Error in table control push buttons enhancement....
hi all,
iam creating a table control with some push buttons namely Insert, terminate in a enhancement while clicking terminate iam getting error message that
" Flow control: Entry SAPMIEQ0, * , * is missing in T185V " can any one help me to solve this issue.
Thanks in Advance.
Prem.
Even in sm30 also its not allowing me to maintain that T185V table. its taking me to VFBS transaction code.pls help me in this issue
Thanks
Prem.
Similar Messages
-
Table control in Screen Enhancement.
Hi Experts,
I have implemented QQMA0001 screen exit.
In that sub screen I created a table control for which I need to place 'DELETE' and 'INSERT' push buttons.
But the push buttons on the subscreen (Push buttons can not be created on sub screen) is not working it is giving error. Please suggest some other way to place push buttons...
Regarding,
Bala
Edited by: bala virupaksha on Jun 7, 2009 4:12 AMHello,
We cant place any UI elements within the Subscreen area ...But in Subscreen we can have Push buttns
Define them and assign Ok_Code for them ...Handle the Insert and Delete withint he PAI event as per the Ok_codes defines .
Regards -
Error during creation of push button on selection screen
Hi,
I wanted to create push buttons on selection screen,
Code:
DATA DB1 TYPE VBAP-WERKS.
DATA DB2 TYPE MARA-MATNR.
SELECT-OPTIONS : SPLANT FOR DB1,
SCLASS FOR DB2.
SELECTION-SCREEN: FUNCTION KEY 1,
FUNCTION KEY 2,
FUNCTION KEY 3.
INITIALIZATION.
DATA FUNCTXT TYPE SMP_DYNTXT.
CLEAR FUNCTXT.
DATA: FUNCTXT_01 TYPE SSCRFIELDS-FUNCTXT_01.
FUNCTXT-TEXT = 'DEL'.
SSCRFIELDS-FUNCTXT_01 = FUNCTXT.
CLEAR FUNCTXT.
FUNCTXT-TEXT = 'EDIT'.
SSCRFIELDS-FUNCTXT_02 = FUNCTXT.
CLEAR FUNCTXT.
FUNCTXT-TEXT = 'CRE'.
SSCRFIELDS-FUNCTXT_03 = FUNCTXT.
But during activating, I'm getting the error as : Field "SSCRFIELDS-FUNCTXT_01" is unknown. It is neither in one of the specified tables nor defined by "DATA" statement.
Please suggest solutions to overcome this error.
Regards
Darshan MSHi,
trans. for examples of selection screen : BIBS
regards
Fred -
Webdynpro FPM Table Control Toolbar Buttons
Dear Experts,
In Webdynpro FPM Configuration, Table control tool bar to be enhanced with custom buttons and it should call the custom web dynpro applications.
After adding the buttons, where we have to configure the FPM Event ID's and corresponding actions.
Please check and let me know.
Thanks & Regards,
Sunil KSHi Sunil,
You have to create enhancement implementation for your application configuration. Then you have to follow the below procedure for enhanceing the feeder class.
1. Create explicit enhancement for your feeder class by choosing spiral button in the class object toolbar, then it will provide pre,post and override method for your methods.
2. As per your requirement you need to add some action in your table control toolbar, for that you need to implement post exit for the GET_DEFINITION method.
3. Enhance your FPM application for adding the table control button and assign the created action in your feeder class and process the events in the post exit implementation of your PROCESS_EVENT method.
THanks & Regards
Praveen Gupta -
How to solve error in table control?
Hi expert,
I am a beginer in table control.
I have a problem.
I create a table control in that I use a search help for a column. Everything is normal if I enter a value into search help value and save .
There are two situation:
1. In the first time I save this document without value in this column. After that,I reopen this document and enter value by use F4-> a error .
2.I save table control with value in seach help value. But when I change value in search help, a same error act.
Immediately, I debug and see after pass POV, next PBO : after LOOP table control 2 times because in my table control have 2 record, a error happen.
I thank you so much with ur help.Hi,
Please check if you have done the following,
=> Have you looped at the internal table with respect to the table control
LOOP at itab WITH CONTROL TABLECONTROL.
ENDLOOP.
=>Check if you have done it both in the PBO and the PAI.
=> Check if your fields in the table control and the fields that you have been using in the program match.
=> Have you modified your database table fields and not regenerated the Table Maintanence Generator (TMG) after that? The database table will only contain the older fields if you havent regenerated the TMG and activated it. -
Conversion error in Table control for Negative values
hello all,
Iam using table control with 6 columns and in that columns values are coming from Ztable. and out of that one column is of value which is input/output field and having negative value's also.type of that column is DEC.
Now when i run the report dump occurs showing error message as COnversion Error.
I think its because of negative value even the in attributes of that column i had selected With Sign checkbox.
Now when i run the report then if in Ztable negative value is there then i want to display negative value in table control also.
Please suggest me...
<removed_by_moderator>
Thanking you.
Regards.
Edited by: Hemant Baviskar on Sep 10, 2008 3:07 PM
Edited by: Julius Bussche on Sep 10, 2008 1:13 PMHemant
Refer to following link:
Table Control : Conversion error
Thanks
Amol Lohade -
Invalid field format (screen error) on Table Control
Hello,
When selecting a line or multiple lines on a screen made by me(using a Table Control), I get Invalid field format (screen error). Debugging the code it sends the message when looping the internal table on PAI to check if there were values changed. Is there a reason why this error appears on this?
loop at it_values.
chain.
field pvalues-BEGDA.
module CHANGE_QUEUE.
endchain.
endloop.
Thanks.No need to loop to check whether data is changed after PBO, just check System Field SY-DATAR, it will be set to 'X' if any field was changed.
So the following code is enough;
IF SY-DATAR EQ 'X'.
PERFORM SAVE_DATA.
ENDIF.
Regards
Karthik D -
How To Sort the Table Through Push Buttons (ASC & Desc)???
Hi,
I am facing a problem with regard to 'Push Buttons' that I have created on
my Form. I want the 'Push Button' to sort the table with respect to a
specific column in 'Ascending order' on first push and then in 'Descending
order' on second push and then again in 'Ascending order' on third push and so
on...
please help me to achieve this
regards,
.Hello,
You could try something like this:
Declare
LC$Order Varchar2(128) := Get_Block_Property( 'EMP', ORDER_BY ) ;
Begin
If Instr( LC$Order, 'DESC' ) > 1 Then
Set_Block_Property( 'EMP', ORDER_BY, 'EMPNO ASC' ) ;
Else
Set_Block_Property( 'EMP', ORDER_BY, 'EMPNO DESC' ) ;
End if ;
Execute_Query ;
End ; Francois -
Error in table control while displaying data.
Hi All,
I m doing module pool programming using Table control.
I m using one table only and declared internal table like the database table.
When I m transferring data from internal table to Table control screen, I m getting error like.
<b>A conversion error occurred while the program was trying to
display data on the screen.</b>
The filed is of DEC type and it is having some value with negative sign.
Whether I have to change field type of sceen element and if so then to which data type?
Or any other way to handle such situation.
Thanx.
Umesh.Hello,
Please check whether the screen field name of the table control and the type
is same as the internal table that you are using to populate.
reward if helps
Thanks
Krishna
Message was edited by:
Krishnakumar Ramadoss -
Conversion error in table control
Hi expert,
Am using table control wizard to create table control in module pool proframming.
as per my internal table there are 15 fields n am only using 10 fields in table control.
is it mandatory that i need to keep all the fields in order as am dispalying it in the table control.
if yes then wat abt the remaining 5 fields. should keep these fields in the end of the internal table .
kindly assist
thx in advance.Hi...
If you have only 10 fields to be needed in program then why do you have those extra fields in your internal table. Remove them if no longer needed.
Else you can get them displayed and make those column inactive.
Regards,
Uma Dave -
Index of the Table control - No lead selection activated
Hi guys,
I have a table control where there is no lead selection.... One colum of the table contains push button on all rows and I need to find the row id based on the click of the which row button... How to do this???
regards,
PrabhuHi Prabhu ,
write the below piece of code in the button Action .
DATA lo_nd_node_table TYPE REF TO if_wd_context_node.
DATA lo_el_node_table TYPE REF TO if_wd_context_element.
DATA ls_node_table TYPE wd_this->Element_node_table.
* navigate from <CONTEXT> to <NODE_TABLE> via lead selection
lo_nd_node_table = wd_context->get_child_node( name = wd_this->wdctx_node_table ).
CALL METHOD wdevent->get_context_element
EXPORTING
name = 'CONTEXT_ELEMENT'
RECEIVING
value = lo_el_node_table. " getting the clicked line
CALL METHOD lo_nd_node_table->SET_LEAD_SELECTION
EXPORTING
ELEMENT = lo_el_node_table. " Setting the lead
data lv_index type i.
CALL METHOD lo_nd_node_table->GET_LEAD_SELECTION_INDEX
RECEIVING
INDEX = lv_index. " getting the index of the lead line
Hope it will Helpfull .
Regards
Chinnaiya P
Edited by: chinnaiya pandiyan on Jun 28, 2010 12:04 PM -
Crystal report Viewer Not Showing Control Bar Button Icons
Hi
I am using Crystal report along with .net 2003 in web application.
While executing, the report its not showing any errors,but the control bar buttons(print, export, next page last page, previous page, first page, etc ) are showing without there icons.
These invisible buttons can be found by placing the mouse over the specified area, then it shows the tool tip like print etc.
Please give me solution.Would you like to have a look at these:
[1.|https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/com.sap.km.cm.docs/oss_notes_boj/sdn_oss_boj_bip/sap(bD1lbiZjPTAwMQ==)/bc/bsp/spn/scn_bosap/notes%7B6163636573733d36393736354636443646363436353344333933393338323636393736354637333631373036453646373436353733354636453735364436323635373233443330333033303331333233303336333633373339%7D.do]
[2.|https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/com.sap.km.cm.docs/oss_notes_boj/sdn_oss_boj_erq/sap(bD1lbiZjPTAwMQ==)/bc/bsp/spn/scn_bosap/notes%7B6163636573733d36393736354636443646363436353344333933393338323636393736354637333631373036453646373436353733354636453735364436323635373233443330333033303331333133383333333933313333%7D.do]
[3.|https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/com.sap.km.cm.docs/oss_notes_boj/sdn_oss_boj_dev/sap(bD1lbiZjPTAwMQ==)/bc/bsp/spn/scn_bosap/notes%7B6163636573733d36393736354636443646363436353344333933393338323636393736354637333631373036453646373436353733354636453735364436323635373233443330333033303331333233303332333533323337%7D.do]
[4.|https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/com.sap.km.cm.docs/oss_notes_boj/sdn_oss_boj_dev/sap(bD1lbiZjPTAwMQ==)/bc/bsp/spn/scn_bosap/notes%7B6163636573733d36393736354636443646363436353344333933393338323636393736354637333631373036453646373436353733354636453735364436323635373233443330333033303331333233313338333733363334%7D.do]
[5.|https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/com.sap.km.cm.docs/oss_notes_boj/sdn_oss_boj_dev/sap(bD1lbiZjPTAwMQ==)/bc/bsp/spn/scn_bosap/notes%7B6163636573733d36393736354636443646363436353344333933393338323636393736354637333631373036453646373436353733354636453735364436323635373233443330333033303331333233313336333333303335%7D.do]
[6.|https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/com.sap.km.cm.docs/oss_notes_boj/sdn_oss_boj_bip/sap(bD1lbiZjPTAwMQ==)/bc/bsp/spn/scn_bosap/notes%7B6163636573733d36393736354636443646363436353344333933393338323636393736354637333631373036453646373436353733354636453735364436323635373233443330333033303331333133393338333833393338%7D.do]
Hope this helps!
AG. -
Push button in one of the columns of Table Control
Hi,
I have a requirement, where i have to display a push button in one of the columns of table control for long text. When user clicks on the control, a pop up has to be appeared in which user should be able to enter some meaning ful description and save it. please suggest me how to do this requirement.
Best Regards,
Phani Kumar. SHai,
You can drag n drop a button to the required column in the table control and give the required parameters like ok_code , name etc.
You can now place a text field as the heading of the column.
Now when the user clicks the the button in a row, read the corresponding line in which he has clicked.For that u can use
get cursor lines wrk_line.
now u'll get the data in that row using
Read table it_tab into wa_tab index wrk_line.
now u can call the text editor (using FM's READ_TEXT ,EDIT_TEXT and CREATE_TEXT in which the user can enter the meaningful description and save it.
When u save the text entered save it with a key part of the row that was read earlier(keep it as the text name).
So now if u need to get the description which was entered earlier u can easily read the text (using READ_TEXT ).
I hope this will be helpful for u .
Thanks
Neeraj -
Sort up and sort Down push buttons in module pool with table control wizard
hi,
i have created 2 buttons for Sort up and sort Down push buttons in module pool with table control wizard
please any one can help me.
regardsHi
Following code is to enable and disable the tbl control using two buttons. Just alter the code and for each button write the sort code.
REPORT YJAN27_SCREEN .
TABLES: SFLIGHT, YFLIGHT_28.
TYPES: BEGIN OF struct1,
carrid like sflight-carrid,
connid like sflight-connid,
fldate like sflight-fldate,
END OF struct1.
CONTROLS TBL1 TYPE TABLEVIEW USING SCREEN 2700.
DATA: OK_CODE LIKE SY-UCOMM,
CARRID LIKE SFLIGHT-CARRID, "cols in tbl ctrl
CONNID LIKE SFLIGHT-CONNID,
FLDATE LIKE SFLIGHT-FLDATE,
itab TYPE TABLE OF STRUCT1 WITH HEADER LINE,
cols like line of TBL1-COLS,
FLAG TYPE I.
FLAG = 1.
CALL SCREEN 2700.
*& Module STATUS_2700 OUTPUT
* text
MODULE STATUS_2700 OUTPUT.
SET PF-STATUS 'BACK'.
* SET TITLEBAR 'xxx'.
ENDMODULE. " STATUS_2700 OUTPUT
*& Module USER_COMMAND_2700 INPUT
* text
MODULE USER_COMMAND_2700 INPUT.
OK_CODE = SY-UCOMM.
CASE OK_CODE.
WHEN 'BACK'.
LEAVE PROGRAM.
WHEN 'DIS'. "write code for sort up
loop AT TBL1-COLS INTO COLS.
COLS-SCREEN-INPUT = 0.
MODIFY TBL1-COLS FROM COLS.
ENDLOOP.
FLAG = 2.
WHEN 'ENA'. "write code for sort down
loop AT TBL1-COLS INTO COLS.
COLS-SCREEN-INPUT = 1.
MODIFY TBL1-COLS FROM COLS.
ENDLOOP.
FLAG = 1.
ENDCASE.
ENDMODULE. " USER_COMMAND_2700 INPUT
*& Module GET_DATA OUTPUT
* text
MODULE GET_DATA OUTPUT.
select carrid connid fldate from SFLIGHT into table itab.
ENDMODULE. " GET_DATA OUTPUT
*& Module POPULATE_TBL OUTPUT
* text
MODULE POPULATE_TBL OUTPUT.
MOVE-CORRESPONDING ITAB TO SFLIGHT.
ENDMODULE. " POPULATE_TBL OUTPUT
*& Module CHANGE_SCREEN OUTPUT
* text
MODULE CHANGE_SCREEN OUTPUT. " use this module if you want to hide the other button
CASE FLAG.
WHEN 1.
LOOP AT SCREEN.
IF SCREEN-NAME = 'B_ENA'.
SCREEN-INVISIBLE = 1.
MODIFY SCREEN.
ENDIF.
ENDLOOP.
LOOP AT SCREEN.
IF SCREEN-NAME = 'B_DIS'.
SCREEN-INVISIBLE = 0.
MODIFY SCREEN.
ENDIF.
ENDLOOP.
WHEN 2.
LOOP AT SCREEN.
IF SCREEN-NAME = 'B_DIS'.
SCREEN-INVISIBLE = 1.
MODIFY SCREEN.
ENDIF.
ENDLOOP.
LOOP AT SCREEN.
IF SCREEN-NAME = 'B_ENA'.
SCREEN-INVISIBLE = 0.
MODIFY SCREEN.
ENDIF.
ENDLOOP.
ENDCASE.
ENDMODULE. " CHANGE_SCREEN OUTPUT
PROCESS BEFORE OUTPUT.
MODULE STATUS_2700.
MODULE CHANGE_SCREEN. " use this if you want to display one button at a time
MODULE GET_DATA.
loop at itab WITH control TBL1.
MODULE POPULATE_TBL. " populate tbl ctrl
endloop.
PROCESS AFTER INPUT.
MODULE USER_COMMAND_2700. " do the sort operations
loop at itab.
endloop.
Hope this helps
Regards,
Jayanthi.K -
Push button column in table control
Hi,
I have to add a few push button columns into table control. This columns has to be placed between fields of DDic table. How to do this? Shall I create new DDic structure with all the needed fields from DDic table and add also fields for push button columns? Which data element shal I use in this case for push button field? Or is the better solution to add DDic table fields one by one and then using drag and drop technique to add push button column behind it?
Thanks.Hi ,
Your Last option is better first add columns into DDIC table then Drag and
Drop it on table control .
That will better definitely.................................
if useful rewards the point..............
Thanks .
Nilesh Jain
Maybe you are looking for
-
Suddenly it seems to be on death bed....
Hello everyone, In February 2005 I purchased a 12" iBook G4. For the past year I've been very happy with it, except for recent battery issues, which isn't the problem today. You see, the unit itself has worked quite well lately, with the only problem
-
BT most frustrating customer service experience in...
I thought I would register for this site - only so I could share my experience of BT broadband customer support. It will come as no surprise to many of the customers of BT that my experience is a poor one.. but by posting I hope to clear some of the
-
Hi All I am creating return PR from t-code QM02.I am updating the return pr number into custom field in QMEL table.I am able to create a return PR and i am to update in QMEL table.Once i come back to QM02 initial scree(where we enter Quality notifica
-
AVI DV file of 9GB (45 minutes) shows only 2:50 minutes in the timeline.
Hi, I have loaded an AVI DV file of 9GB (45 minutes) in Premiere Pro CS6 but it shows only 2:50 minutes in the timeline. I have loaded much longer files in my timeline and edited it without any problems. I also tried to decode the AVI file but this l
-
Getting this error while taking Cisco ISE backup. Has anyone seen this?What is the solution? Tried with tftp/sftp repositories. Thanks.