Is there a way to read the system DoubleClickTime double-click%3F

Hi,
I'm doing some customized actions on a tree if a user "slow-double-clicks" on a valid tag in the tree. My current solution works, but I would like to set the "limit" or interpretation of what constitutes a "slow" double-click based on the system DoubleClickTime setting of the system that the program is running on.. Anyone knows how to read this piece of information on a) windows system or b) any system?
Please note that due to what I'm trying to accomplish, I cannot use the "double-click" event to make this determination.  (Double-clicks are left alone to do whatever they would normally do.)
Microsoft MSDN on Double-clicks
--I guess a more general form of the question would be "how to read out windows system settings in LabVIEW".
For the specially interested, my program is an event driven queue machine. When I get a mouse up on the tree-control, I pass the ms timer to an action engine (get, set, re-set) which tracks delta time between two clicks and passes out an enum of "click type" (as defined by me) as either n/a, single, double, slow double.
In my queue handler loop, I take the click message (from event loop), do some basic checks (is tag of the tree coordinate location empty string?) and pass it all along to another state that determines what to do based on click type, parent(s) (or indent level) and column.  The need for this "slow-click" feature came about when I needed to let the user re-name a parent level tag-item.. If you double-click normally on a parent, it will expand or collapse its children list. . In some applications, (windows explorer for example), the default double-click action (open the file) can be "changed" to a "rename" function by clicking a little slower. Clicking too slow will be interpreted as a "single" click (e.g. select).
QFang
CLD LabVIEW 7.1 to 2013

How about now?
The clue is in tst's post above, its under .net, windows.forms http://msdn.microsoft.com/en-us/library/system.windows.forms.systeminformation.doubleclicktime.aspx
Beginner? Try LabVIEW Basics
Sharing bits of code? Try Snippets or LAVA Code Capture Tool
Have you tried Quick Drop?, Visit QD Community.

Similar Messages

  • I have written a binary file with a specific header format in LABVIEW 8.6 and tried to Read the same Data File, Using LABVIEW 7.1.Here i Found some difficulty.Is there any way to Read the Data File(of LABVIEW 8.6), Using LABVIEW 7.1?

    I have written a binary file with a specific header format in LABVIEW 8.6 and tried  to Read the same Data File, Using LABVIEW 7.1.Here i Found some difficulty.Is there any way to Read the Data File(of LABVIEW 8.6), Using LABVIEW 7.1?

    I can think of two possible stumbling blocks:
    What are your 8.6 options for "byte order" and "prepend array or string size"?
    Overall, many file IO functions have changed with LabVIEW 8.0, so there might not be an exact 1:1 code conversion. You might need to make some modifications. For example, in 7.1, you should use "write file", the "binary file VIs" are special purpose (I16 or SGL). What is your data type?
    LabVIEW Champion . Do more with less code and in less time .

  • Is there any way to use the system font?

    Firefox for Android uses a font that is not the default Android system font (Roboto), and I would much prefer to use that font. Is there any way to change the font Firefox for Android uses?

    in about:config search for font.name and alter the values such that Clear Sans is listed after Roboto/Droid.

  • Is there a way to change the default action for clicking a "Print" button on a website to open Print Preview instead of the default system printer?

    When I am at a website that contains a button for printing (Gmail, for example), is there a way to change the way that functions, so that when I click "Print", Firefox will open Print Preview instead of taking me to the default system printer?

    You can apply  system-wise "negative" color effect under Settings > General > Accessibility, by toggling the White and Black switch - and, in iCab Mobile (and some other, better browsers / PDF readers), its own "night mode" negative color scheme.
    Otherwise, no, you can't do anything else except for asking third party app authors to add selectable back/froeground (=text) colors to their apps.
    There is an article dedicated to this question: http://www.iphonelife.com/blog/87/do-you-find-your-idevices-screen-be-too-blueis h-or-just-too-harsh-bedtime-reading

  • Is there a way to read the RTE version of an executable without opening it?

    All,
    I'd like to find a method of determining which runtime engine is needed to run an executable programatically.  I'm working on an auto-updater program and have read dozens of forum posting on the topic.  I've found the Application property node for version number in the DevEnvr, and the FileVersionInfo.VI to read the build version number, etc. in the RTE.  The coding for updates within the same RTE is done and works fine.
    The one thing that is absent from all of the postings is a technique to determine the RTE needed to open and run an executable.  Is one out there?
    I've already got the code working to install the new version of RTE, but I'm at the last (skipped earlier) step of determining when that is needed.  Right now I've resorted to writing it in the build properties version information description and parsing it out.  I fear this flimsy work around could be easily missed on the next upgrade if someone doesn't read the documentation and include it.
    I just found this Idea Exchange  which looks like a suitable solution is going into NI R&D as of a couple days ago.  But until that is released, is there a more robust way of determining this?
    Solved!
    Go to Solution.

    Here's a recent thread about this:http://forums.ni.com/t5/LabVIEW/LabVIEW-Version-of-Built-Executables/td-p/2162718
    In short, we found a way to read the EXE as a text file and performed a search for a specific pattern.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • Is there any way to customise the system generated packing slip?

    Hi All,
    My customer would like to be able to add a few field to the system generated packing slip. I can see where to update things on the invoice in system emails, but couldn't see anywhere for the packing slip?
    Also there's a few random bits that get printed on the invoice that aren't part of the system invoice. Any idea how to remove? My client is printing from Chrome. See below:

    Thanks for replying @thetrickster888,
    Tried all 4 tags but none showed the phone or email on the packing slip
    {tag_addressbilling}
    {tag_addressshipping}
    {tag_recipientaddress}
    {tag_emailaddress}
    We use a pretty standard Registration-buy form and have the phone line as:
    <td><label for="HomePhone">Phone Number </label><br />
                    <input type="text" maxlength="255" class="cat_textbox" id="HomePhone" name="HomePhone" /></td>
    But still doesn't show on the packing slip. I don't know what else to do.
    I can get them all to show on the invoice but not the packing slip. The only thing I can think of is to give the factory the invoice - but then it's not set up well enough for them to mark off the checks when it's made and packed (we have special boxes on the packing slip for this) plus then they can see pricing which we try to avoid.

  • Is there any way to read the pdf file in java

    Hai,
    i need some advice from anyone that is there anyway to read the pdf file directly from java...
    Without converting to other files(txt,html)
    if it is possible please help me..
    Thank you

    Or use the Adobe one (search the adobe site). Or search this forum, this is one of the Top Ten Qestions Asked here.

  • Is there any way to read the field name,through the property binded to it.

    Hi
    I want to know that,is there any method exits with which i can find the field names of the screen,if i have the property attribute with me.
    as my req is to make the validation for the property attr,& check  how many fields are binded with the single property attr,i have read the property attr dynamically,now need to find the fields linked,& need to check how many fields have not field value,& through the error msg.

    just read the attribute binded to properties using code wizard ( Control + F7).
    Code generalted will be like :
    DATA lo_nd_cn_check TYPE REF TO if_wd_context_node.
        DATA lo_el_cn_check TYPE REF TO if_wd_context_element.
        DATA ls_cn_check TYPE wd_this->element_cn_check.
        DATA lv_ca_check LIKE ls_cn_check-ca_check.
      navigate from <CONTEXT> to <CN_CHECK> via lead selection
        lo_nd_cn_check = wd_context->get_child_node( name = wd_this->wdctx_cn_check ).
      get element via lead selection
        lo_el_cn_check = lo_nd_cn_check->get_element(  ).
      get single attribute
        lo_el_cn_check->get_attribute(
          EXPORTING
            name =  `CA_CHECK`
          IMPORTING
            value = lv_ca_check ).
    Here i have read attribute CA_CHECK.

  • Is there a way to disable the ability to double-tap to create a straight line in Photoshop?

    Hi,
    I have a problem in Photoshop CS6 where whenever my pen double taps the tablet, windows will do the "loading" circle where my cursor is, and I can drag the brush anywhere, and will still have control over the opacity and size, but once I let go, a hard line of 100% thickness and 100% opacity is created between the starting and ending points. Here is an image of what I am talking about:
    http://i.imgur.com/2yO1yIW.jpg
    This is a very annoying problem when I am trying to draw, because often times I will finish one short stroke and begin another immediately, only for a blob of 100% opacity to appear. It happens to me almost every 2 minutes.
    Now, I don't know if this is a problem with Photoshop, my tablet, or my computer. Does anyone know if this is a feature that can be turned off? Or has experienced this problem and has a solution? Thanks.
    Specs:
    Windows 8.1 Pro
    Photoshop CS6
    Wacom Intuos Pro
    AMD FX 8320 / nVidia 650 Ti Boost / 16GB RAM

    Found a fix. It's not a photoshop problem, but a Wacom option. Go into the Tablet control panel > pen > set "double click distance" to Off. Hope this helps anyone who needs it!

  • Is there any way to read the data from an excel file w/o using a loop structure?

    I am retrieving a large amount of data (multiple sheets) from an excel file and would like to extract the entire range without retrieving individual cell values(too slow). I can write an range all at once but cannot read it.

    If you are able to write a block of data, then you should be able to read a block. The four requirements that you want to verify are:
    1. The Range specified must match the exact size and location of the data block you want to read
    2. The returned data is in a 2D array of Variants (either strings or numbers)
    3. Use Variant to Data to convert to 2D DBL or 2D Strings
    4. Check for the correct orientation for your application (use transpose if it is not)
    Michael Munroe
    Certified LabVIEW Developer
    www.abcdef.biz
    Michael Munroe, ABCDEF
    Certified LabVIEW Developer, MCP
    Find and fix bad VI Properties with Property Inspector

  • I lost my iphone 4 yesterday , is there any way to destroy the system of it using the serial number? Also , Can thieves access my photos or private things even if there was a passcode on my iphone?!

    Please help me ,I am really worried !

    Maha1992 wrote:
    Unfortunately I did not install find my iphone in the lost iphone so I cant  use it . Can they restore the information and photos easily?! I mean the computer does not ask them for the passcode or the password of the apple ID inorder to complete the process of restoring?!
    If they do restore it in iTunes, that process is going to wipe all your content from it, so your information would be gone.  Yes, they can then go on and use your device as theirs, but your information is wiped from it at that point.
    For future reference, along with the passcode, you can set it to erase everything after 10 failed passcode attempts.  As long as you have regularly sync'd content back to your computer and maintained an up to date backup, you have safeguarded your content for your own recovery and use.
    And in iOS 7 an iCloud account and find my phone activation is worth it just for Activation Lock, even if you don't care about any other iCloud features (all of which you can simply disable and not use if you choose to).

  • Is there any way to read the Value mapping input values dynamically?

    Hi all..
    I have a scenario where i have used value mapping. now the issue is when the input is not having any corresponding output value in value mapping then i should get null as output. can anyone suggest how can this be achieved?..
    Regards
    Anu.

    Hi,
    Do you know if the value in not maintained/found in the value mapping then it returns the same value as a result at runtime.
    So, simply if and else will help you to get your desired result..
    SourceField ---> ValueMapping------>|
                                        |----->equalS---IF---->Then -----> Map constant (null) ----> Target
    SourceField------------------------>|
    Else ---->map (SourceField ---> ValueMapping) --->Target.
    Regards,
    Sarvesh

  • Is there a way to modify the file name when clicking the pdf button to be different

    I wish to have the default name to something like document type_document #.

    Hi,
    Only possible when you export through File--->Export--->PDF. If you directly click PDF icon, system will store with default format.
    Thanks & Regards,
    Nagarajan

  • Vehicle stuck in Yard Management - Is there a way to change the HU Status?

    Hi Everyone,
    I'm trying to remove a vehicle that's stuck in Yard Management (under a warehouse) but I had no luck so far. The problem is that the Handling Unit was set to deleted and I haven't been able to change its status through HU02 or even using HUMO. The system status right now is DLTD. When I try to delete the vehicle in YM, it says that I can't because of the status that's in right now.
    Is there a way to change the system status back to 'PLND' for example?
    Also, if I could find a way to set the user status, would it prevail over the system status?
    If more information is needed, I'll gladly provide it.
    Thanks everyone!

    Hi Petr,
    Thanks for replying.
    I tried using this transaction but I don't think it's implemented in my company's SAP version.
    I think I found what the problem is. In VEKP, the status field (VEKP-STATUS) is set to '0001' (Planned) instead of 0060 (Deleted). But if I display it using tcode HUMO, it shows up as 'DLTD'. Maybe the issue is that both status are not in sync with each other and that's why I can't remove the vehicle from Yard Management.

  • Is there a way to find the number of downloads of music from itunes store?

    Hi,
    Is there any way to find the number of downloads of each music file available on itunes store. If not exact no of downloads but atleast a relative term to find the rank of the music track From any API
    Thanks
    Sandeep

    A: Is there a way to read the number of active sequence executions from the Engine?

    Scott,
    > One way of handling the issue of init once a set of instruments is to
    > create a new sequence file that has a sequence to init and a sequence
    > to close the instruments. Assuming that you always terminate a
    > sequence and do not abort them, you could add a ProcessSetup and
    > ProcessCleanup callback sequences to the client sequence file that
    > using these instruments. These callbacks are automatically called by
    > the process model in both the Single Pass and Test UUTs execution
    > entry points. The callback sequences could call the init and close
    > sequences for the hardware. In the hardware sequence file you could
    > reference count the number of execution that init and close by setting
    > the file globals in the sequence file to be shared across executions
    > and then add a numeric value that keeps track of references for the
    > instruments. The init sequence adds to the count, and the close
    > sequence subtracts from the count. The init sequence inits the HW if
    > the count is 0->1 and the close sequence closes the HW if the count is
    > 1->0.
    >
    > This is one of many ways in TestStand that this could be done, not to
    > mention that this could also be done in a similar way in a LabVIEW VI
    > or DLL directly.
    That sounds like it will work. I'll try adding a client count
    increment/decrement in the DLL initialize and terminate functions. This
    should essentially perform the same tasks as the callback scheme you mention
    above, no?
    The reason I didn't think the 'client counting' scheme would work initially
    was I mistakenly thought that the termination function would not get called
    under Terminate conditions. Since Terminate conditions happen a LOT during
    our initial debug of new UUT types, I didn't think that would be acceptable.
    I forgot that lacing the terminate funciton in a cleanup step group, I can
    force it to be called in Terminate conditions.
    > If you abort an execution then the reference counting idea above would
    > fail to decrement properly. That might b... [Show more]

    Read other 5 answers

Maybe you are looking for