Corrupted serial data when reading

Hello Friends
Im working on a project that read a string through the serial port from a flow meter.
the string that the flow meter sends has this pattern. its a comma separated string:
0021,00029504,00032622,0115,0,0,00000000,00000006,​0000,00000000,00000000,0000,0,0,00000000,00000000,​18:14:48,12/04/12,2110,00000000,0
i already proccesed the data with this VI (please fell free to give me any suggestions ). Please see 1.jpg
I am having the following issue. when receving data from serial, several strings show up corrupted. please see good.jpg and bad.jpg. i have tried to read the serial data on hyperterminal, and all strings show up ok.
i will appreciate any suggestions and advises on how to fix this!
thanks in advance
Attachments:
1.JPG ‏71 KB
good.JPG ‏14 KB
bad.JPG ‏13 KB

moreins1 wrote:
hello
actually, i have one more question.
this is the data viewer i have on my vi. it shows each data string that my serial device is sending. this string will change 10 times in a second. this is OK. right now, its showing 1 string at a time:
0021,00029504,00030816,0110,0,0,00000000,00000009,​0000,00000000,00000000,0000,0,0,00000000,00000000,​18:14:54,12/04/12,2173,00000000,0
what i want now is to actually append all this data in the viewer so i can copy and pasted it to notepad. i would like it to show like this:
0021,00029504,00030816,0110,0,0,00000000,00000009,​0000,00000000,00000000,0000,0,0,00000000,00000000,​18:14:54,12/04/12,2173,00000000,0
0021,00029504,00031123,0107,0,0,00000000,00000009,​0000,00000000,00000000,0000,0,0,00000000,00000000,​18:14:54,12/04/12,2174,00000000,0
0021,00029504,00030948,0104,0,0,00000000,00000009,​0000,00000000,00000000,0000,0,0,00000000,00000000,​18:14:54,12/04/12,2175,00000000,0
0021,00029504,00030866,0103,0,0,00000000,00000009,​0000,00000000,00000000,0000,0,0,00000000,00000000,​18:14:55,12/04/12,2176,00000000,0
0021,00029504,00030903,0105,0,0,00000000,00000009,​0000,00000000,00000000,0000,0,0,00000000,00000000,​18:14:55,12/04/12,2177,00000000,0
0021,00029504,00030888,0105,0,0,00000000,00000009,​0000,00000000,00000000,0000,0,0,00000000,00000000,​18:14:55,12/04/12,2178,00000000,0
0021,00029504,00030836,0104,0,0,00000000,00000009,​0000,00000000,00000000,0000,0,0,00000000,00000000,​18:14:55,12/04/12,2179,00000000,0
0021,00029504,00030545,0095,0,0,00000000,00000009,​0000,00000000,00000000,0000,0,0,00000000,00000000,​18:14:55,12/04/12,2180,00000000,0
and so on.........
Can you please advise on how to do this without actually monkeying around with the VISA inicialize?
thanks!
You're gonna have to put that string into a shift register to bring it back around.  Then you'll have to concatenate it with the current string (add a return so they end up on different lines) and take the output to your indicator.  Be careful what you wish for... if it's updating 10 times a second, it will eat up memory like crazy.
[edit]
Didn't realize you wanted to cut n paste to notepad... why not just take the original output to a file instead of an indicator?  Cross beat me to it.
Bill
(Mid-Level minion.)
My support system ensures that I don't look totally incompetent.
Proud to say that I've progressed beyond knowing just enough to be dangerous. I now know enough to know that I have no clue about anything at all.

Similar Messages

  • Using Serial Port for Non-Serial Data Acquisiton

    I searched the forums and couldn't find anything related to this topic.
    I saw that it was possible to use the parallel port for simple digital I/O and I was hoping the serial port can be configured the same. It seems all the VISA VI's only want to use the serial port to recieve ASCII chars at a given baud rate, but is it possible to simply poll the status of the serial line at my own speed to see if it is high or low, kind of like a single pin DAQ?
    It seems it would be possible as long as the serial data is read and controlled by labview and not by Windows. Let me know if you have any ideas how to approach this problem, or any feedback as to why it is not possible.
    Thanks everyone!
    Solved!
    Go to Solution.

    Select Property>Serial Settings>Modem Line Settings. For example, the CTS State is an input to the pc.
    Using these lines is a very poor replacement for a scope or DAQ board. The only things you can get back is Asserted, Unasserted, or Unknown. The range of acceptable signals is quite large. Anything between +3 and -3 is an unknown state. Your other signals are +/3 to 15 volts. what kind of signals do you actually want to capture?
    edit: There is no such thing as VISA Status so I have no idea what you are actually using.
    Message Edited by Dennis Knutson on 07-20-2009 11:09 AM

  • I always lose data when i read continous using serial

    I am developping a application, using serial communication for data
    acquisition.
    This serial read data continuous.but when i click on the graph or made
    a zoom i lose data in that interval ...
    What can i do

    If I understand correctly what you're saying, there is a gap in you data when you click on the graph, or zoom in on it. If you have the acquisition and the graph in the same loop, you could be essentially pausing or slowing down the loop while you are interacting with the graph. I've never noticed this effect before myself, but it is possible.One solution might be to put the acquisition process in a seperate loop and pass data to the loop containing the graph in something like a queue.Mike...
    Certified Professional Instructor
    Certified LabVIEW Architect
    LabVIEW Champion
    "... after all, He's not a tame lion..."
    Be thinking ahead and mark your dance card for NI Week 2015 now: TS 6139 - Object Oriented First Steps

  • How to process other task when reading the data from a file?

    Hello,
    I met a problem. I created a GUI to control the audio data processing. When the "Start" button is pressed, a block of data is read from the audio file and processed, then loop.But other buttons or method cannot be operated in that procession until all data is processed.
    How to let the other methods work under that circumstance? Should I use multiple threads?
    The relative code:
    SourceDataLine line;
    boolean stop = false;
    // When press "Start" button, the following method is invoked:
    public void play(){
    line.start();
    int bytesRead = 0;
    byte[] dataBuf = new byte[7500];
    while (bytesRead != -1& !stop)
    try
    bytesRead = audioInputStream.read(dataBuf, 0, dataBuf.length);
    catch (IOException e)
    e.printStackTrace();
    if (bytesRead >= 0)
    int bytesWritten = line.write(dataBuf, 0, bytesRead);
    line.drain();
    // When press "stop" button, this method is invoked.
    public void stop(){
    stop = true;
    line.stop();
    // When press "***" button, the following button is invoked:
    public void ***(){
    Many thanks.Looking forward to getting your answer.

    You have to use a seperate thread :
    Wheb you press the start button, you have to make sure a seperate thread is started :
    Thread runner = new Thread(){
    public void run(){
    //Here comes your code which reads the file
    runner.start();
    KR,
    Jan

  • Error when reading data from socket

    Hi,
    I am getting the error 'NiRawReadError: An error occured when reading data from socket.' when using the ABAP API  'mo_core_service->invoke_matching'.
    And I get this error only when I pass ABAP_TRUE to the paramter 'iv_wait_for_invocation' .
    Can anybody help me in correcting this?

    Hi Narasa,
    The following error is already in discussion in the below forum.Plz consult the forum link you will find the error solution.
    Problem in ABAP API - NiRawReadError: error when reading data from socket
    Rgds
    Ankit

  • Error when reading the access data for the Adapter Engine

    We are getting the following error in XI. It started on Jan 22 and resolved on Jan 23 automatically. Nothing has been changed and we don't able to understand how problem started and how it resolved:
    <?xml version="1.0" encoding="UTF-8" standalone="yes" ?>
    - <!--  Call Adapter
      -->
    - <SAP:Error xmlns:SAP="http://sap.com/xi/XI/Message/30" xmlns:SOAP="http://schemas.xmlsoap.org/soap/envelope/" SOAP:mustUnderstand="1">
      <SAP:Category>XIServer</SAP:Category>
      <SAP:Code area="INTERNAL">AE_DETAILS_GET_ERROR</SAP:Code>
      <SAP:P1>af.xpd.dbcixpd</SAP:P1>
      <SAP:P2 />
      <SAP:P3 />
      <SAP:P4 />
      <SAP:AdditionalText>3: Unable to find URL for Adapter Engine af.xpd.dbcixpd</SAP:AdditionalText>
      <SAP:ApplicationFaultMessage namespace="" />
      <SAP:Stack>Error when reading the access data (URL, user, password) for the Adapter Engine af.xpd.dbcixpd</SAP:Stack>
      <SAP:Retry>N</SAP:Retry>
      </SAP:Error>
    Pls suggest if anyone has gone thru same problem.
    Regards
    Amar

    I got the same problem while using RFC lookup.
    <?xml version="1.0" encoding="UTF-8" standalone="yes" ?>
    - <!--  Call Adapter
      -->
    - <SAP:Error xmlns:SAP="http://sap.com/xi/XI/Message/30" xmlns:SOAP="http://schemas.xmlsoap.org/soap/envelope/" SOAP:mustUnderstand="">
      <SAP:Category>XIServer</SAP:Category>
      <SAP:Code area="INTERNAL">AE_DETAILS_GET_ERROR</SAP:Code>
      <SAP:P1>af.tx1.netweaver</SAP:P1>
      <SAP:P2 />
      <SAP:P3 />
      <SAP:P4 />
      <SAP:AdditionalText>3: Unable to find URL for Adapter Engine af.tx1.netweaver</SAP:AdditionalText>
      <SAP:ApplicationFaultMessage namespace="" />
      <SAP:Stack>Error when reading the access data (URL, user, password) for the Adapter Engine af.tx1.netweaver</SAP:Stack>
      <SAP:Retry>M</SAP:Retry>
      </SAP:Error>
    Any idea ,when we get this error usually.

  • "No more data to read from socket" exception when testing connections

    Hi,
    I will appriciate your help with the following problem.
    We have the follwoing errors in the weblogic.log (We are using weblogic 8.1.0.2 and Oracle 9.2.0.3)
    ####<Dec 20, 2006 10:47:49 AM EET> <Info> <JDBC> <ep> <mfserver> <Thread-14> <<WLS Kernel>> <> <BEA-001128> <Connection for pool "oraclePool" closed.>
    ####<Dec 20, 2006 10:47:49 AM EET> <Info> <JDBC> <ep > <mfserver> <Thread-14> <<WLS Kernel>> <> <BEA-001067> <Connection for pool "oraclePool" refreshed.>
    ####<Dec 20, 2006 10:47:51 AM EET> <Error> <JDBC> <ep > <mfserver> <Thread-14> <<WLS Kernel>> <> <BEA-001112> <Test "select count(*) from DUAL" set up for pool "oraclePool" failed with exception: "java.sql.SQLException: No more data to read from socket".>
    ####<Dec 20, 2006 10:47:51 AM EET> <Error> <JDBC> <ep > <mfserver> <Thread-14> <<WLS Kernel>> <> <BEA-001131> <Received an exception when closing a cached statement for the pool "oraclePool": java.sql.SQLException: Io exception: Broken pipe.>
    These exception occures every hour after the connection pool is being closed and refreshed.
    Also there are a lot of the follwoing warnning in the log :
    <BEA-001074><A JDBC pool connection leak was detected.
    Does these two problems connected? What can we do in order to solve it?
    Thanks
    Edited by RF123 at 01/28/2007 3:41 AM

    R F wrote:
    Hi,
    I will appriciate your help with the following problem.
    We have the follwoing errors in the weblogic.log (We are using weblogic 8.1.0.2 and Oracle 9.2.0.3)
    ####<Dec 20, 2006 10:47:49 AM EET> <Info> <JDBC> <ep> <mfserver> <Thread-14> <<WLS Kernel>
    <> <BEA-001128> <Connection for pool "oraclePool" closed.>
    ####<Dec 20, 2006 10:47:49 AM EET> <Info> <JDBC> <ep > <mfserver> <Thread-14> <<WLS Kernel>
    <> <BEA-001067> <Connection for pool "oraclePool" refreshed.>
    ####<Dec 20, 2006 10:47:51 AM EET> <Error> <JDBC> <ep > <mfserver> <Thread-14> <<WLS Kernel>
    <> <BEA-001112> <Test "select count(*) from DUAL" set up for pool "oraclePool" failed with exception:
    "java.sql.SQLException: No more data to read from socket".>
    ####<Dec 20, 2006 10:47:51 AM EET> <Error> <JDBC> <ep > <mfserver> <Thread-14> <<WLS Kernel>
    <> <BEA-001131> <Received an exception when closing a cached statement for the pool "oraclePool":
    java.sql.SQLException: Io exception: Broken pipe.>
    These exception occures every hour after the connection pool is being closed and refreshed.
    Also there are a lot of the follwoing warnning in the log :
    <BEA-001074><A JDBC pool connection leak was detected.
    Does these two problems connected? What can we do in order to solve it?Hi. The problems are not directly related, but may have the same cause.
    Something is killing your DBMS connections out from under the driver.
    Do you have a firewall between WLS and the DBMS, or a flakey network?
    Contact BEA support to get the 8.1sp2 patch for getting meaningful
    connection leak traces (CR209251_81sp2.jar). When that patch is installed
    the leak messages should show a full stack trace of the application code
    where the connection was obtained. It is that application code that
    somehow failed to close the pool connection, causing a pool leak. I
    suspect that the application code got an unexpected exception, such as
    when/if the DBMS/network/firewall killed a connection. In this case I
    believe the application went through an exception-handling path that
    forgot to close the connection.
    Joe

  • Error report:No more data to read from socket  when compile package

    We are going to migrate db from oracle 10g to oracle 11g. But when compile a package which is fine on oracle 10g, an exception "Error report:No more data to read from socket" throws on sql developer and break the connection. We have researched the issue and found if modify some code on a cursor, the issue will not happen.
    code:
    PROCEDURE DELETE_MANU_INTERV_BORROWS(
    p_borrow_id IN NUMBER,
    p_asset_id IN NUMBER,
    p_nsb_coll_type IN VARCHAR2,
    p_nsb_coll_code IN VARCHAR2,
    p_branch_code IN VARCHAR2,
    p_settle_date IN NUMBER,
    p_trans_type IN VARCHAR2,
    p_status OUT VARCHAR2,
    p_shorts_cursor OUT SYS_REFCURSOR
    IS
    var_end_settle_date GEC_IM_ORDER.SETTLE_DATE%type;
    CURSOR exist_allocation IS
    SELECT out_a.ALLOCATION_ID FROM
    GEC_ALLOCATION out_a,
    GEC_BORROW b,
    GEC_IM_ORDER o,
    GEC_TRADE_COUNTRY gc,
    (SELECT f.FUND_CD, f.BRANCH_CD, tc.TRADE_COUNTRY_CD, NVL(gc.COLLATERAL_CURRENCY_CD, gbk.COLLATERAL_CURRENCY_CD) as COLLATERAL_CURRENCY_CD
    FROM GEC_FUND f
    LEFT JOIN GEC_G1_BOOKING gbk ON f.fund_cd = gbk.fund_cd AND gbk.TRANSACTION_CD = 'G1L' AND gbk.POS_TYPE = 'NSB'
    LEFT JOIN GEC_G1_COLLATERAL gc ON gc.G1_BOOKING_ID = gbk.G1_BOOKING_ID
    LEFT JOIN GEC_TRADE_COUNTRY tc ON gc.TRADE_COUNTRY_CD = tc.TRADE_COUNTRY_CD
    ) loan_info
    WHERE b.BORROW_ID = out_a.BORROW_ID AND
    out_a.IM_ORDER_ID = o.IM_ORDER_ID AND
    o.FUND_CD = loan_info.FUND_CD AND
    o.ASSET_ID = p_asset_id AND
    gc.TRADE_COUNTRY_CD = o.TRADE_COUNTRY_CD AND
    o.TRANSACTION_CD = p_trans_type AND
    loan_info.COLLATERAL_CURRENCY_CD = p_nsb_coll_code AND
    loan_info.BRANCH_CD = p_branch_code AND
    o.SETTLE_DATE >= p_settle_date AND
    o.SETTLE_DATE <= var_end_settle_date AND
    b.STATUS = GEC_CONSTANTS_PKG.C_BORROW_MANUAL
    ORDER BY out_a.ALLOCATION_ID ASC
    FOR UPDATE OF out_a.ALLOCATION_ID;
    If delete the "OF out_a.ALLOCATION_ID" of the for update clause of CURSOR exist_allocation, this prolbem will not happen, and the code is comple succesfully on sql developer for oracle 10g.
    Does anybody have any idea? I've googled the similer problems but still can't find a clue. I'll appreciate any help.

    Welcome to the forum!
    Please provide the 4 digit Oracle version (result of SELECT * FROM V$VERSION) for the source and target servers; 10g and 11g are not versions. You also mention sql developer so what is the exact version you are using?
    >
    If delete the "OF out_a.ALLOCATION_ID" of the for update clause of CURSOR exist_allocation, this prolbem will not happen, and the code is comple succesfully on sql developer for oracle 10g.
    >
    Please clarify what works and what doesn't work because your statements are both incorrect and misleading.
    You can't delete the "OF out_a.ALLOCATION_ID" of the for update clause or you would get a syntax error by leaving FOR UPDATE OF with nothing specified after it.
    Also you original statement said
    >
    But when compile a package which is fine on oracle 10g
    >
    But now you say that if you delete the "OF..." the problem doesn't happen and the code compiles on 10g.
    Does the original code compile on 10g or not? Does it compile on 11g or not? After the original code is migrated to 11g does it compile? That is, the code is there can you manually compile it?

  • Reading and analyzing serial data

    Hello,
    My question is about interpreting periodic serial data.
    I'm trying to read a serial rs232 port, through which I'm receiving periodic data which is made up of 4 repeating messages.
    Each message consists of several parameters of various length and fomates (for example, the first parameter could be an unisgned byte while the second parameter could be a word-long float). Each message begins and terminates with known character sequences.
    I need to read this periodic data and display it to the user, so that each of the parameters (of which the messages are made) is displayed
    by a different indicator.
    Right now, I've used the basic read/write rs232 LabView tutorial but now I'm pretty much stuck...
    I've built a similar program using Visual Basic and I've started using LabView in order to build better user interfaces but so far I'm stuck...
    Any suggestions?

    First, I think you really could have come up with a better user name then falling asleep on your "N" key.
    Data that comes in through the serial port is a string.  So your problem really comes down to how to parse the string into its respective parts.  Look at the functions on the string pallete.  Functions such as Match String, Search/Split String, or Scan String for Tokens, should do what you need.  Once you have the parts broken up, the String to Number conversion functions would convert the strings into their appropriate datatypes.

  • Error when reading the DDIC-data for table

    Hi Tobias
    We upgraded from DMIS 2011 SP04 to SP07. We are in development system.
    To test initial load, we stopped replication for an existing table and then started replication for the same table.
    Mass transfer id connects ECC system to BW on HANA system.
    Replication errored with the following message:
    Error when reading the ddic-data for table MARD (RFC destination DWACLNT010).
    Looking for your guidance.
    Kind Regards
    Kamaljit Vilkhoo

    Was able to solve using oss note 1972533.

  • Error when reading the access data(URL,user, password) for Adapter Engine

    Hi,
    We are getting this error in production system 
    "SXMBSysErrorAlerts, Category INTERNAL, Error code: AE_DETAILS_GET_ERROR error text: Error when reading the access data (URL, user, password) for the Adapter Engine".
    Please tell what can be the cause of error. Where are the access data (URL, user, password) for the Adapter Engine read from?
    Its urgent.  We are in support project.
    regards,
    john

    Hi jhon,
              please check the following threads to resolve the problem.
    AE_DETAILS_GET_ERROR
    Error : no_adapter_engine_found: Unable to find Adapter Engine
    regards
    mahesh.

  • Error when reading the data of infoprovider

    Hello,
    I have a problem when excecuting the transaction 'listcube' on a specific infocube. It occurs an error message which complains problem when reading the data of the infoprovider. The message text sounds as follows:
    Error reading the data of InfoProvider ZDPPTGR1
    Message no. DBMAN305
    Diagnosis
    Errors occurred while reading a VirtualProvider outside the BI system. Check whether the previous error messages contain any information about the possible cause of this error.
    It is possible that the error message cannot be displayed because the error message class does not exist in the BI system. If this is the case, only the name of the error class and the message number are displayed. View the error message text in the specified error class in the source system of the VirtualProvider.
    Procedure
    Since the error is not necessarily in the BI system, there is no specific procedure for resolving it. With VirtualProviders, problems often occur with the connection to the remote system; these can lead to system termination. If the code for the VirtualProvider is not from SAP, contact the relevant contact person to help resolve the issue.
    If an SQL error is listed in the previous message, see the procedure for SQL errors.
    Has anybody experience with solving this problem? It sounds like a bigger problem - can somebody confirm this? Or is it a problem which is easy to solve?
    Thanks for answering!
    Kind regards
    Heinz

    Hi,
    Please follow the below threads. They are similar to the error you are facing and they may help you with the issue ::
    Remote cube - uncaught exception
    DBMAN350 Error reading MultiCube data over aggregate
    Error reading the data of InfoProvider 0TCT_VC01
    Regards,
    Arpit

  • No more data to read from socket when I try to open the control center

    Hi everybody,
    I'm using on production environment the following OWB:
    Client: 10.2.0.3.33
    Repository: 10.2.0.3.0
    The control center worked very fine since a week ago, and now suddently when I try to login from the Design Center I get the error "No more data to read from socket"
    I saw on the forum many thread relating the problem "No more data to read from socket", and my case is very close to the thread
    Warehouse Builder error no more data to read from socket.
    even if I'm using a different version of OWB...
    Now, I found on metalink the Doc ID: 549303.1 "*Opening of The Control Center Manager Fails with: No More Data To Read From Socket*" , where there are 2 solutions:
    1)This bug has been fixed in the Oracle 10.2.0.4 patchset and Oracle 11g database.
    2) To workaround the issue change the value of the parameter "optimizer_mode" from ALL_ROWS into FIRST_ROWS.
    In the thread above they found the solution setting the optimizer_mode=first_rows
    ....but I have two questions:
    1) I have another envinronment (development) completely equal to the production env. (same OWB versions), where the Control Center works perfectly and the optimizer_mode=ALL_ROWS
    Why in the development env., even if the optimizer_mode=ALL_ROWS, the control center works perfectly ???
    2) How it's possible that suddently the control center crashed with this error ? I didn't change nothing (at the Db level and at the OWB level)
    My last chance is to apply the Oracle 10.2.0.4 patchset, but I can't change the db version (actually I have 10.2.0.3.0)
    I will appreciate any suggestion
    Thanks in advance
    Alex

    This problem still exists in OWB 11g R2. I hit this same issue yesterday. Not sure why its claimed to be resolved

  • Do I use data when I read on my kindle app on my iPad

    Do I use data when I use my kindle app on my iPad

    You should only use data when you download the book. As I understand it your book is on your device and you read it from there. The only data usage I can think of is if you are doing their 'sync your book across your devices' then Device one would have to tell Device two 'she's on page 49 now'

  • Error when reading data from XML using JAXB?

    Hi all,
    I get the error message when reading data from XML using JAXB.
    [org.xml.sax.SAXParseException: The entity name must immediately follow the '&' in the entity reference.]
         at javax.xml.bind.helpers.AbstractUnmarshallerImpl.createUnmarshalException
    (AbstractUnmarshallerImpl.java:315)
         at com.sun.xml.internal.bind.v2.runtime.unmarshaller.UnmarshallerImpl.createUnmarshalException(UnmarshallerImpl.java:481)
         at com.sun.xml.internal.bind.v2.runtime.unmarshaller.UnmarshallerImpl.unmarshal0(UnmarshallerImpl.java:199)
         at com.sun.xml.internal.bind.v2.runtime.unmarshaller.UnmarshallerImpl.unmarshal(UnmarshallerImpl.java:168)
         at javax.xml.bind.helpers.AbstractUnmarshallerImpl.unmarshal(AbstractUnmarshallerImpl.java:137)
         at javax.xml.bind.helpers.AbstractUnmarshallerImpl.unmarshal(AbstractUnmarshallerImpl.java:142)
    I don't find the reason, please help!
    Thanks in advance!

    The problem is sovled.

Maybe you are looking for

  • Mini-DVI to VGA supports PowerBook G4 only?

    Hello everyone, I just bought an LCD TV with a VGA port which allows you to use it as a computer monitor. I lost my mini-DVI to VGA that came with my computer, (iBook G4), and I was planning on buying one. However, when look at the specs on the websi

  • Using UTL_DBWS to contact IIS hosted Web Service

    Hello- A generous No-Prize to anyone with insight on this issue... I am using UTL_DBWS to contact an IIS hosted web service, relevant code here: FUNCTION call_gnr ( p_name IN varchar2 ) return varchar2 IS l_wsdl_url varchar2 ( 1024 ) := 'http://local

  • G4 Cube & ViewSonic LCD TV ?

    I have a 450MHz Cube that i would like to hook up to this TV http://www.viewsonic.com/products/lcdtv/NX2232w/#specs Do i have to upgrade the video card to this? http://cgi.ebay.com/ws/eBayISAPI.dll?ViewItem&rd=1&item=280171012505&ssPageName= STRK:MEW

  • CUP Server Not Responding

    Hi, I have been trying to use Command line utilities to access my CMSDK server. I did the basic three variable setting in the ifscmdline. I started the ifshell but it's just hanging. So how can I see whether CUP server is UP or not, Is it possible to

  • Email from Service Notification

    Dear Friends, There is a requirement to trigger an email from the service notification. In the standard SAP, I have seen a standard action box setting but I can't have this setting in the template am following. Could you please suggest any other sett