Network streams vs shared variables

I send data from a PXI RT System to users on different Windows computers via Shared Variable and Network Stream.  The user that receives the data via Network Stream writes the data to a disk file (aka DAQ computer).  The users that receive the data via Shared Variable displays it on front panels (aka Observers). 
The data consists of a 1D SGL array where elements 0-3 are the timestamp, element 4 is the counter, and elements 5-1000+ are data.  The timestamp is GPS time and is displayed on all computers.  When I look at the timestamp on the DAQ it is slowly falling behind the current GPS time.  After 4 hours it can be up to a minute behind.  When I look at the timestamp on the Observers it is always displaying current GPS time.  When I look at the code on the PXI System, it is always sending the current GPS time.  The counter on the DAQ computer is also behind.
I am using the Read/Write Single Element Stream functions with the default read/write buffer size of 4096.  The 'timed out?' output is always FALSE for both functions.  No errors are generated.  LabVIEW memory usage is constant during the whole time.
On the PXI RT System the Network Stream and Shared Variable are being written to inside a Timed While Loop.  The users read the data within a standard While Loop.  Everyone is using LabVIEW 2011.
It sounds like a buffer is slowly being filled up somewhere, but where?
Solved!
Go to Solution.

On the PXI RT System:
How often is data sent?
Are you using a “Flush Stream” function after your “Write Single Element to Stream”?
On the “DAQ Computer”:
Are you buffering the reading of the data (i.e. feeding it to a queue)?
You might try using a property node to read “Available Elements for Reading” to see if they are stacking up here.
The buffer size is another option to consider.
steve
Help the forum when you get help. Click the "Solution?" icon on the reply that answers your
question. Give "Kudos" to replies that help.

Similar Messages

  • Serializin​g read/write operations of network-pu​blished shared variables

    Hi all,
    I'm developing a distributed application (PC + CompactRIO), and using shared variables (SVs) for inter-device communication. Here's my journey so far:
    Intended procedure
    PC parses file
    PC writes processed file data (custom cluster, large) into the 1st SV 
    PC writes a "grab data" signal/command (enum) into the 2nd SV
    cRIO polls the 2nd SV
    cRIO sees the command, then reacts by reading the 1st SV
    Steps #2 and #3 were sequenced, using error wires.
    Unexpected results
    Even after the command is transmitted and the cRIO sees it, the cRIO could not read the data (which I wrote BEFORE the command) -- LabVIEW reported that the buffer was empty.
    The operation succeeded when I placed a wait (5 seconds) between steps #2 and #3.
    Questions
    What am I doing wrong, and how do I achieve my desired outcome?
    Is SV I/O asynchronous by design?
    Is it possible to use event-driven programming to handle SV access? (i.e. does LabVIEW signal when the new SV value has propagated across the network?)

    BillMe wrote:
    Why do you have to "notify" the other end that data is available? The subscriber can simply sit in a loop doing a timed read just as if using a queue or notifier IPC. If it doesn't time out, you got new data. If it does time out, do some other processing if needed and then loop back for another timed read.
    My sytem architecture is command-driven -- the cRIO listens for instructions from the PC interface (sent as an enum via one SV), and performs tasks (motor control) in response. One of the commands (the one described in this thread) happens to be "download a new motion profile from the PC, by reading the other SV". Given that the cRIO is already polling the command channel, I felt that there's no need to also poll the data channel (especially since the "download" command is issued very infrequenty). Plus, I thought that polling two channels would increase the chances of race conditions or illegal state transitions, particularly if the app is developed over a long term.
    I am also new to LabVIEW, so my current programming style will heavily reflect my C++/Qt background while I get a feel for LabVIEW's strengths and weaknesses -- Qt is a heavily event-driven framework (even for networking!), where polling often means you're doing something wrong.
    Still, thank you for pointing out that I can use timeouts to determine if new data has arrived -- my subscriber current writes a null command back into the SV when it has consumed the command, but you showed me that I don't have to.

  • How do you synchroniz​e accesses to a LabVIEW Shared Variable?

    I would like to create an ad-hoc weather station program (I'll explain more in a bit).  I am using LabVIEW 8.0 Full Edition, and I would like to share data over a network between stations with the LabVIEW Shared Variable.  Here's what I want to be able to do:
    A node would start up, and begin publishing data to a network via a shared variable.
    The shared variable is an array of clusters
    The cluster information would hold things like:
    Station Name
    Station Location
    Weather information cluster (temperature, rainfall, windspeed, wind direction, etc...)
    Timestamp of last update
    When a new node would like to enter, it would bind to the shared variable, grow the array, and add its information.
    If a node's Station Name and Station Location is already in the shared variable, it would merely update the information in the cluster.
    Viewing nodes could pop in, bind to the shared variable, and read/display the information at any time. 
    I am trying to enumerate problems with this before implementing, and I have run into a stinker of a problem that I am not sure how to solve.  How do I synchronize accesses to the LabVIEW Shared Variable?  If I read the variable, modify it, and write it back, I will undoubtedly run into a race condition where 2 nodes attempt to update its data and I will lose the data written by the first node - Node A reads, Node A modifies, Node B reads, Node A writes, Node B Modifies, Node B Writes, and thus the modifications made by Node A are lost.  In my specific application losing some data isn't critical, but if not remedied this type of problem could cause massive amounts of data to be lost when there are numerous nodes, and that is definitely not acceptable. 
    Does anyone have any recommendations on how to synchronize the read-modify-write operations on the data in the Shared Variable?
    -Danny

    Wendy,
    I am afraid Semaphores are not network-shared objects (to my knowledge), they are system-level objects that use operating-system synchronization mechanisms.  If I were synchronizing on a single machine, a semaphore might be a valid mechanism; as an aside, most user-mode semaphores are designed to synchronize within a single process - to synchronize between processes you need to store the semaphore in the Kernel, and to synchronize over a network you would need a network node to handle serialization of requests.  My Shared Variable is published over a network, and to my knowledge there are no network-published synchronization mechanisms available - mostly because there is no way to currently perform an atomic test-and-set on the Shared Variable (am I correct?) and there isn't a mechanism for blocking access to a Shared Variable from another network device/machine (or is there?).  I've been looking for some way to implement an atomic test-and-set but I am running into a wall; I know that if I select the "single writer" attribute of the Shared Variable I can get LabVIEW to force a single writer allowing me to have an atomic "set", but I need more than that.
    If only there was a network-shared Semaphore or some way to block other network accesses to the Shared Variable I would be in business - something like what I want doesn't exist, does it?
    Thanks!
    -Danny
    Message Edited by texasdiaz on 02-23-2006 02:52 AM

  • Shared Variables for Real-TIme Robot Control

    I'm really stuck in my efforts to use LV real-time in my hardware control application. I have a 6-axis industrial robot arm that I must control programmatically from my PC. To do this I've developed a dynamic link library of functions for various robot control commands that I can call using Code Interface Nodes in LV (using 8.5). This has worked great, that is, until I tried to port parts of the application to a real-time controller. As it turns out, because the robot control dll is linked with and relies so heavily upon several Windows libraries, it is not compatible with use on a RT target, as verified by the the "DLL Checker" application I downloaded from the NI site. When the robot is not actually executing movements, I am constantly reading/writing analog and digital I/O from various sensors, etc.....
    This seemed to suggest that I should simply segregate my robot commands from the I/O activities, using my host PC for the former, and my deterministic RT loop on the target machine for the latter. I set up a Robot Controller Server (RCS) vi running on my host PC that is continuously looking for (in a timed loop) a flag (a boolean) to initiate a robot movement command. Because several parameters are used to specify the robot movement, I created a custom control cluster (which includes the boolean variable) that I then used to make a Network Shared Variable that can be updated by either the RT target or the host PC running the RCS. I chose NOT to use buffering, and FIFO is not available with shared variables based on custom controls.
    Here's sequence of events I'd like to accomplish:
    1) on my host PC I deploy the RCS, which continuously pools a boolean variable in the control cluster that would indicate the robot should move. The shared variable cluster is initialized in the RBS and the timed loop begins.
    2) I deploy the RT vi, which should set the boolean flag in the control cluster, then update the shared variable cluster.
    3) an instance of the control cluster node in the RCS should update, thereby initiating a sequence of events in a case structure. (this happens on some occassions, but very few)
    4) robot movement commands are executed, after which the boolean in the control cluster is set back to its original value.
    5) the RT vi (which is polling in a loop) should see this latest change in the boolean as a loop stop condition and continue with the RT vi execution.
    With the robot controller running in a timed loop, it occassionally "sees" and responds to a change of value in members of the shared variable cluster, but most times it does not. Furthermore, when the robot controller vi tries to trigger that the movement has completed by changing a boolean in the control cluster, the RT vi never sees it and does not respond.
    1) Bad or inappropriate use of network shared variables?
    2) a racing issue?
    3) slow network?
    4) should I buffer the control cluster?
    5) a limitation of a custom control?
    6) too many readers/writers?
    7) should I change some control cluster nodes to relative, rather than absolute?
    8) why can't I "compile" my RT vi into an executable?
    Any help would be greatly appreciated. Unfortunately, I'm writing this from home and cannot attach vi files or pictures, but would be happy to do so at work tomorrow. I'm counting on the collective genius in the universe of LV users and veterans to save my bacon.....
    David

    Hi David,
    I'm curious why you decided to build a CIN instead of developing the code in
    LabVIEW.  Is there some functionality that that LabVIEW couldn't
    provide?  Can you provide some more information about the LabVIEW
    Real-Time target you're using?  What type of IO are you using?
    It is impossible to get LabVIEW Real-Time performance on a desktop PC running
    an OS other than LabVIEW Real-Time.  Even running a timed loop in LabVIEW
    for Windows won't guarantee a jitter free application.  Also, no TCP based
    network communication can be deterministic.  This means Network Shared
    Variables are also not deterministic (they use a TCP for data transport) and I
    advise against using them as a means to send time critical control data between
    a Windows host and a LabVIEW Real-Time application.
    In general, I would architect most LabVIEW-based control applications as
    follows:
    - Write all control logic and IO operations in LabVIEW Real-Time.  The
    LabVIEW Real-Time application would accept set points and/or commands from the
    'host' (desktop PC).  The Real-Time controller should be capable of
    running independently or automatically shutting down safely if communication to
    the PC is lost.
    - Write a front-end user interface in LabVIEW that runs on the desktop
    PC.  Use Shared Variables with the RT-FIFO option enabled to send new set
    points and/or commands to the LabVIEW Real-Time target.
    Shared variable buffering and RT-FIFOs can be a little confusing.  Granted
    not all control applications are the same, but I generally recommend against
    using buffering in control applications and in LabVIEW Real-Time applications
    recommend using the RT-FIFO option.  Here's why:  Imagine you have a
    Real-Time application with two timed loops.  Time-loop 'A' calculates the
    time critical control parameters that get written to hardware output in
    timed-loop 'B'.  Loop 'A' writes the outputs to a RT-FIFO enabled variable
    with a RT-FIFO length of 50.  Loop 'B' reads the outputs from the shared
    variable, but for some reason, if loop 'B' gets behind then the shared variable
    RT-FIFO will now contain several extra elements.  Unless loop 'b' runs
    extra fast to empty the RT-FIFO, loop 'B' will now start outputting values that
    it should have output on previous cycles.  The actual desired behavior is
    that loop 'B' should output the most recent control settings, which means you
    should turn off buffering and set the RT-FIFO length to 1.
    There is also a clear distinction between buffering and the RT-FIFO
    option.  The RT-FIFO option is used to add a non-blocking layer between
    network communication and time-critical code in LabVIEW Real-Time
    applications.  It also provides a safe mechanism to share data between two
    loops running in a Real-Time application without introducing unnecessary
    jitter.  Network buffering is a feature that allows a client to receive
    data change updates from the server even if the client is reading the variable
    slower than the server is writing to it.  In the example I presented above
    you don't need to enable networking because the shared variable is used
    entirely within the Real-Time application.  However, it would be
    appropriate to send control set points from a Windows PC to the Real-Time
    application using network published shared variables with the RT-FIFO option
    enabled.  If it is critical that the Real-Time application executed all
    commands in the sequence they were sent then you could enable an appropriate
    buffer.  If the control application only needs the latest set point
    setting from the Windows host then you can safely disable network buffering
    (but you should still enable the RT-FIFO option with a length of 1 element.)
    Network buffering is especially good if the writer is 'bursty' and the reading
    rate is relatively constant. In the robot application I can imagine buffering
    would be useful if you wanted to send a sequence of timed movements to the
    Real-Time controller using a cluster of timestamp and set point.  In this
    case, you may write the sequence values to the variable very quickly, but the
    Real-Time controller would read the set points out as it proceeded through the movements.
    The following document presents a good overview of shared variable
    options:  http://zone.ni.com/devzone/cda/tut/p/id/4679
    -Nick
    LabVIEW R&D
    ~~

  • Problems with communication across a network using shared variables

    I have two programs(projects) running on two different computers connected with a LAN. I am using LabVIEW 8.0, and the DSC-module. The program on one of the computers have measurements that I want to collect and show on the program running on the other computer on the network. I choose the indicator where I want to show the data, select ''Properties'', ''Data binding'', ''Shared Variable Engine (NI-PSP)'', ''Network Items'' and then browse for a Network...but the problem is that in my ''Network Neighborhood'' There is only one computer...and that is the one I am one...not the computer on my Network that I want to communicate with....
    Have anyone any suggestions on how to solve this?
    Kind regards Mari

    Mari,
    Check this link regarding trouble shooting network-published shared variables:
    http://digital.ni.com/public.nsf/websearch/6E37AC5435E44F9F862570D2005FEF25?OpenDocument
    This might be a firewall issue, so I would check that first.
    Frode

  • Distributed application: Networked Shared Variables, Named Services (Raw TCP/IP) or Other?

    Happy New Year NI forums! 
    I am working on a project involving mobile interacting robots. In the future it is likely the application's components may need to run on different PCs (Targets). Note: at this point in time all the components are seperate but all running on the localhost machine. Thinking towards the future I want to pick the 'best' architecture to allow all these components (VIs performing various functions) in multiple locations. For example, several VIs on the Robots, VIs on serveral PCs. 
    I am  currently aware of using Server/Client TCP/IP using named services. My mock up works well, but is it time efficient (my time coding) I wonder.. ?  
    Whereas I am aware of networked shared variables which handle connections and all the parsing for the underlying tcp/ip communication. But will this be difficult the manage? I am unsure if I can associate shared variables with a VI similar to named services. I suppose I could pro grammatically create the variable upon initialization of the server component - and the client could just search the list of avaiaible variables to connect too. Downside this would require DSC module. 
    As you can see, I am rather unsure. Any advice would be great!
    Kind Regards,
    James  
    Kind Regards
    James Hillman
    Applications Engineer 2008 to 2009 National Instruments UK & Ireland
    Loughborough University UK - 2006 to 2011
    Remember Kudos those who help!

    Hi Jason,
    Thanks for your reply. I hope your enjoying NI UK as much as I did.. fun times!
    I have seen the link you posted a few times before. But today, I took a better look at it.
    My issue is I need several multi-client severs, i.e. many servers which allow multiple clients to connect to them.
    Now the STM does have an example of this - STM mutli-client Example - Server.vi (used with the STM mutli-client.vi)
    However, when a make copies of these code (to have my second server) - it refuses to run. As in , it just stops itself.
    I DID change the port number, on the lister aspect of the server code. But I Am unsure what else I would need to change to get this setup to work?
    One thought I had was, the FIFOs all having the same name - this probably isn't a good idea between servers.
    Any suggestions would be grateful!
    *please could you provide me email support
    Kind Regards,
    James Hillman  
    Kind Regards
    James Hillman
    Applications Engineer 2008 to 2009 National Instruments UK & Ireland
    Loughborough University UK - 2006 to 2011
    Remember Kudos those who help!

  • Network shared variables lose binding

    Hello,
    I am developing an application in LabVIEW that uses network shared variables to transmit data between two PC's on the same subnet. The shared variables work fine when running the VI's in development mode, however, when i build the vi's into an executable I find that they no longer work. Here is what I have found so far:
    I deploy the shared variable library on the publisher machine (also happens to be the development machine) through an invoke node in the executable. NI distributed system manager confirms that this does deploy and indeed updates as it should.
    For the executable on the subscriber PC I created a second shared variable library (same project) with the same shared variables and bound them to the respective shared variables from the first library by selecting enable aliasing, then bind to PSP URL and browsing to the shared variable I wish to bind it to (e.g. \\hallnet-ellm2\shared variable library\serial Number). The machines listed under browse were listed by name so when I tried this initially and it did not work I manually changed the name of my machine in the URL box to the IP address of the publisher hoping that would fix it in case the subscriber could not resolve the publishers machine alias. So now my bind URL read \\192.168.0.1\shared variable library\serial Number.
    As part of the executable on the subscriber I deploy this second shared variable library. NI distributed system manager confirms that this deploys but under quality for an individual variable it has a list of issues (see attached) and the bound variable is not updating. At this point the publisher shared variables are still functioning fine. By clicking on 'edit variable' I can see that the variable on the subscriber is still bound but the PSP URL is now \\localhost\shared variable library\serial number. Changing the PSP URL on the subscriber to \\192.168.0.1\shared variable library\serial number enables the variable to update as expected.However by this time my executable has already picked up the error and does not function.
    I think that the issue lies with the bind URL used on the subscriber as for some reason it does not keep the binding configured in the project and instead changes to 'localhost'. Why is this? Should it not stay bound to the address specified in the project?
    I have tried changing the IP addresses in the aliases file so that
    [My Computer]
    My Computer=localhost 
    becomes
    [My Computer]
    My Computer=ip of local machine
    This did not help.
    The shared variable libraries are included in the build spec to go into the support files directory and they are successfully deployed from there on both publisher and subscriber.
    I am using LabVIEW 8.6 on Windows XP
    Thanks for any help you may be able to offer,
    Lee
    Attachments:
    distributed system manager.JPG ‏74 KB

    Hi Lee,
    I hope you are well.  Thank you for your post.  Your application sounds very interesting.
    Looking at your issue I was wondering, have you tried lowering your firewalls, as this may be causing the problem.
    Also, another option would be to setup a private network.  Do you have access to any routers that you could use to link the two machines independent of your IT's infrastructure?
    The other thing to try is two other computers entirely.  Again, it would be ideal to take them off the network you are on, but it's something to try if my prior suggestion doesn't work.  It should work on the original two machines though, and it's likely that different computers won't solve your problems because I suspect the network.
    Remember that the client variables must know the location of the variables on the server, so you can't move the server exe around without changing this value.
    Make sure to set the network location in the "Bind to Source" option for the client variables.
    It is also possible to write a separate piece of code to install on every machine that is responsible for deploying the library and by doing so eliminate the need for programmatically deploying the variables in the original application.  However, this won't really help you, because the variables you use in the application have to be the same as the ones deployed in the library, so if you change the library, they'll no longer be linked and they won't receive data.  You'd have to create a separate exe for every binding source you wanted to link to, and then have a second, known library for the sake of communication locally on the computer between the ‘deployer’ and the actual application.  The main application could then be assigned the responsibility of launching the correct ‘deployer’' if it sees it needs to switch to a different variable binding source.  This method is not the most streamlined or effective, but it might work.
    Just to let you know, you will need to use the DSC toolkit.
    Please find below some knowledge base links that I think you will find helpful in your application.
    Using Shared Variables in Executables
    How do I Programmatically Change the Data Binding Source for Shared Variables?
    I hope this information helps and if you can give these suggestions a go and let me know how you get on, that would be great.
    Kind regards,
    Prashant M
    Applications Engineer
    NI UK & Ireland

  • Modbus ip shared variable network failure

    I am using lab view 8.6 DSC module to communicate to a watlow system which contains five watlow 96 controllers and an EM gateway.  I have created shared variables for the process temperatures and setpoints for each of the five controllers using watlow modbus register Numbers with a 400001 offset.  I have also created shared variables for Updating,CommFail,UpdateNow,and UpdateRate which where predefined. I have error when starting the VI if the SV  has been  dragged and dropped into the block diagram. The message is  Error -1967353902 (The Modbus I/O server failed to receive any response from the Modbus slave device.) occurred at SV in vi. If I bind a variable in the VI to this same SV the error does not occur but the variable cycles between Good, Network Failure, No known value, and device failure as stated in the variable manager watched variables.  The Updating, CommFail and UpdateRate all have a consistent Good in the quality column of the variable manager.  UpdateNow has X in value, type, timestamp, and quality columns.  CommFail and Updating does cycle between true and false randomly.  I have tried a third party software called SpecView 32 demo to see if the commincation with the modbus system is not working and I can create five watlow controlers on my screen and direct them to the ip address along with a unit address and the system works without faults.  This leads me to believe the commincation bewteen the SV Engine and the IP address is not correct.  HELP Please. 
    Robert Jensen
    UND EERC

    If your application can deal with it I would recommend staying clear of the 'Networked Published' option.
    When I started my Modbus development on cRIO....I left it enabled, and with ~100 shared variables on a 9074, the CPU was railing, and I saw a buffering behavior on the shared variables (which was not desirable in my application).
    In my application I am using the old modbus library (as apposed to the new API) for cRIO to slave comms, the cRIO being the master.
    I am also using the IOserver making the cRIO a slave to an external SCADA - and it passes essentially the same data arrays as I use on the modbus library for my local HMI [Not an NI product].....Which is two full Modbus frame writes (@ 120 words each, and about 60 words more for ~300 words outbound from the cRIO).
    The IOserver slave was a recent addition and did not add much to the CPU load - although only 16 bytes is high speed, the balance of the total word package is at either 1 second or 3 seconds.
    So, in my experince, the 'Networked Published' option adds significant CPU loading (on entery level cRIOs) YMMV.
    I am huge fan of the shared variable engine (some at NI were pusing the CVT, and TCE etc...). However most of my shared variables are not the Networked Published variety (excepting local module channels) those have remained networked published for DSM (Distributed System Manager) use.

  • Not able to access Network Shared Variable when deployed in PC

    Initially, when we deploy a Network Published Shared Variable in PC and try to access the same (Read/Write) from RT, we get an error/warning "-1950679023". But when we access the same variable from the PC, it works fine. In the distributed system manager, we can see the variable getting deployed. Also the value changes in Distributed System Manager if we write a value from PC. The attached image "Shared variable Issue.png" will give more understanding of this issue. 
    The other way round it works fine i.e deploying in RT side and accessing from both RT and PC is working fine. 
    We also see that the network adapter settings is not loading properly in MAX, if at all we install any software in RT. With no software installed, it loads properly. 
    The following were the steps that we tried to solve the issue. 
    1.Flushing the entire NI software and Re- installing again 
    2.Formatting the RT(PXI). 
    3.Removing the EtherCAT Card and testing. 
    4.Checked the network properties of the RT network. 
    5.Checked the IP/Subnet/Gateway settings. 
    6.Checked Firewall Settings, If Shared Variable Engine is accessible.
    Attachments:
    Shared variable Issue.png ‏491 KB

    First Root cause needs to be identified before any actions.
    I would suggest first check if you can access the shared variable hosted in PC from RT using other ways like using SVE API (Logos and PS protocols, Datasocket etc..)
    Check if antivirus or firewall is playing...
    Check the same experiment with some other PC if you can.
    You can also try creating another Shared Variable in RT and binding the same to the PC and try to access it...
    Since you have did all the reinstallations already
    Best Regards,
    Vijay.

  • Using network shared variables in two computers connected via a network switch

    let me start by saying im a rookie to the programming environment but i have used Labview a couple of times to understand the basics,  i have a computer and a laptop (both using vista), both of them with Labview Full development System (Student ed. with Mathscript) installed, so what im tryin to do is to use the built in microphone located in the laptop to aquire sound and then use a Shared Variable to transfere the sound signal from the laptop to the computer, the laptop and the computer are connected to a network via a network switch and ethernet cables,  so far i nothing worked, i can manage to create the shared variable in the laptop and use it there but it doesnt appear in the computer, im not sure whats the problem i have even disabled firewalls in both systems, help from anyone wil be appreciated.....

    Hi Lukie,
    This KB should be of some assistance to you.
    Trouble shooting network published shared variables
    Also the following link gives some instructions on the use of shared variables.
    http://zone.ni.com/reference/en-XX/help/371361B-01/lvhowto/bind_to_source/
    I hope this is of some assistance, let me know if you have any more problems.
    All the best,
    Message Edited by mickeyw on 08-05-2008 12:29 PM
    Mike W
    Applications Engineer
    National Instruments UK&Ireland

  • RT Network Shared Variable and Visa Serial Instr class

    Hi,
    I'm using Labview 2009 SP1 with the RT module. I've had no problems creating a RT Target application and a Host PC application which are interconnected using Network Shared Variables, until I came to the COM ports fitted to the RT Target (PXI Embedded Controller and 2 x 4 port COM cards).
    I can configure and use the COM ports in the RT Target application providing I use constants to define which COM port to use, i.e. VISA OPEN function accepts hardcoded "COM2" , (VISA Serial Instr class).
    But I want to pass the COM Port resource name from my host application. 
    Is there a suitable Network Shared Variable I can create ? or how do I change the string value (COM Port name) of the VISA Serial Instr class variable in the RT Target application ?
    thanks,
    Gary.

    Hi there Gary,
    Thanks fot the post. I think I have found something that may be if use to yourself.
    http://labviewwiki.org/Functional_global_variable
    This is the functional global variable.
    Take a look at it and let me know what you think!
    Many thanks,
    Liam A.
    National Instruments
    Applications Engineer

  • Shared variable engine network published source issue

    Hello,
    I am attempting to use the shared variable engine to share some simple stings over a network between a Windows 7 computer and a Windows XP computer. 
    I got through the shared variable example just fine and can share variables between VIs on a single computer. When I open the shared variable engine, it shows the client and server variables that are shared on the local computer. I then create a new process, and attempt to define a new variable, and the Shared Variable Property screen comes up. I attempt to "Bind to Source" and click browse, and see the computer name I am attempting to connect to. However, when I click it, it stalls and I cannot expand the computer to find the variable I am trying to bind to. What am I missing?
    Thanks, Arron

    Arron,
    This document may be useful in helping to setup your network shared variables. Take a look at this and see if you have followed all the outlined steps in setting up a network shared variable.
    http://zone.ni.com/devzone/cda/tut/p/id/4679
    Let me know how this works for you.
    -Nick-
    Nick C | Staff LabVIEW Platform Product Support Engineer | National Instruments

  • Binding shared variable in executable across network

    I can't seem to get a shared variable to bind from an executable on another computer back to a source variable on the main machine.
    I can get the remote variable to change with programmatic access.  Is it possible to have shared variables in an executable bind to a PSP URL on another computer?  This is labview 2011.
    I can see everything with NI Distributed System Manager, and the programmatic access changes the remote variable, so it's not a network issue.
    Thanks for any insights.  This just doesn't seem to work the way NI's online white papers say it shoud.

    What I don't understand is why after binding to a specific URL, the "Shared Variable Deployment" screen of the application builder makes the target "my computer". 
    I probably could get this to work if I changed the network address of "my computer" in the ini file created in Application Builder?
    This seem a strange way for this binding process to work.  If the absolute target (for shared variable bound to another variable and referencing "absolute") was retained when the VI goes through the application builder, it would make for sense.
    I can't get this to work any way with using bound variables.  The only way this works is using programmatic access to shared variables in the built app, and I don't consider this the same thing.
    My conclusion is that shared variable binding and appropriate absolute references to deployed variable libraries do not survive passing through the application builder with their absolute references intact.

  • Shared Variable communication (network publiched )

    Hi all ,
    The whole day I have been banging my head with Shared variable communication between RT Host and host computer :
    I essentially attempted to pass an array from the RT host to the Host computer .For this purpose I used a Network published shared variable of type Array U64 . I utilized this link to help me understand usign shared variable communication 
    http://www.ni.com/white-paper/4679/en .. 
    I also enabled RT FIFO .Now in the mentioned link this the information given about using single element FIFO or Multi element FIFO
    '' By enabling the real-time FIFO, you can select between two slightly different types of FIFO-enabled variables: the single-element and the multielement buffer. One distinction between these two types of buffers is that the single-element FIFO does not report warnings on overflow or underflow conditions. A second distinction is the value that LabVIEW returns when multiple readers read an empty buffer. Multiple readers of the single-element FIFO receive the same value, and the single-element FIFO returns the same value until a writer writes to that variable again. Multiple readers of an empty multielement FIFO each get the last value that they read from the buffer or the default value for the data type of the variable if they have not read from the variable before.'' 
    I had read the above content a 100 times but still I am not able to get a clear picture of the difference and when to use which option .So I decided to throw away the text and attempted to try somethign out for myself .
    I had a loop in the RT host that writes different 3 element arrays into the ''network published shared variable '' . Now when I use the multi element option with '' number of arrays as - 2 '' I am able to read the arrays seperates one by one in the host computer ( as we can read a general queue).
    Now when I used the single element option for the RT FIFO with un editable 1 array option ,only the last written array into the ''network published shared variable '' gets read in the host computer .
    This sounds absolutely silly as if this is the case then what is the purpose of setting the ''buffer''.For testing purposes I had set the buffer as 5 arrays .
    In fact I have only one writer ( writing in loop in the RT Host ) and one reader ( again reading in loop in the Host computer ).So I am not even sure if I require The RT FIFO option for the network published shared variable .
    I apologise for the long message but I have reached the limits of running in circles waiting to bang somewhere
    I know I am doing a silly mistake somewher or I am probably missing a simple obvious trick but dont know what it is ..
    I request for some clarity .. In fact I had posted a little while earlier today as well .... link - http://forums.ni.com/t5/LabVIEW/RT-Host-to-Host-computer-communication/td-p/2348130 )
    any help would be appreciated
    Cheers
    me  
    Solved!
    Go to Solution.

    Hi,
    I think the difference between both types is clearer in the LabVIEW help :
    Enabling the Real-Time FIFO
    You can enable the real-time FIFO of a shared variable from the Real-Time FIFO page of the Shared Variable Properties dialog box. Place a checkmark in the Enable Real-Time FIFO checkbox to deterministically share data using single element or multi-element FIFOs.
    Single Element FIFO
    A single-element FIFO shares the most recent data value. The shared variable overwrites the data value when it receives a new data value. Use this option when you need only the most recent value. Configure the size of the array elements or the size of the waveform for the FIFO buffer if you select an array or waveform data type.
    Multi-Element FIFO
    A multi-element FIFO buffers the values shared by the shared variable. You can configure the size and the elements of the FIFO buffer to match the settings from the Use Buffering section of the Variable page, or you can configure a custom size for the FIFO and the FIFO elements.
    Note  For both single-element and multi-element FIFOs, if the variable contains array or waveform data, you must configure the size of the FIFO elements equal to the size of the data you want to share. If both the network buffer and the RT FIFO are enabled, the network buffer must be at least as large as one FIFO element. Sharing data smaller or larger than the length you specify causes a memory allocation that affects determinism.
    Note  Waveforms contain variable-size variant elements that are not compatible with the Real-Time FIFO. Therefore, if you enable the Real-Time FIFO on a shared variable that contains waveform data, the variant element of the waveform data does not transfer.
    http://zone.ni.com/reference/en-XX/help/370622K-01/lvrtconcepts/rt_projectvariable/#Single_Element_F...
    'Hope it helps
    Aurelie

  • Network Shared Variable: Aliasing not working

    Hello!
    I am running a cRIO 9075, which is publishing network shared variables.
    I can see and modify them within Distributed System Manager.
    Unfortunately I am not able to read/write the variables through labview.
    What I have done so far:
    Tools -> Shared Variable -> Register Computer, using the IP of the cRIO
    Adding a Variable to the project. Type = Network-Published, Enable Aliasing, choosing "Browse" to select the variable (all published variables from cRIO are shown there), Access Type = read/write. The PSP-URL is: \\192.168.10.70\WaveformManager\Op
    Trying to read the variable results code -1950679034 and the result is always the default value for that data type.
    BUT this works: using the VIs Data Communication / Shared Variable / Read/Write Variable  and typing in the same URL the Distributed System Manager is showing is showing (in my case: \\192.168.10.70\WaveformManager\Op)
    So, what am I doing wrong? Did I forget something or misunderstand how "Aliasing" works?
    Thanks!

    hi,
    in which way to you read your shared variable? If you read it before you write  a value "into" the variable it may couse this waring.
    Have you tried this?
    http://digital.ni.com/public.nsf/allkb/7DBC2C3E95AFD85C86257442005CF74C?OpenDocument

Maybe you are looking for

  • Progress tracking Procedure In PS

    Hi It's a investment Project Scenario. Can anybody please tell me the required configuration for progress tracking? Say For example, By means of an activity I've created one PR. And i want to see the status of that activity in terms of the progress o

  • Cannot Update  Nano

    Hi, hope someone can help me. When I try to update my NANO,I get a message saying SONGS ON THE IPOD CANNOT BE UPDATED BECAUSE ALL OF THE PLAYLISTS SELECTED FOR UPDATING NO LONGER EXISTS. If I then click OK I get a message saying The IPOD cannot be up

  • Transfer PO Conditions to R/3 in Extended Scenario (SRM 5.0)

    Hi all, We are using SRM 5.0 Extended Scenario. For controlling reasons we would like to transfer the whole conditions scheme (PO) from SRM to R/3 as well, so you could see the price calculation with rebates etc. in the R/3 position as well. I have d

  • How to compile a Java file

    Hi All, I am extending a seeded CO and when I try to compile it in JDev , it asks for many class files the seeded CO imports. I have copied all those imported files to my local system and when I try to compile , it still throws an error that some cla

  • How to update trial version to full using activation code just downloaded