NI CRIO 9073 doubt regarding compatibility

Hello,
             I have installed 2011 version of labview in one PC and on another PC I have 9.0 version. More, I would like to write a simple program in MODBUS RTU in such a way that can communicate with pressure sensor(Keller) that is already connected to a NI-CRIO 9073(version 10.0) module.
Problems have been faced..
1) When try to connect remotely to my CRIO 9073 from each PC, I gives an error message that the versions are not compatible. I had installed version of 2011 labview but still the CRIO 9073 is not connected to new verstion. Is there any special drivers for this.
2) I don't have modbus Vi options in my 2011 version. I downloaded MODBUS zip file from ni website but I am not sure how can I import that options into my labview functions pallet.
Thank you.

Hi Peter,
"but those two systems are giving compatible error."
That's what I summarized in my previous post. And I gave a hint on how to solve that.
"I am new to measurement and automation in labview."
That doesn't imply you don't need to read the documentation. You have a document coming with your cRIO that describes installation routines and you should be able to contact NI in case of bigger problems...
Best regards,
GerdW
CLAD, using 2009SP1 + LV2011SP1 + LV2014SP1 on WinXP+Win7+cRIO
Kudos are welcome

Similar Messages

  • Error While Reading a file Dynamicall​y in CRIO - 9073

    Hello all,
              I am using CRIO - 9073, here i transferred a file (With size of 5mb) through FTP from my PC..... and then i am trying to read it Dynamically, but while i am reading this file and updating, my CRIO going to stop mode...... So i can't workout more... Give a fine reply all...
    Regards
    Pandithan.

    What code for path building do you have running on the CRIO?
    Ton
    Free Code Capture Tool! Version 2.1.3 with comments, web-upload, back-save and snippets!
    Nederlandse LabVIEW user groep www.lvug.nl
    My LabVIEW Ideas
    LabVIEW, programming like it should be!

  • How to use SEA GSM Module on different slot of the cRIO 9073

    Hello to All,
    I have a SEA GSM+ Module on my cRIO 9073 at slot 7. I run the example program included in the resource CD as well as compiling the FPGA driver on my target but still don't work. Power supply is connected on the module. I don't know what I am missing. I followed strictly below steps as indicated in the read me text file but still nothing works. Please help.
    How to switch the FPGA Target on LabVIEW
    Complete the steps only if you use FPGA target other than 9104.
    1.  Add your new Compact RIO Target to the project
    1.  Add the new FPGA target below the cRIO-RT Target.
    3.  Drag the Gxxx folder from the original FPGA target and drop it into the new FPGA target. Make sure, that the module with its IOs, the FIFOs and the FPGA VI are integrated
    4.  Recompile the main VI - FPGA_App.vi, which is located in the Gxxx folder. A new bit file is created (.lvbit)
    5.  Open the Gxxx_Open.vi and select the just created bit file within the 'Open FPGA VI Reference.vi'.
    6.  Bind to TypeDef using ..Shared/Shared_TypeDefs.llb/Gxxx_FPGA_RefNum.ctl.
    7.  Close all VIs and do a "Save All, this project"
    Thanks in Advance,
    Joey

    Hello Jeff,
    The module is not working in any slot. Yes, I am using the sample code provided with the module name "Gxxx.lvproj". And also the FPGA is successfully compiled. Please see attached file for the error I received by the module.
    I already see this error in this forum and it was answered by powering the module by the external power supply. I already powered it. but still got an error.
    For the clarification, I am not using the  "SEA cRIO-Combo plus" module in the project rather I am using "SEA cRIO-GSM plus". I also attached the sren shotof the manual. I don't see any Toolkit Software manual in the resource CD and on the SEA website.
    Best Regards,
    Joey
    Attachments:
    GSM error.JPG ‏34 KB
    manual.JPG ‏91 KB

  • Binary to Voltage Conversion of encoder data on cRio 9073 using FPGA

    I am using FPGA with a cRio 9073 to acquire torque and absolute quadrature encoder values. It says in the FPGA instructions that the documentation for the 9073 should include the binary to voltage conversion, but when I looked at the documentation, it wasn't there. Where can I find the conversion value or function to convert binary encoder data back to voltage? The encoder is hooked up to an analog converter and is acquired with a 9215 AI (+-10V differential). Thanks

    There are individual formulas for one or a group of modules.
    LabView examples path:
    LabVIEW 2010\examples\CompactRIO\Basic IO\Analog Raw Host Calibration\AI Raw Host Calibration
    LabView help topic 
    Converting and Calibrating CompactRIO Analog Input Values (FPGA
    Interface)
    Best regards
    Christian

  • Is cRIO-9073 compatible with LabVIEW 8.5.1?

    I just received a cRIO-9073 and a cRIO-9074.
    When I configure them, both of them appear properly in MAX.
    When I add them to a LabVIEW project, the cRIO-9073 does not show its FPGA target. The cRIO-9074 does show it.
    I am using LabVIEW 8.5.1, is it compatible with the cRIO-9073?
    Thanks for any help.
    Michel
    Solved!
    Go to Solution.

    Hi Oswald,
    Thank you very much for the very prompt response. This should solve my problem.
    Also, after I read you message, I finally found the link to the software revision/compatibility file in the CompactRIO cRIO-9072/3/4 Operating Instructions and Specifications on page 3:
     "Notes Visit ni.com/info and enter the info code rdsoftwareversion to determine which software you need to use the cRIO-9072/3/4."
    Thanks again for your help
    Michel Lanthier

  • RT to HOST transfer rate problem in cRIO-9073 ?

    Dear Sir,
    Since past 2 months I am facing a problem in data transfer in cRIO 9073.
    I'm using two c series modules for data acquisition. NI 9205 for analog input and NI 9421 for digital input. Where Max sample rate of 9205 is 250kS/s.
    All seems perfect from FPGA to RT data transfer using FIFO. I m able to read instant value in RT when I change given input. In FPGA I m successfully reading and transferring 32 samples per 200us. In RT I m reading 16000 samles from FIFO and push it into shared variable. (No time out occurs in FIFO) therefore all I can say I m acquiring perfectly till RT. 
    But when I tries to transfer dta from RT to HOST, at  the time I m facing a problem. Host is updating 3-4 seconds late than RT. I have tried shared variable, TCP & Network steaming & faced same problem in all the cases.
    I m not able to get that where the problem is? Because I can see instant change as per input in RT. dont know what happened between RT to Host data transferring.
    Please do let me know what can be the possible reasons. Crossover Ethernet port or cable or chassis data transfer rate what can be the cause?????
    Regards,
    Pranav Parik
    Application Engineer
    Alliance Partner of National Instruments
    Attachments:
    RT.jpg ‏328 KB
    RT1.jpg ‏171 KB

    What is the priority of the VI you're running?  I'd be concerned that maybe you've starved out the ethernet transmit thread or something.
    -Danny

  • Doubt regarding SHDB transaction

    Hi All,   
                I have a doubt regarding the Process Tab in the application tool bar of SHDB transaction. What is the use of the following check boxes?
    1)       Default Size
    2)       Cont.after commit
    3)      not a batch input session
    4)      END: Not a Batch Input session
    5)      Simulate Background mode

    Hi,
    Basically these are the properties for CALL TRANSACTION using. You need not worry about these unless you really need those.
    1) Default Size: it will set the Default screen size for CALL TRANSACTION USING...
    2) Cont.after commit : it will set indicator that CALL TRANSACTION USING... is not completed by COMMIT. after commit also the process will continue
    3) not a batch input session: sets indicator that present session is not batch input
    4) END: Not a Batch Input session
    5) Simulate Background mode : session will be run in foreground. but similar to back grpund
    you can see the documentation by placing the cursor on these and click f1.

  • Error when running simulation with SIT 2010 on a cRIO 9073, what do I need to install on the cRio?

    Hi.
    I am trying to run a simulink model on a cRio 9073 using SIT 2010. I succesfully created the FPGA vi and the lvbit file in order to map input/outputs to the model. I also created the DLL and OUT for the model.
    When I run the interface VI on my computer, everything seems OK, until I get the following error and I am not able to run the simulation. I found a similar post earlier that suggests that I need to install the shared variable engine or the Simulation Interface Toolkit on my cRio. I tried to do both using MAX but could not find neither of the suggested installations.
    Thanks for the help!
    Items.viNI_SIT_driversupportVIs.lvlibIT Probe Model Items.vi loaded with errors on the target and was closed.
    LabVIEW:  Failed to load shared library SITs.*robeSignals:C. Ensure that the library is present on the RT target. Use MAX to install NI software or FTP to transfer custom libraries to the RT target.
    Items.viNI_SIT_driversupportVIs.lvlibIT Probe Model Items.vi loaded with errors on the target and was closed.LabVIEW:  Failed to load shared library SITs.*robeSignals:C. Ensure that the library is present on the RT target. Use MAX to install NI software or FTP to transfer custom libraries to the RT target.

    Hola jarcTec;
    Este tipo de error suena suele ocurrir cuando no se tienen las librerías apropiadas instaladas en el cRIO. Te recomendaría que abrieras MAX, debajo de la pestaña de Remote Systems selecciones tu dispositivo>> software, click derecho e instalar software. Aquí debes asegurarte que las librerías que te faltan estén instaladas en el cRIO. En Custom Installation selecciona SIT como opción para instalar en el cRIO tal y como se muestra en las imagenes.
    Espero esta información te sea de utilidad
    Exito en tu aplicación
    Marisol

  • I was looking at the "Find my iPhone" app and I have a doubt regarding how it works for the macbook. In order to detect the location, the macbook should remain signed into iCloud. What if the thief logs out of iCloud. Would we able to locate the macbook?

    I was looking at the "Find my iPhone" app and I have a doubt regarding how it works for the macbook. In order to detect the location, the macbook should remain signed into iCloud. What if the person who has stolen my macbook logs out of iCloud.
    It should work fine for iPhone/iPad because we can enable "Restrictions" to prevent the user from signing out of iCloud. Do we have simialr settings for the macbook?
    Thanks,

    If it's not on the device list, it indicates that someone has gone to Find My iPhone on icloud.com and manually deleted it from the device list (as explained here: http://help.apple.com/icloud/#mmfc0eeddd), and it has not gone back online since (which would cause it to reappear on the device list; Find My iPhone has been turned of in settings on the device; the iClolud account has been deleted from the device; or the entire devices has been erased and restored.
    Unfortunately, there's no other way to track the phone other than through Find My iPhone.  You could call your carrier and see if they would blackliste it so at least the theif couldn't use it.

  • How can I diagnose a Labview RT program crash on cRIO 9073?

    I have 2 cRIO 9073 purchased about 1 year apart.  Both are running the same realtime application.  The first cRIO runs fine.  The 2nd cRIO crashes intermittently while executing 1 particular VI that contains 2 timed loops running in parallel (1 collecting data and the other controlling machine movement).  When it crashes, the app stops, web server and FTP stop responding, MAX cannot communicate with the device ( I must perform a hard reset).  After reset, viewing the error log using MAX shows no errors.  I've added message logging to see if it stops in a particular place, but see no patterns.  In some cases, the device seems to be continually restarting (every 2-3 minutes) until it finally hangs.  In many instances, my configurations files (used to store runtime variables) have been corrupted or erased.  When trying to deploy the app on this Rio, I generally must try multiple times because I receive the error, "Error deploying on target".  I have tried formatting the flash and reinstalling the OS many times from different sources.
    I'm running Labview 2009, SP1 with the FPGA option. 
    Any ideas on how to diagnose this problem?  Are there any diagnostic tools to test this device?

    Here's a better description of what I'm trying to do.  This system is used to control the head position on a test machine.  I used the LV RT wizard to create the base VI with 1 deterministic loop and 1 non-deterministic.  The deterministic loop schedules 2 different test.  Test 1 is every 5 minutes (collect analog data, read temperatures, calculate new head position based on temperature , drive stepper motors to new position, collect data after moving, then dismiss).  Test 2 runs once a day with a duration of about 4.5 hours (drive stepper motors to user defined position, simulatiously collect data at various rates from 5Hz to .01 Hz, drive head to next user defined position, etc). This test has 2 timed loops running at different rates, one collects data, the other moves the head and acts as a timer to know when to move to the next position.
    If I never run test 2, then the system has never crashed, leading me to believe the problem is in the test 2 VI.  The crashes don't necessarly occur in the Test 2 VI.  On some occations 1-2 hours after Test 2 has completed, the CRIO will start rebooting itself (every 2-3 minutes).  This may happen 4-5 times until it will finally hang completely. 
    Since the crashes happen randomly (it may run for 2-3 days before crashing) I'm trying to find some way of trapping  errors or exceptions that would give me some clue as to what the problem may be. 

  • Not able to create OUT file with "nidll_vxworks" in Matlab for use with the LabVIEW SIT 2010 and a cRio 9073, sh.exe error

    I am trying to compile an OUT file for my Simulink model using "nidll_vxworks" and run it using the Simulation Interface Toolkit for a cRIO 9073 . I am able to compile the DLL file using "nidll" and succesfully run the simulation using my PC as the host.
    I already downloaded the "gccdist" and "vxworks61gccdist" folders and copied them to "c:" When I build the model in Sumulink I get the following error at the end of the process (at the same time windows tells me that "sh.exe" has stopped working). If it matters I am running Windows 7 64bits, but using Matlab 2009b 32bits and LabView 2010 32 bits. ANY HELP WILL BE APPRECIATED. "QofV" is the name of my Simulink model and I changed to "XXX" parts of the file path.
    ### Linking ...
    rm -f "QofV.out" ctdt.c;nmppc QofV.o QofV_data.o rtGetInf.o rtGetNaN.o rt_logging.o rt_look.o rt_look1d.o rt_nonfinite.o  nidll_main.o rt_sim.o ode8.o    | tclsh c:/gccdist/WindRiver/vxworks-6.3/host/resource/hutils/tcl/munch.tcl -c ppc > ctdt.c 
    abnormal program termination 
    C:\Users\XXX\AppData\Local\Temp\make426012.sh: fork failed: no child processes [1]
    make: *** [QofV.out] Error 1 
    ### Real-Time Workshop build procedure for model: 'QofV' aborted due to an error.
    >> 
    ### Linking ...rm -f "QofV.out" ctdt.c;nmppc QofV.o QofV_data.o rtGetInf.o rtGetNaN.o rt_logging.o rt_look.o rt_look1d.o rt_nonfinite.o  nidll_main.o rt_sim.o ode8.o    | tclsh c:/gccdist/WindRiver/vxworks-6.3/host/resource/hutils/tcl/munch.tcl -c ppc > ctdt.c  
    abnormal program termination 
    C:\Users\XXX\AppData\Local\Temp\make426012.sh: fork failed: no child processes [1]make: *** [QofV.out] Error 1 ### Real-Time Workshop build procedure for model: 'QofV' aborted due to an error.>>
    ### Linking ...rm -f "QofV.out" ctdt.c;nmppc QofV.o QofV_data.o rtGetInf.o rtGetNaN.o rt_logging.o rt_look.o rt_look1d.o rt_nonfinite.o  nidll_main.o rt_sim.o ode8.o    | tclsh c:/gccdist/WindRiver/vxworks-6.3/host/resource/hutils/tcl/munch.tcl -c ppc > ctdt.c  abnormal program termination C:\Users\XXX\AppData\Local\Temp\make426012.sh: fork failed: no child processes [1]make: *** [QofV.out] Error 1 ### Real-Time Workshop build procedure for model: 'QofV' aborted due to an error.>> 
    Solved!
    Go to Solution.

    Hello jarcTec,
    I am not sure right now if you can do it, but this tutorial might help, also everything was made in Winddows 7 in this one.
    http://zone.ni.com/devzone/cda/tut/p/id/11654
    Take a quick look and let me know if it works!!!
    Luis Fernando
    National Instruments Cono Sur
    Ingeniería de Campo y Consultoría
    http://chile.ni.com/

  • Very urgent: Doubts regarding CRM WORKFLOW OF BUSINESS PARTNER CREATION

    HI ,
    I HAVE DOUBTS REGARDING CRM WORKFLOW OF BUSINESS PARTNER CREATION, WHILE I AM CREATING BUSINESS PARTNER THROUGH R/3 , IT REFLECT IT INTO MYSAP CRM ALSO, AT THAT TIME IT SENDING THE MAIL TWICE TO THE RECEIPIENT. IS THERE ANY WAY THROUGH  WHICH I CAN RESTRICT IT TO SEND THE MAIL ONLY ONCE,
    PLZ SEND ME THE REPLY AS SOON AS POSSIBLE,
    THANKS  ADVANCED,

    HI
    WORKFLOW SEETING. SAP MAIL
    MULTIPLE MAILS AND
    ONLY ONCE CHOOSE
    ONLY ONCE OPTION ON WHICH VERSION U R WORKING?
    REWARD IF HELPFUL
    VENKAT

  • Doubt regarding  ALE SETTINGS in IDOC scenario.

    Hi Friends,
            I have some doubts regarding ALE settings for IDOC scenarios,  can anyone  please clarify my doubts.
    For exmaple take IDOC to FILE scenario
    The knowledge i got from SDN is --
    One need to do at the  R3 side is  --- RFC DESTINATION (SM59)  for the XI system.
                                                       --- TRFC PORT  for sending IDOC  to the  XI system
                                                       --- CREATING LOGICAL SYSTEM
                                                       --- CREATING PARTNER PROFILE 
                   at the XI side is  --- RFC  Destination ( For SAP sender system)
                                           --- CREATING  PORT  for receiving IDOC from the SAP sending system(IDX1).
    1. Do we create two logical systems for both Sender ( R3 system ) and Receiver( XI system ) in R3 system itself or in XI system or in both systems we create these logical systems? Is this a mandatory step in doing ALE configurations?
    In IDOC to IDOC scenario-------
      2.  Do we craete two RFC destinations in XI system? One RFC DESTINATION for the Sender R3 system and another RFC DESTINATION for the Receiver R3 System? and do we create RFC DESTINATION for the XI system in receiver R3 system? If not.....y we don't create like this........Please give me some clarity on this.............
      3.  If we use IDOC adapter ,since IDOC adapter resides on the ABAP STACK ,we don't need sender communication channel ,for the similar reason----
    y we r creating receiver communication channel in the case of FILE to IDOC scenario?
      4. Can any one please provide me the ALE settings for IDOC to FILE scenario,
                                                                                    FILE to IDOC scenario,                                                                               
    IDOC to IDOC scenario individually.
    Thanks in advance.
    Regards,
    Ramana.

    hi,
    1. Yes, we create two logical systems for both Sender ( R3 system ) and Receiver( XI system ) in R3 system itself and
    it is a mandatory step in doing ALE configurations
    2. We create 1 RFC destination each in R3 and XI.
        R3 RFC destination points to Xi and
        XI RFC destination  points to R3
    3 We need to create Communication Channel for Idoc receiver as the receiver channel is always required but sender may not be necessary
    4. ALE settings for all IDOC scenarios are same  as follows....
    Steps for ALE settings:-
    Steps for XI
    Step 1)
         Goto SM59.
         Create new RFC destination of type 3(Abap connection).
         Give a suitable name and description.
         Give the Ip address of the R3 system.
         Give the system number.
         Give the gateway host name and gateway service (3300 + system number).
         Go to the logon security tab.
         Give the lang, client, username and password.
         Test connection and remote logon.
    Step 2)
         Goto IDX1.
         Create a new port.
         Give the port name.
         Give the client number for the R3 system.
         Select the created Rfc Destination.
    Step 3)
         Goto IDX2
         Create a new Meta data.
         Give the Idoc type.
         Select the created port.
    Steps for R3.
    Step 1)
         Goto SM59.
         Create new RFC destination of type 3(Abap connection).
         Give a suitable name and description.
         Give the Ip address of the XI system.
         Give the system number.
         Give the gateway host name and gateway service (3300 + system number).
         Go to the logon security tab.
         Give the lang, client, username and password.
         Test connection and remote logon.
    Step 2)
         Goto WE21.
         Create a port under transactional RFC.(R3->XI)
         Designate the RFC destination created in prev step.
    Step 3)
         Goto SALE.
         Basic settings->Logical Systems->Define logical system.
         Create two logical systems(one for XI and the other for R3)
         Basic settings->Logical Systems->Assign logical system.
         Assign the R3 logical system to respective client.
    Step 4)
         Goto WE20.
         Partner type LS.
         Create two partner profile(one for XI the other for R3).
         Give the outbound or inbound message type based on the direction.
    Step 5)
         Goto WE19
         Give the basic type and execute.
         fill in the required fields.
         Goto IDOC->edit control records.
         Give the following values.(Receiver port,partner no.,part type and sender Partner no. and type)
         Click outbound processing.
    Step 6)
         Go to SM58
         if there are any messages then there is some error in execution.
         Goto WE02.
         Check the status of the IDOC.
         Goto WE47.
         TO decode the status code.
    Step 7)
         Not mandatory.
         Goto BD64.
         Click on Create model view.
         Add message type.
    BD87 to check the status of IDOC.
    In case if not authorized then go to the target system and check in SU53, see for the missing object
    and assign it to the user.
    SAP r3
    sm59(status check)(no message)
    WE02(status check)
    WE05(status check)
    BD87(status check)
    Xi
    IDx5(Idoc check)
    SU53(authorization check)
    Reward points if helpful
    Prashant

  • Doubt Regarding validation of IDOCS

    Hi Gurus,
               I have some doubts regarding IDOCS.
    1. If we are sending a IDOC from XI to R/3, where does we do validations from R/3 side and how do we do that.  Suppose if we are sending a Purchase order IDOC form XI to R/3, how to do validations for that particular IDOC for PO number and some other fields  from R/3 side.
    2. Do we need to do validations in a aABAP Program.
    please clarify me these Questions. Thanks in advance..
    santosh.

    Hi Santhosh,
    If you want to do any validations in ur IDOC,then from XI just push the IDOC,dont post it.
    (ie)Send the IDOC from XI in status 64 :IDoc ready to be transferred to application.
    Once R/3 Received this status then thru your ABAP progream just get this IDOC no: and do the validations then Post the IDOC manually.
    Thanks.
    Note:Reward Points if you find useful.

  • Varying ON time pulse train generation using NI cRIO-9073 and NI 9401 module

    Hi,
              I am a beginner to the Labview environment.  Am using NI cRIO-9073 and NI 9401 module; and NI Labview 2013. I want to generate 64 pulses, wherein the ON time of the pulses are varying as shown below. The Pulses need to have a constant period of about 34µs. The pulses should have a constant amplitude anywhere from 5 to 10V. I am trying to do the same in FPGA interface mode but failing to do so. Please advise me..... Please also suggest pdf and video resources to learn Labview programming.
    Pulse ON Time
    18 µs
    19 µs
    20 µs
    21 µs
    22 µs
    23 µs
    24 µs
    25 µs
    26 µs
    27 µs
    28 µs
    29 µs
    30 µs
    31 µs
    32 µs
    33 µs
    33 µs
    32 µs
    31 µs
    30 µs
    29 µs
    28 µs
    27 µs
    26 µs
    25 µs
    24 µs
    23 µs
    22 µs
    21 µs
    20 µs
    19 µs
    18 µs
    17 µs
    16 µs
    15 µs
    14 µs
    13 µs
    12 µs
    11 µs
    10 µs
    09 µs
    08 µs
    07 µs
    06 µs
    05 µs
    04 µs
    03 µs
    02 µs
    02 µs
    03 µs
    04 µs
    05 µs
    06 µs
    07 µs
    08 µs
    09 µs
    10 µs
    11 µs
    12 µs
    13 µs
    14 µs
    15 µs
    16 µs
    17 µs

    t81,
    It is possible to make frequency measurements with either the 9422 or the 9425 but each will have its own limitations in the range of frequency it will be able to accurately measure.  
    A few things to know:  
    1. What are the frequency ranges for each sensor (tach and MFM)? More than just knowing Hz/kHz will be helpful.
    2. To what accuracy do you need to measure these signals?
    The 9422 supports a specialty digital configuration counter input that can be configured for frequency measurement (see link)
    http://zone.ni.com/reference/en-XX/help/372603F-01​/riohelprt/crio-9422_rt/
    The specialty mode is only available when using Scan Interface mode, not with FPGA.  
    But the max clock rate in the specifications for the 9422 is 4kHz so this may not be sufficient for the tachometer.  I believe this is the max rate at which the module will update its state no matter how fast the underlying software (RT controller) is running.
    The 9425 has a higher clock rate (~140kHz) but doesn't support the specialty digital mode mentioned above.  It is also a software timed only device but this shouldn't be a problem if you use FPGA.
    Dan

Maybe you are looking for

  • How can I see a list of the assets associated with a sequence?

    How can I see a list of the assets, both online and offline, associated with a sequence?

  • ITunes 10.1 (64-bit) slow performance

    Hello all, I have recently bought a new pc, a very fast machine (see details below), but I'm experiencing bad performance with iTunes 10.1 (64-bit) for windows. I don't have a lot of stuff in iTunes, I have about 120 apps, 500 songs, 1200 photos, cou

  • Down Payment Request Error (F-47)

    Hello All, I am trying to create a Down Payment request in F-47, which I am unable to do it as I get an error which says "<b>Down payments with taxes are not permitted when processing with jurisdiction code</b>". Please give me your valuable suggesti

  • How to create the logon Screen in details ?

    Hi Experts, i have the problems in logon screen in portal but am trying to in change the rename of com.sap.portal.runtime.logon.par.bak but is not change  in the display in portal logon screeen User id : Password : Authendication Schema: Drop down Bo

  • Reg : Smartform translation

    Hi, In our smartform we are trying to print this French text  “mise en œuvre” , but Adobe is having problem in reading this special character "œ ", so it prints as # . Please suggest some solution to overcome this . Thanks & Regards, Keerthi vasan.M