Maximum number of Select Images/Vision Assistants

Hardware:         CVS 1454
Two cameras:   AVT Guppy F036C
MAX Settings   
        680x480 Y (Mono 8) 15fps
        Speed: 400MBs
        Packet Size: 680bytes 
        Gamma Off
        Bayer Pattern: BGBG_GRGR
Connection:      Using two firewire cables directly to the CVS
Software:          Vision Builder 2010 and Vision Builder 2009
       I recently started to create a Inspection in VB2010. When I press "Run Inspection Once" button, it would lose connection with the CVS.  I watched the free memory in MAX and it went from 32MBs to 3MBs before it would lose connection. I simplified my Inspection to use fewer states, eliminated most of the variables in an attempt to use less memory. I put the camera settings as low as possible in MAX. Eventually I got it to stop losing connection to the CVS.
       Now that I could go through the states after it went through one iteration I saw that one or both of the Acquire Images would fail. Especially if I went into Inspection Interface and back to Configuration Interface. I figured it was a memory limitation since the CVS 1454 only has 128MBs, 96 of which is occupied by VB2010. I got another CVS, formatted it, and installed VB2009 since it had 44MBs of free memory.
       In VB2009 I put all of the test steps into one long state. The program has:
              two acquire steps in one state
              two states for creating ROIs(one state for each image) for a total of 2 Select Images
              a test state which has two Select Image steps, one vision assistant, along with other test steps
       If I add one more select image or one more vision assistant those steps will simply fail to do anything. The inspection manages to finish running but anything involving that final Select Image/Vision Assistant will not work.
Has anyone else experience a limitation to the number of select images or vision assistant steps they can use? I have a working inspection now but I need to be aware of the limitations as I try to make more robust Inspections.
Is it a problem with the amount of user space in the CVS 1454 or is there just a limited number of pointers in the VB code that limits the number of references that can be made?

My bet is you're just too close to the memory limit on that device. A quick test would be to just acquire images from your camera(s) without any Vision Assistant/processing steps and make sure this works for long periods of time without problems. Use the same cameras, and triggering settings to make it as close The Vision Assistant steps make a copy of the image (as well as Threshold). You can use the Select Image step to see which steps create a copy of the image. If you are really dead set on the CVS, you could try replacing the steps that make a copy of the image with a Run LabVIEW VI that does the same same functionality and minimize the copies you do in the Run LV code. This should save you your image size x the number of processing steps you can replace with Run LabVIEW. You're kind of at the edge of what the HW can do, so I wouldn't normally recommend this, but if you're desperate and don't want to upgrade HW, you could try using Run LV to help do several of the steps in VBAI that are making copies of the image.
Hope this helps,
Brad

Similar Messages

  • Maximum number of still images in a sequence exceeded

    Model Name: iMac
    Processor: Intel Core 2 Duo
    Processors: 2.8 Ghz
    Memory: 4GB
    Bus Speed: 800MHz
    FCP 7.0.3
    So what's the maximum number of still images that are allowed in a single sequence in FCP 7?
    Does it vary from FCP 6, 5, Express etc.?

    http://www.flickr.com/photos/48395063@N07/5328011119/
    http://www.flickr.com/photos/48395063@N07/5328011119/sizes/l/in/photostream/
    You have to zoom in to read the yellow message box that appears when the mouse is loitering over the orange unlimited-time bar above the sequence.
    For your pleasure I have typed it out:
    "Video: Unlimited
    Audio: Media File
    _*The maximum number of real-time still images has been exceeded in this sequence.*_
    A motion of composting effect can not be played in real time.
    Real time playback is not supported for the clip on track 1.
    The nested sequence on track 2 does not match this sequence settings.
    The nested sequence on track 11 does not match this sequence settings."
    Basically we're doing the "Artists Showcase" and artists send in photos and not all of them will be able to match the sequence settings since we take what we can get.
    Besides that the estimated number of still images is 480.

  • Maximum number of selections in an info package

    Hi friends,
    i want to load an ODS with data from MSEG. Due to the great number of records I've to select by
    0ATERIAL. Selection criteria are provided by a routine I'll write for this selection, reading a different
    ODS. Estimated number of records for selection is about 80,000.
    My question:
    Is there any restriction regarding the number of selection criteria of an Infoobject in info packages?
    Will a selection work with 80,000 criteria?
    Any input is highly appreciated.
    Thanks in advance and regards
    Joe

    Hello,
    If I understood correctly...you will compare the values from a DSO and then pass these values in the infopackage selections..
    but how are you planning to do it...will it be interval or single value??
    Also I think you can assign only one value or range in the infopackage at a time for selection through routine...
    More the number of selections more the number of AND in the where clause.
    I am not sure if there is any limitations on where clause but after 100 selection the select queries become complex and overflow the memory...so thats the limitation.
    Thanks
    Ajeet

  • What is the maximum number of input images when using PB in Flash?

    Hi!
    I am experimenting with animation baking using Pixel Bender in Flash. It works fine up to around 12 input images. When I use more than that the output gets distorted or is empty. So I am wondering if there is a fixed limit or if there is a problem with my code.

    I don't think there is a fixed limit. If there was you'd get a runtime error. This may be a player bug.

  • Setting maximum number of image buffers in MAX in IMAQ vision builder

    To aquire large number of images using duncan Technologies Camera (7f/s) on IMAQ PCI 1424 i'm supposed to set the maximum number of buffer images in MAX(Measurement and Automation)in IMAQ vision builder. But i do not see the option for specifying the maximum number of image buffers under the properties of PCI 1424. Please advise.
    Thanks in advance.

    The setting is somewhat difficult to locate.
    In MAX, select "Tools" on the main menu bar. Under that, select "IMAQ". The only option that comes up is "Max number of buffers".
    Bruce
    Bruce Ammons
    Ammons Engineering

  • 2 line carplate number recognition using vision assistant software

    I am doing FYP(Final Year Project). I am using national instruments vision assistant 2010 and want to recognize car plate number.
    I already try out single line car plate number ready. Now my probelm is cannot recognize 2-line car plate number. I also still trying auto detect the car palte number and recognize the car palte number. I don't want to manuals select the car plate number. please find out for me solutions.
    I also attach the file (2-line car plate number photo) also.
    Thanks alots
    Attachments:
    01112011247.jpg ‏1806 KB

    Hello,
    using simple calibration model, you realize that you disregard the lens distortion? It is also advisable that the camera is perpendicular to the inspected object. Here, a telecentric lens helps too.
    The simple calibration performs direct conversion from pixels to real-world units. For example, if you know a real world object that you measure is 10 mm in size and it occupies 10 pixels on the image, then the conversion factor is 10mm/10pix = 1mm/pix.
    So, you want to measure an object with size U (in pixels), you use the equation:
    X = 1mm/pix * U (note that this is for horizontal direction, vertical direction is analogous)
    Best regards,
    K
    https://decibel.ni.com/content/blogs/kl3m3n
    "Kudos: Users may give one another Kudos on the forums for posts that they found particularly helpful or insightful."

  • Images in Vision Assistant are distorted from a FLIR thermo camera

    I'm trying to view my FLIR A315 in Vision Assistant and MAX (not at the same time), but the images keep coming up distorted.  I can tell there is data being sent, because the histogram shows info and if I mess around with the Attributes I can clear the image up some but it never get as clear as FLIR software.  I'm sure I'm missing something simple but this post seemed a good place to start.  Thanks
    Attachments:
    Image in Vision Assistant.png ‏81 KB

    Hi Recordpro,
    It could be your pixel format settings. Open Measurement and Automation Explorer and select you camera. Then click the Acquisition Attributes tab at the bottom and change your pixel format. If that does not work here are some good documents on GigE cameras.
    Acquiring from GigE Vision Cameras with Vision Acquisition Software - Part I
    http://www.ni.com/white-paper/5651/en
    Acquiring from GigE Vision Cameras with Vision Acquisition Software - Part II
    http://www.ni.com/white-paper/5750/en
    Troubleshooting GigE Vision Cameras
    http://www.ni.com/white-paper/5846/en
    Tim O
    Applications Engineer
    National Instruments

  • Rewrite template vision assistance for image match

    hey guys , im using labview to detect an image and record its x-y coordinates.
    does anybody know how i can automatically change , in runtime, the template used to match .
    i get my template from the Vision Assistant Block 
    please please help
    Kevin
    Solved!
    Go to Solution.

    Hey Kevin,
    If you configure the Vision Assistant block and place it on your block diagram, you can then right click on it and select "Open Front Panel."
    This shows you the LabVIEW code that the Express VI is running behind the scenes. From here you can find any parameters you have set, put down as constants. So for example, the file path you chose for the template is on the block diagram as a file path constant. 
    You can right click on this and change it to a control, and then link this control to the connector pane
    Reference: http://zone.ni.com/reference/en-XX/help/371361H-01​/lvconcepts/building_connector_pane/
    After saving this VI, and closing it, you will notice some changes to your main VI. Firstly the vision assistant block will have changed colour to yellow, and secondly, it will have one more input added to the bottom (if you drag it down) which is for the control you set in the subVI.
    The attached example then adds a case structure to select the file path you want to use as a template during runtime. It would be better practice to use an event structure, but hopefully this works for demonstrative purposes.
    Let me know if this helps out Kevin.
    Thanks,
    Justin, Applications Engineer
    Attachments:
    Vision example.PNG ‏40 KB

  • Vision assistant subtract images

    How do you subtract two images?
    I have load two images in vision assistant and I can "flip" between them but I cannot figure out how two subtract them. I guess I need to use the image buffer but it seems to load the same image into the buffer as I am working on. 

    Hi sorinpetrila
    You would get more responses if you create a new post.
    Working with buffers in IMAQ is fairly simple. First you need to figure out if you want a sequence (single run through where you fill up the buffer), or if you want a sequence ring. Where you start to overwrite the start of you buffer after X number of images.
    You would need to use the first option for a single acquisition where you have enought memory to store all the images you want which is normal for if you want to acquire i.e. 100 images and then process them afterwords
    The second option you would use in 2 circuimstances
    1) You have images coming in a burst. 100 pictures wait 1 second 100 pictures wait 1 second.
    2) It takes you longer time to process the image than to acquire it (i.e. 5 times as long). And you would there fore need to store the last 5 images in the buffer so you can handle the longer processing time without acquisition time to go down.
    The best way to learn these techniques is to look at the shipping examples:
    LabVIEW --> Help --> Find Examples
    Browse for task
    Hardware Input and Output --> Vision Acquisition --> NI-IMAQdx
    High LEvel Sequence.vi shows you option 1
    Low Level Grab shows you option 2 as far as I remember (don't have my LV computer here)
    National Instruments have a Machine Vision course which thoroughly walks through these principles and have exercises in both examples.
    Best Regards
    Anders Rohde, CLD, Platinum Applications Engineer

  • Maximum number of "Single values" accepted in "Multiple Selection"

    Hello gurus. I wonder if you could help me with this.
    You know how in transactions like the Data Browser (SE16), you want to look up records in a table, for example MARA.
    If you want to list only individual values, then you can press the yellow arrow to the right of the fields, and this opens the "Multiple Selection" window. In it you can add single values, ranges, etc.
    My question is, what is the maximum number of single values that you can put in here?
    For example, sometimes if I put like 5000 lines, instead of getting a result I get an ABAP runtime error that reads:
    Runtime errors         DBIF_RSQL_INVALID_RSQL
    Exception              CX_SY_OPEN_SQL_DB    
    "Error in the module RSQL accesing the database interface".
    But if I put around 1500 or less, then I don't have that problem. It lists the results just fine.
    How do I know what the maximum number of lines these functions allow?

    Hi
    Yes even I had the same experience and based on my several tests I dont put more than 2000 valeues.
    Please advice if you have any question.
    Thanks

  • Sort key too long - maximum number of columns in select statement

    the sort key too long is caused by either too many group
    functions or too many columns selected. Does anyone know the
    maximum number of columns that can be selected in one statement ?

    The Oracle 9i reference states ...
    The GROUP BY expression and all of the
    nondistinct aggregates functions (for example,
    SUM, AVG) must fit within a single database
    block.
    ... and the Oracle 9i SQL Reference states that ...
    An order_by_clause can contain no more than 255
    expressions.
    You could check your own documentation, but i think it will
    be the same.

  • How do I increase the maximum number of images I can acquire in a sequence using the IMAQ 1424 with 80 MB of onboard memory and a Duncan Tech camera?

    I've increased the maximum number of buffers to higher than I need, but I still cannot acquire more than 139 images with the Duncan Tech digital video camera before I get a memory lock error. Is there any way to increase the number of images I can acquire in a sequence using the IMAQ 1424 with 80MB of onboard memory?

    It sounds like you are already bypassing the onboard memory. If you weren't, you would only be able to acquire about 20 images.
    If I understand correctly, you do not convert the images until after you acquire them. This means each acquired image is 4.13 MB, and 139 images will take 574 MB of memory. I wouldn't be surprised if that was all the free memory available on a 1 GB machine. The operating system, LabVIEW and any other software running probably take up the rest of the memory. You might want to put your computer on a diet and minimize the number of other programs and utilities running. The only other option I see is getting more memory if possible.
    Is there a way that you can reduce the number of images you need to acquire? Pe
    rhaps skipping every other frame? Do you really need more than 139 images?
    Is it possible to acquire the images in monochrome? That would triple the number of images that you could acquire.
    Bruce
    Bruce Ammons
    Ammons Engineering

  • IPhoto v7.1 - Maximum number of images export to Web Gallery

    Maximum number of images that can be exported to Web Gallery??

    I believe that the number is 500 per gallery - total of all galleries would be a function of photo size and iDisk space
    Larry Nebel

  • So I want to use an imaging device with Vision Assistant then incorporate that into my LabView 8.6 code. How can I do this?

    So here's what I have so far written, I have LabView program to interface with my microscope stage, autofocus. I want to try now to interface the camera using Vision Assistant.
    The procedure I want the program to perform is taking this CR-39 detectors and placing them on this stage and the camera to take images of this detector frame by frame. So I want the program to go to the very top corner of the detector on the stage. Then the camera would autofocus (if needed) and take an image. So this would take an image for every micron of the detector on that row. Then move to the next  and so on. Until it has successfully imaged the whole detector.  Is anyone well versed on Vision Assistant and willing to give some advice on this? It would be greatly appreciated.
    The purpose is eliminate the previous method of acquiring images by manually focusing on the tracks created by the particles. I want to this program to run itself without a user being present, so just pressing a button would send the program into autopilot and it would perform the procedure.
    What are CR-39 detectors?
    Allyl Diglycol Carbonate (ADC) is a plastic polymer. When ionizing radiation passes through the CR-39 it breaks the chemical bonds of the polymer and it creates a latent damage trail along the trajectory of the particles. These trails are further ethced using a chemical solution to make the tracts larger which can finally be seeing using an optical microscope.
    Thank you,
    HumanCondition

    Hi Justin,
    Yes I already have a vi that controls the stage.
    So the camera is stationary above the stage. Now what I want to do is get the camera to take the pictures of the detector by moving the stage frame by frame for example starting from the top right corner of the detector (by taking an image) then ending on the top left corner of the detector (by taking an image) then having the stage move down a row and starting the process over again until each frame (or piece) has been imaged.
    My goal is while the stage is moving to every little frame of the detector I would like for it to autofocus if necessary, and take a image to be for each frame of the detector.
    Using the auto focus requires the moving of the stage up and down.
    HumanCondition

  • No Image - 1473R With Vision Assistant

    Hopefully this is a simple fix and I'm missing something very obvious, so here is what's up. I'm originally a text programmer but for this project I'm stuck using LabVIEW which is completely unfamiliar; I've been working on this for days with no progress so I thougt I'd see if anyone had some pointers. The goal of the project is to use the PCIe-1473R FPGA to do live gain control, overlay, and maybe some recognition.
    I started with the "Image Processing with Vision Assistant on FPGA" example and made a few simple changes to just attempt to get a video feed through. The camera we are using is a Pulnix TM 1325 CL, which outputs a 1 tap/10 bit Camera Link signal. Since this example VI is originally configured 1 tap/8 bit I changed the incoming pixel to be read as 1 tap/10 bit and compiled and tested. When I try to start video acquisition I get no errors but no frames are grabbed. The frame's acquisitioned count does not increase and nothing is displayed. If I switch to line scan I get a scanning static image, but this is not a line scan camera and my other NI frame grabber card shows an image from the camera fine.
    I wasn't all that surprised with this result, as the input is 10 bit and the acquisition FIFO and DMA FIFO are both 8 bit orginally. So, I changed them to U16 and also changed IMAQ FPGA FIFO to Pixel Bus and IMAQ FPGA Pixel Bus to FIFO blocks on either side of the Vision Assistant to U16. With this configuration, I again get no image at all; same results. I suspect this is because the incoming image is signed, so the types should be I16 instead. However, there is no setting for I16 on the Pixel Bus conversion methods. Am I not understanding the types happneing here or is there an alternative method for using Vision Assistant with signed images? I'd think it'd be odd not have support for signed input.
    Anyway, I've tried all the different combos of settings I can think of. Does anyone have any input? I feel like it must be either a buffer size problem or a signing problem, but I don't really know. Any and all input is welcome!
    Thanks for helping out a new guy,
    Kidron

    I ended up resolving this issue by switching cameras. The end goal was to use a FLIR SC6100, so I switched to it and was able to get things working shortly. The FLIR does use unsigned ints, so I believe that's what resovled the issue for anyone running into this in the future.

Maybe you are looking for

  • WLC and Radius issue

    We keep get the following error. And everytime we got this, the clients have been force to re-authentication. Any idea? Thanks, RADIUS server 10.108.32.33:1812 activated on WLAN 1 RADIUS server 10.140.4.9:1812 deactivated on WLAN 1

  • Outbound RFC from R/3 ABAP to XI

    Hello, I searched through the XI forum on this, but couldnt get it straight so far. R/3 AP1 -> XI -> Third party system I would like to invoke XI from an R/3 ABAP  like this: call function z_call_xi destination xidest The following is not clear yet:

  • Snownews not opening links properly in Chromium

    I have an issue with Snownews not being able to open links properly. My ~/.snownews/browser file just has "chromium %u" in it. What happens when I open a link is that it opens a new tab in an existing Chromium window and tries to load some seemingly

  • Moving to CM from non-cm

    We are currently tsting moving applications which use Headstart 6i from a non-versioned to a versioned repository. Is there a difference between non-cm and cm headstart application? If so, how do we reconcile the two headstart applications?

  • Lightroom will not open, says it is open in another catalogue

    How do I fix this error notice when I try to open Lightroom, it says it cannot open because it is open in another catalogue, I don't have another catalogue.