Deploying applicatio​n using pci-8532

I am trying try deploy an application that uses a cDAQ-9178 and a PCI-8532 Devicenet (version 2.0.2). The built application work fine on the developement system, but on the deployed system it hangs for ~45 seconds before giving an error (see attachment). What am I missing?
I also moved the project to another development system and had to setup  the DAQmx names (no problem with MAX) but in the project manager I had to set up the global variable for the bits on the DeviceNet board that I use and setup the auto deployment on startup - how does that happen on the deployed application when there is no project manager?
Attachments:
error screen.jpg ‏128 KB

I was mistaken when I moved the project the the setup did move ok. I think at the time I created a new project.
My latest problem now. The target machine is a windows 7 machine which the runtime did not work on. We installed the development package on the target machine and the project runs as expected - good. But the built exe that was built on that machine from the project that runs on that machine does not run as an exe. Also the exe that was built before and runs on the xp development machine also does not run on the windows 7 machine with a different error code now. Attached is the new error from the windows 7 target machine once the development package was installed,
Attachments:
error screen 2.jpg ‏119 KB

Similar Messages

  • Using PCI-8532 with NI-DNET 1.6.6 / NI-DNET 2.0.2

    I have a test fixture PC with the following configuration:
    PCI-8532 DeviceNet card
    Windows 7 Enterprise, SP 1
    LabVIEW 2010 Runtime
    NI-DNET 1.6.6 with MAX 5.0
    No LabVIEW development environment
    PCI-8532  is not available in MAX and the Windows Device Manager shows the card as 'PCI Device' with exclamation mark.
    Here is a screen shot of the Windows Device Manager and MAX:
    I cannot install the NI-Industrial Communication for DeviceNet 2.0.2 on this computer because I am getting the following error:
    Well, I have two questions
    How can I install and use the PCI-8532 and see it with NI-DNET 1.6.6? If this is not possible:
    How can I create an executable on my development system (laptop) with LabVIEW 2010 or LabVIEW 2011 and start this executable on the test fixture. Currently on my development system I have:
    LabVIEW 2010 and LabVIEW 2011 professional
    NI-DNET 1.6.6
    No NI hardware at all
    Do I need to install the NI-Industrial Communications for DeviceNet 2.0.2 on my laptop (my development system)
    Will this interfere with my current NI-DNET 1.6.6 and can I select which driver to use at compilation time
    Thanks,
    Nick
    Solved!
    Go to Solution.

    Hy Nick,
    No, it is defenitely not a replacement yet and I will work with our Web Department to make that more clear on our web page.
    The development for the new API is pretty much done but based on your feedback we are thinking of improving the compatibility so you could for example use the old 1.6.x APi and the new 8532 APi on the same machine, so you could use old and new hardware on that same machine. Would that be important for you?
    For now we are planning to allow only one hardware type at the same machine to save some development time. Let me know what you think.
    To clarify the today situation: The InCOM for Devicenet  component is not a part of LabVIEW. It is just a very simple way of communication with IO variables and function blocks for EM. The driver should install just fine even without LV installed. The error message is pretty much a Bug on our side and the workaround would be to use the LV Installer builder to create a new Installer that can install the Incom Dnet 2.0.x driver without having Lv installed.
    And today you should be able to have both the 1.6.x and the 2.0.x driver installed in parallel and use the 1.6.x API with ypour old boards and the 2.0.x IO variable approach with your new board.
    I keep this post updated as soon as we have a stable Beta available I will post something.
    DirkW

  • Open DeviceNet interface error when TestStand call VIs of NI PCI-8532

    Hello,
    We use NI PCI-8532 was used as DeviceNet master to do functionality test with a slave (AC Drive).
    But when open DeviceNet interface, it happen the error.
    We can't find the solution and hope to find help from you.
    The basic sequence in TestStand is:
    1). Call "Open DeviceNet Interface.vi" to open interface and creat interface object.
         Interface(master) setting: interface name=dnet0, MAC ID=0, baudrate=125000bps
    2). Call "Open DeviceNet IO.vi" to creat DeviceNet IO object.
         Device(slave) setting: MAC ID=63
    3). Call "Operate DeviceNet Interface.vi" and operation code=start
    4). Call "Wait For State.vi"
    5). Call "Read DeviceNet IO.vi" to read data from IO object
    6). Call "Close Object.vi" to close IO object handle
    7). Call "Close Object.vi" to close interface object handle
    Remark, these DeviceNet VIs locates at "C:\Program Files\National Instruments\LabVIEW 2012\vi.lib\DeviceNet\VIAPI".
    First time to run sequece in TestStand, it can pass to run step 1) to open DeviceNet interface.
    But once there is some error with these steps, and it will happen "Open DeviceNet Interface" error (error code=0xBFF62006) when run these steps again.
    Then even use LabVIEW DeviceNet example to test, and it happen the same error except restart computer.
    The DeviceNet example locates at "C:\Program Files\National Instruments\LabVIEW 2012\examples\NI-Industrial Communications for DeviceNet\Basic Examples\PXI & PCI\MixedCommunication.vi".
    Some information more:
    PC operate system: Windows XP SP3
    LabVIEW version: 2012 SP1
    TestStand version: 2012 SP1
    PCI 8532 driver version: 2.3.0
    Other installed PCI board: PCI 8531 CANOpen

    The following errors may be resolved by resetting the CAN, DeviceNET or LIN device:
    Error -1074388986 occurred at ...
    NI-CAN:  (Hex 0xBFF62006) The object is already open in another application.  Solutions: Ensure that only one application at a time uses an object , and that you close all objects prior to exiting your application (don't use LabVIEW toolbar's Abort button).
    Error -1074388969 occurred at ...
    NI-CAN: (Hex 0xBFF62017) This attribute's value must be provided prior to the Open. Solutions: Set the attribute using the Config function before the Open, and do not set the attribute at any later time; Do not configure multiple CAN Objects for the same ID.
    SO,you should reset the DeviceNet.
    And another similar issue can explain some points of your problem  http://digital.ni.com/public.nsf/allkb/7D9383E9BEAD0B21862571640002F687?OpenDocument

  • Ni-PCI 8532 card Pinout Explanation

    Hi,
    I am new to using the NI-PCI 8532 card. I am trying to attach a solenoid valve manifold to this card. On the PCI 8532 card pinout, pin 2 is called "V- (CAN reference ground)". I am confused as to why this pin is called V- but the description is that it is the reference ground. Is there a voltage associated with this pin?  What does this pin do?
    The solenoid manifold pinout is as follows
    1. Shield
    2. V+ (power supply)
    3. V- (power supply)
    4. CAN_H
    5.  CAN_L
    Do I connect the V- of the solenoid manifold to the V-  (Pin2) on the PCI card? (The pinout for the card is attached).
    Thank you
    Attachments:
    NiPCI8532_Pinout.png ‏42 KB

    Hi Jm, 
    That pin is just where it connects to the bus power supply. The can bus requires a power supply of 10-30V applied to those two pins. 
    I would have to set it up quickly to check, but I believe the PXI devicenet doesn't need external power and can power the bus itself. if it does you don't have to worry about those pins. 
    On devices that don't, you just have to make sure the pins are wired to the power on the bus before the devices will work. 
    There should be additional information in the Devicenet, CAN and CANopen manuals/help. 
    Jesse Dennis
    Design Engineer
    Erdos Miller

  • No ISA slot available in PC. How can I use PCI-85 Modbus Plus card with Lookout?

    My application is to communicate with two Modicon PLCs using Modicon's ModBus Plus (PCI based PCI-85) network card inside my PC, and using Lookout as an SCADA software. Since there is no ISA slot available in new PCs, I can not use Modicon's ISA-85 Modbus Plus networc card. But Lookout does not support PCI based PCI-85 card, how can I use PCI-85 card then, with Lookout? Why doesn't Lookout support it? I asked the following question from from the Modicon's representative about it:
    If I purchase Modbus Plus Driver Suite CD (SWMXDS001, 05, or 10 etc),will I be able to use Lookout SCADA software (by the way, it supports standard MB+ prtocol) for my application? If yes, can I use any version of an
    y of the ISA, PCI, or PCMCIA based MB+ card?
    His answer was:
    The Modbus Plus Driver Suite will talk to any version of card, PCMCIA, ISA, and PCI. The question now is will the SCADA package you are
    planning on using be able to talk to the Modbus Plus Driver Suite? You must contact National Instruments and ask them if they support Modbus Plus, and if
    they used the MB+ system developement kit to develop their product. Or if they wrote their own MB+ drivers, do they work with Modicon hardware?

    Hi,
    currently Lookout does not support the PCI-85 card. The only card supported for Modbus Plus is SA-85. Please see for further information:
    Where can I Find Drivers for Communicating to PLCs, RTUs, and Other Industrial Hardware?
    How to configure the SA-85 card for Modbus Plus
    Hope this helps
    Roland

  • Unknown site error while deploying web services using OC4J

    Hi,
    I have been testing the deploying webservices examples using demo.zip on OTN site.
    I have trouble in binding the web application name to stand alone OC4J.
    I am running stand alone OC4J server fine. I verified the website http://localhost:8888, which is running fine.
    If I issue the command
    java -jar admin.jar ormi://localhost:23791 admin password1 -bindwebapp demo_ejb_web_service HelloService_web http://localhost:8888/ sejb_webservices
    I get error
    oracle.oc4j.admin.internal.DeployerException: Unknown site: http://localhost:8888/
    What is the http-web-site address that needs to be given for binding web app, if I am running local standalone OC4J with no default port changes?
    Thanks,
    Mohan

    Eric,
    Thanks for the response. But, still I am not able to bind web-application to OC4J.
    Here is how my server.xml has defined the web-site tag:
    <web-site default="true" path="./http-web-site.xml" />
    My http-web-site.xml has following web-site tag:
    <web-site port="8888" display-name="OC4J 10g (10.0.2) HTTP Web Site">
    <default-web-app application="default" name="defaultWebApp"/>
    <web-app application="default" name="dms0" root="/dms0" access-log="false" />
    <web-app application="default" name="dms0" root="/dmsoc4j" access-log="false" />
    <web-app application="default" name="admin_web" root="/adminoc4j"/>
    <access-log path="../log/http-web-access.log"/>
    </web-site>
    I used the following command to bind the example web service:
    java -jar c:\XtendTools\oc4j\j2ee\home\admin.jar ormi://localhost admin password1 -bindWebApp demo_ejb_service HelloService_web default-web-site /sejb_services
    I get "oracle.oc4j.admin.internal.DeployerException: Unknown site: default-web-site" error.
    I tried to use following names as http-web-site, but nothing works.
    "http://localhost:8888"
    "dms0"
    "adminoc4j"
    I downloaded stand alone OC4J 10.1.2 from OTN and tried these samples.
    Your help will be appreciated.
    Thanks,
    Mohan

  • HT3529 I am currently deployed and was using my iMessage to be able to talk to family back in the states and my iMessage stopped working. It will no longer select my number to use as the send/receive. How do I fix this so I can continue to talk to family?

    I am currently deployed and was using my iMessage to be able to talk to family back in the states and my iMessage stopped working. It will no longer select my number to use as the send/receive. How do I fix this so I can continue to talk to family?

    Read here:
    http://support.apple.com/kb/TS2755

  • Avoiding creation of DBlink during deployment of mappings using OMBPlus

    Hi
    we are facing an issue in our OWB 11g R2 (upgraded to patchset 10185523)
    We are deploying the mappings using OMBPlus like so
    OMBCREATE TRANSIENT DEPLOYMENT_ACTION_PLAN 'DEPLOY_PLAN' ADD ACTION '$object_type_DEPLOY' SET PROPERTIES (OPERATION)VALUES ('CREATE') SET REFERENCE $object_type '$objname'
    OMBDEPLOY DEPLOYMENT_ACTION_PLAN 'DEPLOY_PLAN'
    set OMBCONTINUE_ON_ERROR true
    OMBDROP DEPLOYMENT_ACTION_PLAN 'DEPLOY_PLAN'
    OMBCOMMIT
    The $objname is any object(in this case a mapping) that we are deploying
    OMBPlus generates a script on OWB level to create the associated DBlink each time it deploys a mapping and we get an error
    INFORMATIONAL
    multiple rows found for select into statement
    DBlink_a Create Error ORA-02011: duplicate database link name
    But the mapping deploys fine.
    Any tips how we can avoid creation of dblinks from OMBPlus whilst deploying our mappings only?
    Any help will be appreciated
    Birdy
    Edited by: birdy on 22-Nov-2011 05:22

    I dont think that you can:
    "Deploying a mapping or a process flow includes these steps:
    •Generate the PL/SQL, SQL*Loader, or ABAP script, if necessary.
    •Register the required locations and deploy any required connectors. This ensures that the details of the physical locations and their connectors are available at runtime."
    http://www.comp.dit.ie/btierney/Oracle11gDoc/owb.111/b31278/concept_deploy.htm
    But error that you get is only informational so you dont have to worry about it.

  • I want to deploy an application using firefox but I don't want it set as default browser. I am using mozilla.cfg to lockdown firefox.

    I am deploying an application using firefox. I am using the mozilla.cfg file to lockdown firefox and I don't want firefox to be the default browser.

    Try the option to "Force Firefox to make itself the default" as shown in this article - http://kb.mozillazine.org/Default_browser
    Another possibility is your email application may be hard-coded to use IE.

  • Pulse Train Generation using PCI-MIO-16E-4

    I need to generate pulse trains of changing pulse widths using PCI-MIO-16E-4 daq card using Igor Pro.
    I have tried to use the CTR functions (but always keep getting errors and it doesn't work). I also used the general purpose counters (GPCTR functions) but cannot visualise them on a CRO. If someone can help in regards to the programming aspect, it will be greatly appreciated.
    Thanks
    Vakul

    Hi Vakul,
    Some questions that might help me to get you a solution.
    Are you using Traditional DAQ, or DAQmx and which versions are you using?
    What operating system are you running?
    When you say you can't visualize them on CRO, I assume that you are hooking the counter out to a cathode ray oscilloscope and can't see the pulse train?
    Are you going to need more than two different pulse widths for your pulse train?
    There are several online knowledge bases describing how to change the frequency of a pulse train on the fly.
    This link explains how to use software to create a new pulse width.
    http://digital.ni.com/public.nsf/websearch/7B1B0427C39FE33086256CEE00752133?OpenDocument
    This link discusses using frequency shift keying, which will only allow you to have 2 different pulse widths.
    http://digital.ni.com/public.nsf/websearch/EC1F089252F33B248625696E006FB6FC?OpenDocument
    I assume that you are writing this program to compile in Igor Pro using C. I can help you with the C code development, but don't know anything about the Igor Pro API.
    Please get back to me about those questions and let me know if you need further help.
    Michael Denton

  • How to use counter using PCI 6259

    Hello, users,
    I have a PCI 6259 board and use Labview 7.1.
    I'd like to repetitively count the photon signals at 10ms integration time. I want cumulative counts in every 1 sec (1000ms) (or 1 min (60000ms)) And I want to save counts into txt.file which is open in excel program.
    I am a beginner to use counter using PCI 6259 board.
    1. Could you explain default NI-DAQmx counter terminals, i.e., CTR 0 SRC, CTR 0 GATE, CTR 0 AUX, and CTR 0 OUT?
    2. How do I use them or how can I connect to count TTL pulse using PCI 6259?
    3. As I mention my purpose above, which example is the first step to start working my purpose?
    4. If you know good example, could you tell me about that?
    5. If anyone has labview example which is similar to my aim, could you give me some tips or your examples?
    Any hint, comment or advice would be appreciated.
    Thank you so much for your response.
    Leek2

    I have never used the PCI 6259 but have used counters many times with labview, the coding should be the same independent of the board.  What you want to do is finite buffered edge counting using a internal clock.  The best way to do this is to look at the examples programs and use the express vi to get started, then you can use this code to customize your program exactly as you need.
    To address your questions:
    1. CTR0 means "counter 0" the name of the physical resource sometimes listed at GPCTR0.  Each counter has 4 connections to the outside world:
    source "src"(for counting input TTL signals),
    gate (for synchronizing to external clocks and edges),
    out (for pulse-train out operations)
    and aux (specialty operations such as up/down counting and encoding)
    2.For event counting with internal clocking you will only use the src this is the input from the signal you wish to count (ie PMT discriminator for photon counting).
    3,4,5. Look at the count edge examples, there isn't one that does exactly what you want but I have done this with a 6602 (it has e counters) where I use one set of counters to set up a finite pulse train in your case 1000Hz with 1000 pulses, and another counter to edge count on an external pulse, with the source of this pulse routed from the out of the other counter.  Then you can start the task and read when 1000 samples are in the buffer (about 1 second later).
    Hope this helps,
    Paul
    Paul Falkenstein
    Coleman Technologies Inc.
    CLA, CPI, AIA-Vision
    Labview 4.0- 2013, RT, Vision, FPGA

  • Using PCI-6503 on Win NT 4.0, with NIDAQ 6.8 or 6.9, in a C++ program I found the following DLL Initialization error..

    "Initialization of the DLL C:\WINNT\System32\NIPALU.dll failed. The process is terminating abnormally"
    The card tests OK with MAX2.0 and if I open the test panel first and then compile the exe, it works. So what exactly is the initialization Im missing but happens in MAX ?? While using PCI-6503 with Windows NT 4.0 SP6, and NI-DAQ 6.8.1 or 6.9, is there any initialization that a C++ program needs to do before trying to write to DIO lines ? I have a program in C++ which works fine (writes and reads the DIO lines from PCI-6503) IF I run it after opening the test panel for PCI-6503 in MAX 2.0. Otherwise it gives the following error..
    "DLL Initialization failed
    Initialization of the dynamic link library C:\WINNT\System32\NIPALU.dll failed. The process is terminating abnormally."
    The PCI-6503 tests OK using either NI-DAQ 6.8.1 or 6.9 and I can read write to the DIO lines using the MAX2.0's test panel. Also my program works fine if before compiling the code I open the test panel for PCI-6503 in MAX2.0, so I suspect there is some initialization Im missing in my program. Can someone educate me more on this. Thanks.

    Are you using ComponentWorks++ or just the NI-DAQ C interface?

  • Deploying WAR file using IAS Test Drive edition...

    Hi:
    Is it okay to deploy a build using a WAR file instead of an EAR file? Is
    there any documentation for deploying WAR files? All the available docs and
    examples start with EAR files.
    Thanks,
    George

    Hi,
    A war file is okay if you are using servlets & JSP, WAR means Web Archive.
    So you can very well go ahead with a war file, incase you are thinking of EJB's
    then a .ear file will help you.
    Regards
    Raj
    George Sang wrote:
    Hi:
    Is it okay to deploy a build using a WAR file instead of an EAR file? Is
    there any documentation for deploying WAR files? All the available docs and
    examples start with EAR files.
    Thanks,
    George

  • HT2471 How can I tell if my g5 power mac quad(2006) uses PCIe or PCIx cards?

    Hello,
    I am purchasing a Pro Tools HD8 system, and I need to know if my g5 uses PCIe or PCIx cards? How do I find this out?
    Regards, Dean.

    Choose About this Mac from the Apple menu, click on More Info, and check the model identifier. If it's PowerMac11,2, the computer has PCI Express slots. If not, they're PCI-X.
    (76258)

  • Can i use PCI 6115 both as an output and input device simultaneosuly?

    I would like to use PCI 6115 data acquisition card from National Instruments for both generating a signal and then configure it for receiving the generated signal. I am using MATLAB program.I ran a program and it shows no error. But the results are not what I expected. Any help will be appreciated

    Hello,
    The PCI-6115 can receive and generate signals. It can actually do both at the same time. However, this depends on how it is programmed. Since you are using MATLAB, I do not know what I can do to help. Are you making calls to NIDAQ32.dll?
    Please post any follow questions or maybe some more information on what you are seeing.
    Best regards,
    Justin T.

Maybe you are looking for