Problems with communication across a network using shared variables

I have two programs(projects) running on two different computers connected with a LAN. I am using LabVIEW 8.0, and the DSC-module. The program on one of the computers have measurements that I want to collect and show on the program running on the other computer on the network. I choose the indicator where I want to show the data, select ''Properties'', ''Data binding'', ''Shared Variable Engine (NI-PSP)'', ''Network Items'' and then browse for a Network...but the problem is that in my ''Network Neighborhood'' There is only one computer...and that is the one I am one...not the computer on my Network that I want to communicate with....
Have anyone any suggestions on how to solve this?
Kind regards Mari

Mari,
Check this link regarding trouble shooting network-published shared variables:
http://digital.ni.com/public.nsf/websearch/6E37AC5435E44F9F862570D2005FEF25?OpenDocument
This might be a firewall issue, so I would check that first.
Frode

Similar Messages

  • Use shared variables with FPGA device on Host PC

    Hi all I am having a frustrating problem. I am trying to use shared
    variables linked to a cRIO 9012. The shared variables were created and
    then written to in a RT vi. is there any way I can assign locations to
    these not within a RT vi. I altimately need to run the Host vi on a
    TPC-2512 touch panel computer and I can't run a RT application on that. I
    just need the variables to update without the RT vi running and I can't
    figure out how to do that, if its even possible. Here is what I have so
    far. Thank you in advance for your help.
    Attachments:
    PumpMonitoringDevice.zip ‏2083 KB

    Adam:
    You may be able to use arrays to speed up your program, but bear in mind that the TPC is pretty much guaranteed to be slower than your computer (as it's likely to have lower system specs).
    You'll want to use the array manipulation functions to combine and retrieve your data (most useful will likely be "Build Array" and "Index Array," see context/LabVIEW help for more details). Once you have the data in an array, you can likely pass it through a shared variable configured for an array datatype.
    I'm not sure if/how much of a speed boost it will give you, but I think it's definitely worth trying. If you're not sure about the speed, try simply cutting your variable count in half and see what kind of speed increase you get with the same amount of code but fewer variable values being transmitted through your network connection.
    Good luck!
    Caleb Harris
    National Instruments | Mechanical Engineer | http://www.ni.com/support

  • Complex Problem with Time Capsule and Network

    I have setup an airport network based on a 500 gb Time Capsule which for about a year was working perfectly. Last days some problems came up. The network is shared to 2 different macbooks pro. The first macbook pro works perfectly, the internet connection is stable and fast. The other macbook works weird: Although it finds the network the internet speed is very slow and not stable. Also it can't backup on the time capsule as it used to do (msg: can't find the server). Ι have the same network settings for both the macbooks pro and I had several times restart and reset the time capsule.
    Thanks in Advance
    Costas

    I suspect that you are using someone else's airport connection. That would let you access the internet, but not access your file server. go to the airport menu and make sure that you are using your airport connection.
    If that does not work, does everything work well when the computer is within a few feet of the time capsule?

  • Problem With PXE Across Subnets

    I'm having a problem with PXE across subnets. The workstation boots,
    finds the dhcp server, finds the tftp server, downloads linux.1 and
    linux.2 with no problem. It is unable to download linux3.tgz, however.
    I've tried two different zen servers. I can tftp the file from either
    zen server in windows with no problem. I can tftp it from maintenance
    mode if I use a workstation as a tftp server. I can tftp it in PXE on
    the same subnet with no problems.
    A packet trace on the workstation shows that it gets so far into the
    download and then begins getting ICMP 'destination unreacable' packets
    from the server with the 'port unreachable' flag set.
    It sounds as if the server is closing the conversation on that port.
    Can anyone shed any light on this for me?
    Dave Thomas
    Rivercrest Technologies, Inc.

    Could you send me that trace? I would like to have a quick look
    Ron
    [email protected]
    <[email protected]> wrote in message
    news:iNOie.234$[email protected]..
    > The source address is the zen server. I'm relatively certain there is
    > not routing issue because I can tftp the file from windows with no issues
    > etc. Also there are a lot of other services crossing the subnets that
    > would fail if there is a routing issue.
    >
    > The 'port unreachable' flag seems to indicate that the zen server has
    > stopped listening on the port that is being used for the transfer.
    >
    > Dave Thomas
    >
    > > Where do these ICMP "destination unreacable" come from? could there be a
    > > routing issue to get to the imaging server?
    > >
    > > Ron
    > >
    > > <[email protected]> wrote in message
    > > news:[email protected] oups.com...
    > > > I'm having a problem with PXE across subnets. The workstation boots,
    > > > finds the dhcp server, finds the tftp server, downloads linux.1 and
    > > > linux.2 with no problem. It is unable to download linux3.tgz,
    > however.
    > > >
    > > >
    > > > I've tried two different zen servers. I can tftp the file from either
    > > > zen server in windows with no problem. I can tftp it from maintenance
    > > > mode if I use a workstation as a tftp server. I can tftp it in PXE on
    > > > the same subnet with no problems.
    > > >
    > > > A packet trace on the workstation shows that it gets so far into the
    > > > download and then begins getting ICMP 'destination unreacable' packets
    > > > from the server with the 'port unreachable' flag set.
    > > >
    > > > It sounds as if the server is closing the conversation on that port.
    > > >
    > > > Can anyone shed any light on this for me?
    > > >
    > > > Dave Thomas
    > > > Rivercrest Technologies, Inc.
    > > >
    > >
    > >
    >

  • How to use shared variables with native c programs

    Hello
    What is the way to use shared variables with native c programs?
    I have a c/c++ program that uses the NIDAQmx C-API to perform measurements. Now I want to communicate to a LabVIEW program via shared variables.
    Is there a C-API for shared variables as there is for the NIDAQmx functionality? Where can I find further documentation? The document "Using the LabVIEW Shared Variable" mentions that one "can read and write to shared variables in ANSI C", but there are no hints about how and where to look.
    Thanks in Advance

    Hi user42,
    with CVI 8.0, you cannot create or configure shared variables. However, you can read or write to an already configured LabVIEW 8.x shared variable from CVI using the DataSocket API.
    In order to do this you need to have and DataSocket 4.3 or higher installed.
    Here's a forum post about using the DataSocket functions a LabVIEW Shared Variables:
    http://forums.ni.com/ni/board/message?board.id=180&message.id=24569&requireLogin=False
    With CVI 8.1 and Measurement Studio 8.1 it's possible to use Shared Variables via the Network Varaiable Library (check out the end of the "Network-Published Shared Variable" section within the "Using the LabVIEW Shared Variable" documentation and the following link).
    Datasocket with LabWindows/CVI and LabVIEW Real-Time:
    http://digital.ni.com/public.nsf/allkb/CC4343488413A2F586256E6200099638?OpenDocument
    Daniel
    NIG

  • Coercion problem when using Shared Variable

    I have a curious coercion problem when using Shared Variables.  I want to share the state of a State Machine, which is an enum saved as a control (typedef) called TYPE State (see attached).  I create a shared variable called State and define it as a Custom Control, using the just-mentioned typedef.  So far, so good.  I've attached three simple VIs -- the first one, Init State, simply wires a constant to the input of the Shared Variable to initialize it -- the wired constant is, of course, defined by the typedef.  However, the Get State and Set State, meant to wire an indicator (for reading the state) or control (for setting it), develop coercion dots when wired into the Shared Variable.  Why?  How do I get rid of the dot?  [I suppose I could abandon my typedef and custom control, but the beauty of typedefs and custom controls is that it "enforces" rules, lets you use enums for clarity, keeps the code "honest", etc. -- I'd hate to give that up just to get rid of a dot!].
    On a related note, the code seems to work.  This is much too simplistic to do anything, but if you open Set State and Get State, set the state to anything, run it (it immediately stops, of course), then run Get State, you'll see the chosen state appear in the indicator.  So it does appear to work.  The "error" (coercion dot) may, I suppose, be a "bug" in Labview because it can't figure out the mapping of the (very simple!) Custom Control, but if so, I hope it gets fixed quickly!
    Bob Schor
    Attachments:
    Coercion Problem1.zip ‏38 KB

    Hello Bob,
    I am also seeing this behavior, I will escalate this question to our LabVIEW developers and post again here no later than next Tuesday, November 27th as National Instruments will be closed for the remainder of this week.
    If this issue does turn into a product suggestion, I would suspect the workaround would to live with the coersion dot for the time being.
    Enjoy the holiday
    Regards,
    Erik J.
    Applications Engineer
    National Instruments

  • IPhone has constant problems with Computer-To-Computer network

    I use a Computer-To-Computer network to connect my iPhone with my MacBook Pro when I'm at the office. This enables syncing of Things and OmniFocus between my iPhone versions of these programs and the versions on my MacBook Pro. I have one of the original (2G) iPhones. I daily go to my Airport icon on my Mac's menu bar, click on Create Network, and set up a password. I'm using 40-bit WEP.
    This sort of syncing procedure worked fairly well until iPhone OS 3.0. Ever since then, it's been completely unreliable. I've tried changing the channel a number of times, and of course rebooting both the iPhone and the computer dozens of times. It's still a problem.
    Anyone heard of this networking problem with 3.0? Any info appreciated! Thanks.

    yes, i have been having problems with computer to computer networking to iphone as well. for now, the only thing that keeps a steady connection is removing the sim card, so keep a paper clip handy.

  • I have a problem with iphone4 I bought a used and unlocked iphone4 old apple id because the first owner dies please help me how to activate iphone4 I unlocked with icloud

    I have a problem with iphone4
    I bought a used and unlocked iphone4
    old apple id because the first owner dies
    please help me how to activate iphone4
    I unlocked with icloud

    fherly nur arief wrote:
    I unlocked with icloud
    If you had already removed the device from 'Find My iPhone' in iCloud, then you jus tneed to powercycle the device in order to activate it.
    Source: http://support.apple.com/kb/TS4515
    "After the device is removed from the previous owner’s account, turn the device off by pressing and holding the Sleep/Wake button located on the top-right side of the device. Then restart your device and proceed with device setup as you would normally."
    If it has not been removed, then the activation lock is still active.
    If the previous owner cannot remove the device from their account there is nothing you can do unless the place you purchased it from will give you a refund.
    Activation Lock: http://support.apple.com/kb/ht5818
    What if I purchase a device that is still linked to the previous owner's account?
    Contact the previous owner as soon as possible and ask them to erase the device and remove it from their account. For complete instructions, read how to remove a device from a previous owner's account.
    How do I check for Activation Lock before purchasing a used device?
    When purchasing an iPhone, iPad, or iPod touch from someone other than Apple or an authorized Apple reseller, it is up to you to ensure that the device has been erased and is no longer linked to the previous owner’s account.
    Follow each of these steps to make sure that you can use the device you purchase:
    Turn the device on and slide to unlock.If the passcode lock screen or the home screen appears, the device has not been erased. Ask the seller to completely erase the device by going to Settings > General > Reset > Erase All Content and Settings. Do not take ownership of any used iPhone, iPad, or iPod touch until it has been erased.
    Begin the device setup process.After choosing a language, choosing a country, and connecting to a network, the device will begin activation. If you are asked for the previous owner’s Apple ID and password, the device is still linked to their account. Hand the device back to the seller and ask them to enter their password. If the previous owner is not present, they can remove the device from their account by signing in to icloud.com/find. Do not take ownership of any used iPhone, iPad, or iPod touch until it has been removed from the previous owner’s account.
    You will know that a device is ready for you to use when you are asked to “Set up your iPhone", “Set up your iPad", or “Set up your iPod” during the device setup process.

  • Problem with flash on IE11 after using adobe cleaner

    Problem with flash on IE11 after using adobe cleaner to remove a trial version of photoshop because there was not any entry on add/remove applications in windows 8.1
    Its to frustrating to reinstall everything. I tried everything from your support page with no luck…

    Link for Download & Install & Setup & Activation problems may help
    -Online Chat http://www.adobe.com/support/download-install/supportinfo/

  • Problem with Adobe Premiere Elements 12 using Scary Halloween template

    I'm having a problem with Adobe Premiere Elements 12 using Scary Halloween template under Menu Theme.  My problem is the red line is default to Scenes.  I would like it to default to Play.  How can I do that? Is it a bug?
    Side Note:  Other template default to Play Movie
    Thanks

    jeffrey caban
    No bug. Just the way the .psd for the Scary Halloween template was put together.
    You are going to have to get into the .psd for the Scary Halloween template and rearrange the
    Layer Sets. Do you know how to do that? If not, I will give you very specific instructions on how to
    do that.
    You want the order of the Layer Sets to look like
    That is what worked for me just now to get the disc menu Preview to open to the main
    menu with the red highlight under Play.
    We will be watching for your reply.
    ATR

  • I have the new iPad. Even with airplane mode on, my battery life is extremely limited. Is there a problem with the battery? I used to have the ipad2 and had no such problem.

    I have the new iPad. Even with airplane mode on, my battery life is extremely limited. Is there a problem with the battery? I used to have the ipad2 and had no such problem.

    What is your brightness setting & how many apps are open?
    The quickest way (and really the only way) to charge your iPad is with the included 10W USB Power Adapter. iPad will also charge, although more slowly, when attached to a computer with a high-power USB port (many recent Mac computers) or with an iPhone Power Adapter (5W). When attached to a computer via a standard USB port (most PCs or older Mac computers) iPad will charge very slowly (but iPad indicates not charging). Make sure your computer is on while charging iPad via USB. If iPad is connected to a computer that’s turned off or is in sleep or standby mode, the iPad battery will continue to drain.
    Apple recommends that once a month you let the iPad fully discharge & then recharge to 100%.
    How to Calibrate Your Mac, iPhone, or iPad Battery
    http://www.macblend.com/how-to-calibrate-your-mac-iphone-or-ipad-battery/
    At this link http://www.tomshardware.com/reviews/galaxy-tab-android-tablet,3014-11.html , tests show that the iPad 2 battery (25 watt-hours) will charge to 90% in 3 hours 1 minute. It will charge to 100% in 4 hours 2 minutes. The new iPad has a larger capacity battery (42 watt-hours), so using the 10W charger will obviously take longer. If you are using your iPad while charging, it will take even longer. It's best to turn your new iPad OFF and charge over night. Also look at The iPad's charging challenge explained http://www.macworld.com/article/1150356/ipadcharging.html
    Also, if you have a 3rd generation iPad, look at
    Apple: iPad Battery Nothing to Get Charged Up About
    http://allthingsd.com/20120327/apple-ipad-battery-nothing-to-get-charged-up-abou t/
    Apple Explains New iPad's Continued Charging Beyond 100% Battery Level
    http://www.macrumors.com/2012/03/27/apple-explains-new-ipads-continued-charging- beyond-100-battery-level/
    New iPad Takes Much Longer to Charge Than iPad 2
    http://www.iphonehacks.com/2012/03/new-ipad-takes-much-longer-to-charge-than-ipa d-2.html
    Apple Batteries - iPad http://www.apple.com/batteries/ipad.html
    Extend iPad Battery Life (Look at pjl123 comment)
    https://discussions.apple.com/thread/3921324?tstart=30
    New iPad Slow to Recharge, Barely Charges During Use
    http://www.pcworld.com/article/252326/new_ipad_slow_to_recharge_barely_charges_d uring_use.html
    Tips About Charging for New iPad 3
    http://goodscool-electronics.blogspot.com/2012/04/tips-about-charging-for-new-ip ad-3.html
    Prolong battery lifespan for iPad / iPad 2 / iPad 3: charging tips
    http://thehowto.wikidot.com/prolong-battery-lifespan-for-ipad
    In rare instances when using the Camera Connection Kit, you may notice that iPad does not charge after using the Camera Connection Kit. Disconnecting and reconnecting the iPad from the charger will resolve this issue.
     Cheers, Tom

  • We encountered a problem with some client machines that use Firefox version 24ESR and IE8. Ajax requests of aspx pages from Firefox are getting the following er

    I encountered a problem with some client machines that use Firefox version 24ESR and IE8.
    Ajax requests of aspx pages from Firefox are getting the following error from the iis server (iis version 7.5):
    Bad Request - Request Too Long
    HTTP Error 400. The size of the request headers is too long.
    From analyzing the request that was sent to the server, I saw that the request consist of only the viewstate of the aspx page.
    I tried to disable the viewstate for one page and the server got the request correctly.
    I do not encounter any issues on these laptops with postback requests from Firefox or when running the same application with IE8.

    Sometimes that means that the page address sent is loo long.
    Check the link address you are using.
    I can't help you further and will send for more help.

  • Communicating Between Multiple LabVIEW Executables on different computer using Shared Variables

    hi,
    I need to develop some executables which will be launched on different computer of a LAN. Some DATA are common. I need to share the data using shared variables.
    I usually used LabVIEW so I 'm familiar with shared variables but in this case, the RT target is a part of my
    project.
    I do I need to procceed in my case?
    thanks

    Ok but it's not my configuration and I haven't found my answer in the tutorial.
    You speak of a case where there is a computer and a RT target under the same LabView project. As I said earlier, I often use labview RT and shared variable between computer and RT target. But I assume here it's different.
    My question is : how do you acces to the SVE from 3 computers (without any RT target)? 
    1. If I create 3 labview projects using the same Shared Variable, do I need to use the same .lvlib on each project?
    2. Is it possible? 
    3. How can I configure where the SVE should be? When I use a RT target, It only depends where I put my Lvlib. But here there is 3 projects. 
    James
    Attachments:
    Sans titre.JPG ‏9 KB

  • How to use shared variables to address multiple Watlow controller​s on the same COM port

    Hello,
    I am trying to use LabVIEW 2010 to control 4 Watlow temperature controllers on one COM port. 3 are Model 96 and 1 is an EZ zone controller. Each controller has a unique modbus address, and I am trying to read from and write to individual registers (such as closed loop setpoint) using shared variables. I am getting return data when reading (although the data appears to be invalid), but am unable to change the value in the register by writing. How can I be sure that the Modbus server is sending commands to the correct controller?
    Chuck
    Solved!
    Go to Solution.

    Peter,
    Thanks for the reply. I have actually solved that problem. I realized that the Modbus server address has to be the same as the controller's Modbus address.
    I have, however, run into another problem. Perhaps you could help me with that. I have a system with 4 Watlow controllers, 3 are series 96 controllers, one is PID only and 2 are ramping. The 4th controller is an EZ zone. I am using RS485 for communications and the controllers are all wired in parallel for communications and power.
    I have set up 2 Modbus servers for 2 of the controllers.
    This is the first I have ever worked with Modbus based communications. I have successfully programmed using the Modbus read/write VIs, and am wanting to move to shared variables. My questions right now revolve around addressing, Modbus I/O servers and COM ports. Specifically, at this point, I know the addresses need to match up between the server and the slave device (Watlow controller in my case), how many servers can I create and use on one COM port? If the number is limited, is there a way I can specify an address that I want the server to talk to? Will the broadcast mode work to request data values from the controllers?
    I'd appreciate any information you can help me with, or if you could point me to some sort of concise 'How-To' for Modbus communication.
    Thanks.
    Chuck

  • Target VI stops before being commanded using shared variable

    All,
    I decided to post this in general since it deals mostly with shared variables however I am working with a RT target so feel free to move it to another forum.
    I originally posted a problem I was having with the RT Module Getting Started example, regarding the 1950679023 error, and trouble shooting led me to create the simplest test project I could think of. (I know you all want a link to the VIs but my company does not allow me to access internet file sharing sites to upload data so bare with me.)
    NOTE: This is NOT an RT project. Just deployed on an RT target.
    In Project Explorer I have Host.vi under " My Computer " and Target.VI and 3 networked-published shared variables (call them A,B,C here for simplicity) with RT-FIFO checked, under my RT target.
    Host.vi is a single while loop with a 0.5sec time delay express VI. The loop contains (along w/ the time delay) 1 numeric control wired to SV A, 1 numeric indicator wired to SV B, and finally a Stop button wired to SV C plus the conditional term (stop if True). SV A is configured as write, SV B as read, and SV C as write.
    Target.vi is a single while loop with a 0.5sec time delay express VI. The loop contains (along w/ the time delay) a numeric add function wired to a constant double and SV A configured as read. Also, SV C is wired to the conditional term configured as read (stop if True). The VI adds the two numbers, one of which is controlled by the Host.vi using SV A, and sends the results to Host.vi using SV B until the Stop button is pressed on Host.vi and sent back to Target.vi using SV C.
    I successfully ran this project (which included my always present 1950679023 error). Then changing no code but merely redeploying/running it again right after or through out the course of many other project deployments I get incorrect data on Host.vi. Basically sometimes it would work, sometimes it wouldn't; having changed NO code. First discovery was that Target.vi would automatically stop after running ~ 1sec since deploying/running on the target and before I could disconnect and open/run Host.vi. I then deployed/ran Target.vi with a probe on the wire between SV C and the conditional term and highlight execution running. After an average of 3 runs through the loop the SV C would automatically send out a True signal even though I never open/run Host.vi. How can shared variable C, which is write controlled by Host.vi, automatically change it's state like that when I never even open/run Host.vi?
    Another interesting observation is, If I first open/run Host.vi and then deploy/run Target.vi, the program ALWAYS works. But those steps go against my limit understanding of running VIs with shared variables on a target, which I got from NI's RT Module Getting Started Guide? I am going to have a hard time developing anything useful with these shared variables if I can not get the LV RT Guide example and this simple VI working. Any help would be great.
    Thanks
    JD
    P.S. I've noticed this error message a few times during deploying/running either the Host.vi or Target.vi. The error is not consistent; sometimes I see sometimes I don;t.:
    error-2147220727 (Hex 0x80040309)
    The client process cannot communicate with the configuration server process. If this problem persists please note the steps you performed that led to this error and contact technical support.
    PXI-1045,PXI-8196 RT,PXI-4220 (slot 2),(2) PXI-6259 (slot 3 and 4),PXI-5152 (slot 5),PXI-2585 (slot 6),PXI-5404 (slot 7)
    LV 8.2.1, RT 8.2, DAQmx 8.5, MAX 4.2, VISA 4.1,
    Pharlap OS ver.12.0, PH_EXEC ver. 8.2

    Thanks for the responses, (sorry this is going to be long)
    - First question is how do you initialize a shared variable (SV)? I don't have the DSC module, which I know has an initial value parameter. The SV is configured as a read and doesn't have any inputs, so am I missing something on the way to initialize it? I know the boolean defaults to False, which is good for my application. Also, right clicking on the SV doesn't bring up any obvious solution? Help if I am lost. Also, all my code is inside the loop (both the RT.vi and Host.vi), nothing is outside the loop.
    - I think I learned something through some trial and error. I made this test VI project even simpler by just having an incremental counter using shift registers inside the RT.vi while loop. The results of that counter are sent out, by way of a network-published SV, to the Host.vi. This network-published SV is located under the target within the Project Explorer. I temporarily got rid of the boolean SV, which was used to stop both the RT.vi and Host.vi. It was that boolean SV that gave me all the problems.
    This new test VI works consistently (also as a stand alone application, which was a first for me). My thoughts are that the issues had something to do with not "completely" removing all previous run instances of the VI and associated SVs/library from the RTs memory. I think I was getting old buffer data or SV corruption when, on my first test VI, would re-run the RT.vi and have the boolean SV inexplicitly switch states from False to True, even though the write controlled instance on Host.vi wasn't even running. I now undeploy everything (and check the Variable Manager) to make sure I have a clean sheet when re-running the VI. Now that brings up a question, is undeploying the only, or proper, way to clear the RT's memory?
    Anywho, I reintroduced the boolean SV into this new edition of the test project (read instance on RT.vi and write instance on Host.vi, while "hosted?" under the target in the Project Explorer) and everything works (although I still get that 1950679023 error once in a while when running for the first time). Meaning, I deploy the RT.vi then disconnect, then run the Host.vi and get valid data, then I press stop and both VI's stop. I then clear out the RT memory (I think all of it?) using undeploy and then repeat. Doing this I get consistent, valid results. If this seems like a learning experience for me please let me know, I don't want something to "work" just by accident. 
    - To answer the second reply: 1) all the SVs where created under the target in the Project Explorer. Also, I have not unchecked auto-deploy or tried deploying manually, but will give it a try. That brings up a great point, most of NI's data on SVs is "technical specification" like and not very in depth for something so complex. I have not been able to find any "tips/tricks" or "best practices", like trying to deploy manually. Is it because SVs are still new?? Also, a frustrating thing is that NI's step by step tutorials treat SVs like they are simple and fool proof, but following their instructions to the T I get errors. They leave out all the little nuances of correctly working with SVs and so it creates a steeper learning curve.  Enough of my rant.
    Thanks again for the responses and any more help to come.
    JD
    PXI-1045,PXI-8196 RT,PXI-4220 (slot 2),(2) PXI-6259 (slot 3 and 4),PXI-5152 (slot 5),PXI-2585 (slot 6),PXI-5404 (slot 7)
    LV 8.2.1, RT 8.2, DAQmx 8.5, MAX 4.2, VISA 4.1,
    Pharlap OS ver.12.0, PH_EXEC ver. 8.2

Maybe you are looking for

  • Header text in Script

    Hi, My SAP Script is maintained in English language. In one place, i have to read  header text which is in portuguese. I have used INCLUDE &VBDKR-TDNAME& OBJECT VBBK ID ZU04 PARAGRAPH HT in script. The text is read correctly which has maintained in E

  • Seesion issue with VO

    Hi, I am getting session issue in my application if i open my application in firefox and same time if i open application in IE (second session) ,data is not reflecting IE (second session) instead of data is coming whatever the first session(firefox)

  • HELP! My mums computer is being hacked?

    I am not a genius but do think I can tell that my mums macbookpro has got a viris or is being hacked. Lots of strange things have been happening to itand it i getting on my nerves. Strange things that have happend: (in order of time they took place)

  • Ad blocker for you tube is not blocking ads

    I installed the ad blocker that was listed for you tube. But I am still seeing ads. Is there something more I need to do?

  • Can't download Safari because Windows Installer can't be accessed

    Any help would be appreciated as to why by computer can't access Windows Installer? Thanks