How to Coordinate system in vision builder?

Hello,
I'm trying to perform a pattern matching in 8bit images but my image is not always in the same place so I need to stablish coordinates to analize the image, I'm using vision builder 6.1, does anybody have an example of how to stablish coordinates in vision builder?
Thanks in advance,
Ray

Ray-
Unforutunately, Vision Builder does not support coordinate systems. To do Coodinate systems, you will eiter need to port the code to LabVIEW and use the Vision Toolkit, or else upgrade to Vision Builder for Automated Inspection.

Similar Messages

  • How to Add Module to Vision Builder 2.0 using C++ or MathLab

    Hi, I am newbie with the NI product and this is the first time that I am using NI..I am now currently using NI Vision Builder AI 2.0 and just wandering if I can insert another module to the program..
    I am using C++,VB.Net 2003, and MATHLab..So, Is there anyway that I can actually write my own code and modify the program?
    Thanks guys!

    I recommend that you post this question to the Machine Vision forum. That forum is monitored by experts in Vision Builder. This forum is monitored by Measurement Studio experts. Unfortunately, we don't yet have direct integration between Measurement Studio and Vision Builder.

  • How to add coordinate system SVY21(SRID: 3414) to Oracle Spatial 11g/12c

    Can any one please help me for "How to add coordinate system SVY21(SRID: 3414, for Singapore) to Oracle Spatial 11g/12c'?

    Why don't you start with the documentation: Coordinate Systems (Spatial Reference Systems)
    Especially paragraph 6.9 (6.9 Creating a User-Defined Coordinate Reference System ) should be helpful for you.
    HTH,
    Stefan

  • How to use the examples in IMAQ Vision Builder?

    I tried many times to use the examples brought in IMAQ Vision Builder(or LabView 6i ?) or download the similar examples from website of NI in order to learn some skills(I am really new with it!). But Whenever I click the example I want to run and a new dialog window always opened and ask me to find a VI named ???(??? is like for emample: IMAQ Windraw) and I always failed to find this VI!!! Where are this VI or How to use those emamples??? Thank you advanced!!!
    Swedlin
    [email protected]

    Hello Swedlin,
    IMAQ WindDraw is a VI that is included in the IMAQ Vision toolkit (see http://sine.ni.com/apps/we/nioc.vp?lang=US&pc=mn&cid=1305 for ordering information).
    If you are tring to run examples that include IMAQ WindDraw (or any other functions that are in IMAQ Vision), a dialog message will prompt you locate the VI manually (because the initial search failed).
    - Installing IMAQ Vision for LabVIEW will remove the message, and the examples will run.

  • How can I see the current script file name in Vision Builder

    I would like to not have to remember which script file I have open. Is that displayed somewhere?

    Brian,
    I have been looking over Vision Builder 6.1, and from what I can tell, the name of the file that you are working on is not displayed on the screen, and there does not appear to be a way to get it to display there.
    This seems like a very worthwhile feature to add, and I definitely agree that it would be useful. You may want to consider filing a Product Suggestion by using the Product Suggestion Center (PSC) that is linked below:
    Product Suggestion Center
    The PSC links directly into our R&D group's suggestion database, and any suggestions entered would be reviewed by the R&D team.
    Regards,
    Jed R.
    Applications Engineer
    National Instruments

  • How can I get the coordinate in the layer coordinate system while doing the iterate?

    I found that the position(x,y) the iterate function tell me is not right sometimes.
    Actually,it happens when the top of the layer is negative. The "y"is in the comp coordinate system(maybe?) but not the layer.In another word, the position with y=0 is not the top.
    More specifically, I have got the color map of a layer. I am able to get the color of any pixel in the layer. But I can't set the color one for one when I use "iterate",because there is an offset.
    Am I supposed to get the offset? Is there any way to access the whole layer directly if I use iterate function?

    so indeed it's the offset at play.
    AE will diminish the buffer at 20% increments, and not for each pixel that
    goes out of sight. it's not really in relation to the upper left corner,
    it's all about what part of your layer buffer is out of sight.
    there's also an "iterate offset function". check it out. perhaps it will
    save you some trouble.
    On Fri, Dec 19, 2014 at 2:45 PM, Hinanawi Tenshi <[email protected]>

  • How do I copy images to buffer in Vision Builder Eval

    I have an evaluation copy of Vision Builder.
    I want to load images from files and do an image divide, yet when I copy images to the buffers, the buffers remain empty. Help!

    It sounds like you're using the Vision Builder AI eval and launching the Image Assistant tool to process your image. Buffers in the Image Assistant don't carry over to other steps. However, in one session of Image Assistant you should be able to save an image to a buffer and retrieve it in the same session. If this is not the case, then you should go to ni.com/ask to get in touch with an NI Applications Engineer.
    Kyle V

  • How can I use FlexMotion vector move function for cartesian coordinate system to other coordinate.

    I have problem with convesion from cartesian coordinate system to other one. I need use standard move function for example blend to moving 2 arms manipulator. What i need to do?

    The vector move will probably not give the results you are looking for. The vector move calculates the trajectory based on unit vectors in cartesian space. For a 2 arm robot (ex. 2 rotation joints), you would be able to move from point A to point B as desired, however the path would not be a straight line. The path may also not be suitable for the mechanism, which could cause a collision or maybe a singularity.
    The best solution is probably the contour move. You can use the inverse kinematic routine you wrote and send the results to a contour move. Contour moves are a little more complicated to use than the simple one axis or vector moves, however they are also much more flexible. I do not know of any functions already written for your system,
    but it sounds like you are already on the right path.
    Regards,
    Brent Runnels
    Applications Engineer
    National Instruments

  • How to integrate NI Vision Builder and Lab view 8.0

    Hi to all.,
        I want to integrate NI vision builder and Labview.... Please give me the idea and procedures to be followed........

    Hello Tec-sol,
    Are you using the Vision Builder for Automated Inspection? If you are, then you can create LabVIEW code. In the configuration interface go to Tools>>Migrate Inspection to LabVIEW. To do this you will need to have the Vision Development module installed.
    Or are you using the Vision Builder? Depending on the version of the vision builder you are using you can also generate LabVIEW code.
    If you want your code to run in LabVIEW I would suggest that you create your code with the Vision Assistant (this has replaced the Vision Builder, and ships with the Vision Development Module). The Vision Builder for Automated Inspection is intended to be a standalone application.
    Regards,
    Jasper S

  • Vision builder

    Hi there !
    I'm new in the field of machine vision and I need your help in my project,I want to build an application that inspects the sealed terminals of automative wires like in the image attaches below, calibration and edge detection and comparing the images in the real time to a standard image ,
    I want to know if that is possible ,and if it is how can I do so ?
    THANK YOU !
    Solved!
    Go to Solution.
    Attachments:
    aaaa.JPG ‏19 KB

    Hi layal,
    You are certainly on the right track with using the Vision Builder for Automated Inspection (VBAI). For an extensive outline of all the functions available to you, take a look at the VBAI manual here. First, you would typically want to define a reference coordinate system unless you can guarantee that the part will be located in the same position and orientation in the images. This is discussed on page 2-7 of the manual. Then, you could certainly compare the image, or certain portions in a specified region of interest (ROI) of the image to a template and detect the differences, check for gaps and part widths, locate edges relative to the coordinate system, etc. All the features are outlined in the manual in the context of some examples. I highly suggest that you take a look through the manual and also consider evaluating the VBAI software for 30 days if you do not have it already. You can access the download for the evaluation from the 1st link I posted. If you have more specific questions on the inspection, or how to carry it out, please provide more details concerning the pass/fail conditions for your part.
    Also, please bear in mind that if you run VBAI on a regular PC running an OS such as windows, the performance will not truly be real-time. To achieve deterministic performance, you would have to deploy this inspection to a real-time target such as the NI EVS, Smart Camera or a PC running LabVIEW Real-Time as the OS. Hope this helps!

  • I can not create an Installer, After install the Vision Builder Demo and then uninstall it. I can not create a Labview installer anymore, it asks me for a Vision Builder Installer, even if My Labview program does not have nothing to do with it...

    I can not create an Installer on LabView, After install the Vision Builder Demo and then uninstall it. I can not create a Labview installer anymore, it asks me for a Vision Builder Installer, even if My Labview program does not have nothing to do with it...
    Solved!
    Go to Solution.

     Hi Shada this can happen if you are including additional installers to your installer for example DAQmx. When you are doing this the installer has to include other files like MAX (Measuremente and Automation Explorer). Probably when you installed Vision Builder it updated MAX, so when your installer is trying to Include MAX, its asking for the source where it was installed in your computer in this case Vision Builder.
     Here you can cache the information so its not asked again, or you can download a newer version fo DAQmx, so it will update MAX and change de dependecy.
     You can find more details about this issue in this KB:
    KnowledgeBase 3S88PJMY: Why Do I Get A "Missing Distribution" Error When Trying to Build an Installe...
    And for keeping a copy here is more info:
     How Do I Stop the Missing Distribution Notification Each Time I Build An Installer?
    Best Regards
    Benjamin C
    Senior Systems Engineer // CLA // CLED // CTD

  • NI-1744 Smart Cameras go offline using Vision Builder AI and LV2010?

    I've run into a perplexing and frustrating problem.
    I have a set of 6 NI-1744 smart cameras used to monitor sample motion in an automated system
    A central robot moves samples between 6 satellite chambers; there is a camera mounted above the entrance to each of the satellites; the sample carriers are drilled with up to 10 holes encoding their numbers in binary (0-1023). There is also an L-shaped registration mark drilled near the region for the number encoding. Matters are complicated somewhat in that the second generation of carriers has a slightly more complicated registration mark (which includes the simple L of the first generation).
    What I would like to accomplish is this:
    Most of the time, I just want to be able to see what's under each camera, illuminating from above using a ring light attached to the camera. Call that Inspection A.
    I may need to capture an image without the ring light. Call that Inspection B
    When a sample transfer is occurring, I need to run a more complicated inspection (Inspection C):
    A light is turned on underneath the end of the sample transfer arm (the "fork"), backlighting the region where the hole pattern would be if a carrier is in fact present.
    Acquire an image of the fork with the backlight on.
    Check to see if the image shows the fork to be empty. If so, return that information and the inspection is complete.
    If not, look for the (backlit) registration mark and establish a coordinate system for the holes. Look to see which holes are present, calculate the sample number, return the data and the inspection is complete
    If not, look for the 2nd gen registration mark. If it is found, establish the coordinates as in step 4, calculate the number, return the data and complete.
    If none of the registration patterns are found, turn on the ring light, capture an image and return it so the operator can intervene and enter the appropriate data.
    I have successfully built the inspection, and it appears to work in the Vision Builder configuration interface, or if run from the Vision Builder inspection interface. If I attempt to *use* the inspection, accessing it via the VBAI interface in Labview, one or more of the cameras will hang after one or more inspections and stops responding to LabVIEW. It will take multiple reboots to get it back on line and visible to either VB or Labview.
    Originally, I had thought to configure the camera to run inspections continously and select inspection A, B, or C based on a variable I could access using the Labview Shared Variable Engine.  Every time I tried that the camera in question would hang. My current sort-of-successful software uses the VBAI functions in LabVIEW to open Inspection A, B, or C on the camera, run that inspection a single time and return the results and inspection image. That still ends up with one or more cameras hanging, especially if I've added the case to handle the more complicated registration mark.
    I think I may be running out of memory in the camera. I have occasionally received an out of memory error message when running the inspection in debug (step) mode in the VB configuration interface, at which point the camera will disconnect from the VB interface. When I look at the system monitor tab for a camera in MAX, I can see that it is showing me 11.5M free/124M total memory, and 72.3Mfree/118M total disk space. If I understand those numbers, that means that less than 10% of the memory is free when the inspection starts!
    I'm only communicating with the cameras via the ethernet interface. Are there any software components I don't need to have installed on the 1744 (MAX lists about 12 different things installed!) in that case?
    Alternatively, it appears there are VBAI functions available that might let me acquire an image and then process it via a local copy of Vision Builder running on the host PC, rather than in the camera. Is that so, and if so, would it be faster than running the inspection in the camera?
    I've attached a zipfile with the inspection that appears to stall the camera, and samples of typical images captured of the empty fork and a sample holder.
    Kevin Roche
    Advisory Engineer/Scientist
    Spintronics and Magnetoelectronics group
    IBM Research Almaden
    Attachments:
    Carrier Read Problem.zip ‏657 KB

    The good news: thanks to some offline assistance from Brad, my cameras are no longer crashing.
    The bad news: my labview VI using VBAI functions still fails for one or more cameras after a while (typically >12 hours of monitoring). 
    It's very odd: the cameras are still visible online.
    I can ping them.
    I can connect to them via VBAI, run inspections that way (either in configuration mode or inspection mode), and disconnect successfully.
    My calling VI, however insists that it can't connect (usually with a -354700 error from VBAI Connect.vi, occasionally with a -354705).
    I am using shift registers in the monitor loop of the main VI so that I can pass the VBAI session reference for each camera back to the subvis that actually load and run the desired inspection once a connection has been made. After an indeterminate time, one or more of those appears to go bad, but if I attempt to reset and connect to the camera again (I did include a control to let me close and reconnect if necessary from the monitor loop), I still get the above errors.
    The only way to get them back online within LabVIEW this morning proved to be to stop the main VI and reset all the controls to default, reboot the cameras, and then restart the VI. At that point it was able to connect to all 6 again and has been running happily for over 8 hours.
    I set up the persistent sessions using the shift registers because I have observed in the past continually opening and closing resources like that can lead to memory problems. It also dramatically reduced my cycle time when all I want to do is get the latest images from the cameras to under 2 seconds.
    Any ideas? Is there some subtlety to disconnecting/reconnecting to the VB in the cameras via Labview that I'm missing?
    I am working on a slightly smarter version of the inspection that can be allowed to run continously in a camera and simply return the appropriate result when asked, rather than having to start and stop different inspections as I do now, but that is not ready for deployment yet. It's the symptom of running just fine for X hours and then losing one or more cameras that is baffling me right now.
    Kevin Roche
    Advisory Engineer/Scientist
    Spintronics and Magnetoelectronics group
    IBM Research Almaden

  • Use of "IVA Coordinate System Mmanager"?

    I do not understand how the vi "IVA Coordinate System Mmanager" is used. When I do create the LV-code from the NI Vision Assistant it gives me following fragment:
    Here the "reference System" input is set (the x-/y axis) automatically to the value 562.95 and 558.641 (see picture above). What indicates those values if I do pattern matching? And to which values I need to set it for any image where I do pattern matching? The output of this vi gives me a cluster with the origin and the measurement system. Even I set those two values to 0/0 it gives me the corect and new coordinate system of the found pattern but I'll get an NaN if I use the same function (pattern matching) twice in a row for a different image. In both cases NI Vision Assistant sets those two default values automatically.
    thanks..!

    I have attachted a script file. Here u can see that the coordinates for the reference system has been set to the values where the coordinate system is.
    Question: Why are this coordinates (87.45/221) already set? Does it matter if I set the values for the reference system to 0,0?
    best regards
    Attachments:
    test.vi ‏58 KB

  • Vision builder AI 2011 incompatib​le with Vis created by Labview 2011 ?

    Hi,
    I have some issues to drive some motor by a Vi created under Labview 2011 using an inspection built under vision builder AI 2011
    The step for running  a Labview Vi said me that it only support 2010 VIs or earlier ? How two NI softwares 2011 can be incompatible ?
    So I try to save under a old version but this vi is part of a huge LLB...Is it possible to save this LLB as a 2010 version without saving all subvis .ctl etc.. ? I am a little confused...
    Thank you for your help

    You should be able to save the top level VI for previous to LV 2010, and all VIs from that LLB will also be saved to a LV 2010 version LLB that can be used by VBAI. There is a restriction that any VIs from a toolkit that you have to pay for (i.e. Vision), even if they are in your LLB will not be saved for previous, but driver VIs (i.e. Motion, DAQ, NI-IMAQ) if they are in your LLB will be saved in the resulting LV 2010 LLB.
    I realize this isn't ideal and VBAI will be supporting LV 2011 or a future version later. Another option will be to use the VBAI API in LV 2011 to have VBAI do just the image processing portion of your control system and do Motion, or other functionality in LV environment and control VBAI from LV using the VBAI API (this allows you to load inspections, run them, get images, and results, etc.), which does support LV 2011.
    Hope this helps,
    Brad

  • Vision builder migrating to labview... Many VI

    Hi,
     I am using the latest version of labview and NI vision builder. By using the Vision builder am getting the X and Y coordinates of the object in that area. I need to export this to labview. I tried by going to "migrate to labview" . Then I created a new folder, then I gave the name. When I click OK. It creates many VI's. I need this in single VI. When I open the "main.VI" i could only see "pass, start" ; when i check the block diagram.I couldn't find the programe that i needed for it.
    Hope you have understood my question.
    Can you please help me.
    Thanks in Advance
    Solved!
    Go to Solution.

    Another option, which could be used in conjunction with the API solution Christophe mentioned is to make your X/Y values shared variables that you update in your VBAI inspection and then read in your LV code. Here's a tutorial on using shared variables to communicate results to LV from VBAI:
    http://digital.ni.com/public.nsf/allkb/D492139A746​F91A8862576E80051BBCE
    Here's a video of how to use the API that Christophe was mentioning:
    http://zone.ni.com/wv/app/doc/p/id/wv-2424
    Here's a video of using shared variables (demo shows using RT targets, but the same idea would work locally):
    http://zone.ni.com/wv/app/doc/p/id/wv-2423

Maybe you are looking for

  • How do I get my Macbook Pro to print with HP Officejet 7500a Wide Format printer

    My Macbook Pro (Retina Display) seems to have a problem to print with the HP Officejet 7500a - Wide Format printer - Is it the OS X 10.10.2 causing the problem. It works when connected to the USB cable - but wireless print is a problem.

  • Free Course Offered by Garritan

    For those interested in symphony orchestration, Garritan, the makers of Garritan Personal Orchestra just posted an excellent tutorial on creating orchestral peices as originally developed by "the man" himself, Nikolay Rimsky-Korsakov.

  • 8i and 9i differences

    Can someone please give me a link to the documents that tells me all the differences between 8i and 9i Thnx...

  • Account Balance Access

    Some of our users do not have access to view a BP's Account Balance.  How do we set this so they can see the Account Balance?  Do CRM users get access to this? Thanks, Mike

  • Migration Workbench for Oracle10G?

    I am currently working on a project to move data and applications from SQLServer2000 to Oracle10G. Does Oracle Migration Workbench 9.2.0.1.7 support Oracle10G? Thanks in advance. Dora