COM/DCOM Error for RFC CRMXIF_ORDER_SAVE
Hi everybody,
I'm trying to create a SalesOrder from within a VBA environment on a SAP CRM 3.1 system. There is a SalesOrderCRM object on the system but only the God and probably the SAP knows how the input_field structure of the CreateDetailMulti BAPI/Method is to be filled for the method to work properly. I've been using the CRMXIF_ORDER_SAVE to create new Sales Ordersfrom my ABAP programms it was simple, fast and worked perfectly. Now I wanted to do the same thing from a VBA enviroment but when i try to wrap the function I get this error on the SAP DCOM Connector 'Cannot map RfcType 0x1c'. Access through the "SAP.Functions" Active X control fails too. With other BAPI's I'm not having problems of any kind, they can be mapped and accesed from VBA without problems. It seems to me that the data structure of the parameter DATA is just to complex to be mapped. Does anybody has any other idea's, how is this problem to be confronted?
Cheers
Astrit
P.S.
I'v already updated my workstation to the latest version of the librfc32.dll
Hello Astrit,
We are also creating sales contract document (object BUS2000121) by calling crmxif_order_save in a ABAP Program but the performance is very bad for example if i have to create a sales contract document containing 1000~1200 items, the function module is taking more than 3 hours.
Have you ever faced such a performance problem?
Have you aware of any flag setting in the input data
structure of crmxif_order_save which will improve the performance?
If you have any tips then pls let me know.
Best Regards
Ravi
Similar Messages
-
Is there COM/DCOM adapter for XI available?
Hi colleagues!
I need to integrate SAP XI with 3d party program and communication between them must be organized with COM/DCOM objects.
Is there COM/DCOM adapter for XI available? Or if not, then how to substitute it?
Thanks!Hi Alexander,
Can you pls share how did you finally acheive this integration.Any help would be much appreciated.
Many Thanks,
Ashok -
Message mapping transformation error for RFC calls
Hi,
I am having a weird problem. recently client migrated the server and we started getting all possible errors in XI which we are able to fix. Now we have a strange problem in quality system alone where the bapi calls are made from QA11 and MIGO. The bapi call from MIGO is sucessfull but from QA11 it fails with below error
com.sap.aii.utilxi.misc.api.BaseRuntimeException
thrown during application mapping
com/sap/xi/tf/_MP_RFC_PROXY_GOODS_RECEIPT_:
RuntimeException in Message-Mapping transformatio~
I checked in development system and production where it is sucessfull but in quality its failing. I checked the cache and refreshed for confirmation and checked the trace and log files but couldt find any solution. The call made from a test report is also sucesfull but only bapi calls from QA11 are failing.
Note: i am using same bapi in MIGO and QA11 and the integration is same as well. There is no difference in data between 2 transaction just the trigerring point is differenct.
I tested my message mapping, interface mapping and configuration as well with sample payload and they are working fine.
I checked SDN and saw that similar issue is faced by others but no solution is provided.
Regards,
Jayaram
Edited by: JAYARAM MAGANTI on Jun 9, 2009 1:14 PMHi all,
Has anyone ever faced this issue?
i tried all the options that i think of and as a last attempt even restarted XI engine though it makes no sense. but still i am having the same issue.
If anyone had come across similar kindly update the solution
Jayaram -
Error in RFC Adapter PI 7.10 maximum size of requests for one LUW
Hello all,
I have a big issue on our Development - SAP PI 7.10 System. If I try to push a RFC from a Client System
I get follow error messagei in the Runtime Workbench (RWB) back:
processing error to be caused by: com.sap.aii.adapter.rfc.core.server.RfcServerException: maximum size of requests for one LUW has been reached (1). handling of request for tRFC (TID: 0AA001B8712C49D35D4D06C2) not possible (server: RfcServer[PKG_R3_D07_600_RFC_SND]1)
But I don't know why. I checked follow OSS Notes:
730870 and 774705 w/o success. It will be nice somebody can help me.
Thanks
S. Kohler
P.S. We have the same scenario in our Quality SAP XI System and there works. I couldn't find any
differences between the Adapters. Is there a problem with the parameters ????Hello Tarang Shah,
okay. Here again ( I thought I mentioned above):
in Q50 (SAP PI 7.10 System) we create a RFC Server with the program ID RFC_Q50.
in D64 (SAP PI 7.10 System) we vreate a RFC Server with the program ID RFC_D64
in D07 (SAP R/3 4.7 x110) we create a RFC Connection to D64 with the program ID RFC_D64.
The testconnection works well. I see in our Dev. SAP PI System (D64) that the connection works.
The problem is here, if you start in the application (System D07) the push, you get the error :
maximum size of requests for one LUW has been reac hed (1). handling of re
in Q50 (SAP R/3 4.7 x110) we create a RFC Connection to Q50 with the program ID RFC_Q50.
The testconnection in Q17 works well. Also the push from the application (System Q17.)
This means, the functionallity is okay on both sides (Q17 and D07) only the application sending
process from D07 makes trouble ( you see in Transaction SM 58 on Client Site, the error as I mentiond above and in SAP PI side.) It seems that SAP PI could't accept more as one LUWs
in the same time. Q50 (Q- System) accepted.
So, this is the reason in my point of view, that the problem isn't the connection, seems more
an paramter problem in D64 side. But I don't know which parameters. I checked the OSS Note 730870 and 774705 w/o success.
Thanks
S. Kohler -
Hello All,
Does anyone know what this message means? All our programs using RFC to send data to another system is encountering error below. Please help.
Error in processing caused by: com.sap.aii.af.rfc.afcommunication.RfcAFWException: alternativeServiceIdentifier: party/service from channel configuration are not equal to party/service from lookup of alternativeServiceIdentifier (CPA party/service/channel ''/'ZBS_R3BACKEND2'/'CC_MQ_Rfc_Outbound', lookup of alternativeServiceIdentifier for party '', schema 'TechnicalSystem' with 'QAS#100' returned party/service of ''/'ZBS_R3BACKEND')
Regards,
AlfredHi
have u configured the Bussiness System with correct client which u r trying to connect?
check if u have imported RFC from right client.
rgds
srini -
Error when executing multiple scenarios with same ProgramID for RFC-JDBC
Hi,
I am working on the RFC-JDBC scenario.
I see the following error in the dev_jrfc.trc file when I try to execute multiple scenarios which are using same program id (different communication channels).
RfcException:
message: Commit fault: com.sap.aii.af.rfc.afcommunication.RfcChannelMismatchException: Wrong Sender Agreement:The Sender agreement does not have channel CC_SAP_XXXXX configured for the functionmodule Z_XXXXX_SO_CREATE_CHANGE
Return code: RFC_CLOSED(6)
error group: 108
key: RFC_ERROR_INTERNAL
Can one program id be used for multiple scenarios? Or do we need to create a new ProgramId for each scenario.
Any response will be highly appreciated.
Thanks
ShyamHello Shyam,
>>>>>>>>Do you think that I still need to create a new Program Id for each of these processes.
You should not use same program ID for different RFC adapters. It is recommended by SAP (check FAQ's on RFC).
Although technically you can use but it gives you unpredictable behaviour based on connection pool. -
Hey guys,
I've used xp_cmdpowershell from SQL Server 2008 R2 to execute a powershell scripts.
One of this scripts creates a internetexplorer.application object.
When I execute this script on powershell(version 2.0), it runs.
But when trie to execute for xp_cmdpowershell it fails.
error output:
Retrieving the COM class factory for component with CLSID {0002DF01-0000-0000-C000-000000000046} error: 80070005
script example:
$ie = New-object -com 'internetexplorer.application'
$ie.navigate("http://www.google.com")
$ie.visible = 1
sleep -s 10
$ie.quit()
xp_cmdpowershell example:
EXEC master..xp_cmdshell 'powershell C:\DataLocalTopRonda\scr.ps1';
Anyone have any ideas? Any help will be appreciated.8007005 is typically 'Access Denied'. Did you verify DCOM permissions to this class object? Are you using the same credentials in the PowerShell console as what is being done in SQL?
Boe Prox
Blog |
Twitter
PoshWSUS |
PoshPAIG | PoshChat |
PoshEventUI
PowerShell Deep Dives Book -
Hi,
I have excel 2013 Professional installed and i have created a windows service to open the excel document and read it.
Service is running as System account.
Now when i am trying to access the excel doucment, it is throwin the exception as
EXCEL COM ERROR Error Retrieving the COM class factory for component with CLSID {00024500-0000-0000-C000-000000000046}
however, when i am using the console application running as administrator, i am able to open same file.
Any yes, i am using 64 bit service C++ and excel binaries are Any CPU.
Please note: I have already tried using dcomconfig and assigned full permission to the system user.
Is there any other solution for this issue.
regards
PushpendraHello Pushpendra,
Microsoft does not currently recommend, and does not support, Automation of Microsoft Office applications from any unattended, non-interactive client application or component (including ASP, ASP.NET, DCOM, and NT Services), because Office may exhibit
unstable behavior and/or deadlock when Office is run in this environment.
If you are building a solution that runs in a server-side context, you should try to use components that have been made safe for unattended execution. Or, you should try to find alternatives that allow at least part of the code to run client-side.
If you use an Office application from a server-side solution, the application will lack many of the necessary capabilities to run successfully. Additionally, you will be taking risks with the stability of your overall solution.
You can read more about that in the
Considerations for server-side Automation of Office article.
Consider using the Open XML SDK, see
Welcome to the Open XML SDK 2.5 for Office . Also any third-party components can be used instead. -
RFC system error for destination GTADIR_SERVER
I just installed trial version 7.0 ABAP SP12. I started the learning path displayed in SE80, create a table and some class for working with it.
When trying to create a data-element I get the error "RFC system error for destination GTADIR_SERVER". Any hints about what this server is and how to set it up?This message is not supposed to appear for customers, but it doesn't cause any harm either. You can click through and ignore it.
The message is removed for customers in SP13. Check OSS Note 1063482. -
"RFC system error for destination GTADIR_SERVER",why?
RFC system error for destination GTADIR_SERVER
Hi AlL,
We are working in CRM 6.0.
While creating the Components and Views,i am encounter this Error.
<<
"RFC system error for destination GTADIR_SERVER"
Message no. SGSUB104
Diagnosis
Access to destination GTADIR_SERVER is currently not possible.
System Response
There was a problem with the execution of the function through a Remote Function Call (error in commmunication or communication setup).
The entered destination was GTADIR_SERVER.
The RFC error message reads:
RFC destination GTADIR_SERVER does not exist.
Die Aktion wurde deshalb abgebrochen.
Procedure
Wiederholen Sie die Aktion sp鋞er.
Wenn die Destination GTADIR_SERVER 黚er einen l鋘geren Zeitraum hinweg nicht erreichbar ist, dann verst鋘digen Sie die Systemadministration f黵 GTADIR_SERVER.
Procedure for System Administration
Weitere Informationen - siehe Systemprotokoll in Destination GTADIR_SERVER.
>>
Any ideas?
Thanks & Regards
Edited by: Autumn of Desert on Oct 12, 2009 8:33 AMCancelled
-
Can anyone help my itunes stops working when i connect my ipad to my computer a windows error message comes up looking for solution but then closes itunes.
Hi tokley13,
To troubleshoot this issue where iTunes is quitting unexpectedly, please follow the steps in the article below.
iTunes for Windows Vista, Windows 7, or Windows 8: Fix unexpected quits or launch issues - Apple Support
Thanks for using the Apple Support Communities!
Cheers,
Alex H. -
I am trying to restore my apple and update it. It comes up error 3014 and -1. Any ideas for help?
Try the following user tip:
Troubleshooting issues with iTunes for Windows updates -
Runtime Error: "Time out" for RFC.
Hi,
During RFC, I am getting a runtime error stating "Timeout error". Even while the job is run in background I am getting this error. Seems like the time for RFC task is set to 600 secs.
How to resolve this and is there any way we can see time limit set for different tasks?
thanks,
ArunHi,
More info: I am using multithreading or mass processing technique, so the logic has to be written in FM which has RFC enabled. So while the task is in process in background it exceeds the time limit set for RFC i.e 600secs.
Sample code:
CALL FUNCTION 'ZZ_ABC'
STARTING NEW TASK gv_task
DESTINATION IN GROUP gv_grp
PERFORMING rcvb_endprocess ON END OF TASK
EXPORTING
e_batch_date = gv_batch_date
FORM rcvb_endprocess "#EC CALLED
USING gv_task TYPE any. "#EC NEEDED
RECEIVE RESULTS FROM FUNCTION 'ZZ_ABC'
TABLES
t_receivables = it_receivables.
gv_rcvd = gv_rcvd + 1.
ENDFORM. " RCVB_ENDPROCESS -
BPM Exception handling for RFC errors
Hi all
I have to handle the exception which would be like below:
com.sap.aii.af.ra.ms.api.DeliveryException: error while processing message to remote system:com.sap.aii.af.rfc.core.client.RfcClientException: could not get a client from JCO.Pool: com.sap.mw.jco.JCO$Exception: (102) RFC_ERROR_COMMUNICATION: Connect to SAP gateway failed
I am trying to put Block step and things are not working fine. Can anyone please explain me the steps to trap the exception?
My scenario has synchronous call to RFC FM.
Rightnow i have inserted Exception branch in my Block step and put the send step to write the error file. I have put the Synchronous SEND step as part of block. This is not working.
Help please??Hello Samuel,
Just to close this thread and finish up my own search, where I met your discussion, here I'm quoting two experts of this forum:
"you cannot catch the exception's value in the XI "
(see posting from Michal Krawczyk, Jun 12, 2006, in thread catch the exception)
"The content of a fault message are not accessible inside a BPM."
(see posting from Bhavesh Kantilal, Oct 3, 2007, in thread Notify user about Exception in BPM)
Regards,
Dennis -
Error on live web server - Retrieving the COM class factory for component
I've had a good read of this forum and can't find the answer to this particular issue. Everything works fine until I upload my vb.net/crystal reports solution to my live production web server. The error I get when I try to open a Crystal Report from the web is:
Retrieving the COM class factory for component with CLSID {059AC10F-0010-4C43-8876-1FC7BEAF218B} failed due to the following error: 80070005.
It is the following line of my VB.net source code that causes the error.
Dim oRpt As New CrystalDecisions.CrystalReports.Engine.ReportDocument
I've installed CRRuntime_12_0_mlb.msi to my Windows 2008 / IIS7 web server (This is a 64bit server).
The website works fine on a 32 bit system but on this new server I keep getting the above errors.
I've tried resinstalling the crystal reports numerous times and restarting. I've also tried installing the SP2 version of the CRRuntime and still get the same errors.
I've added read/write permissions to Windows/Temp directory for Network Service.
I've tried to manually register sacommlayer.dll which registers correctly.
The website is not compiled into a binary, the aspx.vb files are simply uploaded to the webserver and compiled on the fly by the server.
I've tried to add <identity impersonate="true" userName="MACHINENAME\administrator" password="PASSWORD" /> into the web.config file to see if this gets any further.
It does however then errors on the following VB Line.
oRpt.SetDataSource(dsSWMP)
with the error
Failed to load database information.Error in File crSitewasteManagementPlan {BEC6811A-D612-4ED6-9AF7-B0C9BED7A966}.rpt:
Failed to load database information
I've also tried opening up the C: / D: drives to the NETWORK SERVICE account with full control (temporarily) to see if I can get past the errors, however this has not worked for me.
Any other ideas to why this might not be working? Ideally I would not like to be using the identity impersonation at all.
Kind Regards
JamesDear Ludek,
I have tried manually registering the sacommlayer.dll already however this didn't make a difference.
I have checked versions of this DLL between the 2 servers and they are the same. (v12.0.0.683)
Find below the logs from process monitor for the 64 bit server.
It definitely shows where it is failing.. any suggestions to fix it?
I can email more detailed logs if you supply me with your email address.
Kind Regards
James
processes from erroring 64 bit server
00:28:46.6463180 w3wp.exe 3948 RegOpenKey HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B} SUCCESS Desired Access: Read
00:28:46.6463685 w3wp.exe 3948 RegOpenKey HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B}\TreatAs NAME NOT FOUND Desired Access: Query Value
00:28:46.6463935 w3wp.exe 3948 RegQueryKey HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B} BUFFER TOO SMALL Query: Name, Length: 0
00:28:46.6464137 w3wp.exe 3948 RegQueryKey HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B} SUCCESS Query: Name
00:28:46.6464472 w3wp.exe 3948 RegOpenKey HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B}\Progid NAME NOT FOUND Desired Access: Query Value
00:28:46.6464701 w3wp.exe 3948 RegQueryValue HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B}\(Default) SUCCESS Type: REG_SZ, Length: 54, Data: InProcAdapterMonitor Class
00:28:46.6464924 w3wp.exe 3948 RegQueryValue HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B}\(Default) SUCCESS Type: REG_SZ, Length: 54, Data: InProcAdapterMonitor Class
00:28:46.6465262 w3wp.exe 3948 RegOpenKey HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B}\InprocServer32 SUCCESS Desired Access: Read
00:28:46.6465561 w3wp.exe 3948 RegQueryValue HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B}\InprocServer32\InprocServer32 NAME NOT FOUND Length: 144
00:28:46.6465759 w3wp.exe 3948 RegQueryValue HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B}\InprocServer32\(Default) BUFFER OVERFLOW Length: 144
00:28:46.6465958 w3wp.exe 3948 RegQueryValue HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B}\InprocServer32\(Default) BUFFER OVERFLOW Length: 144
00:28:46.6466137 w3wp.exe 3948 RegQueryValue HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B}\InprocServer32\(Default) SUCCESS Type: REG_SZ, Length: 196, Data: C:\Program Files (x86)\Business Objects\BusinessObjects Enterprise 12.0\win32_x86\sacommlayer.dll
00:28:46.6466339 w3wp.exe 3948 RegQueryValue HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B}\InprocServer32\ThreadingModel SUCCESS Type: REG_SZ, Length: 10, Data: Both
00:28:46.6466578 w3wp.exe 3948 RegCloseKey HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B}\InprocServer32 SUCCESS
00:28:46.6466904 w3wp.exe 3948 RegOpenKey HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B}\InprocHandler32 NAME NOT FOUND Desired Access: Query Value
00:28:46.6467217 w3wp.exe 3948 RegOpenKey HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B}\InprocHandler NAME NOT FOUND Desired Access: Query Value
00:28:46.6467441 w3wp.exe 3948 RegCloseKey HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B} SUCCESS
00:28:46.6468194 w3wp.exe 3948 RegOpenKey HKU\S-1-5-21-3073440563-3662229771-834689312-1170_Classes\Wow6432Node NAME NOT FOUND Desired Access: Maximum Allowed
00:28:46.6468529 w3wp.exe 3948 RegOpenKey HKCR\Wow6432Node SUCCESS Desired Access: Maximum Allowed, Granted Access: Read
00:28:46.6468904 w3wp.exe 3948 RegOpenKey HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B} SUCCESS Desired Access: Read
00:28:46.6469158 w3wp.exe 3948 RegCloseKey HKCR\Wow6432Node SUCCESS
00:28:46.6469458 w3wp.exe 3948 RegOpenKey HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B}\TreatAs NAME NOT FOUND Desired Access: Read
00:28:46.6469678 w3wp.exe 3948 RegCloseKey HKCR\Wow6432Node\CLSID\{059AC10F-0010-4C43-8876-1FC7BEAF218B} SUCCESS
00:28:46.6471878 w3wp.exe 3948 QueryOpen C:\Program Files (x86)\Business Objects\BusinessObjects Enterprise 12.0\win32_x86\sacommlayer.dll FAST IO DISALLOWED
00:28:46.6473271 w3wp.exe 3948 CreateFile C:\Program Files (x86)\Business Objects\BusinessObjects Enterprise 12.0\win32_x86\sacommlayer.dll ACCESS DENIED Desired Access: Read Attributes, Disposition: Open, Options: Open Reparse Point, Attributes: n/a, ShareMode: Read, Write, Delete, AllocationSize: n/a
00:28:46.6476098 w3wp.exe 3948 CreateFile C:\Program Files (x86)\Business Objects\BusinessObjects Enterprise 12.0\win32_x86\sacommlayer.dll ACCESS DENIED Desired Access: Read Data/List Directory, Synchronize, Disposition: Open, Options: Synchronous IO Non-Alert, Non-Directory File, Attributes: n/a, ShareMode: Read, Delete, AllocationSize: n/a
00:28:46.6478526 w3wp.exe 3948 QueryOpen C:\Program Files (x86)\Business Objects\BusinessObjects Enterprise 12.0\win32_x86\sacommlayer.dll FAST IO DISALLOWED
00:28:46.6479856 w3wp.exe 3948 CreateFile C:\Program Files (x86)\Business Objects\BusinessObjects Enterprise 12.0\win32_x86\sacommlayer.dll ACCESS DENIED Desired Access: Read Attributes, Disposition: Open, Options: Open Reparse Point, Attributes: n/a, ShareMode: Read, Write, Delete, AllocationSize: n/a
00:28:46.6482284 w3wp.exe 3948 CreateFile C:\Program Files (x86)\Business Objects\BusinessObjects Enterprise 12.0\win32_x86\sacommlayer.dll ACCESS DENIED Desired Access: Read Data/List Directory, Execute/Traverse, Synchronize, Disposition: Open, Options: Synchronous IO Non-Alert, Non-Directory File, Attributes: n/a, ShareMode: Read, Delete, AllocationSize: n/a
00:28:46.6484770 w3wp.exe 3948 CreateFile C:\Program Files (x86)\Business Objects\BusinessObjects Enterprise 12.0\win32_x86\sacommlayer.dll ACCESS DENIED Desired Access: Execute/Traverse, Synchronize, Disposition: Open, Options: Synchronous IO Non-Alert, Non-Directory File, Attributes: n/a, ShareMode: Read, Delete, AllocationSize: n/a
00:28:46.6489837 w3wp.exe 3948 QueryOpen C:\Windows\SysWOW64\inetsrv\w3wp.exe.config FAST IO DISALLOWED
00:28:46.6490819 w3wp.exe 3948 CreateFile C:\Windows\SysWOW64\inetsrv\w3wp.exe.config NAME NOT FOUND Desired Access: Read Attributes, Disposition: Open, Options: Open Reparse Point, Attributes: n/a, ShareMode: Read, Write, Delete, AllocationSize: n/a
sacommlayer.dll 12.0.0.683
Edited by: sw1sher2 on Feb 18, 2010 1:55 AM
Maybe you are looking for
-
F.01 - extract to consolidation on company code level
Hi everyone We're trying to do an extract to consolidation on company code level (1). When popup dialog "Filename for extraction file" appears we can choose between presentation server or application server. When choosing presentation server and logi
-
Why the snap_id is not generated sequentially in statspack?
I submitted some snaps manually, and thru dbms_job, the snap_ids are not sequential: SQL> select SNAP_ID,to_char(SNAP_TIME,'DD-MON-YY HH24:MI') timestamp from stats$snapshot order by 1; SNAP_ID TIMESTAMP 1 22-AUG-06 08:19 2 22-AUG-06 08:19 3 22-AUG-0
-
FI: Payment condition calculating 2 due-dates depending on document-date
Hello community! I'm searching for a definiton of a FI-payment-condition which is calculating two different due-dates depending on document-date. E.g.: Invoices dated from 01.03.08 till 09.03.08 should be paid on 10.04.08. Invoices dated from 10.03.0
-
Help with accounts and finding Safari.
I set up new accounts on my Mac for my kids. Now my kids accounts can't access Safari at all. While in their accounts I can't find it in the applications folder either. I am not good at managing my Mac.
-
Moving CS6 and Lightroom 4 to new computer
Is there a way to install upgrade versions of Photoshop CS6 and Lightroom 4 onto a newly purchased computer without having to reinstall all previous versions. I have been upgrading Photoshop since CS3 and Lightroom since Lightroom 2. What a pain if I