Sending IDOCS through transaction PFAL

Hi,
We have a requirement to send idocs through transaction PFAL for a set of PERNRs for all infotypes.What is the way to go about this?
Thanks ain Advance!
Regards,
Nejuma Iqbal

hi
you cannot send IDocs thru PFAL transaction.
you can send HR Master Data thru PFAL.
yes you can send the Pernrs as they are Components of Organizational Elements.
Here is the Procedure to send Personal Numbers:
1.Execute the transaction PFAL.
2.Give the object type as P.
3.Give the Pernr values in Object ID field
4.Select the transfer mode as Update
5.In the Receiving Partner give your receiver name
6.Give the message type as HRMD_A in the Message Type field.
7.Dont change the remaining values.Keep it as such.
8.Execute the Program.
Also keep in mind that while sending the HR data you need to follow the certain sequence
unless otherwise your data wont be replicated successfully.
Here is the sequence O,S,P and C.
Means before sending P  you should send O and S.
Cheers,
Abdul Hakim
Mark all useful answers..

Similar Messages

  • Sending IDOC through INOT

    I want to create IDOC for transaction IW29( display notifications) . For this i am using transaction  INOT (send notification). But when i am executing INOT ( using notification no , user status field, and target system fields ) its showing -- No IDOCs created. Kindly help in  solving the issue.
    Thanks.

    Ferry,
    I think this may be what you are suggesting, but in different words.  Either way, it would likely solve the problem, though not as cleanly as I'd like since now I've got to make changes to the MB_CREATE_GOODS_MOVEMENT BAPI.
    (1) create a new segment called ZZSDATA1
    (2) make this segment a child of the E1BP2107_GM_ITEM_CREATE segment
    (3) put the overflow information in the new segment
    I can't just add another field to the segment, with 1 byte or 1000 bytes.  All of the data for the segment has to fit within one 1000 byte sdata field.

  • Infotype Data Upload through transaction PFAL

    Hi All,
    Is there any option to distrubute data infotype wise in the transaction PFAL, i.e., i want to move the data into a particular infotype only.

    Hi
    Make sure the structure that you are using in the upload is the same that you have defined in your LSMW and may be in the same order. Also the fields of the structure defined are correctly mapped to your Batch input recording.
    In this way you should not get any formatting error.
    Thanks
    Nikhil

  • Send IDoc through adapter IDoc_AAE

    Hi, guys!
    We have SAP PO version 7.4
    We need to setup the unloading of the IDoc from BI in PO
    I used the following sources:
    http://scn.sap.com/docs/DOC-31398 
    http://help.sap.com/saphelp_nw74/helpdata/en/34/66c81241874285851e2497aa6f0573/content.htm?frameset=/en/c2/91865252c84716b3b8be394851c9c0/frameset.htm
    http://scn.sap.com/docs/DOC-34155  
    http://scn.sap.com/people/william.li/blog/2011/05/04/configuring-pi-730-java-idoc-adapter
    http://scn.sap.com/community/pi-and-soa-middleware/blog/2013/08/05/connect-multiple-sap-ecc-clients-from-java-idoc-sender-adapter-by-resource-adapter-cloning
    http://scn.sap.com/community/pi-and-soa-middleware/blog/2010/10/21/pixi-pi-73-new-java-based-idoc-adapters-configuration-sender-receiver--teaser
    but it doesn’t work.
    I created Jco provider xi_idoc_default_pid (where PID  replaced the SID BI system)
    I created the RFC in PO for BI  xi_idoc_default_ destination _pid (ping successful)
    in inboundRA have in ProgrammID:  xi_idoc_default_pid
    in destination - xi_idoc_default_ destination _pid
    I created Sender channel (manual and default)
    I created in BI in sm59 RFC T
    I input   the program xi_idoc_default_pid , which was created in the first step, in field, and input
    gateway and host - my PO
    but the test does not pass the RFC.
    Could you please tell me,  what the problem is?
    I configured IDoc_AAE receiver. data arrives in BI, help me to setup up  send IDoc  from BI in PO
    Thanks.

    Hi,
    We also faced same issue for the RFC created from our ECC to SAP PO (netwaever 7.4 ) system. It is TCP/IP connection.
    there are 2 solutions:
    1) set gw/acl_mode parameter to 0 in ECC system resolved the issue. Ofcourse you need restart of Source(ECC) system. But it is not recommended in Prod systems
    2) Regenerated Reg info and sec info files in Source system(ECC) and created them in target system also and kept them in /usr/sap/SID/SYS/SCS01/data.
    The created files are given below for reference.
    Reginfo file:
    P TP=* HOST=*
    P TP=* HOST=*
    Secinfo file:
    P TP=* USER=* USER-HOST=* HOST=*
    P TP=* USER=* USER-HOST=* HOST=*
    BR
    Ravikiran

  • Sending IDoc through FunctMod - what if edidd-sdata size 1000

    There are several function modules to which we can send formatted IDoc data, and I am using one of them just fine (IDOC_INBOUND_SINGLE, if it matters).  However, one thing all of these FMs have in common is that they use the EDI_DD40 structure (or it's equivalent), which has an SDATA field of 1000 bytes.
    My problem comes from the need to use a standard SAP-delivered IDoc (MBGMCR01) that has a length of 1061 bytes.  This wouldn't necessarily be an issue as long as all of the data I needed was within the first 1000 bytes, but it's not.
    Any ideas on how to handle this?

    Ferry,
    I think this may be what you are suggesting, but in different words.  Either way, it would likely solve the problem, though not as cleanly as I'd like since now I've got to make changes to the MB_CREATE_GOODS_MOVEMENT BAPI.
    (1) create a new segment called ZZSDATA1
    (2) make this segment a child of the E1BP2107_GM_ITEM_CREATE segment
    (3) put the overflow information in the new segment
    I can't just add another field to the segment, with 1 byte or 1000 bytes.  All of the data for the segment has to fit within one 1000 byte sdata field.

  • Sending Idocs/tRFC through saprouter ?

    Hello,
    I understand that it is technically possible to send Idocs (tRFC) through a saprouter.
    But I couln't find any post/blog/articleof people who tried this setup.
    Anyone has tried to send Idocs through a saprouter ?
    Anything I should consider (besides adjusting the tRFC connexions) ?
    Thanks
    Raoul

    Hi Raoul,
    SAPROUTER allows or establishes a cross landscape/network communications. Eg: from your SAP system to SAP AG servers for remote support.
    As far as I know, there is not method/procedure to process IDOCs through saprouter.
    Thanks,
    Siva Kumar

  • IDOC through Proxies ABAP-PI  ports

    HI,
    Please suggest what are the pros and cons of sending IDOCS through proxies.
    When should we design like this ? 
    Thanks,
    Harsha

    First of all why u want to send IDOC through proxy as SAP provided all std IDOCs and IDOC approach to send data to XI,only u have to configure the things in R3 as well as XI.
    Cons will be u have to write the abap code for sending IDOCs and difficult to IDOC monitor.
    Just have a look at the below blog:-
    /people/ravikumar.allampallam/blog/2005/08/14/choose-the-right-adapter-to-integrate-with-sap-systems
    chirag

  • SEND IDOC using JCO(Priorty -HIGH)

    Hi, all
    I am facing to send IDOC through JCO(Java Connector Object). if some body have idea then reply me.
    In previous dovelopment i was using BAPI for save data . Now my requirement is IDOC.
    Regards,
    Sandeep
    Edited by: sandeep verma on Jan 2, 2009 2:41 PM
    Edited by: sandeep verma on Jan 2, 2009 2:41 PM

    hi sandeep,
    check this thread this will give the idea
    Re: Send an IDoc over JCo
    Sending Idoc to a java application
    Sending IDoc to java
    let me know  uneed any further info
    bvr

  • IS-Retail -Merchandise Hierarchy  IDOC creation through transaction WPMA

    During creation of IDOC for Merchandise Hierarchy through transaction code WPMA & selecting transfer material groups in other data. System create segment for all merchandise hierarchy available in system. If we need to transfer only specific merchandise hierachy for that company code in POS system this is not possible. Also we cannot transfer delta changes in Merchandise hierarchy. Each time we create IDOC you need to transfer all hierarchy nodes.
    Is there any transaction by which we can create IDOC for specific merchandise hierarchy.
    Pl suggest

    Thanks Vamsi
    This will help a lot for me but in this linkages will not be able to analyse by POS system. This will not tell which node is connected to others & their levels. This is gap between WPMA & WAFS. You can send changes with WPMU but changes in node is not getting transfer through this. Thanks for input

  • Creating sales order through BAPI - do not want to send idoc confirmation

    Hi guys!
    I'm creating a sales order using BAPI BAPI_SALESORDER_CREATEFROMDAT1. The system was cuztomized to send an idoc through an output type, so whenever this BAPI is executed an idoc is sent.
    My problem is that I do not want the Idoc to be created when using this BAPI.
    Is there a way not to use an output type when using the BAPI?
    Thanks in advance for your help!

    Use an output requirement that stops the proposal of the output.  You'll want to make sure that it works in both immediate and delayed modes, e.g., you can't use a field-symbol (or the KOMKBV1 user exit) for access to T180-TCODE or to the CALL_BAPI value in memory.   You might want to try the VBAK-ERNAM value, since you probably use a specific (non-dialog) user for the call.  Otherwise, use another field to identify a BAPI call and check that field in the requirement.

  • ALE Error while sending PO IDOC through EDI

    Hi Experts,
                      I am sending one PO IDOC through EDI but I am getting the following error:-
                      Message no. B1130.
                      "Too many recipients found for message type ORDERS in the ALE model"
                      How can I solve this error ? Please guide me in this regards as this is an
                      important issue with urgency.
    Thanks & Regards
    Jitendra Gujarathi

    Please check this discussion thread
    Re: Too many recipients found for message type in the ALE model

  • Unable to send PO through IDOC

    Hello!!
    Good Evening.
    I have a problem, while sending PO through idoc orders03, some idocs are going fine and some are stucking and i cross checked the succesful and failed idocs and came to know that, one segment is missing.
    How this has happened.
    Actually, E1EDKA1 is the segment.
    How to track this issue and rectify the mistake.
    Reply ASAP...!!

    It is the case that from sender system, you are sending data in a segment(we31) which you have not maintained in the idoc type(we30)  in the receiver system.there may be an extension which you have to add in the message type in the patner profile.
    doing this will completely resolve the issue.
    you may reprocess your i/b idoc from BD87 after maintainng the extension(we30)
    let me know if you have any doubt

  • How to send Outbound IDocs through an RFC-enabled FM

    Good day to all;
    A partner system (AS/400) wants to use a Java Connection to execute a RFC Function Module, in SAP, that will then return a collection of IDocs.
    Currently, the Function Module builds the IDocs, but I'm not exactly sure how to simply send those IDocs back to the AS/400.
    If anyone can help in this regard, that would be great.
    My current thoughts are to use Master_IDoc_Distribute, but then I imagine that requires a port configuration for the AS/400.  And if this is the case, does that mean that SAP will send the IDocs back itself instead of using the RFC interface?

    Hi Tavares,
    If you want to send outbound IDoc to AS/400 (external system), you need to setup file port (t/code WE21).
    For RFC interface, you need to setup RFC file port with RFC Destination (t/code SM59). In this case, SAP will send IDoc (individually or batch) to receiver system (AS/400). Perhaps you need a middleware for data transformation, if AS/400 does not perform data mapping for outbound IDoc. 
    For FTP interface, you need to setup flat/XML file port for outbound. then you can FTP the file to AS/400 later on.
    In addition to file port configuration, you also need to setup partner profile for outbound parameter (t/code WE20) and the distribution model (t/code BD64).
    Hope this will help.
    Regards,
    Ferry Lianto

  • Error in Sending IDoc to XI

    Hi Gurus,
    We are not being able to send Idocs from one of our Back-end SAP system. The Idoc status in we05 is successful but it doesn't reach XI. So we checked in SM58 in the Back-end R/3 system and there it shows the error:
    No Service For System  SAP*** , Client *** in Integration Directory
    We tried almost every possible setup
    -The System is defined in SLD and has the logical system name.
    -The Adapter Specific Identifiers are correct for the corresponding business system in ID
    -The RFC destination in R/3 system is defined.
    - Read through other similar threads in SDN about the similar problem.
    Do anyone have a more definite solution for this particular problem? The other R/3 systems are connected to XI system and all IDocs from those systems are arriving at XI.
    Waiting for your valuable advices!
    Regards,
    Suddha

    Hi All,
    We had eventually found the solution to this problem we were facing in sending IDoc, though I couldn't manage to update the thread with the solution. I think this would be a very helpful information for those who face similar problems.
    Let me describe the scenario first briefly,
    We are sending an IDoc (Idoc extension), from SAP system to XI and then send the XML payload as mail attachment to the receiver via receiver mail adapter. Since this is a cross company transaction, hence we have configured the scenario as a B2B in ID, which means we use Parties for both the sender and receiver.
    Now in the ID we had done all necessary configurations and used parties and services under Party. For the sender SAP system we assigned a Business System to Sender Partner, configured the Party Alternative Identifiers correctly. The ports were created in IDX1.
    On the other hand the SAP system was also configured successfully - including Partner Profile, Distribution List, RFC destinations and ports.
    In SLD we created Business System for the SAP system and in ID the Business System under party had the correct logical system name as Adapter Specific Identifiers.
    But after all these, the IDoc was not arriving at XI, though in R/3 the status of the IDoc was 03 in we02. When we checked in sm58 in R/3, it showed us the error message that "No Service For System  SAP*** , Client *** in Integration Directory".
    The cause to this problem was:
    We created (assigned from SLD) Business System only under Party (Sender), as this was a B2B scenario, and didn't create (assign) a Business System without Party, as we didn't need one at all in the scenario configuration. And this the reason behind this error. When an Idoc arrives at XI, before the Inbound IDoc adapter converts the IDoc to IDoc XML using IDoc metadata............it checks in Configuarion to see if any Service without Party (Busniess System) is defined for the Sender SAP System and Client (The SNDPOR and MANDT field values from IDoc Control header are taken as the SAP SID and Client). If it finds one it accepts the IDoc and starts the Normalization (Sender Party, Service......in the message header) and IDoc to XML conversion. If it cannot find an Service without Party in ID for sender system, it rejects the Idoc with the error message that we saw in sm58 in backend R/3 system.
    In this step the Service under Party doesn't help, because at this point the Inbound IDoc adapter can not deterimine the sender party.
    Hence for sending an IDoc from an SAP system to XI, we need to have an Service Without Party in ID, whether or not we require it in our actual Scenario Configuration, which is ofcourse not a case for the Reverse Scenario, ie Sending an IDoc into SAP system from XI.
    This is the similar with BC adapter as well. I was already aware about this behaviour of BC adapter from my past experience and this actually helped to troubleshoot this IDoc adapter problem.
    This was ofcourse a useful and new learning for me and hope would be helpful to others as well. Let me know if anyone has any doubts on this.
    Regards,
    Suddha
    Edited by: Suddhasatta Guha on Aug 28, 2008 1:03 PM

  • Error in Sending IDOC

    Hi,
    i am working with the Scenario IDOC to IDOC using middleware PI.
    Done with Whole Process .
    But when i Sending an IDOC through WE19 it went Succesfully(i checked it in WE05).
    But when i checked in SM58. then there is an error in sending my IDOC.
    Transaction IDX1: Port SAPETS, client 800, RFC destination contain error.
    Please let me know where might me the problem ??
    Thanks
    Deepthi

    Hi,
    Check the RFC destination connection from PI to ECC... looks like there is connection from PI to ECC to retrieve the metadata....
    HTH
    Rajesh

Maybe you are looking for

  • Adding fields 2 standard payment list program  (RFZALI20)  in F110 t-code

    hi frnds, it is a standard progrm using the logical database pfy. to retrive data. i have to add 5 more fileds  along with footer approved by and page break(shown below) to the output list. please help me with ur inputs. Header Data: *Note: Keep the

  • How can i install windows on new macbook air using remote drive on the bootcamp partition

    Hi all, I just purchased a new macbook air mid - 2011 with OSX-Lion installed on it. I wish to install Windows XP on the boot camp partition but have not purchased the external super drive. Is there some way that I can install windows on boot camp us

  • Product Category Hierarchy

    Dear All, i'm playing with Product Category Hierarchy in SRM 5.0. The Scenario i use is Extended Classic and in backend system we do not want to manage any Category Hierarchy. I created my SRM own Hierarchy starting from Product Category imported fro

  • Why Cant My Monitor playback 24fps Footage smoothley

    Hi All Ive been tearing my hair out today. My boss seems to thin I am able to preview an edit project, with a sequence setting of 24fps in my external Monitor. I have two monitors, one a broadcast CRT the other a Sony Bravio Plasma. I dissagree tho,

  • QuickTime Pro not recognized after having to reinstall

    I have my registration code, but I cannot register the copy as QUicktime Pro after having to UNinstall quicktime during the lastest iTunes update process. (I followed directions on apple.com how to correct an issue with my "audio configuration" which