Exporting Module pool with screen

Hi,
I want to export module pool that I created to a file and import it back later. I could find a SAP Program RSTXSCRP to export SAPscript but no success in exporting a function module. Please help.
Regards,
Nikhil

Hi Nikhil!
If you just want to do this once, you can use transaction SE80 and menu point Utilities - More utilities - download (for each include / component).
Otherwise a special program is easier to use, take e.g. this one:
http://www.members.tripod.com/abap4/Upload_and_Download_ABAP_Source_Code.html
Regards,
Christian
P.S.: or these one:
... or this one:
http://sap.ittoolbox.com/code/d.asp?d=1623&a=s
https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/com.sap.km.cm.docs/library/webas/abap/finding your code in bsp applications.article
http://www.geocities.com/rmtiwari/Resources/Utilities/WebViewer.html
Message was edited by: Christian Wohlfahrt

Similar Messages

  • SELECT-OPTIONS in Module Pool Sub-Screen

    Hi,
    I have been working on a Module-Pool Development, in the header portion of the Screen, I have provided a Selection-Screen as a Sub-Screen because the requirement specifies to display a SELECT-OPTION in the Header Area.
    Now the problem is that, when working with the Screen, as soon as I press <ENTER> the Main Screen re-calls the Selection-Screen in the Sub-Screen area and all the entries made in the Selection-Screen are reset/erased.
    Kindly provide a solution either to stop the <ENTER> action to re-call the sub-screen. Or on any alternate method(s) to  provide a SELECT-OPTION on a Module Pool based Screen UI.
    MAIN SCREEN Code:
    *  PROCESS BEFORE OUTPUT
    PROCESS BEFORE OUTPUT.
    *~  Set PF-STATUS and TiTLE for Screen 100
      MODULE status_0100.
    *~  Call the Subscreen Dynamically
      CALL SUBSCREEN subscr1 INCLUDING sy-cprog gv_dynnr1.
      CALL SUBSCREEN subscr2 INCLUDING sy-cprog gv_dynnr2.
    *  PROCESS AFTER INPUT
    PROCESS AFTER INPUT.
    *~  Handle the Exit Commands of Screen 100
      MODULE user_command_0100 AT EXIT-COMMAND.
    *~  Handle the User Command(s) for screen 100
      MODULE user_action_0100.
      CALL SUBSCREEN subscr1.
      CALL SUBSCREEN subscr2.
    So whenever <ENTER> is pressed, the PBO re-calls:
    CALL SUBSCREEN subscr1 INCLUDING sy-cprog gv_dynnr1.
    and the Selection-Screen is reset.
    Regards,
    Nishant Nayyar.

    Haii Nishant,
    This problem was earlier solved by one of the members and after going through it i have now created a select-option in the Subscreen. Just create two input fields, name them as if they were low and high (for convinience as in case of select-option).
    U now need to create a table of type rstabfield.
    Ex: gt_rstab_bukrs type rstabfield.
    Now create a button and assign a Fcode for it. When you click on this button then u need to implement the ranges functionality as in select-option. For that use the following function module:
    CALL FUNCTION 'COMPLEX_SELECTIONS_DIALOG'
    EXPORTING
      TITLE                   = ' '
       TEXT                    = ''
       SIGNED                  = 'X'
       SEARCH_HELP             = 'H_T001'
       TAB_AND_FIELD           = gt_rstab_bukrs
      TABLES
        RANGE                   = rg_bukrs1.
    Hope it helps.
    Best Regards,
    rama

  • Calling a module pool program screen to an executable program

    Hi gurus,
    I have created a executable program to use selection-screen and want to see my output in module pool program where I have designed table control according to my requirement.
    How can I call the module-pool program screen from an executable program?
    Any help?
    Regards
    Mac

    Hi Mac,
    I think you can proceed with a report program alone . There you create a screen with the table control to populate your result.
    In the report program, after getting values for internal table for your display, just call the said screen.
    i.e.
    CALL SCREEN <screen number>.
    Hope this may help you.
    Regards,
    Smart Varghese

  • Sort up and sort Down push buttons in module pool with table control wizard

    hi,
    i have created 2 buttons for Sort up and sort Down push buttons in module pool with table control wizard
    please any one can help me.
    regards

    Hi
    Following code is to enable and disable the tbl control using two buttons. Just alter the code and for each button write the sort code.
    REPORT  YJAN27_SCREEN                                               .
    TABLES: SFLIGHT, YFLIGHT_28.
    TYPES: BEGIN OF struct1,
          carrid like sflight-carrid,
          connid like sflight-connid,
          fldate like sflight-fldate,
           END OF struct1.
    CONTROLS TBL1 TYPE TABLEVIEW USING SCREEN 2700.
    DATA: OK_CODE LIKE SY-UCOMM,
          CARRID LIKE SFLIGHT-CARRID,                                    "cols in tbl ctrl
          CONNID LIKE SFLIGHT-CONNID,
          FLDATE LIKE SFLIGHT-FLDATE,
          itab TYPE TABLE OF STRUCT1 WITH HEADER LINE,
          cols like line of TBL1-COLS,
          FLAG TYPE I.
    FLAG = 1.
    CALL SCREEN 2700.
    *&      Module  STATUS_2700  OUTPUT
    *       text
    MODULE STATUS_2700 OUTPUT.
      SET PF-STATUS 'BACK'.
    *  SET TITLEBAR 'xxx'.
    ENDMODULE.                 " STATUS_2700  OUTPUT
    *&      Module  USER_COMMAND_2700  INPUT
    *       text
    MODULE USER_COMMAND_2700 INPUT.
    OK_CODE = SY-UCOMM.
    CASE OK_CODE.
      WHEN 'BACK'.
        LEAVE PROGRAM.
      WHEN 'DIS'.                                                         "write code for sort up
        loop AT TBL1-COLS INTO COLS.
           COLS-SCREEN-INPUT = 0.
            MODIFY TBL1-COLS FROM COLS.
        ENDLOOP.
        FLAG = 2.
      WHEN 'ENA'.                                                       "write code for sort down
        loop AT TBL1-COLS INTO COLS.
            COLS-SCREEN-INPUT = 1.
            MODIFY TBL1-COLS FROM COLS.
        ENDLOOP.
        FLAG = 1.
    ENDCASE.
    ENDMODULE.                 " USER_COMMAND_2700  INPUT
    *&      Module  GET_DATA  OUTPUT
    *       text
    MODULE GET_DATA OUTPUT.
      select carrid connid fldate from SFLIGHT into table itab.
    ENDMODULE.                 " GET_DATA  OUTPUT
    *&      Module  POPULATE_TBL  OUTPUT
    *       text
    MODULE POPULATE_TBL OUTPUT.
        MOVE-CORRESPONDING ITAB TO SFLIGHT.
    ENDMODULE.                 " POPULATE_TBL  OUTPUT
    *&      Module  CHANGE_SCREEN  OUTPUT
    *       text
    MODULE CHANGE_SCREEN OUTPUT.    " use this module if you want to hide the other button
    CASE FLAG.
      WHEN 1.
        LOOP AT SCREEN.
          IF SCREEN-NAME = 'B_ENA'.
            SCREEN-INVISIBLE = 1.
             MODIFY SCREEN.
          ENDIF.
        ENDLOOP.
        LOOP AT SCREEN.
          IF SCREEN-NAME = 'B_DIS'.
            SCREEN-INVISIBLE = 0.
             MODIFY SCREEN.
          ENDIF.
       ENDLOOP.
      WHEN 2.
        LOOP AT SCREEN.
          IF SCREEN-NAME = 'B_DIS'.
            SCREEN-INVISIBLE = 1.
            MODIFY SCREEN.
          ENDIF.
        ENDLOOP.
        LOOP AT SCREEN.
          IF SCREEN-NAME = 'B_ENA'.
            SCREEN-INVISIBLE = 0.
             MODIFY SCREEN.
          ENDIF.
       ENDLOOP.
    ENDCASE.
    ENDMODULE.                 " CHANGE_SCREEN  OUTPUT
    PROCESS BEFORE OUTPUT.
    MODULE STATUS_2700.
    MODULE CHANGE_SCREEN.     " use this if you want to display one button at a time
    MODULE GET_DATA.
    loop at itab WITH control TBL1.
        MODULE POPULATE_TBL.       " populate tbl ctrl
    endloop.
    PROCESS AFTER INPUT.
    MODULE USER_COMMAND_2700.    " do the sort operations
    loop at itab.
      endloop.
    Hope this helps
    Regards,
    Jayanthi.K

  • Module Pool Selection Screen

    The user wants the custom module pool selection screen to look like a list selection screen.  Meaning that they want to have the multiple selection box come up at the end of the field.  I don't think that this is possible but maybe someone has some ideas

    Use code like the following in your TOP include.
    Note that we have defined screen 500 in the code.
    Now in your transaction code for this module pool set this as the openingscreen. Please revert in case of any clarifications.
    Code.
    =AF---
    selection-screen : begin of screen 500 as window.
    selection-screen : begin of block abc with frame title text-001.
    select-options : s_bukrs for mseg-bukrs no intervals no-extension
    obligatory.
    parameter : p_postdt like mkpf-budat obligatory.
    select-options : s_vendor for mseg-lifnr.
    selection-screen : end of block abc.
    selection-screen : begin of block def with frame title text-002.
    parameter : c_fore radiobutton group g1 default 'X',
    c_back radiobutton group g1 .
    selection-screen : end of block def.
    selection-screen : end of screen 500.
    at selection-screen.
    if sy-ucomm = 'CRET'.
    perform get_data.
    endif.

  • Module pool  with object oriented programming

    can anyone send me links for module pool with object oriented programming.

    hi,
    some helful links.
    Go through the below links,
    For Materials:
    1) http://help.sap.com/printdocu/core/Print46c/en/data/pdf/BCABA/BCABA.pdf -- Page no: 1291
    2) http://esnips.com/doc/5c65b0dd-eddf-4512-8e32-ecd26735f0f2/prefinalppt.ppt
    3) http://esnips.com/doc/2c76dc57-e74a-4539-a20e-29383317e804/OO-abap.pdf
    4) http://esnips.com/doc/0ef39d4b-586a-4637-abbb-e4f69d2d9307/SAP-CONTROLS-WORKSHOP.pdf
    5) http://esnips.com/doc/92be4457-1b6e-4061-92e5-8e4b3a6e3239/Object-Oriented-ABAP.ppt
    6) http://esnips.com/doc/448e8302-68b1-4046-9fef-8fa8808caee0/abap-objects-by-helen.pdf
    7) http://esnips.com/doc/39fdc647-1aed-4b40-a476-4d3042b6ec28/class_builder.ppt
    8) http://www.amazon.com/gp/explorer/0201750805/2/ref=pd_lpo_ase/102-9378020-8749710?ie=UTF8
    1) http://www.erpgenie.com/sap/abap/OO/index.htm
    2) http://help.sap.com/saphelp_nw04/helpdata/en/ce/b518b6513611d194a50000e8353423/frameset.htm
    <u>Sample std pgms.</u>
    ABAP_OBJECTS_ENJOY_0           Template for Solutions of ABAP Object Enjoy Course
    ABAP_OBJECTS_ENJOY_1           Model Solution 1: ABAP Objects Enjoy Course      
    ABAP_OBJECTS_ENJOY_2           Model Solution 2: ABAP Objects Enjoy Course      
    ABAP_OBJECTS_ENJOY_3           Model Solution 3: ABAP Objects Enjoy Course      
    ABAP_OBJECTS_ENJOY_4           Model Solution 4: ABAP Objects Enjoy Course      
    ABAP_OBJECTS_ENJOY_5           Model Solution 5: ABAP Objects Enjoy Course      
    DEMO_ABAP_OBJECTS              Complete Demonstration for ABAP Objects          
    DEMO_ABAP_OBJECTS_CONTROLS     GUI Controls on Screen                           
    DEMO_ABAP_OBJECTS_EVENTS       Demonstration of Events in ABAP Objects          
    DEMO_ABAP_OBJECTS_GENERAL      ABAP Objects Demonstration                       
    DEMO_ABAP_OBJECTS_INTERFACES   Demonstration of Interfaces in ABAP Objects      
    DEMO_ABAP_OBJECTS_METHODS      Demonstration of Methods in ABAP Objects         
    DEMO_ABAP_OBJECTS_SPLIT_SCREEN Splitter Control on Screen
    Rgds
    Reshma

  • Module Pool with Selection Screen

    I have a module pool in which I've created a sub screen to accommodate select-options.
    SELECTION-SCREEN BEGIN OF SCREEN 1010 AS SUBSCREEN.
    select-options: r_matnr for mara-matnr.
    selection-screen end of screen 1010.
    I've put this selection screen in an include of the module pool.
    Now I can't seem to see my variable, r_matnr, in the program. How to I pass the value to the program and what have I done wrong. Perhaps where I placed the selection-screen.
    Any help would be appreciated.
    PS... I can see my screen but when I put the debug on, no value is in r_matnr.
    Thanks Marianne

    Hi Mariane,
    Placing the selection screen declarations in an include does not make any issues. Can you please check your code. For your reference, I am placing a simple piece of code, in which I am also calling a selection screen from within a module pool and displaying the output of the select options. Execute this code and check what is the difference between your code and this.
    REPORT zabi_test04.
    INCLUDE zabi_test04_i001.
    INCLUDE zabi_test04_i002.
    START-OF-SELECTION.
       CALL SCREEN 9000.
    *&      Module  STATUS_9000  OUTPUT
    *       text
    MODULE status_9000 OUTPUT.
       SET PF-STATUS 'STAT9000'.
       SET TITLEBAR 'TL1'.
    ENDMODULE.                 " STATUS_9000  OUTPUT
    *&      Module  USER_COMMAND_9000  INPUT
    *       text
    MODULE user_command_9000 INPUT.
       save_ok = ok_code.
       CLEAR ok_code.
       CASE save_ok.
         WHEN 'BACK' OR 'EXIT' OR 'CANCEL'.
           LEAVE PROGRAM.
         WHEN '&SELECT'.
           lv_dynnr  = '1001'.
           CALL SCREEN 9001.
       ENDCASE.
    ENDMODULE.                 " USER_COMMAND_9000  INPUT
    *&      Module  STATUS_9001  OUTPUT
    *       text
    MODULE status_9001 OUTPUT.
       SET PF-STATUS 'STAT9001'.
       SET TITLEBAR 'TL2'.
    ENDMODULE.                 " STATUS_9001  OUTPUT
    *&      Module  USER_COMMAND_9001  INPUT
    *       text
    MODULE user_command_9001 INPUT.
       save_ok = ok_code.
       CLEAR ok_code.
       CASE save_ok.
         WHEN 'BACK' OR 'EXIT' OR 'CANCEL'.
           LEAVE TO SCREEN 0.
         WHEN '&EXECUTE'.
           WRITE s_matnr-low.
           LEAVE TO  LIST-PROCESSING.
       ENDCASE.
    ENDMODULE.                 " USER_COMMAND_9001  INPUT
    *&  Include           ZABI_TEST04_I001
    TABLES : mara.
    DATA : ok_code    TYPE sy-ucomm,
            save_ok    TYPE sy-ucomm,
            lv_dynnr   TYPE sy-dynnr VALUE '1001'.
    *&  Include           ZABI_TEST04_I002
    SELECTION-SCREEN BEGIN OF SCREEN 1001 AS SUBSCREEN.
    *PARAMETERS p_werks  TYPE t001w-werks.
    SELECT-OPTIONS s_matnr FOR mara-matnr.
    SELECTION-SCREEN END OF SCREEN 1001.
    Regards,
    Abijith

  • Module Pool - Refresh Screen Fields Progmatically

    Hello All!
    I have a slightly frustrating problem. I have built a Module Pool application to display shipments and their underlying deliveries (various information from each).
    I have structured the application as follows
    An object to store the Data. This object has an internal table of Shipments and an internal table of Deliveries. The tables are related by TKNUM. When the application needs to display a shipment, it requests the shipment's information and the underlying deliveries information from the object. The object is structured to move through the shipments with methods like "GetFirstHeader", "GetPrevHeader", "GetNextHeader", "GetLastHeader". These return the data for the application to use.
    The Deliveries are displayed in a CL_SALV_TABLE, the Shipment information is displayed in textbox type fields above the table.
    The form for display has buttons to trigger the "Move" methods of the data object. This currently will retrieve the new data from the object, modify the fields and the alv grid and then go back through PBO (I'm assuming because a button was pressed). This works well. It will bring in the new data and refresh the screen everything is fine.
    I also have a button to print the currently displayed Shipment and Deliveries. This Print is handled through a SmartForm.
    The area that is giving me troubles is my other button. Since the Application can store a range of shipments at once, I have a "Print All" button. This button moves to the first shipment in the data object,
    calls the Print Form, then moves through the rest of the data object calling the Print Form for each Shipment Displayed. This happens from one button push. The problem I am running into is that the screen does not refresh when the data changes during this movement through the data objects. I believe this is due to the PBO module not being triggered yet. My question is, is there a way to refresh the screen progmatically?
    I have tried SET USER-COMMAND to move through the data, instead of calling the "GetFirstHeader" and "GetNextHeader" method directly, but that has some unpredictable behavior (works in debug, not in regular execution). I have also tried a LEAVE SCREEN statement, as that would trigger the PBO, since the Next Screen is set to the same screen number, but that kills execution of that block of code at the LEAVE SCREEN STATEMENT.
    I am including my code from my PAI module that runs this processing, hopefully that will help.
    << unformatable code removed >>
    Moderator message - Please go through your code and post only what is relevant to your question.
    Edited by: Rob Burbank on Apr 28, 2009 1:44 PM

    MODULE USER_COMMAND_9999 INPUT .
      CASE OK_CODE .
        WHEN 'NEXT' .
          PERFORM Next .
          PERFORM GetGridData .
          PERFORM RefreshALV .
        WHEN 'PREV' .
          PERFORM Prev .
          PERFORM GetGridData .
          PERFORM RefreshALV .
        WHEN 'EXIT' .
          SET SCREEN 0 .
        WHEN 'PRNT' .
          PERFORM Print .
        WHEN 'PRNA' .
          PERFORM PrintAll .
        WHEN 'BACK' .
          PERFORM HideInitials .
          SET SCREEN '1000' .
        WHEN 'CANC' .
          SET SCREEN '1000' .
        WHEN 'FRST' .
          PERFORM First .
          PERFORM GetGridData .
          PERFORM RefreshALV .
        WHEN 'LAST' .
          PERFORM Last .
          PERFORM GetGridData .
          PERFORM RefreshALV .
        WHEN 'CFAX' .
          PERFORM Show6000 .
      ENDCASE .
    ENDMODULE .
    FORM PrintAll .
      DATA sPromptB TYPE STRING .
      DATA sPromptM TYPE STRING .
      DATA sPromptE TYPE STRING .
      DATA sPromptF TYPE STRING .
      DATA cAnswer  TYPE C LENGTH 1 .
      IF NOT oLTend->isEmpty( ) = 1 .
        sPromptB = text-995 .
        sPromptM = ITOTSHIPNUM .
        sPromptE = text-994 .
        CONCATENATE sPromptB sPromptM sPromptE INTO sPromptF SEPARATED BY SPACE .
        CALL FUNCTION 'POPUP_TO_CONFIRM'
          EXPORTING
            TITLEBAR                    = 'Print All?'
            TEXT_QUESTION               = sPromptF
            DISPLAY_CANCEL_BUTTON       = ' '
          IMPORTING
            ANSWER                      = cAnswer
          EXCEPTIONS
            TEXT_NOT_FOUND              = 1
            OTHERS                      = 2 .
        IF SY-SUBRC <> 0 .
          MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4 .
        ENDIF .
        IF cAnswer = '1' .
          PERFORM First .
          PERFORM GetGridData .
          PERFORM RefreshALV .
          " >>> Need Screen Refreshed right here
          PERFORM Print .
          DO .
            PERFORM Next .
            PERFORM GetGridData .
            PERFORM RefreshALV .
            " >>> Need Screen Refreshed right here
            PERFORM Print .
            IF oLTend->GetIndex( ) = oLTend->GetCount( ) .
              EXIT .
            ENDIF .
          ENDDO .
        ENDIF .
      ENDIF .
    ENDFORM .
    That is the general flow. Hope that helps, if more info is needed, let me know.

  • Select-option in module pool  with table Control

    HI,
    How to use the select-option in Module Pool and how Can i use the Table control in it.
    Can any body give me some Clues.
    with rgds
    Ranjith

    Hi ..
    PBO.
    LOOP at <table contriol>
    module --- Inside the module
    DATA: g_uti TYPE REF TO cl_fobu_input_util.
      if rollname <> space.
         CREATE OBJECT g_uti
           EXPORTING typename =rollname.
    *....convert to external pattern
         CALL METHOD g_util->output_convert
           EXPORTING
             field_value_int = p_value                 " This is Tablecontrol-low
           IMPORTING
             field_value_ext = p_value.              " Retrun value for Low
    ENDLOOP.
    lly you have code in PAI
    DATA: g_util_1 TYPE REF TO cl_fobu_input_util.
      if rollname <> space.
         CREATE OBJECT g_util_1
           EXPORTING typename = rollname.
    *....convert to internal pattern
         CALL METHOD g_util_1->input_convert
           EXPORTING
             field_value_ext   = p_value
           IMPORTING
             field_value_int_c = p_value.
    The above code should be written for tablecontrol-high aswell..
    you can also refer: Inlcude LSE16NF10 line no 341 & 434 (SE16n)
    Nag

  • Probelm in module pool selection screen

    Hi,
    I wanted to create transaction variant for my selection screen which i have to design through module pool
    if use the following code im not able to get the screen fields during trancation varian creation
    call screen 1001.
    SELECTION-SCREEN BEGIN OF SCREEN 101.
      SELECTION-SCREEN BEGIN OF BLOCK BL1.
       select-options:s_matnr for mara-matnr.
      SELECTION-SCREEN END  OF  BLOCK BL1.
    Kindly giv me a solution for the above query.
    Thanks In Advance,
    Santhiya B

    Hi,
    The easy way out is use a report program so you can have a normal selection screen and enjoy the variant capability for free. You can then do a 'call screen' so the rest of your processing will behave like a dialog program.
    If that's not possible, here's another option. It's not elegant, but I've done it. If others have better ways, please do share.
    1) Create a dummy program (ZXXXVARI). In this program, all it needs is the selection fields similar to what you have in your module pool.
    2) Add buttons to your dialog screen so users can choose variants, save variant, etc.
    3) Define internal array VALUTAB LIKE RSPARAMS.
    4) When user wants to save their selection, populate VALUTAB, then call FUNCTION 'RS_CREATE_VARIANT' EXPORTING CURR_REPORT = "ZXXXVARI", etc., or call function 'RS_CHANGE_CREATED_VARIANT', depending on whether the variant already exists on the table VARI or not.
    5) When user wants to choose a variant to use, just display the variants in VARI under his id. Once he selects a variant, CALL FUNCTION 'RS_VARIANT_CONTENTS' to retrieve the values saved and put them on the dialog screen.

  • Selection screen as subscreen in module pool main screen

    hello
    i having problem with a module pool  and a selection screen subscreen , i have my main screen 100 in my module pool
    i create a sub screen area , then in my top include i define a seleccion screen as subscreen  150
    i define some paramets and select-options ( for the select-options feature is because i choose use the subscreen )
    so far here is OK , the problem is when i fill the subscreen data and press a pushbutton define in the main screen ( 100 )
    the field are getting cleared ( BTW i call the subscreen in the PBO of the main screen ( 100 ) using call SUBSCREEN SUB_AREA INCLUDING SY-REPID '150'. ) so my question is how i can do for save the data filled in the subscreen ?
    thanks

    i find the solution of my own question:
    in the first line of the PAI event of the main screen ( where you call the subscreen ) need add 'call subscreen SUB_AREA_NAME_HERE.

  • Interval in the module pool selection screen

    Hi Experts,
       I am creating selection screen in module pool program. I know how to set search help for each field.
    But if I have select-options like fields, how can I have "Interval button". Is there any fuction module for that? should I use ranges?
    Thanks and regards,
    Venkat

    Hi,
    Follow these steps:-
    To implement select-options in module pool, first design two input/output fields (textboxes) for the low and high value of the field and name it as <field_name>-low and <field_name>-high.
    Create a button next the high value textbox and keep its sutaible function code.
    Now, to call the pop-up on this button click, we have to call the same pop-up as in standard      select-options. For this we have to use the function module COMPLEX_SELECTIONS_DIALOG.
    For this FM we have to pass the table name, field name and the range for the field whose range needs to fill when using the popup screen.
    To pass the table name and field name details into the FM, we have to declare as:
    DATA : tab TYPE rstabfield.
    This structure comprises of table name and field name.
    Pass these details in program as:-
    u2003
    *-- clear table and field details
      CLEAR tab.
    *-- append for range depending on the button clicked
    *   either for sales order or line item
      CASE sy-ucomm.
        WHEN 'VBELN'.
          tab-tablename = 'VBAP'.
          tab-fieldname = 'VBELN'.
    *--To call the popup screen for the field use code:-
      CALL FUNCTION 'COMPLEX_SELECTIONS_DIALOG'
        EXPORTING
          title             = text-002  u201Ctitle text
          text              = ' '
          signed            = 'X'
          search_help       = v_shelp u201Csearch help if required
          tab_and_field     = tab u201Ctable and field name details
        TABLES
          range             = r_vbeln u201Crange for the associated field
        EXCEPTIONS
          no_range_tab      = 1
          cancelled         = 2
          internal_error    = 3
          invalid_fieldname = 4
          OTHERS            = 5.
    Hope this helps you.
    Regards,
    Tarun

  • Module Pool with select options

    Hi,
    I have created select-option and radio button in Module pool. My req is that I when the user enters any value and click on the radio button the respective programs should be executed.
    Thanks
    Hari

    Hi Hariharan,
    I would recommend you to use primarily use push button and then after SUBMIT statement, and also the example for the same is provided below:
    *Code used to execute a report
    SUBMIT Zreport.
    *Code used to populate 'select-options' & execute report
    DATA: seltab type table of rsparams,
          seltab_wa like line of seltab.
      seltab_wa-selname = 'PNPPERNR'.
      seltab_wa-sign    = 'I'.
      seltab_wa-option  = 'EQ'.
    * load each personnel number accessed from the structure into
    * parameters to be used in the report
      loop at pnppernr.
        seltab_wa-low = pnppernr-low.
        append seltab_wa to seltab.
      endloop.
      SUBMIT zreport with selection-table seltab
                                    via selection-screen.
    *Code used to populate 'parameters' & execute report
    SUBMIT zreport with p_param1 = 'value'
                    with p_param2 = 'value'.
    Please validate the same at your end as well, please come back, if inputs are required.
    BR/Thanks
    Pranav Agrawal

  • Checkbox positioning issue in module pool program screen

    Hello All,
    I am facing one issue with the checkbox positioning in module pool program.I have designed the screen in 'SAP Signature Theme' and the checkbox position looks fine (while tested the screen in SE80) as shown below.
    Test Result from 'SAP Signature Theme':
    But the lead has a different theme in his SAP system and he got the below result where the checkbox automatically shifts right with the same code and screen design as shown below.
    Test Result from'Enjoy'  theme :
    Could you please help me resolve this strange issue as soon as possible.
    Thanks in advance!!!
    Thanks & Regards,
    Hafizul

    Hi Bhaskar,
    Sure , in fact this is has been created by dragging and dropping of the the standard checkbox template availabe in the layout,no custom code has been written for this.
    Please find the layout properties for this checkbox below.
    P9021-COMPLI_CONF is one character field.
    Please let me know if you need any other details on the same.
    Thanks & Regards,
    Hafizul

  • Import and export module pool

    Hi all,
    I need to import the module pool or dialogprogram and then export it to another .
    say from sand box to dev .
    I cannot do it through transports .
    I need to transfer everything including the screens.
    Any help would be greatly appreciated.
    Thanks
    Venki

    Hi,
    Goto SE51 -> Give the program name and screen no..
    Press display..
    For downloading In the menu ...
    UTILITIES -> MORE UTILITIES -> UPLOAD / DOWNLOAD -> DOWNLOAD..
    For uploading In the menu ...
    UTILITIES -> MORE UTILITIES -> UPLOAD / DOWNLOAD -> UPLOAD..
    Thanks,
    Naren

Maybe you are looking for