Run time difference on jobs creaed prior to 11/6/2011 EST and post date.

Hi,
I have a DBMS_SCHEDULER job created prior to 11/6/2011 with repeat interval. After 11/6/2011(Daylight savings change) I observed the jobs are running 1hr earlier than the time specified. They don't seem to be following the current time of database. My sysdate shows correct time. How do I enforce the schedule to follow sysdate time with Daylight savings enabled.
DBMS_SCHEDULER.create_schedule (
schedule_name => 'SCH_Holidays',
repeat_interval => 'FREQ=YEARLY;BYDATE=20110101,20111104,20111107;',
comments => 'Static Holidays'
BEGIN
DBMS_SCHEDULER.create_job (     
job_name => 'EMAIL_REPEAT',
job_type => 'PLSQL_BLOCK',
job_action => 'BEGIN
NULL;
END;',
start_date => SYSTIMESTAMP,
repeat_interval => 'freq=DAILY; BYDAY=MON,TUE,WED,THU,FRI; BYHOUR=2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20; BYMINUTE=0,15,30,45; EXCLUDE=SCH_Holidays;',
enabled => TRUE,
comments => 'EMAIL REPEAT JOB EVERY 15 min Starting from 2:00 till 20:00'
END;
select LOG_DATE,JOB_NAME from dba_scheduler_job_run_details where LOG_DATE >trunc(sysdate-3) and JOB_NAME='EMAIL_REPEAT'
LOG_DATE JOB_NAME
04-NOV-11 02.00.46.853302 AM -04:00 EMAIL_REPEAT
07-NOV-11 01.00.52.908917 AM -05:00 EMAIL_REPEAT

On our database here is the output of what patches are applied. Does any of the patches not applied contributing to this behaviour ?
V3 (or later) Time Zone Update is applied
V4 (or later) Time Zone Update is applied
V6 tzdata2007f (or later) Time Zone Update is not applied
V7 tzdata2007k (or later) Time Zone Update is not applied
V9 tzdata2008f (or later) Time Zone Update is not applied
V10 tzdata2008i (or later) Time Zone Update is not applied
V11 tzdata2009g (or later) Time Zone Update is not applied
V13 tzdata2009s (or later) Time Zone Update is not applied
V14 tzdata2010i (or later) Time Zone Update is not applied
V15 tzdata2010o (or later) Time Zone Update is not applied
V16 tzdata2011g (or later) Time Zone Update is not applied

Similar Messages

  • Run time Error in accessing Analyzer on VIsa 64 bit, Office 2007 and SAP GU

    Hello experts-
    I can not run Bex Analyzer using WINDOWS VISTA HOME PREMIUM 64 bit OS, Office 2007 and SAP GUI 7.10
    I am receiving Run time error "5" and does not let me open or create a new query. Please share your experience and thoughts so that I could be able to fix this issue
    Thanks

    Hi Suresh,
    Check the RFC connection of Source system. It seems that your rfc connection is not working properly. So make sure that you are able to establisthed the connection between these 2 systems.
    Regards
    Subhash

  • Need advice on running timer based cron jobs

    Hi,
    We made a cool desktop product on Flex that runs on the Air environment. After having released it a while ago, we think about taking its performance to the next level by being able to mimic cron job like functionality based on timers.
    However, one of the setbacks for us while we tried to do something similar earlier was the Flash platform's single threaded architecture. So if we are running something resource consuming in the background, chances are that the UI might get stuck if a part of it is being rendered. That will make things looks ugly and we are trying to find ways to make it work.
    Can anyone recommend anything that would help?
    Thanks!
    Vivek

    > 1. What is the best fastest system AE can take advantage of? If we get 6 or 8 or 12 core Mac Pros (instead of the quad core) with more RAM, would AE be able to access that speed, and if so up to how many GB can it use, only up to 2GB per core or can it use more?
    Yes, After Effects will take advantage of multiple fast CPUs and all of the RAM that you can install.
    You also want to have a decent-sized SSD connected over a fast bus for the disk cache. The new Mac Pro does very well in that regard.
    2. Should we replace the graphics card with an Nvidia CUDA? Is the ray-tracing engine something we’ll need with Cinema 4D work?
    The After Effects ray-traced 3D renderer has nothing whatsoever to do with Cinema 4D.
    Do not make any buying decisions based on the  After Effects ray-traced 3D renderer unless you already know for certain that you have a need for it. Since you're asking, it seems that the answer is that you don't.
    See this page for information about hardware for Premiere Pro and After Effects: http://adobe.ly/pRYOuk

  • HT201250 When I open time machine, everything outside of the last 5 weeks is faded and the dates are gone.  Have I lost those back-ups?  Thank you.

    When I open time machine, I only see dates of the last 5 weeks.  The bars before those dates are faded with no dates beside them.  Did I lose those backups?  Thanks for your help.

    Most commonly used backup methods

  • What is GL account, difference bet. Doc.date and posting date, etc.

    Hello Experts,
    Currently I am supporting reports/programs for FI module. Can anybody please help
    me or give me walkthrough on what are the terms like posting key, document date,
    posting date, type, account, etc. I am currently modifying a report which posts in
    transaction F-02. Any tips and guides will be highly appreciated. Thanks guys and take care!

    Hi,
    <b>GL Account:</b> This field contains the number of the G/L account to which the transaction figures are updated.we use One gl account for Salaries in an Orgn, and for expenses one GL like that.
    <b>Document Date</b>: The document date is the date on which the original document was issued.
    <b>Posting date:</b>Date which is used when entering the document in Financial Accounting or Controlling
    The fiscal year and the period for which an update of the accounts specified in the document or cost elements is made, are derived from the posting date.
    When entering documents, the system checks whether the posting date entered is allowed by means of the posting period permitted.
    The posting date can differ from both the entry date (day of entry into the system) and the document date (day of creation of the original document).
    <b>Posting Key:</b>The posting key describes the type of transaction which is entered in a line item.
    For every posting key, you specify properties which control the entry of the line item or are noted in the line item itself.
    The most important properties which are derived from the posting key are:
    The account type
    The allocation to the debits or credits side
    The possible or necessary specifications which are to be entered in the line item.
    <b>DocType:</b>The document type classifies the accounting documents. It is stored in the document header.
    Attributes that control the entry of the document, or which are themselves noted in the document, are defined for each document type. In particular, the number range assigned to the associated documents is defined on the basis of the document type.
    reward if useful
    regards,
    Anji

  • Exporting DI batch to BAT and set DI parameter/variable at run time

    Hi All,
    We are looking to call DI batch job externally and pass parameter/variable at run time.
    We tried exporting DI batch to a bat file and setting substitution parameters during export.
    In the exported .bat file, it references a .txt file which shows the name of the substitution paramemters but the value of the parameters are encrypted.
    Does anyone know how to pass parameter/variable to a DI batch job at run time externally?
    Thanks,
    Bobby

    I tried out this method and I have some additional issues.
    1. if we use the BOE scheduler the text parameter file is using a specific naming convention that is not clearly documented. it is like : -GV"$VAR=ENCRYPTEDVALUE;"... trying to modify it with a clear value like -GV"$VAR=MYVALUE;" was simply ignored by the scheduler... seems also that BOE did not sent any scheduling request to the DI Job Launcher...
    What is the proper convention please?
    2.Is there a better way to enter this parameter than editing the TXT file. Most of the BOE InfoView users are not allowed to modify or store documents.. This is not very convenient if they cannot enter simply the parameter values in a let say more confortable way...
    Thank you and cheers

  • Upgraded from LabVIEW 8 to 2013 and now VI asks to find the installati​on package for Run-Time Engine 7.0

    I recently installed LabVIEW 2013 on a computer (running Windows XP 32-bit).  The machine also has LabVIEW 8 installed, which is what I was using prior to upgrading.  I opened a VI that was created in LV8 and then saved it and all its subVIs in LV2013.  Now when I open the VI in LV2013 and try to run it, a window pops up asking me to find the "lvruntimeeng.msi" installation package for LabVIEW Run-Time Engine 7.0.  If I cancel that dialog box and the subsequent message stating that the installion files were not found, the VI appears (at least from intial inspection) to run normally.
    I closed LabVIEW, downloaded Run-Time Engine 7.0 from the NI website, and tried to install it, but I received a message saying that it is already installed (as I had suspected).  How can I determine what part of the VI and/or its subVIs is trying to make use of Run-Time Engine 7.0?  Alternatively, how can I get LabVIEW to instead use the Run-Time Engine 2013 that was installed when I upgraded to LabVIEW 2013?
    Solved!
    Go to Solution.

    Bob_Schor wrote:
    Are you running your VI from a Project?  If so, you can look at Dependencies and get an idea what "dependent" VIs you might have.  There may be "something old" in your LabVIEW 8 code that has been superceded in 2013, but still "hangs around" -- if you can identify it, you can probably replace it with its "more modern" equivalent.
    If you do not have the VI in a Project, you can simply open LabVIEW, create a new blank project, and add your top level VI to it.  If all of your relevant VIs are in a single folder, add the entire folder.  Now look in Dependencies.
    BS
    Yes I am running the VI from within a LV Project.  After some more searching in the NI Knowledgebase I was able to fix the problem by using the following procedure:
    1.  Use the Measurement and Automation Explorer to uninstall Run-Time Engine 7.0
    2.  Restart the PC
    3.  Open the project, close the project choosing to "save all"
    4.  Restart the PC
    5.  Re-install Run-Time Engine 7.0 using a file downloaded from ni.com
    6.  Restart the PC
    7.  Open the project, close the project choosing to "save all"
    8.  Open the project and run the VI.  No more messages about LabVIEW trying to find Run-Time Engine 7.0.

  • List of BO reports failing daily and schedule run time

    Hi,
        Our BO reports are scheduled to refresh daily early mornings 2 - 6 AM and around 280 reports run daily. We want to know list of failed reports daily and measure run time differences for each report in different days and run time for all 280 reports.
    1. List of failed reports (to check if same reports are failing daily)
    2. Total run time for all reports
    3. Change in run for each report on different days.
    Could you please let me know how this kind of report can be generated.
    Regards,
    Nanda Kishore B

    Hello Nanda Kishore,
    Check below two links which can be helpful:
    For query builder, below link has a 4 part series of queries. You can find the other links at the bottom on the page
    BusinessObjects Query builder queries
    If you are using BI 4.x, then below link has a set of sample auditing universe and reports.
    I'm sure you can find the required reports in the attachment:
    Sample Auditing Universe and Reports for SAP BusinessObjects_4_x
    I think auditing would be the best way to get the information required.
    I hope this helps!
    -V

  • Does OS effective battery run time/life?

    I really do not have a preference to which OS that I use, either XP Pro or Vista Business (although have never used Vista before) but I am wondering if using one verse the other would help increase and stretch the battery life.  If all things being equal as far as functions, radios turned on, screen brightness and such, will one give me longer run times than the other?
    I have read a few entries and there seems to be more updates, revisions and features are being developed and put into Lenovo's management systems for Vista, so I am wondering if perhaps that would have any difference as well.
    One more thing, has there been any updates/upgrades since Feb or March that would make a difference in the run time of the battery life with either Vista, XP or any of the Lenovo management systems?  I ask because I read the review at notebookreview and I was shocked that they only got about 3 1/2 to 4 hours of use from the X300 and the T400 is getting over 6 1/2 hours and both machines are using 6 cell batteries.

    Hello DanMgy,
    Vista out of the box and without tweaks like disabling aero or the sidebar may consume more power,
    than an normal XP.
    But Vista will give you more options to safe power, and a well tweaked Vista, seems more effective
    than a normal XP. But in this case, it will problably having the look, as good old XP.
    Follow @LenovoForums on Twitter! Try the forum search, before first posting: Forum Search Option
    Please insert your type, model (not S/N) number and used OS in your posts.
    I´m a volunteer here using New X1 Carbon, ThinkPad Yoga, Yoga 11s, Yoga 13, T430s,T510, X220t, IdeaCentre B540.
    TIP: If your computer runs satisfactorily now, it may not be necessary to update the system.
     English Community       Deutsche Community       Comunidad en Español

  • Does OS effect battery run time/life?

    I really do not have a preference to which OS that I use, either XP Pro or Vista Business (although have never used Vista before) but I am wondering if using one verse the other would help increase and stretch the battery life.  If all things being equal as far as functions, radios turned on, screen brightness and such, will one give me longer run times than the other?
    I have read a few entries and there seems to be more updates, revisions and features are being developed and put into Lenovo's management systems for Vista, so I am wondering if perhaps that would have any difference as well.
    One more thing, has there been any updates/upgrades since Feb or March that would make a difference in the run time of the battery life with either Vista, XP or any of the Lenovo management systems?  I ask because I read the review at notebookreview and I was shocked that they only got about 3 1/2 to 4 hours of use from the X300 and the T400 is getting over 6 1/2 hours and both machines are using 6 cell batteries. 

    As a rule of the thumb, XP gives better battery life than Vista, at least on the machines that I've had both on which would include T42p, T43p, X61s (ultralight LCD) and T61p.
    Hope this helps.
    Cheers,
    George
    In daily use: R60F, R500F, T61, T410
    Collecting dust: T60
    Enjoying retirement: A31p, T42p,
    Non-ThinkPads: Panasonic CF-31 & CF-52, HP 8760W
    Starting Thursday, 08/14/2014 I'll be away from the forums until further notice. Please do NOT send private messages since I won't be able to read them. Thank you.

  • Can't install LabVIEW Run-Time Engine 6.1 on Windows Terminal Server

    With my system admin, we tried to install the LabVIEW Run-Time Engine 6.1 on our Windows Terminal Server NT4. And we get an error all the time:
    -install using the plugin
    -install using LVRTE.exe
    -install after rebooting the server
    But I remember that we could install the Run-Time Engine 6.0 on another Windows Terminal Server NT4.
    Is there any compatibility issues with the new Run-Time Engine 6.1 ??
    Thanks for your help
    Cyrille

    Cyrille,
    What is the error that you get when trying to install the run-time engine?
    Are you installing it from the LabVIEW CD, or did you download it from the web site?
    To further troubleshoot this problem, it would be best if you send us an email to [email protected] and send the above information.
    Also, try running the installer from the command prompt window, and use the following syntax:
    setup.exe/l*v
    This will save the error log to the file you specify. Send us also this file to help us troubleshoot.
    Thanks
    Zvezdana S.
    National Instruments

  • NI 5660 Driver DLL Errors when using Teststand 2010 and LabVIEW Run-Time Engine 2010

    This problem seems similar to the post "Resource not found error in executable on developmen​t machine." but I didn't want to repost under that thread because I only happened upon it by chance and none of my searches brought me there... so I made a more descriptive Subject.
    I am working on a system that uses a PXI Chassis with a NI 5600 Downconverter and a NI 5620 high speed digitizer, among other PXI Cards. 
    I inherited working code written in LabVIEW 2010, running with the LabVIEW Run-Time Engine 2010.  The code was using a custom executive and my task was to rewrite the test using TestStand 2010.  I reused the majority of the old code.  The old code used NI-5660 to control the 5600 and 5620.  When I run my sequence using the LV Development System and TestStand, it runs without any issues.  When I change the adapter over to LabVIEW Run-Time Engine 2010, all of my NI5660 VIs become broken due to DLL issues.  It warns that the nipxi5600u​.dll was not initialized correctly.  Many of the errors are associated with the NI Tuner and NI Scope. After this LabVIEW will crash randomly, and the seqeunce will not work in TestStand even when back with the LV Development Adapter.  The only way to recover after this is to restart the computer - TestStand automatically reverts back to the development system, the VIs are no longer broken and the sequence works again. 
    I have all of my VIs associated with a project. After reading a little bit about DLLs and TestStand, I found all of the DLLs in the dependencies section of my project and added them to my TestStand workspace.  I also used Dependency Walker to track down the problems with the nipxi5600u​.dll, the 2 DLL files that it said were not found already existed in the same folder as the original DLL (C:\Windows\System32).  I have also performed a Mass Compile to make sure everything was running in LV 2010.  If I skip the steps involving the 5660, my entire sequence runs fine. 
    The previous code was running with the LabVIEW Run-Time Engine without any issues.  Is there just a step I am missing?  Has anyone seen anything like this before?  I can send screenshots of errors to provide more detail if necessary. 

    I have tried some more things and still can't get it to work.  I have added the VIs mentioned in the Notes On Creating Modulation Executables KB both to the TestStand workspace and the LabVIEW project holding all of my VIs.  This did not change the results. 
    When I try to run my sequence, The first error I get is shown in Error 1445.bmp.  This happens when I try to use the NI 5660 initialize.vi.  If I click ignore, the next error I see is shown in Error -20551.bmp.  When I try to open the VI to look at it, I get the 2 DLL errors shown in Error loading nipxi5600u.bmp and Error loading nidaq32.bmp.  When I close TestStand, I get the error LabVIEW Fatal Error.bmp. 
    Attachments:
    Error1445.JPG ‏164 KB
    Error -20551.JPG ‏174 KB
    Error loading nipxi5600u.JPG ‏9 KB

  • How to do validation on multi record block at run time...

    Dear Friends,
    I have to do validation at run time on multi record block.
    If user tries to enter and save two or more records in same multi record block with same data at run time, it should not allow it and display a message like, " error : Records are having same(duplicate) values. "
    I already did validation with the data coming from database table using cursor. But confused about how to do at run time(on one screen only) ??
    Please, give details about how to check duplicate records on form block before saving it to the table ????
    Regarding details would be greatly helpful.
    thanks,

    Hi...Pankaj
    thanx for your reply..
    I already did validation for the data coming from table....
    but I need to do it on form only...at run time...
    exa...
    In one multi record block
    record no : column 1 : column 2 : column 3
    1 abc 123 hi
    2 abc 123 hi
    so it should check on the form itself, here I m not getting data from table...I am just
    navigating from first record to second using down arrow.
    so, may be 2 possibilities.
    1) when user navigates using tab to third record, it should say like two duplicate records.(may be like when validate record or item)
    2) or when user tries to save, it should say two duplicate records.
    so, everyting should take place on form screen only.....
    waiting for your reply,
    thanx...

  • Install labview 6.1 (or compatible) run-time engine with labview 2011

    I have installed a trial period version of Labveiw 2011 in order to check for possible upgrade issues I may have if I decide to upgrade from labveiw 6.1. Well, needless to say there have been alot. That is as expected since I have not updated labview in many years. I am still not under any pressure to update; however, I would like to in order to get support and make sure I do not have any compatibility issues with new  equipment purchases. I have been able to resolve most of my compatibility issues with simple code fixes and such. However, twice now I have run into an error when launching labview executeables compiled by two different equipment manufacturers. The equipment I am using is not even old...maybe a year or so. When I launch the labview executables to control this equipment on a PC that has the trial period labview 2011 installed, I get an error message stating something like " This requires a Labview 6.1 (or compatible) run time engine." I have tried to download and install the 6.1 labivew engine but I can't install this engine on a PC which has labview 2011 installed. Can someone explain how I am to run these executables under labview 2011. I can't imagine these executables were developed using 6.1 since this equipment is not even a year old now.
    Solved!
    Go to Solution.

    Im not for sure I am on the same page with you here. Im not trying to develop any code myself. I have some labview executables that came with hardware we purchased in order to control it. We used to have labview 6.1 installed; so everything was working ok. But now that I have installed 2011, I get an error message when trying to run these executables. The error message states that this executable requires a labview 6.1 or compatible run-time engine. I have seen this error on both XP and Windows 7 machines. I did not develop the executable, it was developed by the hardware manufacturer. But since this hardware is only about 1 year old, I an assuming they used a newer version of Labview to develop this code. Certianly newer than 6.1.
    So I guess my question is..is there a way for me to get this executable to work on a PC that has labview 2011 installed. I have tried to install a labview 6.1 run time engine but it will not install. Any other options?

  • How to get the Title and Tcode of a Program during run time

    Hello,
    I am new to abap and I have this question please. Is the a way to get the title, Tcode and Author of a program during run time? I would like to get the name and title of a program or a view or an include during run time.
    Using table TADIR, you can only get the object_name and the author. Is the a way for me to get the Title of the repository object and any Tcode if any is available for the case of a program?
    I loop forward for your respond.
    Thank you.
    Sabina

    You can get it by accessing SYST.
    SY-TITLE for Title
    SY-TCODE for Tcode
    I don't think there is any field in SYST for the Author.
    To get the author name you can use the TRDIR table.
    Regards,
    Naimesh Patel

Maybe you are looking for