Hypertrend in CVI

Dear All,
      I have developed datalogger in CVI. Presently i am using graph to view online data. I show HyperTrend control in Labview, it was very handy for datalogging and viewing application. It is also very useful to see historical data. Is there hypertrend available in CVI? Or any way to build such control?
--VP

Is this the same issue as here ?

Similar Messages

  • Cannot display square root symbol in cvi

    I don't understand why this would be an issue, but if I'm writing in the source window (with the default font of NIEditor), I cannot display a square root symbol "√" - every time I type alt+251, I get "v". Ok, not a huge deal in the source window, but it is a big deal if THAT is what's being stored in a string variable I'm writing out to a file. Additionally, if I use the following to format a string:
    "Fmt(setpointUOM, "%s<W%cT/P3", 251);", then setpointUOM = "WüT/P3". If I display this variable in a string control, it displays as "W√T/P3", which is correct, but if I use it in a Text Box or save it to a sql database, it displays "WüT/P3" which is unacceptable.
    I've tried changing the fonts but nothing works or I get even stranger results. I've been dealing with/ignoring this since CVI7 and I'm currently at CVI10. Thanks for any help.
    Solved!
    Go to Solution.

    The difference in the display between W√T/P3 and WüT/P3 has to do with the character set that you select for the UI control. From what I can tell, only the OEM code pages map the √ symbol to character 251, so if you want to see √ for that character, you should pick the OEM character set, in that control.
    Entering √ with the keyboard in a CVI window seems like a much more problematic task. When you type Alt+251 on a CVI window, the keyboard driver is converting the 251 to 118 (the letter v). I don't know why it does that, but I noticed that the code that it converts 251 to varies, depending on your input language (which you can change in Control Panel>>Region and Language>>Change keyboards or other input methods). When english is selected in the language bar, it converts it to 118. With other languages, it converts it to other codes. I tried entering the unicode value for √ directly, which is Alt+221A (to enter unicode characters using the keypad, you have to follow the steps described here). But it didn't work. It still converted it to 118. I suspect the keyboard driver is doing this because it tries to map 221A to some symbol that is valid in the code page that corresponds to the input language, isn't able to, and picks what it thinks is the closest match.
    In lots of other applications (but not all) you can type Alt+251 or Alt+221A and it works just fine. This is because those applications accept unicode characters directly. Unfortunately, CVI isn't one of them. It uses code pages (a.k.a. character sets, or multibyte sequences) instead of unicode, and symbols don't have a universal meaning; they depend on the code page.
    Even if all this were not an impediment, you'd still run into the problem that in CVI 2010 you cannot change the font of the CVI source window to use an OEM character set. So, you'd still see it displayed as a v or a ü. In CVI 2012 you can change the change it, and so if you were using CVI 2012 you could conceivably use the clipboard to paste the √, but there is a bug in CVI that is preventing OEM characters from being pasted correctly (I realize the description says that it affects tree tooltips, but it's also generally affecting clipboard operations of some less commonly used character sets).
    So, to make a long story short, I think you should continue entering the code directly with the Fmt function, at least until this bug is fixed. And make sure that all UI controls that need to display this string are using the OEM character set.
    Luis

  • Using Excel with Visual C++ 6.0 (need a graph control that behaves as much like the one in CVI as possible)

    I hate to beat this to death but I was unable to find a
    clear answer to this question.  Does NI provide Excel control from within
    Visual C++ 6.0? 
    I read that NI supports the ANSI-C library only for Visual C++ 6.0 users:
    Thread : "Re: Benifits of using measurment
    studio for VC++ 6.0?"
    NI REP : drohacek
    Quote  : "we made the decision to support Visual
    C++ 6.0 users only through the ANSI-C interface and not through the Measurement
    Studio MFC-based class libraries."
    If there is a suggested way of controlling Excel from within Measurement Studio
    for Visual C++ 6.0 then I’d love to know it. 
    If not, can a plain statement be made basically stating that if you want
    to control Excel you can’t use a Visual C++ 6.0 environment even with Measurement
    Studio support?
    With .NET of course you can just decide to have Excel support added during
    project creation.  CVI can act as an ActiveX server and easily control
    Excel just by building off the examples shipped with CVI.  I see that
    there is support, using the Measurement Studio for Visual C++ 6.0 Project Wizard,
    for taking existing CVI projects and converting them to Visual C++ 6.0 projects
    or for calling CVI libraries from a .dll from within Visual C++ 6.0.  I suppose I could do the work
    in CVI and then convert the project but I'm so deeply tied into all my MFC calls that I don't see
    how I can cleanly include the CVI libraries into my existing VC++ 6.0 projects.
    What I'm really after here is a visual graph control like the one in CVI that I
    can use from Visual C++ 6.0.  I purchased a 3rd party graph control for use
    in VC++ 6.0 that works well but isn't really visual.  I mean you can't
    enter any values in it until you run the program and fill it out programmatically. 
    Then you can see which columns are two narrow, quit the program, adjust the
    column width of your now empty control, and repeat, until you get the thing
    looking the way you want.  If I could call into Excel from within Visual
    C++ 6.0  the way I do from within .NET
    then I could use Excel to hold the table and just read in the values into my table
    control at run time.  Basically I'd use Excel as a visual development tool
    for all my tables.
    I do all my coding from within CVI and Measurement Studio for Visual C++
    6.0.  I'd use CVI for everything if I didn't depend so heavily on certain
    outside controlled C++ .dll's.  Could you please suggest then what I can
    do to get Excel support for Visual C++ 6.0?
    Last question :
    Is there any plan to ever have a NI table control like the CVI table control for
    use in Visual Studio?  One that you can
    completely set up before you do any compiling? 
    I imagine that the way Microsoft sets up their environment makes this idea impossible.  Otherwise someone would
    have come up with a truly “visual” table control before now.
    Thanks,
    Grant
    Grant M. Johnson
    Project Engineer
    LECO Corporation

    Hello Grant
    You can most certainly use Excel with VC++ 6.0. Measurement Studio won't provided you with any classes to talk to Excel in VC++ 6.0. This is because Excel allows control via Automation and you can use its automation API to do anything you need with Excel. This is what CVI uses as well.
    You can see this MSDN article on how to set this up. This mentions VC.NET, but it should work the same way.
    Here is one that talks about VC 6.0 and Excel.
    Here is a code project article about this.
    Even with .NET, you have to do thru the Excel Automation support. Excel started shipping with Primary Interop Assemblies (PIA) which are .NET wrappers about the Excel Automation object model. C++ Automation is definetely not as nice as .NET, BTW
    See this document for more information about the Excel object model.
    I would not recommend using the CVI Excel libraries if all you want to use them for is Excel automation. You will end up creating un-necessary dependencies and go through extra layers that way. You can make calls straight to Excel from VC++ without requiring CVI.
    One quick observation about your excel approach. If you decide to use Excel as your table, you might be requiring everyone who uses your application to have Excel installed on their machines. Just wanted to make sure this was acceptable to you.
    Have you looked at the Datagrid Activex control, which is one of the common controls that ships with Visual Studio? You can add it to Visual Studio by right-clicking and picking it from the list of installed activex control. If you have not already, you should check it out.
    Microsoft has made significant improvements in the number of controls they provide with .NET. They have a Datagrid control that seems to be what you need.
    Measurement Studio did add some high level classes for Excel and Word Automation that simplify some common tasks, but these exists for VS 2003 C++ and VS 2005 C++, not for VC 6.0. Underneath, we end up using the same Excel automation classes, so you can easily setup something similar for VC 6.0. Plus you can find alot of references online on how to use the Excel Automation object model with C++.
    We currently have no plans in Measurement Studio to create a table control unfortunately. I am assuming when you said graph, you actually meant table, since Measurement Studio already  provides a ActiveX graph controls for VC++ 6.0 that is very similar to the CVI graph.
    On a side note, VC++ 6.0 is really really old. Have you considered upgrading?
    To summarize
    - Yes, you can use Excel with Vc++ 6.0 without mstudio.
    - Try using the Datagrid Activex control if you just need a table.
    - Measurement Studio provides high-level excel and word classes for VC++ 6.0
    - Measurement Studio provides a graph control for VC++ 6.0 which is very similar to the CVI graph.
    - Measuremnt Studio does not have a table control.
    - VC++ 6.0 is really really old. Have you considered upgrading?
    Bilal Durrani
    NI

  • Visual Studio or LabWindows/CVI?

    I have a bit of a dilemma.
    I currently own Visual Studio 2010, IMAQ Vision Development Module 2013, and Measurement Studio (not sure of version). I currently do all of my programming in VB.net. Because IMAQ VDM is stuck in .Net framework 3.5 and there will be no further .net development by NI, I need to plan for the future. My applications need run on Win 8, 9, 43, or whatever my company decides to migrate to from Win 7.
    My understanding is that the NI modules I currently own will work with LabWindows/CVI. Correct? I also believe I can use them with C++ using the VS IDE. Is this also correct?
    Within my applications I do a lot of interfacing with Excel, writing text files, and interfacing to non-NI devices (cameras, DAQs, scanners, etc). I am able to do these things pretty easily using VB.net using vendor-provided SDK's.
    Therefore, my question is this...given the investment I have in software already, do I gain anything by migrating to LabWindows/CVI? What do I lose?
    I should point out that regardless of the path I choose I will need to bone up on my programming skills in the corresponding language.
    Thanks for all your help!

    Hello Steverino!
    Here are some advantages when using LabWindows/CVI over Visual Studio, which make the product more suitable for various industry-related applications:
    You are correct, LabWindows/CVI integrates with the NI platform: NI hardware and software, like TestStand or LabVIEW (e.g. debugging source code from one software to another, seamlessly).
    NI hardware and third-party hardware connectivity.
    OpenMP support.
    CVI integrates with intrument control.
    CVI Run-Time benefits from User Protection.
    Run-Time checking (e.g. for uninitialized variables).
    Scientific User Interface Controls and GUI Editor.
    Advanced debugging capabilities:
    Remote debugging support from ADE.
    Real-Time debugging support from ADE.
    Memory leak detection using the LabWindows/CVI Resource Tracking Window.
    Just-In-Time debugging.
    Deployment: build custom installers and patches that you can ship as stand-alone easy-to-use installers.
    LabWindows/CVI libraries: Advanced Analysis, Toolbox, Connectivity (Network Variables, Network Streams, DataSocket), etc.
    Support for LabWindows/CVI Toolkits: SQL Toolkit, Vision, PID, RT.
    Regards,
    - Johannes.

  • How can I create an application in MSVC 6.0 to access my FieldPoint modules with CVI 5.0 libraries?

    I have an application in CVI 5.0 that works. I am trying to export that so I can develop in MSVC. I need none of the UI provided in CVI, all I need are the simple FieldPoint commands provided in FieldPoint.obj. I have been stumped on this for weeks. I would write my own OPC client but the interface isn't even documented on what commands I would send if I did have an interface. I would prefer just to use the CVI libraries in MSVC 6.0. When I call the FP_Open function the program crashes with an RtlSizeHeap error.
    Thanks,
    Chad

    In theory, creating a dll that encapsulates the FieldPoint functions should work in MSVC. However, National Instruments has not tested MSVC interface, nor have we publicized that this type of setup will work, therefore making support unavailable. The other reason for why we do not offer support of FieldPoint in MSVC is that we have not seen a demand for such an interface. Therefore, I recommend that you create an OPC Client that communicates with the FieldPoint OPC Server. One example of such an OPC Client in MSVC is to use Datasockets, found in ComponentWorks++. You can find this example at the following web site:
    http://zone.ni.com/devzone/devzoneweb.nsf/opendoc?openagent&8FEAB5F73CFB68278625683A000B06ED&cat=7CDA3E51FEFC4AA2862568B80071A1E2
    If you are using the
    serial network module (FP-1000/1001), you can communicate with the FieldPoint modules using the Optomux protocol. For a complete listing of the Optomux commands refer to the FP-1000/1001 Programer Reference Manual located at the following web site:
    http://digital.ni.com/manuals.nsf/caba5d53e9b015a186256793004eebb7/bf97516ca18eee728625665e0063594e?OpenDocument
    Best Regards,
    JohnM

  • Software Development Engineer positions at Hysitron, Inc. in Minneapolis (LabWindows CVI exp preferred)

    Software Development Engineer
    Hysitron, Inc. is a premier scientific instrument manufacturer. Founded in 1992 with headquarters located in Eden Prairie, MN we are committed to promoting nanotechnology by developing advanced transducer and control technology. This leadership has made Hysitron the world leader in nanomechanical test instruments. The TriboIndenter®, TriboScope®, Ubi, and other Hysitron innovations have opened new horizons for scientists interested in investigating and understanding mechanical properties of materials at nano-scale. Hysitron fosters an environment and culture where innovation flourishes, teamwork is encouraged, and superior performance is rewarded.
    Hysitron invites applications for multiple software development engineer positions from those aspiring to explore and succeed in the nano world. Hysitron, Inc. is an Equal Opportunity Employer M/F/D/V
    Job responsibilities
    The software development engineers would be responsible for developing test and measurement software applications for nano-mechanical testing instrumentation. Job deliverables would include:
    -          Develop software applications in C based Labwindows CVI for Hysitron Instrumentation
    -          Support the development of applications to address challenges in instrument automation and control
    -          Test software applications using debugging and simulation tools
    -          Perform software releases and software quality assurance activities
    -          Participate in the design of new software products
    -          Perform maintenance activities for existing products
    -          Adapt and deliver on quality software development practices
    Minimum qualifications
    -          BS in Computer Science/ Computer Engineering/ Equivalent Scientific or engineering discipline
    -          Min of 3 yrs experience in Instrumentation software development in an industrial or R&D environment
    -          Expert at programming language C, knowledge of C++
    -          Working knowledge of various communication protocols, e.g. USB, RS232, IEEE, RS485, TCP/IP, Modbus
    -          Knowledge of general software design/documentation processes in test and measurement systems
    -          Proficient problem solving skills
    -          Strong analytical and technical skills
    -          Excellent communication and interpersonal skills
    Preferred Qualifications
    -          Proficient with LabWindows CVI and XML
    -          Working experience with DSP(Code Composer Studio) and/or FPGA level programming
    -          Exposure to digital electronics and instrumentation
    -          Working experience in Robotics interface programming
    -          Experience with Controls/Automation engineering
    Application and Information
    Qualified candidates should send a letter of application and their resumes to (please include ‘SW Engineer’ in subject line):
    Hysitron, Inc.
    10025 Valley View Rd
    Eden Prairie, MN 55344 USA
    Phone: (952) 835-6366
    Fax: (952) 835-6166
    E-MAIL: [email protected]
    Web: www.hysitron.com

    This position is still accepting resumes/CVs.

  • How do I send e-mail to a distribution list using LabWindows/CVI?

    I need to be able to send e-mail to a user-defined distribution list using LabWindows/CVI? Has anyone done this? Any ideas where I could look?

    I commented on something similar to this awhile back.  My issue was that I had the base version and didn't have the Internet classes.  So this external app worked like a charm
    It has a lot of command-line inputer options to use as well.
    http://forums.ni.com/t5/LabWindows-CVI/Need-Help-for-Sending-Email-with-LabWindows-8-5-or-9/m-p/1095...

  • How to use CAN256 and CAN257 in Labwindows CVI?

    I am trying to learn about CAN programming in LabWindows CVI. None of the samples do anything other than generate cryptic error messages. I do not have a card or interface device yet, but reading in the help files I found this:
    "NI-CAN provides a virtual CAN card with two interfaces, CAN256 and CAN257. The two virtual interfaces are connected by a virtual bus. When you write CAN frames to one virtual interface, those frames are received by the other virtual interface, and can be read as channels. This feature allows you to read and write CAN data in the same manner as two real CAN interfaces connected by a real CAN cable. The conversion does not require real NI CAN hardware, and your application is not required to check for specific CAN IDs."
    I modified the Waveform ouput project and add CAN256 to the dropdown in the uir file. However when I run it, I get the same error message as always, error -1074388725.
    Is there an example CVI code someplace to demonstrate the use of these virtual channels?

    Thanks Drew.
    Ultimately, my customer provided me with a WriteCAN256.vi and ReadCAN257.vi that were perfect for my needs. The WriteCAN256.vi along with my NI USB 8473s allowed me to provide data collection on multiple CAN devices and to verify that my Software can handle all data types from CAN devices.
    Note: My customer allowed me to share his .vi's. They are enclosed ...
    Best Regards,
    Don W
    Attachments:
    CanBus Read (Frames)_85.vi ‏55 KB
    CanBus Write (Frames)_85.vi ‏48 KB

  • How to use the checksumdll.lib in LabWindow/CVI to create CRCChecksum();

    Hi All,
    Any one know how to use the checksumdll.lib in LabWindow/CVI to create CRCChecksum() ?
    Thank you.

    Do you ave some documentation about that dll?
    Have you looked into dll properties searching for vendor name? Maybe you can look int vendorìs site and obtain some help.
    Ultimately: are you forced to use that dll or can you use any software to calculate the checksum? There are several CRCs that you can use: provided you know which is the type used you could find an algorithm to calculate the CRC and check an existing one.
    Proud to use LW/CVI from 3.1 on.
    My contributions to the Developer Zone Community
    If I have helped you, why not giving me a kudos?

  • How to set a DMA transfer type for PXIe-6536 in LabWindows/CVI?

    I have a PXI chassis PXIe-1078 with a controller PXIe-8115 running under Windows 7. The digital output board is PXIe-6536.
    I use a function DAQmxSetChanAttribute to set a property DAQmx_DO_DataXferMech to a value DAQmx_Val_DMA, since I want to use a direct memory access data transfer. This wokred well with a PCI-6534 board using the same LabWindows/CVI code before migrating it to the PXIe system.
    Unfortunately, running this code on the PXIe system reports a DAQmx error -200452: "Specified property is not supported by the device or is not applicable to the task".
    The task is created in the following simple way (the board name in MAX is 'Dev1'):
       DAQmxCreateTask ("digTask", &digitalTask);
       DAQmxCreateDOChan (digitalTask, "Dev1/port0:3", "DIG_CHANNELS", DAQmx_Val_ChanForAllLines);
       DAQmxSetChanAttribute (digitalTask, "", DAQmx_DO_DataXferMech, DAQmx_Val_DMA, 15);
    How can I solve this problem? How is it possible to choose between different transfer types?
    Thank you in advance for any hint!

    Hi CavityQED,
    The PCI-6534 is a "Digital I/O" board while the PXIe-6536 is a "High Speed Digital I/O" board, that's why they don't have the same properties.
    By the way you can use DMA transfer with this method :
    http://zone.ni.com/reference/en-XX/help/370520J-01/hsdio/direct_dma/
    Let me know if it helps you.
    Regards.
    Mathieu_T
    Certified LabVIEW Developer
    Certified TestStand Developer
    National Instruments France
    #adMrkt{text-align: center;font-size:11px; font-weight: bold;} #adMrkt a {text-decoration: none;} #adMrkt a:hover{font-size: 9px;} #adMrkt a span{display: none;} #adMrkt a:hover span{display: block;}
    LabVIEW Tour
    Journées Techniques dans 10 villes en France, du 4 au 20 novembre 2014

  • How can I convert a project from LabWindows/CVI 2010 to a Visual Studio 2011 project?

    I have a good sized project, 12 source files, 14 headers, 1 uir, that I want to be able to edit and compile in MS Visual Studio 2011, MSVC++.
    I remember being told that LabWindows dropped support for C++ in 2008 and no longer had a wizard for converting projects. I know I can go the DLL route, but I have never created a DLL before and wouldn't know where to begin with it. What would be the best way to go about this conversion?
    Solved!
    Go to Solution.

    CVI 2010 still supports the Visual Studio Conversion Wizard for Visual Studio 2005/2008. We do plan to add support for VS 2010 in a future release.
    If you need a VS 2010 project now, you can use the Visual Studio 2008 conversion wizard, then upgrade the VS 2008 project to VS 2010.
    National Instruments
    Product Support Engineer

  • How can I debug a DLL created with MS Visual Studio C++ using CVI?

    I have developed a DLL using MS Visual Studio C++, which is called by an other application written in CVI.
    My goal is to debug the DLL written with C++ when is called from CVI.
    So far I have some msg popups, but I would like to have more debugging capabilities.
    Thanks, Adalbert

    Hello Adi11,
    As documented in the CVI Help under "Debugging DLLs": "In the LabWindows/CVI development environment, you can debug only DLLs you create in LabWindows/CVI with the Create Debuggable Dynamic Link Library command. Other development environments cannot debug DLLs you create in LabWindows/CVI."
    This information was also mentioned on the following discussion forum.
    Thanks.
    Wendy L
    LabWindows/CVI Developer Newsletter - ni.com/cvinews

  • How can I prevent NULLs from appearing in my HyperTrend graph when restarting DSC engine?

    I am continuously logging data to a citadel database using DSC 7.0. Occasionally I need to restart the DSC engine because of a computer reboot, changes to SCF file, etc. Whenever I do this, and then review the data in HDV or with a HyperTrend graph in LV, there is a discontinuity in the traces during the time the DSC engine was not running. Using the cursors, you can see the value during this time is NULL. Generally this is desirable behavior since it indicates that no data was collected during this time period. However, I would like to know if there's setting to just "connect the points" instead of having a NULL in between. The reason is that some memory tags are updated very
    infrequently, so the discontinuity appears much longer than just the time the DSC engine was not running. I want to connect the line to make the graph look nicer.

    I assume that you mean pop-up windows that might be left unnoticed when they are opened behind the current Firefox window.
    You can modify the behavior and change these prefs to open all links in tabs:
    *http://kb.mozillazine.org/browser.link.open_newwindow<br />1: current tab; 2:new window; 3:new tab;
    You can change the value of the browser.link.open_newwindow.restriction pref to 0 to open all JavaScript window.open() calls in a tab
    *http://kb.mozillazine.org/browser.link.open_newwindow.restriction
    You can open the <b>about:config</b> page via the location bar and accept the warning and click "I'll be careful" to continue.
    *http://kb.mozillazine.org/about:config

  • How can I get HyperTrend to display the numeric value output of a CHOOSE statement?

    I have non-linear values I need to display on a HyperTrend graph.  I'm currently converting the input raw signal to a Units (Engineering) value and then looking up the actual value (from a calibration chart) using a CHOOSE statement in order to display the actual value on a panel, but I need to display the values output by the CHOOSE statement on a HyperTrend graph, along with other similar values.
    How can I do this?

    I have non-linear values I need to display on a HyperTrend graph.  I'm currently converting the input raw signal to a Units (Engineering) value and then looking up the actual value (from a calibration chart) using a CHOOSE statement in order to display the actual value on a panel, but I need to display the values output by the CHOOSE statement on a HyperTrend graph, along with other similar values.
    How can I do this?

  • How to get bar graph in word in labwindow/CVI ?

    how to get bar graph in word in labwindow/CVI ?

    ashwinic9,
    spawning your question over more and more threads (the present one, this one and this other one) won't give you a faster answer; instead, it will irritate forum users! 
    Especially if you have at your disposal a fast way to perform a test. I pointed you some days ago to word report example, that writes a table to a word document: did you tried changing the graph into a bar graph and generating the report? I have done it for you and the result is OK, as you can see in the attached document.
    Now, since the example works well, there must be something in your particular situation that prevents the graph to be shown; that is: you must add some more data on your actual problem and maybe a small example that exposes the problem.
    But please: keep active only this discussion and let the other threads die! 
    Proud to use LW/CVI from 3.1 on.
    My contributions to the Developer Zone Community
    If I have helped you, why not giving me a kudos?
    Attachments:
    wordreport.doc ‏38 KB

Maybe you are looking for

  • How to Create AP Invoice from PO using SDK

    Hi, I want to create an A/P Invoice thru SDK for which already the Purchase Order has been entered thru the front-end. How to do it? Using SBO objects I am loading the particular PO. But after that how to transfer everything in the PO to AP Invoice.

  • How to share remoteclass with netGroup?

    Hi! I try to share instance of a class between two applications but the message receive is just an object and not the instance of the class and when I try to convert it into a class, I get a "null" value. Here some infos about what I done: a exemple

  • Backup / sync icon remains red

    Even when i login to PS.com when i launch Organizer, the backup/sync icon remains red. When i click on icon for backup/preferences setting, it tells me to login again.

  • I can't install Firefox. Get a message saying "can not open output file" Firefox version 3.6.6

    Firefox stopped working after updating. I uninstalled it and downloaded latest version 3.6.6. Before that 3.6.3. When I try to install, I get a message "Extraction Failed.. Can not open output file" . I trie d former versions, all with the same resul

  • AEBS Fast Ethernet vs Gigabit

    Hi all, I have a fast ethernet AEBS-80211n and was wondering if there was much difference between mine and the newer gigabit version especially in airdisk speeds. Now im using it for time machine writing to the airdisk is painfully slow even over eth