Hello,
I want to measure the frequencies present in an incoming analog pulse signal.
I tried it as shown in the vi using ‘Extract single tone information.vi’ which was showing the value as ‘39m’ I dont understand what is this value. Can someone explain the right way of measuring the frequencies present in the signal so that I can feed them to my bandpass filter limits.
Thanks.
Solved!
Go to Solution.
Attachments:
Measure_Frequency.vi ‏102 KB

Hello,
The acquired analog signal is pretty much filtered as shown in the attached image.
Now I am collecting data for 5 seconds (collecting 2500 samples using collector.vi ) and finding the single tone frequency from it and plotting the measured frequency after 5secs in a waveform chart.
But I am confused with these1)The original detected signal has an amplitude of above 1.6V but the measured amplitude only shows 0.6V and 2) how the waveform chart has a plot plotted over the duration of 5seconds  when the frequency is measured for every 5seconds data I mean shouldn’t  the chart has a plotted value of HeartRate plotted  for every 5 seconds.
Can someone explain a bit about these.
Thanks.
Attachments:
Freq.JPG ‏74 KB
Frequencyplot.vi ‏94 KB

Similar Messages

  • Measuring frequency with counter or analog input?

    I have some frequencies which I need to measure. Some signals are digital and some are analog.
    I have a PXI-6040E DAQ which has both counters and analog inputs. 
    I heard that you can measure higher frequencies with the counters than with analog inputs.
    What is the range of frequencies an analog input can determine versus a digital counter? 
    Where is the cutoff that you must absolutely use a digital counter to determine the frequency?
    Is the cutoff different for different DAQ cards? Or is generally the same.

    Have you looked at the specs for the device? The max sample rate and the max counter input will be listed there. The max frequency for an analog input is based on nyquist sampling theory. Are you at all familiar with? It states your sampling frequency has to be at least twice the frequency you are measuring.
    Since each device might have a different max sample rate, your last question is answered.

  • Counter to measure frequency with multiple channels (Analog In/Out) in one vi

    Hi,
    I am using DAQ 6062E. I have multiple channels: an Analog In, Analog Out, Count Edges, and Count Frequencies. Without Count Frequency, the program works fine, I have defined a Sample Clock for each channel and then a common sampling rate. When I add Count frequency channel, I am not able anymore to use Sample Clock, since I get an error that Sample Clock can not be used, and if I change the Sample clock of the Count frequency to Implicit, then I can not connect different channels with a same sampling rate. In the attached file, if the Count Frequency is not connected to any Sample clock and sampling rate, the program works, but now I can not run the program for more than 5-10 Hz sampling rate, otherwise I get the error: 209802 “occurred at DAQmx wait for next sample clock, slow down the sample clock”. Does anybody know how to fix this problem?   
    Thanks a lot,
    Azadeh
    Attachments:
    multiple channel.jpg ‏117 KB

    Hi Otis,
    Thanks for looking at the problem. I ran just two counters in a same vi. I was not able to use the Sample Clock since I needed to define an external sample clock source. The vi is attached. I could run this vi fast (200Hz). So, I am not sure why when two counters are combined with AI/AO the rate is very slow. I have attached three vi(s). Just two counters, AI/AO/1 counter, and AI/AO/2 Counters vis. I am able to run the vis in 200 Hz except the vi with AI/AO/2 counters (maximum sampling rate 20Hz). I appreciate if you can look at it if I am missing something.
    Thanks,
    Azadeh
    Attachments:
    AI_AO_2 Counter.vi ‏153 KB
    2 Counter.vi ‏61 KB
    AI_AO_1 counter.vi ‏138 KB

  • Analog signal duty cycle incorrect

    I am using an NI PCIe 6535 board to send digital timing signals to a custom PCB.
    The signals are digital square wave signals with various duty cycles and phase shifts.
    I also need to send a 12 bit ramp signal to the board.
    I am having issues with the frequency.
    I need the timing signals to run at 833.33333 khz.
    I need the lsb of the ramp to run at 416.666666khz.
    To create the timing signals I am using "Create Analog signal", so that I can set up the square wave with the appropriate phase shift and duty cycle.
    Then I conver from analog to digital.
    I am using a DAQmx generate to output the signal to the PCB. I have noticed that the DAQmx gen frequency directly controls the ramps frequency.
    However for the digital timing signals there is some scaling factor. The frequency of the digital timing signals can be set in the timing signals them selves. The sample rate in the analog signal also effects the frequency.
    To get the frequencies that I need. I had to set the"create analog signal" sample rate at 2.778G S/s, the "create analog signal" frequency to 1.2889GHZ, and the DAQmx generate frequency to 1.66666 MHZ. At those numbers, I get the timing signals to output at 833.333KHZ and the second bit of the ramp at 416.6666HZ (for the ramp I upped it to 13 bit and I don't use bit 0, as it outputs at 833KHZ).
    However at these settings all of my timing signals have the same phase, and the same duty cycle, even though I have them set differently.
    Can someone please help? I think the issue is that I have the sample rate and frequency of the "create analog signal" block set too high, but if I set them lower my signals will not be at the right frequency.
    Attachments:
    timing signal 1.JPG ‏44 KB
    timing signal 2.JPG ‏47 KB
    daqmx gen.JPG ‏55 KB

    Hi David,
    We found that there seems to be a weird divider between the sampling rate of the analog signal module, the analog signal sample rate, and the f daqmx gen.
    After various tests we made a chart of what we observed. Fsignal and sample rate are values set in the "create analog signal" module, Fdaqmxgen is set in the "DAQmx generate" module. We used a "create anaolg signal" module to create the square wave, then convert analog to digital convert the square wave to digital.
    We have "repeated signal" and "N periods" checked.
    Fsignal
    Fdaqmxgen
    Sample rate
    Frequency   measured on the scope
    1GHZ
    10MHZ
    100G s/s
    100KHz
    100MHZ
    10MHZ
    100G s/s
    10KHZ
    1GHZ
    1MHZ
    100G s/s
    10KHZ
    10GHZ
    10MHZ
    100G s/s
    1MHZ
    100GHZ
    10MHZ
    100G s/s
    10MHZ
    100GHZ
    10MHZ
    100G s/s
    5MHZ
    The equation we came up with is Feff = (Fsginal/FDaqmxgen)*1000.
    To meaure the frequencies were using an HP 54600A oscilloscope, and probing standoff pins on our custom pcb.
    We have several versions of the project, attached is the latest one.
    Kyle,
    How do I set the compression to false?
    The picture below looks like labview? We are using signal express.
    I can't change the frequency on the DAQ mx gen because I need the ramp to run at a set frequency.
    There is a divider between the daqmx gen and the f signal. I have to set the Fsginal in the GHZ to get it to out at the right frequency. The equation we came up with is Feff = (Fsginal/FDaqmxgen)*1000.
    Thanks,
    Devin

  • Phase shift, frequency of 2 analog signals, Diadem 9.0 or 9.1

    I have to acquire 2 signals: FORCE (N) and VELOCITY (m/s) for many frequencies parameter in Diadem 9.0 (5 to 150 Hz). This frequency parameter is a analog voltage output signal which is converted in frequency by a frequency vibrator instrument. The measured signals on the vibrator (force and velocity) are considered as SINE Functions. – 1) How do I measure the output frequency of the two signals and how can I save this data ? – 2) How can I estimate the phase shift between FORCE and VELOCITY ? – 3) How can I automate the estimation of the phase shift by the 145 measurement (150-5Hz) ? – 4) Is a continue measurement of Phase Shift depending on the frequency possible ? – Best Regards from Germany and from France.
    Jean-Pierre, Junior Engineer Germany

    Hello KenT. I have test your DIAdem exemple. Your idea with a stop-time was not bad for measuring the phase shift beetween 2 generators by 1Hz. I have used this formula by many phase shift and it works. I had change the 2 generators frequency by 2Hz, and the formula works not anymore and that is normaly because of the reduce of the periode lenght (this problem have I show on Picture 3 of the PDF Data). On the picture 6 and 7 have I try to make another solution. My new solution works only for frequency from 1Hz to 5Hz. What about frequency like 150Hz ? I don't know if you have understood what I realy want to do, but if you have any idea to resolve my problems, please write to me. '[email protected]'
    Jean-Pierre, Junior Engineer Germany
    Attachments:
    DIAdemTexte.pdf ‏435 KB

  • NI9411 wrong frequency measurement of flow sensors / 24 impulse signals

    Hello Ni Forum,
    I already searched for similar problems, but haven't found anything helpful. So I'm posting our problem here. I'm apologizing in advance for bad english, it's not my mother tongue
    We're encountering some strange behaviour of our NI9411 Module. We're using it in a Compact Rio with some other modules (2x Analog In).
    Our goal is to measure the frequency of three flow sensors (impulse high = 24V, 0-22kHz) among with a torque sensor (TTL 5V, 30-60kHz) and a speed sensor (TTL 5V, 0-51,2kHz).
    They are wired as follows:
    DI0a = torque sensor
    DI1a = flow sensor 1
    DI2a = speed sensor channel A
    DI3a = speed sensor channel B
    DI4a = flow sensor 2
    DI5a = flow sensor 3
    Correspondig ports b are left unconnected, as it is said in the data sheet. All ground ports of sensors are connected to COM port of 9411. The module was connected to a 24V power supply.
    Now the torque and speed sensor measurement works fine. But measuring the signals of the flow sensors seems to be difficult.
    If an external frequency generator (impulse high about 9V, f=1,000kHz) is connected to port DI1a instead of the sensor signal, LabView shows exactly 1,000kHz. DI5a showed an avarage of 10 Hz, with a range from 10 to 60 Hz. DI4a equaled constant zero. The flickering up to 60Hz of DI5a was gone after disconnecting the 24V supply of the module. This changed nothing on the phenomenon described below.
    If the signal high impulse voltage is raised, the measured signal frequency goes up to 1300 Hz @ 24V signal high impulse voltage. The signal additionally raises, if an oscilloscope is connected to DI1a, to 2180 Hz (range 2110 to 2240Hz). However, there is no change of frequency if the osci is connected to DI5a. With the 24V supply connected, DI5a showed a frequency up to 600Hz @ 24V signal high impulse voltage on DI1a, also rising when connecting the osci on DI1a. As mentioned, there was no frequency measured on DI5a after disconnecting the 24V power supply.
    The signals of the generator showed some peaks on each edge (rising and falling) with values for example of 11V above high impuls voltage of 9V (20V together). That may causes that wrong frequency measurement.
    The signals of the flow sensors do not have such peaks, the LabView-frequency nevertheless does not match the real frequency, as shown below (all values in Hz):
    LabView
    ideal values
    Flow Sensor 1
    Flow Sensor 2
    Flow Sensor 1
    Flow Sensor 2
    4600
    12200
    740,6
    6760,0
    6400
    13500
    1481,3
    7500,7
    9700
    16400
    2962,6
    8982,0
    12900
    19500
    4443,8
    10463,2
    We're kind of helpless now. How can we get the signals of the flow sensors measured the right way? Are we doing something essentially wrong? Thanks in advance for offered help. I hope, I've given any necessary information. Any missing details will of course be delivered.
    Puls-Measure-VI is attached beneath.
    Regards,
    Johannes Rost
    Attachments:
    vi.png ‏20 KB

    Dear Lynn,
    thank you for your reply. The impedance was an issue that our local technical distributor already suggested to check. According to the datasheet of the flow sensor (see attachement) it can drive a current of 25mA. The signal generator we used is a test generator that can be used instead of the flow sensors to check the any evaluation unit the sensor is connected with. So it should generate signals that are equal to those the sensor would have generated. And even with this the frequencies measured with LabVIEW are not as expected.
    We are in contact with the sensor manufacturer to exclude mistakes in connection on the sensor side. But the behavior with the signal generator makes us think that is has to do something with the characteristics of the NI9411 that we don't know yet.
    Attachments:
    block diagram signal amplifier and signal description.png ‏151 KB
    technical data.png ‏124 KB

  • Determining Analog Signal Frequency with Prebuilt VIs

    Don't know what is wrong with this code.  Am trying to determine the frequency of a signal from an analog signal (paddlewheel flowmeter).  As a starting point, I'm using a simulated square wave with the "Timing and Transition Measurements" VI and am getting following error:
    ~~~~~~~~
    Error -20308 occurred at Timing and Transition Measurements -> frequency_determination_example.vi
    :3"  (waveform index 0 of 1)
    Possible reason(s):
    Analysis:  The waveform did not cross the mid reference level enough times to perform this measurement. Check the signal length, reference levels, and ref level units.
    ~~~~~~~~~
    However, there seems to not be any options in the "Timing and Transition Measurements" VI to set mid reference levels.
    Any insight into why this simple problem is occuring would be appreciated.  Attached is my program's simple code.
    -tsippel
    Attachments:
    frequency_determination_example.vi ‏101 KB

    Hi,
    Dennis was right (without looking at the code). You generate one (1) square wave, if you had generated 1000 sampled you'd get the correct answer.
    Ton
    Free Code Capture Tool! Version 2.1.3 with comments, web-upload, back-save and snippets!
    Nederlandse LabVIEW user groep www.lvug.nl
    My LabVIEW Ideas
    LabVIEW, programming like it should be!

  • Measure Frequency of Digital Signal from DAQ-Board

    I'm using a National Instruments DAQ board and I need to measure the
    frequency of a digital signal from my data acquisition board.
    I know the measure frequency.vi (In diagram - data acquisition -
    counter), but i don´t understand yours implementation mainly in input
    "counter". Because i don't understand the relationship of board channel (for
    signal acquiring ) and the measure frequency.vi.
    Thanks in advance,
    [email protected]

    Hi,
       Attached is a vi which models your signal, and provides a way to measure the average frequency over a window of time. It converts the signal to a sequence of periods. I usually start with this approach because you can save the data in a much more compact form if your sampling rate is high. Obviously over a specified period of time, if there are no zero crossings the frequency is zero, so I was a little incoherent before. The real issue is the latency caused by averaging. Your frequency measurement is most accurate half your window size before the current time, so smaller windows give you more up to date measurements, but also more noisy. If you need the most up to date measurement, then you have to use the time since the last crossing which is the case where the frequency never goes to zero. That's probably not a realistic situation. If you needed less latency, you could use a prediction algorithm.
    Also, there are a number of signal measuring and processing vi's that LV gives you, for instance pulse measurements that could be used to partially implement this or other approaches, but I normally steer clear of them unless they fit exactly due to having to convert back and forth to the waveform data type.
    Have fun!
    Attachments:
    DigRandFreq.png ‏62 KB
    DigitalRandomFreq.vi ‏34 KB

  • Wiring a SCB-68 to measure the frequency of a TTL pulse signal

    Sorry if this is a basic question but could someone please help me and tell me how to wire up a SCB-68 connector block (connected to a AT-MIO-16 DAQ board) so that I can measure the frequency count of a series TTL pulses (signal from photon counting). At the moment I don't understand how the PFI1-9 connections are related to the GPCTR0/GPTR1 counter connections on the block and how they're all realted to the source,gate and out 1-5 connections on the DAQ board.
    Ultimately I want to be able to put this measured frequency into a Labview program with a controllable gate period.
    Thanks in advance
    Nick

    You might want to search the Knowledge Base on the NI's Support Pages for "Cable Mapping for a 68 Pin Connector to a 50 Pin Connector". This should take you to a link that will explain the mapping of a 50way to 68way cable and subsequent lines you are looking for ( reference sub link 68F50M), I guess you have SH6850 cable connected from the AT-MIO16 card to the SCB-68.
    Please check out the information about the pin outs, that should help you work out which pins map to the counters, eg GPCTR0_source would be pin 37 on your SCB-68
    Regards
    Joe (NI)

  • How I can measure frequency of TTL signal without external clock?

    Hello,
    I want to measure frequency of TTL signal using PXI-6254 or PXI-6713, without using external clock.
    Frequency will be up to 100kHz. How I can use internal counter of 20MHz or 80MHz?

    Hi Yuta K,
    You have not stated what software you want to use for this measurement, but in case you're using LabVIEW, please go to the Example Finder (in LabVIEW go to "Help >> Find Examples"). 
    In the Example Finder, you make sure the "Browse" tab is stil selected, and than you go to:
    Hardware Input and Output >> DAQmx >> Counter Measurements >> Digital Frequency
    Here you will find some good examples of measuring a digital frequency with 1 or 2 onboard counters.
    If you need additional information, please let us know!
    Best regards,
    Peter S

  • MyRIO input analog signal measurement

    Hi everyone,
    I want to know that how to measurement the input analog signal from a signal generator to the input pin of myRIO. Is it like using myDAQ to measurement? or need to use other Labview function panel? For example, how to trigger the input signal on Labview?
    If someone know this, please give me an answer.
    Cheers,
    Johnson

    Hi Johnson,
    The minimum software required to program the NI myRIO processor with LabVIEW is the following:
    LabVIEW
    LabVIEW Real-Time Module
    LabVIEW myRIO Toolkit
    All of this software is included in an Academic Site License. Additionally, the full myRIO Software Bundle can be downloaded from ni.com and activated with a valid serial number.
    You can write programs quickly using I/O-specific Express VIs directly from the LabVIEW palette, which includes an "Analog In" function which you can use for your signal generator input:

  • How can analog signals are measured every several counters from Quadrature Encoder using USB-6221

    how can I sample analog signals every counters from quadrature encoder using usb-6621?

    There is a well documented example of what you are trying to do at :
    http://zone.ni.com/devzone/explprog.nsf/webmain/DD85F07A7CA99F8F862568690062DE54?opendocument
    Don't be afraid because of the BNC-2120. It is just used in this example to simulate the pulses from a device. So it is not needed in your case. Obviously, you will need to change the number of increments/rev according to your encoder to get correct RPM values.

  • Problem when combinning PWM signal and Analog signal TOGETHER!

    Hello everybody,
    first of all i have DAQmx 6212, and i need to run a small water pump (9V-16V) which needs to be driven by a PWM signal; also i have a motor (5V-13V) for a water valve that needs to be driven by a analog signal and it has a built in a force feedback potentiometer, i connected on the extremeties of this potentiometer +5V from the DAQmx and used the output voltage from the third extremety as a diagnose value for knowing the position of the motor.
    my VI shows:
    1. is a normal Counter output to create my PWMout signal.
    2. is an analog input i use it as a PWMin to the LabVIEW to diagnose what is happenning in my water pump through the duty cycle and the frequency.
    3. is an analog input from the third extremety of the potentiometer.
    4. is an analog output which i have used as a power supply for the motor valve and i have used an AC/DC amplifier to aplify the signal from the DAQmx and drive the motor, between (3. and 4.) i have made a feedback with some calculations i had a P-controller to know the actual position of the motor valve.
    My Problem:
    when putting 1. and 2. in the same VI alone, i am getting a clean PWM in/out with no problems mentioned;
    also when putting 3. and 4. in the same VI alone i can control the motor valve without any problems;
    but when i put all these 4 together as found in the attached VI, i have a problem that the motor valve is running continously without stopping even if i change the valve position between 0 and 100 %, i should mention that i am seeing a normal PWM out/in signal on my oscilloscope, one other thing that if i delete one of (1. or 2.)  and run the VI the motor valve is working fine without any problems.
    so this my problem, if you can think of any solution please let me know.
    thanks in advance for your help.
    Regards,
    Alosh
    Solved!
    Go to Solution.
    Attachments:
    pwm.out.in.analog.out.in.vi ‏45 KB

    Dear nathand thanks for your reply,
    i have ran the vi again and i am have error no 50103 from the (AI, number 3. )  but it is not displaying the error message, the VI keeps running without any error notification.
    adding to that,  i have tested the VI again today by placing (1. and 2.for the PWM inout) together in one VI and (3. and 4.for the motor valve) in another VI and ran them one after the other, i had another problem. if i turn the motor valve vi, the motor will run smoothly but in the pwm vi i will have a problem in which the AI did not read any value. also doing this vice versa by running the pwm vi first it will work perfect but the motor vi will have problem in reading the measured voltage in AI during this the motor will keep on running without stopping.
    so i think now the problem is in AI (2. and 3.) readings they are interfering on each other but i am not discovering where is my problem...
    Q: does the AI's seems well build or i can do it in an another way so to get over the interfering?
    Regards,
    Alosh

  • How to Measure frequency of less than 300 Hz

    Is it possible to measure frequency without a counter module? All I have is a cDAQ with 9205, 9221 and 9263 modules.

    Hello,
    I am assuming that you want to measure analog frequency, since you have analog input and output hardware.  There is a useful LabView Help file titled Measuring Analog Frequency.  You will be able to measure analog frequency using just software and no counters.  However, this involves using Fast Fourier Transform (FFT) functions that are only available in LabView Full and Professional versions.  Please also take a look at the examples in the Example Finder.  Some helpful ones are titled … Signal Generation and Processing.vi, Spectrum Measurements.vi, and Simple Spectrum Analyzer (sim).vi.  These example’s block diagrams are a little busy, however you can see how they are using simulated signals with the FFT Power Spectrum.vi.  Note that the example titled Spectrum Measurements.vi uses express functions.  These functions are going to involve less programming, but offer lower program efficiency.
    Samantha
    National Instruments
    Applications Engineer

  • Is there a VI availible that will allow one to interact with an analog signal

    Hello all,
     I am new to the sight and look forward to participating. I have a project that I’m working on and I would like to ask for your thoughts and direction if you’re willing. I have a few weeks left before completing an electronics program degree and Labview is one of the classes. The project I have chosen is to illustrate the differences between a micro controlled system and Labview controlled environment. I will be  acquiring a signal through a ultra sonic distance sensor. The analog signal will be produced after which  acquired  through a SCB – 68 connector block and converted using the pci-mio-16E. The sensor operates at 40 kHz emitting a 5v pulse (burst) then falling to gnd for a short period followed by a 5v rise and staying high for a period of time waiting for the return of the frequency. This time period represents 3 inches to 27 ft in distance.  I would like to interact with this signal through the distance period (portion) and output a string displaying a numeric value of the distance on the front panel obtained from an array built from different periods of the signal.  I am not clear on what Labview function offers this type of control.  I am hopeful in utilizing a vi or some type of trigger that allows me to build an array produced by some math functions.  Any help would be appreciated.
    Thank you, dhitch

    First thank you for your response, I will have an opportunity to make a capture tomorrow in class.  I believe I have run across the waveform measurement VI in my searches and am sure it’s a very good choice. The trigger VI you suggest, going by the name, should be my ticket. Would you imagine a delay or decreasing time after the capture, allowing the trigger VI time to respond to an output configuration be required?
    If I remember correctly the sampling rate capabilities are 500K samples/ second with 12 bits of resolution and as I say that it seems some of the capabilities rely on the processing speed of the computer. I guess I will kick the tires tomorrow hey.  There are 2 class periods remaining to finish our projects @ 2 hrs / class and my anxiety is a bit high. Wish me luck and thank you so much.
    dhitch

Maybe you are looking for

  • AE appends my filename when setting up a render queue output filename via scripting

    I wrote a script that imports quicktimes and creates comps from them and adds them to the render queue. I'm running into an issue where files with certain names get appended when adding them to the queue. I believe it has something to do with the "."

  • I had updated itunes and now have no songs when I open itunes, do I have to do something else?

    I had updated itunes and now have no songs when I open itunes, do I have to do something else?

  • How can i query oracle database data to xml file with c++?

    I want query data to xml file directly in my c++ application . I know the oracle XSU provide interferce for query data to xml file directly. But XSU for oracle8i does not support c++. I do not know if XSU for oracle9i support c++. can you tell me? If

  • Single edition App

    Hi, I've a Professional Edition account. I want to create a Single Edition App for iPhone but with my app builder a can select only "Più Folio". See attachment ("iPad_and_iPhone") If I select only iPad I can create an App Single Edition. See attachme

  • Z520a and iSync

    Hi, Ive got a SonyEricsson z520a and need to sync to my mac, a G4 with OsX 10.3.9, with iSync 1.5. I've looked in the supported devices page of iSync 1.5 and 2.2, my phone isn't supported in iSync 1.5. Does anyone know of a way to get this to work, w