Error using Reports icon in local Siebel client

Hi, please help.
I am using Siebel client connected to my local dbf.
I would like to run a report but using the reports icon (in all views) gives me an error:
"We detected an Error which may have occurred for one or more of the following reasons:"
"Class name incorrect or does not extend SiebelBusinessService : <?>(SBL-EAI-05010)"
Is there a specific configuration that I need to set up for the Reports icon to work in my local Siebel client?
Thanks,
Felicity

From our version of 6i Reports Builder Help, I got ...
Oracle ORACLE PL/SQL V8.0.6.3.0 - Production
You may check yours.

Similar Messages

  • Stand alone exe errors using report generation vi's

    I have a stand alone application that uses some report generation vi's. I have added the _wordsub.llb as a support file. In the main program I have told the report generations vi's where to find the _wordsub.llb so it can load the dynamic vi's as needed. The problem is when I run the stand-alone executable I get an open refernce error for one of the dynamic vi's that says that vi is not executable. But when I reconfigure the executable and include that vi as a dymaically loaded vi in addition to the _wordsub.llb, the stand alone works error free. Any suggestions?

    It really depends on what version of office you are using. Some methods have different set of parameters or even different names, labview does not adjust them accordingly, even though the code might execute but it will fail during build process. You must reselect the methods manually in order to build the executable. Most time you need to build different executables for each office version.
    -Joe

  • In my Siebel Client Application, if I click on my Reports Icon which is placed next to Site map in Toolbar, I'm getting the following error.

    Hi
    In my Siebel Client Application, if I click on my Reports Icon which is placed next to Site map in Toolbar, I'm getting the following error.
    An error has occurred creating business component '<?>' used by business object '<?>'
    Please ask your systems administrator to check your application configuration.(SBL-DAT-00222)
    Thanks in advance.
    abdul tawab.

    As Alex mentioned, You are out of luck. Unlike SP 2010, you cannot install SP 2013 on Windows 7 or any other client OS.
    Your best options are:
    Since Windows 8 Pro or above supports Hyper-V, you can run SP 2013 as a VM on Windows 8 pro
    You can use VMware Player (free) on Windows 7
    Check out this video: Setting
    up team development infrastructure for SharePoint 2013 development
    Please remember to mark your question as answered &Vote helpful,if this solves/helps your problem. ****************************************************************************************** Thanks -WS MCITP(SharePoint 2010, 2013) Blog: http://wscheema.com/blog

  • Error while using implicit remoting from Win 7 Client

    Anyone who can help with below error while implicit remoting in exchange 2010, i have verified WinRM service, and currently using power-shell v2 both on client and server.
    Error Code:
    Connecting to remote server failed with the following error message : WinRM cannot process the request.
    The following error occured while using Kerberos authentication: A specified logon session does not exist. It may alre
    ady have been terminated.
    Possible causes are:
    -The user name or password specified are invalid.
    -Kerberos is used when no authentication method and no user name are specified.
    -Kerberos accepts domain user names, but not local user names.
    -The Service Principal Name (SPN) for the remote computer name and port does not exist.
    -The client and remote computers are in different domains and there is no trust between the two domains.
    After checking for the above issues, try the following:
    -Check the Event Viewer for events related to authentication.
    -Change the authentication method; add the destination computer to the WinRM TrustedHosts configuration setting or us
    e HTTPS transport.
    Note that computers in the TrustedHosts list might not be authenticated.
    -For more information about WinRM configuration, run the following command: winrm help config. For more information,
    see the about_Remote_Troubleshooting Help topic.
    + CategoryInfo : OpenError: (System.Manageme....RemoteRunspace:RemoteRunspace) [], PSRemotingTransportExc
    eption
    + FullyQualifiedErrorId : PSSessionOpenFailed
    Aditya Mediratta

    Hi Aditya,
    Please running following command to enable the CredSSP on both client and server:
    Parameter Set: Default
    Enable-WSManCredSSP [-Role] <String> [[-DelegateComputer] <String[]> ] [-Force] [ <CommonParameters>]
    I found a blog for your reference in case I have anything misunderstanding:
    How To Use The 2012 Active Directory PowerShell Cmdlets From Windows 7
    http://blogs.technet.com/b/ashleymcglone/archive/2013/06/27/how-to-use-the-2012-active-directory-cmdlets-from-windows-7.aspx
    Thanks
    Mavis
    Mavis Huang
    TechNet Community Support

  • Hidden Report Viewer Confiugration Error on aspx pages that use report viewer web control

    I try to fix the problem. The error below is embedded on aspx pages that use report viewer web control. Please note that the div element is hidden, and the reportviewer is displaying correct contents.
    Div element hidden on aspx page
    <div id="ReportViewer1_HttpHandlerMissingErrorMessage" style="border-color:Red;border-width:2px;border-style:Solid;padding:10px;display:none;font-size:.85em;">
    <h2>
    Report Viewer Configuration Error
    </h2><p>The Report Viewer Web Control HTTP Handler has not been registered in the application's web.config file. Add &lt;add verb="*" path="Reserved.ReportViewerWebControl.axd" type = "Microsoft.Reporting.WebForms.HttpHandler, Microsoft.ReportViewer.WebForms, Version=10.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" /&gt; to the system.web/httpHandlers section of the web.config file, or add &lt;add name="ReportViewerWebControlHandler" preCondition="integratedMode" verb="*" path="Reserved.ReportViewerWebControl.axd" type="Microsoft.Reporting.WebForms.HttpHandler, Microsoft.ReportViewer.WebForms, Version=10.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" /&gt; to the system.webServer/handlers section for Internet Information Services 7 or later.</p>
    </div>
    I tried adding the two elements to web.config, but to no avail.
    Add below to system.web/httpHandlers
    <add verb="*" path="Reserved.ReportViewerWebControl.axd" type = "Microsoft.Reporting.WebForms.HttpHandler, Microsoft.ReportViewer.WebForms, Version=10.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" />
    or add below to system.webServer/handlers for Internet Information Services 7 or later.
    <add name="ReportViewerWebControlHandler" preCondition="integratedMode" verb="*" path="Reserved.ReportViewerWebControl.axd" type="Microsoft.Reporting.WebForms.HttpHandler, Microsoft.ReportViewer.WebForms, Version=10.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" />
    The required assemblies below are installed under C:\Windows\assembly folder. I have installed both Microsoft ReportViewer 2010 Redistributable, and 2008 SP1.
    Microsoft.ReportViewer.WebForms, version 10
    Microsoft.ReportViewer.Common, version 10
    Below is the whole web.config:
    <?xml version="1.0" encoding="utf-8"?>
    <!--
    For more information on how to configure your ASP.NET application, please visit
    http://go.microsoft.com/fwlink/?LinkId=169433
    -->
    <configuration>
    <connectionStrings>
    <add name="ApplicationServices" connectionString="data source=.\SQLEXPRESS;Integrated Security=SSPI;AttachDBFilename=|DataDirectory|\aspnetdb.mdf;User Instance=true" providerName="System.Data.SqlClient" />
    </connectionStrings>
    <appSettings>
    <add key="car" value="myCar" />
    <!--<add key="ReportViewerServerConnection" value="WebForm.Lab.ReportConnection, WebForm" />-->
    </appSettings>
    <system.web>
    <httpHandlers>
    <add verb = "*" path = "Reserved.ReportViewerWebControl.axd" type = "Microsoft.Reporting.WebForms.HttpHandler, Microsoft.ReportViewer.WebForms, Version=10.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" />
    <!--<add path="Reserved.ReportViewerWebControl.axd" verb="*" type="Microsoft.Reporting.WebForms.HttpHandler, Microsoft.ReportViewer.WebForms, Version=10.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" validate="false" />-->
    </httpHandlers>
    <compilation debug="true" targetFramework="4.0">
    <assemblies>
    <add assembly="Microsoft.ReportViewer.WebForms, Version=10.0.0.0, Culture=neutral, PublicKeyToken=B03F5F7F11D50A3A" />
    <add assembly="Microsoft.ReportViewer.Common, Version=10.0.0.0, Culture=neutral, PublicKeyToken=B03F5F7F11D50A3A" />
    <add assembly="Microsoft.Build.Framework, Version=4.0.0.0, Culture=neutral, PublicKeyToken=B03F5F7F11D50A3A" />
    <add assembly="System.Management, Version=4.0.0.0, Culture=neutral, PublicKeyToken=B03F5F7F11D50A3A" />
    </assemblies>
    <buildProviders>
    <add extension=".rdlc" type="Microsoft.Reporting.RdlBuildProvider, Microsoft.ReportViewer.WebForms, Version=10.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" />
    </buildProviders>
    </compilation>
    <authentication mode="Forms">
    <forms loginUrl="~/Account/Login.aspx" timeout="2880" />
    </authentication>
    <membership>
    <providers>
    <clear />
    <add name="AspNetSqlMembershipProvider" type="System.Web.Security.SqlMembershipProvider" connectionStringName="ApplicationServices" enablePasswordRetrieval="false" enablePasswordReset="true" requiresQuestionAndAnswer="false" requiresUniqueEmail="false" maxInvalidPasswordAttempts="5" minRequiredPasswordLength="6" minRequiredNonalphanumericCharacters="0" passwordAttemptWindow="10" applicationName="/" />
    </providers>
    </membership>
    <profile>
    <providers>
    <clear />
    <add name="AspNetSqlProfileProvider" type="System.Web.Profile.SqlProfileProvider" connectionStringName="ApplicationServices" applicationName="/" />
    </providers>
    </profile>
    <roleManager enabled="false">
    <providers>
    <clear />
    <add name="AspNetSqlRoleProvider" type="System.Web.Security.SqlRoleProvider" connectionStringName="ApplicationServices" applicationName="/" />
    <add name="AspNetWindowsTokenRoleProvider" type="System.Web.Security.WindowsTokenRoleProvider" applicationName="/" />
    </providers>
    </roleManager>
    <pages>
    <controls>
    <add tagPrefix="ajaxToolkit" assembly="AjaxControlToolkit" namespace="AjaxControlToolkit" />
    </controls>
    </pages>
    </system.web>
    <system.webServer>
    <modules runAllManagedModulesForAllRequests="true" />
    <validation validateIntegratedModeConfiguration="false" />
    <handlers>
    <add name="ReportViewerWebControlHandler" preCondition="integratedMode" verb="*" path="Reserved.ReportViewerWebControl.axd" type="Microsoft.Reporting.WebForms.HttpHandler, Microsoft.ReportViewer.WebForms, Version=10.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" />
    </handlers>
    <httpProtocol>
    <customHeaders>
    <remove name="X-Powered-By" />
    </customHeaders>
    </httpProtocol>
    </system.webServer>
    <system.serviceModel>
    <bindings>
    <basicHttpBinding>
    <binding name="WebService1Soap" />
    </basicHttpBinding>
    </bindings>
    <client>
    <endpoint address="http://localhost:58269/WebService1.asmx" binding="basicHttpBinding"
    bindingConfiguration="WebService1Soap" contract="ServiceReference1.WebService1Soap"
    name="WebService1Soap" />
    </client>
    </system.serviceModel>
    </configuration>
    Any idea?
    Update:
    IIS is7.5, AppPool is Integrated.
    I have tried below, none of them works:
    1) Add it only to system.web\httpHanders. Changed AppPool to classic, still got hidden error.
    2) Add it only to system.webServer\handlers. Integrated mode,still got hidden error.
    3) Add both to both element. Integrated mode, still got hidden error.

    Hi Kingofwebguru,
    According to your description, when you use reportviewer control, you got the error message: The Report Viewer Web Control HTTP Handler has not been registered in the application's web.config file.
    To troubleshoot the problem, please refer to the following steps:
    Click Start, click Run, then type InetMgr.exe and click OK.
    Click plus sign next to server name to expand it.
    Click Application Pools in left pane.
    In Application Pools list, click DefaultAppPool.
    In the Actions pane, in Edit Application Pool section, click Edit Settings to check the Pipeline mode.
    Configuration settings for the HTTP handlers are specified in the system.web/httpHandlers element and the system.webServer/handlers element. of your application Web.config file. The handler specified in system.web/httpHandler is used by Internet Information
    Services (IIS) 6.0 or IIS 7.0 in Classic mode, whereas the handler specified in system.webServer/handlers is used by IIS 7.0 in Integrated mode. To use IIS 7.0 in Integrated mode, you must remove the HTTP handler in system.web/httpHandlers. Otherwise, IIS
    will not run the application, but will display an error message instead.
    For more information about Web.config Settings for ReportViewer, please refer to the following document:
    http://msdn.microsoft.com/en-us/library/ms251661.aspx
    If you have any more questions, please feel free to ask.
    Thanks,
    Wendy Fu
    If you have any feedback on our support, please click
    here.
    Wendy Fu
    TechNet Community Support

  • I use CS5 and all of a sudden I am getting a notification that says there is an error with my icons. It's telling me to contact support or reinstall. The problem is I don't know where my disks are to re-install. Any suggestions?

    I use CS5 and all of a sudden I am getting a notification that says there is an error with my icons. It's telling me to contact support or reinstall. The problem is I don't know where my disks are to re-install. Any suggestions?

    doodlebug,
    Am I just out of luck until I find those?
    You may try Adobe Support (phone),
    http://helpx.adobe.com/adobe-connect/adobe-connect-phone-numbers.html
    and talk to them about your registration, but I am unsure whether they can help you with anything pre CC (There was a Customer Care option with chat which seems to have stopped working).
    If you are still out of luck, please report back, and I will try to ask someone to find the right someone to help you.

  • I am using report generation toolkit 1.1 with Labview 7.0 and Office 2003 profession​al. The create new report VI opens Excel but throws error (-21471672​62- from automation open VI) when I try to open MS word. please help...

    I am using report generation toolkit 1.1 with Labview 7.0 and Office 2003 professional. The create new report VI opens Excel but throws error (-2147167262- from automation open VI) when I try to open MS word. please help...

    Hi Leo22,
    Does this error occur if you use any of the example programs that come shipped with LabVIEW? I would try opening one of the examples that write data to Word and see if those give you an error. Also, have you tried just putting down a New Report.VI and change the report type to Word? If this simple vi (that's all you need to open Word) breaks, I would check to see if there are any instances of Word still open. Check the task manager to see if any word processes are still open. There should not be a problem accessing Word 2003 from LabVIEW 7.0. If neither of these solutions work, please give some more detail about your application and we can research further. Thanks!
    Jeremy L.
    National Instruments
    Jeremy L.
    National Instruments

  • Error when using Report Generation Toolkit

    Hi, all,
    I am using Report generation toolkit to generate a report in either
    word or excel format. But i even can't run the "new report.vi". It
    returns an error code of "Bad variable type (-2147352568)", and seems
    this error comes out from the "call by reference" after the
    word/excel's "open VI reference". I have checked the folder
    "C:\Program Files\National Instruments\LabVIEW
    6.1\vi.lib\addons\_office", there are "_exclsub.llb" and
    "_wordsub.llb". The respect VIs are all inside. I don't know why there
    is such error. Currently i am using labview 6.1, Microsoft office 2000
    and Windows NT 4.0.
    Your kindly help will be appreciated very much!!!
    Thannk you in advance!! ^_^
    Your sincerely,
    celery

    So, if you place just New Report.vi on the Block Diagram, wire in the report type and run it, it gives you this error? Do the example programs which ship with the toolset give this same error also? If so, I would just reinstall the toolset first and see if that helps. It sounds like the entire install is corrupt.
    J.R. Allen

  • Error Showing While Using Report Generation ToolKit VIs

    Hi All,
               When I use report generation VIs Like Excel Easy Tables its showing following errors and i am not able to contiune using the same,
    C:\Program Files\National Instruments\LabVIEW 8.2\vi.lib\utility\NIReport.llb\Set Report Font.vi
        - LabVIEW 8.0 changed a constant that was wired to a Case structure to a hidden control to maintain compatibility with LabVIEW 7.1 and earlier.
        - LabVIEW 8.0 changed a constant that was wired to a Case structure to a hidden control to maintain compatibility with LabVIEW 7.1 and earlier.
    what might be the issue, i am using LabVIEW 8.2

    Hi,
    In
    LabVIEW 7.1 and earlier, subVIs could be kept in memory by wiring a
    constant to a Case structure and placing the subVI in a case that would
    not be executed. For example, you could wire a True constant to the
    Case structure and place a subVI in the False case of the Case
    structure, and LabVIEW would load the subVI along with the calling VI.
    However, from LabVIEW 8.0 onwards, the case structure is optimized to remove code that is not going to be executed. Changing the
    constant to a control ensures that this VI behaves as it did in LabVIEW
    7.1 and earlier. If the intent is not to keep the subVIs in memory, you
    can change this control back to a constant by right-clicking the
    control and selecting 'Change to Constant' from the shortcut menu. The
    proper way to keep a subVI in memory without calling it is to use a
    Static VI Reference.
    Good Luck!
    Warm regards,
    Karunya R
    National Instruments
    Applications Engineer

  • Error 1045 Using Report Generation Excel 2010

    Hello,
    The attached code throws an error 1045 when using Excel 2010.  I don't get this error when using Excel 2007.
    Please Advise
    Thanks
    Attachments:
    Source.zip ‏66 KB

    Take a look at this Knowledge Base article and see if if helps.
    Error 1045 When Using Report Generation Toolkit for Microsoft Office
    http://digital.ni.com/public.nsf/allkb/3E4102D8B91D0F9E86256CE0006BADCB
    Applications Engineer
    National Instruments

  • When I check my boot SSD drive using Disk Utility under Mavericks, I often get "Incorrect number of extended attributes" errors.  But if I boot off an external drive and check the same SSD, no errors are reported.  Is this a bug in Mavericks?

    When I check my boot SSD drive using Disk Utility under Mavericks, I often get "Incorrect number of extended attributes" errors.  But if I boot off an external drive and check the same SSD, no errors are reported. 
    This happens not just with the SSD in my Mac Mini, but with another SSD in my MacBook (both now running Mavericks).  So far as I know, all of the kit I am using is in good order (despite the file corruption reports).  So I am beginning to wonder if it could be due to a bug in Mavericks?  Both SSD drives have been formatted to MacOS Extended (journaled) format.  Should I have used a different format, I wonder?
    Has anyone else encountered this issue?
    Does anyone have a solution?
    Or an explanation that might help my investigation of the issue?
    Thanks guys,

    I understand that the Corsair Force 3 is not one of the SSD drives that are supported on Apple Macs. 
    I did try downloading and using Trim Enabler, but the error message came up both when it was off and when it was on.
    I understand that not everyone thinks Trim Enabler is a good program, though there is a new version out now, so I may give it another try.

  • Error using JXL api in a KM Report

    Hi Expert,
    My report have to use JXL api. I have already a DC containing libraries, including JXL 2.6.2.
    I declare my DC in Used DC of my report, but each time I launch it it throws me this error :
    "error executing: /reporting/reports/Content Management/Tools/rise_metrics/1237311667619.xml(com.sapportals.wcm.service.reporting.ReportInput@356422d2) - java.lang.NoClassDefFoundError: jxl/format/CellFormat at com.ctsao.project.rise.metrics.RISEMetrics.execute(RISEMetrics.java:460) at com.sapportals.wcm.repository.manager.reporting.monitor.ReportComponent$ReportWrapper.execute(ReportComponent.java:160) at com.sapportals.wcm.service.reporting.scheduler.ReportScheduler$Runner.run(ReportScheduler.java:220)"
    Is it possible to use this API in a report or there is some restriction ?
    Thanks in advance for your help,
    Jean-Edouard Nicolet.

    Hi,
    Try to include the jxl.jar file inside your private/lib folder of project and run as a workaround.
    Regards
    Baby

  • Hello, I am trying to upgrade to yosemite, but I get the "disk cannot be used to startup your computer" error. Resizing the partition does not work, I get the error "MediaKit reports no such partition" probably because I installed linux in dual boot

    Hello, I am trying to upgrade my macbook pro to yosemite, but I get the "disk cannot be used to startup your computer" error.
    Resizing the partition does not work for me and I get the error "MediaKit reports no such partition" probably because I installed linux in dual boot and the disk manager is lost.
    Anyway to tell the yosemite installer that it should not pay attention whether the disk is bootable or not ?
    If I am doomed, any way to delete the installer and downloaded OS from my hard drive ?
    Thanks for your help

    As usual, the Linux installer wrecked the partition table. You would have to boot from your OS X installation disc and repartition. Doing so will of course remove all data from the drive, so you must back up first if you haven't already done so.

  • 10.6 Email-Server/Postfix Helo command rejected - local SMTP clients won't use FQDN

    Hi,
    I set up a 10.6 server as mail-server which works (more or less) fine. I can send and receive internal and external Emails from various Macs with mail.app and Windows-Boxes with Thunderbird. However, some clients will be rejected due to wrong Helo strings
    e.g. a Windows-Box using Outlook express
    server postfix/smtpd[73194]: NOQUEUE: reject: RCPT from winbox.intranet.example.com[192.168.2.21]: 504 5.5.2 <winbox>: Helo command rejected: need fully-qualified hostname; from=<[email protected]> to=<[email protected]> proto=ESMTP helo=<winbox>
    similar happens with my router sending status-Emails (replace "winbox" with "router")
    finally my stand-alone-fax-machine uses it's ip-address as helo-string (helo=<192.168.2.10>, similar error)
    For now I've commented out
    smtpd_helo_restrictions = reject_invalid_helo_hostname
    #reject_non_fqdn_helo_hostname
    which makes things work. But that's not the right way, I guess, moreover since this entry is "fixed" by Server-Admin ever now and then.
    Does this problem arise from misconfigured boxes or a misconfigured OSX-Server? Hope the latter since there're no options to change this in my router nor my fax-machine...
    Thanks

    Try this.
         Symptoms   Users who use Microsoft Outlook as their email client and whoconnect to an email server running on Mac OS X Server v10.6 may not beable to send mail. The following (or similar) alert is returned toOutlook clients:    The message could not be sent becauseone of the recipients was rejected by the server. The rejected emailaddress was "[email protected]" is subject "example", account:"mail.example.com" , server "mail.example.com", protocol: SMTP, serverresponse: "504 5.5.2 < hostname > : Helo command rejected: needfully qualified host name", port: 25, secure (SSL): no, server error:504, error number: 0x800CCC79.      Products Affected   Mac OS X Server 10.6        Resolution    In Mac OS X Server v10.6, Postfix is configuredto require a fully qualified hostname from SMTP clients. This settingis configurable and the restriction can be removed, however anymodification of a security-related setting should be evaluated prior tomaking the change.   Once you have evaluated the change, you can use the following steps to implement it:   Note: Before proceeding, back up the /etc/postfix/main.cf file as a precaution.  
    In /etc/postfix/main.cf, locate the smtpd_helo_restrictions setting
    Remove "reject_non_fqdn_helo_hostname" from the list of settings.
    Restart the Mail service.

  • Print report on network/local printer(plz help)

    Plz Forms gurus, help me to solve this problem it's very very importante for me
    We have at a lot application witch work in client/server mode using forms/Reports 6i.With these applications we haven't problem to print report on printer using RUN_PRODUCT.Now we want to migrate on Forms/Reports 9i.When we use Run_Report_Object to print report on network print, we are encountring problems, the following errors occurs:
    REP-713: Printer name '\DT_C2_0_8102\LaserJet1100' is wrong in the parameter DESNAME.
    LaserJet1100 is a network printer install on the machine witch have DT_C2_0_8102 in the network.
    I would like to know, if there an other way for naming printer? Secondly, i would like to if i add a network printer on my machin and define it as my default printer. Am i obliged to define the parameter DESNAME in the call off RUN_REPORT_OBJECT. If someone have a sample code about how to print on printer, it'll be helpfull.
    Plz forms gurus help me to solve my problem.
    Thanks in advance.
    TYAG

    Duplicate?
    Print report on network/local printer

Maybe you are looking for

  • PDF viewer dead in 1.3.1

    My pdf viewer was working just fine before the update but now it doesn't load any of the previously fine pdfs. Help!  Post relates to: Pre p100eww (Sprint)

  • I've Had it with my powerbook

    Hi, I have a 10/2004 Powerbook 1.5 ghz $2400 model and I am on my last straw becasue last year, about a month after i got the sleep light went crazy and started blinking uncontrollably, which i had my logic board replaced, then the light wouldnt work

  • Imac is running very slow

    I've got a 24" imac with the 2.4 GHz Intel core 2 duo and 4 GBs of ram. In January I did a software update and the imac hasn't run the same since. At first I had problems booting up. I would get a file folder with a question mark in the middle. I tho

  • How get xml-data at servlet by http and parse it?

    hello! please help me who can, i have very urgent task but not much skilful to deal with work in web. is anywhere source code or similar example of task to get xml-data at servlet by http and parse it . thank you in advance

  • Upconvert from LabVIEW 4.02 to LabVIEW 2011

    Wiii, my university library finally managed to find the missing disk from the book "LabVIEW power programming". Now I just wanted to check it out but all the VI's are to old. Can someone of NI upconvert them? I uploaded the .zip (with password) conta