File adapter not reading (not starting polling interval)

Hello,
I've got one communication channel trying to read a file each 10 seconds.
The file adapter is configured correctly and the channel is started but sometimes it stops the polling interval process and I don't know why.
For example the channel was working fine until Friday but with no reason it stopped to attempt to read the file on the directory... what can it be?
And another question. What's the difference about communication channel with "Automatic control" or "Started" manually?

Hi,
And another question. What's the difference about communication channel with "Automatic control" or "Started" manually?
Whenever you create new communication channel in Integration directory and activate it,its status in control data is Automatically and whenever you change it in RWB (Stop/Start) its status changes to Mannually.
Thanks!

Similar Messages

  • FILE ADAPTER NOT READING FILE.

    HI, GUYS.
    I'M USING A FILE ADAPTER TO READ A FILE THAT HAVE 4 REGISTERS AND EACH REGISTER ONLY HAS ONE FIELD THAT IS NUMBER TYPE.
    I CREATE THE FILE ADAPTER, AND I LET BPEL TO CREATE THE SCHEMA. THE IDE CALLS THES FIELD "C1". I ALSO CONFIGURE THAT THE FILE THAT MUST RAD IS THE PATTERN "*.TXT" AND EVERY 5 SECONDS.
    THEN A CREATE A RECEIVE ACTIVITY THAT RECEIVES WHAT WAS READ FROM THE FILE ADAPTER IN A VARIABLE.
    THEN I CREATE AN ASSIGN ACTIVITY AND I ASSIGN THE VALUE FROM THE RECEIVE ACTIVITY VARIABLE TO A NUMBER VARIABLE THAT IS THE INPUT OF A WEB SERVICE.
    THEN I DEPLOY THE BPEL, AND I INITIATE IT, BUT I GOT AN ERROR THAT SAYS THAT THE FIELD "C1" IS EMPTY. SO LOOKS LIKE THE FILE ADAPTER IS NOT READING THE FILE. I WOULD THANK ANY HELP THAT YOU CAN BRING ME.

    caps off
    You're sure the interface of the fileadapter (client partnerlink) is the same as your data-file which needs to be picked up?
    can you paste the content of the file and the content of the xsd of the process.

  • Exe file will not start using a Measurement studio 2013 component

    Hello,
    I use Meausrement studio 2013 with visual studio 2012 and vbnet on windows 7.
    On a new project (windows form application), i use a form and a ScatterGraph component. I compile, no errors and it works fine. 
    Now, i try to start this application on a another Windows 7 station. (The framework 4.5 is installed on its station).
    The exe file is in a directory with the natrional Instruments dll files.
    The exe file will not start, no errors.
    PS: Before, with Meausrement studio 2010 and visual studio 2010 all worked fine. 

    Hi, virgule
    It sounds like you are using the "Publish" feature in Visual Studio (a.k.a., ClickOnce) for deployment, is that correct? If so, unfortunately ClickOnce is not supported by Measurement Studio components.
    If you are looking for a good way to deploy Measurement Studio applications, I would highly recommend upgrading to Measurement Studio 2015, which ships with Measurement Studio Installer Builder. You can read more about this here: http://www.ni.com/white-paper/52669/en/
    If you cannot update to Measurement Studio 2015 and are using Visual Studio 2013, NI recommends using WiX for creating your installer. More information on WiX deployment can be found here: http://digital.ni.com/public.nsf/allkb/764B727C9BD2C4C686257C970053D059
    Thanks,

  • JCBC Adapter and File adapter not processing messages

    Hi
    I noticed that messages are being delivered to Adapter engine and the same are visible in Runtime Workbench with status "to be delivered". But, JDBC Adapter and File Adapter not processing these messages.
    Any idea where I can find the problem?
    I was able to re-deliver successfully via the JDBC Adapter using the MessagingSystem GUI using XISUPER user.
    Regards
    Chandu

    Hi,
    1.Status: TO_BE_DELIVERED
    Which means that the message was successfully delivered from Integration Server point of view and it states that the messages is initially handed over to the Messaging System.
    TO_BE_DELIVERED occurs while the message is put into the Messaging System receive queue.
    Regards
    Agasthuri Doss

  • File Adapter and reading all XML files from direcotry

    Problem occurs on PI 7.1
    I defined sender file adapter. File name mask is: "*.xml" to read all XML messages from directory.
    Quality of service is: Exactly One.
    Poll Interval: 30
    Retry interval: 30
    Processing mode: Archive with option "Add Timestamp".
    Processing sequence: by name.
    I though that with above configuration my File Adapter will be reading folder for all coming XML files. But  somehow it is reading XMLs only when I'm activating it in Integration Builder.
    Any idea what can cause such strange problem?

    Hi Tomasz,
    As per my understanding, you need to activate the file adapter for reading the XML files on your directory. Right?
    If that is the case, then the issue might be with the Cache.
    1. Clear the cache from the Integration Builder.
    2. Check in SXI_CACHE whether there are any issues. Click on Delta Cache refresh to find out if there are any cache related issues.
    Thanks,

  • Invoke File Adapter to read just once.

    Hello all,
    I want to invoke a partnerlink which is using File Adapter to poll for a file every fixed interval. I want the File adapter to read the file just once. In other words, what would be the behaviour of the File Adapter when i invoke it syn or asyn way? Would the file adapter read the file only once? Is there anyway to do this? I read in some post about it but i cannot find or recall the thread.
    Thanks for your help.

    I think I need to explain the scenario in order to give you some more idea as to why i need to poll file just once.
    I am trying to create a schedular using Quartz and If i have this BPEL process scheduled to trigger at say some time, the process would keep on polling. Whereas i just need to poll when the trigger is fired that is once per every trigger fired.
    Can anybody throw some ideas on this?

  • File Adapter to read from remote file server query

    Hi all,
    I want a SOA 11g application to read files on remote server using File Adapter. Is it possible to configure the File Adapter to read from remote location instead of locally. Is it possible. Is yes where can I find the associated remote file configuration documentation.
    Thanks
    Edited by: user5108636 on 19/09/2010 19:49

    I also changed one more properties the FTP connection factory called serverType=win. I get bits and pieces in each document. Is there any working example to connect to an FTP server running on Windows using Ftp Adapter. Still not working.
    These are the error logs related to it. Please suggest
    ####<Oct 12, 2010 1:17:22 PM EST> <Info> <Common> <server_name> <WLS_SOA> <[ACTIVE] ExecuteThread: '7' for queue: 'weblogic.kernel.Default (self-tuning)'> <<WLS Kernel>> <> <46e7c258a0e5cad6:-145e5cdb:12b99475c2b:-7ffd-0000000000046afa> <1286849842995> <BEA-000628> <Created "1" resources for pool "eis/Ftp/FtpAdapter", out of which "0" are available and "1" are unavailable.>\
    [2010-10-12T12:56:07.142+11:00] [WLS_SOA] [NOTIFICATION] [] [oracle.soa.adapter] [tid: weblogic.work.j2ee.J2EEWorkManager$WorkWithListener@170e13a9] [userId: weblogic] [ecid: 0000IiTsVSi9xWD_n91FiZ1CfLfc00006s,1:24709] [APP: soa-infra] [dcid: 46e7c258a0e5cad6:f9faea1:12b852b7f0f:-8000-00000000000005ed] FTP Adapter FetchAvlFiles Recovery still not possible after 1500 attempts due to javax.resource.spi.IllegalStateException: [Connector:199176]Unable to execute allocateConnection(...) on ConnectionManager. A stale Connection Factory or Connection Handle may be used. The connection pool associated with it has already been destroyed. Try to re-lookup Connection Factory eis/Ftp/FtpAdapter from JNDI and get a new Connection Handle.
    Thanks
    Edited by: user5108636 on 11/10/2010 19:05
    Edited by: user5108636 on 11/10/2010 19:22

  • How to get file name using File adapter Sync read

    Hi All,
    I am using SOA 10.1.3.3 and JDEV 10.1.3.3.
    I have an async bpel process.
    I have to read file name in this process... so i have used file adapter sync read operation.
    How can we get the file name with out payload using sync read.
    For normal read (Inbound Spec)we have UseHeaders="true" property.
    Is there any property for sync read to read the file name.
    Please help me
    Regards
    PavanKumar.M
    Edited by: [email protected] on Oct 27, 2009 11:23 PM

    Hi Eric,
    The info in the link provided by you is for a normal read.
    I need to read he file name using Sync read operation.
    Regards
    PavanKumar.M

  • Sender file adapter not polling the file

    hi all,
    i have configured a filexifile scenario....
    but the file sender adapter is not polling the file at all....
    i dont c any message either in RWB or in SXMB_MONI
    i checked the adapter framework url at <i>http://<ximachine>;<port>/AdapterFramework</i>....and the status for the file adapter is green...
    but the message it gives there is
    <i>Sender Adapter v1014 for Party '', Service 'TASL_FILE_SENDER':
    Configured at 03:07:24 2006-02-02
    Up and running - no message processing until now
      last poll interval started 04:01:24 2006-02-02
      length 60,000 secs</i>
    y is the sender adapter not polling the file..
    i am using NFS as my File System....i gave the source directory as <i>d:/test_dir/</i>
    is this way of specifying the source directory on a windows machine correct...
    thanks
    pavan

    There is probably something wrong with the File Adapter.  You will need to go to the RunTime Workbench >> Component Monitoring >> Display >> Click on the Adapter Engine >> More information will display and click on the button 'Adapter Monitoring' >> A new window will display and click on the arrow next to your adapter engine.  This displays a list of adapters running on your system.  Green light means good; Red, you have a configuration problem.  Look at the error and try and resolve it.

  • File adapter not reading file suddenly

    Hi,
    My File to IDOC scenario was working properly. Suddenly the file adapter is not picking the file from the location. I have not changed any code. I checked all users, are in unlocked mode only. The log file throws error. Let me know any solution to resolve this
    ========
    1.5#001A4B4C508E007400000577000019F40004558D5E8AFB9D#1219965571787#/Applications/ExchangeInfrastructure/AdapterFramework/Services/Trex##com.sap.aii.af.service.trex.impl.Util.Util: getIndex()#J2EE_GUEST#0####02305f1074b511ddaa1a001a4b4c508e#SAPEngine_Application_Thread[impl:3]_27##0#0#Error#1#com.sap.aii.af.service.trex.impl.Util#Java###SLDException couldn't get the SLD instance name. Therefore the index ID couldn't be inititialized. - Message: ; To-String: .#2#Could not read SLD instance name, due to: undefSldAccessor#com.sap.aii.af.service.sld.SLDException: Could not read SLD instance name, due to: undefSldAccessor#
    #1.5#001A4B4C508E007400000579000019F40004558D5E8AFCB3#1219965571787#/Applications/ExchangeInfrastructure/AdapterFramework/Services/Trex##com.sap.aii.af.service.trex.TrexManager.TrexManager: getTrexConfiguration()#J2EE_GUEST#0####02305f1074b511ddaa1a001a4b4c508e#SAPEngine_Application_Thread[impl:3]_27##0#0#Error#1#com.sap.aii.af.service.trex.TrexManager#Java###TrexException: thrown by any problem related to the DataAccess: Message: .#1#Class: com.sap.aii.af.service.trex.TrexException : SLDException in Method: Util: getIndex(). Couldn't get the SLD instance name. Therefore the index ID couldn't be inititialized. - Message: Could not read SLD instance name, due to: undefSldAccessor; To-String: com.sap.aii.af.service.sld.SLDException: Could not read SLD instance name, due to: undefSldAccessor#
    #1.5#001A4B4C508E00740000057B000019F40004558D5E8AFDE1#1219965571787#/Applications/ExchangeInfrastructure/AdapterFramework/Services/Trex##com.sap.aii.af.service.trex.TrexScheduler.TrexScheduler: run()#J2EE_GUEST#0####02305f1074b511ddaa1a001a4b4c508e#SAPEngine_Application_Thread[impl:3]_27##0#0#Error#1#com.sap.aii.af.service.trex.TrexScheduler#Java###TrexException: thrown by any problem related to the Trex processing. Message: .#1#Class: com.sap.aii.af.service.trex.TrexException : TrexException in Method: TrexManager: getTrexConfiguration(). Thrown by any problem related to the DataAccess. Message: Class: com.sap.aii.af.service.trex.TrexException : SLDException in Method: Util: getIndex(). Couldn't get the SLD instance name. Therefore the index ID couldn't be inititialized. - Message: Could not read SLD instance name, due to: undefSldAccessor; To-String: com.sap.aii.af.service.sld.SLDException: Could not read SLD instance name, due to: undefSldAccessor#
    ========

    Hi,
    1)Stop and start the Communication Channels.
    2) Activate the scenario.
    3) If u r using FTP may be ur credentials wereexpired.check the credentials.
    "Award Points if helpful"
    Regards,
    jayasimha

  • File Adapter not able to read quotes after pipe

    I have flat file delimited by pipe |, and optionally enclosed by " quot, below is the xsd definition
    "<xsd:element name="vtext" type="xsd:string" nxsd:style="terminated" nxsd:terminatedBy="|" nxsd:quotedBy="&quot;"/>"
    <Field Before>|"TRANS" IN TRANS FAT SHOULD APPEAR IN ITALICS MH|<FieldAfter>
    the file adapter fails to read |", but if I put a space between them, all works well. But, if it is continuous it fails to read resulting in an error.
    any help in reading such a string in nxsd would be of great help..
    thanks,
    Shailesh

    Can you please give us a before and after?
    I am guessing you want to read the text with the pipes?
    If thats the case try this:
    "<xsd:element name='element1' type='xsd:string'
    nxsd:style='surrounded' nxsd:surroundedBy='|' /> "
    Replace the single ticks with double ticks. For some reason it does not display well in the forum.
    Edited by: soa_adf on Apr 13, 2012 11:29 AM
    Edited by: soa_adf on Apr 13, 2012 11:29 AM

  • File Adapter Not Reading Large Files

    Dear Experts,
    Enviornment :-
    OS:-Linux
    Jdeveloper:- 11.1.1.6
    SOA:-11.1.1.6
    Weblogic:-10.3.6
    JDK:-SUN
    Allocated RAM:-16GB
    Currently we are in UAT Phase and now we are facingan  issue in reading large file.Below is the Design details of the service
    FileAdapter(Read)-->Bpel(Business login,Using FlowN)-->FileAdapter(Write CSV),JMS Adapter(AQ JMS topics)
    In this case at the time of read itself we are facing issue. File adapter reading xml file but in receive activity receives input data as
    xmlDocKey:1C135990067411E3BFA6B5087B629F9DI
    I really couldn;t understand about the error. Even i tried reading as Opaque format and still end up with same error.
    In order to make sure i have create mediator and tried reading the file, in case i was able to read file upto 15mb with out any error.Also i tried as  "read as Attachment" in Bpel component and able to read the attachment upto 7 mb file, but this is hitting the performance side.
    I request some one please let me know why the file adapter is giving XmlDOCKey rather then XMLContent to the inputvariable
    Regards,
    Tarak

    Can you check your BPEL Properties in EM?
    Go to Soa-infra > right Click > SOA Administration > BPEL properties
    increase the Dispatcher Engine Thread = 10, Dispatcher Invoke Threads = 60 and Dispatcher Engine Threads to 90
    Click on "More BPEL Configuration Properties"
    Increase the  DispatcherMaxRequestDepth from 600 to 1000.
    Bounce the server and see if works..
    Bounce the server and try again.
    If this fails, try get a threshold by increasing the file size until it fails again. 

  • How to add do not read file content option inside File Adapter (Synch Read)

    Hi,
    Is there any way, that I can skip reading the file content inside file adapter with operation as Synchronous Read ( I just want to read the file name and directory and if the file name matches with the input variables then I have to delete the files, for this i am using FA with synch read operation, everything is fine like deletion, but it is reading the file content and storing it in DB, i dont want this) .

    This will solve your problem.
    http://docs.oracle.com/cd/E23943_01/integration.1111/e10231/adptr_file.htm#CHDHIEBI
    HTH.
    Puneet.

  • Sender File Adapter Not Showing in Decentral Adapter Engine

    Hi,
    We have recently implemented a Decentral Adapter Engine on a windows box. The adapter engine seems to be working fine because my adapters show and seem to work fine in it.
    However, when I define a Sender File Adapter that uses File Content Conversion message protocol instead of just File messaeg protocol, the adapter does not show up in the decentral adapter engine.
    I made sure that Adapter Engine parameter in the Sender File Adapter shows the new adapter engine but that does not seem to be working. If change the Adapter Enginer parameter to show the Central Adapter Engine, then I can see the Sender File Adapter on the Central Adapter engine and it works fine. (Note: The Central Adapter Engine is installed on a Unix box) 
    Here are the paramters I defined for the Sender File Adapter:
    - Transport Protocol: File System (NFS)
    - Message Protocol: File Content Conversion
    - Adapter Engine: (new Adapter Name)
    Source Directory: (
    server/drive/path)
    File Name: purchaseOrder.txt
    Quality of Service: Exactly Once
    Poll Interval (secs): 60000
    Poll Interval (msecs):
    Retry Interval (secs):
    Processing Mode: Archive
    Add Time Stamp (checked)
    Archive Direcotry: (
    server/drive/path/archive)
    Process Read-Only files: (not checked)
    Processing Sequence: By Name
    Fiel Type: Text
    File Encoding:
    Operating System Command:
    Additional Files (not checked)
    Content Conversion Parameters
    Document Name: MT_Request_File_Data
    Document Namespace: http://nxy.tots/fg_admin
    Document Offset:
    RecordSet Name: Purchasing
    RecordSet Namespace:
    RecordSet Structure: Purchase_Record,*
    RecordSet Sequence: Ascending
    RecordSets per Message: 1
    Key Field Name:
    Key Field Type: String(Case-Insensitive)
    Purchase_Record.fieldFixedLengths: 8,4,2,10,10,12,18,12
    Purchase_Record.fieldFixedType: char
    Purchase_Record.fieldNames: Request_Action,Request_PO_Num,Request_PO_LN,Request_PO_Date,Request_Purchasing_Org,Request_Purchasing_GName,Request_Created_By,Request_Vendor_Name
    Purchase_Record.fileContentFormatting: trim
    Adapter Status: Active
    Advanced Mode: (not checked)
    Your help is much appreciated.

    Hi Alaa,
    look into this document:
    http://service.sap.com/nw-howtoguides -> Exchange Infrastructure -> Troubleshooting: Adapter Engine 3.0 (Expert Call slides)
    If the File Adapter works without conversion, then you should count the number of fields in a row. If it differs from the configuration, then it runs on error.
    Another idea is to check the content type of the file. When you do not enter a File Encoding, then the file adapter assumes utf-8. If the file is for example latin-1, then the number of characters in a row are not counted correctly.
    Regards
    Stefan

  • Sender File Adapter Not Picking Any File

    Dear Expert,
    I am newbie in PI. Just tried to create File Content Conversion Scenario. Details as follow :
    1. Source Directory ..\file\log\test_q.txt
    2. Target Directory  ..\file\log\xml\test_q.xml
    Transport Protocol : NFS
    Message Protocol : File Content Conversion
    Adapter Engine    : Integration Engine
    I have completed all the design and configuration in IR and ID. However, when I produce the log file in the directory, nothing happen.
    Hacing checked in the RWB as well, I could not find any clue. simply nothing happen.
    Would you please advise me on how to trigger the interface? As per my understanding, sender file adapter will be activated directly once the file is created.
    Thank you very much in advance.
    Best Regards,
    Y

    Hi Yonisiwa,
       Things you should check here are:
    1) If the sender file adapter is active or not.
    2) If the source directory is correctly spelt or not. (Check if you are using the correct slash \ or /)
    3) The file name/mask is correct or not.
    4) The polling interval is too long.
    Alternatively, you can check the message monitoring in RWB at the adapter level and go into the audit log if the message.
    There you can see the reason for the file not being picked up.
    Also check the Communication Channel status in the Component Monitoring link in RWB.
    Regards,
    Ravi Kanth Talagana