List UEFI Bios Settings Using PowerShell

Create a file containing the uefi bios settings with values on your desktop by running this PowerShell script:
gwmi -class Lenovo_BiosSetting -namespace root\wmi  | select currentsetting | where Currentsetting -ne "" |
select @{label = "Name"; expression = {$_.currentsetting.split(",")[0]}}, @{label = "Value"; expression = {$_.currentsetting.split(",")[1]}} |
Sort Name | ft -auto > $env:userprofile\desktop\"UEFI BIOS Settings.txt"

Hi jasgud_RETSD -  Have you tried using PSEXEC?   PSExec lets you run items using the system account.  You can download psexec from the Microsoft page for Sys Internals.   Command - psexec \\localhost -s -h powershell.exe -executionPolicy bypass -Noninteractive -Noprofile -file %script%.ps1 -password %password% -file LockBIOSSetting-enable.txt -s = Run as System -h = no profile-accepteula - accepts eula I ran the your command (changing the powershell name) and confirmed you can call powershell.exe and use powershell flags (nointeractive -noprofile).   Once this to keep in mind when using psexec - the command being called (powershell.exe in this case) must be located in a directory referenced in path variables.  psexc can be executed multiple clients at once by specifying a txt file with the names of the clients you wish to target.  Multiple Clients PSEXEC @domainclients.txt -s -h powershell.exe -executionPolicy bypass -Noninteractive -Noprofile -file %script%.ps1 -password %password% -file LockBIOSSetting-enable.txt I am more insterested in getting the bios settings setup for deployments   Thanks Jeff Ragucci  

Similar Messages

  • X220 - Can't change UEFI/BIOS settings anymore, locked out of update

    Since a few weeks my X220 is not able to make any changes to the  UEFI/BIOS settings. When trying to do so either any changes get silently ignored or I get one of the following error message while trying to save. 
    Security - Failed to save storage: Setup. Status: 0x9
    Security - Failed to save storage: PwdStatusVar. Status: 0x9
    Security - Failed to save storage: LocalSecurityVars. Status: 0x9
    Didn't find anything on those errors here or on the web, unfortunately.
    This is with UEFI 1.19, unfortunately this problem even prevents me from upgrading to the latest release (this is a linux-only system, so no Windows-tools, also I had UEFI-only enabled in the settings when this happened, so the Update-CD won't boot). Also I had some parts of the hardware disabled when this started to appear, so can't reenable them anymore, which is pretty bad as you might imagine.
    Three notes:
    *) there is one exception to not being able to save, I can successfully set (and remove) a supervisor password, but that's all
    *) After the UEFI tries to save the settings there's a hang for 2-3 seconds, don't know if this is related.
    *) The time from pressing the power button until the X220 reaches the boot loader is significantly longer since this effect showed up
    Anyone got a clue what these errors are actually about? I thought about pulling the BIOS/UEFI battery and trying to force a reset of the settings that way. Is this safe or a bad idea?
    Solved!
    Go to Solution.

    I think you should call the support team in your country and request service:
    http://support.lenovo.com/en_US/research/hints-or-tips/detail.page?LegacyDocID=MIGR-4HWSE3
    Otherwise, if you're comfortable removing the keyboard and palmrest, you could try to disconnect and reconnect the CMOS battery.  But there's no guarantee that this will solve the problem, which I why I think the better idea is to call the support team.

  • Application not listed in iOS- Settings- "Use Cellular data for"

    Hello,
    When i install the IPA of my application, it is not listed in the "Use Cellular data for" list in Cellular data Settings. I would like to know how to add my application to this list.
    Also, is it possible to get the Enabled/Disabled status of the my application if listed in the above list.

    No, but you could turn off Updates under Automatic Downloads in Settings>iTunes & App Store, then update them manually when you're connected to wifi.

  • The code feature and a list of BIOS settings

    I saw a user on this board post their entire BIOS screen and all of it's settings. How did they do that? They never got back to me with an answer?

    digital Camera  
    I must admit i was suprised & suitably impressed when I 1st saw it, Thought it was a Dos utility or something
    It's sweet i've used it now it makes things a lot easier.

  • Set Advertisement settings using powershell

    Hi,
    I need to change multiple advertisements with a powershell script. All advertisements have a mandatory assignment configured, and I need to check the "Ignore maintenance windows" and set the Rerun Behavior as "Always rerun". I created
    a powershell script that read the advertisements names from a file and change each one. The problem is: When I run the script, the mandatory assignment is removed from advertisement! Any ideas how to fix it?
    #Get Advertisement name from txt file
    $Source = Get-Content c:\temp\AdvertName.txt
    #Set counter to 0
    $Count = 0
    #For each advertisement in source file, change Properties as needed and increment counting
    Foreach ($AdvertName in $Source)
    #Connect to SCCM server using WMI and filter advertisement by name present in source file
    $Advert = Get-WmiObject -ComputerName SCCMSERVER -Namespace "root\sms\site_SCCM" -class SMS_Advertisement -Filter "AdvertisementName like '$AdvertName'"
    #Set AdvertFlag (OVERRIDE_SERVICE_WINDOWS+DONOT_FALLBACK+NO_DISPLAY+ONSLOWNET)
    $Advert.AdvertFlag = 101842944
    #Set RemoteClientFlag (DOWNLOAD_FROM_LOCAL_DISPPOINT+DOWNLOAD_FROM_REMOTE_DISPPOINT+RERUN_ALWAYS)
    $Advert.RemoteClientFlags = 2128
    #Apply Advertisment modification
    $Advert.put()
    #Increment counting by 1
    $Count ++
    #Write message to user with total  advertisements
    Write-Host "Processed Advertisements: $Count"

    You should use UPN not ALIAS
    Set-SPOSiteGroup -Site https://contoso.sharepoint.com -Identity "NewGroup" -Owner <UPN>
    Regards Chen V [MCTS SharePoint 2010]

  • Set the "Schedule compliance evaluation" schedule in the default client agent settings (compliance settings) using powershell?

    I am having trouble figuring this out.  using the Set-CMClientSettings is it possible to modify the "Compliance Settings" "Schedule compliance evaluation" schedule.  The default is every 7 days and I want to be able to modify
    that.
    Thanks
    Eric

    I just checked and I don't see a way to do this even with the R2 CU1 cmdlets. I would recommend filing a feedback on Connect regarding this here:
    https://connect.microsoft.com/ConfigurationManagervnext
    Check out my Configuration Manager blog at http://aka.ms/ameltzer

  • R7770-PMD1GD5 GOP UEFI BIOS to use WIN8 and WIN8.1 boot feature

    Hello!
    I would like to use the Win 8.1 boot feature, so can I get a new BIOS to my videocard?
    The original ROM is here:
    <iframe src="https://skydrive.live.com/embed?cid=8D31B093A6C5CB21&resid=8D31B093A6C5CB21%211949&authkey=AGlpnJb2B1gUKtY" width="98" height="120" frameborder="0" scrolling="no"></iframe>
    S/N:
    602-V271-070B1303042303
    The sticker also has the following numbers:
    912-V271-014
    R7770-PMD1GD5
    And I also have another question. Can I use Atiflash on 64bit Win8.1?
    Thank you

    Use >>this<<
    Don't try flashing in Windows.
    Decompress the provided .rar archive with Winrar: http://www.rarlab.com/download.htm
    Create a bootable usb stick (https://forum-en.msi.com/index.php?topic=165175.0).
    Then unpack the previously provided archive (qd3.rar) and put the included file (TV271MH.150) on that stick.
    Rename TV271MH.150 to 150.rom. Put the atiflash.exe also included in the archive provided on the USB stick too. Now boot from the stick.
    Type atiflash -p -f -noaper 0 150.rom [ENTER] and let it flash the vbios.

  • Forum Code Feature used to display BIOS settings

    The code feature on the board was used by a user in the overclocking forum to display his entire list of BIOS settings. Just as my luck would have it, I cannot find this post. I was wondering if anyone knew how to post there BIOS settings using the code feature and better yet, how did this guy figure it out without anyone telling him?
    Code: [Select]
    BIOS SETTINGS IN HERE

    I finally found the link! HOW DID THIS GUY DO THIS?
    https://forum-en.msi.com/index.php?topic=71446.0

  • P7N diamond bios settings listing, saving, and loading

    I think I know the answer to both of these  questions, but what the hell maybe the obvious isn't always the case and a yes to either would be really cool so
    Is there any way to list my bios settings, you know like a simple cat or tostring() so I can have a cheat sheet
    if I save my bios settings in user settings, can I load those into a new version? (I'm thinking they're erased with the new flash, it wouldn't work, or it would flash back

    Allow me one last comment in this thread because I think Karlbad did not get the point of my reply:
    Creating a tool to readout parts of the CMOS Memory (where the settings are stored) is not a problem.  Here is the data a simple BASIC Program puts outs:
    The tricky point is to relate each and every one of these numbers to their particular function within the parameters of my particular BIOS Setup structure.  To translate these numbers back to the actual options in the BIOS Setup mask is a possible task.  However, it takes many, many hours.  This in itself is not a problem either: the crucial point is that this needs to be done for any particular BIOS Version that is looked at. 
    If this relational problem is considered, it easy to understand that pen&paper and/or a digital camera are better ways to get the job done.  They do not take hours of programming which would need to be repeated for any particular BIOS Version.  And because of that, such tools are a complete waste of time, a complete waste of energy and ambition and also a pointless activity.  And (to take the arguement one step farther) that is precisely why you will not be able to find anything useful using Google.  Useful tools for this kind of task don't exist, because they are pointless.
    Now, if that is to hard to understand, I don't know what to say.  Reacting with swearing is probably the only possible response.  However, it does not rule out the fact that your memory in conjunction with a pen and a piece of paper and/or a camera is the best option here.
    Quote
    My 1.2 bios does have an option to save settings
    Yes, but not to a file external to the BIOS and even if, you would get a similar sequence of raw data as you can see in the screenshot above.
    Your best options under the bottom line:
    - use your memory
    - use pen & paper
    - use a camera
    --> Problem solved. 

  • How to export Listitems in sharepoint 2010 using powershell

    I am able to export all items in sharepoint list by below command in powershell
    Export-SPWeb -Identity
    "http://myurl.com" -   path
    "C:\Export\Lists\Announcements.cmp" -ItemUrl
    "/Lists/Announcements/AllItems.aspx" -Force
    My list is having huge data in production I want to export only 10 items from the list using powershell. Is there any command to export only certain items.
    I want to filter the Items and export only certain set of items using Export command.
    Rajendra

    Hi all,
    To export a list you can try: 
    Export data from SharePoint 2010 List using Management Shell: http://www.experts-exchange.com/OS/Microsoft_Operating_Systems/Server/MS-SharePoint/A_9182-Export-data-from-SharePoint-2010-List-using-Management-Shell.html
    Export SharePoint 2010 List to Excel with PowerShell: http://iwillsharemypoint.blogspot.com.es/2011/02/export-sharepoint-2010-list-to-excel.html
    Export SharePoint List Items to CSV using PowerShell: http://www.sharepointdiary.com/2013/04/export-sharepoint-list-items-to-csv-using-powershell.html
    If a post answers your question, please click Mark As Answer on that post and
    Vote as Helpful

  • UEFI Bios for Pavilion a6750t?

    Hi,
    I have a Pavilion a6750t with Windows 7 64-bit.  I am trying to use a 3TB hard drive for my main drive.  I seem to need GPT partitioning with UEFI bios to use all 3TB as my C drive.  Does that sound right?  Right now, it is recognizing about 2TB after I installed Intel Rapid Storage Technology.  Is UEFI bios available for this motherboard?  How would I get it, or how would I know if I have it correctly installed?
    Thanks fo any help.

    Use the attached.
    Decompress the provided .rar archive with Winrar: http://www.rarlab.com/download.htm
    Then flash the included file with Nvflash for dos: http://www.guru3d.com/files_details/nvflash_download.html
    To do so rename the included file to .rom and create a dos bootstick (https://forum-en.msi.com/index.php?topic=165175.0)
    Put nvflash and the vbios file on it and boot from the stick. Then type nvflash -4 -5 -6 gop.rom (if renamed vbios that way) and hit enter. Confirm the questions and let the tool flash.

  • Feature not appearing in site collection features list using powershell

    I created a custom web part solution which adds a custom web part to the web part gallery - simple.
    I did this on my dev server and used Visual Studio's deploy button to deploy it, and it all worked. The solution was added to the Solution Store, my feature was now in the Site Collection features list and automatically activated. So I checked my web part
    gallery and it was there as well... great.
    Now I'm ready to migrate my simple web part to my Prod server. I managed to use WSP builder to build my wsp. So now i have my wsp file.
    I used Powershell to add my solution to my Prod server, that worked. So I ran the Install-SPSolution command and looking at the logs, it all seemed to install fine. Here are the commands I used: 
    Add-SPSolution “E:\Deployment WSPs\HRFeedbackForm.wsp“
    Install-SPSolution -Identity "HRFeedbackForm.wsp" -GACDeployment
    However, when I go to my Site Collection Features, I can't see my feature. There is nothing in my 14 hive either and as far as I can see, and there are no errors in my log files.
    So what have I done wrong?
    So I tested adding and deploying the same solution on my dev box using Powershell and I had the same problem as what I've experienced on my Prod server. So what's the difference between deploying solutions via Visual Studio Deploy and using those powershell
    commands??? Is there something else I'm meant to change, somewhere?
    I hope someone can shed some light on this issue.
    Danielle :)

    Hi,
    I wonder whether you have to populate this web part by force in your web part gallery.
    For this, go to your Site's Home page. Then...
    Site Action > Site Settings > Galleries > Web Parts
    From here...
    Under Library Tools go to Documents Tab > Click on New Documents > The New Web Parts popup will open
    Here search for your web part. If you find it, select it and Check "Overwrite if file already exisists" and click on Populate Gallery.
    If the above does not work, I am stumped too. I will be curious what other members of the community have to add.
    Thanks, Soumya | MCITP, SharePoint 2010
    Omg it was there and i've added it to the web parts library and it works.... that was soooo strange.
    Thanks Soumya :)
    Can you explain at all why the web part has been added to the web part gallery, but the feature doesn't appear under site collection features?
    Danielle :)

  • Installing Windows 8 using WDS on devices that use UEFI BIOS

    Hi all, sorry for the word wall.
    I am currently planning a deployment of Windows 8.1 Upgrade 1 on Toshiba Z10T's which I will be deploying using WDS, which is running on Windows Server 2012 R2.
    The Toshiba Z10T device in question is quite handy as it can switching between legacy CSM BIOS and UEFI BIOS.
    The devices are shipped out of the box with UEFI BIOS on, and obviously we would like to be able to just un-box & image them, however we have constant issues when trying to PXE boot devices with UEFI BIOS, and the only way I can get them to PXE boot
    is by switching over to legacy CSM BIOS.
    From what I have read from other forums on the internet, UEFI & WDS don't get on that well - so what I was wondering is this-
    We currently have SCCM 2012- I was wondering would we have more success booting to a UEFI BIOS if I used SCCM & MDT or will I still encounter the same issues?  Is it the PXE client in UEFI that is at fault?
    Problems that we encounter when we use UEFI to PXE boot are- Drivers not there to get into to the boot image; if we can get them to image, devices will not join to the domain; devices will image but not install any drivers.
    Thanks for reading this word wall.

    PXE itself doesn't use/need any drivers at all - it's the post-boot (boot image), and the full OS (install image) which need the drivers.
    PXE is totally contained within ROM, and that ROM will download the NBP (for non-UEFI this is typically wdsnbp.com)(for UEFI this is typically bootmgfw.efi).
    In a ConfigMgr (or MDT) scenario, the NBP then downloads boot.sdi, boot.wim(WinPE) and then install.wim(Full OS).
    Both boot.wim, and install.wim, need to have the correct network card drivers and also the correct storage controller drivers installed.
    This is how Windows deployment via PXE works (it's most often the lack of the correct drivers, at the required stage/phase, which causes grief)
    [background]
    Although we have a small number of Z10Ta and Z10Tb devices in my organisation, we are still using the factory image on them, so I haven't spent the time to incorporate them into our ConfigMgr OSD (PXE) supported-list yet.
    We are just starting our journey towards UEFI-boot. We are using MDT UFD bootable media for our lab and it's working fine for UEFI and Win8.1/64bit, on various devices (although not tried the Z10Ta/b). Am nearly finished moving that all into ConfigMgr, to
    then begin testing it all with PXE.
    Don
    (Please take a moment to "Vote as Helpful" and/or "Mark as Answer", where applicable.
    This helps the community, keeps the forums tidy, and recognises useful contributions. Thanks!)

  • PowerShell and WMI to modify BIOS settings

    Hello Scripting Guys!!
    I am trying to change BIOS settings for HP DC8300 Desktop using PowerShell /WMI. By going though the HP Client Management Interface technical white paper from HP, which describes the class and method to accomplish this task, and research. I came to know about
    the following command.
    $AfterPower = gwmi -computername [PCName] -Namespace root/hp/instrumentedBIOS -Class HP_BIOSSettingInterface
    $AfterPower.SetBIOSSetting ('After Power Loss', 'Off', 'password' )
    The command runs successfully, however it displays the following output with the return code 6
    __GENUS : 2
    __CLASS : __PARAMETERS
    __SUPERCLASS :
    __DYNASTY : __PARAMETERS
    __RELPATH :
    __PROPERTY_COUNT : 1
    __DERIVATION : {}
    __SERVER :
    __NAMESPACE :
    __PATH :
    Return : 6
    The Return Code  6 is Access Denied
    This happens even when I run this script targeting my local machine. I am runing the PoweShell as Administrator  also checked the WMIControl security setting  from "Services and Application"
    under Computer Management Concole which is in order.
    Any help would be highly appreciated.
    Cheers!!!!
    Faraz Amjad

    Hi Guys,
    After spending a complete day and going through different forums and HP's documentation (HP CMI technical whitepaper), I finally got this working by the following script. 
    $AfterPowerr= Get-WmiObject -computername "PCNAME" -Namespace root/hp/instrumentedBIOS
    -Class HP_BIOSSettingInterface 
    $AfterPower.SetBIOSSetting('After Power', 'On ' , '<utf-16/> Password')
    Password will be your current password and in plain text.
    Sharing is Caring
    Faraz Amjad

  • How to add a certificate to IIS global "Server Certificates" list using PowerShell?

    Hi, been surfing the web for an example on how to add a certificate to the "global" IIS "Server Certificates" list using PowerShell but to no luck. I already have code in place on how to tie / associate a specific website with a specific cert but not how
    to add the new .cer file using the "Complete Certificate Request..." wizard using PowerShell.... I dont expect the final code to become published but if someone had an idea on howto integrate / get an entry point on where to interact between the "Server Certificate"
    list in IIS and POSH I would be super happy! :|
    I am runnign IIS on a Windows 2008R2 x64 Standard Edition if that helps..... of course, I would saddle for an CLI if there is no other way, but POSH is of course the way to go! :)
    Thanks for the help in advance guys, take care!
    br4tt3

    Hi and thanks for the suggestions!
    Although it comes close, the suggested code example points on howto import / incorporate .pfx files - I am getting fed by .cer files which I need to add into the IIS console using POSH.
    I tried explore the IIS.CertObj object but was not able to work out if this one could be used for importing / adding .cer files into IIS! However, launching the following command from a POSH console with Import-Module Webadministration already
    loaded into that shell;
    $certMgr = New-Object -ComObject IIS.CertObj returns the following error message:
    New-Object : Cannot load COM type IIS.CertObj
    From an IIS perspective I have the following components installed;
    [X] Web Server (IIS)                                    Web-Server
        [X] Web Server                                      Web-WebServer
            [ ] Common HTTP Features                        Web-Common-Http
                [ ] Static Content                          Web-Static-Content
                [ ] Default Document                        Web-Default-Doc
                [ ] Directory Browsing                      Web-Dir-Browsing
                [ ] HTTP Errors                             Web-Http-Errors
                [ ] HTTP Redirection                        Web-Http-Redirect
                [ ] WebDAV Publishing                       Web-DAV-Publishing
            [X] Application Development                     Web-App-Dev
                [ ] ASP.NET                                
    Web-Asp-Net
                [X] .NET Extensibility                      Web-Net-Ext
                [ ] ASP                                    
    Web-ASP
                [ ] CGI                                    
    Web-CGI
                [ ] ISAPI Extensions                        Web-ISAPI-Ext
                [ ] ISAPI Filters                           Web-ISAPI-Filter
                [ ] Server Side Includes                    Web-Includes
            [ ] Health and Diagnostics                      Web-Health
                [ ] HTTP Logging                            Web-Http-Logging
                [ ] Logging Tools                           Web-Log-Libraries
                [ ] Request Monitor                         Web-Request-Monitor
                [ ] Tracing                                
    Web-Http-Tracing
                [ ] Custom Logging                          Web-Custom-Logging
                [ ] ODBC Logging                            Web-ODBC-Logging
            [X] Security                                   
    Web-Security
                [ ] Basic Authentication                    Web-Basic-Auth
                [ ] Windows Authentication                  Web-Windows-Auth
                [ ] Digest Authentication                   Web-Digest-Auth
                [ ] Client Certificate Mapping Authentic... Web-Client-Auth
                [ ] IIS Client Certificate Mapping Authe... Web-Cert-Auth
                [ ] URL Authorization                       Web-Url-Auth
                [X] Request Filtering                       Web-Filtering
                [ ] IP and Domain Restrictions              Web-IP-Security
            [ ] Performance                                 Web-Performance
                [ ] Static Content Compression              Web-Stat-Compression
                [ ] Dynamic Content Compression             Web-Dyn-Compression
        [X] Management Tools                                Web-Mgmt-Tools
            [X] IIS Management Console                      Web-Mgmt-Console
            [X] IIS Management Scripts and Tools            Web-Scripting-Tools
            [ ] Management Service                          Web-Mgmt-Service
            [ ] IIS 6 Management Compatibility              Web-Mgmt-Compat
                [ ] IIS 6 Metabase Compatibility            Web-Metabase
                [ ] IIS 6 WMI Compatibility                 Web-WMI
                [ ] IIS 6 Scripting Tools                   Web-Lgcy-Scripting
                [ ] IIS 6 Management Console                Web-Lgcy-Mgmt-Console
        [X] FTP Server                                      Web-Ftp-Server
            [X] FTP Service                                 Web-Ftp-Service
            [X] FTP Extensibility                           Web-Ftp-Ext
        [ ] IIS Hostable Web Core                           Web-WHC
    More or less the one thing that I am trying to get up and running is an automated FTPS solution - I just use the IIS console to be able to troubleshoot / compare how things scripted from POSH interacts in the MMC representation. The error I am getting
    might be that I am lacking some IIS components to be in place to be able to automate some parts of the IIS - as suggested by the IIS.CertObj object listed in the example..... I will get back if I can track down which component needs to be added to be
    able to reference the IIS.CertObj object.
    Br4tt3 signing out...
    br4tt3

Maybe you are looking for

  • A Single POP Sound from Left speaker, after system heavy load.

    Hello From Russia)) I bought Brand New Macbook pro 15" Late 2011 Ci7, this is incredible machine. But a month past and i started to notice a very strange behavior: When i using mac for resource "Eating" application or processes my computer starts to

  • MobileMe Galleries Slow and address redirected

    I use MobileMe galleries increasingly with Aperture. They have worked well and are fast and easy. In the last few days, I have noticed a serious slow down with viewing galleries in Safari. Specifically, I've noticed that the page loads almost complet

  • R12.1.3 Vision Instance Product Status are Inactive.

    I have R12.1.3 vision instance. I need to check whether the product are installed are not. so i run the script cd $AD_TOP/sql/ sqlplus apps/apps @adutconf.sql File adutconf.lst will be created in directory $AD_TOP/sql. Check product status by product

  • Tables in Subroutines

    How to declare tables in Subroutines?

  • Lost GlassFish admin password# how to reset admin password

    Hi i lost admin password in glassfish(     GlassFish Server Open Source Edition 3.1.1 (build 12) ) application server key-file stored in glassfish-3.1.1\glassfish\domains\domain1\config\admin-keyfile how i can reset admin password?