How to find my subVI in my labview project?

Hi, friends.
As the title, how to find all my subVIs used in one project? Because if I want to change the connector of a VI, I must find out all the VIs in my project, and replace them one by one. Is there any better way to do that? Could you give me some suggestions?
Thanks!
帖子被delphi-wx在 10-26-2008 04:57 AM
时编辑过了

Rather than searching, the easiest way to do this is to let the LabVIEW compiler do the work for you. Open the top-level VI(s). Then, open your subVI. Make the change to your connector pane. Bang. The top-level VI(s) will show a broken run arrow. Click on the browen run arrow, and it will tell you the list of broken VIs. The ones that have a red "x" mark at the beginning are the ones that directly use your VI. At that point you can open their block diagrams and select "Relink" to relink to your new connector pane.
Message Edited by smercurio_fc on 10-26-2008 10:18 AM

Similar Messages

  • How to find/add new libraries in LabVIEW

    I am very new with LabVIEW and I am using version 6.0. I am trying to follow the tutorials but I cannot find some of the mentioned libraries. For example, the signal generation library (1SIGGEN.LLB) is missing. I would appreciate if one could tell me how to find and add missing libraries. Thanks.

    I don't know if the specific library you mentioned is one of them, but many of those types of libraries are not included with the Basic Version of LV. That could be your problem. If you have the Full or Professional Development version, the libraries should have installed when you installed LV.
    Mike...
    Certified Professional Instructor
    Certified LabVIEW Architect
    LabVIEW Champion
    "... after all, He's not a tame lion..."
    Be thinking ahead and mark your dance card for NI Week 2015 now: TS 6139 - Object Oriented First Steps

  • How to find expected GPIB address in Labview program

    I have inherited some Labview test programs without documentation.
    How do I find the expected GPIB address in a program?
    I found this for VISA USB to GPIB in the program:  USBO::0x0957::0x0618
    which is 2107  and 2025 in decimal and I don't know what that means.
    Thanks for you help.

    hawkinb wrote:
    I have inherited some Labview test programs without documentation.
    How do I find the expected GPIB address in a program?
    I found this for VISA USB to GPIB in the program:  USBO::0x0957::0x0618
    which is 2107  and 2025 in decimal and I don't know what that means.
    Thanks for you help.
    PID VID of the usb-gpib device
    Jeff

  • How to find enhancement RSAP0001 user exit EXIT_SAPLRSAP_001 project CMOD

    Hi,
    I need to find in one system the project in cmod that contains the enhancement RSAP0001 with user exit EXIT_SAPLRSAP_001.
    How do I proceed?
    Thanks a lot

    Simon,
    Goto CMOD and enter * and select F4 so that you will get the list of packages. Most of the clients we have naming terminology with BW. Pick one of them and go for components there you can see the interface.
    Double click on that you will see four classes. Select any one of them and write your logic.
    If you provide what exactly your are trying to do enhancements, so that will provide better solutions.
    Thanks
    Ganesh reddy.

  • How to implement general error handler in labview projects

    Thanks,

    Hello,
    You may also find these links useful:
    Custom Error Handling In LabVIEW
    http://zone.ni.com/devzone/conceptd.nsf/webmain/de​4f036f22c4b9f286256fee0010b6fd
    LabVIEW Introduction Course - Six Hours (has a section on error handling)
    http://zone.ni.com/devzone/learningcenter.nsf/03f7​c60f17aad210862567a90054a26c/55974411828f779086256​...
    Hope this helps!
    Charlie S.
    Visit ni.com/gettingstarted for step-by-step help in setting up your system

  • How To Find out Time Spent on a project

    The reason I am asking this question is because I would like to know how long I spent on a project so I can record it for future reference.
    With Sony Vegas you could have the time spent actually showing in the software with some tweaking Iw as wondering if you could do the same in Final Cut Pro.
    Thanks for the help guys

    Not as far as I know.
    I find the program based trackers to be a waste of time. Does this happen to you? You go for a coffee break that turns into lunch that turns into a new project meeting and you left the project open the whole time? If so, whatever time the program says you've been working is hours off.
    Just keep a notebook on the desk to track hours if you like analog or set it up in iCal (or Quicken) and develop the discipline to keep your time.
    Nothing is as simple as making a note on a piece of paper - really.
    x

  • How do we use if statement in labview?moreover can i use if statement inside for loop?

    how do we use if statement in labview?moreover can i use if statement inside for loop?

    The if statement in LabVIEW is the Case structure. You can find that on the Structures palette right next to the For Loop. If you're still on the same subject about terminating a for loop early, then what you do is enclose your functions inside the loop with a case statment and make one of the case's empty except for one or more constants that you might have to wire. Hopefully, the attached picture will explain what I mean. Also, as I mentioned in one of your other posts, I think this technique is not as good as using a while loop. The array in the attached example is the same size no matter what and you may have to handle stripping extra or invalid elements.
    Attachments:
    For_Loop_with_Case.jpg ‏21 KB

  • "Open VI Reference" Option "Prompt user to find missing subVIs"

    I am using "Open VI Reference" to dynamically load a VI. For the "option" control of the "Open VI Reference" node, I pass "0x10" or "10" in hexadecimal, which supposedly "prompt user to find missing subVIs." Nevertheless, I don't get a prompt message dialog when I intentionally pass an invalid or missing VI path. Instead I just get an Error Code 7. What does this option "Prompt user..." suppose to do?

    Make sure you set the properties on the integer input into the “options” control to the “Open VI Reference” to be a Hexadecimal format (right-click on the “options” control input, select Format and Precision…, then select Hexadecimal). Now, if you re-run your VI and wire in a VI with a missing subVI, the Open VI Reference will appear with a dialog that will prompt you to browse to the missing subVI. This is exactly the same message LabVIEW displays when it attempts to open a VI and cannot find its subVIs.
    I’ve attached a simple example program to demonstrate. Enter the path to the “number extractor.vi” as the VI to open. You should see a dialog prompt appear asking for the “Search 1D Array – Complete.vi”.
    Hope this helps!
    Attachments:
    openVIRefExample.zip ‏20 KB

  • How to close open subvi's in the beginning of running the main vi.

    Hello,
    I've got a pretty large application that is dependant on several subvi's.
    I'm searching for a way to close the subvi's when I start running my main application.
    All these subvi's need to be closed during the initialisation phase of my main application. (before it is doing its main task.)
    I know it is possible to ask for the VI's in memory for my LabVIEW application, but I don't know how to close a subvi programmatically. (unload it from memory)
    What I want to do is check for a list of open subvi's in the beginning of my main application. (only a limited set of subvi's)
    If one of the subvi's is indeed open I want to close it (unload it) and then start doing my thing from within the main application.
    Note: The subvi's need to be closed so that I can load them dynamically later in the program. If one of the subvi's is open and I start running my main application I get an incorrect behaviour.
    Thx for the help!
    Message Edited by noxus on 11-14-2006 08:07 AM

    Noxus,
    I programmed a small example.
    If you have further questions do not hesitate to come back...
    BR,
    ThSa
    (Additonally I added the screenshot in term of that you do not have LV 8.20)
    http://www.newgistics.com
    Attachments:
    VI_Server_LV820.zip ‏12 KB

  • How to find the nearlest value in 1-D array ?

    Hi.. everybody..
    I need to seperate the raw data(1-D) into 2 group of array by the center value and then make the average value in each array. But I also still have the problem about if the center value is not the same of some value in the 1-D array. I cannot use the split function.
    "How to find the nearlest value to the center point that I calculated, in the 1-D array ?"
    Thanks a lot for anybody help

    In a general sense, since I'm not sure what your data values are or how far away your calculated center is from the true value, I would do it one of two ways:
    1) Use a threshold value and scan the array until the threshold is reached (assumes constantly increasing values in the array).
    2) Use either a) round to nearest integer b) round to + Infinity (round up) or c) round to - infinity (round down). If you don't have decimal values, you'll have to devide the values by a power of 10.
    2006 Ultimate LabVIEW G-eek.

  • Can someone tell me how to emulate serial terminal window in labview??

    Hi can someone tell me how to emulate serial terminal window in labview?  or provide me simple code to do it? 
    baud rate 9600

    Have you tried looking through the example finder?  There's a a few great examples in there on how to read from and write to a serial port.  In LabVIEW just choose Help > Find Examples... and then navigate to Hardware Input and Output > Serial > Basic Serial Write and Read.vi
    David_L | Certified LabVIEW Architect
    LabVIEW Tools Network | LabVIEW Tools Network Developer Center

  • K mean:: how to find the clustred data;:: or how to assign number t0 each group of data

    hi member
    i have download the LabVIEW Machine Learning Toolkit https://decibel.ni.com/content/docs/DOC-19328
    i want to excute the K mean algorithem to cluster the image in two group or three or more
    the problem is how to find the result i mean the clustred image', the image that contain 2 or three intesity value only
    or how to aasign a 1 vlaue to all intesity that 
    belong to cluster one and 255 to data that belong to cluster 2
    so that the image look like binary image???
    a my vi below
    best regards
    Solved!
    Go to Solution.
    Attachments:
    k mean.vi ‏12 KB

    my post before showed how to set the threshold manually using the graph's cursor.
    here's the automated k-means version, using the toolkit's .vi
    Alex
    ♜♖ LabView 8.6 - LabView 2014 ♖♜
    Attachments:
    2013-06-22_2dhistogram 2009.zip ‏61 KB

  • How to execute Show Desktop.scf in Labview?

    Dear all,,
     Can anyone tell me how to excute Show Desktop.scf in labview?
    Regards,
    Santhosh
    Solved!
    Go to Solution.

    Hi Naveen,
    I was trying to find right command for this.
    CMD /C "C:\Documents and Settings\Username\Application Data\Microsoft\Internet Explorer\Quick Launch\Show Desktop.scf"
    This is string generated and given to command line input. (In your code)
    I did not write "/c"..I was trying with following string.
    CMD  "C:\Documents and Settings\Username\Application Data\Microsoft\Internet Explorer\Quick Launch\Show Desktop.scf"
    So close..this was something I enjoy..Try to do something new. Thanks for the solution.
    Gaurav k
    CLD Certified !!!!!
    Do not forget to Mark solution and to give Kudo if problem is solved.

  • Error: Unable to find all subVIs from saved VIs.

    TestStand 2010 SP1, LabVIEW 2011, WinXP
    Trying to build a deployment in TestStand.
    During the build, I get the now-infamous popup:
    Title: "Save Modified VIs?"
    Text: "An error occured while trying to read the dependencies of your VIs; a possible cause for this problem is VIs not saved in the current version of LabVIEW. Would you like to save any modified VIs now?"
    I select "yes", and the build then fails with errors in the log pane of the "Build Status" window.  The error is:
    Error: Unable to find all subVIs from saved VIs, either a subVI is missing or the VI is not saved under the current LabVIEW version.
    The missing file path is:  etc, etc.
    I go to said missing path.  The VI is in fact present.  I open the VI and do "Save All", try again.  Same thing.  Then, I try a Mass Compile on the test VI directory.  Attempt to build again, same error.
    Note that I do call some VIs dynamically, but those are all present in my workspace, and are not found in this error.
    Is there a debugging option or log file or some kind of trace I can do to dig into this and find out the state of things causing the error?  Please help me out here.
    -Andy

    One quick way to narrow down the issue is to change your LabVIEW adapter to Run-Time engine and then try and run the sequence in the Sequence Editor.
    Also, triple check your search directories and make sure you're not pulling in VIs from an unexpected location.
    When you see that dialog it's already too late to save so trying to Save at that point never works.
    Another tip is to ignore which VIs it says are not saved in the current version and instead look at the subVIs that those VIs are calling. You can run into this if you have two subVIs loaded with the same name.
    CTA, CLA, MTFBWY

  • How do I distribute an executable from Labview 8.6

    I have Labview 8.6, Professional Development version. I want to know when I create an EXE file and then want to run it from a computer that does NOT have Labview installed, what support files will I need? What directory will I find them in on the computer with Labview installed? And what directory will I need to put them in on the computer that does not have Labview on it?

    Ben321 wrote:
    How do I make an installer package? Do I have to make one with external software like InstallShield? Or does labview do this when you make the EXE file to start with? Or does labview have a separate feature to do this? Please explain?
    You create an installer in a similar way you create an application. It's all built into the LabVIEW project.
    Details
    LabVIEW Champion . Do more with less code and in less time .

Maybe you are looking for

  • Error while adding a job to scheduler

    Hello, I have a batch job that is running fine in both DEV and QA environment. In DEV, I am able to schedule and run it daily. I created a similar schedule in QA environment using BODS Mgmt Console/Administrator. However, upon Activating the schedule

  • Pass value of column when report has only one row

    Hello everyone, Sorry for not being very accurate with the title of the thread.Here's my situation: I have an item that, when modified(key pressed) refreshes an interactive report. All the report column have link to a javascript function, so when the

  • Objects transformation in abap  xmlns

    how I can know that the value of a variable xmlns? For example, the code then I need to know the value of P_PAIS <?sap.transform simple?> <?mso-application progid="Excel.Sheet"?> <tt:transform xmlns:tt="http://www.sap.com/transformation-templates">  

  • Problems with XMLType and namespace

    Dear subscribers: I have been using XMLType successfully with simple XMLs - without namespaces. Now I must handle messages with "xmlns" and it seems XMLType is failing. I tested the following XML, extracted from w3c.org examples: <?xml version="1.0"?

  • 1 to 1 Mapping using Indirection is causing a StackOverflowError exception

    I am trying to map a database column that contains a BLOB (i.e. PDF) to a persistent object's attribute that will contain the BLOB as a "1 to 1 mapping" utilizing "Indirection". The type of the persistent object's attribute is ValueHolderInterface an