Compare physical db with CASE model

I'm using Designer Release 6.0 for PC. I'd like to compare (diff) my Designer db server model with my physical implementation
residing on our server. We sometimes have developers change the physical db without changing the CASE tool (ERD, tables, etc.). I
remember an old version of the CASE tool that had a report available that performed this compare. You run the report, login to your
physical db, then it would compare the CASE model with the physical model and give you an output of the differences. It would report
any column size/type changes, constraint changes, index changes - everything. I don't remember the name of the report but
I can't find a report title in this CASE version that sounds like this. Anyone know of such a report?
Thanks for any help,
Kevin Sharpe

Hi,
You can run the Reconcile Report when you run the Server model generator. In the Design editor select the Relational Table Definition node and open the Server Model Generator. You must choose to generate to the livedatabase rather than generate the DDL files.
The generator does not automatically execute the DDL it creates. Once the generator has created the DDL it also creates the Reconcile Report and brings up a dialog allowing you to view the DDL, execute the DDL, examine the report or cancel. The report comapres the physical database and the table definitions.
If you examine the DDL you'll see that the generator creates ALTER statements for any tables it finds in the database.
Hope this helps
Rgds
Susan
Oracle Designer Product Management

Similar Messages

  • Toshiba External USB Hard Drive 640GB physical interface inside case (model HDDR640E04Xx)

    Greetings all.  2 issues:
    1. Would like to know the physical interface of the hard drive inside the case of this Toshiba External USB drive (my model HDDR640E04XK for black case), whether SATA or IDE/ATA.  Of course, this isn't on the Toshiba website anywhere.
    2. Unable to locate a Tech Support link on the Toshiba site, to ask a tech by e-mail about the drive interface inside the case.  Does Toshiba not provide ANY tech support for their products??   (
    Any ideas fellow users?  Your help would be appreciated.

    This is a laptop forum. You probably want..
       Toshiba Hard Disk Drives
    -Jerry

  • Compare Physical model

    I am a new user here...
    I just created my first model in SQL Developer data modeler .... I have been happy so far....
    Question is: is there a way to compare physical model changes to Dataabase schema and generage DDL STMT?
    Scenario: I created a relational schema and physical model in data modeler and generaged DDL script which I ran in to new schema... and created a working environment... for the applcation.
    Now i made some Foreign key to initially defferred and saved data model. But when I compare this updated foreign key (physical model changes) changes to DB.... it doesn't show it being changed.
    I just want to know if I am missing anything here.
    Thank you in advance and please let me know if I need to provide any further information.
    Data modeler version: 3.1.1.703 ( just got new version to see if this one fixes my problem... but still not help)
    -R

    Thank you Philip for clarifying the functionality.
    Just wondering, is there a plan to support this functionality in near future?
    I am sure there are many users like me who created their data model using Data modeler and configured initial physical model properties..... and successfully created their database .... and also want to use this too to configure further chagnes in data model and have them merged with DB.....
    Thank you
    -Raj

  • Physical Inventory with serial numbers

    Hi friends,
    we are trying to post physical inventory with materials having serial numbers.
    However during post the system gives 2 errors.
    1)
    Stock data of serial number 2 not suitable for movement
    Message no. IO231
    "The current stock information for the serial number 2 contradicts the stock information of the movement to be posted... "
    2)
    Serial number 2 cannot be used here
    Message no. IO201
    "You have entered a serial number already present in the system..."
    Let me try to explain the situation.
    For example we have two storage locations.
    A material, say SERIAL, have some stocks in one storage location, say 0001, with serial numbers.
    Assume that in the system serial number 2 of the material SERIAL is in the storage location 0001.
    However, when physically counted, this serial number 2 shows up in the storage location 0002.
    Therefore we would like to enter count for the storage location 0002 to post the serial number 2.
    Doing so, we get the errors above.
    Is there any solution to that problem? Thanks in advance.
    Best regards,
    Yusuf

    Thank you Lakshman,
    yes the stock transfer between storage locations or removal first from storage location 0001 with pyhsical inverntory can be done in the system. However I wonder is there any better way to do this, without making any abap development.
    I would like to make a count for the storage location 0002 as in our case (or this can be a customer consigment either in another case). Here I expect the serial number 2 will be removed from storage location 0001 and will be placed in sorage location 0002 at the same time. Do you know any way of doing this?
    Best regards,
    Yusuf

  • Good iphone car mount that works with case?

    I need a car mount for my iPhone so that I can use the phone's GPS app. I've looked around and so far I can only find mounts that work for iPhones without any case.
    I would rather not have to remove the case everytime I got in my car, so are there any recommended mounts out there that work for phones with cases?
    Thanks!

    Griffin makes an FM/lighter mounted model, which has several bottom mounting brackets, to fit several phone models. I tested it out today, but the ipod buttons on the model don't work correctly, and FM was spotty to awful, as always on these type of setups. It did hold my naked cellphone well, and wish it had worked as advertised - cost about $100 at Best Buy.
    Belking has a similar model (about $70 at Best Buy), without the FM transmitter, also on a lighter stalk, which may work, since it grips the top of the phone with a wider clip, made to adapt to case thicknesses, I presume. I have not tried out this model, but may do so, since I have never found a single FM transmitter that works well - too much static, fading in and out, etc.
    Is there anyone who can recommend a lighter mounted (on a flexible stalk) charger for the iphone, that has a stalk long enough to accommodate any rental car, I would very much appreciate it.

  • FSCM SAP 5.0 Dispute Management-record and case model-dispute cas model.xml

    Hello,
    I am using the W21: Dipsute Management Building Block Configuration Guide.doc
    At the first step, creating a case record model, the configuration guide refers to a file:
    6.     In the toolbar of the Modeler in the upper middle section select Model >> Load local file and open the file - dispute case model.xml -.
    I do not have this file available, does anyone have any idea how to resolve this?
    -     How can I obtain this file
    -     Is this file necessary, to create a case record model
    Thanks for your help.
    Kind regards,
    Santiago

    Hi Santiago,
    This was tricky for me too.  Execute tran UDM_DISPUTE.  Change your RMS ID (left side, middle box, icon with two overlapping squares) to UDM_DISPUTE. In the same box, expand Record and Case Record Models.  Double click on Modeler for Case Records in Dispute Management.  This brings up a search box.  Click on execute Search. Double click on the Dispute Management entry in the lower box.  This gives you the standard model.  You can download this, using the Other Model Functions.
    Then change to your custom RMS ID (ex. ZUDM_DISPUTE).  Expand Record and Case Record Models.  Right click on Modeler for Case Records in Dispute Management and select Create.  Then upload the standard model into your RMS.  Then you can customize the model as you wish.  Hope that helps! 
    Beth

  • CLOB with case statement not working getting error

    Can anyone help on this
    I write this sql
    select Case when to_clob(PROPERTY) = 'is_intradesk=Y' then 'Internal' end
    from JPM_CP;
    Where PROPERTY column is clob column and its giving the error "ORA-00932: inconsistent datatypes: expected - got CLOB"
    Is it not possible to use clob columns with case or decode !

    Its working but it does not fulfill my purpose
    In you answer it is looking for position right! means, does the column contain the value('Intradesk=Y' ) or not. means
    I am looking for exact match with CLOB column values, that is Clob column(PROPERTY) contains the exact value that value which I am comparing with i.e 'Intradesk=Y'
    I need this
    select * from table where clob_column = 'value' (exact).
    Edited by: sajalkdas on Feb 4, 2011 3:28 PM

  • Help with CASE MANAGEMENT

    Hi Experts,
    I am working with Case Management, and I have to create Cases with all its specifications automatically. Anybody knows how I can create it? or Anybody have any suggestion or documentation to start with this.
    Thanks in advance.
    Regards,
    Beatriz.

    Hi,
    Easy transaction to Case Management customizing is SCASE_CUSTOMIZING. There you have an overview of the customizing of case management.
    Also carryon these steps one by one...
    Case Management Basic Settings :
    Define Number Range Intervals for Case
    Define Case Types
    Determine Permitted values for attribute
    Create values for "Category" attribute
    Create values for "Cause" attributes
    Create values for "Priority" attribute
    Create values for "Reason" for escalation attribute
    Assign escalation reasons to an attribute profile
    Create values for "Authorization level" attribute
    System Modifications
    Create status profile
    Create Text profile
    Create Text Ids
    Create Text Profile
    Define Logical system for external objects
    Enhanced System modifications
    Note About Enhanced System Modifications
    Define Processes
    Set up registry
    Create/Change Case Record Model
    Create Profiles
    Create attribute profile
    Create function profile
    Create terminology profile
    Create Activities for authorization check
    Activate application log
    Define processes
    Create/Change Case Record Model
    When u open the Transaction SCASE_CUSTOMIZING , there will be Registry Steps...
    Follow them step by step.
    For any queries reply.
    Regards,
    Eswari.

  • Still need help with case sensitive strings

    Hello guy! Sorry to trouble you with the same problem again,
    but i still need help!
    "I am trying to create a scrypt that will compare a String
    with an editable text that the user should type to match that
    String. I was able to do that, but the problem is that is not case
    sensitive, even with the adobe help telling me that strings are
    case sensitive. Do you guys know how to make that comparison match
    only if all the field has the right upper and lower case letters?
    on exitframe
    if field "t:texto1" = "Residencial Serra Verde"then
    go to next
    end if
    end
    |----> thats the one Im using!"
    There were 2 replys but both of them didnt work, and the
    second one even made the director crash, corrupting even previously
    files that had nothing to do with the initial problem..
    first solution given --
    If you put each item that you are comparing into a list, it
    magically
    makes it case sensitive. Just put list brackets around each
    item.
    on exitframe
    if [field "t:texto1"] = ["Residencial Serra Verde"] then
    go to next
    end if
    end
    Second solution given--
    The = operator is not case-sensitive when used on strings,
    but the < and > operators are case-sensitive.
    So another way to do this is to check if the string is
    neither greater than nor less than the target string:
    vExpected = "Residencial Serra Verde"
    vInput = field "t:texto 1"
    if vExpected < vInput then
    -- ignore
    else if vExpected > vInput then
    -- ignore
    else
    -- vExpected is a case-sensitive match for vInput
    go next
    end if
    So any new solutions??
    Thanks in advance!!
    joao rsm

    The first solution does in fact work and is probably the most
    efficient way
    of doing it. You can verify that it works by starting with a
    new director
    movie and adding a field named "t:texto1" into the cast with
    the text
    "Residencial Serra Verde" in the field. Next type the
    following command in
    the message window and press Enter
    put [field "t:texto1"] = ["Residencial Serra Verde"]
    You will see it return 1 which means True. Next, make the R
    in the field
    lower case and execute the command in the message window, it
    will return 0
    (true).
    Now that you know this works, you need to dig deeper in your
    code to find
    what the problem is. Any more info you can supply?

  • Comparing a value with NULL

    Hi,
    A funny thing is happening to me. Is it only in oracle 9i or in every version.
    I am working on a state project on Data Warehousing and faced a small BUG. Here is the sample code.
    DECLARE
    v_Var varchar2(10) := 'a';
    v_Null varchar2(10) := null;
    BEGIN
         IF v_Var != v_Null THEN
              DBMS_OUTPUT.PUT_LINE('First: Not equal');
         ELSE
              DBMS_OUTPUT.PUT_LINE('First: Equal');
         END IF;
         IF v_Var = v_Null THEN
              DBMS_OUTPUT.PUT_LINE('Second: Equal');
         ELSE
              DBMS_OUTPUT.PUT_LINE('Second: Not equal');
         END IF;
    END;
    This anonymous block should return Not Equal for both the statements, but unfortunately it returns Equal for the First and Not equal for the Second.
    Is this a BUG?
    Is this happening only in version 9i (I use version 9.2.0.1.0)?
    Any help/suggestion is appreciated.
    Thanks! :)
    Kamal Vala

    Thanks Justin! :)
    I got a clear answer from U.
    Appreciated.
    In this case I can go with the second statement as any way it returns Not equal
    Here is the modified actual statement which I am using in my procedure and now it works.
    I have modified the Inner IF by adding ELSE part, comparing with = (Earlier !=) and passing the variable assign to the ELSE part.
    -- compare old values with new values after checking the NULL values for Approver.
    IF (vc_Approver IS NULL) AND (v_Approver IS NULL) THEN
    -- Not passing value to keep the same value for v_RecInsert as the value is not changed.
    NULL;
    ELSE
    IF vc_Approver = v_Approver THEN
    -- Not passing value to keep the same value for v_RecInsert as the value is not changed.
    NULL;
    ELSE
    v_RecInsert := TRUE;
    END IF;
    END IF;
    Here if v_RecInsert is TRUE then I have insert the record.
    Hi Garcia,
    I can't use NVL function here as I have to pass a value for NULL and If that value really comes in the field.....than it will problem again.
    Thanks! to Justin and Garcia for taking ur time.
    Kamal Vala :)

  • Oracle Data Modeling tool interoperability with QDesigner models.

    Hello,
    Would it be possible to get some information on how Oracle SQL Developer Data Modeler works with models from other data modeling tools such as QDesigner.
    How can Quest QDesigner read the .cdm (conceptual data models) and the .pdm (physical data models) from QDesigner.
    Regards,
    Mary

    SQL Developer Data Modeler does not work with QDesigner models.
    Sue

  • Fan Runs With Case Open Bad Heat Sensor?

    I have an HP Pavilion 670y. I have a fan that runs for long periods of time and then stops and then starts again.  I decided to run my computer with the case open to make sure which fan was running before buying a new power supply if it was that fan.  Found it was the lower fan. The fan has less stops and starts with the case open but still has periods where it runs for a few minutes and then stops and starts.  Since I have the case open I can't see how the computer could be overhaeting.  Could it be a bad heat sensor?  If it is can the heat sensor be replaced or is it hardwired?
    This question was solved.
    View Solution.

    The HP support does not find a PC with that model number, however, units with a number of that nature of number are usually older units. 
    It is not clear as to what fan is considered the "lower fan".  The case fan may do as indicated, but a fan on the CPU or video card do not normally cycle.  Maybe include a picture? Click on the tree icon next to the chain "link" or ladder "video" icon to post a picture.
    {---------- Please click the "Thumbs Up" to say thanks for helping.
    Please click "Accept As Solution" if my help has solved your problem. ----------}
    This is a user supported forum. I am a volunteer and I do not work for HP.

  • Hi.  My new computer had Acrobat on it.  Suddenly, I was unable to open any PDF's.  and then I tried to update and was forwarded to the Adobe site that said I had to buy a monthly subscription.  I do not have the physical box with a serial number and was

    Hi.  My new computer had Acrobat on it.  Suddenly, I was unable to open any PDF's.  and then I tried to update and was forwarded to the Adobe site that said I had to buy a monthly subscription.  I do not have the physical box with a serial number and was going to buy the one advertised on the website until I discovered it's only for students and teachers, which I am not.  What should I do next as I need to use PDFs on a daily basis.  Thanks!  I would like to be able to download this and pay online.  Possible? I currently have Adobe Acrobat XI Pro.  I have a Windows 7 system.  Please help!

    As long as you know your serial number you can download PSE from here:
    Download Photoshop Elements products | 11, 10
    If you don't know your serial number:
    Find your serial number quickly

  • SSRS report with tabular model – MDX query CoalesceEmpty function does not return the provided string value

    Hello everyone,
    I created following calculated member in MDX query. I am using it in one of the report parameter in dataset (single select dropdown list as report parameter).
    WITH MEMBER [Measures].[ParameterCaption] AS
    CoalesceEmpty([Customer].[National Account Code].CURRENTMEMBER.MEMBER_CAPTION,'None')
    I would like to display 'None' text at the top of the dropdown list values. So that when user selects 'None' then this parameter will not considered in MDX query else the selected National Account Code will be considered to filter report data. But,
    the above return blank/empty value for  [Customer].[National Account Code].&  member though I specified 'None' as text in CoalesceEmpty function. Any advice would be appreciated.
    Thanks, Ankit Shah
    Inkey Solutions, India.
    Microsoft Certified Business Management Solutions Professionals
    http://www.inkeysolutions.com/MicrosoftDynamicsCRM.html

    Hi Ankit,
    It seems that you issue had been solved in your another thread.
    http://social.msdn.microsoft.com/Forums/sqlserver/en-US/5a5becac-226f-428a-95b0-aaaa22733818/ssrs-report-with-tabular-model-create-a-dropdown-report-parameter-with-none-option-as-the-top?forum=sqlanalysisservices#0e51bf8c-a66c-4df5-a244-0147728fdfdb
    iif([Customer].[National Account Code].CURRENTMEMBER.MEMBER_CAPTION="","None",[Customer].[National
    Account Code].CURRENTMEMBER.MEMBER_CAPTION)
    I marked this reply as answer, it will benefit to other members who have the similar issue.
    Regards,
    Charlie Liao
    TechNet Community Support

  • SQL Developer with Data Modeler, No Design Menu Option

    Using SQL Developer 3.0.04 Build MAIN-04.34 with Data Modeler. I have created a logical design and wish to forward engineer this to a relational model.
    I cannot seem to find the Design Menu option to use the >> Engineer to Relational Model option which is available under the Design Menu on the Stand Alone version of SQL Developer Data Modeler.
    Have checked the following locations:
    Tools -> Data Modeler
    View -> Data Modeler
    File -> Data Modeler
    Right Click on my Logical Design
    I have ensure that all my entities have the Engineer To property set to a valid Relational Model.
    Is this a bug or am I missing a menu option / configuration setting?
    Thanks in advance for any help
    John

    Hi John,
    you can find ">> Engineer to Relational Mode" button among other buttons for logical diagram.
    Philip

Maybe you are looking for

  • RegisterAlarm - has anyone got this to work?

    I'm trying to get the registerAlarm function to work on a real phone, but it only works one time. I want the Midlet to be executed once every 30 sec, but after the first reschedule it stops rescheduling. Does anyone have a clue on what's wrong? I do

  • Won't display image

    Hi, I've been trying to get this code to show an image for quite some time and just don't understand why it isn't. I run the program and it just shows a black square on my marker. Is there something wrong with it? package {     import flash.display.B

  • I want to downgrade my iPhone 4 from 7.0.2 to 6.1.3.

    Hello,i have an iPhone 4 and i recently updated it to IOS 7.0.2 and it is moving slowly and i want to downgrade it to 6.1.3.Please somebody tell me how to downgrade my iPhone 4.Sorry for my english.

  • I get slow script message  how do stop this ?

    I get a slow script message how do I stop this ? I read to open terminal app. in utilities folder then cut and paste message to add debug but can't figure how to do that

  • Pl/sql Procedure is Not Creating With the CLOB data Type

    Hi, I am Using Oracle 10g Express Edition Release2.... My Doubt is While creating a table With CLOB Data Type the table is created successfully,but while Creating a Procedure With the CLOB Data type i am getting an Error Message 2667/5 PL/SQL: Statem