How do I measure temperature from 4 RTDs simultaneously?

I am trying to set up a systerm that requires multiple temperature measurements. I am able to make one RTD measure. But if I mirror the same code to create two measurements, i am getting an Error - 50103 "the specified resource is reserved". I have just begun using LabVIEW, so any and all help is valuable. If there is already material available on this topic, would you direct me there please.
Solved!
Go to Solution.

Yup read Multi-channel Single Sample with a single task.
That being said this won't be "simultaneous".  That implies at the same instant in time all 4 will be read.  This just won't be true without a simultaneous sampling card.  Without that card your readings will likely be fraction of a milliseconds appart and for temperature that should be more than enough.  How much can temperature change in 0.001 seconds?  But for other signal types like trying to read a phase off set in a sine wave you will need a true simultaneous sampling card.
Unofficial Forum Rules and Guidelines - Hooovahh - LabVIEW Overlord
If 10 out of 10 experts in any field say something is bad, you should probably take their opinion seriously.

Similar Messages

  • How can i measure temperature using thermocouple using labview?

    please  list out the procedures to be followed to measure temperature using thermocouple using labview.

    Do a search in the LabVIEW Example Finder (Help->Find Examples).  There are a ton of simple Analog Input examples in there using DAQmx.  One you might be most interested is "Thermocouple - Continuous Input.vi".
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • How do I measure RPM from a magnetic pick up?

    I have a Red Lion RPM display with a hall effect sensor connected to it. From what I've read This sensor/display setup passes a current through the pickup and measures the voltage generated by the rotating shaft to determine RPM.The problem I am having is my daqboard (PCI-6025E) counter won't measure the AC pulse of the sensor output. I currently use the ac output of the counter connected to an analog input and have it scaled for 1.6 v to 3.2 volts ac equals 400 to 2500 RPM.Is there a signal conditioning board I could use to convert the ac pulse to a 5 volts ttl pulse the daqboard can use?I've tried using a schmitt trigger, but I can't get an output from the trigger.

    ; ;lgfh;lgf;lkgf,
    One option would be to use the analog triggering on one of our full featured E Series data acquisition boards to trigger a digital pulse as outlined in the following Knowledge Base:
    http://digital.ni.com/public.nsf/websearch/67CCAAF13C8617FC86256E01006C3D69?OpenDocument
    Another option would be to purchase some of our SSR Series input modules. These modules convert AC and DC voltages to a TTL logic signal. If a voltage is within the selected input range, the SSR module returns logic low. Otherwise, the SSR module returns logic high.
    Whether you choose to go with the full featured E Series DAQ board or the SSR modules I recommend contacting our internal sales department at 1-800-433-3488 since they are wonderful at specifying systems.
    Am
    es
    Applications Engineering
    National Instruments

  • How to import measurment data from a Excel File to Citadel DataBase?

    A Microsoft Excel File is being created in a PC and I want to include that flie´s data into my citadel Database wich is in another PC.

    I give a example "Importing Spreadsheet Data to the Citadel Database" in the LabVIEW Version 6.1 and LV-DSC 6.1.
    LabVIEW 7.0 with LV-DSC you must in the ini file "DSCEngine.ini"
    set NoShutdownLog=1 and UseServerTimestamps=TRUE.
    kind regards
    amcholger
    Attachments:
    Write_File_to_Citadel_Example.zip ‏139 KB
    Write_File_to_Citadel_VI_Server.zip ‏289 KB

  • Measuring voltage from thermocouples

    How do i measure voltage from a thermocouple which is joined to another one. Meaning that they have a common point. I have tried reading in a voltage from 1 point and then subtracting it with the other but it does not give me the reading the multimeter is showing

    Hello,
    For troubleshooting bad readings, probably the first thing to do would be to check the board's configuration.
    Is it configured in differential mode? Differential mode is the most recommended mode for thermocouple readings. When using differential mode, just make sure to connect the positive lead of the thermocouple to ACH0 (for example), and the negative to ACH8.
    Once you have all the signals connected to your DAQ board, try running a MAX Test Panel. I usually run it using Continuous Mode. Before starting the acquisition, check the input limits in MAX, adjust them according to the input signal so that the board applies the appropriate gain.
    Finally, create a Virtual Channel (by taking into consideration the thermocouple type). Are you re
    ading the correct temperature? Is the CJC in your terminal block enabled? It's always easier to compare the temperature than the millivolts readings.
    I hope these tips help. Good luck with your application!

  • How to retrieve the values from a table if they differ in Unit of Measure

    How to retrieve the values from a table if they differ in Unit of Measure?

    If no data is read
    - Insure that you use internal code in SELECT statement, check via SE16 desactivating conversion exit on table T006A. ([ref|http://help.sap.com/saphelp_nw70/helpdata/en/2a/fa0122493111d182b70000e829fbfe/frameset.htm])
    If no quanity in result internal table
    - There is no adqntp field in the internal table, so no quantity is copied in itab ([ref|http://help.sap.com /abapdocu_70/en/ABAPINTO_CLAUSE.htm#&ABAP_ALTERNATIVE_1@1@]).
    - - Remove the CORRESPONDING, so quantity will fill the first field adqntp1.  ([ref|http://help.sap.com/abapdocu_70/en/ABENOPEN_SQL_WA.htm])
    - - Then loop at the internal table and move the quantity when necessary to the 2 other fields.
    * Fill the internal table
    SELECT msehi adqntp
      INTO TABLE internal table
      FROM lipso2
      WHERE vbeln = wrk_doc1
        AND msehi IN ('KL','K15','MT').
    * If required move the read quantity in the appropriate column.
    LOOP AT internal_table ASSIGNING <fs>.
      CASE <fs>-msehi.
        WHEN 'K15'.
          <fs>-adqnt2 = <fs>-adqnt1.
          CLEAR <fs>-adqnt1.
        WHEN 'MT'.
          <fs>-adqnt3 = <fs>-adqnt1.
          CLEAR <fs>-adqnt1.
      ENDCASE.
    ENDLOOP.
    - You could also create another table with only fields msehi and adqntp and then collect ([ref|http://help.sap.com/abapdocu_70/en/ABAPCOLLECT.htm]) the data to another table.
    Regards,
    Raymond

  • How do I run a J-type thermocouple to the usb-6363 DAQ and program labview to measure temperature?

    I have a usb-6363 DAQ and a J-type non-contact thermocouple that I am looking to connect and measure temperature through. However, the DAQ does not have any T/C inputs, which is needed to measure in the thermocouple temperature. I am connecting the thermouple to an analog input (+/-) and I am not looking to buy an amplifier, converter or any other hardware. I believe there is a way to program labview to read in the voltages of the thermocouple and convert it into accurate temperature readings. Any help/ideas?

    Hello George,
    This tutorial should step you through the basic process of configuring the device and connecting the thermocouple:
    Tutorial: Connect Thermocouples to a Data Acquisition (DAQ) Device
    http://www.ni.com/gettingstarted/setuphardware/dataacquisition/thermocouples.htm#Connecting a Thermocouple to Your Device
    From there, there are a number of things you can do- I'd recommend taking a look at the LabVIEW shipping examples (Help>>Find Examples...) as well as the DAQmx getting started tutorials:
    Getting Started with NI-DAQmx: Main Page
    http://www.ni.com/white-paper/5434/en
    At first glance, the 6363 you're using should have enough resolution to acquire usable data from a thermocouple- if you attempt reading raw voltages be sure that the acquisition range is configured for +/- 0.1V, though.
    Regards,
    Tom L.

  • How to get temperature from digital camera in to controller

    how to get temperature from digital camera in polarising microscope using t95 controller without adc.dll
     

    Ask the manufacturer of your camera…
    What kind of answer do you expect?

  • I'm new to the LabView. How do I pass data from VI configured using Serial (CMTS using CLI commands to set Parameters ) to VI configured using GPIB(vecto​r signal analyzer ) to measure such as RF frequency or power on the instrument​? Thanks

    I'm new to the LabView. How do I pass data from VI configured using Serial (CMTS using CLI commands to set Parameters ) to VI configured using GPIB(vector signal analyzer ) to measure such as RF frequency or power on the instrument?
    I just want to set something on the front panel that will execute the Serial parameters first and then pass these settings to vector signal analyzer
    Thanks
    Phong

    You transfer data with wires.
    Frankly, I'm a little confused by your question. I can't think of any reason why you would want to pass serial parameters (i.e. baud rate, parity) to a GPIB instrument. Please explain with further detail and attach the code.

  • Can I measure temperature using 6013 & 68LPR?

    Hello, from hardware I've got Multifunction DAQ (6013) and Therminal Block (68LPR). From software I've got VI Logger (1.0.1) and NI-DAQ (6.9.3). Using this, can I measure temperature with K-Type therminals? (Everything is installed and ready to go)
    If yes, how can I connect K-Type therminal to thermal block? Are there any instructions on how to use VI Logger to perform similar task to this one?
    Also what I want is, the temperature that has been read (for an hour, every 5mins) to be written in a file. Is it possible to write to a file using VI Logger?
    Thank you!
    Regards Slav.

    Hello:
    I answered this questions over here:
    http://exchange.ni.com/servlet/ProcessRequest?RHIVEID=101&RPAGEID=135&HOID=50650000000800000041CA0000&UCATEGORY_0=_30_%24_12_&UCATEGORY_S=0&USEARCHCONTEXT_QUESTION_0=%2B6013+%2Btemperature&USEARCHCONTEXT_QUESTION_S=0
    Sincerely,
    Brooks B
    Applications Engineer
    National Instruments

  • Measuring temperatur​e using thermocoup​le and SCB-68 box

    I used thermocouple and SCB-68 box to measure temperature. But the readings were fluctuating around the expected value. So I removed the thermocouple and short-circuited the differential input channels. As expected, the voltage reading was not zero and also fluctuating. It seems that there was something wrong with the SCB-68 box. What might lead to this and how to solve this problem? Thanks.

    The problem could be either the SCB-68 or the DAQ card you are using to make the measurement. You should first ensure that the DIP switches (S1 - S5) of your SCB-68 are in the correct position for your application. Please refer to the SCB-68 User Manual for more information on this subject.
    SCB-68 68-Pin Shielded Connector Block User Manual
    http://digital.ni.com/manuals.nsf/websearch/74C86A​DEF0E4813F86256C84007CB3AB?OpenDocument&node=1180_​US
    What do you mean by fluctuating? Full swings from 10V to 10V? Hitting one rail? Close to 0V but looks like noise in mV or uV? If your fluctuation is very slight, for example off by a few millivolts, than you could be picking up noise or your board could need to be calibrated. You can read more about accuracy and
    calibration from the following web page:
    Calibration Solutions from National Instruments
    http://www.ni.com/support/calibrat/
    If you have an E-Series Card you may be interested in running our Online E-Series Diagnostic Utility. This utility takes about 3 minutes to run, will perform a calibration, and will generate a report of anything that may be wrong with your board.
    Online E Series Diagnostic Utility
    http://www.ni.com/support/selftest/
    Regards,
    Justin Britten
    Applications Engineer
    National Instruments

  • Can NI myDAQ ai0 and ai1 be connected directly with thermocouples to measure temperature???

    Hi,
    I am trying to use myDAQ to realize both temperature measurement and digital output.
    By reading this page I have learned that how I can create a task for temperature measurement using thermocouple with a certain NI device.
    http://www.ni.com/white-paper/14338/en/
    What I found to be really interesting is that when I create a task for myDAQ temperature measurement using a thermocouple when my NI myDAQ is connected with my PC, two AI ports ai0 and ai1 both appears in the create task window!!
    I never found any information from NI myDAQ manual that "AI0 and AI1" can be connected directly with a thermocouple to measure temperature without using additional conditioning system. But this window suggests that myDAQ can be used in this way, is it?
    I am still trying to do it this way, and I'll post some results here again.
    I would be really appreciate if anyone could confirm or disprove my guess. Thank  you.
    PS:
    Attached is the 

    Attached is the screenshots for "create new task" in NI MAX
    Attachments:
    1.JPG ‏60 KB
    2.JPG ‏64 KB

  • How to get Distinct Values from Answers

    Hi,
    How to get Distinct values from answers, i've tried to put some functions on it.
    Thanks,
    Malli

    Malli,
    Are you trying to fetch data from Dimension Attr OR Fact Measures? Did you try the advance tab - > Advanced SQL Clauses - > Check this box to issue an explicit Select Distinct.

  • How can I measure the hertz in a wave form?

    How can I measure the hertz in a wave form?

    As an example, this is from BBC Technical Requirements for HD material:
    3.1.1 Stereo line-up tones
    All stereo tracks must use EBU 1KHz tone (left ident). All tones must be sinusoidal, free of distortion and phase coherent between channels.
    Digital Audio Reference level is defined as 18dB below the maximum coding value (-18dBFS) as per EBU recommended practice R68.
    See also:
    http://www.bbc.co.uk/guidelines/dq/pdf/tv/tv_delivery_to_network_programmes_v1.2-2011.pdf
    for full document.
    And for BBC Radio:
    Not every Network requires tone. Check the delivery requirements with the commissioning network or click here.
    Reference tone, where used, should be at -18dBFS or PPM 4 on A, B and/or M.
    If submitting material with reference tone, tone and programme material must be have been monitored and measured through the same technical chain. The level of the tone must be equivalent to 0dBu and no less than 8dB below peak audio level for the programme material.
    THE LEVEL OF TONE MUST HAVE A KNOWN RELATIONSHIP WITH THE LEVEL OF THE PROGRAMME MATERIAL AND THIS MUST BE STATED; for example: “Tone at 8dB below peak programme level”.
    As a newcomer to digital sound (my background is camera) I confess to being somewhat confused. We are normally told to record at the highest level possible. So for voice podcasts I tend to record at about -6dB below peak for maximum volume, distributeds on MP3 files.
    But I can underatand that televison and radio especially for analogue transmission) may have limited headroom, hence the requirement for -18dB peak = 0dBM.
    I remember when we first rented out Digital Betacam cameras, some recordists were recording almost everything OVER -18dBM.
    I suspect that until we have an all-digital world, these requiremnents will still be in place.
    Many thanks to all. It's a ghreat community!
    Brian Rose

  • I've been deleting the info in the "Sort..." fields, but when I plug my iPod into my computer iTunes repopulates the fields I deleted.  How do I stop it from doing that?

    I've been deleting information I don't want in the "Sort..." fields (like getting rid of "Deluxe Edition" markers, etc.), but when I plug my iPod into my computer iTunes repopulates the fields I deleted.  This only happens for a few artists, and it's the same artists every time this happens.  How do I stop it from doing that?  It makes it measurably harder for me to control the organization of my library.

    Hi donfrommars,
    Welcome to the Apple Support Communities!
    Please use the following article for information and instruction on deleting the U2 album from your devices and account.
    Remove iTunes gift album "Songs of Innocence" from your iTunes music library and purchases
    Have a great day,
    Joe

Maybe you are looking for

  • SOAP to SOAP scenario testing

    Hi Experts, I have created SOAP to SOAP sceanrio. I have to test it wheather its working or not. please tell the full procedure how to test this. Thanks

  • Account assignment question (for subcontracting item category)

    Hello Is it possible to have a account assignment category with a consumption posting indicator V work with a subcontracting item category L? Our scenario is that a SD item category TAB auto generates a Subcontracting PO with account assignment M and

  • Office 2007 compatability for OS X

    I have an iBook 900MHz, and I can't open up my Office 2007 files from my windows computer on my Office Mac Word. With office 2007, they have changed all the file extentions. (.doc becomes .docx, power point becomes .pptx) I have manually changed it t

  • Does Redo Log include CLOB Columns Blocks?

    Hi All, Please help me in understanding how oracle handle redo logs on ENABLE IN ROW STORAGE CLOB's. How redo log behave on table with DISABLE IN ROW STORAGE ? for following table if I update column other than D_CLOB does Redo log stores the D_CLOB c

  • How do I export with clipping mask?

    I'm a newbie to Illustrator. I have a starburst design with a clipping mask. When I try to export as png or jpg, there is a transparent or white border around my design - where the items clipped by the clipping mask are hidden. I have flattened the f