Missing Data in 0FI_GL_4 delta loads.

Hello All,
We  successfully loaded the 0FI_GL_4 related ODS upto 02/06. We turned on delta loads for the same from 03/06. The data validation team has discoved that there is missing data in 03 and 04. I plan on resetting the delta queue in R3 and reinitialize a full load until april. Here are my questions
1) Are there any specific steps i would need to follow?
2) Are their any other better alternatives then reinitializing with the full load.
Thanks in advance.
Kiran

Initialization Concept :
I will explain this with an example.
You have 5 company codes (CCs) (1000, 2000, 3000, 4000, 5000) in your R/3 source system.
But your client wants reporting in BW only for 3 Company codes (CCs) (1000, 2000, 3000).
In that case, there is no point in bringing the data for other 2 CCs.
So during Initialization, you give the inputs as,
CC = 1000, 2000, 3000 and do a Initialization (With or Without Data transfer)
So henceforth, when Delta is pulled, any changes corresponding to CCs 1000, 2000, 3000 only will be captured.
Eventhough there are changes in 4000 & 5000, they will not be captured in the Delta.
Hope I answered your Question.
Regards,
Balaji V

Similar Messages

  • Records are Missing when we run Delta Load( FIGL-ACCOUNT ITEMS)

    Hi,
      Some records are missing when we run Delta load.
    We have one generic data source on FAGLFLEXA table.
    We select  Field nm TIMESTAMP
    TIME STAMP IS LOCAL.
    upper limit is Blank
    Lower limit is 1000.
    we run this process chain every day.
    we select delta settings is New status for changed records.
    Please give me any idea why records are missing when we run deltas.
    Thanks
    Naik

    Hi Anju,
    Please ensure that you are following the below steps while Initilizing the application 13:
    1. All the users in source system, must be locked.
    2. Ensure that SMQ1 and RSA7 are having no data for application 13. Delete the application 13 datasource entries from RSA7.
    3. Delete and refill the setup tables for application 13.
    4. Run a INIT with data transfer load for the required datasources of application 13.
    5. The Deltas can follow from the next day.
    This will ensure that your deltas are fetching correct data. Note that, delta will pick up the same conditions on which the INIT load was run.
    Please let me know if you need any more information.
    Regards,
    Pankaj

  • Data Recovery from delta loads

    Hi Everybody,
    We pull GL Item data from R/3 to BW on a nightly basis using the 0FI_GL_4 extractor using delta updates with a process chain.
    The process normally starts around 01:00 CST. At around 01:37, there was a problem with the database for R/3 and our extraction job was cancelled. No data was transferred to BW. No PSA entries were created in BW.
    Later on, we executed the same process chain again. This time, the process chain completed successfully. However, the system said there were no new delta records. Since it is in the middle of the week and
    there are only a few days until month end financial close, we should have many GL records.
    We need to find out if we lost any GL data, and if so, how is the best way to recover.
    Thanks in advance
    Varun

    Hello Srini,
    Goto Delta Queue, RSA7 -> Display Data enteries -> there you select Delta Repetition option for update mode and then execute. Now you should be able to see some records for the extractor. Then pull it into BW.
    GSM.

  • Missing PO's from delta loads.

    Hi All,
    I am facing a peculiar problem as following:
    Datasource : 2lis_02_scl
    r/3 field        :elikz(final delivery indicator)
    Update mode is 'delta' to one ODS.
    Loads are correctly running as expected but recently noticed that BW field 'final delivery' is not getting updated for many PO's.In R/3 PO's having recent values for the field 'elikz' ,which ideally should have come as part of deltas in BW but unfortunately this is not happening.
    Since I am not sure about the exact number of PO's missing in BW ( not sync with R/3) , so I cannot pull these pariticulars PO's with 'full repair request'.
    If anyone encountered this kind of issue or have some clue about the reason, please revert.
    Awaiting your responses.
    Thanks,
    Shiv

    Hi,
    Did you solve this issue? I have a simialr issue even a full repair request of certain POs did not solve the issue. The field ELIKZ is filled wrong in BI.
    Regards
    Selin

  • Why can't see enhanced data by delta loading

    Hi Pros,
          I have done enhancement in 0CA_TS_IS_1, which constantly retrieve information and append them into data package, then I tested it in RSA3, successfully. also I load data from this 0CA_TS_IS_1 by full loading, it successes. but when I load data using existing delta load infopackage, there is no expected data loaded. ( ie. there is no enhanced data appended).

    Put a debug breakpoint in your code, and then run RSA3 again in Update Mode delta (D).
    Check if the debugger goes into your breakpoint - it should.
    If it doesn't , it may be your user exit is not activated correctly, or there is some clause in your code (check for IF-ELSEIFs) that bypasses the customer exit only during delta loads.
    I hope you did the user exit correctly, because these things normally do not happen at all when implemented correctly. There are a 101 different things that could've gone wrong when these things happen. My advice is to check and re-check your user exit code in the program ZXRSAU01 to make sure everything is setup correctly.

  • Is there settng source system level for master data delta loading perfo

    Hi Viwers,
    Good Morning,
    I am loading data from the source to target level for Master data it is taking too much time,I would like to know the how to increase the master data delta loading performance.
    I would like to know the source system level is there any setting requited & target system level also.
    Please give your inputs..........
    Thanks & Regards,
    Venkat Vanarasi.

    Venkat -
            Are u deleting the indexes of data target before delta loading ? If not,delete the indexes of data target before delta loading  and recreate them after delta loading is done.This procedure increase load performance.You can perform whole procedure in process chain.
    Anesh B

  • Delta Load failure from ODS to Cube

    Experts,
    After CRM upgrade, I had to reinitilized the delta process. In this, I reloaded ODS with first init delta without data and then delta load with new data created in CRM. This worked good so far. After this when I tried to load cube with init. delta without data, no issues. But delta load from ODS to Cube doesn't work. Does anybody have any suggestions, please?
    Thanks,
    Nimesh
    Following error observed in Status for delta load from ODS to Cube.
    Error when transferring data; communication error when analyzing
    Diagnosis
    Data Packets or Info Packets are missing in BW, but there were - as far as can be seen - no processing errors in the source system. It is
    therefore probable that an error arose in the data transfer.
    With the analysis an attempt was made to read the ALE outbox of the source system, which lead to error .
    It is possible that no connection exists to the source system.
    Procedure
    Check the TRFC overview in the source system.
    Check the connection of the source system for errors and check the
    authorizations and profiles of the remote user in both the BW and
    source systems.
    Check th ALE outbox of the source system for IDocs that have not been

    Hi,
    As far as i understood, you have successful deltas' loading to the ODS and you want to update entire ODS data to the Cube followed by daily delta's.
    If this is the case,
    Make sure that you have active update rules exist between ODS and Cube.
    First goto your ODS and right click and select option 'Update ODS data in data target'.
    Select Init update > IT will take you to the init info package where you select init <b>with data transfer</b> (Init with data transfer will bring all the records from ODS to Cube)
    Once init is completed ,you can schedule to load delta's regularly form ODS to Cube by following the same steps.
    Hope this helps
    Praveen
    Message was edited by:
            Praveen Vujjini

  • Issue with delta load from R/3 to BW

    Hi frnds,
    There is a standarded D.S  2LIS_05_ITEM in R/3. Evereday We extraceted data from R/3 to BW based on this standard Data Source with delta load.There are two fields ZX and ZY in BW ,some times the data haven't extracted for this 2 fields in BW with the delta update.But some times this 2 fields properly extracted in to BW with the same delta update.
    Why is it happen like this ? Please give some inputs on this.
    Regards,
    Satya.

    Hello,
    if its a standard field then its getting populated in correct way.
    if its custom field then you need to analyze the records for which its getting populated and for one which its not.
    Quite possible that some cutomization in CMOD results in this behaviour.
    Also,check underlying tables to see the correct values.
    Regards
    Ajeet

  • How to go about multiple inclination with different data selection in Delta

    We have to copy large amount of data ( more than 42lak of recodes) selectivly from on ODS to other ODS. in delata load ( BW 3.5 enverioment)
    I thought of loading data in slices through delta loading with selection condition.
    step 1> Do The initialization with selection condition as for calyear =2001 ( Init without data transfer )
    step 2> Take the delta load .. it will take all delta record with same selection
    step 3> Now I want to do Initialization with selection condition as for calyear =2002
    step 4> take the delta now it will take delta for year 2001 and 2002 both Right ?
    Here what problem I am facing.. while doing 2nd time initialization it prompt me to delete the last  initialization request form scheduler menu.
    if i delete the last request .. will it take the delta  for previous initialization selection  and new initialization selection. ?
    Please advice how to go about multiple inclination with different data selection in delta loading.
    Looking forward your reply.

    Hi,
    step 1> Do The initialization with selection condition as for calyear =2001 ( Init without data transfer )
    step 2> Take the delta load .. it will take all delta record with same selection
    step 3> Now I want to do Initialization with selection condition as for calyear =2002
    step 4> take the delta now it will take delta for year 2001 and 2002 both Right ?
    You are correct with this scenario normally. The message you mentioned normally comes up when you open a infopackage and don't change the selection first or in case you have overlapping selections with an already done init.
    regards
    Siggi

  • 0BPARTNER  delta load problem

    Hi All,
    For 0BPARTNETR master data  , its a delta load and infopackage is showing red but request inside the Data Target is green with 0 added records. But some times it picks the delta figures and sometimes it will show 0 added records . Please assist me regarding this .
    Regards,
    Aditya

    When there are no changes in the master records in R/3 then 0 records will come in delta..
    if only records are created or modified then only it will pull delta..records.
    Now when request is red you can make its status red manually i.e status not okay and then run repeat delta and check if load is happening...
    in infopackage settings..we sometimes put the status preference green or yellow if its stuck for long time...you can check this out ...go to infopackage menu bar and left top corner you can see those options..
    Regards
    RK

  • Delta loading?

    what is delta loading?
    why it is need to do a init load before delta?
    the  procedure and mechanism for the delta loading?
    thanks
    Please search for available information before posting.
    Edited by: kishan P on Jan 24, 2012 11:02 AM

    Hi,
    Full Load :- When all the records are transferred to data target from data source.
    Pseudo Delta :- Its a Full data load with some selections like calenadar month , fiscal period or any other IO filter in the DTP or IP.
    Init Data Load :- Its required before starting any delta load. It puts the data mart status to the data source after data load . It can be with or without data transfer.
    Delta load :- Data load of the changed data after the Initialization of the data source. It loads all the data arrived in the data source after initialization or which do not have data mart status set.
    You can get more information about Delta and Init from following links :-
    http://help.sap.com/saphelp_nw70ehp2/helpdata/en/44/97437799ee70dbe10000000a1553f6/content.htm
    http://help.sap.com/saphelp_nw70/helpdata/en/d0/4cc138944cfa06e10000000a11405a/content.htm
    Navesh

  • Skipped delta loads

    Hi,
    I skipped loading the data for the delta loads for about a week ago, that is, I have not scheduled the load daily, I suppose that if I load now, will that be enough to get all the delta changes between last week and now? Is it necessary to schedule the delta load daily?
    Thanks
    "<i>I can't give you a sure-fire formula for success, but I can give you a formula for failure: try to please everybody all the time.</i>"   ~ Herbert Bayard Swope (1882 - 1958)

    If you have not loaded delta since one week next della load will pick up all the data since last delta load. Whether to schedule daily or weekly depends on how frequent data changes on the source and how much lag in data in source & BW is acceptable to business users . Transaction data delta load is mostly daily and master data can be weekly / monthly .
    Regards.
    Sanjay

  • Issues with Delta Loads.

    Hi All,
    I hope you don’t mind to provide a suggestion about the delta load of Purchase Orders.
    There was a request from Procurement team and they complaint that the data is not looking right.
    For example: for a given purchase order the exemption flag is displayed as ADE.
    Before change:
    Purchase Doc Number
    Puchase Exemption flag
    90002106
    ADE
    They want this to be displayed as:
    After Change :
    Purchase Doc Number
    Puchase Exemption flag
    90002106
    So ABAPER has included the logic in ECC Functional Module to populate the Extract Structure for Data Source to display above result. But the overnight run didn’t pick up the changes to above record in BW. The loads are delta loads.
    So my Question is:
    ·         This load for the Infocube Purchase Orders is delta load.  Does change to Function Module will pick up the changes to old records as well? I mean if we are doing delta load does the old records gets changed and updated in CUBE or should I delete the data from all the PSA and Infocube and run the load into CUBE to pick up the changes. Am bit worried about deleting the data from Infocube as it may have history data (because of delta load).  Total records in cube are 800000 records.
    ·         Another question does the process chain trigger the function module to load the data into Extract Structure of data source in ECC (am bit confused about this process in ECC)?
    Please suggest me how can I capture those changed records?
    Any help would be much appreciated. Please let me know if you need more info.
    Thanks in advance
    Sandeep

    Hi Sandeep,
    I am little confused from your post. You are using  2lis_02_SCL or the  generic FM datasource?.
    Also it looks like new  custom field added in your client. I never saw any purchase exemption flag even though i am working in purchasing flow for  last 2  years.
    W.r.t purchasing , deletion flag will be there  which  will come from EKPO and have  the values S or L (  Deleted or Blocked).
    You can block or delete a PO aslong as GR was not happened. Other wise you can do it. So use the EKPO-LOEKZ for  your use.
    Regards,
    Rajesh

  • Missing some master data for delta load( its very urgent please)

    Hi,
    I am working master data for delta load,the problem is when ever changes(SO) in r/3 RECORDS for address text,City Dstrct Nm.its not getting loaded into BW.every day some delta records are coming into BW.
    the data coming thru bw satging and bw.Please help what would be reson and where can i find the detail info,where is it missing.Please see below for example.
    Address Number/     Addr Ln 1 Txt/     City Dstrct Nm
    9025750333/                      #/               #     
    help me its very urgent

    Hi Sumanth,
    check the delta queue and the V3 job is it running correctly ,
    Have a look at OSS note :728687
    and also see the following thread
    Deltas are not available in Delta que
    Delta Queues are not cleared in R/3
    No data in RSA7 for 2lis_03_bf : HELP
    check the data may b it is in modifide status not active.
    regards,
    supriya

  • Delta Loads are not working: 0FI_GL_10 With enhancement : HR Data in source

    Hello Friends. Thanks for your answer on theory which I know, Please help me with this situation. I read all the sdn response to my message and have below for your suggestion
    QUES1: Why the 0RECORDMODE is not coming in Standard DSO and hence it is not there in Transformation in between Infosource and DSO. What do I need to include 0RECORDMODE in standard DSO. What is the correct OSS to Implement on SP 10 to solve this.
    Ques2. As suggested by you If I run the Delta loads after waiting for 1 hour of Init load. say init load was done at 11 am . i will do the delta at 12:10 am to psa via Infopack and then wait for an hour to run the DTP from PSA to DSO. Delta Records come in but it also bring in the records in DSO that are not changed from about 7 hours in ECC. and make our total Balance incorrect.
    Ques3: We have this Cocatenation of Keys in DSO since we exceeded the total number of 13 key in DSO.
    Cocatenation#1 GL ACCT and CHRT OF ACCTS
    Cocatenation#1 SEGMENT AND CONT AREA
    Cocatenation#1 Version, Value Typem, Valuation view, Currency Type.
    <b>
    Since business want to include HR Data in Keys Like Employee Number, Emp Code, EMPSPIMCODE. Payroll ID and I can not remove these fields from Key in DSO as per the business.</b>
    Also the above fields GL ACCT , CHRT OF ACCTS, SEGMENT, CONT AREA
    exist in Data FIELDS OF DSO. so what are the steps to modify the design to fix this asap.
    Please email me at [email protected] if you have any docs to resolve the above
    Thanks
    Soniya
    null

    Did the full load bring all records from sourcesystem to PSA?
    Was this an issue with the first delta you have tested ?
    Concatentaion of multiple keys into one should not be an issue here as that must have been happening in DSO and delta brings incorrect records to PSA itself.
    Are you validating delta records against FAGLFLEXT inputing the timestamp value  or RSA3 ..how ?
    <b>Check if this note helps</b>
    Note 1002272 - NewGL-DataSource 0FI_GL_10, 3FI_GL_*: Missing record.
    Is delta bringing incorrect records to PSA or DTP brings incorrect records to DSO from PSA ?
    May be you should revisit the logic behind for the enhancement of 0FI_GL_10.
    I am facing a similar issue as well but here delta doesnot even bring a single record ( ODS has 20 keys )...will update if resolves and you do the same.
    Message was edited by:
            Jr Roberto

Maybe you are looking for

  • Downloaded new OS and having trouble with wifi, bluetooth Facebook and Skype performanc​e

    Dowloaded 10.2.1.537 When I first loaded this it had a lot of trouble finding my Wifi again and would disengage.  Problem went away after a few hours but it recurred this am.  Also affected Facebook. Skype is loading more slowly and jumps to a black

  • How to make a backup of just files for Windows 7 bootable?

    I know this is a longshot, but I was wondering if it's possible at all to make backups of a Windows 7 Boot Cam partition, of just the files, bootable in any way so that I can restore it back as a Boot Camp partition? I used Carbon Copy Cloner to back

  • How to make an acquired array of data work with point-by-point functions

    Hello everyone, I am working on a LabVIEW project using the Measurement Computing PCI-DAS6402/16 board. I am attempting to use point-by-point analysis with data acquired from the board, but I am having some difficulty. I am currently only able to acq

  • XML Data w/ plsql

    Greetings, Case: Trying to create a report on eBS and XDO combines to plsql as xml data source. Problem: When I execute the procedure, Only one single record is generated, whereas the underlying sql statement retreives more rows. Question: Could you

  • Rendering transparent background for website video

    I have a comp for a website that I'm doing. I have a transparent background and some fading in WHITE text with a light ray animated behind it. I have followed instructions on how to render with the transparency intact (Quicktime, PNG, RGB+Alpha, Mill