FC ports on nexus 5548?

Hi, I would like to know how many maximum FC ports can one have on a Nexus 5548 (N5K-C5548UP) without any expansion module? I have the FC_FEATURES_PKG license installed.

Cisco Nexus 5548UP Switch
The Cisco Nexus 5548UP (Figure 2) is a 1RU 10 Gigabit Ethernet, Fibre Channel, and FCoE switch offering up to 960 Gbps of throughput and up to 48 ports. The switch has 32 unified ports and one expansion slot.

Similar Messages

  • UCS FI 6248 to Nexus 5548 San port-channel - not working

    Hi all,
    I'm sure I am missing something fairly obvious and stupid but I need several sets of eyes and help.
    Here is the scenario:
    I want to be able to create san port-channels between the FI and Nexus.  I don't need to trunk yet as I can't even get the channel to come up.
    UCS FI 6248:
    Interfaces fc1/31-32
    Nexus 5548
    interfaces fc2/15-16
    FI is in end-host mode and Nexus is running NPIV mode with fport-channel-trunk feature enabled.
    I'm going to output the relevants configurations below.
    Nexus 5548:
    NX5KA(config)# show feature | include enabled
    fcoe                  1         enabled
    fex                   1         enabled
    fport-channel-trunk   1         enabled
    hsrp_engine           1         enabled
    interface-vlan        1         enabled
    lacp                  1         enabled
    lldp                  1         enabled
    npiv                  1         enabled
    sshServer             1         enabled
    vpc                   1         enabled
    interface san-port-channel 133
      channel mode active
      no switchport trunk allowed  vsan all
      switchport trunk mode off
    interface fc2/15
      switchport trunk mode off
      channel-group 133 force
    no shutdown
    interface fc2/16
      switchport trunk mode off
      channel-group 133 force
    no shutdown
    NX5KA# show vsan membership
    vsan 1 interfaces:
        fc2/13            fc2/14          
    vsan 133 interfaces:
        fc2/15            fc2/16            san-port-channel 133
    vsan 4079(evfp_isolated_vsan) interfaces:
    vsan 4094(isolated_vsan) interfaces:
    NX5KA# show san-port-channel summary
    U-Up D-Down B-Hot-standby S-Suspended I-Individual link
    summary header
    Group  Port-      Type    Protocol               Member Ports
           Channel
    133    San-po133  FC      PCP      (D)  FC       fc2/15(D)    fc2/16(D)   
    UCS Fabric Interconnect outputs:
    UCS-FI-A-A(nxos)# show san-port-channel summary
    U-Up D-Down B-Hot-standby S-Suspended I-Individual link
    summary header
    Group  Port-      Type    Protocol               Member Ports
           Channel
    133    San-po133  FC      PCP      (D)  FC       fc1/31(D)    fc1/32(D)   
    UCS-FI-A-A(nxos)#
    UCS-FI-A-A(nxos)# show run int fc1/31-32
    !Command: show running-config interface fc1/31-32
    !Time: Fri Dec 20 22:58:51 2013
    version 5.2(3)N2(2.21b)
    interface fc1/31
      switchport mode NP
      channel-group 133 force
      no shutdown
    interface fc1/32
      switchport mode NP
      channel-group 133 force
      no shutdown
    UCS-FI-A-A(nxos)#
    UCS-FI-A-A(nxos)# show run int san-port-channel 133
    !Command: show running-config interface san-port-channel 133
    !Time: Fri Dec 20 22:59:09 2013
    version 5.2(3)N2(2.21b)
    interface san-port-channel 133
      channel mode active
      switchport mode NP

    !Command: show running-config interface san-port-channel 133
    !Time: Sat May 16 04:59:07 2009
    version 5.1(3)N1(1)
    interface san-port-channel 133
      channel mode active
      switchport mode F
      switchport trunk mode off
    Changed it as you suggested...
    Followed the order of operations for "no shut"
    Nexus FC -> Nexus SAN-PC -> FI FC -> FI SAN-PC.
    Didn't work:
    NX5KA(config-if)# show san-port-channel summary
    U-Up D-Down B-Hot-standby S-Suspended I-Individual link
    summary header
    Group  Port-      Type    Protocol               Member Ports
           Channel
    133    San-po133  FC      PCP      (D)  FC       fc2/15(D)    fc2/16(D)
    NX5KA(config-if)#
    Here is the output as you requested:
    NX5KA(config-if)# show int san-port-channel 133
    san-port-channel 133 is down (No operational members)
        Hardware is Fibre Channel
        Port WWN is 24:85:00:2a:6a:5a:81:00
        Admin port mode is F, trunk mode is off
        snmp link state traps are enabled
        Port vsan is 133
        1 minute input rate 1256 bits/sec, 157 bytes/sec, 0 frames/sec
        1 minute output rate 248 bits/sec, 31 bytes/sec, 0 frames/sec
          3966 frames input, 615568 bytes
            0 discards, 0 errors
            0 CRC,  0 unknown class
            0 too long, 0 too short
          2956 frames output, 143624 bytes
            0 discards, 0 errors
          46 input OLS, 41 LRR, 73 NOS, 0 loop inits
          257 output OLS, 189 LRR, 219 NOS, 0 loop inits
        last clearing of "show interface" counters never
        Member[1] : fc2/15
        Member[2] : fc2/16
    NX5KA(config-if)#
    NX5KA(config-if)# show int brief
    Interface  Vsan   Admin  Admin   Status          SFP    Oper  Oper   Port
                      Mode   Trunk                          Mode  Speed  Channel
                             Mode                                 (Gbps)
    fc2/13     1      auto   on      sfpAbsent        --     --           --
    fc2/14     1      auto   on      sfpAbsent        --     --           --
    fc2/15     133    F      off     init             swl    --           133
    fc2/16     133    F      off     init             swl    --           133

  • FCoE with Cisco Nexus 5548 switches and VMware ESXi 4.1

    Can someone share with me what needs to be setup on the Cisco Nexus side to work with VMware in the following scenario?
    Two servers with two cards dual port FCoE cards with two ports connected to two Nexus 5548 switches that are clusterd together.  We want to team the ports together on the VMware side using IP Hash so what should be done on the cisco side for this to work? 
    Thanks...

    Andres,
    The Cisco Road Map for the 5010 and 5020 doesn't include extending the current total (12) FEX capabities.  The 5548 and 5596 will support more (16) per 55xxk, and with the 7K will support upto 32 FEX's.
    Documentation has been spotty on this subject, because the term 5k indicates that all 5000 series switches will support extended FEX's which is not the case only the 55xx will support more than 12 FEX.  Maybe in the future the terminology for the 5k series should be term 5000 series and 5500 series Nexus, there are several differences and advancements between the two series.

  • Telephony Issues on Nexus 5548

    Dear Viewers,
    I have Nexus 5548 devices in one of my client data centers and i have one 3750 switch to which all of these Avaya voice servers connect.
    The 3750 switch was initially connected through a L2 Link to a 6509 catalyst switch and the telephony applications were working correctly.
    The problem arises when i move this 3750 layer 2 link to a Nexus 5548 (OS version 5.1(3)N1 switch. All telephony calls coming from the outside (External calls) are not working as required but the internal calls work as usual.
    What is odd is that when i migrate this L2 link back to the 6509 switch, all works as usual. This is just a layer 2 connection and i am wondering why this is not possible.
    The vlan is accepted on all relevant trunks. I also deactivated igmp snooping on this voice vlan on the Nexus 5548 thinking it would help but in vain.
    Any ideas and suggestions are welcome.
    regards.
    Alain

    This is my radius config......  on a 5K
    radius-server timeout 7
    radius-server host 10.28.42.20 key 7 "Password" auth-port 1645 acct-port 1646 authentication accounting
    radius-server host 10.28.42.21 key 7 "Password" auth-port 1645 acct-port 1646 authentication accounting
    aaa group server radius Radius-Servers
     server 10.28.42.20
     server 10.28.42.21
    aaa authentication login default group Radius-Servers
    ip radius source-interface Vlan1
    aaa authentication login default fallback error local
    And it is currently working. On the radius server i also had to do this to make the users admins once logged in:
    https://supportforums.cisco.com/document/137181/nexus-integration-admin-access-free-radius

  • Command to see transmit qeueing drops in Nexus 5548

    Hello, 10g links in our core are getting rather congested as seen by MRTG graphs. Any command on Nexus 5548 to show transmit queuing drops on a given interface?

    You could use #show queing interface eth 1/1
    it shows you output similar as below:
    NEXUS-1# show queuing interface ethernet 1/1
    Ethernet1/1 queuing information:
      TX Queuing
        qos-group  sched-type  oper-bandwidth
            0       WRR            100
      RX Queuing
        qos-group 0
        q-size: 470080, HW MTU: 9216 (9216 configured)
        drop-type: drop, xon: 0, xoff: 470080
        Statistics:
            Pkts received over the port             : 222434
            Ucast pkts sent to the cross-bar        : 199674
            Mcast pkts sent to the cross-bar        : 22760
            Ucast pkts received from the cross-bar  : 101087
            Pkts sent to the port                   : 145083
            Pkts discarded on ingress               : 0
            Per-priority-pause status               : Rx (Active), Tx (Inactive)
      Total Multicast crossbar statistics:
        Mcast pkts received from the cross-bar      : 43996

  • Nexus 5548 L3 daughter card flapping

    Hi guys,
    Anyone of you here that experienced the logs below on their Nexus box:
    2011 Dec 12 06:24:45 GDCNXS5K01 %BTCM-2-BTCM_LOG_ROUTER_ERR: router card in slot 3 has internal link(s) flapped:     router ports down: 0x1a108000 0x1a109000 0x1a10a000 0x1a10b000 0x1a10c000 0x1a10d000 0x1a10e000 0x1a10f000
    I am getting this log at least once a day. Seems like it is shutting down the SVI of the box after the said log occured. Good thing I have enable vPC and I am able to access the NXS5K through the vCP keepalive link (mgmt).
    I have two Nexus 5548, but only one is experiencing the said error.
    Any inputs, suggestions would be greatly appreciated.
    Thanks,
    Edzel

    We had this same problem this past weekend, only in module 2 on a 5596.
    In our case, we had rebooted our primary Nexus and found the following message immediately preceeded the BTCM error you noted:
    %$ VDC-1 %$ %NOHMS-2-NOHMS_DIAG_ERROR: Module 2: Bootup diag detected major event: Forwarding ASIC failure: Ethernet2/9 Ethernet2/10 Ethernet2/11 Ethernet2/12 Ethernet2/13 Ethernet2/14 Ethernet2/15 Ethernet2/16
    We replaced the module.  A "show diag results module 3" would probably show you the same thing.  However, I don't think the error message will show up until you reboot.
    If your flapping Nexus is secondary, you probably won't notice anything major, but if it is your primary, it would probably affect your routing.

  • Servers connected to Nexus 5548 only getting 200 Mbps of throughput

    Servers connected to NExus 5k were only getting 100 Mbps of throughput. So I disabled Flow control recieve on all the ports. After this we are getting 200 Mbps of speed. The servers are connected throuh 10 gig port. Could you guys please suggest why the throguhput is still low? Atleast we should get 1Gbps of thrpoughput.

    Hi Adam,
    I think we probably need a little more information to go on. Can you answer the following?
    What type of servers and NICs?
    What OS are you running on the servers?
    What cables do you have from the servers to the switch?
    Are the two servers in the same subnet or is the traffic between them routed?
    If routed, is that in the Nexus 5548 or some other router?
    How are you testing throughput?
    Presumably you're not seeing any errors on the switch ports that the servers are connected to?
    Regards

  • Configuring FET-10G-SR for NEXUS 5548/2248

    Hey everyone-
    I am a little newer with configuring switches and routers, and I have been asked to troubleshoot a FET-10G-SR in our NEXUS 5548 and NEXUS 2248.  I am aware that the ports need to be configured to except FET parts, and I have tried using the "switchport mode fex-fabric" command to configure the ports, but the command will not work for some reason. Can anyone help me with configurations step by step to have these parts work properly? Any help will be greatly appreciated. Thank you!
    Chris Hazell

    It should normally work unless the port is not the proper type of has a configuraiton applied that's incompatible.
    Can you provide the output for "show run int eth ___" and "show int eth___" (substituting your interface number for the "___") for the interface in question?
    Also, if it's the first fex you are adding, you must have enabled "feature fex" globally.

  • Nexus 5548 Layer 3 daughter card insertion

    Hello there,
    I am planning to install Nexus 5548 Layer 3 daughter card. I found the hardware removal procedure on Cisco website but it doesn't say whether it's hot plugged or not. (Since I've to remove existing L2 module so I guess the box needs to be powered off but not sure). Has anybody had the experience in doing the upgrade to share?
    Thanks in advance
    Regards,
    Chinnawoot 
    PS. Detail of the running system
    Cisco Nexus Operating System (NX-OS) Software
    TAC support: http://www.cisco.com/tac
    Copyright (c) 2002-2014, Cisco Systems, Inc. All rights reserved.
    The copyrights to certain works contained in this software are
    owned by other third parties and used and distributed under
    license. Certain components of this software are licensed under
    the GNU General Public License (GPL) version 2.0 or the GNU
    Lesser General Public License (LGPL) Version 2.1. A copy of each
    such license is available at
    http://www.opensource.org/licenses/gpl-2.0.php and
    http://www.opensource.org/licenses/lgpl-2.1.php
    AUUT05TRUSDS03# show ver
    Cisco Nexus Operating System (NX-OS) Software
    TAC support: http://www.cisco.com/tac
    Documents: http://www.cisco.com/en/US/products/ps9372/tsd_products_support_series_home.html
    Copyright (c) 2002-2014, Cisco Systems, Inc. All rights reserved.
    The copyrights to certain works contained herein are owned by
    other third parties and are used and distributed under license.
    Some parts of this software are covered under the GNU Public
    License. A copy of the license is available at
    http://www.gnu.org/licenses/gpl.html.
    Software
      BIOS:      version 3.6.0
      loader:    version N/A
      kickstart: version 7.0(1)N1(1)
      system:    version 7.0(1)N1(1)
      Power Sequencer Firmware:
                 Module 1: version v2.0
                 Module 3: version v2.0
      Microcontroller Firmware:        version v1.2.0.1
      SFP uC:    Module 1: v1.0.0.0
      QSFP uC:   Module not detected
      BIOS compile time:       05/09/2012
      kickstart image file is: bootflash:///n5000-uk9-kickstart.7.0.1.N1.1.bin
      kickstart compile time:  3/19/2014 14:00:00 [03/20/2014 10:09:46]
      system image file is:    bootflash:///n5000-uk9.7.0.1.N1.1.bin
      system compile time:     3/19/2014 14:00:00 [03/20/2014 13:54:43]
    Hardware
      cisco Nexus5548 Chassis ("O2 32X10GE/Modular Universal Platform Supervisor")
      Intel(R) Xeon(R) CPU         with 8253860 kB of memory.
      Processor Board ID FOC172441CQ
      Device name: AUUT05TRUSDS03
      bootflash:    1966080 kB
    Kernel uptime is 172 day(s), 21 hour(s), 56 minute(s), 9 second(s)
    Last reset at 126063 usecs after  Wed May 21 12:35:50 2014
      Reason: Reset Requested by CLI command reload
      System version: 7.0(1)N1(1)
      Service: power-sequence cycled
    plugin
      Core Plugin, Ethernet Plugin
    AUUT05TRUSDS03# show lic usage
    Feature                      Ins  Lic   Status Expiry Date Comments
                                     Count
    FCOE_NPV_PKG                  No    -   Unused             -
    FM_SERVER_PKG                 No    -   Unused             -
    ENTERPRISE_PKG                No    -   Unused             -
    FC_FEATURES_PKG               No    -   Unused             -
    VMFEX_FEATURE_PKG             No    -   Unused             -
    ENHANCED_LAYER2_PKG           Yes   -   Unused Never       -
    LAN_BASE_SERVICES_PKG         No    -   Unused             -
    LAN_ENTERPRISE_SERVICES_PKG   No    -   Unused             -

    I ended up getting the answer from TAC. First put in these two commands:
    test ethpm l3 enable-show-iport
    test port-channel l3 enable-show-ipc
    Then you will get some new port channels showing up (127 and 128).
    I'm not sure what 128 is for, but 127 is the internal port channel for the L3 card. Then you can view stats and poll with SNMP against the interface...
    show interface port-channel 127

  • Link Error Nexus 5548

    Hi All,
    I have issues with Nexus 5548 ports 1000Gb ports. They go down after sometime with the error " Link not connected " while the links are connected. When i move the connections to other ports they work but after a while the go down again with the same error. I can confirm that is currently down was working and its currently connected. Has anyone seen the error before?
    Kindly see the output from the interface thats currently down below:
    VNX_NEXUS# sho interface eth1/11
    Ethernet1/11 is down (Link not connected)
      Hardware: 1000/10000 Ethernet, address: 002a.6a71.1f92 (bia 002a.6a71.1f92)
      Description: Link_to_EMC_RPA3
      MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec
      reliability 255/255, txload 1/255, rxload 1/255
      Encapsulation ARPA
      Port mode is access
      auto-duplex, 1000 Mb/s, media type is 10G
      Beacon is turned off
      Input flow-control is off, output flow-control is off
      Rate mode is dedicated
      Switchport monitor is off
      EtherType is 0x8100
      Last link flapped 2d23h
      Last clearing of "show interface" counters 5w6d
      30 seconds input rate 0 bits/sec, 0 packets/sec
      30 seconds output rate 0 bits/sec, 0 packets/sec
      Load-Interval #2: 5 minute (300 seconds)
        input rate 0 bps, 0 pps; output rate 0 bps, 0 pps
      RX
        43384443 unicast packets  30 multicast packets  1496 broadcast packets
        43385969 input packets  7837558138 bytes
        0 jumbo packets  0 storm suppression bytes
        0 runts  0 giants  0 CRC  0 no buffer
        0 input error  0 short frame  0 overrun   0 underrun  0 ignored
        0 watchdog  0 bad etype drop  0 bad proto drop  0 if down drop
        0 input with dribble  0 input discard
        0 Rx pause
      TX
        56587244 unicast packets  3937125 multicast packets  1487058 broadcast packets
        62011427 output packets  14141808286 bytes
        0 jumbo packets
        0 output errors  0 collision  0 deferred  0 late collision
        0 lost carrier  0 no carrier  0 babble 0 output discard
        0 Tx pause
      18 interface resets

    Hi Leo,
    What confuses me is that the connection was working. I used the correct cable and the port type as well. How do i resolve this?

  • Upgrading Nexus 5548

    Hi,
    We want to upgrade our pair of Nexus 5548 to the new NX-OS 5.1(3)N2(1a) from the 5.0(3)N1(1c) version. We would like to use the ISSU procedure. But when we execute the command "show spannig-tree issu-impact" we get the following output:
    No Active Topology change Found!
    Criteria 1 PASSED !!
    No Ports with BA Enabled Found!
    Criteria 2 PASSED!!
    List of all the Non-Edge Ports
    Port             VLAN Role Sts Tree Type Instance
    Ethernet2/8      1803 Desg FWD  PVRST      1803
    The 1803 vlan is only used for the peer-keepalive link and it only exists on these two Nexus. So one of the two Nexus needs to be the STP root. That makes the ports on that vlan to be in designated-forwarding state, which is not supported for the ISSU:
    sh run int e2/8
    !Command: show running-config interface Ethernet2/8
    !Time: Fri Jun  8 17:04:33 2012
    version 5.0(3)N1(1c)
    interface Ethernet2/8
      switchport access vlan 1803
      speed 1000
    That is the only port that belongs to that VLAN and it is directly connected to the other Nexus 5548. So the only way we see to avoid this port of being in designated-forwarding state is to apply the "no spanning-tree vlan 1803" command. Would it be a problem?
    We can imagine that introducing the "spanning-tree port type edge" should not be a good idea, shouldn´t it?
    Thank you very much for your help!
    Josu

    Hi,
    Reviewing all the prerequisites for the ISSU, we have seen the following:
    SSU and Layer 3
    Cisco Nexus 5500 Platform switches support Layer 3 functionality. However, the system cannot be upgraded with the ISSU process (non disruptive upgrade) when Layer 3 is enabled. It is required to unconfigure all Layer 3 features to be able to upgrade in a non disruptive way with an ISSU.
    We have the interface-vlan feature enabled. But it is only used for two interfaces:
    - interface-vlan 510 --> It is only used in order connect to the switch
    - interface-vlan 1803 --> The one used for the keepalive
    We could administratevely shutdown the interface-vlan 510. But we could not do so with the interface-vlan 1803, since it is used for the keepalive. If we execute "no feature interface-vlan", would the keepalive stop working?
    When we execute "sh install all impact ..." command the Nexus does not tell anything about this feature. Is really recommended to disable it? Is it needed for the ISSU procedure?
    Thank you very much in advance!!
    JOSU

  • Connectivity Issue between Nexus 5548 to VNX 5300

    Hi All,
    I am doing a lab setup where i want to connect Nexus 5548 UP to VNX 5300 storage directly. The physical connectivity is established between switch and storage but On Nexus the status of the port shows "linkFailure". I tried matching the port mode (like Auto, F) and speed but the port always shows "linkFailure".
    The connectivity from Nexus to VNX is FC.
    Anyone can suggest the root cause or any troubleshooting steps.
    Regards,
    Abhilash

    LinkFailure might be a GUI status.
    show interface fcx/y might say,
    Link failure or not connected
    The physical layer link is not operational.
    This means the switch is not detecting light, so the phyiscal layer is the cable and lasers (sfp's, HBAs or whatever adapter the VNX uses).  It could mean you need to turn the interfaace up from the vnx side.

  • C220 M4 w/ VIC1225 and Nexus 5548

    I have four UCS C220 M4 servers that each have a VIC 1225 and are connected up to a Nexus 5548.  I have set them to trunk ports and have set the appropriate VLANs in ESX and the portgroups.  I can ping the gateway and other hosts on the network, but for some reason I can't ping any of the other C220 M4 servers that have a VIC1225.  All of the C220's can ping other devices on the network, but not each other.  Is there some setting I need to modify on the VIC or switch?  Currently the VIC is running as Classical Ethernet mode.

    There is no special configuration to make connectivity work in the rack servers, I assume these servers are in standalone mode and not integrated with UCSM.
    What L3 device is doing your Inter-Vlan routing? Is it the N5K these servers are connected to or there is another device doing this job?   If it is the N5K, are all the servers in the same network segment? I mean, is there a single SVI or multiple?  can your Nexus 5K ping each of the servers?
    -Kenny

  • Creating VPC's between 2 NExus 5548's

    I am just about to setup my 2 Nexus 5548's in the
    lab for VPc. I see that I have to setup an etherchannel using 2   10 gig ports for the Peer link and
    I also have to setup a Peer keepalive.
    Do I also have to burn a 10 gig port on both switches for this keepalive ?
    I dont have any 1 gig ports on these switches.
    Any help would be appreciated.
    Cheers
    Dave

    The best way is to connect the mgmt0 ports to a CORE switch for out of band management. Also, when you configure the vrf context management, make sure you specify a route to the management subnet via vrf management.

  • Connecting IBM v7000 to Nexus 5548

    20-Sep-2012 16:51 (in response to feisalb)
    IBM V7000 with Nexus 5548UP and Nexus 4000 Design/implemetation guide
    Hi Guys
    I have a question in regards to connecting IBM v7000 directly to Nexus5548.
    CAN WE DO THIS?
    Our current setup is IBM v7000 -> MDS 9124 -> Nexus 5548.
    But our MDS 9124 are out of warranty now and we need to take them out of production. And only way we can do this is if we connect our IBM v7000 fibre ports directly to our Nexus 5548.
    Can someone please point me to the right direction any knowledge base articles etc.
    Thanks Heaps
    Sid

    Dear prkrishn
    I am working on the Data Center Solution between two Data Center, details underneath
    DC 1 Site
    1. 2 x DC Core Switch (Nexus 7009) - will be used for Servers, Application, IBM V7000, Database, etc.
    2. 2 x Network Core Switch (Cisco 6509) - Handle Campus and Inter Building connection.
    3. IBM V7000 (SAN)
    DC 2 Site
    1. 2 x DC Core Switch (Nexus 7009) - will be used for Servers, Application, IBM V7000, Database, etc.
    2. 2 x Network Core Switch (Cisco 6509) - Handle Campus and Inter Building connection.
    3. IBM V7000 (SAN)
    With the above mention setup, can I configure FCIP between DC1 & DC2 using Nexus 7009? or I need FCIP capable Switch such as IBM SAN Switch (SAN06-BR), I was wondering if I can configure FCIP on Nexus 7009 DC Switch.
    Hoping for your kind response at earliest.
    Kind Regards,
    Arnold

Maybe you are looking for

  • Date Mismatch of Planned Orders and Production Orders in APO & ECC

    Dear APO Experts When i am performing /SAPAPO/CCR , we are getting errors for Few Materials Please kindly advice. Following error for Planned Orders: Order 0026037355 difference for receipt date:    06.02.2012 01:05:53(APO) <-> 04.02.2012 01:05:53 Me

  • Windows SBS 2011 - I can't add a new user through the SBS Console

    I have recently installed SBS 2011 and this is my first install of SBS since 2003. After the installation I went to the SBS Console to add a new user and when I select 'Add a new user account' and base it on the Standard User account i get a message

  • Essbase Memory issue

    Hi All: I have an Essbase BSO cube with 35 G of page files and 6 G of index files. The version is 11.1.2.2. The data cache setting is 8G. The index cache setting is 6G. Now the issue is the memory for the essvr.exe service is about 16G and the memory

  • Can we call Remote Endable Module  from another Remote Enabled Moduel

    Hii experts... I have a problem regarding Remote Enabled Module Function Module.... Actually i want to call the standard BAPI 'BAPI_GL_GETGLACCBALANCE' into the BAPI which i hve created... is it possible??? or can anyone tell me if it is not possible

  • Shooting 24P Need final output to be XDCAM 1440x1080i60

    I will be cutting spots shot at 24P and some variable High Speed frame rate footage. My final output needs to be 1440x1080i XDCAM format. What is the best sequence settings to work with? Does the footage need to be converted before cutting or should