Hi All,
In Hr ABAP we will start basic coding with
TABLES pernr . 
infotypes:0002.  
By using this I am getting the following SLIN Error :
Program:  ZHCP0026  Row:     32
he current ABAP command is obsolete
Within classes and interfaces, you can only use "TYPE" to refer to ABAP Dictionary
types, not "LIKE" or "STRUCTURE".
nternal Message Code: MESSAGE G/B
(The message cannot be hidden using pseudo-comment "#EC .., bzw. durch SET
EXTENDED CHECK OFF/ON)
INFOTYPES : 0380,
The current ABAP command is obsolete
Tables with headers are no longer supported in the OO context.
Internal Message Code: MESSAGE G1D
(The message cannot be hidden using pseudo-comment "#EC .., bzw. durch SET
EXTENDED CHECK OFF/ON)
Can some one help me , how to rectify this slin error ?
Thanks,
Suresh.
Edited by: suresh kumar on Feb 25, 2009 2:22 PM

Hi Suresh,
Am too facing the same problem. if you could find a solution, pls let me know.

Similar Messages

  • Getting an error in ECC 6.0 when open table MARA

    Hello  Experts,
    In ECC 6.0 while opening  table MARA, I am getting an error
    "Inconsitency inthe Dictionary for the structure "Mara"."and  so on for other tcodes. This error I am getting since yesterday, previously I was not getting such error. Can anyone help me in this regards.
    Thanks & Regards
    Chetan Chauhan

    Did you change something in your system? Installed support packages or other things?
    check the structure MARA by executing
    - SE11
    - MARA
    - Utilities - runtime object - check
    Markus

  • SAP-Documentum Interface - getting an error as: Could not create PLM DIR.

    Hi all,
    We are facing following problem with the interface of SAP-Documentum.
    While linking multiple DIRs from Documentum, getting an error as: 'Could not create PLM DIR. (E26324) (Error in version number increment for version 00)'.
    Observation:
    It's getting failed in 'DIR_GET' every time, so attempts to create new DIR every time.
    Note:
    Recently upgraded to SAP ECC 6.0 EHP4.
    Please help.
    Thanks.

    Sachin,
    There are couple of things you could do:
    1) Try the same values and execute linking manually in sap by calling BAPI_DOCUMENT_CREATE2 in se37.
    2) Try pre-pending zeros to the equipment number field using WebAdmin on Documentum side.
    Send me a message if you need additional help. I have been working with Documentum-SAP integrations for over 10 years and pretty much seen every problem out there
    Sachin
    http://documentum-sap-expert.blogspot.com/
    Edited by: Documentum-SAP-Expert on Jul 20, 2010 2:56 AM

  • User is getting critical error while accessing ESS

    Hi Experts,
    User is getting critical error message while accessing ESS tabs ( working time , career and job ...etc ).
    User account in PORTAL  as well as in the ECC Backend is fine.(105 infotype is maintained).
    User has valid roles also.
    Can anybody please help me in solving this issue.
    Thanks
    Thirun.
    Edited by: Thirunv on Oct 26, 2009 2:16 PM

    Hi,
    1.Is this related to only one user or all the users?
    2.Did you check the permissions on the system object used to access the ECC box.
    Cheers!
    Sandeep Tudumu

  • How to get Application Error descriptions

    Hi, all:
    Our interface has ECC system involved.
    The Message Monitoring in local integration engine shows that there are many messages with application errors.
    I would like to export all messages with application error:
    include message ID and error text.
    Right now, I can export the data from Message monitoring window, but I can not get application error from exported spreadsheet. anyone has idea how to do it ?
    Thanks in advance !
    Liang Ji

    Hi, venkata:
    Thanks for you reply.
    Our scenario is
      ThirdPartySystem ---> SOAP ---> XI ---> ECC (ABAP Proxy)
      Technically, the scenario is running perfect.
    After go-alive, there are many application errors because of the data problem,  e.g.:
    Cannot create order. Service order number already exist
    We know these problem are caused by conversion, now I would like to track each message, so I exported to spreadsheet from Message monitoring.
    But the exported spreadsheet does not include Application Error text, this is the reason I post the question here, do you have idea about it ?
    Thanks
    Liang

  • Getting Msg: Error when calling Credit Management: Technical Error

    Hi All,
    While creation of sales order in ECC, i am getting a message "Error when calling Credit Management: Technical Error"
    Can you help me in this case
    Regards,
    Satish

    Satish,
    Just so you know, this BADI "links" SD module to FSCM credit management. If you use the right code in this BADI, it copies over credit information on to the sales order such as Credit Account, Risk Class and Credit representative code.  (Later this risk class, order's credit control area and credit group is used to look up the appropriate line in OVA8 settings)
    Now you could be getting this error for any of the issues:
    1. If the business partner is not created for the customer for which you're trying create a sales order (The credit account (sales order header) should have a relevant BP already) Check if the BP is correctly created.
    2. Next if the credit data has been maintained for the BP in credit management.
    3. XI/PI connectivity issues etc
    Check if all this is maintained and you should be good. Cheers

  • QRFC & Ignore icon is not responding when i get a error message

    Hi,
    When i activate a integration model. In case if i am getting a error message due to some missing of data in APO or due to incorrect data in ECC. System throws the error message, in that popup i can see the error message and there is three icons qRFC monitor, Ignore & cancel. Only cancel icon is working the rest is not working when i click it stays in the same screen without any response.
    Am i missing any settings or something else is required to active this.
    Awaiting for reply
    Thanks & Regards
    Shan

    Hi Shan,
    Depending upon the error message, the system will allow you to go
    further.
    If the error is minor, if you say ignore, it will try to activate the model.
    If it is major, it will not allow you to ignore.
    You will have to go into the inbound/outbound queue, take corrective
    actions for the errors caused and then reset your queues.
    Once this action is done, try activating the model with all
    authorisations.
    Regards
    R. Senthil Mareeswaran.

  • External program interfaces SLIN Error

    Dear Experts,
                      I am getting SLIN External program interfaces error . could you please tell me how to correct the  error ?
      *LOOP AT lt_p0001 INTO ls_p0001."
          SUBMIT yhrin_rhstru00 WITH pchwegid = 'O_S_P' WITH pchobjid-low = ls_p0001-orgeh "#EC *
          WITH pchbegda = '19000101' WITH pchenda = '99991231' WITH pchplvar = '01'
          WITH pchotype = 'O' AND RETURN.
          EXIT.
        ENDLOOP.*
    Regards,
    Sivakumar.A

    Dear experts ,
      I am receiving the following SLIN Error Message.
    Program:  SAPLYHRIN_MSSDB_ENH  Include:  LYHRIN_MSSDB_ENHU06  Row:    129   (Prio 1)
    PCHOBJID-LOW is not a parameter or a select option in report YHRIN_RHSTRU00
    (The message can be hidden with "#EC *)
          Program:  SAPLYHRIN_MSSDB_ENH  Include:  LYHRIN_MSSDB_ENHU06  Row:    129   (Prio 1)
    PCHENDA is not a parameter or a select option in report YHRIN_RHSTRU00
    (The message can be hidden with "#EC *)
    Thanks and Regards,
    Sivakumar.A

  • Report SLIN Error need to be removed

    Hi All,
    I am getting the below SLIN error while doing extended program check.
    How to rectify this error.
    Use addition UNIT when outputting IT_TAB-MENGE
    Use auxiliary field when outputting with MESSAGE
    Regards,
    Viji.

    Hi,
    Try using  IT_TAB-MENGE UNIT 'USD'.
    Regards,
    Arati.

  • SLIN Error

    Hi All,
    I am getting an error as :
    Syntax check warning
    This warning is only displayed in SLIN
    Assigning to "POSNR" may result in information loss
    the ine where i am getting error is :
      LOOP AT t_temp_all ASSIGNING <fs_temp_all>.
        READ TABLE t_rev_all INTO w_rev_all WITH KEY bukrs = <fs_temp_all>-zccode
                                                     vbeln = <fs_temp_all>-zcontnum
                                                     posnr = <fs_temp_all>-zcontitm.
    Please help me in understanding where i am wrong.
    Thanks,
    Poonam

    Hello,
    Check the length of POSNR and the field zcontitm. If zcontitm is longer than POSNR, this warning will occur, and of you are sure that no data will be cut off, you can ignore this warning.
    Vikranth

  • SLIN ERROR in REPORT

    Hi All,
    I am getting the following SLIN error for my report.
    Code Snippet.:
        LOOP AT i_ekes INTO wa_ekes WHERE ebeln = wa_po-ebeln
                                    AND   ebelp = wa_po-ebelp.
          AT END OF ebelp.
            V_CARRY_501 = c_x.
          ENDAT.
    SLIN Error:
    The LOOP statement processing will be limited
    (FROM, TO and WHERE additions in LOOP)
    Interaction with group change processing (AT NEW, ...) is undefined
    Points Assured,
    Regards,
    Viji.

    Hi,
    As per SAP documentation u should not use AT events with where clause. SAP will not give guarenty on the functionality.
    Replace the logic like below.
    SORT i_ekes BY ebelp.
    LOOP AT i_ekes INTO wa_ekes.
    CHECK wa_ekes-ebeln = wa_po-ebeln
    AND wa_ekes-ebelp = wa_po-ebelp.
    AT END OF ebelp.
    V_CARRY_501 = c_x.
    ENDAT.
    ENDLOOP.
    Also at what position is the field EBELP?
    If it is not the first field then till that field it takes the key.
    eg: EBELP is 3rd field in ur itab then when ever field1 or 2 or 3(EBELP) changes then control enters to AT event.
    Another way could be like this.
    i_ekes_temp [] = i_ekes[].
    DELETE i_ekes_temp WHERE wa_ekes-ebeln NE wa_po-
    ebeln AND wa_ekes-ebelp NE wa_po-ebelp.
    SORT  i_ekes_temp BY ebelp.
    LOOP AT i_ekes_temp INTO wa_ekes.
    AT END OF ebelp.
    V_CARRY_501 = c_x.
    ENDAT.
    ENDLOOP.
    I feel first approach is better.
    Hope it is clear.
    Thanks,
    Vinod.
    Edited by: Vinod Reddy Vemuru on Aug 26, 2008 6:17 PM

  • Slin error : 'T005t' is enhanceable..........issue

    Hi All,
    Im getting this slin error :
    "T005T'' is enhanceable.After a structural enhancement, the semantics of the
    parameter might change.
    and other error is :
    "BUT0ID" is enhanceable. Enhancement can lead to offset shifts when passing RFC
    parameters.
    There are structures referencing these types and are defined in parameters of the Function module.
    Please anyone how can i remove these errors?

    Hi Ujjwal,
    Check the HELP from SAP link.
    [http://help.sap.com/abapdocu_70/en/ABENUNICODE_STRUCTURES.htm]

  • SLIN Error and warnings

    Dear Experts,
                         I have created  table maintenance generator for my custom table that generated two function module and necessary includes.
    I am getting Obsolete Statements EPC (SLIN) Error and warnings due to the auto generated includes in my function group while checking the extented program check.
    I could not reduce the EPC errors and warnings because that referring the register object.
    Could you please give your suggestion to reduce the EPC Errors and warnings?
    Thanks in advance.
    Warm Regards,
    Sivakumar.A
    Edited by: Sivakumar Arumugam on Oct 11, 2008 12:59 PM

    Dear Deepak Paramashetty,
                                              I did not get any problem ignored the warnings no other way.
    Regards,
    Sivakumar.A

  • Getting PRA error OIUME 017

    Hi, I am getting an error message OIUME 017 while creating a Measurement Point.
    Measurement Source is WCMP, but I cannot find any customizing that links Measurement Source WCMP with Measurement type FLEX_MP
    Thank you,

    Hi Paulo,
    All the OI_PRA* and OI_COM* (CUNI Tables - UoM related updates) related BC sets needs to be activated. From your screen shots on the Flex_MP is mainly occurring because measurement system related BC sets has been activated.
    Please use the instructions given in OSS Note: 868771 -  SAP ECC Industry Extensions: Copy Special Customizing / OSS Note: 908007 - Special Functions in Switch Framework /SFW5 for activating the BC Set.
    Hope this clarifies.
    Thanks,
    Muthu

  • When logging as recruiter getting "Internal error occurred"

    Hello,
    We are running Erec & ECC on different systems.
    When logging as recruiter in Erec prd system getting "Internal error occurred" -
    I checked the SGL1 -
    1.) The error occurred in program CL_HRRCF_ABSTRACT_CONTROLLER==CM001 line 56
    2. ) The error occurred in program CL_HRRCF_START_A==============CM007 line 19
    Please help me how to go with this...
    Regards,
    Poornima

    Hello,
    No the note doesnt help.
    Any other clue what could cause the error?
    Regards,
    Poornima

Maybe you are looking for

  • Mp3 and RecordStore Capable Emulator

    Currently I'm trying to develop an application that plays back mp3's. I am just wondering if there exists an emulator that can handle both, record sets and mp3 playback. WTK22 does a good job of handling recorcStores, but can not handle Mp3 playback.

  • How to insert the partner link (xml)response to data base adapter in BPEL:

    Hi to every one, I have little bit knowledge in oracle SOA suit and having knowledge in java technologies, I am developing one central reporting server for this I have the following requirement. I need to call ‘N’ departmental servers (partner links)

  • When will come the new imac 27 inch in europe(Österreich)

    guys when will come the new imac 27 in europe? Österreich

  • Regarding process chin.

    Hi all, If i am using process chin then how can i ensure that the data is uploaded in to PSA,ODS and infocube. I mean is there any log facility for this.. thanks,

  • Linksys BEFW11S4 v4

    Hi, I have a Linksys BEFW11S4 that works just fine, or so I think. Currently there are 2 desktops and a PS3 connected to the router via cat-5. One desktop has Win Vista/Win 7 (both 32-bit Home) installed and the other desktop has XP Home. I recently