Hi,
I was hoping someone might be able to clarify the SAP GUI scripting requirements for using the NWBC side panels. In the help documentation it states:
As of NWBC 3.5 patch level 6 or NWBC 4.0 and SAP GUI 7.20 patch level 13 or 7.30 final release, it is no longer necessary to enable SAP GUI Scripting on the client PC, except if you are using Property Collector. That means, it is no longer necessary to enable front-end scripting through registry key (HKLM and HKCU) for using side panels in NWBC. However, it is still necessary to install SAP GUI Scripting and to enable it for the server (at least read-only).
Some of our users are getting pop up messages that say "The scripting support is not installed"... interestingly they don't actually appear to be opening a side panel when they get this message.
I noticed that these users don't actually have SAP GUI scripting installed at all, so not that it is just not enabled, it is not installed in these cases. So does the above section from the help documentation mean that SAP GUI scripting must be installed on the client PC but it does not actually have to be enabled?
That's how I am currently reading it... but perhaps someone can clarify for me, or someone else has had a similar experience.
Thanks,
Simon

Hi Simon,
As written in the documentation you quoted:
Simon Kemp wrote:
Hi,
I was hoping someone might be able to clarify the SAP GUI scripting requirements for using the NWBC side panels. In the help documentation it states:
As of NWBC 3.5 patch level 6 or NWBC 4.0 and SAP GUI 7.20 patch level 13 or 7.30 final release, it is no longer necessary to enable SAP GUI Scripting on the client PC, except if you are using Property Collector. That means, it is no longer necessary to enable front-end scripting through registry key (HKLM and HKCU) for using side panels in NWBC. However, it is still necessary to install SAP GUI Scripting and to enable it for the server (at least read-only).
Meaning: SAP GUI Scripting need to be installed on the client PC, although it is not required to activate it:
Regards,
Claudia

Similar Messages

  • Difference between SAP GUI scripting and eCATT

    HI,
      What is difference between SAP GUI Script and eCATT.
      I know that SAP GUI Script can be used for transaction that have activex controls but can we use these script in eCATT also.
      If yes, how?
    Thanks,
    Priya

    Hi Priya,
    SAPGUI script will only work from an external program, may be VB or vbScript. ECATT can only execute a fixed set of commands e.g. (TCD, SAPGUI etc) or a block of ABAP code. ECATT can both work in foreground and background mode.
    In foreground mode you would be able to see the script running on your frontend whereas background mode will create a job in the SAP system.
    You can convert your SAPGUI scripts to SAPGUI commands and execute. If you strictly want to execute SAPGUI script from ECATT then you would have to save the script somewhere on your desktop computer and call it from an ABAP block in ECATT.
    Bikash

  • SAP GUI Scripting Wizzard Windows7 does not work

    Dear Experts,
    I am quite a novice when it comes to SAP GUI scripting (let alone any other development), therefore my question might be rather stupid. After my PC was migrated from XP to Windows 7 it is no longer possible to use the SAP GUI scripting wizzard. When you select it from the menue, simply nothing happens.
    Does anyone have an idea what I need to do to have this useful tool back on my PC?
    We are running SAP GUi 7.1
    Thanks for your help
    Theo

      Here is SAP GUI wizard replacement tool...its in auto IT - enjoy
    http://www.autoitscript.com/forum/topic/149540-sapwizardudf/
    I had the tech guys here install ,  the latest GUI patch level 15,
    and the script development tools not working issue has been fixed
    They (SAP?) removed the 'script development tools' menu option!?
    I have not installed the MS hotfix, but
    My question is,  it true the 'Script development tools' is gone?
    Other methods
    a) This (free) non SAP solution seems to work however...any other ideas?
    Scripting Tracker Lite
    http://scn.sap.com/docs/DOC-32728
    b) The Activate GuiXT tool in SAP GUI also does give you some clues in the element window
    and could be an alternative way , to get control names.
    eg a radio button is R[P_CONTROL_ID] when it should be radP_CONTROL_ID
    c) The SAP script recording and playback ,  to a vbs script will give you the control names also, if you edit the script.
    You must of course have GUI scripting on in rz11
    I can't read this note https://service.sap.com/sap/support/notes/1633639 - need a password!

  • SAP GUI Scripting: Script Is Running.....Help!

    Hello all,
    I'm new to the forums and have an SAP question problem. I'm an end user of SAP and have been using it since 2002. A couple of weeks ago when I logged into SAP I noticed a red/white icon in the lower right corner of my screen. When I hover over it it says "SAP GUI Scripting: Script Is Running". The problem is, I have never created a script. When I start working in SAP I have noticed a lot of the screens have a different format now and I get a lot of ABAP errors.
    After doing some research I found under "Customize Local Layout", "Options" I can uncheck the box "Enable Scripting". I click "Apply" and "OK". Now the red/white icon goes away in the lower right corner and all my screens go back to normal with no ABAP errors.
    The problem now is that every minute or two I get a pop up window that says "Scripting support is disabled by the user".
    Has anyone else had this problem?
    1. I've never created a script. Why is one running now?
    2. Is there a way to stop the pop up message "Scripting support is disabled...." if I uncheck "Enable Scripting"?
    Thanks for any feedback

    Here's the properties of the connection....
    http://www.lstwo.com/images/97735141499811194923.jpg
    http://www.lstwo.com/images/27092678568585605702.jpg
    http://www.lstwo.com/images/02572789823840845106.jpg
    Here's the properties of the desktop icon....
    http://www.lstwo.com/images/36703668322706084468.jpg
    http://www.lstwo.com/images/40729387005252851113.jpg
    http://www.lstwo.com/images/48149337890555671928.jpg
    I agree, I'm stumped. I even tried looking through the SAP entries in my registry to see if I could find anything. It's a bit confusing but I didn't see anything out of place.

  • Executing SAP GUI Script From a Web Page

    I have an issue when trying to execute some javascript (sap gui script) from a webpage. 
    When the javascript is executed I get the message:
    automation server unable to create object. 
    However, this exact same javascript when placed in a text file and double-clicked executes just fine through the windows scripting host. 
    Does anyone have an example of gui script code executing from a webpage?  Or any ideas on why it isn't working from the webpage?  Both scenarios should be executing the code on the local machine through WSH.
    Below is the javascript as well as the webpage executing the javascript:
    SAPGUI SCRIPT
    if (typeof(application) == "undefined")
       sapgui      = GetObject("SAPGUI");
       application = sapgui.GetScriptingEngine;
    if (typeof(connection) == "undefined")
       connection = application.children(0);
    if (typeof(session) == "undefined")
       session = connection.children(0);
    if (typeof(WScript) != "undefined")
       WScript.connectObject(session, "on");
       WScript.connectObject(application, "on");
    session.findById("wnd[0]").maximize();
    session.findById("wnd[0]/tbar[0]/okcd").text = "/nzsd1067";
    session.findById("wnd[0]").sendVKey(0);
    session.findById("wnd[0]/usr/ctxtVBAK-KUNNR").text = "6343";
    session.findById("wnd[0]").sendVKey(0);
    WEBPAGE
    <!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
    <html>
         <head>
              <title></title>
              <meta name="GENERATOR" content="Microsoft Visual Studio .NET 7.1">
              <meta name="vs_targetSchema" content="http://schemas.microsoft.com/intellisense/ie5">
              <! INPUT PARAMETER SETTINGS:
              To Push data to Siebel or SAP the appropriate
              field below must be set = TRUE.
              Pop_SAP
              Pop_Siebel
              SIEBEL INPUT PARAMETER: When
              Pushing data to a Siebel screen the Query_Type should be set based on the type
              of lookup that is requested.
              Query_Type = 'SAP' -presents a screen based on a customer SAP Id.
              Query_Type = 'SR' -presents a screen based on a Service Request.
              Query_Type = '' or null -presents a search screen to locate the proper contact in Siebel
              APP_SAP_ID -SAP customer Id
              APP_SR_NUM -Siebel Service Request Number
              >
    <SCRIPT LANGUAGE="VBScript">
    Sub LoadContact()
            'Siebel Application Object
            Dim siebApp 'As SIEBELHTMLLib.ISiebelHTMLApplication
            Dim siebSvcs 'As SIEBELHTMLLib.ISiebelService
            Dim siebOutputPropSet 'As SIEBELHTMLLib.ISiebelPropertySet
            Dim siebInputPropSet 'As SIEBELHTMLLib.ISiebelPropertySet
            Dim bool 'As Boolean
            Dim errCode 'As Integer
            Dim errText 'As String
            Dim QueryType 'As String
         Dim PopSAP 'As String
         PopSiebel = "TRUE"
         If PopSiebel = "TRUE" Then
              QueryType = "SAP"
              If QueryType = "null" Then
                   QueryType = ""
              End If
                 'Create The SiebelHTML Object      
                 set siebApp = CreateObject("SiebelHTML.SiebelHTMLApplication.1")  
                 If Not siebApp Is Nothing Then
                     'Create A New Property Set
                     set siebInputPropSet = siebApp.NewPropertySet
                     set siebOutputPropSet = siebApp.NewPropertySet
                     If Not siebInputPropSet Is Nothing Then
                         siebInputPropSet.SetProperty "ANI", "9738986011"
                         siebInputPropSet.SetProperty "SAP_ID", "0000516616"
                         siebInputPropSet.SetProperty "SR_NUM", "null"
                         siebInputPropSet.SetProperty "Interaction_ID", "168608840053"
                         siebInputPropSet.SetProperty "Query_Type", QueryType
                     Else
                         errCode = siebApp.GetLastErrCode
                         errText = siebApp.GetLastErrText
                             MsgBox "Could not Create Siebel Property Set: " & errCode & "::" & errText
                     End If
                     'Get A Siebel Service
                     set siebSvcs = siebApp.GetService ("TAWBS")
                     If Not siebSvcs Is Nothing Then
                         siebSvcs.InvokeMethod "TAWPresentAccount", siebInputPropSet, siebOutputPropSet
                  Else
                         errCode = siebApp.GetLastErrCode
                         errText = siebApp.GetLastErrText
                   MsgBox "Could not Get Siebel Service: " & errCode & "::" & errText
                         End If
                     set siebApp = Nothing
                 End If
                 set siebInputPropSet = Nothing
                 set siebOutputPropSet = Nothing
                 set siebSvcs = Nothing
         End If 
    End Sub
    </SCRIPT>
    <SCRIPT LANGUAGE="javascript">
    function loadSAP()
         if (typeof(application) == "undefined")
              sapgui      = GetObject("SAPGUI");
              application = sapgui.GetScriptingEngine;
         if (typeof(connection) == "undefined")
              connection = application.children(0);
         if (typeof(session) == "undefined")
              session = connection.children(0);
         if (typeof(WScript) != "undefined")
              WScript.connectObject(session, "on");
              WScript.connectObject(application, "on");
         session.findById("wnd[0]").maximize();
         session.findById("wnd[0]/tbar[0]/okcd").text = "/nzsd1067";
         session.findById("wnd[0]").sendVKey(0);
         session.findById("wnd[0]/usr/ctxtVBAK-KUNNR").text = "0000516616";
         session.findById("wnd[0]").sendVKey(0);
    } // end
    </SCRIPT>
    </head>
         <body onload="loadSAP()">
              <H3><FONT face="Arial" size="5">Raytheon Integration Screen</FONT></H3>
              <HR style="WIDTH: 882px; HEIGHT: 8px" color="#3366cc" SIZE="8">
              <form id="ValidForm" onsubmit="LoadContact(); return false;" language="jscript">
                   <FONT face="Arial">Load Siebel Screen</FONT> <! <input name="Text1" TYPE="TEXT"
                   SIZE="10" ID="Text1"> <input name="Submit" TYPE="submit" VALUE="Submit" ID="Submit1">
              </form>
              <form id="Form1" onsubmit="loadSAP(); return false;" language="javascript">
                   <FONT face="Arial">Load SAP Screen</FONT>    <! <input
                   name="Text2" TYPE="TEXT" SIZE="10" ID="Text2"> <input name="Submit" TYPE="submit" VALUE="Submit" ID="Submit2">
              </form>
         </body>
    </html>

    Hi Bernd,
    the following code works in VBS. If you run saplogon.exe you'll get a message box saying '/app'.
    Set Wrp = CreateObject ("SapROTWr.SapROTWrapper")
    Set SapGui = Wrp.GetROTEntry ("SAPGUI")
    Set application = sapgui.GetScriptingEngine
    MsgBox application.id
    I haven't tried it on a web page, but I don't see why it shouldn't work there. Ok, maybe the MsgBox is command is not available.
    Best regards,
    Christian

  • Adding *SAP Gui Scripting* in windows 2003

    Hi,
    we r devloped some z programs, and it is displayed properly in client desktp (XP). But it is not displyed properly in (OS) Windows 2003 server.
    So i added SAP Gui Scripting through Gui instalation and it displyed ok. But at same time my SAP Logon pad will hide from my desktop.
    So again i installed my SAP gui with
    1. SAP Gui Suite
    2. R/3 Add-on
    3. General Add-on
    Again same problem that is not visible when i am adding SAP Gui Scripting saplogon pad will automatically hide from my desktop.
    GUI version 7.10
    What could be resons?
    Regards
    Edited by: manoj nayak on Apr 6, 2010 9:51 AM
    Edited by: manoj nayak on Apr 6, 2010 10:18 AM

    Hi,
    Can u give more information how to troubleshot this one?
    And why after install (add) of SAP GUI SCRIPT SAP logon pad will automatically remove from desktop?
    Error:
    The system cannot find the file specified.
    Destination:
    C:\Program Files (x86)\SAP\FrontEnd\sapgui\wwi\wwilabel.exe
    Error-Code:
    2147024894
    Any idea?
    Regards.

  • Difference between using the Enterprise Portal and SAP GUI

    Hi Gurus,
    Could one of you please send me a document that lists the differences between the Enterprise Portal and SAP GUI?
    thanks in advance

    Hi,
    For groups, managedBy is an administrative convenience to designate “group admins”. Whatever principal listed in
    managedBy gets permission to update a group’s membership (the actual security is updated on the group’s AD object to allow this).
    In Win2008 and later managedBy also became the way you delegated local administration on an RODC, allowing branch admins to install patches, manage shares, etc. (http://technet.microsoft.com/en-us/library/cc755310(WS.10).aspx). 
    On the RODC, this is updating the RepairAdmin registry value within RODCRoles.
    So the difference between them should be only the way they do the same thing.
    For more details, please refer to the below article:
    http://blogs.technet.com/b/askds/archive/2011/06/24/friday-mail-sack-wahoo-edition.aspx
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • Variables in a SAP GUI Script

    Hi All,                                                                                -
    Can somebody tell me, how can I use a variable instead of hardcoded value into a SAP GUI script?
    Because the recorded file is a vbs-file, I have tried to declare a variable as usual:
    Dim Count As Integer
    Count  = 58
    But when I try to execute the updated script, even without assigning the Count variable to any places from the script, an error occurs u2013 u2018expected end of statementu2019 (the same error also occurs if I use Count instead of 58). Actually I want to replace all occurrences of number 58 in the script below. Can anybody help me?
    Thanks,
    Svetlana
    If Not IsObject(application) Then
       Set SapGuiAuto  = GetObject("SAPGUI")
       Set application = SapGuiAuto.GetScriptingEngine
    End If
    If Not IsObject(connection) Then
       Set connection = application.Children(0)
    End If
    If Not IsObject(session) Then
       Set session    = connection.Children(0)
    End If
    If IsObject(WScript) Then
       WScript.ConnectObject session,     "on"
       WScript.ConnectObject application, "on"
    End If
    session.findById("wnd[0]").maximize
    session.findById("wnd[0]/usr/tabsTS_SCRIPT_EDITOR_0202/tabpECSC_ED/ssubTR_SCRIPT_REF1:SAPLECATT_MAIN:0402/cntlCC_ECSC_EDITOR/shellcont/shell/shellcont[1]/shell/shellcont[1]/shell/shellcont[1]/shell/shellcont[1]/shell").contextMenu
    session.findById("wnd[0]/usr/tabsTS_SCRIPT_EDITOR_0202/tabpECSC_ED/ssubTR_SCRIPT_REF1:SAPLECATT_MAIN:0402/cntlCC_ECSC_EDITOR/shellcont/shell/shellcont[1]/shell/shellcont[1]/shell/shellcont[1]/shell/shellcont[1]/shell").currentCellColumn = "DATA"
    session.findById("wnd[0]/usr/tabsTS_SCRIPT_EDITOR_0202/tabpECSC_ED/ssubTR_SCRIPT_REF1:SAPLECATT_MAIN:0402/cntlCC_ECSC_EDITOR/shellcont/shell/shellcont[1]/shell/shellcont[1]/shell/shellcont[1]/shell/shellcont[1]/shell").contextMenu
    session.findById("wnd[0]/usr/tabsTS_SCRIPT_EDITOR_0202/tabpECSC_ED/ssubTR_SCRIPT_REF1:SAPLECATT_MAIN:0402/cntlCC_ECSC_EDITOR/shellcont/shell/shellcont[1]/shell/shellcont[1]/shell/shellcont[1]/shell/shellcont[1]/shell").modifyCell 0,"DATA","M_FORMOFADDR"
    session.findById("wnd[0]/usr/tabsTS_SCRIPT_EDITOR_0202/tabpECSC_ED/ssubTR_SCRIPT_REF1:SAPLECATT_MAIN:0402/cntlCC_ECSC_EDITOR/shellcont/shell/shellcont[0]/shell").insertRows "58"
    session.findById("wnd[0]/usr/tabsTS_SCRIPT_EDITOR_0202/tabpECSC_ED/ssubTR_SCRIPT_REF1:SAPLECATT_MAIN:0402/cntlCC_ECSC_EDITOR/shellcont/shell/shellcont[0]/shell").modifyCell 58,"PNAME","M_FORMOFADDR"
    session.findById("wnd[0]/usr/tabsTS_SCRIPT_EDITOR_0202/tabpECSC_ED/ssubTR_SCRIPT_REF1:SAPLECATT_MAIN:0402/cntlCC_ECSC_EDITOR/shellcont/shell/shellcont[0]/shell").modifyCell 58,"PTYP","I"
    session.findById("wnd[0]/usr/tabsTS_SCRIPT_EDITOR_0202/tabpECSC_ED/ssubTR_SCRIPT_REF1:SAPLECATT_MAIN:0402/cntlCC_ECSC_EDITOR/shellcont/shell/shellcont[0]/shell").setCurrentCell 58,"PTYP"
    session.findById("wnd[0]/usr/tabsTS_SCRIPT_EDITOR_0202/tabpECSC_ED/ssubTR_SCRIPT_REF1:SAPLECATT_MAIN:0402/cntlCC_ECSC_EDITOR/shellcont/shell/shellcont[0]/shell").firstVisibleRow = 53
    session.findById("wnd[0]/usr/tabsTS_SCRIPT_EDITOR_0202/tabpECSC_ED/ssubTR_SCRIPT_REF1:SAPLECATT_MAIN:0402/cntlCC_ECSC_EDITOR/shellcont/shell/shellcont[0]/shell").pressEnter
    Edited by: Svetlana Balinova on Jul 21, 2009 3:12 PM
    Edited by: Svetlana Balinova on Jul 21, 2009 3:13 PM

    Hi Svetlana,
    if I have understood correctly, could it be that the following link you could use a bit:
    Referencing a variable in 'session findbyId' command (SAP GUI Scripting)
    Regards,
    ScriptMan

  • SSO E-Sourcing and SAP GUI for HTML

    Hi,
    We are trying to provide integration between SAP E-Sourcing and SAP ECC via the SAP GUI for HTML. From an E-Sourcing project, we should define a link which will link us to the report via SAP GUI for HTML. Some parameters are automatically transferred via the URL so that the report will be prefiltered.
    The problem arises that we cannot create a SSO mechanism between SAP E-Sourcing and SAP GUI for HTML. The only documentation we can find is how to setup this SSO between the Portal and ESO (only included going from the EP to ESO). We need to find a way to do the opposite, i.e. SSO from ESO to SAP / EP.
    Thnx,
    Bram

    Dear Chong,
    I have came across the following information about SAP GUI For HTML
    With the version 7.02 / 7.20 of the NW Application Server
    the SAP GUI for HTML has been completely
    reworked.
    1.The rendering is now based on Unified
    Rendering which is also used by many other
    SAP UI technologies.
    2.Similar Look & Feel as other UI technologies
    3.Better Portal integration
    4.Full Theme support
    5.Unified client requirements
    But have not came across any note which converts the SAP GUI for HTML to SAP GUI for Windows in appearacne. I think the point 2 mentioned about says that in this version the SAP GUI for HTML will have appearnce like the other UI.
    Pls refer the [link|http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/d06db80d-ebf4-2a10-6b99-faa652c69d5c?QuickLink=index&overridelayout=true]
    Hope it helps.
    Regards,
    Samir

  • WebDynpro proxy page with Webdynpro iView and SAP Gui for html iView

    Hello,
    I have a requirement to have a page that has at the top of it a webdynpro for java iView screen with several links that when pressed pop-up various data pulled from the back-end. This part is fine and presents no problem. Beneath this the requirement calls for a SAP Gui for HTML iView to be displayed. Which is no problem either. The problem occurs when one of the links in the java webdynpro application at the top of the screen is pressed it causes the SAP Gui for HTML portion to refresh and come back to the beginning. So for example you first navigate to this screen and you go into the sap gui for html portion and drill into 2 or 3 screens in the sap gui for html transaction. If you then press one of the webdynpro links the sap gui for html (which is a separate iView) refreshes and you are taken back to the initial screen. This only occurs when using a web dynpro proxy page. If I use a standard page the SAP Gi for html does not refresh. Unfortunately there are other things not mentioned here that require us to use the webdynpro proxy page.
    Any help is greatly appreciated,
    Bert

    Use System admin -> System Config and find your system in the PCD (under portal content). Right click and open -> permissions. Find a user or group or role and give it the end user permission. I'd suggest the group Everyone.
    Cheers

  • WDA and SAP-GUI-Integration

    Hello,
    I am testing the integration of an WDA in the SAP-GUI via cl_gui_wdr_viewer and events. it works fine but now i have new challange where i have some problems.
    I the new case, the WDA should run on another Server. I call the WDA with the cl_gui_wdr_viewer->show_url( ), thats works fine but in this case there is no cl_wdr_sapgui_integration-instance in the WD available ?!?
    Does anybody know the condition for the availability of this instance ?!?
    Thx
    Thomas

    Some seperate Installation requirements are need to Install SAP GUI.........
    Windows:
    CPU: Pentium III or equivalent 300 MHz or higher
    Memory: 128 MB or higher
    Monitor: 17" recommended
    Resolution: 1024x768 / 32,000 colors
    MACintosh:
    CPU: G3 or higher
    Memory: 128 MB or higher
    Monitor: 17" recommended
    Resolution: 1024x768
    Kanagaraja L

  • ECATT and SAP GUI

    Hi Friends
    I am new to this forum and would request to help me solving the following problem
    Requirement is as follows.
    Development of screen mapping utility -  which would likely use the eCATT/SAPGUI library.
    Depending on how the eCATT/SAPGUI interface works, probably some infrastructure code to connect, etc.
    How should i go about this.
    Regards
    sunder

    Hello Sunder,
    I think that you should post this question in the SAP GUI.
    Regards
    Gregor

  • Paralell sesions ITS moble and SAP GUI

    Hi All,
    Is it possible to restrict ITS mobile users to access the backend only via ITS?
    Right now they can use ITS mobile screens and at the same time logon to the system via SAP GUI.
    Could you please advise is it possible to block SAP GUI?
    Best regards,
    Adam

    Hi Adam,
    You can try to change the user type to Communication. With this user type, the user cannot logon to system via sapgui but can via http.
    Best regards,
    Yuki

  • SAP GUI Scripting  bug?

    Hi there,
    I developed a custom transaction with only one very simple screen. I disabled the application toolbar in the screen settings (checked "Without Application Toolbar"). But when I start SAP GUI via Scripting API, the application toolbar is always shown. I wonder is this a bug or by design?
    Does anyone know the work around for this? It's a real show stopper for me
    Igor

    Hi Gunnar,
    if You log via myProgram.exe to SAP, then SAP GUI is running in so-called classical design. This also appears to selected design, if the following to be set:
    START -> All programs -> SAP Front End -> SAP GUI Configuration -> Applications -> Add -> myProgram.exe -> Open -> OK-Button
    Regards,
    ScriptMan

  • SAP GUI Scripting API is Disabled in the Server

    Hi,
    I used VB script to upload data into SAP, but in few SAP server scripting is disabled in the server so my codes are not working to upload data.
    Is there any alternative for this other than TX shuttle.
    Is there any HP software to load data to SAP, since i work in hp it will nice to get hp software.
    Thank you so much for your help!
    Reagrds
    Victor

    Hi,
    Follow this linke.
    http://www.synactive.de/download/sap%20gui%20scripting/sap%20gui%20scripting%20security%20settings.pdf
    Thanks
    Yusuf Hamdy

Maybe you are looking for

  • Activate Photoshop 7.0 in Mac OS 10.5.6 ?

    Re: My Headline: Can it be done? This is a holdover between Mac systems 9 and 10. I bought Photoshop 3.0 under Mac System 9. Ditto Photoshop 5.5. I have since bought (and used) Photoshop 7.0 (in the Classic environment, Mac System 9, I suppose). Can

  • SoundMax audio driver did not load after returning from StandBy.

    After my computer returns from StandBy, it shows me this message. "The SoundMax audio driver did not load. You may need to reinstall SoundMAX". I have downloaded and installed the latest driver that was supposed to fix this issue on Windows XP T61. I

  • Recover susp. Account without associated email

    Hey all, I'd like to know how to recover a suspended account without my email associated with the account. Here's what I'm dealing with: -on January 14th I was charged my monthly fee about 9 times. -my account was then suspended and I was told to go

  • Photos do not upload

    I changed the upload folder for photostream (perhaps a mistake) and now photos do not upload. What am I doing wrong?

  • Want to convert 32 bit assembly code to 64 bit assembly

    hi Friends I want to convert 32 bit assembly code to 64 bit. extern "C" long sparc_atomic_add_32 (volatile long* p, long val); static void asm_code() asm(".align 8"); \ asm(".global sparc_atomic_add_32"); \ asm(".type sparc_atomic_add_32, #function")