Runtime parameter rdisp/max_wprun_time is set to 1700

u201CCaller 70u201D missing error. This is happening because the runtime parameter rdisp/max_wprun_time is set to 1700. If I edit it to 15000 temporarily and re run the load, the load is successful.
this is popping up at the point of updating data targets, in the 1st set of data package while the second loads successfully.
Krishna.

The runtime parameter rdisp/max_wprun_time defines the time limit for a foreground process. While backgound processes are permitted to run with out any limit. With this parameter the foreground/dialog processes are permitted to run for the defined amount of time, beyond this the system will cancel them terming it as time limit exceeded error.
The standard defined by SAP for this parameter is 3600, but depending on our business need we can increase or decrease this value. Usually taken care by Basis Administrators.
Regards,
Habeeb

Similar Messages

  • BASIS Parameter rdisp/max_wprun_time

    Hi,
       Does anybody knows how the time limit given in the profile parameter rdisp/max_wprun_time work?
    I mean our parameter is set to 3600.  What does that mean? Does it mean that it will kill dialog process at 3600 secs or 7200 secs?
    Today our system almost came down as there were bex users (mostly with killed excel programs) which still had a process in SAP running for more than 40000 secs.  Any idea why the parameter didnt work?
    Also if the parameter gives two times its value before the dialog work process is killed why today I saw one dialog process getting killed at 3600 secs in sm66 shouldnt it get killed after 7200 seconds.
    I though the parameter is defined such that if rdisp/max_wprun_time=n then maximum dialog process runtime would be 2n and after n seconds smm66/sm51 would show up as red and after 2n it would be cancelled altogether...
    please help

    Hallo BWNovice
    The parameter is giving you maximum time for Dialog Process - for example when you run a bex query. The default is 600 sec but yo0u can extend as much as you want I suppose. But be carefully because then you can have process which run for 6000-7000 thousand seconds which can affect macvhine performance (depend on your machine). Usually 3600 is a good time, thinking also for the loading during the night where you can have some dialog processes which takes some time.
    Regarding your question: if you have it set-up 3600 and you run a bex report which takes more than 3600 at 3600 then the process will be killed by the system.
    But a suggestion: you should avoid to have process which run so long time in your machine, specially bex report.
    I hope this can help you.
    Mike

  • Determine/read the value of parameter rdisp/max_wprun_time within ABAP

    Hi,
    I need to avoid program breaks caused by exceeding run time longer than defined in parameter rdisp/max_wprun_time.
    I will check the time since start of report in the critcal loop to bring the current data changes to a controlled end before getting a program break. I won't put a constant to the report, I will have a dynamical routine to avoid changes of report if the value of parameter rdisp/max_wprun_time will be changed.
    But how can I get the value of this parameter within my ABAP report? Is there a table where this value has been stored? Is there an existing function module or a method to read the value?
    Thank's a lot in advance!
    Georg

    The runtime   parameter (GET RUN TIME ) can be used to dynamically get the program run time
    DATA T TYPE I.
    GET RUN TIME FIELD T.
    WRITE: / 'Runtime', T.
    or
    U probably can store the start date and time in TVARV with some variable ( line concatenate program name + START Date + Time)
    and then use
    SD_DATETIME_DIFFERENCE
    or
    SD_CALC_DURATION_FROM_DATETIME
    Regards,
    Mithun Shetty

  • The system profile parameter rdisp/max_wprun_time  how to cinfigure this in ecc system

    Hi,
    Can any body tell me the procedure how can we configure the the system profile
    parameter rdisp/max_wprun_time  in ecc system step by step procedure
    Regards
    Madhu

    Hi Madhu,
    If we change the max parametere here my be our problem will solved right.
    See this link is usefully
    http://scn.sap.com/thread/2045008
    Adding some comment to that rz-10 is different than RZ10?
    There is no t-code like rz-10.
    rz10 is the t-code for profile parameters
    Regards,
    Deva

  • Changing rdisp/max_wprun_time

    I have a third party program which uses a back ground account to connect to SAP and run ABAP.  This ABAP program is taking longer than 5 minutes and it is timing out with error:
    SR_17009 Error in CPIC: [CMRCV: 18 Time limit exceeded
    Current I am using SAP R3 4.x and will be moving to SAP ECC 6.x in future.
    I have read that one can change following parameter
    rdsip/rdisp/max_wprun_time   to change the default time.
    I have  following questions, some of them are naive:
    1. Does a background account(my third party cannot login interactively) still use Dialog Processes.
    2. I am assuming I have to create s special profile for setting this parameter so it does not affect other accounts. What command do you use to create this profile.
    3. What command do I use to assign my third party account to this profile.
    4. How do I found which account has which profile.
    THANSK A LOT.

    Zigzagdna,
    The parameter rdisp/max_wprun_time is not user or profile specific. It affects the entire system. Simply defined, it defines the amount of time a dialog work process can be occupied by one step (can be seen in SM50). Which user you use to run/call the ABAP program, does not change or decide the time.
    1. Does a background account(my third party cannot login interactively) still use Dialog Processes.
    Yes, it can. Most program need both dialog work processes and background.
    2. I am assuming I have to create s special profile for setting this parameter so it does not affect other accounts. What command do you use to create this profile.
    No, you dont need a profile.You can change this value from the Tcode RZ11.It can be changed and the new value is taken into effect without restarting the SAP system (dynamically switchable).
    3. What command do I use to assign my third party account to this profile.
    Not applicable
    4. How do I found which account has which profile.
    Not applicable
    I dont have the exact info of your program, but from what it sound like, it could be timing out because of RFC timeout. If it is not running from the SAP Gui, it must make RFC calls to the server.
    Kunal

  • Java console runtime parameter not working

    I'm tring to increase the size of memory available to my applet by adding a java runtime parameter in my Java Console. The runtime parameter is: Xmx512M
    Which changes the deployment.properties file to:
    #deployment.properties
    #Mon Nov 22 14:46:50 GMT-06:00 2004
    deployment.browser.vm.iexplorer=true
    deployment.browser.vm.mozilla=false
    deployment.version=1.5.0
    deployment.console.startup.mode=SHOW
    deployment.system.tray.icon=true
    deployment.capture.mime.types=true
    deployment.browser.path=C\:\\PROGRA~1\\MOZILL~1\\FIREFOX.EXE
    #Java Web Start jre's
    #Mon Nov 22 14:46:50 GMT-06:00 2004
    #Java Plugin jre's
    #Mon Nov 22 14:46:50 GMT-06:00 2004
    deployment.javapi.jre.1.5.0.args=Xmx512M
    deployment.javapi.jre.1.5.0.osname=Windows
    deployment.javapi.jre.1.5.0.osarch=x86
    deployment.javapi.jre.1.5.0.path=C\:\\Program Files\\Java\\jre1.5.0
    But when I run the applet I find that my max memory has not been changed from the default (65MB). I can thell this by outputting the max memory:
    System.out.println("Memory Max = " + Runtime.getRuntime().maxMemory());
    This line results in the output:
    Memory Max = 66650112
    So this output makes me believe that the runtime parameter is not being set correctly . When I run my applet in an executable jar locally (java -Xmx1024M -jar myApplet.jar) it sets the runtime parameter fine and memory is increased as expected.
    Am I doing something wrong in the Java Control panel? Is my syntax incorrect?

    I had no problem using IE6 or mozilla 1.7.3
    html file
    <OBJECT ID="SUN" WIDTH=500 HEIGHT=120 CLASSID="CLSID:8AD9C840-044E-11d1-B3E9-00805F499D93">
    <PARAM NAME="code" value="Test.class">
    </OBJECT>class file
    public class Test extends java.applet.Applet {
        public void init() {
              System.out.println("Memory Max = " + Runtime.getRuntime().maxMemory());
    }deployment props
    #deployment.properties
    #Fri Nov 19 10:38:15 CET 2004
    deployment.browser.vm.iexplorer=false
    deployment.browser.vm.mozilla=true
    deployment.version=1.5.0
    deployment.console.startup.mode=SHOW
    deployment.system.tray.icon=true
    deployment.capture.mime.types=true
    deployment.browser.path=C\:\\Program Files\\Internet Explorer\\iexplore.exe
    #Java Web Start jre's
    #Fri Nov 19 10:38:15 CET 2004
    #Java Plugin jre's
    #Fri Nov 19 10:38:15 CET 2004
    #deployment.javapi.jre.1.5.0.args=-Djavaplugin.trace\=true -Djavaplugin.trace.option\=basic|net|security|ext|liveconnect
    deployment.javapi.jre.1.5.0.args=-Xmx512M
    deployment.javapi.jre.1.5.0.osname=Windows
    deployment.javapi.jre.1.5.0.osarch=x86
    deployment.javapi.jre.1.5.0.path=C\:\\Program Files\\Java\\jre1.5.0Output of the applet:
    Memory Max = 532742144

  • Multiple Users on one PC sharing Java Runtime Parameter setting

    Is there a way to have mutiple logins share the -Smx512m setting in Java Runtime Parameters. It seems that when each person logs into the PC to use the application we have to enter the same Java Runtime Parametes again. Is there a way to add it once and every login uses it?
    Thanks,
    DLS

    I have read the Deployment Configuration file and Properties and do not see how the -Xmx51m should be added to the deployment.properties.
    Also it would seem you would need to use the deployment.system.config file so it would be used by all users on the PC.
    Again I can not see an example of how to put in the "Java Runtime Parameters" in the deployment.system.properties file.
    Has anyone done this before and could lead me in the correct directions?
    Thanks,
    DLS

  • How to set runtime parameter for the entire system

    Hi,
    I have a problem with setting runtime parameters in jre v1.6.0_07. I have an XP computer with multiple users and to use the application eavery user must set the runtime parameter once by going to java control panel -> Java -> Java applet runtime settings -> view. How can i automate this? I have multiple users and there may be more users logging in so manually sending the C:\<userProfileDirectory>\Application Data\Sun\Java\Deployment\deployment.properties file to all profiles is not a solution. Same question here but no solution. Every user must get this parameter when they log in, they may be new users or existing users. The software I'm trying to use is browser based, we don't trigger an exe or something from local to run the software.
    In C:\<userProfileDirectory>\Application Data\Sun\Java\Deployment\deployment.properties file there is a line like this;
    deployment.javapi.jre.1.6.0_07.args=
    This works for a single user. I've read the instructions in [deployment guide|http://java.sun.com/javase/6/docs/technotes/guides/deployment/deployment-guide/properties.html] but the properties file we put in C:\WINDOWS\Sun\Java\Deployment does not support ".args=" command. Anyone encountered or have a solution for this problem?
    Thanks.

    Hi,
    got solution for this problem? I am also having the same problem.
    Thanks.

  • Setting Profile parameter rdisp/gui_auto_logout value

    Hi All,
    The present value for the profile parameter value rdisp/gui_auto_logout is 1200 sec, now i would like to change the value from 1200 sec to 2400 sec.
    can change the value directly in parameter value field (using  T-code RZ10) or can i create a new parameter value?
    Please any one give me the suggestions how to reset the value for this profile parameter
    Regards,
    Reddy V,

    Hello reddy,
    This rdisp/gui_auto_logout parameter can be changed dynamically too you can change the value via RZ11 if you dont want to restart your server now. but in this case whenever you will restart your server the parameter value will be set back to the original state
    change it via RZ10 but in this case you have to start the server to activate this value
    Select Change in instance profile via RZ10 and select extended maintainance then click on create parameter and enter the parameter name there and press enter, it will show you the current value then insert the new value and save and activate the profile.
    Regards
    Subhash

  • How to redirect "-verbose" Java Runtime Parameter setting to text file

    Simple question: I am adding a "-verbose" Java Runtime Parameter in the Java Applet Runtime Settings of the Java Control Panel. When I run my applet, a Windows console opens which outputs all the method calls, classes, and jar file information. How can I redirect this output to a text file?
    I noticed Xloggc:+filename+ but there does not seem to be an equivalent for redirecting the '-verbose' output to a file.
    Thanks!
    Edited by: zillius on Dec 14, 2007 1:47 PM

    Thank you both for the reply, but unfortunately that is not quite what I am looking for. The console Window I am talking about is a DOS console screen, not the Java Console
    What I am really after here is the ability to redirect a thread dump of a running applet to a text file. When the applet is active, and the "-verbose" parameter is set in the Java Runtime Parameters", I can see all the classes, methods etc. being loaded in the DOS window. Hitting Ctrl-Break at that point will produce a thread dump in the DOS console screen. I would like to be able to redirect THAT output to a text file. It is not in the Java Console. To me it looks like tracing and logging are only for the Java Console, no?
    Thanks again for your help.
    Edited by: zillius on Dec 19, 2007 7:17 AM

  • How to hide the window of Runtime Parameter Form?

    I have a form and I call a report from this form.I have passed some parameters to this report.Before the browser of reports appear the window of Runtime Parameter Form.I want to hide this window of Runtime Parameter Form but I don't know how.
    Please help me!

    When calling the report, set the property PARAMFORM to NO. IF you using parameter list to pass values to report you can do as follows:
    ADD_PARAMETER(pl_id,'PARAMFORM',TEXT_PARAMETER,'NO');

  • Java runtime parameter (-classpath)

    Hi,
    Does anyone know how to programmatically set the java-runtime-parameters?
    I need to set them to: "-classpath c:\jar\test.jar"
    My goal is to access test.jar thru the ActiveX Bridge, and test.jar is not inside the "applet" folder (nor the "ext" folder). Note: ActiveX bridge uses the java plug-in which has a default path to the applet folder, I need to programmatically set a java-runtime-parameter "-classpath" to c:\jar\test.jar...
    (I know that you can set the java-runtime-parameters thru control panel - java plug-in, but this will not work for what I am doing, I need to do it on the fly programmatically).
    Gene.

    People I have tried this after trying all that I could fine on the internet,
    What did not work is as follows:
    1) Setting "-Xmx512m", where "512" should be replaced by 3/4 of the system
    physical memory size.
    2) Also enable "<APPLET> tag support" for Internet Explorer. Apply settings.
    This worked for some.
    3) Also tried uncheking the box for <APPLET> but that was not to work.
    "What --WORKED-- for me at last was:"
    1. Uninstall Internet Explorer 7.
    2. Restart System.
    3. Uninstall Java 1,5 with Update 9(that was installed)
    4. Install Java version 1.5 with upgrade 5 from the link:
    http://www.tucows.com/preview/194327
    5. Then go to Start, Run, type
    iexplore
    and hit Enter.
    Try the sites now.. It works:)
    6. Then disable update for Java in Control panel. (Also do not update IE or
    JAVA after that)
    Hope this help ya all!!!

  • Msprot: cant read profile parameter rdisp/mshost

    Hi
    When I run : msprot -name <SID> -l it returns:
    cant read profile parameter rdisp/mshost
    rdisp/mshost is set in the default profile to : sapms<SID>
    in etc/services  sapms<SID> is assigined to   <port_number>/tcp
    If you change rdisp/mshost to the port number rather than sapms<SID> it works....but we don't want to change the parameter to the port number.
    Thanks
    Jim

    Thanks.....i've being testing the command....it's like it can't read the default profile...
    if i use mshost switch it complain it can't read msserv.....once I use both switch it runs ok....
    I changed default profile to 777 just to test if it was a permissions issue but that didn't make a difference.
    Thanks for the note but that seems to be dealing with windows...i'm working on sun...tried it on linux also and get
    the same problem....
    Cheers
    Jim

  • Parameter log_parallelism is not set on Oracle 10.2.0.1.0 on linux

    when i am trying to set following parameter, oracle 10g (10.2.0.1.0) is giving me error.
    As i am trying to setup Standby database and in Production database, it is required to set this parameter
    SQL> ALTER SYSTEM SET LOG_PARALLELISM=1 SCOPE=BOTH;
    ALTER SYSTEM SET LOG_PARALLELISM=1 SCOPE=BOTH
    ERROR at line 1:
    ORA-02065: illegal option for ALTER SYSTEM
    SQL> ALTER SYSTEM SET LOG_PARALLELISM=1;
    ALTER SYSTEM SET LOG_PARALLELISM=1
    ERROR at line 1:
    ORA-25138: LOG_PARALLELISM initialization parameter has been made obsolete

    Refer Metalink note 268581.1
    and
    http://download.oracle.com/docs/cd/B19306_01/server.102/b14238/changes.htm#i638194
    For my information, why do you need to set this parameter in your scenario?

  • How can I find out if the rollback optimal parameter size has been set ?

    What is the command to find out if the rollback optimal parameter size has been set? And what is the command to find out what is the rollback optimal parameter set to?

    You can find the OPTIMAL size in v$rollstat.optsize

Maybe you are looking for