Need help in file content conversion complex structure

Hi Guys ,
Iam new to this file content conversion , Please let me know whether below requirement is possible .if yes than how ?
Inbound XML file from Proxy
<Data>
  <keyfield1>0011</keyfield1>
  <keyfield2>0012</keyfield2>
  <Keyfield3>0013</Keyfield3>
  <field1>Test1</field1>
  <field2>testfield1</field2>
  <field3>0001</field3>
<Data>
  <keyfield1>0021</keyfield1>
  <keyfield2>0022</keyfield2>
  <Keyfield3>0023</Keyfield3>
  <field1>Test2</field1>
  <field2>testfield2</field2>
  <field3>0002</field3>
output pgp flat file .
pgp file format should be as below after file content conversion
  0011|0012|0013|Test1||||||
  0011|0012|0013|Testfield1||||||
  0011|0012|0013|0001||||||
  0021|0022|0023|Test2||||||
  0011|0012|0013|Testfield2||||||
  0011|0012|0013|0002||||||
thanks a lot .
Regards
Prabhu

Hi.
Try this.
First you need to use a message mapping  and create a target structure to convert a similar output  structure that do you want.  like this
<Target>
--  Field1
--  Field2
--  Field3
--  Field4
--  Field5
--  Field6
--  Field7
--  Field8
--  Field9
</Target>.
Then map
keyfield1-> Field 1 ,keyfield2-> Field 2 , keyfield 3---> Field 3
map  field1-> field4 .. for the others fields duplicate the Target node (right click)  and  map map  field2-> field5 ..etc.
For the field 5 until field 9 map with constant ("'')
Then in you receiver comunication channel put simple parameters. 
Target.fieldSeparator = |
Target.endSeparator = 'nl'
Regards.

Similar Messages

  • Help required File Content Conversion.

    Hi All,
    Kindly help me in this topic i.e. File Content Conversion.
    -  What is File Content Conversion?
    -  Is knowledge of any programming language required?
    -  What is its function?
    -  How do I use it?
    Thanks in Advance.
    Regards,
    Sreedhar, Av

    Hi Sreedhar,
    Reward points if this helps
    What is File Content Conversion?
    File content conversion is used for converting flat files (fixed lenght, comma seperated) into XML messages for further processing by an integration engine. The internal XI processing (mapping, routing etc) is based on XML messages hence you need messages to be converted to XML.
    SAP By default understands xml data structure. If your file is coming in an xml format you can process it as it is.
    In case of file that is coming with a delimiter then you need to have File content conversion for SAP adpater to conver file into an XML structure which will then go to next step of Message Mapping.
    Is knowledge of any programming language required?
    No
    What is its function?
    Check these blogs for content conversion,
    /people/arpit.seth/blog/2005/06/02/file-receiver-with-content-conversion
    /people/venkat.donela/blog/2005/06/08/how-to-send-a-flat-file-with-various-field-lengths-and-variable-substructures-to-xi-30
    *How do I use it? *
    http://help.sap.com/saphelp_nw04/helpdata/en/2c/181077dd7d6b4ea6a8029b20bf7e55/content.htm
    Reward points if this helps
    Regards
    Pragathi.

  • Sender File Content Conversion Complexity

    It is again time to dip into the well of knowledge that is SDN.
    I have a question about sender file content conversion.  
    It appears that I can only create simple XML structures with it, but I'm hoping someone here can help.
    Lets says I have a file where each record layout is the same.   There are not header records, trailer records, etc.   Basically only one structure within the recordset.
    However the record itself may have a complicated structure.   For example, the layout of each record may be:
    String1, String2, String3, Array(0:3) consisting of String4, String5, String6.
    Can I convert that to a structure of
    <Node>
        <string1>
        <string2>
        <string3>
        <array>
            <string4>
            <string5>
            <string6>
        <array>
            <string4>
            <string5>
            <string6>
    </Node>
    Or must I create a DT containing one node giving string4,5 and 6 a unique name for each occurance?
    Thanks in advance.

    Hi,
    You can go with generic structure and then either in the adapter module or Mapping, you can format the structure. Because content conversion has a limitation to upto one level.
    check this for limitation-
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/50061bd9-e56e-2910-3495-c5faa652b710
    check this for generic structure-
    /people/sravya.talanki2/blog/2005/08/16/configuring-generic-sender-file-cc-adapter
    Rgds,
    Moorthy

  • File Content Conversion - Recordset Structure required??

    Hi,
    I have a File Sender Communication Channel (CC) to convert very simple csv format to XI data type (XML).
    The contect of csv file will look something like this and will always have one line per file.
    111,222,333,444,555
    And I have defined the Data Type/Message Type with 5 fields as follows:
    Sender_DT
    ---F1
    ---F2
    ---F3
    ---F4
    ---F5
    Assuming that I'll always get one line of data in a csv file, I don't really need to set Recordset Structure in Content Conversion Paramters of File Sender CC but it is required parameter so you can't save it without populating this parameter.
    I understand that I can add a recordset to my DT so that it will look like below and type in Recordset in the Recordset Structure parameter but wanted to see if there is any other way to go around this without adding Recordset to DT.
    Sender_DT
    ---Recordset
    F1
    F2
    F3
    F4
    F5
    Thanks,
    Jay

    Hi Jay,
    You are correct. You can't have a struct like
    DT_SOURCE
    --F1
    --F2
    --F3
    You need another node with in DT_SOURCE like recordset
    DT_SOURCE
    -Recordset
    --F1
    --F2
    --F3
    If you don't get multiple lines in source file, you can simpl set the Recordset occurance to 1..1 but it is mandatory.
    Regards,
    Jai Shankar

  • File Content Conversion : Recordset Structure with * not reading file

    Hallo all,
    we have the following problem.
    we implemented a scenario as sown in this blog
    /people/venkat.donela/blog/2005/06/08/how-to-send-a-flat-file-with-various-field-lengths-and-variable-substructures-to-xi-30
    but there is a problem.
    If the file structure is declared as :
    Header,1,Items,*
    then the adapter does not even read the file from the directory (so I assume that for some reason the file structure is not as expected).
    If on the other had the structured is declared as :
    Header,1,Items,3
    everything works.
    Obviously though, this is not satisfying since we need variable cardinalities.
    Here is an example :
    I have a specific file in a standard directory, called xi_input.
    The file is edited straight into that directory, so there can't be filename errors etc.
    If the file is left empty :
    Nothing happens . No message of any kind in sxmb_moni/monitoring xml messages .
    If the file contains the following (data is random) , where 'H' is the key for the header and 'I' is the key for the items :
    H 20060403 16 3 316001 kapou lalla morellala 20060403 F3 23
    I 277101010 2
    I 277101011 3
    I 277101012 4
    There are to cases :
    if the file structure is declared as :
    Header,1,Items,*
    Then nothing happens .
    If on the other had the structured is declared as :
    Header,1,Items,3
    everything works .
    Any suggestions and help is appreciated
    Thank you .

    Actually yes, there is an error message :
    Error     5/30/08 3:12:45 PM     fda9d3c5-4775-4df8-17b8-dfd14191171d     
    Retry interval started. Length: 5.0 seconds
    Error     5/30/08 3:12:45 PM     fda9d3c5-4775-4df8-17b8-dfd14191171d     
    Could not archive file 'E:\tmp\NetBeauty\In\xi_input.dat' after processing
    5/30/08 3:12:45 PM           Processing started
    And the details are :
    2008-05-30 16:07:00     Success     Channel CC_File_adapter: Entire file content converted to XML format
    2008-05-30 16:07:00     Warning     Channel CC_File_adapter: Empty document found. Proceed without sending message
    2008-05-30 16:07:00     Error     Attempt to archive file "E:\tmp\NetBeauty\In\xi_input.dat" after processing failed. Retry
    Only that they don't look very helpful. From this I only understand that the data in my input.dat file is not in the format expexced.
    I Have configured key fields as :
    keyfield name : keyfield
    Header.fieldNames : keyfield,CreationDate,CentralCustomerCode,CustomerCode,ReferenceDocumentNumber,DeliveryPlace,Message,ReturnMessage,DeliveryDate,SalesmanCode,Rest
    Items.fieldNames : keyfield,Material,Quantity
    Header.keyFieldValue     "H"
    Items.keyFieldValue     "I"

  • File content conversion : Deep Structure

    Hi,
    I have to do a file conversion(receiver file adapter) of an xml file which has a structure
    <root>
    <header>
      <recordtype>H</recordtype>
    </header>
    <company>
      <recordtype>C</recordtype>
      <companycode>001</companycode>
      <detail>
       <recordtype>D</recordtype>
        <customer>c1</customer>
      </detail>
      <detail>
        <recordtype>D</recordtype>
        <customer>c2</customer>
      </detail>
    </company>
    <company>
      <recordtype>C</recordtype>
      <companycode>002</companycode>
      <detail>
       <recordtype>D</recordtype>
        <customer>c3</customer>
      </detail>
      <detail>
        <recordtype>D</recordtype>
        <customer>c4</customer>
      </detail>
    </company>
    <trailer>
      <recordtype>T</recordtype>
    </trailer>
    </root>
    I would like to convert it into
    H
    C001
    DC1
    DC2
    C002
    DC3
    DC4
    T
    This is what i put in the
    content conversion parameters..
    HEADER,COMPANY,DETAIL,TRAILER
    HEADER.fieldFixedLengths     1
    COMPANY.fieldFixedLengths     1,3
    DETAIL.fieldFixedLengths     1,2
    TRAILER.fieldFixedLengths     1
    the file adapter failed during conversion.
    I am just wondering if it is to do with the deep structures
    ANY THOUGTHS....

    what do you mean by target structure.the mapped structure or the final file that is written to the FTP Folder.
    the mapped structure is a treee
    <root>
    <header>
    <recordtype>H</recordtype>
    </header>
    <company>
    <recordtype>C</recordtype>
    <companycode>001</companycode>
    <detail>
    <recordtype>D</recordtype>
    <customer>c1</customer>
    </detail>
    <detail>
    <recordtype>D</recordtype>
    <customer>c2</customer>
    </detail>
    </company>
    <company>
    <recordtype>C</recordtype>
    <companycode>002</companycode>
    <detail>
    <recordtype>D</recordtype>
    <customer>c3</customer>
    </detail>
    <detail>
    <recordtype>D</recordtype>
    <customer>c4</customer>
    </detail>
    </company>
    <trailer>
    <recordtype>T</recordtype>
    </trailer>
    </root>
    with the company 1 to unbounded
    under which there can be multiple details...

  • File Content Conversion - nested structures

    In the above bolded  message ... 
    2 Records are repeating  for  multiple times..
    i know how to do..
    if its repeats like  below.. i know how to do..
    Record1
    Record1
    Record1
    Record1
    Record1
    Record1
    Record1
    Record2
    Record2
    Record2
    Record2
    Record2
    Record2
    Record2
    Record2
    But in my case its Records are repeating  in this way...
    Record1
    Record2
    Record1
    Record2
    Record1
    Record2
    Record1
    Record2
    Record1
    Record2
    Record1
    Record2
    Record1
    Record2
    Record1
    Record2
    Record1
    Record2
    can  some help me .. please.. 
    Thanks
    sagar
    Message was edited by: sagarkavi srungarakavi

    If each record type starts with a key, and it looks like they do, it shouldn't matter what order they are in.
    In the recordset structure just make sure both of those are set like: Record1,,Record2,
    Set the recordset sequence to variable.
    Fill in the key field name and type, and then use the keyFieldValue parameter below. 
    Record1.keyFieldValue PO1
    Record2.keyFieldValue PID

  • File content conversion for Pipe delimited file

    Hi
    i have a scenario ( file-xi-proxy) in whch file is coming in a pipe delimited.
    my data type is like
    DT_ XXXXX
    AwardInfo
    Header contains some fileds
    DetailRecord contains some fileds
    trailer contains some fields
    what are content conversion parameters i have to use
    venkat

    Sedamkar,
    Expecting you have one header, multiple details and one trailer then give recordset structure in sender file communication channel as:
    Header,1,DetailRecord ,*,trailer,1
    In content conversion you should give parameters:
    Header.fieldSeparator : |
    Header.endSeparator : 'nl'
    DetailRecord.fieldSeparator : |
    DetailRecord.endSeparator : 'nl'
    trailer.fieldSeparator : |
    trailer.endSeparator : 'nl'
    You may need to change the parameters also according to your strcuture and the file layout. See this SAP help for file content conversion:
    http://help.sap.com/saphelp_nw04/helpdata/en/e3/94007075cae04f930cc4c034e411e1/content.htm
    http://help.sap.com/saphelp_nw04/helpdata/en/2c/181077dd7d6b4ea6a8029b20bf7e55/content.htm
    Regards,
    ---Satish

  • Issue w/ File content conversion (Receiver side)

    Folks, there seems to be an issue with the conversion. I've read several of threads on this forum, but none helped! Although the file is generated with 8 bytes there seems to be nothing in the file.
    However when 'File' message protocol is used, the xml file is generated correctly as expected. All my other settings are fine.
    Here is the scenario:
    1) created Message type -
    MTX
    ..Material
    ..BaseUnit
    ..MatGrp
    ..Division
    2) comm. channel created for -
    Transport protocol: File (NFS)
    Message protocol: File content conversion
    Recordset Structure: MTX
    parameters:
        MTX.fieldSeparator: ,
        MTX.endSeparator: 'nl'
    Should recordset struc. and parameters have 'ns0' prefix, i.e.,
    Recordset Structure: ns0:MTX
    parameters:
        ns0:MTX.fieldSeparator: ,
        ns0:MTX.endSeparator: 'nl'
    What esle is missing? any thoughts are welcome.
    Thanks and appreciate your responses.

    Hi ABAP JUNOON,
    Could you please create another Test scenario and
    try
    MTI_XXX
         - DATA(0..unbounded)
             - fields?
    i mean, without redundant RS(Record Structure).
    and use 
    Transport protocol: File (NFS)
    Message protocol: File content conversion
    Recordset Structure: DATA.
    it will written the complete output file.
    some people create the Reciver data type for  test scenario's as follows.
    MTI_XXX
       -RS
         - DATA(0..unbounded)
             - fields?
    i mean with redundant RS
    in this case file is generated, but nothing will be appear.
    so plz take care while creating the reciver data type with FCC.
    and the following case also will work i.e
    MTI_XXX
       -RS
         -Header(0,1)
             - fields?
         - DATA(0..unbounded)
               - fields?
         - Trailer(0,1)
             - fields?
    Regards
    Mahesh.

  • File content  conversion is not creating the exact strcuture as Datatype

    Hi,
    We are facing issue .
    I have  sender DT type
    <FIle_DT>
    < HeaderDetail>
          <Field1>
            <Field2>
                          <Linietemdetails>
                                                        <Field1>
                                                    <Field2>
    </Linietemdetails>
    </ HeaderDetail>
    </File_DT>
    but when I am preocessing  the file content conversion - > when its pulling the data  from  the file this structure become
    <FIle_DT>
    < HeaderDetail>
          <Field1>
            <Field2>
    </ HeaderDetail>
                         <Linietemdetails>
                          <Field1>
                          <Field2>
                      </Linietemdetails>
    </File_DT>
    I want  same  above one after content conversion. I tired allt he options availble . please  help
    In file content conversion   I give 
    RecordSet Structure -->HeaderDetail,,LineItemDetail,
    HeaderDetail.keyFieldValue     H
    HeaderDetail.endSeparator     'nl'
    HeaderDetail.fieldFixedLengths     1,4,8,25
    HeaderDetail.keyFieldInStructure     ignore
    LineItemDetail.keyFieldValue     L
    LineItemDetail.endSeparator     'nl'
    LineItemDetail.fieldFixedLengths     1,3,1,10,10,24,3,25
    LineItemDetail.keyFieldInStructure     ignore
    LineItemDetail.keepIncompleteFields     YES
    ignoreRecordsetName     true
    Please help
    regards
    Ram

    Hi Babu,
    Thanks a lot for your input.
    Actually My requirement is this its file to Multiple idoc scenarios.
    Here I am getting flat file HeaderDetails and LinItemdetails. its having Multiple Headerdetail then Line Item Details, I want to create idoc  for each HeaderDetail and all the Next LineItemdetails should go to that IDoc.  If we can find some solution then it will also  work for me.
    For ex.
    My source would be
    FIle_DT>
    < HeaderDetail1>
    <Field1>
    <Field2>
    </ HeaderDetail>
    <Linietemdetails11>
    <Field1>
    <Field2>
    </Linietemdetails11>
    <Linietemdetails12>
    <Field1>
    <Field2>
    </Linietemdetails12>
    < HeaderDetail2>
    <Field1>
    <Field2>
    </ HeaderDetail>
    <Linietemdetails21>
    <Field1>
    <Field2>
    </Linietemdetails21>
    <Linietemdetails22>
    <Field1>
    <Field2>
    </Linietemdetails22>
    < HeaderDetail3>
    <Field1>
    <Field2>
    </ HeaderDetail>
    <Linietemdetails31>
    <Field1>
    <Field2>
    </Linietemdetails>
    </File_DT>
    I want target structure like this .
    <Idoc>
    <HeaderDetail1>
    <LineItemdetail11>
    <LineItemdetail12>
    <LineItemdetail13>
    </Idoc>
    <Idoc>
    <HeaderDetail2>
    <LineItemdetail21>
    <LineItemdetail22>
    <LineItemdetail23>
    </Idoc>
    <Idoc>
    <HeaderDetail3>
    <LineItemdetail31>
    </Idoc>
    If anyway you can help me how to go and how to do this grouping then it would be really great for me.
    regards
    ram

  • File content conversion using SOAP adapter

    Hi,
         I'm using a receiver SOAP adapter in my IDOC to file scenario and need to do file content conversion in the receiver side.
    Are any standard modules available for file content conversion in the SOAP adapter or do I need to write custom EJB modules for this.
    Please note that I have to use a SOAP adapter, can't use any other adapter.
    Thanks in advance
    Shiladitya

    Hi,
    XML Document Conversion Type
    &#9679;      Enter recordTypes as the parameter name.
    Under Parameter Value, enter the complete, comma-separated list of all names of recordset types that occur in the document to be converted.
    If you decide to use this method, you can define a different conversion type for each recordset type that occurs in the XML document.
    For example, you could name the recordset types as follows: RecordType1,RecordType2,RecordType3.
    &#9679;      Enter singleRecordType as the parameter name.
    Under Parameter Value, enter the name of a recordset type that is to be used to convert all elements that occur in the XML document.
    If you decide to use this method, define the same conversion type for each recordset type that occurs in the XML document.
    You must enter exactly one parameter only. Whichever parameter you choose, you automatically exclude the second parameter.
    You define further parameters for each recordset type.
    In the remainder of this documentation the parameters are specified by the prefix <RecordType>. In your configuration, replace this name with the name of the recordset type.
    Conversion Type List with Separators
    &#9679;      <RecordType>.fieldSeparator
    Enter the field separator that is written between the individual fields of a record.
    This specification is mandatory.
    Conversion Type List with Fixed Field Length
    &#9679;      <RecordType>.fieldLengths
    Specify a character string that contains a list of fixed field lengths that are separated by commas and which determines the number and the length of fields generated in the text file.
    For example, you want to write a recordset with three elements that have field widths of five, ten, and fifteen characters. Enter:
    <RecordType>.fieldLengths = 5,10,15
    This specification is mandatory.
    &#9679;      <RecordType>.fieldLengthExceeded
    Specify how you want to handle fields that exceed the configured field length. Permitted values for the parameter value are:
    &#9675;       error (default)
    Interrupts processing of message with error
    &#9675;       cut
    Cuts off superfluous characters
    &#9675;       ignore
    Ignores the field length restriction
    Further Entries
    &#9679;      <RecordType>.beginSeparator
    Enter a string. The string is placed in front of the first field of a recordset.
    &#9679;      <RecordType>.endSeparator
    Enter a string. The string is appended to the last field of a recordset as a concluding character. The default is \r\n.
    &#9679;      contentType
    Enter the MIME type of the converted payload. The default value is text/plain.
    &#9679;      addHeaderLine
    Only define this parameter if you have already defined singleRecordType.
    Define whether a header line is to be added to the result of the conversion.
    &#9675;       none (default)
    Does not insert a header line
    &#9675;       fromXML
    The header line is generated from the element name of the first recordset of the XML document
    &#9675;       fromConfiguration
    The header line is determined by the configuration parameter headerLine.
    &#9679;      headerLine
    Only define this parameter if you have already set addHeaderLine=fromConfiguration.
    The value that you define is placed in front of the result of the conversion as a header line.
    &#9679;      fixedLineWidth
    Enter the maximum line length n (in characters) that can be written to the resulting document. The separator specified by lineSeparator is inserted in the resulting document every n characters.
    &#9679;      lineSeparator
    Only define this parameter if you have already defined fixedLineWidth.
    Specify the string that is written to the resulting document at the end of each line that is written with fixedLineWidth. The default is \r\n.
    Use of Special Characters
    You can use special characters in the following parameters: <RecordType>.fieldSeparator, <RecordType>.beginSeparator, <RecordType>.endSeparator, headerLine, and lineSeparator.
    &#9679;      Tabulator: \t
    &#9679;      Carriage Return (CR): \r
    &#9679;      Line Feed (LF): \n
    &#9679;      Arbitrary character: \x<code>
    <code>indicates the hexadecimal character code of the character to be displayed.
    Regards,
    Phani

  • Doubt regarding file content conversion Recever File adapter.

    target structure.
    <?xml version="1.0" encoding="UTF-8"?>
    <ns1:MT_ChangeOfAddress xmlns:ns1="urn:passhe.com/ChangeOfAddressISA28">
         <BUSINESS_PARTNER>
              <item>
                   <CAMPUSCODE>65</CAMPUSCODE>
                   <STUDENTNUMBER>6500000192</STUDENTNUMBER>
                   <ST_OBJID>732298498</ST_OBJID>
              </item>
         </BUSINESS_PARTNER>
    </ns1:MT_ChangeOfAddress>
    target structure is look like this.
    MT_ChangeOfAddress
         BUSINESS_PARTNER  (1,1)
              item       (0 to unbounded)
                  CAMPUSCODE (0,1)
                  STUDENTNUMBER (0,1)
                        ST_OBJID      (0,1)
    I have given below parameters in recever file adapter (file content conversion)
    Recordset Structure : item
    item.fieldNames  : CAMPUSCODE,STUDENTNUMBER,ST_OBJID
    item.fieldSeparator: , (comma)
    i am getting first two digits in my output file: that  file has only first two digits that is : 65
    may i know how hould i define file contente conversion recever adapter to get proper data in file adapter.
    thanks,s
    Dhanush

    Hi,
    Go through these blogs:
    /people/venkat.donela/blog/2005/03/02/introduction-to-simplefile-xi-filescenario-and-complete-walk-through-for-starterspart1
    /people/venkat.donela/blog/2005/03/03/introduction-to-simple-file-xi-filescenario-and-complete-walk-through-for-starterspart2
    /people/anish.abraham2/blog/2005/06/08/content-conversion-patternrandom-content-in-input-file
    /people/shabarish.vijayakumar/blog/2005/08/17/nab-the-tab-file-adapter
    /people/venkat.donela/blog/2005/06/08/how-to-send-a-flat-file-with-various-field-lengths-and-variable-substructures-to-xi-30
    /people/anish.abraham2/blog/2005/06/08/content-conversion-patternrandom-content-in-input-file
    /people/shabarish.vijayakumar/blog/2005/08/17/nab-the-tab-file-adapter
    /people/jeyakumar.muthu2/blog/2005/11/29/file-content-conversion-for-unequal-number-of-columns
    /people/shabarish.vijayakumar/blog/2006/02/27/content-conversion-the-key-field-problem
    /people/michal.krawczyk2/blog/2004/12/15/how-to-send-a-flat-file-with-fixed-lengths-to-xi-30-using-a-central-file-adapter
    /people/arpit.seth/blog/2005/06/02/file-receiver-with-content-conversion
    Thanks,
    Satya

  • Need Help in Sender File Content Conversion

    Hi All,
    I request your expert advice on Sender File content Conversion. I need to process the below pasted file. I was able to achieve this by keeping a offset of 6 in Sender PI File Adapter (PI 7.1) to ignore first 6 lines and used a Unix script to remove last line"END OF REPORT".
    Now my new requirement is I need to capture the date "DECEMBER 2009" from line 3. How can I do this. I have set offset as 6 so Adapter will start processing from line 7. If I don't set offset Interface fails. Please suggest. Thank you.
    ABC LAB            XYZ LIMITED"
                       TRIAL BALANCE"
                       FOR THE PERIOD ENDED DECEMBER 2009"
    "TEST Bank","101000",-1589365.58,0.00,738295.08,0.00
    "TEST Bank Clearing A/c","101200",0.00,0.00,14848018.55,0.00
    "TEST Bank Sweeps","101250",104315957.19,0.00,7571985482.08,0.00
    "TEST Receipts","101260",0.00,0.00,19788596.15,0.00
    "TEST Corporate Deposits","101270",-7776629.87,0.00,-135914980.50,0.00
    "SHARES","00SH",0.00,0.00,-7869890086.22,0.00
    "END OF REPORT"

    Dear Phani,
    Please go through the below blogs:
    File content conversion sites
    /people/venkat.donela/blog/2005/03/02/introduction-to-simplefile-xi-filescenario-and-complete-walk-through-for-starterspart1
    /people/venkat.donela/blog/2005/03/03/introduction-to-simple-file-xi-filescenario-and-complete-walk-through-for-starterspart2
    /people/arpit.seth/blog/2005/06/02/file-receiver-with-content-conversion
    /people/anish.abraham2/blog/2005/06/08/content-conversion-patternrandom-content-in-input-file
    /people/shabarish.vijayakumar/blog/2005/08/17/nab-the-tab-file-adapter
    /people/venkat.donela/blog/2005/03/02/introduction-to-simplefile-xi-filescenario-and-complete-walk-through-for-starterspart1
    /people/venkat.donela/blog/2005/03/03/introduction-to-simple-file-xi-filescenario-and-complete-walk-through-for-starterspart2
    /people/venkat.donela/blog/2005/06/08/how-to-send-a-flat-file-with-various-field-lengths-and-variable-substructures-to-xi-30
    /people/anish.abraham2/blog/2005/06/08/content-conversion-patternrandom-content-in-input-file
    /people/shabarish.vijayakumar/blog/2005/08/17/nab-the-tab-file-adapter
    /people/jeyakumar.muthu2/blog/2005/11/29/file-content-conversion-for-unequal-number-of-columns
    /people/shabarish.vijayakumar/blog/2006/02/27/content-conversion-the-key-field-problem
    /people/michal.krawczyk2/blog/2004/12/15/how-to-send-a-flat-file-with-fixed-lengths-to-xi-30-using-a-central-file-adapter
    /people/arpit.seth/blog/2005/06/02/file-receiver-with-content-conversion
    http://help.sap.com/saphelp_nw04/helpdata/en/d2/bab440c97f3716e10000000a155106/content.htm
    Please see the below links for file content conversion..
    /people/michal.krawczyk2/blog/2004/12/15/how-to-send-a-flat-file-with-fixed-lengths-to-xi-30-using-a-central-file-adapter - FCC
    /people/michal.krawczyk2/blog/2004/12/15/how-to-send-a-flat-file-with-fixed-lengths-to-xi-30-using-a-central-file-adapter - FCC
    File Content Conversion for Unequal Number of Columns
    /people/jeyakumar.muthu2/blog/2005/11/29/file-content-conversion-for-unequal-number-of-columns - FCC
    Thanks,
    Satya

  • Need File Content Conversion Help

    Hi,
       With the help of the SDNers i was able to create the proper structure for FCC.Now i want to have the column names been listed as part of the final file content.with the current structure i could get only the data and not the coulmnheaders
    The structure used is as below:
    Recordset structure=Root,Record
    Record.addHeaderLine=0
    Record.fieldNames=name,mobile,email
    Record.fieldSeparator=,
    Record.endSeparator='nl'
    Root.fieldSeparator=,
    Root.fieldSeparator='nl'
    Pls help me solve this.
    Regards,
    Karthik

    HI
    refer the following links
    File Content prameters for the Receiver Adapter
    http://help.sap.com/saphelp_nw04/helpdata/en/d2/bab440c97f3716e10000000a155106/frameset.htm
    File Content prameters for the Sender Adapter
    http://help.sap.com/saphelp_nw04/helpdata/en/2c/181077dd7d6b4ea6a8029b20bf7e55/content.htm
    Refer
    File Receiver with Content Conversion
    /people/arpit.seth/blog/2005/06/02/file-receiver-with-content-conversion
    Configuring the Receiver File/FTP Adapter
    http://help.sap.com/saphelp_nw04/helpdata/en/95/bb623c6369f454e10000000a114084/frameset.htm
    File content conversion sites
    http://help.sap.com/saphelp_nw04/helpdata/en/d2/bab440c97f3716e10000000a155106/content.htm
    Please see the below links for file content conversion..
    /people/michal.krawczyk2/blog/2004/12/15/how-to-send-a-flat-file-with-fixed-lengths-to-xi-30-using-a-central-file-adapter - FCC
    /people/michal.krawczyk2/blog/2004/12/15/how-to-send-a-flat-file-with-fixed-lengths-to-xi-30-using-a-central-file-adapter - FCC
    File Content Conversion for Unequal Number of Columns
    /people/jeyakumar.muthu2/blog/2005/11/29/file-content-conversion-for-unequal-number-of-columns - FCC
    Content Conversion (Pattern/Random content in input file)
    /people/anish.abraham2/blog/2005/06/08/content-conversion-patternrandom-content-in-input-file - FCC
    /people/harrison.holland5/blog/2006/12/20/xi-configuration-for-mdm-integration--sample-scenario - FCC - MDM
    XI in the role of a FTP
    /people/shabarish.vijayakumar/blog/2006/04/03/xi-in-the-role-of-a-ftp - FCC
    File to R/3 via ABAP Proxy
    /people/prateek.shah/blog/2005/06/14/file-to-r3-via-abap-proxy - FCC
    /people/mickael.huchet/blog/2006/09/18/xipi-how-to-exclude-files-in-a-sender-file-adapter - EOIO - File
    http://help.sap.com/saphelp_nw04/helpdata/en/ee/c9f0b4925af54cb17c454788d8e466/frameset.htm - cc
    http://help.sap.com/saphelp_erp2005vp/helpdata/en/95/bb623c6369f454e10000000a114084/content.htm - fcc cOUNTER
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/da1e7c16-0c01-0010-278a-eaed5eae5a5f - conversion agent
    File Content prameters for the Receiver Adapter
    http://help.sap.com/saphelp_nw04/helpdata/en/d2/bab440c97f3716e10000000a155106/frameset.htm
    File Content prameters for the Sender Adapter
    http://help.sap.com/saphelp_nw04/helpdata/en/2c/181077dd7d6b4ea6a8029b20bf7e55/content.htm
    Refer
    File Receiver with Content Conversion
    /people/arpit.seth/blog/2005/06/02/file-receiver-with-content-conversion
    Configuring the Receiver File/FTP Adapter
    http://help.sap.com/saphelp_nw04/helpdata/en/95/bb623c6369f454e10000000a114084/frameset.htm
    File content conversion sites
    /people/venkat.donela/blog/2005/03/02/introduction-to-simplefile-xi-filescenario-and-complete-walk-through-for-starterspart1
    /people/venkat.donela/blog/2005/03/03/introduction-to-simple-file-xi-filescenario-and-complete-walk-through-for-starterspart2
    /people/arpit.seth/blog/2005/06/02/file-receiver-with-content-conversion
    /people/anish.abraham2/blog/2005/06/08/content-conversion-patternrandom-content-in-input-file
    /people/shabarish.vijayakumar/blog/2005/08/17/nab-the-tab-file-adapter
    /people/venkat.donela/blog/2005/03/02/introduction-to-simplefile-xi-filescenario-and-complete-walk-through-for-starterspart1
    /people/venkat.donela/blog/2005/03/03/introduction-to-simple-file-xi-filescenario-and-complete-walk-through-for-starterspart2
    /people/venkat.donela/blog/2005/06/08/how-to-send-a-flat-file-with-various-field-lengths-and-variable-substructures-to-xi-30
    /people/anish.abraham2/blog/2005/06/08/content-conversion-patternrandom-content-in-input-file
    /people/shabarish.vijayakumar/blog/2005/08/17/nab-the-tab-file-adapter
    /people/jeyakumar.muthu2/blog/2005/11/29/file-content-conversion-for-unequal-number-of-columns
    /people/shabarish.vijayakumar/blog/2006/02/27/content-conversion-the-key-field-problem
    /people/michal.krawczyk2/blog/2004/12/15/how-to-send-a-flat-file-with-fixed-lengths-to-xi-30-using-a-central-file-adapter
    /people/arpit.seth/blog/2005/06/02/file-receiver-with-content-conversion
    http://help.sap.com/saphelp_nw04/helpdata/en/d2/bab440c97f3716e10000000a155106/content.htm
    Please see the below links for file content conversion..
    /people/michal.krawczyk2/blog/2004/12/15/how-to-send-a-flat-file-with-fixed-lengths-to-xi-30-using-a-central-file-adapter - FCC
    /people/michal.krawczyk2/blog/2004/12/15/how-to-send-a-flat-file-with-fixed-lengths-to-xi-30-using-a-central-file-adapter - FCC
    File Content Conversion for Unequal Number of Columns
    /people/jeyakumar.muthu2/blog/2005/11/29/file-content-conversion-for-unequal-number-of-columns - FCC
    Content Conversion (Pattern/Random content in input file)
    /people/anish.abraham2/blog/2005/06/08/content-conversion-patternrandom-content-in-input-file - FCC
    /people/harrison.holland5/blog/2006/12/20/xi-configuration-for-mdm-integration--sample-scenario - FCC - MDM
    XI in the role of a FTP
    /people/shabarish.vijayakumar/blog/2006/04/03/xi-in-the-role-of-a-ftp - FCC
    File to R/3 via ABAP Proxy
    /people/prateek.shah/blog/2005/06/14/file-to-r3-via-abap-proxy - FCC
    /people/mickael.huchet/blog/2006/09/18/xipi-how-to-exclude-files-in-a-sender-file-adapter - EOIO - File
    http://help.sap.com/saphelp_nw04/helpdata/en/ee/c9f0b4925af54cb17c454788d8e466/frameset.htm - cc
    http://help.sap.com/saphelp_erp2005vp/helpdata/en/95/bb623c6369f454e10000000a114084/content.htm - fcc cOUNTER
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/da1e7c16-0c01-0010-278a-eaed5eae5a5f - conversion agent
    cheers

  • File Content Conversion for complex structure

    Hi
    I have a requirement to repeat a structure consisting of three lines i.e the segment  containing these 3 lines will have occurrence 0....unbounded and will be repeated in the File multiple times ,
    What is the level that can be handled in File Content Conversion's recordset structure ?
    My issue is that  the structure is
    Dt_File -> Repeating Level1->Level2 ->Field1
                                                ->Level2a->Field3
                                                -> Level2b->Field5
    where the first level is DT_File
    under which I have RepeatingLevel1 as a SubElement
    and under Repeating level I have Level2 , Level2a and Level2b at its subelementsl
    and under Level2 I have Field1 , Under Level2a i have Field3 and under Levle 2b i have Field5
    How do i handle this in the Content Conversion ?? as in how do I create my Recordset Structure ?? as it just handles one level below the Document Name (i,e) Message Type)
    Is it possible ??? or should i consider some other way to constuct my data type ??
    Thanks
    Dev

    Hi Tarang
    My DT according to the target file structure is this :
    DT_File
    >Main1(1,1)
    >Main2(1,1)
    >Main3(0...unbounded)
    >Record1(1,1)
    >Field1
    >Field2
    >Field3
    >Record2(1,1)
    >Field4
    >Field5
    >Record3(1,1)
    >Field6
    >Field7
    SO I want to confirm if the receiver FCC will be   -     Main1,Main2,Main3,Record1,Record2,Record3
    Record1.fieldSeparator  ,
    Record1.endSeparator     'nl'
    Record2.fieldSeparator  ,
    Record2.endSeparator     'nl'
    Record3.fieldSeparator  ,
    Record3.endSeparator     'nl'
    or                                                                   Main1,Main2,Record1,Record2,Record3
    Thanks
    Dev

Maybe you are looking for

  • Can I use icloud to find my iphone3g?

    HI, We just gave our daughter our old iPhone3G running 4.2   How can we set it up so we can log into icloud on a computer, and locate it using the Find my Iphone service?   I used to be able to do this when I used it and had a Mobile me account a yea

  • Did OS 10.9.1 gum up internet speed?

    Computer at work (Verizon is ISP, DSL) and another 2 machines at home (cable isp), both Firefox and Safari are incredibly slow even though Speedcheck seems OK (6600 at work and 15,500 at home!).  Gummed up since OS 10.9.1 update after noon today.  Oh

  • Dataload error using MaxL on LINUX

    Hi All, I'm using Essbase 11.1.2.1 & working on ASO cube. I'm trying to load the data using Maxl on LINUX. This is the following error: essmsh error: End of File breaks the Statement. any ideas....... Thanks,

  • Maximum Bouncing file size?

    Im using Logic to record class lectures which end up being anywhere from 2 1/2-3 1/2 hours long at the longest. They are being bounced as MP3's yet, when i go to bounce the file it is telling me that i have exceeded the 2.0 GB maximum... The shorter

  • UWL substitution at workitem level

    Hi, I've gone through threads like [this|Substitute - Delegation in MSS;. I've also read How-To docs related to Substitution Proflle. What I understand is that the Substitution Profile approach is task specific. So if you change it at the task level