Reboot while communicating over GPIB

I have a fairly simple program to control an Alessi 6100 scope using GPIB (PCI-GPIB). It seems to work ok, but randomly while its working, the whole computer will just reboot and when it starts up again, I get a message saying "The system recovered from a serious error" and spits out the following codes
BCCode : 1000007e BCP1 : C0000005 BCP2 : F79FB536 BCP3 : F7A56C60
BCP4 : F7A56960 OSVer : 5_1_2600 SP : 1_0 Product : 256_1
Now, I do two different things with the program. One involves moving the scope infrequently (Once every ~8min) and the other moves the scope frequently (Once per second). When moving the scope infrequently, everything's fine, and I can leave it running for over a day without any problems. When I move the scope more often though, it only lasts about 5-10min before it crashes.
I think I'm using the newest drivers (NI-488.2 2.30, VISA 3.1), so I don't think that's the problem. The basic idea of the program works fine on other systems: I've been using an older version of my program to control an Alessi 2500 and move it once every quarter second without any problems. I've just run into trouble with the new scope and different computer.
Just so you know some important history, there was a time on this system where it constantly rebooted (before I could even log into the computer), because nipalk.sys was corrupted, and I've seen other people have this problem too, but I think I fixed that by re-installing the newest drivers. Although if there are remenants left behind when that happens, they could be causing the problem, and I'd love to hear how to completely clean the NI drivers.
Any help would be greatly appreciated. I've attached a NI-Spy log, although it looks pretty normal, so I don't know if it will be any help. (I had to rename it to a .txt file so your forum would accept it, so you'll have to rename it to a .spy file yourself)
Thanks,
Jeff
Attachments:
Capture1.txt ‏971 KB

Ah, as it turns out, the problem is with a capture device I'm using, not any National Instruments device. Sorry to bug you!!

Similar Messages

  • Process Failure when communicating over MODBUS using LabVIEW 2011 and DSC

    I'm currently trying to read from a PLC's holding registers using MODBUS/TCP. I've confirmed that the PLC is updating the values and responding to MODBUS communication correctly using a third party program called Modbus Poll. However, when I try to poll the PLC using LabVIEW's shared variable engine, I am unable to read any values from the same addresses that I'm viewing with Modbus Poll.
    My setup simply consists of a PC connected directly to the PLC over Ethernet, with no router in between. I am using LabVIEW 2011 SP1 with the DSC module.
    I opened the NI Distributed Systems Manager to view the status of all shared variables in the Modbus library that I created and I've noticed that the CommFail bit is permanently set to "true". All other variables with a "read" access mode report "Process Failure". I've tried restarting the process as well as stopping and starting the local variable engine with no success. I've also restarted my computer several times to see if any services were failing, but this does not seem to have fixed the problem.
    I finally resorted to monitoring communications over the network card that I have the PLC plugged into via Ethernet using Wireshark and I've found that while Modbus Poll is communicating with the PLC, many MODBUS and TCP packets are sent and received. However, when solely using LabVIEW or the NI DSM to communicate with the PLC, there does not appear to be any communication over the network card.
    Something that may be worth noting is that I was able to communicate with the PLC and read values from it with the DSM on just one occasion, when I first figured out which addresses I should be reading from. It all stopped working shortly thereafter. Prior to this, "CommFail" was not usually set to "true" with my current configuration. Thinking that it was my firewall, I have since turned my firewall off, but this seems to have had no effect on the problem either.
    Any help on this matter would be appreciated.
    Solved!
    Go to Solution.

    Just a thought but I think the  register addresses used by LabVIEW are one off of the actual register #.  I was using a CRIO as a modbus IO Server and had to shift the register addresses by 1 to get things to work correctly (can;t recall if it was +1 or -1).  This is documented somewhere on ni.com but can;t seem to find it now.  But here is another  link that may help:
    http://zone.ni.com/reference/en-XX/help/371618E-01/lvmve/dsc_modbus_using/
    Dan

  • Receiver SOAP channel error: Communication over HTTPS. Unable to create a socket

    Hi,
    I am getting following error while sending message from PI (7.1) to SalesForce system:
    'SOAP: call failed: java.io.IOException: Communication over HTTPS. Unable to create a socket'
    Scenario: Sending Customer data from SAP via Async proxy to PI which is sent further to SalesForce system via SOAP webservice call.
    When I am trying to Post data to the same webservice via SOAP UI it is working fine and data is getting updated in SalesForce system.
    XPI inspector logs for the channel suggest the following:
    client [103965] RequestImpl.initSslAttributes(): Initially sslAttributes = null
    client [103965] RequestImpl.initSslAttributes(): Cannot find SSL headers in the request.
    client [103965] RequestImpl.initSslAttributes(): No SSL attributes: not found in headers and not searched in FCA, because connection.isSecure() = false; sslAttributes = null
    I have checked the following SAP Note and requested for updation of SSL icm parameters
    891877 - Message-specific configuration of HTTP-Security
    I checked the following discussions:
    http://scn.sap.com/message/8910518#8910518
    http://scn.sap.com/message/6244674#6244674
    http://scn.sap.com/thread/2100000
    http://scn.sap.com/thread/1632114
    which are suggesting a different approach. Kindly suggest a way forward.
    Thanks,
    Vishwajeet

    This is related network issue.
    Did you do telnet in pi server with target system ip and port?
    If you use https then you need to install certificates.
    Check below threads
    http://scn.sap.com/thread/190299
    Unable to create socket error

  • An error occurred while communicating with the BI server.

    Hi Expert,
    A error occured when I finish updating the new patch of the Addon, When I finish updating it, it works okay , but when I reboot the system, it disconnet our server and give the following exception :
    An error occurred while communicating with the BI server.
    System exception thrown while marshaling .NET type System.Byte[] to RFCTYPE_BYTE.
    Are there anyone met such issues?
    Please help
    Len

    Hi,
    Are you getting this error while connecting to the Backend through BEx Tools.
    Is that system available or System down while connecting.
    Rgds,
    Murali

  • How to retain the button over state while scrolling over a Pop-up Menu

    Are there updated instruction for Fireworks 8?
    http://kb.adobe.com/selfservice/viewContent.do?externalId=tn_15926&sliceId=1

    I just wouldn't use those menus at all - there are much
    better ways. Have
    you considered them?
    Check the uberlink and MacFly tutorials at PVII -
    http://www.projectseven.com/
    and the Navbar tutorial/articles at Thierry's place
    http://tjkdesign.com/articles/dropdown/
    Or this one (more recent article):
    http://tjkdesign.com/articles/Pure_CSS_Dropdown_Menus.asp
    Or to get it done fast, go here -
    http://www.projectseven.com/tutorials/navigation/auto_hide/index.htm
    Murray --- ICQ 71997575
    Adobe Community Expert
    (If you *MUST* email me, don't LAUGH when you do so!)
    ==================
    http://www.dreamweavermx-templates.com
    - Template Triage!
    http://www.projectseven.com/go
    - DW FAQs, Tutorials & Resources
    http://www.dwfaq.com - DW FAQs,
    Tutorials & Resources
    http://www.macromedia.com/support/search/
    - Macromedia (MM) Technotes
    ==================
    "turpya" <[email protected]> wrote in
    message
    news:f2ilfs$7gr$[email protected]..
    > Hi,
    >
    > I am trying to work out how to retain button over state
    while scrolling
    > over a
    > pop-up menu. By default the button changes back to mouse
    out state, when
    > scrolling over menu items for that button.
    >
    > I have tried to follow the advice in the below technote
    (see link below),
    > but
    > it seems the instructions are incorrect.
    >
    > I am using Fireworks 8 - it appears the instructions are
    for a prior
    > version.
    > I cannot find function fwLoadMenus() mentioned in Step 3
    (number 6.).
    >
    > Has anyone accomplished this in Fireworks 8, that could
    provide me with
    > instructions?
    >
    > Thanks in advance,
    >
    > turpya.
    >
    >
    http://www.adobe.com/cfusion/knowledgebase/index.cfm?id=tn_15926
    >

  • Utility to receive 'scope hardcopy over GPIB?

    We're using a Tek 11801C, and it does not have a floppy drive.
    I'd like to capture the hardcopy (Bitmap Dump) onto my PC over GPIB. If set the instrument to Talk Only and press Hardcopy, bits start flying out over the bus.
    If I open up NI 488.2 Communicator and click Read, I can catch a few bytes
    But what I'd really like to do is have some sort of utility where I can set it to "listen" for a file transfer, and then hit Hardcopy on the 'scope and have it capture it to a file.
    We don't use LabVIEW.
    Does such a utility exist? Thanks!

    Hello
    Thera are 2 posts that can lead you to a solution:ç
    http://exchange.ni.com/servlet/ProcessRequest?RHIVEID=101&RPAGEID=135&HOID=506500000008000000A1F50000&USEARCHCONTEXT_CATEGORY_0=_26_%24_13_&USEARCHCONTEXT_CATEGORY_S=0&UCATEGORY_0=_26_%24_13_&UCATEGORY_S=0
    and
    http://exchange.ni.com/servlet/ProcessRequest?RHIVEID=101&RPAGEID=135&HOID=50650000000800000074F50000&USEARCHCONTEXT_CATEGORY_0=_49_%24_6_&USEARCHCONTEXT_CATEGORY_S=0&UCATEGORY_0=_49_%24_6_&UCATEGORY_S=0
    Hope it helps
    Alipio
    "Qod natura non dat, Salmantica non praestat"

  • Utility to send text file over GPIB, one line at a time?

    We are developing instrumentation that receives data and commmands over GPIB as plain text, and returns them as well. I'd like to create GPIB "batch" files and send them over the bus, one line at a time, so I can debug the instruments' behavior. I'd also like to be able to read back responses, one line at a time.
    Is there such a utility? I've got our programmer working on something like this, but I'd hate to have him re-invent an existing wheel.
    Thanks!

    Apart from NI-SPY, I have not heard of such a utility. This may be simple to implement using proper termination. If the instrument is capable of sending line feeds or carriage return, you should be able to easily create a document. Also, using IBWRTF, you could write the ASCII file (containing the termination characters) to the bus. Depending on how you have your timeouts specified, this may be ideal.
    Alternately, if you read a static amount of data, you could IBRD chunks of data. the result may need editing for broken words at the end of a line but would achieve such a result.
    Ryan Mosley
    National Instruments, Applications Engineer
    http://www.ni.com/exchange

  • Server error while communicating to BI server

    Hi,
    There is a run time error while executing the Query in Bex Analyser while the same query is working fine in Portal..
    *Cant paste the image here, but the error states -:
    AN ERROR OCCURED WHILE COMMUNICATING WITH THE BI SERVER
    As a result of this error, the system has been disconnected from the BI server.
    Detailed Description:
    System exception thrown while marshaling RFCTYPE_CHAR to .NET type*
    I really dont know much about this as I am Basis Guy! Please suggest some actions from the Basis Point of view.
    Regards!
    Deep!

    HI,
    Check if you have latest front end patch for your GUI and also make sure the .NET framework 2.0 is installed. This is needed for SAP BI7 BEx analyzer.
    Also, take a look at this note 1013202.
    Hope it helps.
    Thanks,
    KR

  • Error occured while communicating with web server

    In Netweaver if you receive this error  " error occured while communicating with web server "
    check your script logic file if you have mande any change to dimension
    names
    Vinoo

    Hi,
    validate below note
    Note 1330145 - an error occured while communicating with the web server
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/b161a590-0201-0010-5590-91fa5076a914
    regards
    nag

  • My iPhone 4 rebooting while hooked up to charge after fall.

    My iPhone 4 recetly fell from pocket to my foot and turned off right away, now it's only rebooting while connected to a charging source; but only continuous reboots. We can't connect to restore it to iTunes because the home button doesn't work as well. I've tried everything the site suggests to do, but absolutely nothing works.

    I'm afraid you'll have to get it serviced:
    You can do that by visiting an Authorized Apple Service Provider or an Apple Store next to your place.
    Or contact Apple Support:
    iPhone - Contact Support - Apple Support

  • Error on timesheet submission "An error occurred while communicating with the server.

    Hello, we have many users who are encountering errors submitting timesheets following our migration to Project Server 2013 (SP1 April 2014 CU). The error is:
    An error occurred while communicating with the server. Check connectivity with your administrator to determine whether further action is necessary.
    This follows the specific timesheet, if I open a delegate session on my machine, I can reproduce the error. However, simply deleting and recreating the timesheet has resolved it for many users, at least until the next timesheet submission.
    Has anyone seen this sort of widespread behavior and have a solution beyond deleting and recreating the given timesheet?
    Thanks!

    Hello Joncantrell
    I just ran into issue and found a way to resolve, though it may not be the best.  I think it is a bug, but here is how I fixed it.
    1) Delegating as the user
    2) Deleted the timesheet
    3)  Going line by line, I check each task that had a status of "Not Submitted" and "Send Progress for Select Task".
    4) The error came up only for one task.
    5) Open that schedule, remove resource from task, saved and published.
    6) Deleted and recreated timesheet
    7) Submitted timesheet and processed normally.
    I hope this helps
    Cheers!
    Michael Wharton, MVP, MBA, PMP, MCT, MCTS, MCSD, MCSE+I, MCDBA
    Website http://www.WhartonComputer.com
    Blog http://MyProjectExpert.com contains my field notes and SQL queries

  • MAX don't release LAN connction while communicating with Agilent 86122A

    Dear guys,
    Yesterday I met a communication issue while talking to Agilent 86122A via LAN.
    It showed I cannot run MAX before launching LabVIEW; otherwise I'd have trouble in send commands in LabVIEW.
    I doubt if MAX MAX don't release LAN connection while communicating with Agilent 86122A?
    Please advise,thanks.
    I debugged as below:
    1, Ping the IP of Agilent 86122A shows internet is OK.
    2, I restarted the instrument, LabVIEW reported the same error code.
    3, I restarted PC, launched LabVIEW first and run the code (*IDN?), everything is OK!!!
    4, Again, I send *IDN? With MAX, and it seemed to be OK.
    5, hit x to close MAX and then run the same and simple code (*IDN?) in LabVIEW, but it reports error code -1073807346.

    Caglar,
    The documents you mention ahould include the proper prcedure for using this hardware in LabVIEW. Here are my recommendations:
    The version of NI-VISA  you mentioned is not valid. The most recent version is 4.6.2. I would recommend ugrading if you do not have this version. After the upgrade,ensure that tulip is enabled as well as the other settings and see if this helps.
    When talking about the instrument, the biggest concern that usually is relevant with 488.1 is that it will not respond to *IDN?. In your case, it looks like it does, and should work as 488.2 is backwards compatible. It seems to me, the issue is still with the 82357A, and we have not yet reached the voltmeter.
    In order for NI-VISA to work with your device, NI-VISA must be the primary visa driver.
    Hope this helps, let us know how the upgrade turns out. If you continue to have issues, take some screenshots of the preferences in MAX and upload them on the forum.
    Regards,
    Peter Flores
    Applications Engineer

  • "error occurred while communicating with scanner" mac os x 10.8.2 with new hp 6700.

    device will not scan to computer.  returns "error occurred while communicating with scanner".  this error returns from the print/scan settings, from image capture and from the HP scan utility.  the printer will copy so the scanner will function to some extent.  it is brand new. on a wireless network.  prints fine
    OS is fully up-to-date, drivers are current, downloaded from HP and installed rather than using CD.  device has been unplugged from wall, computer restarted, printers cleared and reinstalled.
    any other ideas?
    some more info...
    if a sheet is placed in the scan feeder, the scanner illuminates and makes a ping sound.
    firewalls are off
    router has UPnP on
    old printer, an hp6500, worked fine with identical setup
    and a further note as I try to solve this...
    the webscan function works from the printer web server
    HP Utility does not have a Scan section.  HP Utility Applications has Scan 3.  this does not work

    Hi BetterL8,
    I understand your frustration. The software you are using was designed for the older operating system not for Mavericks. There has not been software released for the c310 that is compatible with Mavericks therefore, you will be using the Apples Print and Scan not the HP Scan. Because you have this old software still on the computer, I recommend you uninstall it and download the Apple Software Update. Follow the instructions below:
    Scrub
    Open the Applications folder > HP or Hewlett Packard folder > HP Uninstaller
    Click continue, click on one of the printers in the list.
    Hold down Control, Option and Command
    While holding the three buttons down, Click uninstall.
    Reset Printing System
    Click the Apple icon ( ), and then click System Preferences.
    In the Hardware section, click Print & Fax/Scan. The Print & Fax/Scan  dialog box opens.
    Right-click (or Ctrl +click) in the left panel, and then click  Reset printing system…
    Click OK to confirm the reset.
    Type the correct Name and Password.
    Click  OK to reset the printing system. The Print & Fax dialog box shows no printer selected
    Note: This will remove all printers in the print and Fax/Scan, any printer removed can be re-added later by clicking the plus (+) symbol
    Repair Disk Permissions (this is good measure to ensure non of your permissions differ)
    On the Dock, click  Applications, and then click  Utilities.
    Double-click  Disk Utility.
    Highlight your hard drive/partition on the left (by default this is "Macintosh HD").
    Click the Repair Disk Permissions button at the bottom of the window.
    Once the repair is complete, restart the computer.
    Restart the computer.
    Check for apple updates
    Connect the USB cable if it is not already connected
    Click on the Apple icon
    Select Software Updates.
    Restart the computer.
    Leave the printer on and unplug the power cable, reconnect after 1 minute.
    See next post for further instructions....
    Please click the Thumbs up icon below to thank me for responding.
    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
    Please click “Accept as Solution” if you feel my post solved your issue, it will help others find the solution.
    Sunshyn2005 - I work on behalf of HP

  • Error encountered while communicating with primary IP-address

    Hi
    I have recently deployed my first Exchange Server. This is an Exchange Server 2013 Standard and I set up everything using this document on Technet for installation: http://technet.microsoft.com/en-us/library/bb124778(v=exchg.150).aspx
    For post-installation I used this document on Technet: http://technet.microsoft.com/en-us/library/bb124397(v=exchg.150).aspx
    I have setup access to port 25, 587, 143, 993, 110, 995, 80, 443 in my routers SPI-firewall and created DNAT rules for each of these ports as well. I can send mail without any issues, but I cannot receive. Reverse DNS is working both internally and externally.
    I can telnet to port 25 on my external IP and external domain which is exchange.mydomain.tld
    My Exchange-server is running inside a Gen1 Hyper-V virtual machine on a Windows Server 2012 R2.
    My Exchange Server has the following resources:
    OS: Windows Server 2012 R2
    CPU: 2 cores of AMD FX-6120 3.30GHz
    RAM: 3584MB
    HDD1: IDE 80GB VHDX - is currently used for all system files and for Exchange.
    HDD2: SCSI 127GB VHDX - will be used for Exchange DB and logs when everything is working.
    When sending mail from any internal or external e-mail address to an internal e-mail address I get the following error in Exchange Queue Viewer:
    "451 4.4.0 Error encountered while communicating with primary target IP address:"421 4.2.1 Unable to connect." Attempted failover to alternate host, but that did not succeed. Either there are no alternate hosts, or delivery failed to all alternate
    hosts. The Last"
    How can I solve this issue? If you need any more information please let me know and I will see if I can find it.

    Hi I have now tried to send mail to an internal address using telnet. This returned the following value:
    250 2.6.0 <[email protected]> [InternalId=1971389988866] Queued mail for delivery
    Next I tried to send to an external mail by using telnet and it returned this result when adding the reciepient:
    550 5.7.1 Unable to relay
    This is the output of the Test-Servicehealth cmdlet:
    Role                    : Mailbox Server Role
    RequiredServicesRunning : True
    ServicesRunning         : {IISAdmin, MSExchangeADTopology, MSExchangeDelivery, MSExchangeIS, MSExchangeMailboxAssistant
                              s, MSExchangeRepl, MSExchangeRPC, MSExchangeServiceHost, MSExchangeSubmission, MSExchangeThro
                              ttling, MSExchangeTransportLogSearch, W3Svc, WinRM}
    ServicesNotRunning      : {}
    Role                    : Client Access Server Role
    RequiredServicesRunning : True
    ServicesRunning         : {IISAdmin, MSExchangeADTopology, MSExchangeMailboxReplication, MSExchangeRPC, MSExchangeServi
                              ceHost, W3Svc, WinRM}
    ServicesNotRunning      : {}
    Role                    : Unified Messaging Server Role
    RequiredServicesRunning : True
    ServicesRunning         : {IISAdmin, MSExchangeADTopology, MSExchangeServiceHost, MSExchangeUM, W3Svc, WinRM}
    ServicesNotRunning      : {}
    Role                    : Hub Transport Server Role
    RequiredServicesRunning : True
    ServicesRunning         : {IISAdmin, MSExchangeADTopology, MSExchangeEdgeSync, MSExchangeServiceHost, MSExchangeTranspo
                              rt, MSExchangeTransportLogSearch, W3Svc, WinRM}
    ServicesNotRunning      : {}
    Can we use this information to find a possible source for my issues?

  • Conversion Error: I/O error while communicating with native process

    Hi,
    I am trying to use Oracle Outside In Technology Image Export for conversion of images. I am trying to run the example ExportTest that comes with the downloaded SDK.
    I get the below error while running the ExportTest example.
    Conversion Error: I/O error while communicating with native process .
    Am I missing any settings?
    Please guide to the right forum if this is not the one for posting queries on Oracle Outside In Technology Image Export.
    Thank you.

    Hi Revanth,
    I am using Image Export 8.3.7 and I am trying to run the java class "ExportTest" that is in the location sdk\samplecode\ExJava\Examples\ExportTest\src of the download.
    My input folder has one jpg - puzzle.jpg (this is just a simple jpg), I am trying to convert it to TIFF. ExportTest.java uses the classes in Export.jar . Export.jar is located in the sdk\samplecode\ExJava\Examples\ExportTest . You can see source files of the Export.jar at location sdk\samplecode\ExJava\Java API\src of the download. I am running the 'ExportTest' by providing the arguments (input folder, output folder and ix.cfg - this file comes with the download). So now when I run this class I was getting the error I mentioned in this post. Inorder to find more details about the error I modified the 'Export.java' (at sdk\samplecode\ExJava\Java API\src\com\outsideinsdk) just to printStackTrace when the exception occurs and rebuilt the 'Export.jar' and ran the 'ExportTest.java'.
    And below is the stack trace that I got :
    java.io.IOException: CreateProcess: nullexporter.exe "inputpath_u=AGkAbgBwAHUAdA
    BcAHAAdQB6AHoAbABlAC4ASgBQAEc=" "outputpath_u=AG8AdQBwAHUAdABcAHAAdQB6AHoAbABlAC
    4ASgBQAEcALgBUAEkARgBG" "outputid=FI_TIFF" "fallbackformat=FI_TEXT" "tiffcolorsp
    ace=24BitRGB" "preferoitrendering=false" "tiffcompression=Packbits" "mapbuffersi
    ze=8192" "defaultprintfontheight=20" "graphicwidthlimit=0" "reordermethod=off" "
    unmappablechar=0x002A" "timezone=0" "graphicheightlimit=0" "defaultmarginleft=14
    40" "ssshowheadings=false" "quickthumbnail=false" "graphicoutputdpi=0" "ssdirect
    ion=AcrossandDown" "defaultmarginbottom=1440" "ssshowgridlines=false" "dbshowhea
    dings=false" "readbuffersize=2" "whattoexport=all" "graphicsizelimit=0" "imagewa
    termarkopacity=0" "blue=-1" "handlenewfileinfo=no" "outputid=FI_TIFF" "lzwcompre
    ssion=enabled" "usedocpagesettings=true" "defaultmarginright=1440" "numberofstat
    callbacks=0" "dbfittopage=NoScaling" "tempbuffersize=2048" "pdffilterreorderbidi
    =no" "imagecropping=nocropping" "defaultmargintop=1440" "documentmemorymode=larg
    e" "m?
    at java.lang.Win32Process.create(Native Method)
    at java.lang.Win32Process.<init>(Win32Process.java:66)
    at java.lang.Runtime.execInternal(Native Method)
    at java.lang.Runtime.exec(Runtime.java:566)
    at java.lang.Runtime.exec(Runtime.java:491)
    at java.lang.Runtime.exec(Runtime.java:457)
    at com.outsideinsdk.Export.convert(Export.java:262)
    at com.outsideinsdk.ExportTest.convert(ExportTest.java:142)
    at com.outsideinsdk.ExportTest.main(ExportTest.java:214)
    hope this helps to find the problem.
    Thank you

Maybe you are looking for

  • Help with resultset and looping thru a sql filed

    Hi, I have a SQL statement which connects two tables with accounting number, the table2 have multiple rows for one accounting number in table1. So I did if else condition in accounting number in resultset as following: List<AccRecord> retval = new Ar

  • Strange Chars after modify reports.sh NLS_LANG

    I had a problem when I modify NLS_LANG in reports.sh in linux. If i put NLS_LANG=PORTUGUESE_PORTUGAL.WE8MSWIN1252 my reports comes with strange some like greek characters. My database charset is WE8MSWIN1252. My database v$NLS_PARAMETERS are: NLS_DAT

  • Applescript to automate the laboreous matching and moving jpg/CR2 files

    Hi I used to use MS Basic (at school) and was (really) good at Hypertalk but have done no scripting for years (since they killed Hypercard) I am a photographer (as a hobby) and will take 1000-2000 photos on a weekend. I shoot JPG & CR2. The JPG are m

  • What am I doing wrong?  Can't get images to open correctly in CS5.

    I've been using Lightroom 3 for a  while and decided to take the plunge and integrate CS5 into my  workflow.  I'm really new to CS5, so this is probably a stupid  question.  When I try to edit a photo in CS5, all I see is a black  screen.  I can see

  • My Satellite A60 getting "crazy"

    Hello everyone After I installed Windows XP pro on the same partition the default Windows was intalled in, My Satellite A60 started to shut down suddenly after a certain time, the screen also switches to its minimum luminance so I can't see anything