Missing functionality if storing TDSM from LabVIEW

In DIAdem File Browser window is selected a file from DIAdem 11.0 Examples directory. File FFT_Expl_1 has icon with „tree pictogram“ and „tree pictogram“ can be expanded to see content of file (Time, Oscillation), bellow of File Browser is displayed many file properties. Anyway these properties are not displayed in DataPortal area?!? See picture 1.
Pict. 1
If I click on the file content in tree hiearchy channel Oscillation I can see properties for this channel and small graph with the signal preview. See picture 2.
Pict. 2
To make my own data I have used examples from LabVIEW 8.6. One of these is on the picture 3 TDMS - Express write data (time and frequency domain).vi.
Pict. 3
Every time I create TDMS data from LabVIEW 8.6 (it doesn’t matter which example I use) I see in DIAdem File Browser instead of tree icon the question mark icon?!? The question mark icon cannot be expanded by clicking on it?!? Also the amount of Shown properties is significantly lower in comparison with DIADem example files. Also no signal preview is displayed?!? How to proceed with LabVIEW and TDMS function to have possibilities of DIAdem example files?
Screenshots are in attached DOC file. 
Please help
Bilik
Solved!
Go to Solution.
Attachments:
TDMS problems 2.doc ‏289 KB

Hello bilik,
Thank you for the great description of your problem, the Word document with the screen shots really helps with the troubleshooting.
It looks to me as if you haven't indexed the directory where your TDMS files are stored. The "?" icon indicates that the file is not indexed. If a file is not indexed, only a subset of the properties are shown in the dialogs.
The easiest way to solve this issue is to index the directory that contains you data files (your directory icons are grey, they should be yellow). This can be done by going to the directory (or subdirectory) in the DIAdem NAVIGATOR window, and right clocking on the directory name. From the context menu, select the function "Add Search Area ..." - your directory will then be transferred to the Search Areas part of the NAVIGATOR and all the TDMS files will be indexed. At the point the files will show all the properties and the "?" will disappear.
Let me know if that helped,
     Otmar
Otmar D. Foehner
Business Development Manager
DIAdem and Test Data Management
National Instruments
Austin, TX - USA
"For an optimist the glass is half full, for a pessimist it's half empty, and for an engineer is twice bigger than necessary."

Similar Messages

  • Missing function when running a .exe labview program

    Hi
    everyone,
    I have used
    a subvi taken from the RoboIO library  ( http://www.roboard.com/labview/Labview_RoBoIOv15b.zip) to make up a program in order to run a
    .exe version of it on another computer that doesn’t have Labview (just Run Time Engine
    SP1 is installed).
    The .exe
    works fine on the Labview computer (after adding to the Build/Data directory the
    RoboIO.dll, RoboIOv15b, winIo and WInIO.dll files.). I have no conflict message
    when opening the Project explorer manager dependancies.
    When I
    launch the .exe on the second computer I get a message saying it can't find the
    function I was talking about at the beginning of my post. (running another .exe without
    this function works fine on this second computer)
    It’s the
    first time I am using a .exe on a "non-labview computer", so I must be doing something
    wrong : not creating correctly the .exe program
    Would anybody
    have an idea what could be  the problem?
    Thansk a lot,
    User

    Hi
    To deploy an application in a computer that doesn't have LabVIEW you could create an instaler than an exe.
    You can find how to create an instaler in the LabVIEW help.
    Regards,
    Nicolas M.
    National Instruments France
    #adMrkt{text-align: center;font-size:11px; font-weight: bold;} #adMrkt a {text-decoration: none;} #adMrkt a:hover{font-size: 9px;} #adMrkt a span{display: none;} #adMrkt a:hover span{display: block;}
    Journées Techniques LabVIEW 2012 : du 27 septembre au 22 novembre
    2 sessions en parallèle : Débuter a...

  • Calling SQL Stored procedure from PLSQL function

    Hi,
    I have created a simple function to return a value that is pulled back from SQL server.
    FUNCTION
    FUNCTION CALC_PASS_FAIL
    i_lidded_sn IN TMP_CHIP_ATTR.LIDDED_SN%TYPE
    RETURN NUMBER
    IS
    tmp_result NUMBER;
    BEGIN
    [email protected](i_lidded_sn,'OadmBarActive',tmp_result);
    RETURN tmp_result;
    END CALC_PASS_FAIL;
    OUTPUT
    --When executed as a procedure, i get the required output:
    DECLARE
    x INT;
    BEGIN
    x:=EQDAS_MISC.CALC_PASS_FAIL('OADM004548');
    dbms_output.put_line(x);
    END;
    0 <------ expected output
    PL/SQL procedure successfully completed.
    When executed as a simple function call, i don't get any output:
    SELECT CALC_PASS_FAIL ('OADM004505') FROM dual;
    Any input will be greately appretiated.
    Thanks,
    Shashi
    PS: I am using the DB Link setup usign DG4MSQL

    just wondering it works as procedure as the function misses double quotes:
    dbo.GetChipPareto
    should be
    "dbo"."GetChipPareto"
    Message was edited by:
    kgronau
    Tested a small example using a function like:
    create or replace function test(
    v_ut1 in varchar2)
    RETURN varchar2
    IS
    v_ut2 varchar2(255);
    BEGIN
    "dbo".OTG_TEST3@dg4msql( v_ut1, v_ut2);
    RETURN v_ut2;
    END test;
    The function calls a SQL Server procedure OTG_TEST3 just returning the passed string and it guarantees data integrity.
    Result using a stored procedure:
    SQL> DECLARE
    2 ret integer;
    3 v_ut1 varchar2(255);
    4 v_ut2 varchar2(255);
    5 BEGIN
    6 v_ut1 :='Hello World';
    7 v_ut2 :='';
    8 "dbo".OTG_TEST3@dg4msql( v_ut1, v_ut2);
    9 dbms_output.put_line('Input value: ' ||v_ut1||' - Output value: '
    ||v_ut2);
    10 END;
    11
    12 /
    Input value: Hello World - Output value: Hello World
    And calling now the function:
    select test('Hello') from dual;
    returns Hello

  • Java Stored Procedure via Function Give 0RA 600 from SQL Workshop and App

    Hi,
    Anyone experienced stored procedures or functions failing when called from APEX app or SQL Workshop ( ora 600 ) yet they work fine when called from SQLPlus?
    Sqlplus connected as my apex workspace schema owner:
    select net_services.test_db_connection_via_ldap(
    'APEXPRD1', 'test1', 'test1', null ) as result from dual;
    RESULT
    The database connection attempt was SUCCESSFUL
    From Apex Sql Worshop:
    select net_services.test_db_connection_via_ldap(
    'APEXPRD1', 'test1', 'test1', null ) as result from dual;
    ORA-00600: internal error code, arguments: [16371], [0x434B08150], [0], [], [], [], [], [], [], [], [], []
    NOTE: Same result when run in response to button push on page in application.
    Apex Version: 3.2.1.00.10
    Oracle Version: 11.1.0.7.0
    NOTE: I am using the embedded plsql gateway; was going to try NOT using it to see if it was shared server related (seemed to be from trc files)
    Any ideas?
    Since the code works from sqlplus, I know that it's good: Here some snippets
    -- ========================================================================================
    public class NetServices extends Object {
    public static String doTestDbConnectionViaLdap
    String piDbConnUrl,
    String piUserName,
    String piUserPassword
         String vResult = null;
    try
         Connection conn = null;
         OracleDataSource ods = new OracleDataSource();
         ods.setUser( piUserName );
         ods.setPassword( piUserPassword );
         ods.setURL( piDbConnUrl );
         conn = ods.getConnection();
         conn.close();
         vResult = "The database connection attempt was SUCCESSFUL";
    } catch ( SQLException e )
         int vErrCode = e.getErrorCode();
         String vErrMsg = e.toString();
              if ( vErrCode == 1017 ) {
              vResult = "The database connection attempt FAILED! Incorrect Username or Password";
         } else if ( vErrCode == 17433 ) { // Null Username or Password
              vResult = "The database connection attempt FAILED! You must provide both a Username and a Password";
         } else if ( vErrCode == 17002 ) {
              vResult = "The database connection attempt FAILED! Net Service Name was Not Found";
         } else if ( vErrCode == 17067 ) { // NULL Net Service Name
              vResult = "The database connection attempt FAILED! You must provide a Net Service Name";
         } else {
              vResult = "The database connection attempt FAILED! Error " + vErrCode;
    return vResult;
    } // method: doTestDbConnectionViaLdap
    -- ========================================================================================
    function do_test_db_connection_via_ldap
    pi_db_conn_url IN VARCHAR2,
    pi_user_name IN VARCHAR2,
    pi_user_password IN VARCHAR2
    return VARCHAR2
    is -- PRIVATE to the net_services package
    language java -- NOTE: See cr_java_class_NetServices.sql for actual java implementation
    name 'NetServices.doTestDbConnectionViaLdap
    ( java.lang.String, java.lang.String, java.lang.String ) return java.lang.String ';
    -- ========================================================================================
    function test_db_connection_via_ldap
    pi_net_service_name IN VARCHAR2,
    pi_user_name IN VARCHAR2,
    pi_user_password IN VARCHAR2,
    pi_search_base IN VARCHAR2
    return VARCHAR2
    is -- PUBLIC procedure
    v_url      VARCHAR2(256);
    begin
    g_err_source := 'NET_SERVICES.test_db_connection_via_ldap';
    g_err_action := 'build_jdbc_conn_url_using_oid';
    /*     NOTE: We don't want to assert the parameters because we don't want to raise
    an exception;
    -- Get the jdbc connection url that uses oid info
    v_url := build_jdbc_conn_url_using_oid( pi_net_service_name, pi_search_base );
    return( do_test_db_connection_via_ldap( v_url, pi_user_name, pi_user_password ) );
    end test_db_connection_via_ldap;
    -- ========================================================================================
    Thanks in advance for your consideration.
    Troy

    Troy:
    You could be right in your guess that the error is related to MTS. Search Metalink for '16371'. Why not switch your APEX app to use OHS and test whether the error persists. ?
    varad

  • Call a function inside a package from a stored procedure

    Hello:
    I am kind of new to the stored procedure. Does anyone know how to call a function inside a package from another stored procedure?
    I have a existing function (func_b) inside a package (pack_a) and it returns a cursor. I want to call this function from a stored procedure (proc_c) so that I use the data inside the cursor.
    can I do the following in proc_c:
    my_cursor1 SYS_REFCURSOR;
    begin
    my_cursor1 := exec pack_a.func_b
    end
    It will be very helpful if anyone can point me to any reading or example. Thank you very much for your information.

    guys:
    Thank you for your information so far. I need some more help here. I was able to run the function in my stored procedure. However, I was not able to print the result on the screen to view the cursor result, although I am using dbms_output.put_line statement inside my stored procedure.
    I use the following statement to execute my stored procedure on sql*plus. I can tell the stored procedure is executed successfully, but I did see anything printed:
    DECLARE TEMP VARCHAR2(100);
    BEGIN PROC_LAWS_CAD_NAME_SEARCH('LPD', 'TEST DEVICE ID', 'TEST LAST NAME', 'TEST FIRST NAME', 'F', '11112009', TEMP); END;
    I tried to use 'set serveroutput on' and got the following error:
    ERROR:
    ORA-06502: PL/SQL: numeric or value error: host bind array too small
    ORA-06512: at line 1
    I am kind of confused now. thank you for your help.
    Jack
    Here is my procedure:
    create or replace
    PROCEDURE PROC_SEARCH
    ( AGENCY_ID IN VARCHAR2,
    DEVICE_ID IN VARCHAR2,
    L_NAME IN VARCHAR2,
    F_NAME IN VARCHAR2,
    SEX IN VARCHAR2,
    DOB IN VARCHAR2,
    CAD_NAME_SCH_RESULT_STR OUT VARCHAR2)
    AS
    v_agy_id varchar2(10);
    v_device_id varchar2(20);
    v_l_name varchar2(25);
    v_f_name varchar2(15);
    v_sex varchar2(1);
    v_dob date;
    -- this cursor is going to be used to store a list of warrant matching
    -- name search criteria
    cad_srch_cursor sys_refcursor;
    objSrch SEARCH_RESULT_TEMP%ROWTYPE;
    BEGIN
    cad_srch_cursor := SEARCH_PKG.SEARCH('TESTING', 'TESTER', null, null,null, null, getPhonetic('TESTING'));
    LOOP
    FETCH cad_srch_cursor INTO objSrch;
    EXIT WHEN cad_srch_cursor%NOTFOUND;
    --insert into SEARCH_RESULT_TEMP (name_last) values (objSrch.name_last);
    CAD_NAME_SCH_RESULT_STR := objSrch.name_last;
    dbms_output.put_line('First:'||objSrch.name_first||':Last:'||objSrch.name_last||':Middle:'||objSrch.name_middle);
    end LOOP;
    END PROC_LAWS_SEARCH;
    -----------------------------------------

  • Using PostLVUserEvent function from Labview.dll

    I am trying to use the PostLVuserEvent function from the labview.dll and corresponding extcode.h file.  I have made my own dll using CVI that uses this function.  I then use Labview to call my dll.  My dll compiles fine.  No issues, no errors.  LabView can call my dll function containing the PostLVUserEvent function with no errors.  However, the event number LabView passes my dll is not the same event number I receive so no LabView event is triggered. 
    Has anyone had this issue? 
    We are trying to solve it from the LabView side and the CVI side but cannot seem to get it to work.  The examplesI have found here were compiled using C++ and those seem to work.  I do not know why when I compile my program in C, it creates the dll but does not work.   If I had to guess, i think it's an issue with pointers vs non-pointers.  When the LAbview program selects my function from the dll, it shows the argument PostLVUserEvent as a pointer when in my dll, it is not a pointer PostLVUserEvent....
    Any ideas?
    Thanks in advance. 

    Hello Blue
    Take a look to this one, it was created on C, I think the .c and the .h files will give a good idea, how the function should be implemented. It is important when calling the dll on LabVIEW, to use the std calling convention and run it on the UI thread.
    Regards
    Mart G
    Attachments:
    LabView EventTest.zip ‏1041 KB

  • Can I open a excel file from labview

    I have a program who write temperature in a excel file and i want to open this file from labview .

    This depends slightly on the amount of data you have stored within Excel.
    You can use the "Labview Functions>>FileIO>>Read from Spreadsheet file.vi" which effectively reads all lines from a text file and converts it into a numeric array.
    Alternatively, if your data structure in Excel is more complex than this, you can use ActiveX calls to Excel to retrieve it.
    Use an "ActiveX>>Automation Refnum" control and select the Excel server class. This will then enable you to access properties and methods of Excel to retrieve data from specific cells and pages.
    The attached example should help.
    Dan
    Attachments:
    Excel_Automation.vi ‏60 KB

  • Calling stored procedure from Java raises ORA-1722 exception

    Hi,
    As the title says, when I call the stored procedure from java I got the exception ORA-1722 (invalid number) but I've checked and rechecked my procedure on SQL-Developer and It's alright it works nice and clean !
    What's happening? is there something I'm missing?
    The way I call the stored procedure is:
        public void execProcedure(String procedure) {
            CallableStatement cs;
            try {
                cs = conn.prepareCall(procedure);
                cs.execute();
            } catch (SQLException ex) {
                Logger.getLogger(Database.class.getName()).log(Level.SEVERE, null, ex);
         where
        String procedure = "{call validateinfo}"I really need help on this, it's frustraiting me 'cause I need to finish a system but this little big problem is killing me ...
    Thanks any advice is very welcome :)

    Thanks for your help. Haven't tested the SP with a DB access client... which one do you recommend to use?
    The SP is the following:
    create or replace
    PROCEDURE validateInfo IS
      var number;
    BEGIN
      UPDATE temp_desarrollo
      SET status = '1';
      COMMIT;
      // Some string validations ...
      //This one just checks if the value of "monto" is a number
      //This update goes good
      UPDATE temp_desarrollo tmp
      SET cve_status = Decode(cve_status, NULL, '15', cve_status||',15')
      WHERE IsNumber(tmp.monto) = 'F';
      COMMIT;*/
      //This one just checks if the value of "monto" is greater than 0
      //if not, change de add to cve_status an errorValue
      UPDATE temp_desarrollo tmp
      SET cve_status = Decode(cve_status, NULL, '14', cve_status||',14')
      WHERE (cve_status NOT LIKE '%15%' OR cve_status IS NULL)
      AND to_number(tmp.monto) <= 0;
      COMMIT;
      //More string validations
      EXCEPTION
        WHEN OTHERS THEN
          var := SQLCODE;
          insert into excepciones values(to_char(var));
    END;I've deleted much code from the SP since I know there's nothing to do with the excepcion, just that UPDATE statement is the one giving me the exception.
    If those two UPDATES statements work with the same field (monto) why the first one is succeding and the second one not?
    Cheers,
    Federico
    P.S. the "isNumber" function is as follows, just in case.
    create or replace
    function IsNumber(val1 varchar2) return varchar2 is
      n number := null;
    begin
      n := to_number(val1,'9999999999999999.99');
        return 'T';
      exception
        when others then
          return 'F';
    end;

  • Controlling Tera Term from labview

    Hi guys
    In my new project I would like to send commands to Tera Term Pro. Tera Term then responds to the commands from Labview the same way as I would type the commands directly into Tera Term.
    I'm able to use cmd.exe with the SystemExecute Vi, but for my program I would like to do the same with Tera Term.
    I would like to send commands with a stringcontrol and get the respond in a string indicator, all in labview. Tera Term should run invisible in the background.
    So for this I thought using ActiveX would be the best. I have downloaded tera term pro.
    In Labview I create this from the ActiveX Palette and select browse on the ActiveX Class.
    In the Tera Term folder I find many .dll's:
    I have tried to open them all, but I only get this message:
    Does this mean it's impossible to use Tera Term with Labview like I described?
    I'm not so familiar with ActiveX, only with Excel (which is in the ActiveX Class list), so I might have missed something.
    My goal was to create a sub-vi which does the communication with Tera Term, the same way SystemExecute VI is built.
    Regards,
    Even
    Regards,
    Even
    Certified LabVIEW Associate Developer
    Automated Test Developer
    Topro AS
    Norway
    Solved!
    Go to Solution.

    Sorry for this late reply. I have been using Teraterm Macro (not Teraterm Pro serial terminal) to interface with my previous provisioning app written in LabVIEW.
    Teraterm Macro is such a lifesaver in that it can easily interface with your development boards that need: (1) RS-232C, (2) FTP, (3) TFTP or (4) SSH connections. The plain-vanilla 'serial' VI's are just that - serial port only and those need additional code to work reliably. If you need a good serial port VI try Prabhakant Patil's Hyper Terminal for LV 2009 and newer. You will find an ZIP or VIPM package from LAVA (lava.org). I have used his versions countless of times and is 10x more reliable than provided in LV examples.
    You will indeed use the System-Exec.VI to call Teraterm Macro since *sigh* no one has written a wrapper for the DLLs (as you mentioned they are built for .Net framework. I have talked with the current developers and they are willing to give anyone the pass to extend Teraterm for LabVIEW so C++ devs out there with good LabVIEW knowledge should re-build the DLLs as static libraries that can be called from within LabVIEW. For now, this is the only way and it is a kludge - but it works - just not in a way you expect.
    Here you can see that I am building the command line arguments before I call the system-exec node. Refer to the excellent how-to instructions at:
    http://ttssh2.sourceforge.jp/manual/en/macro/commandline.html
    Teraterm Macro will be spawned (opened) like it would when called from the command line. Its std input & output are not tied to your VI. You can merely pass arguments to the system-exec node. This is the reasons why we need someone to recompile the Teraterm Macro DLL as a static library (anyone?) so we can build a wrapper VI around the functions. Then its std inputs and outputs can be tied to LabVIEW's controls and indicators - hence, it becomes LV native.
    -Relativity

  • I am using Activex controls from Labview to log the data into Excel spreadshee​t. My applica

    tion is running fine without giving any error messages. But even after the vi stops, excel process does not shutdown. "Excel.exe" process keeps running until I end it from Windows NT Task Manager. Is there any way to end the excel.exe process from Labview?

    tion is running fine without giving any error messages. But even after the vi stops, excel process does not shutdown. "Excel.exe" process keeps running until I end it from Windows NT Task Manager. Is there any way to end the excel.exe process from Labview?I use Excel Active X control frequently to save and then analysis test data. In order to properly destroy the "Excel.exe" process it is important to close all the automation refnums opened when using the Excel active x controls. After completing your desired Excel task wire all the refnums in reverse order they were created into the Automation Close function in Functions->Communication->Active X pallette. This includes all Application, Workbook, Worksheet, or Range refnum. Missing even one of these refnums will mean that Excel.exe will still persist in the task manager and cause problems when excel is opened from outside LabVIEW. I hope this helps.
    Stephan

  • Missing Function

    I have recently upgraded from labview 6 to 7. One of the new features that liked is the “Highlighting Execution” function. This is available with new labviews I make up but the function is missing for labviews created in six and converted to seven as well as the single step run features. Are the available but just not on the tool bar or are they not available because the program was converted from seven.

    You might want to post this on the LabVIEW forum. Someone might be able to help you there.
    Bilal Durrani
    NI

  • How can i update an html web page from Labview?

    I intend to publish the "status" of an experiment online through an web page. I mean, if my vi is running i would like to have a phrase or indicator set on at my web page. If my Vi is not running i would like this indicator set off. This page is hosted in a server and I would like to know if its possible to update the html file from labview through an ftp connection.
    Thanks in advance...
    MSc. Alexandre Michel Maul
    Parana Federal Univeristy - Brasil

    The system exec function is on the Communication palette. Its for executing system commands. On my Win2K system, the help for FTP is:
    "Ftp
    Transfers files to and from a computer running an FTP server service (sometimes called a daemon). Ftp can be used interactively. Click ftp commands in the Related Topics list for a description of available ftp subcommands. This command is available only if the TCP/IP protocol has been installed. Ftp is a service, that, once started, creates a sub-environment in which you can use ftp commands, and from which you can return to the Windows 2000 command prompt by typing the quit subcommand. When the ftp sub-environment is running, it is indicated by the ftp command prompt.
    ftp [-v] [-n] [-i] [-d] [-g]
    [-s:filename] [-a] [-w:windowsize] [computer]
    Parameters
    -v
    Suppresses display of remote server responses.
    -n
    Suppresses autologin upon initial connection.
    -i
    Turns off interactive prompting during multiple file transfers.
    -d
    Enables debugging, displaying all ftp commands passed between the client and server.
    -g
    Disables file name globbing, which permits the use of wildcard characters (* and ?) in local file and path names. (See the glob command in the online Command Reference.)
    -s:filename
    Specifies a text file containing ftp commands; the commands automatically run after ftp starts. No spaces are allowed in this parameter. Use this switch instead of redirection (>).
    -a
    Use any local interface when binding data connection.
    -w:windowsize
    Overrides the default transfer buffer size of 4096.
    computer
    Specifies the computer name or IP address of the remote computer to connect to. The computer, if specified, must be the last paramete
    r on the line."
    I use tftp all of the time to transfer files in a similar manner. Test the transfer from the Windows command line and copy it into a VI. Pass the command line to system exec and wait until it's done.

  • What is the easiest way to open an application from Labview?

    I need to open an application from labview and depending on a user's selection, load one out of a group of files for the application that is opened. I need to know what is the best or easiest way to open an application and load a file that is used by the application based on a selection.

    Here is the response that I got from Cognex when I asked them about how to do this. Do you understand what they are talking about?
    In order to do something like this you will probably want to look into the Display Control/SDK for In-Sight. The Display Control gets installed along with In-Sight Explorer and includes a control that can be used in an environment like Labview to communicate with In-Sight sensors while the SDK is an enhanced version of the Display Control that gives you more control and functionality. I am not very familiar with the Labview environment so I will give some code snippets in VB.Net and hopefully you can adjust them as necessary. Specifically I see 3 possible avenues to do this:
     1) Using the Display Control you have access to many of the dialog boxes that are used in In-Sight Explorer including the Load Job dialog box. You can spawn this dialog box through a line of code similar to cvsInSightDisplay1.Edit.OpenJob.Execute(). I am not certain if the Labview environment will be able to spawn and display this dialog though. 2) With the addition of the SDK (additional purchase) you can directly access sensor properties including the job. There is a method called LoadJobFile to load jobs from on the sensor and LoadJobFileLocally to load jobs from the host machine. A typical line of code might be cvsInSightDisplay1.InSight.File.LoadJobFile("myjob1.job").3) If Labview cannot handle the dialogs and the SDK is not an option for you then you may still be able to do this using Native Mode commands. Native Mode commands are sent through a socket on the telnet port (typically port 23). Keep in mind that you will need to handle the username/password prompt and response when you first open the socket before issuing any Native Mode commands. The command to load a job file from the sensor would be the Load File command which would be a string similar to "LF myjob1.job". The Native Mode commands are documented in the In-Sight Explorer help file. 

  • Call a pl/sql stored procedure from a report link

    Hello everyone:
    I have a report with a link in a column, which takes you to another page and passes values to that page, but also need the link, run a stored procedure before going to the other page.
    In the Forum I found cases similar to this, but none of the examples is clear to me how I do this. It seems that the target of the link should be URL, and also I have to call the stored procedure with a javascript function.
    My questions are:
    - Is this the best method to make what I need?
    - How should be the syntax of the link that takes me to another page and run the "stored procedure"
    - How and where I put the function "javascript" to run the "stored procedure"
    BDD: Oracle 11 g
    Apex version 4.1
    Best regards
    Gerard

    Hi,
    Change the link to call an apex.submit process. (javascript).
    Edit:
    I've set up a basic example.
    Region 1 (just so you can see the value getting set):
    select :P27_HIDDEN item_Value
    from dual
    Region 2:
    select rownum id, dbms_random.string('U', 12) sss
    from dual
    connect by level <= 20
    item attributes for ID:
    Target: URL
    URL: javascript:apex.submit({request:'NAVIGATE', set:{'P27_HIDDEN':#ID#}});
    (P27_HIDDEN is just a hidden item i created)
    http://apex.oracle.com/pls/apex/f?p=54920:27
    Edit2:
    In your case, then you can just have a page process based on conditions request = expression1, expression1: NAVIGATE..... then a page branch to go to the desired page, also with the same conditions
    Edit3:
    Im not sure what examples you are referring to , as you didn't supply any links; but you mention calling the stored procedure from javascript, so would likely involve some AJAX, but imo not necessary.

  • How do you use the windows User32.dll Library functions to read variables from other applications that are running

    I am trying to read a text box from a programme running at the same time as my Labview application using calls to the Windows
    User32.dll. I believe I need to find the window handle for the 'form' containing this text string and use this together with
    various other defined input variables to access the sting.
    I have no experience of using this 'Call Library Function Node', but have an understanding of the 'C' programming language. Does anyone have
    example Labview code showing how this might be done.
    Thanks

    If you're trying to access information that's being displayed in the window of another application and that application has no ActiveX interface, then yes, Windows calls can be used. There's a very good example on calling DLLs that ship with LabVIEW. Open the Example Finder (Help->Find Examples) and switch to the Search tab. Enter "Call" in the search box and open the VI "Call DLL". Run the VI, select any of the examples, and click the "Open Example VI..." button. That shows you how to call a DLL.
    Now, given that you have no experience in calling DLLs, have only an "understanding" of C (which to me means you have never written something like a DLL), and don't seem to know that much about what Windows functions you may need, you're going to find this route pretty difficult, especially since you have to deal with Windows API calls, which are not always that easy to do from LabVIEW.
    Let me propose an alternate solution. Go over to http://www.autoitscript.com/autoit3/ and download AutoIt. This is an automation tool that allows you to automate just about anything you want. It has an ActiveX interface that you can call from LabVIEW. I've attached an example VI that shows you how to use it to get the value of a text box from one of the tabs in the computer "System Properties" control panel applet.
    Attachments:
    AutoIt Example (v7).vi ‏25 KB

Maybe you are looking for

  • Live! Cam Voice (mic not working)

    Just bought Live! Cam Voice yesterday. Mic still not working properly even after verifying the installation. Please advise how to rectify. Thanks,

  • No GPU Acceleration or MPE benefit (FX3800)

    Yikes Installed CS5  (Full Paid Version) yesterday.  Shaking it down today. Everything is working at light speed except..... I do not get any GPU Acceleration or MPE benefit from the QUADRO FX3800 (or PPRO). As soon as I apply any GPU accelerated  ef

  • TM not let me back up a 32GB flash drive?

    I would like to back up a 32 GB flash drive in addition to my hard drives via Time Machine - but TM won't let me remove the device from its excluded list??  Am I doing something wrong here?  Please advise.

  • Where is the "quick fix" for the "insuffient data" bug in 9.5.2?

    Adobe alludes to a quick fix for this acknowledged but says contact a support team to request it. Please consider this a request that the fix be PUBLISHED for all. Thank you.

  • Burning Issue: Weird

    OK: I have zero problems burning... except when I try to burn anything by the Yeah Yeah Yeahs. I've downloaded 3 songs and whenever I put those specific songs into a playlist, it freezes I Tunes when I try to burn it. I can't convert the songs either