static reference for all modules in main thread. I start modules but I don't open their FP.
    Solved!
    Go to Solution.
    Attachments:
    err.png ‏30 KB

    Well your image is confusing because you can't run without wiring that reference.  But if you did do that then the error comes from the fact that your VI doesn't have a front panel that is open when you register for it.  So that control reference doesn't really exists.  I mean it exists but you can't reference a control that hasn't been opened.
    I think what you'll want to do is open the front panel, but then set it to hidden.  Then after the front panel has been opened, and hidden, register for the control event.
    Unofficial Forum Rules and Guidelines - Hooovahh - LabVIEW Overlord
    If 10 out of 10 experts in any field say something is bad, you should probably take their opinion seriously.

  • Dynamic event multiple loops

    I'm trying to see if I can use one Dynamic User Event to control multiple Event Structures. It seems that sometimes once a dynamic event occurs and its "interrupt" is answered by an event case, other VIs only have a short amount of time (<50ms) to reach their event case state for accepting this event otherwise the event seems to be cleared and the other VIs are oblivious that the event even occured.
    My Question: Is it possible to use one dynamic event to control multiple Event Structures reliably?
    A previous post somewhat speaks of this issue but does not provide a solution or anything insightful.
    http://forums.ni.com/ni/board/message?board.id=170&message.id=223495&query.id=135563#M223495
    I've included an example of my issue
    Attachments:
    DynamicUE.zip ‏61 KB

    Thanks to both of you. I found the answer to my question in the second posted link. "the common, correct use case is to have one Event structure per dynamic event registration". I tested this out with the previous attachment by registering the User Event refnum from the ESTOP functional global to another Event Registration node. I then ran this refnum to the top loop. (instread of the top loop sharing the registration refnum with the middle loop). Now I can put a delay of 2000+ ms and not even miss an event. cooool. This will probably NOT be my final solution but its good to know in the future.
    Most likely I am going to design each of my main VIs to have a main while loop with a User Event Structure listening for dynamic events. Associated with each of these VIs will be a functional global which contains its User Event Refnum and Registration Refnum. This functional global will act as a gateway into the associated VI for other VIs/Subvis to use. This will follow the "one Event structure per dynamic event registration" rule while keeping my API organized and allowing room for scalability by simply adding more functional globals in the future.
    Just putting this info out there for other users.
    Thanks again,
    Craig

Maybe you are looking for

  • Insert delete or update entry in Custom table from KONV entry changed

    Hi All, I have custom table ZKONV with only few required columns and should have same number of records as KONV has at any point in time. KONV is a cluster table so its not readable from ORACLE level. So ZKONV is created. But I dont know how to keep

  • Missing a QT handler

    Hi, when trying to export or publish a movie using QT format- keep getting an error dialog stating that the installed version of QT does not have a handler for this type of Macromedia flash movie. Am using QT Pro 7.1.5, on a Mac system. Have Flash MX

  • Can't set staff style preferences

    I'm trying to score a choral arrangement, so I need two treble channels, two bass and one for the piano. The style settings in the inspector windows both in the arrange window and the score window will not reset. The style in the arrange window says

  • Tabbed Panel Widget

    I have two questions about changing the behavior of the SPRY tabbed-panel widget that come with CS3 DW. For those very familiar with this widget the answers should be easy. 1) Is it possible to close all tabs and have each panel of a tab open only wh

  • WCF-WebHttp REST configuration

    I'm trying to configure the WCF-WebHttp adapter to retreive data from a REST endpoint, specifically a contact in CRM.  I need to include a filter to return only the contact that I want.  When I include a hardcoded value in the Uri it works fine: <Bts