Error in actual work
Dear gurus,
In my scenario, I am confirmaing my network activities by puting percentage in the confirmation screen,
which some times lead to a DECIMAL VALUES in actual work field.
therefore, when i save, the system gives me an error "Only 0 decimal places are permitted for unit of measure DAY".
How can change the setting so that system takes the decimal values for actual work????
Regards,
VDS
Hi,
Change '' Decimal Places'' to 2 under Display.
''Denominator " to 1 under Conversion
'' Decimal Place rounding'' to 2 under Conversion.
Also ensure you are changing it for TAG unit--Commercial name DAY
This should work.
Regards,
Similar Messages
-
Hi there,
I am using a thorlabs fw102B filterwheel. It's connected via USB (simulating COM port, that's what it says in MAX). The second device is a camera, also connected via USB. The application is running 24/7, at least that's what it's supposed to do. LabView version is 8.6.
The LabView code I wrote for this, was never really finished, meaning I totally ignored error handling in the first program version. That never bothered me, because the program ran for weeks and months without any problem. Whenever I had to reboot my system it was not LabViews fault, but I was changing something else.
Recently I was running into problems with the filterwheel (after a system reboot). However, I don't understand the error in the first place: The filterwheel is supposed to change position every 15 minutes, in between the camera is taking exposures, then the data is written to an ASCII-file (only ~156 kB). At first the error occured just once: the filterwheel was set to the wrong position for about 15 minutes, which might happen, as it is not really could in counting. A few days later it was in that wrong positon for one hour, so it didn't respond to the "move" order four times in a row. Finally I didn't move at all anymore. The error message I was getting is "0xFFFFFFF unkown status code". In my opinion the communcation to the filterwheel got lost somehow. I don't know a better explantion.
But why should it recover after some time?
The problem usually occured at night, when nobody is there to watch.
I investigated the behaviour in a second setup (see attachment). There is only the filterwheel connected. Through randomly unplugging the USB or power cable I was able to reproduce 'session handle is not valid', 'unkown status code' and 'session handle lost'. The program enters the 'true case', the session is to be closed and resetted, then it shall be reinitialized. This actually works as soon as the cables are reconnected. But why?
The close.vi still returns 'session handle is not valid', The reset.vi returns the same, but initialize.vi returns 'No Error' and the system works again.
What am I not getting here?
I read some threads here and somebody mentioned for another instrument/problem to use the 'reset' command twice. So I tried 'close-initialize', 'reset-reset-initialize', 'reset-initialize' but only 'close-reset-initialize' works (not surprising). Yet I still get the same errors (probe 1 and 2). Am I introducing more bugs without knowing than I fixed?
I AM CONFUSED.
Carsten
Attachments:
error_catch.png 273 KBHello Ulrich,
thank you for your answer. Concerning the dataflow I agree and it is what I usually do. Actually I follow the dataflow paradigm whenever there is no problem (the 'false case' in the screenshot):
“FW102x Initialize.vi” -> “FW102x Get Position.vi” -> “FW102x Set Position.vi”.
Whenever there is a mistake, this just doesn't work with these drivers. The sequence
“FW102x Initialize.vi” -> “FW102x Get Position.vi” -> ///error/// -> “FW102x Close.vi”, “FW102x Reset.vi” ;; “FW102x Initialize.vi”
will give me errors for “FW102x Close.vi”, “FW102x Reset.vi” and “FW102x Initialize.vi” reporting "session handle not valid". However, if I "bypass" the instrument handles directly from the first "Initialize" to "Close" and "Reset", they will report the same error, but the second "Initialize" will work again. I can even merge the first two frames and execute "Close" and "Reset" at the same time to do so. But whenever I try something else, e.g. do the 'correct' wiring, I am unable to close, reset or reinitialize. I have to restart LabView completely, to make the vi work again. So I guess the session is still hanging around somewhere in memory, but I can't access it anymore.
Surprisingly, wherever I put Probes on the data handle wires they show the correct "ASRL5::INSTR" (with or without correct wiring). But only the "Bypass" wire makes the vi work. Since you couldn't find the drivers in the driver network, I guess they might just run into problems, if an error occurs.
But thanks for your comment anyway. The problem is fixed for the moment. It's just that I prefer to actually know what I am doing here instead of producing some code I'd rather not show anyone.
Carsten -
Error Project Server 2010, % Complete, Work and Actual Work
Hi Everyone
I have a Project Server 2010 SP2 Environment, The farm contains 3 Servers.
1 WFE, 1WebApp, 1 BD. All servers in the farm are Windows Server 2008 R2 and the Data Base Server is SQL Server 2008 R2
The Context:
The Project Managers create the Project in Project Professional 2010 SP2 for support Annual Maintenance about a software, then the team members go to my tasks in PWA to create the task inside the stage in the project, then they put the actual work, then they
send the progress to his project manager.
So, the project manager goes to the approval page to approve two times, one, the task creation and two, the progress.
So far all ok but when the project manager open the Gantt in Project Professional 2010 SP2 , the task that the team member has sent appear with a 100 percent complete, but the work with 0 hours and the actual work with 0 hours too, being that should appear
with the hours the team member has sent, that is my problem.
This occur only with this project manger and his team member, all of others project managers in the platform don't report this issue.
I already have re open the project and re publish too
So , let me know if you have some idea about this issue.
Erick Gutiérrez PMI Membership #ID 2089740 MTCS - Microsoft Project Server Managing ProjectsOnly other ideas is to make sure the duration isn't 0, which would make it a milestone.
Have the resources, recall the timesheets and resubmit. Run it thru cycle again and see if they actual show up.
Finally, you can run SQL query and see where the data may be.
1) Check if status manager is who you think it is
2) Check if project shows actuals in sql. Doesn't explain why not showing in schedule.
cheers!
Michael Wharton, MVP, MBA, PMP, MCT, MCTS, MCSD, MCSE+I, MCDBA
Website http://www.WhartonComputer.com
Blog http://MyProjectExpert.com contains my field notes and SQL queries -
Ok, so this is my first post here and I am admittedly terrible at forums. Someone might say, "This was addressed in the ___________ thread by __________! Go read it!" --- that may be so but I've spent enough hours trying to google this problem into submission to no avail based on what is apparently working for others, so I would like a chance to get specific answers to specific questions that aren't from Mar 2011, etc.
So first of all, I'm confused by all the various Wine programs/apps/whatevers. I've seen Wine, Wineskin, Winery, Wine Bottler, and at this point I wouldn't be surprised if there are even more than that. What's the difference between all of these and how do they work with one another? What do I actually need to get windows programs working?
All of my google searches have led me to people giving out fish, but no one giving out fishing lessons. I'm not a pro at mac and windows and all that, but I'm a fairly bright individual who gets VERY frustrated, very quickly, when I don't understand the why and how of something I'm attempting.
I've also found "answers" where the person attempting to help starts off helpful enough, but degrades into the most archaic of techno-babble after about 5-6 sentences. On the other hand, I've watched tutorials on youtube where the poster decides to skip (apparently crucial) sections of the tutorial, and mutters such gems as: "... you might wanna have to run Wine first before you can do anything, cuz I think it has to configure it and set up a bunch of stuff"
O.o
A happy medium between techno-babble and the most basic of explanations would be ideal for me, and I'd imagine for others as well.
Here is a summarized history of my relationship with Wine:
Diablo II - I downloaded this awesome thing which ended up being... uh... I guess Diablo II in a Wineskin "wrapper". I'm not sure, all I know is that it's a D2 icon, and if I go to 'show package contents', it's got C drive, Program Files, et cetera inside of it. I double click it, it launches D2, and it works like a dream. <3
'Vanilla Install' - That's what I heard someone call it. It was the command/terminal style install using xquartz and xcode found at http://www.davidbaumgold.com/tutorials/wine-mac/. I followed every instruction to the letter, and got all the way to '$ sudo port install wine', at which point it started going smoothly, free from the possible error he described regarding the installation of xcode, and then just failed after I left the room to use the restroom and came back. Please don't ask me to repeat what the error was, because honestly, after reading more things on the interwebs, I'm confused as to why it's even necessary to go through all of that, so I'd rather not try that route again anyways, rendering the error message quite possibly irrelevant.
Wine + Wine Bottler - So I decided to try to seek out an easier method, as I know that one must exist that doesn't involve command lines. I found a video tutorial at http://www.youtube.com/watch?v=m0BBkISOcEA, and oh man would it be great if that method had actually worked. Again, I followed all instructions provided to procure my free fish, and at the point in the video where he declares that "xquarts or x11 will open" - it doesn't open. Nothing opens. I was trying to install Star Sonata, btw.
So here I am, thoroughly worn out, frustrated at all the random places Wine is installed on my mac now, and just want someone to explain it all, from top down, without getting toooooooo technical on me. I know that might be asking a lot...## I know that the poster has already found a solution, but the following is a possible answer for others that have similar issues.
For Winebottler, just go to their website and download it. Run the program. Choose .wine as your prefix (best choice) or whatever suits you best. You'll need a functional X11. If you can't use the one that comes with your mac, download the latest one from the website.
If your issue is one with Winebottler's Wine not running correctly due to X11, then you have a pretty ugly problem, although a simple upgrade is the best solution (Upgrade XQuartz.app).
http://www.davidbaumgold.com/tutorials/wine-mac/#part-1
The above website is the easiest way to get REAL wine on your computer. First of all, Wineskin WInery, etc. are NOT WINE. They are 3rd party apps that may use Wine or may have originally part of Wine, but they are no longer up to date with Wine. WineBottler is currently up to date with the stable releases of Wine (but not the maintenence releases).
For the website tutorial and to run Wine on your mac without using a thrid party app, you will need to know a few things.
First, you will need to know basic control of the command line. That means, sudo (you must know the administrator password to your computer), and the forms of cd (change directory).
Second, you will need Xcode. Download 4.2 (stable) or whatever other versions you want, but beware: It is over 1 GB, and you will need time for it to work.
Third, you will need to get MacPorts and configure it. The tutorial should have this data.
When you download wine (use sudo port install wine-devel for the latest development release of wine), it will first download a lot of dependencies. This will take a while. After that, it will download wine itself.
After obtaining wine, to run a program, open the terminal.app window.
cd desktop/XYZ/ZYZ\ WRQ
The above will first enter the desktop, then folder XYZ, then folder ZYZ WRQ. From here,
wine th11e.exe
Or whatever executable you are trying to open. (Using Subterranean Animism as my example).
It should, in theory, run the program. Watch the terminal for errors. If there is an X11 problem, then it's not wine acting up. If the app crashes or has other issues, check the Wine Application Database to see if your app is compatible with wine.
If you have any further questions or other things, feel free to reply; I may or may not get back to you, but there's a good chance that someone will come in eventually. Otherwise, the Wine Wiki should have some information. -
MAXL Errors in a Working Script
Hi All,Making the transistion to MAXL from ESSCMD under Essbase 6.2. I have a script that successfully builds two of my dimensions using the SQL interface from Oracle. What's strange is, even though the script works, mid-way through MAXL log file, the following error appears:9 - Essbase error encountered: [BuildDimFile:'test'] [1030001].Then at the end of the file, it states:51 - MaxL execution failed.Anyone have any idea why MAXL is reporting failure, when the script is actually working?
Is that this error?:##1003001 Duplicate Members From Same Dimension On Data Record, [%s] Records CompletedIf so, could it be that this error is not fatal and that maxl just doesn't know the difference between a fatal and non-fatal error?-z
-
Request 0 of type 38 failed with server error - but it worked anyway
I'm trying to modify the rights that a certain group has on a certain folder. When I modify the rights (in Assign Security in the CMC) and click OK, I get the error:
An error occurred at the server during security batch commit: Request 0 of type 38 failed with server error : You do not have sufficient rights to make the requested security changes
However, when I click cancel and View Security, I can see that the change actually worked. Why do I get this error? Is there some right that I need to be assigned in order to stop getting the error?
I'm logging in with a test ID that has the following rights on the folder:
Add objects to the folder
Copy objects to another folder
Delete instances
Delete objects
Edit objects
Reschedule instances
Schedule document to run
Schedule to destinations
Securely modify right inheritance settings
Securely modify rights users have to objects
View document instances
View objects
The test ID has the following rights on the group:
Add objects to the folder
Delete objects that the user owns
Edit objects that the user owns
View objects
We're using XI 3.1; I've gotten the error when testing this in both FP 1.6 and FP 2.3. Thanks for any help you can provide.I just realized that I need to correct what I said. The rights that the ID has to the group are as follows (more rights than I mentioned originally):
Add objects to the folder
Delete objects
Delete objects that the user owns
Edit objects
Edit objects that the user owns
Securely modify rights users have to objects
View objects -
Why does Photoshop CC 2014 install as a trial, instead of actually working?
Why does trying to update Photoshop CC result in Photoshop CC 2014 being installed as a trial (instead of actually working)?
Does anybody know?
And why can't I get ACR 8.5 for either CC or CS6?Sign in, activation, or connection errors | CC, CS6, CS5.5
Mylenium -
Does the Desktop Software v6 actually work for anyone?
I have been trying to get my desktop software to work, or more specifically to synchronize, for over two weeks now. I have tried all of the suggestions given me and still no luck. Does this program actually work for anyone?
KathrynB wrote:
9. see my posts in the thread "Unknown Error Reported" I really don't want to repeat it again to yet another person. I have tried getting help from Telus and have tried the "self-help" here, and have followed the directions in the other thread. I have been trying to get this sorted out for over two weeks and am very frustrated. I have never had a problem installing the software before or getting it set up.
If you have another thread already going, then there's really no reason to open a new one, is there? That just clutters up the forums and results in what exactly happened here...I saw your post, knew nothing but what you'd posted in this thread, and therefore had no way to know that all that other information is available in that other thread...I suggest you choose one thread to work in...you can use the "Report Inappropriate Content" link to ask the Mods to merge things together.
Good luck!
Occam's Razor nearly always applies when troubleshooting technology issues!
If anyone has been helpful to you, please show your appreciation by clicking the button inside of their post. Please click here and read, along with the threads to which it links, for helpful information to guide you as you proceed. I always recommend that you treat your BlackBerry like any other computing device, including using a regular backup schedule...click here for an article with instructions.
Join our BBM Channels
BSCF General Channel
PIN: C0001B7B4 Display/Scan Bar Code
Knowledge Base Updates
PIN: C0005A9AA Display/Scan Bar Code -
Import Excel with Import Wizard / Problem during the import of "Actual Work" column
Hello,
I am trying to import an Excel File (*.xlsx) to Project Server 2013 through Project Professional 2013 and Import Wizard.
I am having trouble when I try to include the column "Actual Work". After selecting the columnsmapping I am getting a strange error message saying that "The File cannot be oppened","Make sure, that the Filename and Path is right"
and some other strange messages concerning compatibility, although I am using the same File, which works perfectly without the "Actual Work" column.
I have tried as well with csv and the outcome was the same.
Any help is welcome!
Thank you in advance,
IoannisWhich DW are you using - DMX on Mac? It didn't have that
option. This is
not an Educational version issue - it's a Mac issue.
Murray --- ICQ 71997575
Adobe Community Expert
(If you *MUST* email me, don't LAUGH when you do so!)
==================
http://www.projectseven.com/go
- DW FAQs, Tutorials & Resources
http://www.dwfaq.com - DW FAQs,
Tutorials & Resources
==================
"Terry_Straehley" <[email protected]> wrote
in message
news:fm85u9$5ec$[email protected]..
> From a 11/06 post
> <<Hi, My Dreamweaver MX Education Version does NOT
have the Import to
> Excel
> option. I am using "Excel 2003 (11.6560.6568) SP2, Part
of Microsoft
> Office
> Professional Edition 2003". If I start with a blank page
in Dreamweaver,
> click
> on File, Import, I only have the options "XML into
Template", "Word HTML,
> and
> "Tabular Data". Does anyone know why I don't have the
"Import Excel" >>
>
> This was not answered in the thread I copied it from. I
have the same
> problem.
> Can some one answer the question?
> -
Hi
We are having SRM5.0.
Trying to create Contract. Workflow Without approval of contract(WS1400086)is activated and start conditions also no workflow activated.
Contract is created and getting message Contract created.
But when tried to release the contract it shows "Awaiting approval".
In Workflow log (SWI1)it shows error."Error when starting work item xxxx".
What could be the reason. Please let me know the solution if anyone of you come across such error.
Thanks in advance
JagadishMasa
It is maintained as General task already.
It seems the workflow task WS14000085 does not have definition.
When checked in SWDD for the above teask there are no steps defined for that workflow.
SAP says that we need to define and action for workflow WS14000085.
But what is the procedure to define the workflow.
I presume this is the standard workflow and it should be defined by default when it comes along with the SRM package.
Anyone of you know how to define the workflow and activate the same?
Regards
Jagadish -
How to show no. of actual working days in Payslip in case of +ve time mgt
Dear Experts,
We have a requirement of showing no. of actual working days in payslip, which should be Calendar Days-(Paid+Unpaid absence). I created an w/t 1WRD for actual working days. Our paid absence w/t is 2006 and unpaid absence is 2005 copied from /845 and /846 respectively, both the absences are included in absence valuation table and working fine in that respect. But issue is i wrote a small PCR for calculating actual working days like below:
ZWRD
NUM=TKSOLL Set
NUM-E 2005
NUM-E 2006
ADDWTE1WRD
But still its fetching full working days i.e. calendar days 30 or 31 not deducting paid or unpaid absence for a month.
Pls help, what else should i do.
Regards
TanSorry, i am unable to paste RT, but its exactly as below
01, April, 2011
1WRD Working days 30.00
2006 Paid Absence 2.00
02, May, 2011
1WRD Working days 31.00
2005 Unpaid Absence 1.00
regards
Tan -
How to fix an error (related to work schedule rule) in Time evaluation ?
Hi experts,
I am getting an error while running time evaluation - PT60.
Find the log
Log:TimeEvaluation General data
Schema ZM04 Time Evaluation Without Clock Times
00753402 Christoudas Natalie
Customizing error in work schedule rule 1 VM 01 5MTWTF Person rejected: 00753402
How to fix it? Its urgent.
Be assured of points for useful answers.
RajeshHi All,
I have checked work schedules and work sc. rules. everything looks fine. Reason being fine, same work schrdule rule, i.e. 5MTWTF is used for other employees, whose payroll area, personnel area, personnel subarea, employee group and employee subgroups are same.
Why it is throwing error for one employee 753402.
I am providing you more information. In table V_T569r, if u select recalculation category as time evaluation, it is mentioned as 01.01.2003. Initially, one action called "Conversion take on" has been maintained as on 01.03.2002, where employee had payroll area -99 (payroll irrelevant) and personnel subarea - DAYY.
Then on 17.03.2008, another action ran "Conversion initial reassignment" where payroll area changed to "MT - monthly", subarea changed to DAYF. At that time PDC recalculation date in infotype 0003 was 01.03.2002 which was before recalculation date, i.e. 01.01.2003.
Time evaluation was throwing 2 error messages. one was solved by changing PDC recaluation date to 17.03.2008. But other error related to work sc rule 1 VM 01 5MTWTF still occurs.
Can some body now provide some useful information?
Thanks
Rajesh -
Error while executing work flow
Hi all,
I have created a workflow with user decision and send mail steps. But when I execute the workflow it is generating an error saying - " Task started under workitem ID 71036(current status: Error) ".
When I see the workflow log--> list of technical details --> step history, the following errors I got
exception occured Error when starting work item 000000071038
Process node Error when processing node '0000000004' (ParForEach index 000000
create Error when creating a component of type 'Step'
create_WIM_Handle Error when creating a work item
create_via_wfm Error within method CL_SWF_RUN_WIM_FACTORY->CREATE_VIA_WFM
get_witype Unable to determine work item type for step at node 0000000004
get_task_handle Error when loading task
find_by_wfdwiz Task definition '' not found
Executing workflow item Work item 000000071038: Object FLOWITEM method EXECUTE cannot be executed
Executing workflow item Error when processing node '0000000004' (ParForEach index 000000)
But when I create the same workflow in another client and excute, it is working fine.
Can anybody look into this.
thanks & regards
KrisHi Suresh,
Thanks alot, problem solved to some extent. I need some other clarifications.
1. whether SAP_ALL and SAP_NEW profiles are mandatory for the user WF-BATCH or only SAP_ALL can solve our issue?
2.
Unless your workflows are not going to use Webflow functions, configuring "Maintain Web Server" is not required
as you said, what are webflow functions?
Please provide me information on these as Iam new to Workflows.
Thanks & regards,
Kris -
Error while creating Work Order
Hello Experts,
I am getting below error while creating work order via add-on named beas but the error seems to coming from SBO.
Please advise.
Thanks
DeepakHi,
Plz check this thread:
What does this error mean? -
Error while creating work order from purchase order
Dear All,
We are having a subcontracting scenario where we are creating a Work order from PO but getting the below error.
Error - "No master data assigned to partners-locations-product combination."
Done all the setting mentioned in the below thread but the error still persist.
Error in Generating Work order from Purchase Order
Any suggestions on which master data we need to check?
Thanks,
mahesh.Hi Mahesh
In the below transaction
/SCA/MFGCFG - Work Order Configuration
Can you maintain Master data Assigment properly
Valid From
Valid To
Active---Checked
Can you please list what you maintained
Regards
Vinod
Maybe you are looking for
-
Prompt for a username/password while accessing a resource in wls 6.0
Hi all, I want to restrict access to any resource on my weblogic server 6.0 and prompt for a user name and password before accessing any resource. I did this using weblogicurl.policy file in wls 5.1. I am not able to find out how to do this in 6.0. C
-
Doubt in Submit...return
Hi all, i am trying a simple program .See below REPORT Ztest. data: begin of itab occurs 0, za(3) type c, end of itab. export itab[] to memory id 'ZPARA'. submit ztestcall and return. write:/ itab-za. In the pgm ztestcall, i have written
-
If you unplug the headphones ipod does not stop the music. How do I fix this?
If you unplug the headphones ipod does not stop the music. How do I fix this? При отключении наушников ipod не останавливает музыку. Как это исправить?
-
Why is my Easy YouTube Video Downloader 7.0 not working?
Every time I try to download a YouTube video, I am redirected to a blank white page and no download initiates...
-
sometimes my imac says that there is no memory/space on the start up disc. Why is this?