Hi
I have a new  ME3400 series switch with IOS (me340x-metrobase-mz.122-37.SE1), it has 24 fastethernet and 2 gig fiber uplinks
Now all the ports except fiber uplinks are uni ports by default.
So can't communicate with each other. Now i wishes to make them communicate while remaining in uni port-type.
On forums the solution is to declare them as member of community vlan.
My questions are
1) can i no shut the secondry vlan interface?
2) From which pool i have to give ip to my system either from primary vlan pool or secondry vlan pool?
3) In both cases i can't communicate with the default gateway i.e: the ip of vlan even the port is member of community vlan. so how to communicate them while being in uni ports?
The sh run of switch is below
Switch#sh run
Building configuration...
Current configuration : 2088 bytes
version 12.2
no service pad
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
hostname Switch
no aaa new-model
system mtu routing 1500
ip subnet-zero
no file verify auto
spanning-tree mode rapid-pvst
spanning-tree extend system-id
vlan internal allocation policy ascending
vlan 100
  private-vlan primary
  private-vlan association 101-102
vlan 101
  private-vlan isolated
vlan 102
  private-vlan community
interface FastEthernet0/1
switchport private-vlan host-association 100 101
switchport mode private-vlan host
interface FastEthernet0/2
switchport access vlan 102
switchport private-vlan host-association 100 102
switchport mode private-vlan host
interface FastEthernet0/3
switchport private-vlan host-association 100 102
switchport mode private-vlan host
interface FastEthernet0/4
shutdown
interface FastEthernet0/5
interface FastEthernet0/6
shutdown
interface FastEthernet0/7
shutdown
interface FastEthernet0/8
shutdown
interface FastEthernet0/9
shutdown
interface FastEthernet0/10
shutdown
interface FastEthernet0/11
shutdown
interface FastEthernet0/12
shutdown
interface FastEthernet0/13
shutdown
interface FastEthernet0/14
shutdown
interface FastEthernet0/15
shutdown
interface FastEthernet0/16
shutdown
interface FastEthernet0/17
shutdown
interface FastEthernet0/18
shutdown
interface FastEthernet0/19
shutdown
interface FastEthernet0/20
shutdown
interface FastEthernet0/21
shutdown
interface FastEthernet0/22
shutdown
interface FastEthernet0/23
shutdown
interface FastEthernet0/24
shutdown
interface GigabitEthernet0/1
port-type nni
interface GigabitEthernet0/2
port-type nni
interface Vlan1
ip address 192.168.0.1 255.255.255.0
no ip route-cache
interface Vlan100
ip address 10.10.100.1 255.255.255.0
no ip route-cache
interface Vlan101
no ip address
no ip route-cache
shutdown
interface Vlan102
no ip address
no ip route-cache
shutdown
no ip http server
control-plane
line con 0
line vty 5 15
end
Any help will be apritiated and thanks in advance

njb7ty wrote:
Create two separate connection pools. Each one has its own url/userID/password to its own database. Example: If both are Oracle databases, you need the JDBC driver jar file in your classpath. You'll have to research how to create a connection pool.That is a pretty specific answer. Certainly inappropriate, for example, if the OP is attempting to just move records. Or compare records.
Probably ony useful if the OP wants to present to a client data from two databases. But since the OP said "communicate" that seems unlikely.

Similar Messages

  • A problem that how to communicate between PLC S7-300 and IA Server

    The PC running the OPC server is connected to PLC S7-300 via the RS232 serial port and the Siemens RS232-MPI adapter (product no. 6ES7972-0CA23-0XA0).
    But I encounter such problem when I create an object(S7_HMI)in IA Server:
    Step 1:
    links:http://www.simwe.com/forum/upload/2005/04/30/87472755.jpg
    Error message:
    Protocol error:Unexpected response from PLC
    links:http://www.simwe.com/forum/upload/2005/04/30/48471774.jpg
    When I communicate between S7-300 and PC by LOOKOUT 5.1,it works well.
    Could someone give me help? Thanks a lot.帖子被qzxin在05-08-2005 04:54 AM时编辑过了
    帖子被qzxin在05-08-2005 04:56 AM时编辑过了

    First of all, Thank You very much for Your answer.
    I'm using the TS Adapter that make the conversion from MPI to the serial bus.
    I have made yet control panels to supervisor systems with Omron PLCs and I correctly use the DataSocket with the DSC module: with Omron PLCs I've never had any problems of communications. The problems is now with Siemens. For the communication between control panel and PLC I have to use the internal modem of my computer and the OPC is S7_MPI of IA opc Server.I wondering if this OPC is ok for modem communications (inside there is a form to insert the phone number of the remote station) or if every kind of modem are compatible with S7-300 modem it has inside.I've noted that my computer modem don't do the phone number when i run the front panel!In running mode, if I take a look to the Block Diagram and I click the "Highlight Execution" button I don't see any animation on the code generated by the HMI Wizard to connect the only one tag to the DataSocket URL.
    Have You any other suggestions to solve the problem?
    Massimo Lazari

  • Assistance in How to Communicate to Serial Port

    Hello, I am designing an Interface to communicate with RFID Device. My problem is that I cannot seem to get the data sent to loop back and be displayed back to a textbox that I have setup. The serial port pins 2 and 3 have been connected with jumper
    wire so as to allow the data to transmit and return back. I have followed the example from an online source called "Simple Serial". Yet, everything seems to work except for the data return (received). Any assistance on the matter would be greatly
    appreciated. My apologies, I neglected to mention that I am using C# 5.0 in Visual Studio 2013 Ultimate.

    Hi,
    Your issue is out of support range of VS General Question forum which mainly discusses the usage issue of Visual Studio IDE such as
    WPF & SL designer, Visual Studio Guidance Automation Toolkit, Developer Documentation and Help System
    and Visual Studio Editor.
    Because your issue is about Serial Port, you can consult on ,Net Compact Framework forum like this thread:
    https://social.msdn.microsoft.com/Forums/en-US/59db36ee-88dc-436a-9222-bb0b7f9acbeb/serial-port-communication-using-cnet?forum=netfxcompact for better support.
    Thanks,
    We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
    Click
    HERE to participate the survey.

  • How to communicate over rs485 port?

    Hi!
       I'm wandering about how to make my cFP2020 module communicate over serial RS485.
      A simple scheme for the first part of my application is shown in
    the attached file.  If I launch MAX, should I see the fp 301 and
    401 modules as dependant of cFP 2020???
       Moreover, has someone examples regarding this app?  Thanks!!!
    graziano
    Attachments:
    network.pdf ‏22 KB

    Graziano,
    the answer to your question is found on this Knowledge base Article
    Connecting cFP-20xx to a FP-100x
    The only solution you have is to use optomux commands to communicate form the cFP-20xx over to a FP-100x device.
    In order to provide you the best support we can, we suggest you get in touch with us by phone by calling NI Italy Tech Support at
    +39.02.41.30.92.17
    Regards,
    AlessioD
    NI Italy

  • How to communicate between two servlet applications.

    I want to write a program that the system manager can see who is connecting the server.
    the system manager login the server via the browser with applet.
    the applet communicate with servlet .and the servlet work in the server get the customer message such as username ,Ip address etc from other servlet.
    how to realize it .?
    can you give some advice .
    I appreciate you .
    thank you

    Look at, http://forum.java.sun.com/thread.jsp?forum=54&thread=262144

  • How to Communicate between servers and Overwrite the file

    Hi,
    I have this application where in a config file is modified as per the data entered by the user through some jsps.
    Also, this application is also loaded on other server which may act as backup when the primary goes down.
    Now,my issue is:
    As soon as the file is modified i want to overwrite all the backup files on other backup servers, so that sync is maintained between all the files on all servers.
    i guess the communication between primary & backup servers could be done using RMI.
    I have gone through RMI tutorial & few examples on RMI but i'm not very clear where exactly the interface,impl and client program goes.
    i mean how does this actually work in a real time.
    Please could anybody shed some light on this.I would really appreciate.
    Thanks!

    Hi all can some one please give a solution ...Any suggestions would be greatly appreciated

  • How to communicate between applications

    Is it possible to have one java application cause another java applicalion to go into/out of a sleep or wait state. Both application are on the same machine.
    What I am trying to do is have a program which will wait/sleep (using little on no processing power)
    untill a database trigger(oracle) or another java program wakes it up.
    Regards
    Sam

    A simple way will be to use communication through sockets. The sleeping aplication will listen to a specific port and when it receives a signal will "wake up".

  • Thread Application - how to communicate between Threads

    I have an array of Threads which will be ran. Each thread is going to be running a child process (Runtime.getRuntime().exec). Certain processes have to be complete before others.
    For instance,
    A relies on no previous steps
    B relies on A
    C relies on both A and B
    D relies on only B
    etc...
    There are about 25 of these and possibly more in the future.
    Is there a way if I have an array to say the thread #1 is done, notify thread #3?

    First of all, you don't need to start a new
    Thread to start other processes asynchronously.
    Runtime.exec() doesn't block for the process to
    finish -- you can use the returned Process object and
    invoke methods on it to wait for it to finish or to
    see if it has finished.
    So unless these threads you're creating are doing
    some other stuff concurrently as well as running new
    processes (which already run in their own threads
    because they are new processes), you're
    over-engineering it.I do not understand what you mean by "you can use the returned Process object and invoke methods on it to wait for it to finish or to
    see if it has finished."
    Can you please elaborate?
    Also, this program will read any one of about 10 configuration files containing these steps and must figure out automatically how to manage them. I can't hard-code for this one Process or Thread to do this and another to do this.
    Also, the Thread is going to do more than just running the runtime.exec thing, it has to write to some files as well.

  • How to communicate between threads?

    When I create six clients, the server create six threads to match them. Five of the clients are connected to the server and one of them is waiting for connection. Later, I quit the client 4. The client 6 should be replaced the client 4 for connection. However, in the server side, how does the thread 4 send the message to tell thread 6 to replace its position when the client 4 quits? Any hints? Thanks!

    Yes I use linkedlist to store the threads. Every time a new thread is created, I assign a number to them such as client 1 assign 1, client 2 assign 2...... My server allows only five clients to connect to it. The extra clients need to wait until one of the client quits. However, I don't know how to replace the client 4 by client 6. Because all the clients are assigned a number. They can't change the number. For example, even if the client 4 is removed and the linkedlist remains 5 elements, the number of the client 6 is still 6. It does not change to 4. That means it still wait for connection. It never ever connect to the server. How can I solve this problem?
      public void runServer() {
        try {
          while (true) {
            // Step 2: Wait for a connection.
            threads = new ServerThread(this, server.accept());
            clientList.add(threads);
            client = (ServerThread) clientList.getLast();
            client.start();
        catch (EOFException eof) {
          System.out.println("Client is disconnected");
        catch (IOException err) {
          err.printStackTrace();
      }

  • Please help!! How to communicate between applet and pop up dialog box

    Hi friend,
    I have done a AWT pop up dialog box from Applet. In this pop up dialog box, I want get user name, and display on an Applet, anyone can tell me how to do? Thanks a lot!!!!
    Alva

    You need to create two methods in your applet, getName and setName as well as a name field.
    private name = "";
    public void setName(String n)
        name = n;
    public void getName()
        return name;
    }The various constructor methods for Dialog already take the owner of the Dialog (your applet) as a parameter, so in your applet's ActionEvent handler, all you have to do is call
        name = textName.getText().trim();
        owner.setName(name);Yes, it's that easy.

  • How to communicate between Flex and JSP and show the result in an Iframe

    Hi all
    I am trying to send some data from flex to one HTTPService and trying to show the same response jsp in an Iframe. But unfortunately i am unable to get the responce Jsp's url to set as a source for iframe.
    let me explain you clearly...I have a mxml where i am having a text box and a button in the left panel and in the right panel i am having an Iframe to display jsp. So once user enters some value in the text box and clicks button then HTTPservice's send method will be called with text box's content as an arguement. So i can fetch that value from request object in jsp and display the value in jsp. So the problem here is i want display that result jsp in my Iframe. I know that , we need that result jsp URL to display in Iframe . But as i am sending POST request to HTTPservice, i am not able to get the result jsp's URL in flex side.
    So i need help desperately from great minds.So anyone of you can give me some suggestions!!!!
    Regards

    Hi all can some one please give a solution ...Any suggestions would be greatly appreciated

  • How to communicate between JSPs?

    I have three JSPs say Test1.jsp, Test2.jsp and Test3.jsp. Test1.jsp does something and includes the control to Test2.jsp (jsp:include). Test2.jsp does something else and forwards Test3.jsp (jsp:forward). Now Test3.jsp wants forward back to Test1.jsp to the place from where it left not execute from start to bottom.
    Is it possible?
    Thanks in advance
    Thara

    Unfortunately, the way the processing is being done, what you are asking for is not possible. Once a request is forwarded to another resource, the current resource loses focus and control. Next time it tries to run, it will run from start to finish.
    In your scenario, why not include Test3 in Test2, which is itself included in Test1. This way, the following will happen:
    Test1.jsp
    Test1 start
    include Test2
    //once Test2 is done, it will return and continue from the next line
    more test1 code
    Test1 end
    Test2.jsp
    Test2 start
    include Test3
    //once Test3 is done, it will return and continue from the next line
    //since the next line is the end of Test2, no further processing
    //will be done and control will return to Test1 @ "more test1 code"
    Test2 end

  • How to Differntiate between two instances of the same class ????

    I don't even know if my question makes sense or not ??
    I don't have any code written for it yet.. but its the most critical task for me..
    Q ??
    say i have multiple objects running of the same class on the same box.
    sth like a CPU can have multiple ports. The port class is intantiated
    to create every new port for CPU as required.
    Now i have to differntiate multiple ports on that box and give
    accordingly its statistics back to CPU. sth like how many acces to
    ports, how much bandwidth available, how many bits.. i know how to
    calculate statistics of ports but i don't know how to differentiate
    between multiple ports ??
    Eg: Number of sessions created on oneport is 14 and other is 25. Then i
    have to give differnt statistics of these 2 ports back to CPU.
    I hope all this made some sense ???
    Thank youuuuu....reply back if u need some more details....
    Edited by: javanewbie83 on Jun 16, 2008 4:28 PM

    javanewbie83 wrote:
    I don't even know if my question makes sense or not ??
    I don't have any code written for it yet.. but its the most critical task for me..
    Q ??
    say i have multiple objects running of the same class on the same box.
    For an example: (its just a correlation to my project.. its actually not CPU and port numbers.. sorry if u misunderstand...)
    sth like a CPU can have multiple ports. The port class is intantiated
    to create every new port for CPU as required.
    Now i have to differntiate multiple ports on that box and give
    accordingly its statistics back to CPU. sth like how many acces to
    ports, how much bandwidth available, how many bits.. i know how to
    calculate statistics of ports but i don't know how to differentiate
    between multiple ports ??
    Eg: Number of sessions created on oneport is 14 and other is 25. Then i
    have to give differnt statistics of these 2 ports back to CPU.
    I hope all this made some sense ???
    Thank youuuuu....reply back if u need some more details....Simply repeating your unclear original post does not magically make it clear.

  • Can't communicate between JS and ExtendScript

    I tried this: (according to the docs it should work)
    In JS
    var csInterface = new CSInterface();
    csInterface.evalScript('$.test()', function(r){console.log(r)})
    In JSX
    $.test = function() {
                       alert("test");
                        return 65656;
    I'm seeing the alert, but the logged statement is empty. Anyone know how to communicate between the two?

    I tried a few ways but the only way I could do it properly was pretty involved:
    1) Use Socket.io to communicate between generator and extension
    2) When you want to raise an "event" from JSX, update generator settings, use a unique id for your event
    3) Parse the event in generator
    4) Emit the event from generator to extension.

  • How Vlan identifies from which port the data has come ?

    Hi ,
    We know that more number of ports can be configured to same vlan. How vlan distinguish between the ports ? How vlan knows from which port this frame has come ? in tagging we add the vlan id to the frame and not any other info ? little confused on how this haapens ??

    Disclaimer
    The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
    Liability Disclaimer
    In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
    Posting
    A VLAN doesn't really distinguish between ports.  A switch does, though, "remember" (for some time) the source MAC as frames enter its ports.
    Tagged frames may contain more than VLAN ID, such as L2 CoS.