Reg Generic FM Delta

Hi Friends,
                 For generic extraction I created the function module and its working fine. My requiremnet is how to set up delta for this function module ?
Actually in this FM  I had 3 keyfields. But in RSO2 generic delta only one field is possible and i think I can not use for FM time stamp and calender day and .
In this case how i set the delta for my FM for these 3 fields ?
Can you please suggest any one and ur answers are highly appreciable and
points will be award.
Thanks & Regards,
Govind.

You could do the following:
Create an extra table with the keys. When you pass data to the BW store the key in this table and make sure that you don't pass any key twice.
But I would recommend to do a full upload and do the delta with a DataStore-Object (ODS). You need to select all data anyway so you won't save a lot of performance if you do it in the source system.
Best regards
   Dirk

Similar Messages

  • Standard and generic COPA delta

    Hello
    I dont understand why many people say standard copa delta  , generic copa delta.
    COPA is a generated application and delta should be generic.
    What do you mean when you are talking (many posts in this forum) about standard copa delta?
    Thanks

    Hi,
    Copa extraction is generated application based on the operating concren configured in R/3 system. and same applied to delta process.
    R/3 table TKEBWTS contains information about the COPA load requests that have been posted into BW.  time stamp entries in this table can be maintained to reintialize the delta. this may be the reason some may call in generic or standard delta.
    Dev

  • Doubt Reg Generic Delta "Safety Interval" Setting

    Hi Experts,
    I have a doubt regarding Setting "Safety Interval Upper Limit" and Lower limit in RSO2 for generic delta.
    What does this setting imply?
    If I do setting for calender day say both 1 then wht will be difference between delta before setting amd after setting?
    Plz explain in terms other tham help provided...
    Points will be awarded to say thanks..
    Thanks in advance,
    Sorabh

    Hi Sorabh,
    Here some SAP informations:
    Safety Interval Upper Limit of Delta Selection
    This field is used by DataSources that determine their delta generically using a repetitively-increasing field in the extract structure. The field contains the discrepancy between the current maximum when the delta or delta init extraction took place and the data that has actually been read. Leaving the value blank increases the risk that the system could not extract records arising during extraction. Example: A time stamp is used to determine the delta. The time stamp that was last read is 12:00:00. The next delta extraction begins at 12:30:00. In this case, the selection interval is 12:00:00 to 12:30:00. At the end of extraction, the pointer is set to 12:30:00.  A record - for example, a document- is created at 12:25 but not saved until 12:35. It is not contained in the extracted data but, because of its time stamp, is not extracted the next time either.
    For this reason, the safety margin between read and transferred data must always be larger than the maximum length of time that it takes to create a record for this DataSource (with a time stamp delta), or it must display an interval that is sufficiently large (for determining delta using a serial number).
    Safety Interval Lower Limit
    This field contains the value taken from the highest value of the previous delta extraction to determine the lowest value of the time stamp for the next delta extraction. For example: A time stamp is used to determine a delta. The extracted data is master data: The system only transfers after-images that overwrite the status in the BW. Therefore, a record can be extracted into the BW for such data without any problems.
    Taking this into account, the current time stamp can always be used as the upper limit when extracting: The lower limit of the next extraction is not seamlessly joined to the upper limit of the last extraction. Instead, its value is the same as this upper limit minus a safety margin. This safety margin needs to be big enough to contain all values in the extraction which already had a time stamp when the last extraction was carried out but which were not read. Not surprisingly, records can be transferred twice. However, for the reasons above, this is unavoidable.
    Extracted Data Delta Type
    The system uses the delta type to determine how extracted data is to be interpreted in BW, and into which data targets it can be posted.
    A distinction is made between the following:
    1. Additive delta
    The key figures for extracted data are added up in BW. DataSources with this delta type can supply data to ODS objects and InfoCubes.
    2. New status for changed records
    Each record to be loaded delivers the new status for the key figures and characteristics. DataSources with this delta type can write to ODS objects or master data tables.
    Check also examples in "How to... Create Generic Delta" under www.service.sap.com/bi.
    Ciao.
    Riccardo.

  • Generic Extraction Delta Loads

    Hi Experts,
    I am facing problem is I want to extract the data in Generic Extraction in View, Suppose my requirement is I want to delta loads every 1 hour per day, how can i do, Generic Extraction possible are not delta records.
    Note:- LO Extraction is possible like we have update mode we can scheduled hours in everyday, But Generice Extraction possible are not.
    Please provide me solutions ASAP.
    Thanks in Advance......
    Regards,
    Bharathi.

    There are various delta method
    1.calday.
    2.time stamp.
    3.Numeric pointer.
    For youe requirement Time stamp will work.
    Please check weather you have any field related to time.
    Thanks,
    Saveen kumar

  • Reg Generic Extraction

    Hi Gurus,
    Can any one explain me about generic extraction like,
    1) when we go for Generic extraction
    2) what is the business scenario
    3) generic delta
    Please explain me with step by step by choosing some data fields as example for this. One request, plz don't send sap help file as i have it. If any one have screen shots for this plz send me.
    Thanks in advance.
    Regards
    K.M.Reddy

    hi,
      we go for generic extraxctor when standard cube or datasource do not suite the
    requirement.
    for eg in satandard sd datasource donot have the field we require  then we
    go for generic datasource.
    if standard datasource do not have shipping point field in datasource then we
    can either append the structure or go for generic datasource.
    for generic delta refer link.
    http://help.sap.com/saphelp_nw04s/helpdata/en/37/4f3ca8b672a34082ab3085d3c22145/frameset.htm
    regards
    pls assign points if helpful.

  • BW GENERIC EXTRACTION DELTA PROBLEM

    I have a problem for extracting delta from R/3 to BW.
    Init data is loaded from R/3 to BW system for ZST_ORDER datasource.
    Repair full request and selection parameter is created on date August 1st 2007 to August15th 2007.
    During the delta extraction - A lot of records around 500,000 records are getting extracting from R/3 to BW.
    R/3 side - There is only 5 entries available in AUFK table.
    It should extract delta only less than 35 entries.
    ZST_ORDER is generic datasource . Delta captured field is DATUM -New status changed record value 2.
    Advance Thx for your help. The code looks like
    FUNCTION ZST_ORDER.
    ""Local Interface:
    *" IMPORTING
    *" REFERENCE(I_REQUNR) TYPE SRSC_S_IF_SIMPLE-REQUNR
    *" REFERENCE(I_DSOURCE) TYPE SRSC_S_IF_SIMPLE-DSOURCE OPTIONAL
    *" REFERENCE(I_MAXSIZE) TYPE SRSC_S_IF_SIMPLE-MAXSIZE DEFAULT 1000
    *" REFERENCE(I_INITFLAG) TYPE SRSC_S_IF_SIMPLE-INITFLAG OPTIONAL
    *" REFERENCE(I_READ_ONLY) TYPE SRSC_S_IF_SIMPLE-READONLY OPTIONAL
    *" TABLES
    *" I_T_SELECT TYPE SRSC_S_IF_SIMPLE-T_SELECT OPTIONAL
    *" I_T_FIELDS TYPE SRSC_S_IF_SIMPLE-T_FIELDS OPTIONAL
    *" E_T_DATA STRUCTURE ZST_ORDEROPTIONAL
    *" EXCEPTIONS
    *" NO_MORE_DATA
    *" ERROR_PASSED_TO_MESS_HANDLER
    TABLES: AUFK, "Order master data
    TJ02T, "System status texts
    TJ30T, "Texts for user status
    JSTO. "Status object information
    DATA DECLARATION
    DATA: L_DATE TYPE DATS,
    L_STATUS TYPE J_STATUS,
    L_LINES TYPE SY-TABIX,
    L_CHANGED(1) TYPE C.
    Auxiliary Selection criteria structure
    DATA: L_S_SELECT TYPE SRSC_S_SELECT.
    Another data objects
    Service Order Data
    DATA: BEGIN OF LT_AUFK OCCURS 0,
    AUFNR LIKE AUFK-AUFNR,
    AUART LIKE AUFK-AUART,
    ERDAT LIKE AUFK-ERDAT,
    AEDAT LIKE AUFK-AEDAT,
    STDAT LIKE AUFK-STDAT,
    AEZEIT LIKE AUFK-AEZEIT,
    ERFZEIT LIKE AUFK-ERFZEIT,
    IDAT1 LIKE AUFK-IDAT1,
    IDAT2 LIKE AUFK-IDAT2,
    IDAT3 LIKE AUFK-IDAT3,
    LOEKZ LIKE AUFK-LOEKZ,
    OBJNR LIKE AUFK-OBJNR,
    END OF LT_AUFK.
    Individual Object Status
    DATA: BEGIN OF LT_JEST OCCURS 0,
    OBJNR LIKE JEST-OBJNR,
    STAT LIKE JEST-STAT,
    INACT LIKE JEST-INACT,
    CHGNR LIKE JEST-CHGNR,
    END OF LT_JEST.
    ***Change Documents for System/User Statuses (Table JEST)
    DATA: BEGIN OF LT_JCDS OCCURS 0,
    OBJNR LIKE JCDS-OBJNR,
    STAT LIKE JCDS-STAT,
    CHGNR LIKE JCDS-CHGNR,
    USNAM LIKE JCDS-USNAM,
    UDATE LIKE JCDS-UDATE,
    UTIME LIKE JCDS-UTIME,
    INACT LIKE JCDS-INACT,
    CHIND LIKE JCDS-CHIND,
    END OF LT_JCDS.
    DATA: BEGIN OF LT_JSTO OCCURS 0,
    OBJNR LIKE JSTO-OBJNR,
    STSMA LIKE JSTO-STSMA,
    END OF LT_JSTO.
    STATIC FIELDS
    STATICS: S_S_IF TYPE SRSC_S_IF_SIMPLE,
    counter
    S_COUNTER_DATAPAKID LIKE SY-TABIX,
    cursor
    S_CURSOR TYPE CURSOR.
    User-defined Ranges
    RANGES: L_R_AUFNR FOR AUFK-AUFNR ,
    L_R_ERDAT FOR AUFK-ERDAT.
    Initialization mode (first call by SAPI) or data transfer mode
    (following calls) ?
    IF I_INITFLAG = SBIWA_C_FLAG_ON.
    Check DataSource validity
    CASE I_DSOURCE.
    WHEN 'ZST_ORDER '.
    WHEN OTHERS.
    RAISE ERROR_PASSED_TO_MESS_HANDLER.
    ENDCASE.
    Copy selection criteria for future extractor calls (fetch-calls)
    APPEND LINES OF I_T_SELECT TO S_S_IF-T_SELECT.
    Fill parameter buffer for data extraction calls
    S_S_IF-REQUNR = I_REQUNR.
    S_S_IF-DSOURCE = I_DSOURCE.
    S_S_IF-MAXSIZE = I_MAXSIZE.
    S_S_IF-INITFLAG = I_INITFLAG.
    APPEND LINES OF I_T_FIELDS TO S_S_IF-T_FIELDS.
    ELSE.
    First data package -> OPEN CURSOR
    IF S_COUNTER_DATAPAKID = 0.
    LOOP AT S_S_IF-T_SELECT INTO L_S_SELECT
    WHERE FIELDNM = 'AUFNR'.
    MOVE-CORRESPONDING L_S_SELECT TO L_R_AUFNR.
    APPEND L_R_AUFNR.
    ENDLOOP.
    LOOP AT S_S_IF-T_SELECT INTO L_S_SELECT
    WHERE FIELDNM = 'ERDAT'.
    MOVE-CORRESPONDING L_S_SELECT TO L_R_ERDAT.
    APPEND L_R_ERDAT.
    ENDLOOP.
    LOOP AT S_S_IF-T_SELECT INTO L_S_SELECT
    WHERE FIELDNM = 'DATUM'.
    L_DATE = L_S_SELECT-LOW.
    ENDLOOP.
    OPEN CURSOR WITH HOLD S_CURSOR FOR
    SELECT AUFNR AUART ERDAT
    AEDAT OBJNR AEZEIT
    STDAT ERFZEIT IDAT1
    IDAT2 IDAT3 LOEKZ
    FROM AUFK
    WHERE AUFNR IN L_R_AUFNR AND
    ERDAT IN L_R_ERDAT.
    ENDIF.
    Fetch records into interface table LT_AUFK
    FETCH NEXT CURSOR S_CURSOR
    APPENDING CORRESPONDING FIELDS OF TABLE LT_AUFK
    PACKAGE SIZE S_S_IF-MAXSIZE.
    IF SY-SUBRC <> 0.
    CLOSE CURSOR S_CURSOR.
    RAISE NO_MORE_DATA.
    ENDIF.
    Determining the number of lines of the table LT_AUFK .
    L_LINES = LINES( LT_AUFK ).
    IF L_LINES IS NOT INITIAL.
    Sort the internal table LT_AUFK
    SORT LT_AUFK BY OBJNR ASCENDING.
    Selecting the records from JCDS depending upon the entries in LT_AUFK.
    SELECT OBJNR STAT CHGNR USNAM
    UDATE UTIME INACT CHIND
    INTO TABLE LT_JCDS
    FROM JCDS
    FOR ALL ENTRIES IN LT_AUFK
    WHERE OBJNR EQ LT_AUFK-OBJNR
    AND ( CHGNR EQ '001'
    OR UDATE >= L_DATE ).
    Sort the internal table lt_jcds.
    SORT LT_JCDS BY OBJNR STAT CHGNR ASCENDING.
    Select records from table JEST depending upon the entries in LT_AUFK.
    SELECT OBJNR STAT INACT CHGNR
    INTO TABLE LT_JEST
    FROM JEST
    FOR ALL ENTRIES IN LT_AUFK
    WHERE OBJNR = LT_AUFK-OBJNR.
    SELECT OBJNR STSMA
    INTO TABLE LT_JSTO
    FROM JSTO
    FOR ALL ENTRIES IN LT_AUFK
    WHERE OBJNR = LT_AUFK-OBJNR.
    SORT LT_JSTO BY OBJNR.
    ENDIF.
    LOOP AT LT_JEST.
    CLEAR: LT_AUFK,
    l_changed.
    CLEAR L_CHANGED.
    CLEAR LT_JSTO.
    READ TABLE LT_JSTO WITH KEY OBJNR = LT_JEST-OBJNR BINARY SEARCH.
    IF SY-SUBRC EQ 0.
    E_T_DATA-STSMA = LT_JSTO-STSMA.
    ENDIF.
    *End**
    Read the data from LT_AUFK.
    READ TABLE LT_AUFK WITH KEY OBJNR = LT_JEST-OBJNR BINARY SEARCH.
    E_T_DATA-AUFNR = LT_AUFK-AUFNR.
    E_T_DATA-AUART = LT_AUFK-AUART.
    E_T_DATA-ERDAT = LT_AUFK-ERDAT.
    E_T_DATA-AEDAT = LT_AUFK-AEDAT.
    E_T_DATA-AEZEIT = LT_AUFK-AEZEIT.
    E_T_DATA-ERFZEIT = LT_AUFK-ERFZEIT.
    E_T_DATA-IDAT1 = LT_AUFK-IDAT1.
    E_T_DATA-IDAT2 = LT_AUFK-IDAT2.
    E_T_DATA-IDAT3 = LT_AUFK-IDAT3.
    E_T_DATA-LOEKZ = LT_AUFK-LOEKZ.
    E_T_DATA-INACT = LT_JEST-INACT.
    E_T_DATA-CHGNR = LT_JCDS-CHGNR.
    e_t_data-datum = lt_aufk-erdat.
    READ TABLE LT_JCDS WITH KEY OBJNR = LT_JEST-OBJNR
    STAT = LT_JEST-STAT
    CHGNR = '001'
    BINARY SEARCH.
    IF SY-SUBRC EQ 0.
    E_T_DATA-UDATE = LT_JCDS-UDATE.
    E_T_DATA-AEDAT = LT_JCDS-UDATE.
    E_T_DATA-UTIME = LT_JCDS-UTIME.
    E_T_DATA-AEZEIT = LT_JCDS-UTIME.
    E_T_DATA-CHIND = LT_JCDS-CHIND.
    E_T_DATA-USNAM = LT_JCDS-USNAM.
    e_t_data-chgnr = lt_jcds-chgnr.
    IF LT_JCDS-UDATE GE L_DATE
    AND L_DATE IS NOT INITIAL.
    L_CHANGED = 'X'.
    ENDIF.
    IF LT_JEST-CHGNR NE '001'.
    CLEAR LT_JCDS.
    READ TABLE LT_JCDS WITH KEY OBJNR = LT_JEST-OBJNR
    STAT = LT_JEST-STAT
    CHGNR = LT_JEST-CHGNR
    BINARY SEARCH.
    IF SY-SUBRC EQ 0.
    L_CHANGED = 'X'.
    E_T_DATA-AEDAT = LT_JCDS-UDATE.
    E_T_DATA-AEZEIT = LT_JCDS-UTIME.
    E_T_DATA-CHIND = LT_JCDS-CHIND.
    E_T_DATA-USNAM = LT_JCDS-USNAM.
    e_t_data-chgnr = lt_jcds-chgnr.
    ENDIF.
    ENDIF.
    IF LT_JEST-STAT(1) EQ 'I'.
    E_T_DATA-ISTAT = LT_JEST-STAT.
    ELSEIF LT_JEST-STAT(1) EQ 'E'.
    E_T_DATA-ESTAT = LT_JEST-STAT.
    ENDIF.
    IF L_CHANGED EQ 'X'
    AND L_DATE IS NOT INITIAL.
    APPEND E_T_DATA.
    ELSEIF L_DATE IS INITIAL.
    APPEND E_T_DATA.
    ENDIF.
    ENDIF.
    CLEAR: LT_AUFK,
    E_T_DATA.
    ENDLOOP.
    CLEAR LT_JEST.
    REFRESH LT_JEST.
    next data package
    S_COUNTER_DATAPAKID = S_COUNTER_DATAPAKID + 1.
    ENDIF. "Initialization mode or data extraction ?
    ENDFUNCTION.

    hi,
    for that quantity SALK3 is referring a different table in the reference field for your table fields. check that field and refer the correct table for that field in table view.
    table join has a problem in that. i think your joined some other table with that field. replace the field assignment or create a new view.
    hope this help you
    regards
    harikrishna N

  • Reagrding Generic Extraction Delta

    hai
    Can anyone explain in detail with example or reak time scenarios about "Generic delta extraction for '0calday'" , "Generic Delta extraction for Numaric Pointer" , "Generic Delta extraction for timestamp" individually ..
    Please also send some documents or forums or weblog or screen shots to [email protected] now
    Thanks
    Bye
    mohammed

    Dear shylaja,
    can you please send the documents related to generic extraction to [email protected] &/  to [email protected] ?
    hope you will help.
    Waiting for your reply.
    Regards
    Vinay

  • Generic Extraction & delta

    Hi Experts,
    Can anyone tell me regarding the generic extraction and how delta happens in this case.
    regards,
    MGR

    MGR,
    Please find the below links for more better understanding about the generic delta and extraction:
    Business Content and Extractors
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/84bf4d68-0601-0010-13b5-b062adbb3e33
    ****Assign Points*********
    Gattu

  • Generic extarction delta init - bit confused

    Hi all ,
    I have created the delta for generic extraction (view in Development says.)and first time data is extracted with Inuit. delta.
      Data is in cube but how to extract the data next time ? how to do the deletion of delta ? I found the
    entry in the table ROOSGENDLM-DELTAID = '20050413' ???
    please guide for the next step after initial step .
    I will reward to the solution .
    Regards,
    Milind

    Hi Milind,
    How to extract DELTA?
    After your first INIT (Ensure that you have selected Init Request in the Info Package Update Tab). Select DELTA under the same TAB ("<i>Update Tab</i>") from the Info Package.
    Click the Start Button.
    The incoming request are now DELTAs.
    If i have helped, pls grant points...
    Bye!
    --Jkyle

  • HI could you pls explaing  generic extraction delta mechanism

    I  know what is delta . but i couldnt differentiate when we go for time stamp and numeric pointer
    i have the document for how to generic delta but inthat it is mentioned about how to use . but i want to know when shoudl i use time stamp and numeric pointer
    all answers would be rewarde

    Hi Dolly,
    Here the changed records can be isentified by :
    1. Based on the date of creation or last change ( Delta based on 0Calday)
    2. Based on the record number ( Numeric Pointer )
    3. Based on time of change ( Timestamp)
    real time examples would be
    1. Master Record creation like customer ID creation
    2. Timesheets in SAP PS
    3. Invoive details / Sales Order Details.
      Here is a weblog from Siggi for Generic Delta Extraction with Function Module.
    /people/siegfried.szameitat/blog/2005/09/29/generic-extraction-via-function-module
    Check previous posts as well.
    Generic delta
    Data Warehousing
    regards
    @jay

  • Generic extractor Delta problem

    hello,
    i have created a Generic extractor based on the AUFM table and the delta field is MBLNR (Material document no) that is a numeric pointer used for delta. My problem is that when i pull the delta not all records are being pulled. Why is that so? Can anyone give suggestions.
    thanks
    Laura.

    Well, using Function module is one approach. I can provide you another approach.
    You can create a View based on the following tables
    AUFM and MKPF,
    use the join condition
    AUFM-MANDT= MKPF-MANDT.
    AUFM-MBLNR = MKPF-MBLNR
    AUFM-MJAHR = MKPF-MJAHR
    In AUFM select all the fields that you want and MKPF select the "Accounting Document entry date" field which you can take it as delta field and select calday as your delta option.
    Once view is created, you can generate the datasource.
    Please check this option.
    I think it should work...
    Thanks
    Vj

  • Generic extraction - Delta Update

    I am creating a generic extractor to extract PM confirmations data from AFRU table. I need to make it delta enable. how do I decide which field to use for delta relevant check? any ideas?

    Hi,
    Take a look at the blog below.It is telling very well delta concept in BW.Also check how to guide.
    /people/swapna.gollakota/blog/2007/12/27/how-does-a-datasource-communicates-delta-with-bw
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/d3219af2-0c01-0010-71ac-dbb4356cf4bf
    Regards.

  • Generic Datasource Delta Settings Change

    Hi Experts,
    Currently the delta field in generic datasource is set to timestamp (LOCAL) and Upper limit is blank.
    I need to change the delta settings to timestamp(UTC) or set the upper limit to 1000 seconds.
    Can anyone tell me how to change this in production. Do i need to change this in dev and transport this to production.
    If i do the changes to generic datasource, do i have to initialise the delta again?
    Pls provide me the step by step solution.
    Regards,
    Anand

    Ananda, What about the delta initialization? After transporting the datasource from R/3 dev to R/3 production, I have to replicate the datasource right.
    In that case what will happen to my delta?.
    One more thing incase i need to change only the upper limit value.  Even for this, do i have to change it in dev and transport to production?
    Regards,
    Anand

  • GENERIC EXTRACTION DELTA SETTINGS

    HI Everyone,
                        I need to know how we set up Generic Delta in the following scenarios.
    1) When we have a Generic Extractor based on a View and this View has multiple table(For Example 2 Tables to start with).
    Then how wil you have the Generic Delta based on which field from which table? FOr example Table 1 has Header Data and Table2 has Item  Data.Our Functional  Consultant says Header can change or Item data can change.So we need to pick  up the record based on the change in each of the tables. For Example , there is a field called CHANGED DATE(AENDT) which is present in both the tables. Now , in the view if I add AENDT from Table1, then Table1's chnages will only be updated i guess. What if the change occurs in TABLE2 (ITEM).
    I dont know how to go about this. The solution is I created two Generic Extractors with two views (The only difference between the views is AENDT field coming from TABLE1 in the first extractor and AENDT field coming from  TABEL2 in the second Extractor).But I think  this  is not the best way and there must be an alternative for this
    2) The other issue is If I have a Function Module which Brings data from Multiple Tables, then how to select the field on which Delta is set.Do we need to write some Logic. After writing the logic, can we directly set the Generic Delta in RSO2 or is there any other way to do it.
    Regards,
    Samir

    Hi Samir,
    We too had a simliar requirement. In your case you can create a FM generic datasource on top of the view. The view in your case will get the intersection of the Header and Item level data.  the main challenge was to get the delta records as we can have both Orders created and changed , and in Delta can be maintained on only one field.
    To overcome this issue in the FM coding, Steps:
    create Generic datasource, with Delta on changed on date (AENDT)
    So during extraction you get the date on which the last Load was succesfully completed using the (AENDT).
    So in the selection part use the statement similar to this:
          select * from vbap into table  it_order where
                                 ( erdat  in l_r_erdat or aedat in l_r_zaedat ) and
                                 ( erdat in l_r_aedat or aedat in l_r_aedat )
    Sample generic datasource for your reference:
    http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/403b299b-94e5-2c10-a3b4-e2cecb8ee869?quicklink=index&overridelayout=true
    Hope this helps.
    Regards,
    Umesh.

  • Generic Datasource Delta upload Issue

    Hi all,
    I have created a Generic Datasource for Solution Manager ODS 0crm_process_srv_h which contains the userstatus, transaction number, transaction desc and GUID of CRM Order Object (ods key field),only these fields.
      I have taken transaction number as delta field and it is as timestamp. But delta upload is not happening. If I give GUID or Status also delta upload is not happening . Please suggest which is the best way to give to delta upload.
    Thanks and Regards,
    SGK.

    Hi,
    in your case you need to create a function module as a extractor. Create a extract structure as well and add a timestamp field (lets call it zdeltahelp) to be used as the delta relevant field of the datasource. After successful init the last extraction timestamp will be passed to the fm and you can start selecting all resb entries for orders created and/or changed from that time on as well as the ones deleted (but therefore you need to read the change documents as well). For more information about generic extraction using fm search the forum or check out my business card. There you will find a link to a weblog about that issue.
    regards
    Siggi