Control design

Hola ahora trabajo con labview 2013 pero no encuentro como instalar control design alguien sabe como hacer esto!
Solved!
Go to Solution.

Hola Laurentino...
En la resouesta anterior te envían la liga de descarga para la versión 2014, que por cierto, te recomiendo que descargues en lugar de la 2013, en fin; si deseas seguir en la versión anterior. 
La versión 2013 la puedes encontrar en la liga:
Control Design and Simulation Module
http://www.ni.com/download/labview-control-design-and-simulation-module-2013/4207/en/http://www.ni.c...
Exito

Similar Messages

  • (Control Design & Simulation) State-Space block doesn't give output

    I've tried and tried but can't get the State-Space block module to give me a graph / output.
    I have no idea what the problem is and hope that somebody can help me. The numbers and calculations work in Matlab (Simulink) but i can't get it to simulate in labview. 
    Anybody got any ideas?
    Solved!
    Go to Solution.
    Attachments:
    Cavities.vi ‏30 KB
    Matrixes.vi ‏27 KB

    The problem is that you are assuming that LabVIEW executes left to right. Dataflow doesn't work this way. Your code as this:
    does not tell LabVIEW that it has to execute everything from left to right. What is happening is that he is executing the 3 'island' of code in parallel and, in this case, it will have 'empty' values. You have to remove the local variables to make this work and dataflow paradigm will execute your code from left to right, as you want. here is the code:
    Also, one more thing. Your input to the "CD Linear Simulation" is all zero. That means that you are trying to input zero input to a linear system, which will give you a zero output to the response. You probably do not want that since zero as input doesn't give you any more information. If you want to see how to system goes to zero after initial conditions, you should use "CD Initial Response". Or you should modify the input signal to the system. Please study this shipping example to understand how to use Linear Simulation and Initial Response:
    C:\Program Files (x86)\National Instruments\LabVIEW 2012\examples\Control and Simulation\Control Design\Time Analysis\CDEx Time Domain Analysis.vi
    Hope this helps...
    Barp - Control and Simulation Group - LabVIEW R&D - National Instruments

  • Control design and simulation module

    Hi,
    I am new to Labview and i am trying to work on Control System design. I have downloaded and installed the Evaluation Module of Control Design and Simulation Module. The problem I am facing witht this is its not showing any control fuctions in functions Palette. While installing it said its installing only control design and simulation assistant. Please, can anyone help with this.
    I am actually looking at this module to implement Sliding mode control for non linear systems. I would like to know if there are any examples to implement this??
    Thank You.

    Hello
    The problem is the following. The version of LabVIEW that you are using does not match the version of the evaluation version of LabVIEW Control Design and Simulation Module (CD&SIM). If that happens, the installer will not select the support files for your LabVIEW. If you download LabVIEW 2011, then you must install CD&SIM 2011.
    Now, the module in the current version does not have an example with sliding mode control. But using this module, you can easily implement the algorithms and simulation its result using the Control and Simulation Loop.
    Hope this helps.
    Barp - Control and Simulation Group - LabVIEW R&D - National Instruments

  • Control design and simulation palette

    Hi all
    I've recently installed LV 8.2 professional edition on my PC.
    Watching the function palette i've seen the sub-palette 'Control design and simulation' empty... Is it normal? Do i need some toolkit to see something in it?
    King regards
    I love the smell of napalm in the morning

    alij wrote:
    its because the main labview is install in c:\program files , but when you install the module it will install in programfiles(x86) ,that because the **bleep**ing bug in the installation and programmers , plz fixx this , i think you have to copy paste files into the main NI labview which is in program files not program files (x86)...
    If LabVIEW is installed in "c:\program files", it means that you installed LabVIEW 64bit. You should install LabVIEW 32bit, which will go to "c:\program files(x86)" and will be compatible with your toolkit.
    There is nothing wrong with the installer. You simply picked the wrong product.
    Do NOT copy files between the two mentioned folders. One is for 32bit applications and one is for 64bit applications (assuming you have a 64bit OS).
    The toolkit is not compatible with 64bit LabVIEW (Details).
    LabVIEW Champion . Do more with less code and in less time .

  • Control Design and Simulation Tutorial

    Hi
    I'm starting off with a coursework which requires use of the Control Design and Simulation functions. Before I ask any silly questions i'd like to see the hand on tutorial, it's referenced in this white paper.
    http://www.ni.com/white-paper/5855/en/
    However the ftp link to the tutorial doesn't work, does anyone else have an alternative link, or could supply the tutorial directly.
    I appreciate any assistance.
    Kind Regards
    Danny
    Solved!
    Go to Solution.

    Hmm, thanks. It must've been the proxy server in the office. Disabled and it downloaded it via the wifi.
    Thanks

  • Control Design and Simulation palette doesn't appear

    I'm using LabVIEW 2009 in Professional License. I've installed Control Design and Simulation Module with its all other required Toolkits. The problem is that Control Design and Simulation palette  doesn't appear in the Functions Palette in any VI. Please help me with that.
    Adeel Amin
    NED University of Engineering & Technology
    Solved!
    Go to Solution.

    If you run NI License Manager, Expand LabVIEW2009>Modules>Control Design and Simulation.Can you verify that you have that directory and what is the color of the cube right next to it?
    Andy Chang
    National Instruments
    LabVIEW Control Design and Simulation

  • Control, design and simulation

    Hello everybody,
    I am trying to run a simulation in Control Design and Simulation module. My simulation consists of various simulation systems. The subsystems are working as desired when run as separate units, but when I run the complete system, the subsystems fail to produce the output values. 
    I have not used any local variables or any discrete function vi inside a subsystem.
    Where am I wrong ? Any help would be much appreciated.

    I mean the indicators connected to various subsystems are inactive and don't produce any output values. I tried to find the error using the Error Cluster, but it didn't show any error. I am using LabVIEW 2011. I have attached the complete system including the subsystems. The individual systems are working fine. I changed the solver too, but the problem persisted. Please try to identify the error.
    Barp wrote:
    When you say: Fail to produce a output, what do you mean?
    On the right side of the Control and Simulation loop you have the 'Error Out' cluster. Create a control from it and see if you have an error. Also, which version of LabVIEW are you using?
    If this is not producing an error, then try to change the solver you are using. It would help if you could post your code (or at least pictures) of it.
    Attachments:
    Wind Turbine Integrated.7z ‏2240 KB

  • Control Design and Simulation and DAQ

    I'm learning Control Design and Simulations. I have some questions about it.
    1. For System Identification use, we can find the transfer function/model of the system by feeding data measurement from the system. But, how long data do we need to be sufficent for Identification System to estimate the model? Until the get saturated value (steady state)? or any other intervals? What if the system is unstable? How will Identification System Toolkit estimate that case?
    2. For connecting to hardware, we just connect the clock in the simulation loop to the hardware? And the simulation loop will simulate the blocks inside once it got the trigger/data from the DAQ? what about the step time and solver? Do they follow the timing from hardware? or they will run on their own supplied values/clock?if we use USB DAQ, we can't have any clock from it (as far as I know it's because USB connection is not that stable for clocking since it might be any jitters or delays.) So, how do we configure the timing parameter for USB DAQ?
    3. There is possibility to convert model in transfer function to state space, how do we know the states inside that conversion?
    Any helps would be great...
    Thanks in advance...

    Dear Chin ho,
    After going through your questions I found some documentation which will be useful for you. But I you still have more questions, you can reply me any time.
    1- About the data and amount of it I couldn't find any info but maybe you can use the new functions in LV version 2009 and find your answer.
    Estimating States of Nonlinear Stochastic State-Space Models with Extended Kalman Filters
    In previous versions of the LabVIEW Control Design and Simulation Module, you can use the Discrete Kalman Filter function and the Continuous Kalman Filter function to estimate the states of a linear discrete or linear continuous stochastic state-space model, respectively. In the LabVIEW 2009 Control Design and Simulation Module, you can use the Continuous Extended Kalman Filter function and the Discrete Extended Kalman Filter function to estimate the states of a nonlinear continuous or a nonlinear discrete stochastic state-space model, respectively.
    The Continuous Extended Kalman Filter function and the Discrete Extended Kalman Filter function estimate model states of a partially observable plant based on noisy measurements. First, use the SIM Discrete Nonlinear Plant Model template VI or the SIM Continuous Nonlinear Plant Model template VI, located in the labview\templates\Control and Simulation directory, to define the system model. Then use the the Discrete Nonlinear Noisy Plant function or the Continuous Nonlinear Noisy Plant function to simulate the discrete or continuous nonlinear model, respectively, with the addition of noise. Finally, use the Continuous Extended Kalman Filter function or the Discrete Extended Kalman Filter function to estimate the states of your model.
    The Continuous Extended Kalman Filter function and the Discrete Extended Kalman Filter function linearize the nonlinear system either by calculating a Jacobian matrix internally or by using an external Jacobian matrix that you define. Use the SIM Continuous Jacobians template VI or the SIM Discrete Jacobians template VI, located in the labview\templates\Control and Simulation directory, to define an external Jacobian matrix.
    Refer to the LabVIEW Control Design User Manual, accessible by navigating to the labview\manuals directory and opening CD_User_Manual.pdf, for more information about estimating the states of nonlinear stochastic state-space models with extended Kalman filters.
    2- I think that I found a pdf document about this part of your question which will be helpful. If you would like to give your email address, I can send it to you.
    3- About this part you can check the help function in LabVIEW when you open the "CD Convert Transfer function To State-space" function in your front panel.
    I pasted some info about the mathematic part below.
    The LabVIEW Control Design and Simulation Module provides tools to study the dynamics of systems described by linear time-invariant (LTI) continuous and discrete models. You can create deterministic state-space, transfer function, and zero-pole-gain models. You also can create stochastic state-space models and the second-order statistics noise models.  You can use these forms to describe both single-input single-output (SISO) and multiple-input multiple-output (MIMO) systems.
    Continuous transfer function and zero-pole-gain models use the s variable to define time, whereas discrete transfer function and zero-pole-gain models use the z variable to define time.  Continuous state-space models use the t variable to define time, whereas discrete state-space models use the k variable to define time. 
    Deterministic State-Space Model
    Continuous
    x(t) = Ax("t) + Bu(t)
    y(t) = Cx(t) + Du(t)
    Discrete
    x(k + 1) = Ax(k) + Bu(k)
    y(k) = Cx(k) + Du(k)
    Stochastic State-Space Model
    Continuous
    x(t) = Ax(t) + Bu(t) + Gw(t)
    y(t) = Cx(t) + Du(t) + Hw(t) + v(t)
    Discrete
    x(k + 1) = Ax(k) + Bu(k) + Gw(k)
    y(k) = Cx(k) + Du(k) + Hw(k) + v(k)
    Second-Order Statistics Noise Model
    Q = E{w . wT} – E{w} . ET{w}
    R = E{v . vT} – E{v} . ET{v}
    N = E{w . vT} – E{w} . ET{v}
    where
    t is continuous time.
    k is the model sampling time multiplied by the discrete time step, where the discrete time step equals 0, 1, 2, …
    x is the model state vector.
    u is the model input vector.
    y is the model output vector.
    w is the process noise vector.
    v is the measurement noise vector.
    A is an n × n state matrix of the given model.
    B is an n × m input matrix of the given model.
    C is an r × n output matrix of the given model.
    D is an r × m direct transmission matrix of the given model.
    n is the number of model states.
    m is the number of model inputs.
    r is the number of model outputs.
    G is a matrix relating w to the model states.
    H is a matrix relating w to the model outputs.
    Q is the auto-covariance matrix of w.
    R is the auto-covariance matrix of v.
    N is the cross-covariance matrix between w and v.
    E{} denotes the expected value or the mean of the enclosed term(s).

  • Table control designed by wizard greys out after pressing enter

    Dear Gurus
    I have implmeted a badi to show some data on vl02n in a extra tab inside a table control designed using table control wizard. I have caught sy-ucomm event to display corrsponding data on the table control  to what I am already sending from pbo of the screen everything is working fine beside just one thing. Initially all the rows of table control stays in editable mode but When I enter some record and hit enter the corresponding record is properly shown along with the record from pbo and enterd on the table control but beside the current row all the rows below it turn grey and I cannot enter any further data. Please help me out.
    Anurag
    Edited by: Anurag Jain on Sep 17, 2009 12:28 PM
    Edited by: Anurag Jain on Sep 17, 2009 12:29 PM
    Edited by: Anurag Jain on Sep 17, 2009 12:29 PM
    Edited by: Anurag Jain on Sep 17, 2009 12:29 PM

    Solved. The problem was with the sequence in which code was written for all table control in PBO module. PBO code sequence for table controls should be as per the sequence on screen.

  • Configuration error in PID synthesis step of control design assistant

    Hello,
            I am exploring an evaluation version of NI LabVIEW Control Design Assistant 2011. For  getting started with it ; I am using getting started tutorial provided in the labview signal express help. Upto the step of frequency domain analysis it is working fine ; but when I insert step called PID Synthesis it is showing me an error like...Configuration error -Sampling Time number is not the same...Though I have followed all the steps mentioned in the document sequentially why am I getting this error?..Please educate me in this regard.
    Best Regards.

    I am having the same issue trying to install EM Grid Control 10.1.0.2 on a 9.2.0.5 Repository on HP-UX platform. I am wondering if you have found a solution?
    Thanks,
    Dawit

  • Problem using PID toolkit and control design toolkit to design the closed loop system. (for DC motor closed loop)

    Hi, i have facing some problem during i upgrade a project. This project is an opened loop system, it only achieved up to controlling the speed of motor, detecting the speed of motor, and switching the direction of motor while controlling the motor (This motor is a 12 VDC motor).
    In order to improve the project, closed-loop dc motor control system will be implemented to correct the error of the motor's speed and maintaining the speed for the initial setting. I would like to use PID control method to do the closed loop system.
    I already installed the PID toolkit V8.2 and control design toolkit V2.1.2, and i'm using DAQ usb 6221, LabVIEW 8.5
    Below is my problem.
    http://img177.imageshack.us/my.php?image=howtocreatethesetpointnx2.jpg
    question: 1. How to generate a icon for set point? my setpoint is duty cycle...
                    2. How to feedback the output duty cycle to summing junction?
    below this is my basic concept
    http://img237.imageshack.us/my.php?image=closedloopbz5.jpg
    Problem 2:
    http://img357.imageshack.us/my.php?image=problem1yk2.jpg
    question: Why PID toolkit icon cannot wire to cd series.vi?
    Below is my original program...
    http://rapidshare.com/files/140538836/pwm_generate-final_PSMII.vi.html

    Hi Cyrus
    Have you had the opportunity to see our
    developer zone site on the PID toolkit? This article also has sample
    code at the bottom that may help you in developing your application. I
    have also linked below knowledge bases regarding setting a point
    profile and generating a PWM from a digital output line. 
    PID toolkit
    http://zone.ni.com/devzone/cda/tut/p/id/6440 
    How to generate a set point profile:
    http://digital.ni.com/public.nsf/allkb/125F27AC143B6AFD86256C2B0004A4DC?OpenDocument
     How to generate a PWM on a digital output line:
    http://digital.ni.com/public.nsf/allkb/1561D31534F07D608625727900391114?OpenDocument 
    Thank You
    Eric Reid
    Thank You
    Eric Reid
    National Instruments
    Motion R&D

  • LabVIEW Control Design can't multiply an improper TF with a proper TF

    I'm calculating a dynamic inversion where I need to multiply two transfer functions,
    H = inv(G1)*G2.
    All transfer functions G1 G2 and H are proper. However, inv(G1) is improper. Even though the resulting H is proper LabVIEW's Control Design tool fails to perform the multiplication complaining that one of the systems is improper. Works fine in Matlab.

    Sorry, I forgot to add that I'm not using DAQmx, but doing it manually. I'm a beginner at this and am really stuck.
    I've attached my basic file to the post so you can have a little look, and a screenshot as you may not be able to open some parts of the file due to my non-popular DAQ board. Please note that the DA value is not required, as I'm using the control ouput instead of this, and that the chart has now been modified to show error vs controlk output.
    If I could get some help, I'd be extremely grateful.
    Attachments:
    2026_ReadSingleAD_LiteExperiment3Modded.vi ‏37 KB
    fd.JPG ‏122 KB

  • Mimo simulation in Control Design & simulation toolbox

    Hi,
    I am running is simulation with MIMO system represented as state space in control design and simulation toolkit. I see that I am not able to give vector with 2 inputs to the MIMO model. By default state space is represented by a SISO model. Can anybody guide how can one give two inputs to the state space model and run it as a MIMO system.
    Thanks and best regards,
    Amit Kalyani 

    You should be able to double click on the State-Space VI which will bring up State-Space Configuration Dialog Window. You will be able to use the drop down Polymorphic instance to selec a MIMO system. Or another way of doing this is to change the parameter source to Terminal, then wire in your MIMO model directly.
    Andy Chang
    National Instruments
    LabVIEW Control Design and Simulation

  • No lo puedo instalar labview 2011 Control Design and Simulation

    no e podido encontrar la verision para instalarlo agradezco si alguien me puede ayudar y guiar  en la instalacion 

    Hola, [email protected]
    Gracias por utilizar los foros de discusión, en el siguiente link puedes descargar el módulo LabVIEW Control Design and Simulation 2011.
    www.ni.com/download/labview-control-design-and-simulation-module-2011/2554/en/
    ¡Saludos!
    David P.
    National Instruments
    Ingeniería de Aplicaciones
    www.ni.com/soporte
    David P.
    National Instruments
    Applications Engineer
    www.ni.com/soporte

  • Control design & simulation

    Hi,
    How do I use LabVIEW Control Design & Simulation to run a DLL-file on a RT-target(CompactRIO)? It would also be great to know how much MB RAM it is required on the RT-target. 
    Thanks in advance

    One more bit of advice. You should really avoid using the feedback node on a simulation diagram. The feedback node will probably not behave like you want. The feedback node is fine outside the world of simulation. Use the memory block or the delay block from the simulation palette instead.
    Here's a brief explanation of why it's bad. The feedback node maintains its own state that the simulation knows nothing about. In your case, you are using the RK4 solver. The RK4 solver takes three minor steps and then a major step. This means the diagram is executed four times per major step. If you were using the feedback node to increment by 0.1 on each step, you'd be quite surprised to find the feeback node outputing 0.4 instead of 0.1 after the first step. Also, with variable step solvers like RK23, the solver may reject a step and start over from the last step. The built in simulation functions work with the solver to roll their state back. However, the feedback node cannot do this as it was not built to be used within a simulation. Its own internal state is already committed and cannot be rolled back if a step is rejected in the simulation.

  • LabVIEW Control Design and Simulation Module version 2013

    I have had Labview downloaded for quite some time now. Downloaded control design and simulation module. Installed it. When i go to use it in the
    functions menu, only the window appears. Opening it shows an empty window. I have attached a screenshot of the issue. Could someone please explain to me what the problem is and how I can go about fixing it?
    Attachments:
    Labview screenshot.docx ‏998 KB

    As Altenback said, It is very possible it expired or it needs activation. To see for sure, go to your "NI License Manager" and expand the Modules. you should see:
    If not green then you have to fix the license.
    Barp - Control and Simulation Group - LabVIEW R&D - National Instruments

Maybe you are looking for

  • How to pass an argument to a standalone java class in JDeveloper

    To the experienced: In JDeveloper when you write a java class with a main() method that takes no argument, you just right click the java file and select Run to run the program. But suppose the main() method takes arguments, how do you pass your argum

  • New HDR Image darker than preview

    Today I was using Adobe Bridge to combine sets of 3 photos with different exposures to create HDR images and sending them to Photoshop. So far today I made 20+ such images and successfully saved them into PSDs. I just ran into an odd problem. After c

  • Alphabetical  and Folder Issues

    Ok, let's look at one Event that I have set up and give me some input, correction or answers to the following real scenario if some of you would please. I have all the photos of my daughter from the various years of Easter, from 1998 to 2006. I have

  • Software update fail (5.1)

    Hello: I just received a new 3rd Generation AppleTV in exchange for a defective one.  It's currently running v 5.1 (5201) and keeps telling me there is new a software update for it but it always fails to do it.  I've restarted the unit a few times an

  • Mts_dispatchers

    I've setup a database (using the DBCA) set up with multi-threaded server (shared server) settings When I attempt to connect using 'SRVR=SHARED' in TNS_NAMES, I get an error: ORA-12519: TNS:no appropriate service handler found Here are my settings: mt