Is it possible to use a PCI daq card (like the 6035e) on a laptop computer (Dell computer Inspiron 8100) via an adaptor or do I have to buy a PCMCI card?

Hello;
Even though you might find PCI/PCMCIA adaptors to adapt one bus type to the other, that doesn't guarantee the DAQ board will work on that setup.
I'm saying that because the NI-DAQ driver wasn't tested under such circunstance. Depending on how the driver of the adaptor is structured, the NI-DAQ driver for our DAQ devices might have difficulties on recognizing the DAQ device.
I think the safe choice is to purchase a PCMCIA DAQ card.
Hope this helps.
Filipe A.
Applications Engineer
National Instruments

Similar Messages

  • I use labview 8.0 and i can not run daqmx driver for pcmcia 6062e daq card

    i use labview 8.0 on window xp .when i installed a PCMCIA daq card 6062E, i could not run daqmx driver.It is fine to see that the traditional version is working well.When i install daq card sometimes it is working well with traditional driver  but mostly i see error on reading an analog input from PCMCIA daq device.An error called 'base adress' occures .I use last version of driver that is daqmx 8.0.1. and i have installed this correctly but again i could not  see any signal on the test panel for daq-mx driver.I don't know what is the problem.Also when i install PCMCIA daq card Please reply this message.I need your helps.
    Thanks

    Hello,
    Thanks for your reply.I will try to answer your questions.
    I have checked the Device Mananger and I have seen that the device is detected by Windows  XP.  For another question the card shows up under both NI-DAQmx Devices and Traditional NI-DAQ (Legacy) Devices consistently in the Measurement & Automation Explorer.I use a way that I reset the driver for traditional NI-DAQ in MAX,and then i reset the device for NI-DAQmx driver in MAX and again i tried to run the test panel of DAQmx driver but again i saw a wrong signal or noise signal on the test panel i could not see the sinusoidal signal that i connected. i do get the test panels to run with the card using the DAQmx driver,  But could not run the DAQ diagnostic utility.The error was as i specified below.
    03.05.2006 09:49:35
    Results saved to:  C:\Documents and Settings\serkan\Desktop\Diagnostic Results.txt
    Selected Device: Dev1
    Device Type: DAQCard-6062E
    Serial Number: 107509E
    Device Support: (PASS)
    NI-DAQmx Version: 8.0 (PASS)
    Device Reset: (FAIL)
    Error -50002 occurred at an unidentified location
    Possible reason(s):
    The specified device is not a valid device. The operation could not be completed as specified.
     ------ DIAGNOSTIC UTILITY ABORTED -----
    And for your last question i can say that i have used the DAQ card on other laptops.But the results were the same.İ hope to see your reply
    Thanks,
    Serkan Buhan
    Electrical-Elecronics Engineer
    Researcher
    TUBITAK-BILTEN

  • Can I develop a data acquisition app without the DAQ card installed?

    I'm new to LabView.
    I would like to build a simple data acquisition app (graphical display and logging). I would prefer to build this on my desktop, and then install/run it on a laptop.
    I'm not sure how to work this as the DAQ card and driver are not installed on my desktop. Is there a (hopefully) simple way to configure a data source in labview so that the app will automatically (or at least easily) connect to the existing driver?
    At the end of the day I don't want to install the complete dev system on my cheap little laptop just for this one application.
    TIA,
    Michael

    yes you can develop an application without having a daq card installed. You still will use the same functions in labVIEW. If you are using labVIEW 6.1 they are under the data acquisition palette in the block diagram. If you are using LV7 there are now two types of data acquisition functions. Traditional NI Daq (before lv 7) and new Daq MX. The daq functions are under the NI Measurements palette in LV7. If you are new to LV I suggest you use the daq assistant on the bottom of the palette. This will allow you to easily configure what you want, the drawback is that you will need to use this on the computer that has the card. So try the traditionaly nidaq functions. They will allow you to develop without the card. hope this helps.
    BJD1613
    Lead Test Tools Development Engineer
    Philips Respironics
    Certified LV Architect / Instructor

  • Can a DAQ card be connected to a PC's external PCMCIA card reader?PC

    What is involved to use a Flashmate PCMCIA card reader of PC with something like an AI-16XE-50 DAQ card? Will the card reader device driver work for this purpose?

    Hello;
    NI's DAQCards were tested to operate with the Native Microsoft Laptop Socket drivers only. Once you insert a third party device on your system, the NI-DAQ driver might or might not talk to the third party driver. That will be a trial and error process.
    Regards
    Filipe A.
    Applications Engineer
    National Instruments

  • LabView DAQ card programmin​g

    I have recently started using an NI USB-6211 DAQ card on my laptop. I have the driver software installed and the DAQ is working, but when in LabVIEW main package, I dont have any functions in measurement tab or express tab to use to control the DAQ . I would appreciate some help
    Solved!
    Go to Solution.

    That version of DAQmx is not supported with LabVIEW 2012.
    Try download the newest driver, version 9.7, http://joule.ni.com/nidu/cds/view/p/id/3811/lang/e​n

  • Data-acquisition with NI 6036E DAQ card & GPIB using an external trigger

    Hi all,
    I hope somebody could give me some help with the following and answer some questions:
    Simple system description:
    Labview 6.1
    PCI-GPIB card
    6036E DAQ card
    In my system, I am using an external analog trigger signal (A) for continuous data-acquisition. Characteristics of the analog trigger signal (A) are: ~40 Hz, signal height +1.48V, triggered by rising edge (the analog trigger signal (A) could be changed to a TTL signal). Each data-acquisition is done within ~1.0 ms after the rising edge of the trigger pulse. The timing of the data-acquisition and analyzing procedure is controlled by execution in a sequence structure placed in a loop.
    Now, I connected a power meter to the system, to measure the laser power during the data-acquisition. The power meter has two options to provide the laser power data:
    a) via analog signal output (voltage corresponds to laser power in watts)
    b) via GPIB (direct output reading of laser power in watts).
    Problem:
    During a certain point in my data-acquisition sequence structure (defined by a frame), I want to use the next occuring analog trigger signal (A) to acquire 1 value from the power meter.
    How do I do this in Labview programming for the following two situations?
    a) If I connect the analog output from the power meter to an analog input channel of the 6036E DAQ card. The analog trigger (A) would be connected to a second analog input channel (In case the analog trigger signal (A) is changed to a TTL signal it would be connected to the PFI0/Trig input pin on the DAQ card).
    b) If I use the GPIB connection of the power meter. The analog trigger (A) would be connected to a second analog input channel (In case the analog trigger signal (A) is changed to a TTL signal it would be connected to the PFI0/Trig input pin on the DAQ card).
    An other possibility would be to trigger the power meter directly, so it outputs constantly power meter values at ~40 Hz. How could I than acquire 1 power meter value (at a certain time im my sequence structure) via analog input at DAQ card or GPIB?
    Additional questions:
    How do I configure the PFI0/Trig pin on the 6036E DAQ board individually as an INPUT?
    How do I use an analog trigger signal (A) as counting signal for a loop, or as an activation signal for a sequence structure which includes GPIB commands?
    It would be very nice if somebody could give me some help.
    Kind regards,
    beam

    Hi beam,
    I just want to verify that I understand your situation correctly:
    An external trigger signal (A) is wired to one of your input channels (e.g. CH0) to trigger data acquisition of a second channel (e.g. CH1). Your power meter is connected to an analog input channel, which you would like to trigger with a certain rising edge at some of your sequence structure.
    Problem:
    During a certain point in my data-acquisition sequence structure (defined by a frame), I want to use the next occuring analog trigger signal (A) to acquire 1 value from the power meter.
    How do I do this in Labview programming for the following two situations?
    a) If I connect the analog output from the power meter to an analog input channel of the 6036E DAQ card. The analog trigger (A) would be connected to a second analog input channel (In case the analog trigger signal (A) is changed to a TTL signal it would be connected to the PFI0/Trig input pin on the DAQ card).
    If a task has been configured to acquire signal from one analog channel, it's not possible to run a second analog input task or to add a second channel on the fly. You had mentioned that it's possible to read from the instrument through GPIB. Is it possible to perform a software trigger such that at a certain frame of your structure, when the trigger signal A reaches voltage "x", a GPIB command is written to your power meter to query a measurement reading?
    Additional questions:
    How do I configure the PFI0/Trig pin on the 6036E DAQ board individually as an INPUT?
    You do not need to explicitly configure the PFI0 line as an input. If you want to use it as an input such that it acts as an analog trigger, simply wire the trigger signal to this pin. When configuring the trigger in your software, specify PFI0 as the trigger source.
    How do I use an analog trigger signal (A) as counting signal for a loop, or as an activation signal for a sequence structure which includes GPIB commands?
    You can try using the Limit VI to find out when the trigger signal reaches a certain level, and count how many times this level is reached. Similarly, you can use this as the condition to execute GPIB commands.
    Hope this helps,
    Lesley

  • Can I use ARM LM3S8962 like a DAQ card?

    I have the ARM embedded software and have used it to write some programs that run on the LM3S8962.  What I'm wondering is if I can have a program that runs on the PC that "talks" to the ARM board occasionally to query the inputs or control outputs.  If it is possible, how would I do that?

    You absolutely can use an ARM LM3S8962 like a DAQ card, the only restraints you have are how fast the microprocessor can run and the limited amounts of AI you have available on the Luminary board. you can simply add an AI elemental I/O node to your project and wire your transducer to the luminary board. You then can take the data from the microcontroller and send it to the Host PC through a network published shared variable. There are a couple of tricks to this that may not be completely evident. I have included two links that I think will help you get to where you want to be. The first is setp by step how to connect an accelerometer to teh ARM board, but you can modify it for your own transducer.
    http://decibel.ni.com/content/docs/DOC-9614
    The second is hwo to use network published shared variables on an ARM board. I hope this helps!
    http://digital.ni.com/public.nsf/allkb/6E50B28DDC61C0E68625767400805AA0
    Scott W
    National Instruments
    Applications Engineer

  • How to acquire data from 2 chs of the same DAQ card at different sampling rate

    I am using single DAQ card (either 6013 or 6014) in my system i want to acquire data from 2 (or more) channels with following requirements
    1. sampling rate of each channel should be independant of each other (say one is 20 Hz and other is 15 kHz)
    2. data from all the channels should be acquired simultaneously.
    3. coding must be done using DAQmx VIs
    I have tried out following things
    1. I created separate task for each channel: i found out that two tasks can not run simultaneously even though the channels are different
    2. I tried out single task with two channels included in it. and i used 'channels to Read' property to determine from which ch. i want to acquire data: this method works fine if the sampling rates are same. but if i change the sampling rate of one channel it gets reflected in other channels as well.
    can somebody help me out to solve this problem.
    i will appreciate if somebody can post the sample code as my deadline is approaching
    Tushar Jambhekar
    [email protected]
    Jambhekar Automation Solutions
    LabVIEW Consultancy, LabVIEW Training
    Rent a LabVIEW Developer, My Blog

    Hi Dennis Knutson
    Thanks for your suggestion.
    Tushar Jambhekar
    [email protected]
    Jambhekar Automation Solutions
    LabVIEW Consultancy, LabVIEW Training
    Rent a LabVIEW Developer, My Blog

  • How do I use two DAQ cards in one Labview code? Current I'm getting error " error 200558 occurred at DAQmx Create Channel.vi. One task cann't contain multiple independent devices". Can someone help me?

    The two DAQ cards are NI PCI-6070E & NI PCI-6052E. The Labview I'm using is labview 7 Express and the Window system is Window XP. I'm using NI SCXI-1000 chasis and SCXI-1102 & 1102B two modules plus a feedthrough SCXI-1180. 1102 is connected through SCXI-1349 cable to DAQ card 6052E while 1102B is connected through SCXI-1349 cable to DAQ card 6070E. SCXI-1180 is connected to 6070E through SCXI-1349 adaptor on the back of 1102B.

    Sarah, thank you for replying my question. It seems that I'm making progress everyday (smile). I'm able to run the test using both daq cards in my code now. But as I'm moving forward, I'm getting new questions too. How do I use one STOP button to control both tasks and how can I save data into one single file?
    I attached my code here hoping you can get the specifics on my application by looking at the code. Thanks very much!
    Thanks.
    Attachments:
    DAQmx_Task_Example_plus_voltage_2.vi ‏416 KB

  • How can I create software start and stop trigger in LabView using 6023E series DAQ card? I don't want to use the external trigger.

    I am using 6023E DAQ card to collect the signals, such as AE, Force, Torque from the machine. I want to collect only some part of signal for example between start triger and stop trigger. I'd like to know how I can creat those triggers in LabView from one of the channels that I am acquiring at the same time. I found one or two library file that is only for start trigger. I know that this is availabe in some of DIAdem functions. Please let me know if you have done some example for this requirement.

    If you are wanting to create a software trigger based on an analog input voltage in LabVIEW, there are several options. One suggestion would be to compare the voltage values from one input channel to a number within a loop. If the input voltage crosses that threshold (is greater than the number), have a case statement that will acquire data from the other channels. This would simulate a software start trigger in LabVIEW.

  • How to structure the DMA buffer for PXie 6341 DAQ card for analog output with different frequencies on each channel

    I'm using the MHDDK for analog out/in with the PXIe 6341 DAQ card.
    The examples, e.g. aoex5, show a single Timer  (outTimerHelper::loadUI method), but the example shows DMA data loaded with the same vector size.
    There is a comment in the outTimerHelper:rogramUpdateCount call which implies that different buffer sizes per channel can be used.
       (the comment is: Switching between different buffer sizes will not be used)
    Does anyone know what the format of the DMA buffer should be for data for multiple channels with different frequencies ?
    For example, say we want a0 with a 1Khz Sine wave and a1 with a 1.5Khz sine wave.  What does the DMA buffer look like ?
    With the same frequency for each channel, the data is interleaved, e.g.  (ao0#0, ao1#0; ao0#1, ao1#1, ...), but when the frequencies for each channel is different, what does the buffer look like ?

    Hello Kenstern,
    The data is always interleaved because each card only has a single timing engine for each subsystem.
    For AO you must specify the number of samples that AO will output. You also specify the number of channels. Because there is only one timing engine for AO, each AO will channel will get updated at the same time tick of the update clock. The data will be arranged interleaved exactly as the example shows because each AO channel needs data to output at each tick of the update clock. The data itself can change based on the frequency you want to output.
    kenstern wrote:
    For example, say we want a0 with a 1Khz Sine wave and a1 with a 1.5Khz sine wave.  What does the DMA buffer look like ?
    With the same frequency for each channel, the data is interleaved, e.g.  (ao0#0, ao1#0; ao0#1, ao1#1, ...), but when the frequencies for each channel is different, what does the buffer look like ?
    In your example, you need to come up with an update rate that works for both waveforms (1 KHz and 1.5 KHz sine waves). To get a good representation of a sine wave, you need to update more than 10x as fast as your fastest frequency...I would recommend 100x if possible.
    Update Frequency: 150 KHz
    Channels: 2
    Then you create buffers that include full cycles of each waveform you want to output based on the update frequency. These buffers must also be the same size.
    Buffer 1: Contains data for the 1 KHz sine wave, 300 points, 2 sine wave cycles
    Buffer 2: Contains data for the 1.5 KHz sine wave, 300 points, 3 sine wave cycles
    You then interleave them as before. When the data is run through the ADC, they are outputting different sine waves even though the AO channels are updating at the same rate.

  • I would like to know: what sort of DAQ card, I have to use with LabWindows, to have datas from 3 sensors?

    If you have some references or internet sites, please, answer me.
    A French guy.

    Most any of National Instrument's DAQ boards will do this. We provide a tool to help you pick which DAQ card is best for your application called DAQ Designer. You can access DAQ Designer online at: http://www.ni.com/daq/ddonline.htm.
    Best Regards,
    Chris Matthews
    Measurement Studio Support Manager

  • DAQ card works with NIDAQ test panel but not with VB app/Component works

    I am seeing this problem with 2 different DAQ cards. The card works fine with the NIDAQ test panel, but acts like the return lead is lifted with my VB app. The plotted signal appears to be little more than noise. Channel scan is internally triggered; that apparently works fine. The VB app is running in this configuration successfully in other areas, and I fixed this problem once by swapping cards. Currently, I lack a spare, as my "spare" is showing the same symptoms. Any helpful hints?
    Card type: AT-AI-16XE-10
    Configuration: Double-ended input, +/-10V range
    Running: VB6, NIDAQ 6.1, ComponentWorks Std. 2.0.1, Windows NT 4.0 SP5

    I upgraded to NI-DAQ 6.8.1 (with patch), but no joy. The upgrade went smoothly, the card was recognized and I was able to set the resources without a problem. The test panel works fine looking at the actual signal on the target system: slowly varying DC between 0-5 V or so. My app works fine also, except that it behaves as though the A/D is not connected to anything: noise between .05-.1 V or so. I swapped DAQ cards between the test system and my development system. The problem appears to be in the test system, not on the card. Another test system, identical except for (now) the version of NI-DAQ, works fine. I'm stumped!
    BTW, why are there 3 DMA channels listed in the configuration for this DAQ? Do all 3 need to be assigned? I've run some systems
    for years with only the first 2 assigned.

  • How to generate a pulse waveform 90 deg phas shifted with respect to a pulse generated using a counter in PXI 6070E daq card ?

    Hi
    I ma using 6070E daq. I am generating a infinite pulse train using one of the counters. I want to generate another pulse train which should 90 degress phase shifted with respect to the previsously generated pulse. How to implement this using the counters in the DAQ card.

    Hi Gopal,
    1) yes the frequency generator is programmable. You have 2 timbebases (10MHz and 100kHz) and you can divide down by any integer between 1-16. Those are the only frequencies you can use.
    2) The way counters work is that you can apply a gate signal to the counter which will cutoff the output. Therefore, you can have a second counter generating a pulse train of an equivalent frequency to the frequency generator (fout) but you don't want it to start immediately. You want it to start only after a short delay (equivalent to a 90d phase). Therefore, you need to "gate" or prevent the output on this counter for that small delay period of time. The way you can do this is by using a second counter to create a delayed pulse. You would
    connect the output of that counter to the gate of your pulse train function. That way, during the delay period of the pulse, you won't be outputing your pulse train yet. When the pulse (high-time) of your pulse reaches the gate, then your pulse train will start generating its pulse train (which is consequently delayed by the amount of delay used in the single delayed pulse counter). Since you don't want your pulse to go back low, you will have to turn off or clear your pulse counter while it is high. That way the signal on the gate will remain high forever.
    Your better solution is to use a PCI-660x card to perform this action. You will have more counters which will give you a greater range of frequencies to choose from and you will have more accurate timing of the signals.
    Anyway, hope that clears things up. Have a good day.
    Ron

  • I am looking to control a 4-way hydraulic solenoid valve. Do I need a PID control toolset, or can i control the system through my 16E4 daq card and scxi chasis

    I am looking to control a 4-way hydraulic solenoid valve. Do I need a PID control toolset, or can i control the system through my 16E4 daq card and scxi chasis

    I think you're asking 2 different questions.
    The PID control toolset is for using PID loops for control; it's just software.
    The DAQ card and scxi chassis are hardware. If you have the appropriate signal conditioning cards in your chassis to control/monitor your solenoid valve, then you can run a PID loop.
    I believe the simple answer is: the PID control toolset is the best way to do control, but there are simple PID VI's (even on this website) that you can download and use for simple control.
    Mark

Maybe you are looking for

  • Writing two linked objects (obj1 is linked to obj2)?

    writing two linked objects (obj1 is linked to obj2) Approach A: ObjectOutputStream o = new ... o.writeObject(obj1); o.writeObject(obj2); o.close(); Approach B: ObjectOutputStream o = new ... o.writeObject(obj1); o.close(); o = new ... o.writeObject(o

  • How do i check how many times ive acticated CC

    hi i bought adobe cc and downloaded it onto my laptop but then i got some problems saying that it was only the trial, so i installed it on my brothers laptop aswell so i could use it on that. now  i am thinking of buying another laptop but i want to

  • How to assign status profile to Business partner

    Hi Gurus, in sap crm 7.0 web ui i want to restrict particular user group to only" see" accounts it means only  "display"  view this we can achieve through status profile but how it is configured i don't know...can somebody help me understand it. Than

  • Outlook not syncing with iCal after Lion Upgrade

    I updated to Lion, so I could more easily sync our family's calendars and contacts in Outlook to our iPhones/iPods via iCloud.  Now that I have done that, Outlook no longer syncs to iCal/Address Book and then there is the internal Microsoft issue.  H

  • Raw material -scrap-against production order

    Hi all,           I withdrawn 10 qty of raw material for production order using mvt type :261. Due to some wrong machine Operation  2 qties of the Raw material is become unusable(scrap). I want to return this 2 qty of raw material to warehouse. what