How to stop the running process chain

How to stop the running process chains or infopackges...just qm status change is enought?

BI - SM 37 - Kill the Job
ECC - SM 50 - Kill the job

Similar Messages

  • How to stop the running infospoke

    Hi Experts,
    there is a infospoke is still running so long time, it's incorrect, i'll cancel it as kick off the dependenies, i have no idea to how to stop the running infospoke. Anybody could tell me how to do it. thanks in advance.

    hi denny,
       Go to SM37 , find the job , stop the process
    or
       To stop the job find the job with the help of the request name ( TC - SM37 ),then in the job Details find the PID .
    find the process in the process Overview (SM50 / SM51 ).
    Set the restart to NO and Cancel the process without core
    u can also see these threads that are already posted:
    stopping v3 run job LIS-BW-VB_APPLICATION_02_010
    how to cancel or change the background job which is scheduled
      In SM37, for the job , click on Step button. Then from the menu Goto > variant. You can see the process chain name here.
    sure it helps
    Thanks
    Varun CN

  • How to stop the backup process....

    How to stop the backup process....
    Okay, so it happens nearly everytime you synch your iPhone with your iTunes? Easy. As soon as it starts, hit the "X" in the bar where the backup process is being shown, this does NOT STOP the synching process, ONLY the backup process.
    HOWEVER, keep in mind that a few times during the week (depends how often you synch ur iPhone) it will be good to let the backup process let run fully.
    There we go. Problem solved...

    i agree its what i do i backup whenever i add a new app, or take more pics etc its exactly what i do its what ive been saying on all these threads talking about backups etc, im hoping in 2.0.1 will be bug fixes about this sort of thing...

  • How to continue the running process behind the model dialogue box options ?

    How to continue the running process behind the model dialogue box options like this
    In Updation of K7 user press the Cancel Button
    New dialogue box appear with Yes/No options.
    But the backend updation is going on... not Pause the updation.
    Like this how to do ?
    Please provide me code.

    I don't know, if you mean you have done your form or you have solved the problem.
    It's visible your code is only partly reflecting your screenshot, and that's okay to demonstrate the problem you have given a fine example.
    As you marked my suggestion as solution this may not be needed anymore, but here's how I modified your code and used a self made QuestionBox instead of messagebox.
    The essential part is defining a callback method and letting the QuestionBox call back there. It's not essential I used RAISEEVENT, but it's fine as it has all the behaviour and parameters needed to call back.
    Public oTestFrm
    oTestFrm=Createobject("MyForm_Model_to_NonModel")
    oTestFrm.Show
    Define Class MyForm_Model_to_NonModel As Form
    onxx = 0
    Add Object lbl_DispValue As Label With Top=90, Left = 120, Width = 50, Height=30, Caption=''
    Add Object cmd_Start As CommandButton With Top=120, Left = 120, Width = 50, Height=30, Caption='Start'
    Add Object cmd_Stop As CommandButton With Top=120, Left = 190, Width = 50, Height=30, Caption='Stop', Enabled =.F.
    Procedure cmd_Start.Click
    This.Enabled =.F.
    Thisform.cmd_Stop.Enabled =.T.
    Thisform.onxx = 0
    Do While Thisform.onxx < 90000000
    DoEvents
    Thisform.onxx = Thisform.onxx +1
    Thisform.lbl_DispValue.Caption = Transform(Thisform.onxx)
    Enddo
    This.Enabled =.T.
    Thisform.cmd_Stop.Enabled =.F.
    Thisform.lbl_DispValue.Caption = ''
    Procedure cmd_Stop.Click
    * Here, I want NO PAUSE -- (Show running numbers continuously...)
    * how to control Model to NonModel in Messagebox.
    QuestionBox('Really stop the process', Thisform, 'handleanswer')
    Endproc
    Procedure handleanswer
    Lparameters tlYes
    If tlYes && means Stop
    Thisform.onxx = 99999999999999999
    Endif
    Endproc
    Enddefine
    Procedure QuestionBox()
    Lparameters tcMessage, toCaller, tcCallback
    If Not Pemstatus(_Screen,"oForms",5)
    _Screen.AddObject("oForms","Collection")
    Endif
    oMsgBox = Createobject("QuestionBoxForm", tcMessage, toCaller, tcCallback)
    _Screen.oForms.Add(oMsgBox)
    oMsgBox.Show(2)
    Endproc
    Define Class QuestionBoxForm As Form
    Autocenter = .T.
    AlwaysonTop = .T.
    Minwidth = 200
    Add Object label1 As Label With AutoSize=.T., WordWrap =.T.
    Add Object cmdYes As CommandButton With Caption = "Yes", Width=40
    Add Object cmdNo As CommandButton With Caption = "No", Width=40
    Procedure Init()
    Lparameters tcQuestion, toCaller, tcCallback
    Thisform.label1.Caption = tcQuestion+" ?"
    This.AddProperty("oCaller",toCaller)
    This.AddProperty("cCallback",tcCallback)
    This.Width = Max(This.Minwidth, Thisform.label1.Width)
    Thisform.label1.Left = (This.Width-Thisform.label1.Width)/2
    This.Height = Thisform.label1.Height+48
    This.cmdYes.Left = This.Width/2 - 10 - This.cmdYes.Width
    This.cmdNo.Left = This.Width/2 + 10
    This.cmdYes.top = Thisform.label1.Height+24
    This.cmdNo.top = This.cmdYes.top
    Endproc
    Procedure cmdYes.Click
    #Define clYes .T.
    Raiseevent(Thisform.oCaller,Thisform.cCallback,clYes)
    Thisform.Release()
    Endproc
    Procedure cmdNo.Click
    #Define clNo .F.
    Raiseevent(Thisform.oCaller,Thisform.cCallback,clNo)
    Thisform.Release()
    Endproc
    Enddefine
    I didn't yet introduced a timer for counter display updates. As you see the counter hangs a bit, if you mouse over your form, but it is a way of multithreading without using a separate thread and instead keep the rest of the application active by DOEVENTS
    in the long running loop code.
    Bye, Olaf.
    Olaf Doschke - TMN Systemberatung GmbH http://www.tmn-systemberatung.de

  • How to check the parent process chain of a meta chain

    Hello Friends,
    Recently I joined a new project, which is of environment BW 3.0. I am trying to find the dependent process chain's parent, but could'nt able to find them. I went through all the process chains manually to check whther the dependent process chain is mentioned in them, but could'nt find any......
    Can any of you help me to know how to find the parent process chain of a meta chain ?
    I really appreciate your time, will be awarding points to any answers.......
    Thanks,

    Hello Radhan,
    thanks for your quick reply. I searched the table based on your advice, but i could'nt get the parent process chain's name. Can you throw some more ideas please..........
    Thanks,

  • PFRD 11.1.1.4 - How to stop the In-process Reports Server

    I'm running an "out-of-the-box" PFRD 11.1.1.4 installation in Windows XP SP3.
    According with documentation:
    http://docs.oracle.com/cd/E17904_01/bi.1111/b32121/pbr_strt006.htm#BEHDJFHD
    To directly start or stop the in-process Reports Server using a URL, enter the following in your Web browser:
    http://machine_name:port/reports/rwservlet/startserver
    http://machine_name:port/reports/rwservlet/stopserver
    startserver works.
    stopserver returns:
    REP-50171 : Authentication failed.
    Tried
    http://machine_name:port/reports/rwservlet/stopserver?authid=weblogic/passwd
    same error.
    Commented the line:
    <!--security class="oracle.reports.server.RWJAZNSecurity" id="rwJaznSec"/-->
    in rwserver.conf.
    Same error.
    The only uncomented elements in "rwservlet.properties" (original configuration) are
    <server>rep_wls_reports_pfurtado-lap_asinst_1</server>
    <singlesignon>no</singlesignon>
    <inprocess>yes</inprocess>
    Did any of you managed to stop "in-process" reports server using the reports servlet?
    What credentials did you use?
    Thanks & Best Regards
    Paulo

    Thanks RZ!
    The line you mentioned was already as you described.
    According with the documentation:
    [Starting and Stopping Reports Server|http://docs.oracle.com/cd/E17904_01/bi.1111/b32121/pbr_strt001.htm#i1005629]
    If Reports Server is running as an in-process server through the Reports Servlet, issue the following URL:
    http://your_host_name:port_number/reports/rwservlet/stopserver?authid=admin user/admin password
    Note:
    authid is Reports Server's administration user name and password. In Oracle Reports 11g Release 1 (11.1.1), the default security is based on standards-based Java EE security model through Oracle Platform Security Services. For a non-secure Reports Server, this user is defined in the identifier element.
    I added the identifier element to rwserver.conf and restarted WLS_REPORTS, but after this the in-process reports server failed to start with the usual generic exception.
    I finally found the missing step in:
    How To Secure Showjobs Web Command In A Non Secured Reports Server In Oracle Report 11g? (Doc ID 1242614.1)
    The thing is that the identifier element has to be placed in the right location inside rwserver.conf:
    The needed change is:
    FROM
    <queue maxQueueSize="1000"/>
    <pluginParam name="mailServer" value="%MAILSERVER_NAME%"/>
    TO
    <queue maxQueueSize="1000"/>
    <identifier encrypted="no">....type here your user/password....</identifier>
    <pluginParam name="mailServer" value="%MAILSERVER_NAME%"/>
    So although using the default non-secure reports server, the identifier element has to be present in rwserver.conf for rwservlet/stopserver to work as described above.
    Otherwise the needed authentication will fail as described.
    Regards
    Paulo

  • How to stop the upload process?

    Hi,
    i had by mistake started the other upload than the required!
    How to stop the current upload process,( generally it takes lot of time to upload the data as data is huge )
    Thanks,
    Ravi

    Hi Ravi Kottur 
    Just follow the things like Sunil suggested check one more just kill the process
    manually and goto RSMO and in the Monitor QM status just Amke it red manually
    for the load which you want to stop and then go to that particular info provider
    Manage and delte the request.. 
    Hope itz clear a little atleast...!
    Thanks & Regards
    R M K
    ***Assigning pointz is the only way of saying thanx in SDN ***
    **Learning the thingz is never end process if u stop it will Be a devil if u continue it will be a divine***
    > Hi,
    >
    > i had by mistake started the other upload than the
    > required!
    >
    > How to stop the current upload process,( generally it
    > takes lot of time to upload the data as data is huge
    > )
    >
    >
    > Thanks,
    > Ravi

  • How to activate the deleted Process chain

    Hello Experts,
    Unfortuantely we have deleted few process chain by in RSPC .But we are in need of this Process chain . Could you please let us know whether there is any possibilties to get back the deleted process chain .
    Please let us know where the deleted process chains are stored in the system.
    Many Thanks for your Help.
    Regards,
    Kumar

    Hi,
    you can restore it from a backup or in case the chain was transported from one of the target systems or the development system. No other way.
    regards
    Siggi

  • How to stop a triggered process chain

    Hi,
    Does anyone know how to stop a process chain? It was accidentally triggered twice and we need to stop it. Thanks.

    Hi,
    There r 2 ways to kill the job.
    One is using transation RSMO locate the job and display the status tab double click on the yellow light that is shown on the line total, a pop will come 'set overall status ' is displayed select the desired status that is red and save it. Then return to the monitor page and select the header tab double ckick on the data target right click and then goto 'manage',there should be request sitting there probably with yellow lights , highlight the line with the faulty request click the  delete button then click refresh button.
    Second is goto SM37 and click on the active selection and enter the jobname and then click excute the particulr job should appear highlight the jobname then click on the stop iconthat appears on the taskbar( 3 rd from left)
    hope it is clear.
    Regards-
    Siddhu

  • Increse No of BGP while data load and how to bypass the DTPin Process Chain

    Hello  All,
    We want to improve the performance of the loads. Currently we are loading the data from external Data Base though DB link. Just to mention we are on BI 7 system.  We are by passing the PSA to load the data quickest. Unfortunately we cannot use PSA.  Because loads times are more when we use PSA. So we are directly accessing views on external data base.  Also external data base is indexed as per our requirement.
    Currently our DTP is set to run on the 10 parallel processes (on DTP settings for batch Batch Manager with job class A). Even though we set to 10 we can see loads are running on 3 or 4 Back ground parallel processes only. Not sure why. Does any one know why it is behaving like that and how to increase them?
    If I want to split the load into three. (Diff DTPs with Different selections).  And all three will load the data into same info provider parallel. We have the routine in the selection that will look a table to get the respective selection conditions and all three DTPs will kick off parallel as part of the process chain.
    But in some cases we only get the data for two or oneDTPs(depends on the selection conditions). In this case is there any way in routine or process chain to say that if there is no selection for that DTP then ignore that DTP or set to success for that DTP and process chain should continue.
    Really appreciate your help.

    Hi
    Sounds like a nice problemu2026
    Here is a response to your questions:
    Before I start, I just want to mention that I do not understand how you are bypassing the PSA if you are using a DTP? Be that as it may, I will respond regardless.
    When looking at performance, you need to identify where your problem is.
    First, execute your view directly on the database. Ask the DBA if you do not have access. If possible perform a database explain on the view (this can also be done from within SAPu2026I think). This step is required to ensure that the view is not the cause of your performance problem. If it is, we need to implement steps to resolve that.
    If the view performs well, consider the following SAP BI ETL design changes:
    1. Are you loading deltas or full loads. When you have performance problems u2013 the first thing to consider is to make use of the delta queue (or changing the extraction to just send deltas to BI)
    2. Drop indexes before load and re-create them after the load 
    3. Make use of the BI 7.0 write optimized DSO. This allows for much faster loads.
    4. Check if you do ABAP lookups during the load. If you do, consider loading the DSO that you are selecting on in memory and change the lookup to refer to the table in memory rather. This will save tremendous time in terms of DB I/O
    5. This will have cost implications but the BI Accelerator will allow for much faster loads
    Good luck!

  • How to stop a running process

    If I have a class
    class MyTest{
    public void start(){
    int count=0;
    while(true)
    System.out.println(count);
    ++ count;
    class TestRun{
    public static void main(String[] args)
    MyTest test = new MyTest();
    test.start();
    My question is is there a programatic way to stop MyTest counting in TestRun ? except of course by assigning it a null value;

    First of all what you have is not a process -- it's a thread. Separate processes each have their own memory, but threads share the memory with the other threads in the process.
    Second, I don't see any reference that you could set to null to stop the thread. Were you thinking of setting your local reference to the thread to null? That will only set that particular reference to null, and will not affect the thread.
    You could call stop() on the thread to stop it, but doing so is unsafe.
    The best solution is for the thread to continually check some flag to determine if it should keep running. The loop should continue only while that flag is true.

  • How to check the scheduled process chain in SM37

    Hi Experts,
    Can anyone tell me how do I check whether my process chain has been scheduled or not.
    I checked in sm37 all the jobs that are under released status. Im getting about 10 jobs.
    I dont know which one is belogs to my process chain as they do not have the process chain names.
    Can anyone please let me know how do I confirm whether one of the released jobs below to my process chain.
    Thanks in advance.

    Hi,
    To find this out, in sm37, select the job and click on step button in toolbar. You would find the program name RSPROCESS.
    Click on this job and then go to menu bar and select goto-> variant.
    In the variant, you can see the process chain that has been used for this job.

  • How to stop the boot process after the GRUB menu?

    Hello there.
    I am getting an error message in the boot process, after the GRUB menu, but I can't read completely the message because it is shown too fast. So, how can I stop the process when I see the error message, for writing down it?
    Thanks in advance.

    zuargo wrote:
    Hello there.
    I am getting an error message in the boot process, after the GRUB menu, but I can't read completely the message because it is shown too fast. So, how can I stop the process when I see the error message, for writing down it?
    Thanks in advance.
    I didn't try this before, but if you use systemd, you may want to try systemd.confirm_spawn to invoke interactive booting process, so you can start the services one by one manually therefore locate the one throwing out error message.
    It is explained in the systemd manual:
    http://www.freedesktop.org/software/sys … stemd.html

  • How to invoke the running process via email or watch folder?

    Hi,
    I initial a process in workspace using a pdf form(xfaFrom type) variable.
    It's a simple process. Just one assign task node to transfer the initial form to process creater.
    The process works fine when submit in workspace.But I have some problem on offline submit.
    I initialed the form on workspace and saved it to local file to edit it.
    After editing the pdf form, how to let the local saved form go back to the process whith the correct data?
    Here is my variable setting in process:
    form type: xfaForm
    render service : render PDF form (in forms sample catagory)
    submit service : Submit PDF Form (in forms sample catagory)
    I've tried to use email endpoint.
    It will be back to the next step of the process, but the data will not be transfer to the form.
    Then I've tried to use watchFolder endpoint.
    And it did not work by some exceptions.
    Failure Time----Tue Mar 18 10:23:52 GMT+08:00 2008
    source location ---- Reason of failure is-----Cannot coerce object: <document state="active" senderVersion="3" persistent="false" senderPersistent="true" passivated="false" senderPassivated="true" deserialized="true" senderHostId="127.0.0.1/192.168.65.143" callbackId="0" senderCallbackId="0" callbackRef="null" isLocalizable="true" isTransactionBound="false" defaultDisposalTimeout="600" disposalTimeout="600" maxInlineSize="65536" defaultMaxInlineSize="65536" inlineSize="0" contentType="application/pdf" length="265731"><cacheId/><localBackendId/><globalBackendId/><senderLocalBackendId/><send erGlobalBackendId><DocumentFileID fileName="C:\Adobe\LiveCycle8\jboss\server\all\svcnative\DocumentStorage\docm120580620223 4\b680381b2f382c4aba702061e12876d6"/><senderGlobalBackendId/><inline/><senderPullServantJn diName>adobe/idp/DocumentPullServant/adobejb_server1</senderPullServantJndiName><attribute s file="C:\Adobe watch folder\offline\stage\Wxebcb14694b8ef1aee4b27261\off.pdf"/></document> of type: com.adobe.idp.Document to type: class com.adobe.idp.taskmanager.form.impl.binarycontent.BinaryContentFormInstance
    Cannot coerce object: <document state="active" senderVersion="3" persistent="false" senderPersistent="true" passivated="false" senderPassivated="true" deserialized="true" senderHostId="127.0.0.1/192.168.65.143" callbackId="0" senderCallbackId="0" callbackRef="null" isLocalizable="true" isTransactionBound="false" defaultDisposalTimeout="600" disposalTimeout="600" maxInlineSize="65536" defaultMaxInlineSize="65536" inlineSize="0" contentType="application/pdf" length="265731"><cacheId/><localBackendId/><globalBackendId/><senderLocalBackendId/><send erGlobalBackendId><DocumentFileID fileName="C:\Adobe\LiveCycle8\jboss\server\

    hi
    The problem is not completely solved.
    The solved part is countinue the process by Email and there is still need to be soloved by watch folder. Here are some steps.
    First, I set the email endpoint on "complete task" service(in process management catagory). Then configure the input parameter of the endpoint. The attachment parameter set to *.* and the mail from set to %SENDER%.
    Second, the xfa form variable of process must have process fields and use the default render. So the process field data which are required to counitnue the process will be keeped.
    Then it worked.
    But when I check the "complete task" component(process management --> task notification catagory) used in "complete task" process. Some input parameters(Sender, attachment map) are required and can't be found if using watch folder. So there is still a problem by using watch folder.
    Bking Chuang

  • An error ocurred while installing os x - how to stop the upgrade process?

    Hello:
    I tried a lot of ways, entered on safe mode and redownloaded the upgrade, booted on recovery mode to check the disk (no errors), restarted the upgrade several times, I erased /Library/Updates... all of these I did several times but no luck...
    How do I get it to stop trying to ugrade on reboot? the only way I can get into the old os is in safe mode, righ now i only want to get into the old os ... Any advise?

    Hello:
    I tried a lot of ways, entered on safe mode and redownloaded the upgrade, booted on recovery mode to check the disk (no errors), restarted the upgrade several times, I erased /Library/Updates... all of these I did several times but no luck...
    How do I get it to stop trying to ugrade on reboot? the only way I can get into the old os is in safe mode, righ now i only want to get into the old os ... Any advise?

Maybe you are looking for

  • 1st Gen iPod touch not charge and not recognized by iTunes

    I bought 1st gen iPod touch without cable.  It won't charge or be recognized by iTunes.  Purchased a new 1st gen cable, but still doesn't work.  Do I still have the wrong cable, or is there another problem?

  • Album view does not render correctly after synced changes

    I was correcting the album rendering of some soundtrack albums today and noticed that albums do not group correctly across computers when the metadata is synced using Match.  I am hoping someone can confirm they get the same results and possibly offe

  • Email in china and phillipines

    to send e-mails from the mac-account in china and the pillipines did not work.receiving yes...any where else, thailand etc. it is working...any ideas? thx

  • Use enhacement M61X0001 for MD01

    I want to use the enhancement M61X0001 for MRP controller wise planning for the transaction MD01. i create a proyect in cmod an activate this. I have written the example code in both the includes (ZXM61U02,ZXM61U01) of 2  EXIT_SAPLM61C_001 & EXIT_SAP

  • Starting repository browser

    Hi, Please,can one help. How to start repositry browser on linux server its urgent advance thanks subbu